Linea HE. High efficiency combi boiler. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Similar documents
AquaNova. Water heater. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Mynute. Standard efficiency system boiler 12e - 16e - 20e. Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

iheat 25c iheat 30c iheat 35c

User's Instructions. Alpha CB50

User's Instructions. Alpha CD24C/32C. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

Baxi Maxflow Combi WM

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Format System 25 HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Baxi Maxflow Combi FS

With a power output ranging from 13kW to 24kW, they provide the flexible answer for the majority of traditional installation scenarios.

Baxi Combi 80Eco. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

FORMAT DGT HE. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

User's Instructions. Alpha CD25X/28X. Range of Wall Mounted, Fan Assisted, Room Sealed, Gas Fired, High Efficiency Condensing Combination Boilers

PLEASE LEAVE THIS INSTRUCTION WITH THE USER. Ecomfort 30 HE. User instructions

MURELLE EV HE 25/55-30/55

Performa 24. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

PLEASE LEAVE THIS INSTRUCTION WITH THE USER ECOMFORT PLUS 25 HE. User instructions

Baxi Bahama 100. Gas Fired Wall Mounted Combination Boiler. User s Operating Instructions

MERIDIAN HE 30 C. User instructions. Please read the Important Notice within this guide regarding your boiler warranty

Baxi System 100 HE Plus. User s Operating Instructions. Wall Mounted Powered Flue Condensing Gas Fired Central Heating Boiler

Compact 24 SE. Standard efficiency combi boiler. Users Instructions. Installation & Servicing Instructions. GC No

Baxi Combi 133 HE Plus Baxi Combi 100 HE Plus Baxi Combi 80 HE Plus. User s Operating Instructions

USER GUIDE VOGUE MAX SYSTEM

USERS GUIDE. Esprit eco 24, 30. For installation guide see reverse of book

User Guide and Important Warranty Information. Suprima HE. Condensing Central Heating Boiler. Please read this document and keep it safe.

USER GUIDE VOGUE COMBI GEN2 C26 C32 C40

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

The guarantee on this appliance is valid for 12 months from the first day of installation.

i 24, i 30, i 35 combination boilers USER GUIDE For Installation Guide see reverse of book UIN A05 October 2017

Vision C. High eficiency combi boiler. Users Instructions. Installation & Servicing Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER

Osprey 2 CFL

USERS GUIDE 24, 30. For installation guide see reverse of book

System s30. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS SYSTEM BOILER

24CDi, 28CDi & 35CDi II COMBI

Open Vented Condensing Boilers

Logic+ Combi

E-COMBI EVO E-SYSTEM EVO

Combi Eco Elite Range. User s Guide and Important Warranty Information

Unica i28 - i32 - i36 High effi ciency combi boiler

End User Manual ACO 35 MFFI COMBI

Compact A. High efficiency combi boiler. Users Instructions. Installation & Servicing Instructions

USERS GUIDE. LOGIC+ Combi 24, 30, 35

Heat 45 & 55. User Instructions FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

ir-range 8G /03.15 Changes reserved.

USER GUIDE LOGIC HEAT H

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

Baxi Megaflo System HE IE Range. User s Operating Instructions & Important Warranty Information. Gas Fired Wall Mounted Condensing Boiler

USER GUIDE. IMAX XTRA EL kW. For Installation Guide see reverse of book

User Guide and Important Warranty Information. Promax System HE Plus A Range. Condensing System Boiler

Compact A High effi ciency combi boiler Users Instructions Installation & Servicing Instructions Compact A 25 G.C. N Compact A 29 G.C. N 47-

Baxi Combi 105 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Boiler

Ultracom cxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

E-Combi One E-System ONE

evolve High efficiency combi boiler Users Instructions Installation & Servicing Instructions

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Powermax HE 85, 115 & 150 Litre Condensing Boilers with Integrated Hot Water Storage

Greenstar 12i/24i System

Combi C30 & C35. User Guide FAN POWERED HIGH EFFICIENCY MODULATING DOMESTIC CONDENSING GAS COMBINATION BOILER

WARMCAIR. Condensing Air & Water Heater. High Efficiency Downflow Condensing Air & Water Heater USERS INSTRUCTIONS

Planet Super4F.S. User Instructions

User Guide and Important Warranty Information. Suprima HE Range. Condensing Central Heating Boiler. You can rely on

For the owner. Operating manual. ecotec plus 937. Gas condensing storage combination boiler VUI

Performa 24 Eco HE. User Guide and Important Warranty Information. Condensing Combination Boiler

GREENSTAR HIGHFLOW 440/550CDi

SERIES. End User Manual ACO 27 MFFI G.C.N: ACO 32 MFFI G.C.N: ACO 27 RFFI G.C.N: ACO 32 RFFI G.C.

24/30/38. E-Combi. CONDENSING WALL HUNG COMBINATION BOILER G.C.N : (24 kw) G.C.N : (30 kw) G.C.N : (38 kw)

GB24 & GB30. User Manual

Installation & User s Instructions

Ultracom hxi. Instructions for Use. High Efficiency Condensing System Boilers. To b e l e f t w i t h t h e u s e r.

Greenstar 12i system / 24i system

2 Minimiser SE - User's

User Guide. Promax SL Condensing Central Heating Boiler

TABLE OF CONTENTS. IMPORTANT Please read this manual carefully.

/2005 GB(EN) For the user. Wall-mounted condensing gas combi boiler Buderus /C, /C

User s Operation Instructions & Important Warranty Information

Easi-Heat Plus S. High efficiency system boiler. Users Instructions. Installation & Servicing Instructions

User Guide. Main Eco Elite Combi Condensing Central Heating Boiler

Domestic Gas Boilers. UNICA i n. VISION C n. MYNUTE i n. VISION S n. MYNUTE VHE n. BeSMART CONTROL n

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

/2010 US/CA

User Guide. Duo-tec Combi LPG. Gas Fired Wall Mounted Condensing Combination Boiler

VIESMANN. Operating instructions VITODENS 100. for system users. Heating system with control unit for constant temperature operation

British Gas 330+ High Efficiency Condensing Boiler. Instructions for Use. To b e l e f t w i t h t h e u s e r. British Gas Service Tel:

AVANT DGS. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Please keep these instructions in a safe place. If you move house, please hand them over to the next occupier.

Domestic heating solutions

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

Instructions for Use Installation and Servicing

Maximiser SE. USER S INSTRUCTIONS Natural gas only INSTALLER: TELEPHONE:

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

Residential Gas Condensing Boiler Greenstar ZBR16/21/28/35/42-3A... ZWB28/35/42-3A...


Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

User s Operation Instructions & Important Warranty Information. High-efficiency wall-hung boilers Baxi Avanta Heat Only 15h - 18h - 24h - 30h

Operating instructions

Greenstar 24i junior / 28i junior

User Manual FLOWMAX-90. for model. Condensing water heater 85,000 BTU. Installation, operating, commissioning and maintenance instructions.

GREENSTAR HIGHFLOW 440/550CDi

Alpha CombiMax 350 and 600

Transcription:

Linea HE High efficiency combi boiler Users Instructions THESE INSTRUCTIONS TO BE RETAINED BY USER Vokèra is a licensed member of the Benchmark scheme which aims to improve the standards of installation and commissioning of domestic hot water systems in the UK.

Contents Introduction Page Dear customer 2 Do s and don t s 2 Things you should know Page 1.1 Gas appliances 4 1.2 Electrical supply 4 1.3 Guarantee registration card 4 1.4 Benchmark log book 4 1.5 How does it work? 4 1.6 Dimensions 4 1.7 Clearances required 4 1.8 Frost protection system 4 1.9 Additional controls 4 How to... Page 3.1 Top-up the system pressure 8 3.2 Reset the appliance 8 3.3 Shut down the system for short periods 8 3.4 Shut down the system for long periods 8 3.5 Care for the appliance 8 3.6 Regulate the hot water temperature 8 What if... Page 4.1 I suspect a gas leak 9 4.2 I have to frequently to top-up the system 9 4.3 The reset light is on 9 4.4 The appliance is due its annual service 9 4.5 I need to call an engineer 9 Getting started Page 2.1 Before switching on 5 2.2 Appliance controls 5 2.3 Lighting the boiler 5 2.4 Adjusting the operating temperatures 6 2.5 Digital display 6 2.6 Fault code table 6 2.7 Information mode 7 INTRODUCTION Dear Customer Your Linea HE boiler has been designed to meet and exceed the very latest standards in gas central heating technology, and if cared for, will give years of reliable use and efficiency. Please therefore take some time to read these instructions carefully. Do s and Don t s Do ensure that the system pressure is periodically checked Do ensure that you know how to isolate the appliance in an emergency Do ensure that you are familiar with the appliance controls Do ensure that your installer has completed the appliance log book Do not attempt to remove the appliance casing or gain internal access Do not hang clothes etc. over the appliance Do not forget to have the appliance serviced annually. 2 Linea HE

Fig. 1 1 2 3 4 5 1= central heating temperature control 2= ON/OFF/RESET button 3= MODE button 4= INFO button 5= hot water temperature control Symbols description Summer Spring Autumn Winter current water pressure outside sensor current appliance temperature error code central heating temperature bar current mode of operation burner on hot water temperature bar service request reset frost protection on insufficient water pressure Linea HE 3

THINGS YOU SHOULD KNOW 1.1 GAS APPLIANCE Gas Safety (Installations and Use) Regulations. In the interests of your safety and that of others it is a legal requirement that all gas appliances are installed and correctly maintained by a competent person and in accordance with the latest regulations. 1.2 ELECTRICAL SUPPLY Please ensure that this appliance has been properly connected to the electrical supply by means of a double pole isolator or un-switched socket, and that the correct size of fuse (3 AMP) has been fitted. Warning: this appliance must be earthed! 1.3 GUARANTEE REGISTRATION CARD Please take the time to fill out your guarantee registration card. The completed warranty card should be posted within 30 days of installation. 1.4 BENCHMARK LOG BOOK The Benchmark Log Book is supplied with your boiler. This important document must be completed during the installation/commissioning of your boiler. All CORGI Registered Installers carry a CORGI ID card and have a registration number. Both should be recorded in your Benchmark Log Book. You can check your installer by calling CORGI direct on 01256 372300. Failure to install and commision the appliance in accordance with the manufacturers instructions may invalidate the warranty. This does not affect your statutory rights. 1.5 HOW DOES IT WORK? Your Linea HE boiler is a high efficiency combination boiler, which supplies heated water to your radiators and hot water to your taps. The central heating is controlled via a time clock and/or any thermostats that your installer may have fitted. The boiler will light when a hot water outlet (a tap) is opened. The boiler may also function periodically to pre-heat the hot water heat exchanger. The Linea HE boiler lights electronically and does not have a pilot light. In the unlikely event of a fault developing with your boiler, the supply of gas to the burner will be terminated automatically. 1.6 DIMENSIONS HEIGHT WIDTH DEPTH 1.7 CLEARANCES REQUIRED ABOVE BELOW SIDES FRONT 845 mm 453 mm 390 mm 150 mm 120 mm 12 mm 600 mm 1.8 FROST PROTECTION SYSTEM The Linea HE is equipped with a built-in frost protection system, this enables the boiler to override the time controls if switched off and operate the burner and/or pump, should the temperature drop below 6 C. Please note that the frost protection system is designed to protect the appliance only, should frost protection be required for the central heating system, additional controls may be required. NOTE The frost protection system is reliant on the appliance having a permanent electrical supply, and being in a non-fault condition. 1.9 ADDITIONAL CONTROLS Additional controls such as an external temperature sensor kit or under floor heating safety thermostat are available as optional accessories for this appliance. You should consult your installer and/or the supplementary instructions supplied, on their use (if installed). 4 Linea HE

GETTING STARTED 2.1 BEFORE SWITCHING ON Before switching the appliance on please familiarise yourself with: how to isolate the appliance from the gas, water and electricity supplies; how to check and top-up if necessary the system water pressure; any external thermostats/time switches and their functions; the appliance controls. 2.2 APPLIANCE CONTROLS (see fig. 1) The appliance controls are concealed behind the front cover. To gain access to the controls simply push-in the release button to open the cover. The appliance is equipped with a simple control panel that can be used to alter or control the following functions: ON/OFF selection; mode of operation; the outlet flow temperature to the central heating system; the outlet temperature for domestic hot water. In addition, the large LCD display shows the status of the appliance: current mode of operation; current appliance temperature; current temperatures selected; current system water pressure. The system water pressure display shows the current pressure of the system, andwhen the appliance is operating the display may rise or fall, this is quite normal. The minimum permissible level for the safe and efficient operation of the appliance is 0.6 BAR. Should the pressure fall below 0.6 BAR, the boiler may lockout. Depending on the type of controls specified by your installer you may have an external time clock or programmer fitted, please refer to the instructions supplied with such. 2.3 LIGHTING THE BOILER Ensure the gas and electrical supply to the boiler are turned on. Using figure 1 as a guide, locate and press the ON/ OFF selection button if the appliance isn t already switched on. The boiler will now go through a selftest sequence. On completion of the self-test sequence, the boiler will be ready to provide heating and/or hot water if required. 2.3.1 MODES OF OPERATION When the appliance is switched on one of four modes of operation can be selected: summer; spring; autumn; winter. Summer When the summer mode is selected, the appliance will respond to requests for Domestic Hot Water (DHW). In the summer mode the TSC (Temperature Stability Control) function is active. All heating requests will be ignored. Spring When the spring mode is selected, the appliance will respond to requests for Domestic Hot Water (DHW). All heating requests will be ignored. Autumn When the autumn mode is selected, the appliance will respond to requests for DHW and/or heating. During the autumn mode, the SARA function (Automatic Temperature Control), and the TSC (Temperature Stability Control) are active. Winter When the winter mode is selected, the appliance will respond to requests for DHW and/or heating. During the winter mode, the booster function and pre-heat function are active. 2.3.2 FUNCTIONS TSC: when the TSC function is active (summer/autumn) the appliance may over-ride the selected DHW temperature in order to maintain temperature stability. SARA: when the SARA function is active (autumn) and the selected heating temperature is set between 55 o 65 o C, the appliance will automatically raise the heating outlet temperature when the selected set temperature cannot be achieved or maintained. BOOSTER: when the booster function is active (winter), the appliance will automatically raise the heating outlet temperature when the selected set temperature cannot be achieved or maintained. PRE-HEAT: when the pre-heat function is active (winter), the appliance will periodically heat the DHW heat exchanger to reduce waiting time during DHW requests. FROST PROTECTION: the frost protection function is active at all times even when the appliance ON/OFF selector is at OFF. Should the temperature fall to 6 o C, the boiler will operate to reduce the risk of frost damage. ANTI-BLOCK: the anti-block function is active at all times even when the appliance ON/OFF selector is at OFF. Should the appliance be inactive for 19-hours, both the pump and divertor valve actuator will be energised for a short period to reduce the risk of component seizure. NOTE The frost protection and anti-block functions are reliant on the appliance having a permanent electrical supply, and being in a non-fault condition. 2.3.3 HEATING REQUEST When there is a demand for heating via the time clock etc, the boiler will go through an ignition sequence, whereby the burner will light. When the appliance reaches the set temperature, the burner will go off for minimum period of approximately 5 minutes. When the programmer/time clock or external thermostats heating request has been satisfied, the appliance will switch off automatically. Linea HE 5

2.3.4 HOT WATER REQUEST When a hot water outlet or tap is opened, the boiler senses water flow and initiates an ignition sequence. The boiler will modulate the output according to the temperature required, when the hot water request has been satisfied, the boiler may continue to operate if the pre-heat function is active. NOTE If the appliance fails to ignite during the ignition sequence, it will re-attempt ignition several times before going to a lockout condition. Should this occur, please allow a period of two minutes before re-setting. 2.4 ADJUSTING THE OPERATING TEMPERA- TURES (see fig.1) The temperature selector knobs can be rotated to increase or decrease the currently selected temperatures. The display will show any increase or decrease relative to the corresponding selector knob. 2.4.1 ADJUSTING THE CENTRAL HEATING TEM- PERATURES (see fig.1) If an outside temperature sensor is not connected to the boiler the heating selector can be adjusted between 20 C and 80 C. If an outside temperature sensor is connected to the boiler ( on) the central heating temperature is automatically calculated from the boiler in order to have a room temperature of 20 C. It is possible to adjust this value with the heating selector knob from - 5 C up to + 5 C. 2.4.2 ADJUSTING THE HOT WATER TEMPERA- TURES (see fig.1) The hot water selector can be adjusted between 35 and 60 C. 2.5 DIGITAL DISPLAY The digital display shows the current mode of operation and/or status of the boiler. Should a fault develop, the display will show a unique fault code that can be used to help rectify the cause of the fault. Should a fault code be displayed, check the fault code table to identify the cause and course of action to take. Always wait 2-minutes before pressing the reset button. 2.6 FAULT CODE TABLE Code 10 11 12 13/14 20/21/22 23/31 30 32/34 33/35 40 41 42 50/51/52 53/54/55/56 60/61 62 70/72/74 71/73 75/76 77 80/90/91 92 93/95 94 Reason Ignition anomaly No flame detected Restarts ignition Wiring fault Heat exchanger temperature too high Wiring fault Wiring fault Fan fault Fan fault Low water pressure Low water pressure Pressure gauge fault Internal fault Internal fault Sensor fault Wiring fault Temperature anomaly Temperature anomaly Wiring fault Temperature anomaly Internal fault Condense pipe blocked Condense pipe blocked Wiring fault Action required Reset appliance, if fault continues, call engineer Wait Wait Wait Wait Check/restore system pressure and reset Check/restore system pressure Reset appliance, if fault continues, call engineer Reset appliance, if fault continues, call engineer Wait Wait 6 Linea HE

2.7 INFORMATION MODE The appliance keypad can be used to display certain information on the working status of the boiler. Push the Info button ( ) to enter the info menu (fig. 2). The following information are shown pushing subsequently the button: Info 1 outside temperature (only if outside sensor connected) (fig. 3) Info 2 water pressure (fig. 4) Info 3 CH temperature set (fig. 5) Info 4 DHW temperature set (fig. 4.6). Fig.4 Fig. 5 Fig. 2 Fig. 3 Fig. 6 Linea HE 7

HOW TO... 3.1 HOW TO TOP-UP THE SYSTEM PRESSURE (fig. 4) The system pressure must be checked periodically to ensure the correct operation of the boiler. The display should ideally be reading between 0.6 (minimum) and 1.5 (maximum) when the boiler is in an off position and has cooled to room temperature. If the pressure requires topping-up use the following instructions as a guide. Locate the filling valve connections (beneath the boiler). Attach the filling loop to both connections. Open the filling valve slowly until you hear water entering the system. Close the filling valve when the displayed pressure (on the boiler) reads between 1 and 1.5. Remove the filling loop from the connections. 3.2 HOW TO RESET THE APPLIANCE When the display is flashing, or when the reset icon is shown, the appliance will require to be reset manually. Before resetting the boiler ensure that the displayed pressure is indicating the correct level. Allow a period of two minutes to elapse before pressing the reset button. IMPORTANT If the appliance requires to be reset frequently, it may be indicative of a fault, please contact your installer or Vokera Customer Services for further advice. 3.3 HOW TO SHUT DOWN THE SYSTEM FOR SHORT PERIODS The system and boiler can be shut down for short periods by simply turning the time clock to the off position. It is also advisable to turn off the main water supply to the house. C/H flow valve Fig. 4 C/H return valve Gas cock Hot water outlet Cold water inlet stopcock/filling valve Filling loop Safety valve outlet normal operating position 3.4 HOW TO SHUT DOWN THE SYSTEM FOR LONG PERIODS If the house is to be left unoccupied for any length of time especially during the winter the system should be thoroughly drained of all water. The gas, water, and electricity supply to the house should also be turned off. For more detailed advice contact your installer. 3.5 HOW TO CARE FOR THE APPLIANCE To clean the outer casing use only a clean damp cloth. Do not use any scourers or abrasive cleaners. 3.6 HOW TO REGULATE THE HOT WATER TEM- PERATURE Usually your installer will have adjusted the hot water output to suit your requirements, however if you would like to adjust the outlet temperature, please follow the instructions in section 2.4. NOTE If you find that the hot water temperature is still insufficient, try reducing the flow of water through the tap. Fig. 5 closed position filling position 8 Linea HE

WHAT IF... 4.1 WHAT IF I SUSPECT A GAS LEAK If you suspect a gas leak, turn off the gas supply at the gas meter, and contact your installer or local gas supplier. I you require further advice please contact your nearest Vokera office. 4.2 WHAT IF I HAVE FREQUENTLY TO TOP-UP THE SYSTEM If the system regularly requires topping-up, it may be indicative of a leak. Please contact your installer and ask him to inspect the system. 4.3 WHAT IF THE RESET LIGHT IS ON If the reset icon is shown, it indicates that the boiler has failed to ignite or has overheated, when this happens the boiler automatically shuts down and requires to be reset manually (see 3.2). 4.4 WHAT IF THE APPLIANCE IS DUE ITS AN- NUAL SERVICE Advice for tenants only Your landlord should arrange for servicing. Advice for homeowners Please contact Vokera Customer Service (0870 333 0220 (UK) or 05655057 (ROI) if you would prefer a Vokera service engineer or agent to service your appliance. Alternatively your local CORGI registered engineer may be able to service the appliance for you. 4.5 WHAT IF I NEED TO CALL AN ENGINEER If you think your boiler may have developed a fault please contact your installer or Vokera Customer Services (0870 333 0220 (UK) or 05655057 (ROI) have all your details to hand including full address and postcode, relevant contact numbers, and your completed appliance log book. Linea HE 9

NOTE 10 Linea HE

Linea HE 11

Cod. 10026492-10/05 - Ed. 2 Registered address: Vokèra Ltd Borderlake House Unit 7 Riverside Industrial Estate London Colney Herts AL2 1HG enquiries@vokera.co.uk www.vokera.co.uk www.vokera.ie Sales, General Enquires T 0844 391 099 F 0844 391 0998 Vokèra Ireland West Court, Callan Co Kilkenny T 056 7755057 F 056 7755060 Vokèra Limited reserve the right to change specification without prior notice Consumers statutory rights are not affected. A Riello Group Company. Company Reg No: 1047779