Electromagnetic Flowmeters

Similar documents
Hazardous Area Zirconia Oxygen Systems

Installation Guide. EXGP Oxygen Analyzer System (ATEX) Interface Electronics Unit

Operating Guide IM/C1900-OGR Rev. J. C1900 Series Circular Chart Recorders

Zirconia Oxygen Analyzer

Zirconia Oxygen Analyzer

COMMANDER 1900 Series Circular Chart Recorders. Operating Guide. Recorder Versions COMMANDER deg F ABB Instrumentation

4600 Series Operating Instructions. Models 4623 and 4628 Conductivity Transmitters To Meet United States Pharmacopœia (USP 23) Regulations

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

instrumentation Hydrogen Analyzer Systems Unrivaled safety and technical expertise from the market leader in hydrogen measurement

Low Temperature Zirconia Oxygen Analyzer

Models 4623, 4628 & 5999/980 USP<645> Conductivity Analyzers

An Introduction to KC Controls Ltd

ZDT GP Series High Temperature Zirconia Oxygen Analyzer. Superior technology and quality from the world leader in oxygen measurement

Zirconia Oxygen Probe

Analyze IT Zirconia Oxygen Analyzer for Small Boiler Applications

COMMANDER 150. User Guide Universal Process Indicator A1

Instruction Manual. Model 6553 Series (ATEX) Gas Analyser Systems for Intrinsically Safe Hydrogen & Purge Gas Purity Measurement

Sodium Monitor. Data Sheet SS/8036_5. Model Wide measuring range (0.01 gkg 1 to 10mgkg 1 ) covers all power station applications

MagMaster MFE flowmeters feature an innovative multifrequency

ABB Instrumentation. Instruction Manual. Model 6553 Series of Intrinsically Safe Gas Analyser Systems for Hydrogen & Purge Gas Purity Measurement

User Guide IM/AK1/23 Rev. N. AK102 and AK103 Gas analyzer systems for Hydrogen-cooled alternators

User Guide. DATUM L150 Panel-Mounted Universal Level Indicator A1. ABB Instrumentation

Flash Condensing De-aerator Heads Installation and Maintenance Instructions

Analyze IT Monitors for Organic Pollution, Surrogate Color, THM Precursor Measurement and Coagulation Control

Rosemount 1595 Conditioning Orifice Plate

Variable Area Flowmeters Ratosight TM Flow Rate Indicators with Optional Ratolarm - 10A2235

AAO100 Dosing pump. Measurement made easy. Introduction

Kube Engineering. Industry Guide. Power Industry

Smart Sensors and Analytical Instruments Honeywell Solutions for Analytical Measurement and Control

Improving the Performance of Power Plants Worldwide

SPECIFICATIONS - DETAILED PROVISIONS Section Magnetic Flowmeters C O N T E N T S

PRODUCT CONFORMITY CERTIFICATE

EXFG Oxygen Analyzer System. Installation Guide. EXFG Probe. ABB Process Analytics

PROCESS CONTROL COURSES

Wallace & Tiernan Gas Feed Systems V2000 Chlorinator

Products Overview. Your trusted partner in process instrumentation

Tough as They Come. Ceramat. Retractable fittings for extreme conditions. With ceramic sealing to the process.

Hydrazine Analyzer Series 2171 Specifications

TD Series Temperature Transmitter with Local Display. One-piece sanitary construction 2-wire electronics High accuracy

Azbil introduction 2015

Instruction Manual. IT20K, IT100, IT300 and IT800 Inlet Traps. A Issue F. ITC800 Inlet Chemical Trap. ITD20K Inlet Desiccant Trap

DISTRIBUTION > HOUSING, HVAC > INSTALLATION > AIR INLET HOUSING

Multistage Centrifugal Blowers

Measurement & Analytics Measurement made easy. LLT100, LM80, and LM200 Lasers for level: Now everything is possible

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0077 Revision 1

CORPORATE OVERVIEW Canton Rd. Marietta, GA T: F: flwse.com

Pulp & Paper Solution. Pulp & Paper Solution. Instruments and Solution for Pulp & Paper Industry LF3BUSS03-00EN.

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Instrumentation and Analytical Sales, Service & Training

G-TECTA TM. Portable Gas Detection Instruments

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

For very low to medium/high conductivity: Where optimal performance is essential. INGOLD Leading Process Analytics

Size and rating wise typical Third Party Inspection certificates for the models of Valves

Transmitter Series. Intelligent Transmitter Series Tailor the Measurement to Your Needs INGOLD

Carbon Dioxide Sample-Draw Detector Operator s Manual

TR FLEXMAG 4050 C Electromagnetic flow meter for single use processes

Rosemount 372. HF Resistant ph sensor. Quick Start Guide LIQ-QSG-372 Rev. C June 2017

Sieger Apex. Flexibility that meets your requirements

Operating Instructions. Electromagnetic Flowmeter Flowcont FN Hygienic version Flowcont LN

M-Switch Float Operated Liquid Level Switch

operations, Environmental & Instrumentation engineering solutions to the Commercial & Industrial segment in the Middle East. ARE

805QS Pressure Switch-Transmitter

PRODUCT CONFORMITY CERTIFICATE

TH450A-CRB TH550A-CRB THP550-CRB/TS3000

Warning Caution. Safety Precautions (Be sure to read these precautions before using our products.)

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

Tasmanian supplier of high quality instrumentation, control and electrical equipment for all industries. Mining, Food and Beverage, Water and

Transmitter OCX 4400 THE LATEST BREAKTHROUGH FOR COMBUSTION FLUE GAS ANALYSIS. Product Data Sheet PDS A01 February, 2001

FRL 10 Centrifugal blowers

CORPORATE OVERVIEW Canton Rd. Marietta, GA T: F: flwse.com

Circular Chart Recorder

FLT93 Installation, Operation and Troubleshooting Guide

Hodge Clemco Ltd. MJC Mini Cartridge Filters Owners Manual. TSOM 556 Date of issue 13/07/04. Hodge Clemco Ltd

itemp RTD TMT 187 itemp TC TMT 188 Temperature head transmitter

Sensor Interface Module Installation/Operation Instructions

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

Northvale Korting Global Contacts

Torqueflow Sydex. Fluid Management. K Range Pumps

Dew-Point Transmitters and Instruments

B.I.C.A Built-In Coffee Appliance

A New Standard of Excellence

No.THD51E To prevent accidents arising from the use of this product, please ensure the operator using it receives this manual.

Installation & Operating Instructions

Multistage Centrifugal Blowers

Steam and Water Analysers

Combustible Gas Sample-Draw Detector Operator s Manual

Note: Please provide valve serial number (stamped on cover of valve) when ordering parts. Tempered Water Outlet. Hot Water Inlet.

AutoTest VSR (VSR-AT) (EU) Vane Type Waterflow Alarm Switch With Electronic Retard and Auto Test Feature

PURSense Sanitary Flange Conductivity Sensors

Endura AZ40 Oxygen and carbon monoxide equivalent (COe) analyzer

Emerson Fieldbus Technology used to Upgrade Temperature Monitoring at Largest UK Coal Fired Power Station

Model 6050-Series. PumpAgents.com - buy pumps and parts online SELF-PRIMING PUMPS. Model 6050-Series

/8 DIN Level Indicator

Electronic steam boiler controls

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Installation, Operation and Maintenance Guide AP3900 Series Thermostatic Mixing Valves

ISIS SAFETY SYSTEM Installation guide

THERMAL BUILDING SOLUTIONS EN-TraceTekTTSIM1A-IM-H /16

Aluminum Heating Mantles

17 U.S. gallon portable low profile drain with electric pump

Transcription:

Instruction Manual BOOK 2 Mechanical Installation IM/MMAMBK2_6 Electromagnetic Flowmeters MagMaster TM AquaMag

ABB The Company We are an established world force in the design and manufacture of instrumentation for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. EN ISO 9001:2000 RE GISTERED Cert. No. Q 05907 EN 29001 (ISO 9001) We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. Lenno, Italy Cert. No. 9/90A Stonehouse, U.K. The UKAS Calibration Laboratory No. 0255 is just one of the ten flow calibration plants operated by the Company and is indicative of our dedication to quality and accuracy. 0255 Use of Instructions Warning. An instruction that draws attention to the risk of injury or death. Note. Clarification of an instruction or additional information. Caution. An instruction that draws attention to the risk of damage to the product, process or surroundings. Information. Further reference for more detailed information or technical details. Although Warning hazards are related to personal injury, and Caution hazards are associated with equipment or property damage, it must be understood that operation of damaged equipment could, under certain operational conditions, result in degraded process system performance leading to personal injury or death. Therefore, comply fully with all Warning and Caution notices. Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of the Marketing Communications Department. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding. 2. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

CONTENTS 1 INTRODUCTION BOOK 2 MECHANICAL INSTALLATION Contents Page SAFETY MEASURES... 1 1 INTRODUCTION... 1 This book describes the mechanical installation of MagMaster TM and AquaMag ranges of electromagnetic flowmeters. Attention to safety measures, installation conditions and general precautions will ensure trouble free operation. 2 INSTALLATION CONDITIONS... 2 3 INSTALLATION... 4 3.1 Transmitters... 4 3.1.1 Location... 4 3.1.2 Mounting... 4 3.2 Sensors... 5 Note. Not all available versions are approved. Mechanical Installation covers general aspects of both approved and non-approved products. Warning. Installation and maintenance must only be carried out by suitably trained personnel. HAZARDOUS AREA DESIGNATION ON THE EQUIPMENT LABEL MUST BE SUITABLE FOR THE INTENDED DUTY AND LOCATION. All relevant sections of this manual must be read before selecting a location. Safety requirements of this equipment, any associated equipment, and the local environment must be taken into consideration. The installation and use of this equipment must be in accordance with relevant national and local standards. Warning. Mating Hygienic end connections, clamps and supplied gaskets as ordered may have a lower pressure and temperature limit than that shown on the sensor data label. 1

2 INSTALLATION CONDITIONS Avoid Widely Varying Temperatures Away from Dripping Fluids or Spillage Vibration-free Location Shade from Heat Fig. 2.1 Environmental Conditions >2 x pipe dia. >5 x pipe dia. minimum minimum Flow Direction Typical Installation Flow Direction Fig. 2.2 Flow Conditions Fluid Level Allow room to read display Location Lagging (High Temperature Version) Avoid Heat Near Linings Fig. 2.3 Location and General precautions Backfill Metal Protection Plate Supports Supports Under Ground Fig. 2.4 Location and General Precautions Above Ground 2

2 INSTALLATION CONDITIONS 50 C (120 F) Max. -20 C ( 4 F) Min. 80 C (176 F) Max. 60 C (140 F) Max. 10 C (14 F) Min. 20 C ( 4 F) Min. Fig. 2.5 Cable Routing Fig. 2.7 Within Temperature Limits 1.5m (60in) IP68 (NEMA 6) Fig. 2.6 Cleaning Precautions for Hygienic Sensors IP65 (NEMA 4) Fig. 2.8 Within Environmental Rating 3

3 INSTALLATION 3.1 Transmitter 3.1.1 Location Select a location where the transmitter unit will not be subject to undue vibration or exposed to environmental conditions beyond the degree of protection. The location chosen should be free from harsh electrical noise such as that from adjacent equipment, cables, r.f.i. or e.m.i. 3.1.2 Mounting 162mm (6.35in) >43567 Ltr 12.328Ltr/s Caution. Do not overtighten fixings, especially on an uneven surface. 214mm (8.43in) 232mm (9.13in) (Fixing Centres) Providing that free access is available to allow the display to be viewed as required, the unit can be either wall mounted or panel mounted with masonry fixings or nuts and bolts respectively via the fixing holes provided. 32mm (1.26in) 150mm (6in) 69mm (2.72in) (Fixing Centres) Allowance for cable bends 200mm (8in) 100mm (4in) Fixing Centres 2 Holes, 8mm (0.32in) Diametet 3 Fixing Holes, 6.5mm (1/4in) Diameter Fig. 3.2 MagMaster Transmitter Mounting Details 300mm (12inn Allowance for cable bendd 200mm (8in) Fig. 3.1 AquaMag Transmitter Mounting Details 4

3 INSTALLATION 3.2 Sensors Caution. Do NOT exceed the maximum working pressure marked on the equipment. Use stainless steel (austenitic) bolts, studs and nuts for flanged sensors below 200mm bore. Sensor size Nominal Bore (mm) (in.) 50 50 to 300 > 300 2 2 to 12 >12 Maximum Misalignment (mm) (in.) 1.5 2 4 0.06 0.08 0.16 10 TYPICAL 45 MAX. Sensor Electrodes horizontal Fig. 3.3 Sensor Alignment Fig. 3.4 Sensor Position Mild steel clamping studs Fit full face gaskets on wafer type sensors HYGIENIC SENSOR Gasket orientation Fit Gaskets Fit gaskets as required Fit adapters and gaskets as supplied Note. Ensure gaskets are fitted correctly as shown. Correct Void created Obstruction and void created Flow obstructed FLOW FLOW EDDIES FLOW EDDIES FLOW EDDIES Gasket Same Size as Pipe Gasket too Large Gasket Misaligned Gasket too Small Fig. 3.5 Gasket Installation 5

3 INSTALLATION Caution. Do not rely on flange bolts or studs for electrical connection. Information. See ELECTRICAL INSTALLATION book for ground wiring. 3.2 Sensors Insulating Sleeve and Washer (not provided) Gasket Gasket Grounding Ring Fig. 3.6 Mounting in Pipelines with Cathodic Protection Grounding Ring Upstream Flange Preferably FLOW Fig. 3.7 Mounting in Plastic Pipelines Sensors without Grounding Electrodes 6

NOTES 7

NOTES 8

PRODUCTS & CUSTOMER SUPPORT Products Automation Systems for the following industries: Chemical & Pharmaceutical Food & Beverage Manufacturing Metals and Minerals Oil, Gas & Petrochemical Pulp and Paper Drives and Motors AC and DC Drives, AC and DC Machines, AC motors to 1kV Drive systems Force Measurement Servo Drives Customer Support We provide a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. United Kingdom ABB Limited Tel: +44 (0)1453 826661 Fax: +44 (0)1453 827856 United States of America ABB Inc. Tel: +1 (0) 755 883 4366 Fax: +1 (0) 755 883 4373 Controllers & Recorders Single and Multi-loop Controllers Circular Chart, Strip Chart and Paperless Recorders Paperless Recorders Process Indicators Flexible Automation Industrial Robots and Robot Systems Flow Measurement Electromagnetic Flowmeters Mass Flow Meters Turbine Flowmeters Flow Elements Marine Systems & Turbochargers Electrical Systems Marine Equipment Offshore Retrofit and Refurbishment Process Analytics Process Gas Analysis Systems Integration Transmitters Pressure Temperature Level Interface Modules Valves, Actuators and Positioners Control Valves Actuators Positioners Water, Gas & Industrial Analytics Instrumentation ph, conductivity, and dissolved oxygen transmitters and sensors ammonia, nitrate, phosphate, silica, sodium, chloride, fluoride, dissolved oxygen and hydrazine analyzers. Zirconia oxygen analyzers, katharometers, hydrogen purity and purge-gas monitors, thermal conductivity. Client Warranty Prior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification. Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation: 1. A listing evidencing process operation and alarm logs at time of failure. 2. Copies of all storage, installation, operating and maintenance records relating to the alleged faulty unit.

ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in UK (03.04) ABB 2004 IM/MM/AMBK2 Issue 6 ABB Limited Oldends Lane, Stonehouse Gloucestershire GL10 3TA UK Tel: +44 (0)1453 826661 Fax: +44 (0)1453 829671 ABB Inc. 125 E. County Line Road Warminster PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183