Quick Setup Guide for IntelliAg Model NTA607HD

Similar documents
OPERATOR S MANUAL. Safety Notices... 1 Disclaimer... 1

2012 Toolbar & NH3 Operators Manual

TABLE OF CONTENTS. Pre-Operating Preparation... 5 Pre-Defined Constants... 5 Fill Disk... 5

LOUP II DRILL MONITOR OPERATION MANUAL. SOFTWARE v45

Operators Manual. E15 Seeder Console Air Seeder Monitor A600 R1.3 V2.0.18

Introduction... 1 System Overview... 1 System Diagram... 2

The Vanguard System TM VM-2900 Air Seeder Monitor. Operator s Manual

1-16 Row Population Monitor

5.6 "IN MOTION" CONDITION

Introduction... 1 System Overview... 1 System Diagram... 2

Evaluation Report 625

User s Guide GPL 750

PAC-2750 ELECTRIC COOLING FAN CONTROLLER

C-TRAC3 COMMUNICATION MANUAL FOR. BACnet NOVEMBER 2010 TO JANUARY 2014 USA HEAD OFFICE AND FACTORY

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

SCAN200E USER S MANUAL

Operation Manual. Model 600BB. Moisture Sensor Kit for Large Square Balers For New Holland BigBaler and Case IH LB BB-OPR 5/14

1592 In Cab Monitor (ICM) QUICK START GUIDE

PM100/PM100E PLANTER MONITOR. Operator s Manual

Rev Pulse Modulating Anti- Sweat Control (PMAC II) Installation and Operation Manual

PC15CP PUMP CONTROLLER

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

CELLTROL II BIOREACTOR CONTROL SYSTEM OPERATIONS MANUAL

ND4000 Manual Marine Hydraulics

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

La Marche Manufacturing Company Option 16 Series. Digital Combined Accessory Package. Installation and Operation Manual

prestige Control Application Supplement - ACVMax

EXPERT TRI-STAR. Temperature controller. User s Manual

Control Application. Supplement - ACVMax

Series DCT1000DC Dust Collector Timer Controller Specifications Installation and Operating Instructions

MULTIPERFORMER ISO ISOBUS. ELECTRONIC EQUIPMENT for LIQUID and MICROGRANUAL PRODUCT DISTRIBUTION CONTROL USER INSTRUCTION MANUAL

Fan Coil Thermostat Controller Specification and Installation Instructions. Model TFHB24F3XYZ1 with External Humidity Sensor and BACnet Communication

Application Manual Loop Water Controller

Flopurge TS. Operation Manual

User Guide. Shaft Speed 6 6-Channel Shaft Speed Monitor. Calibration and Operation Software Reference UDJ701-5

ATS UV Monitor Operations Manual

DC200 Digital Dispenser Operating Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

VAV Thermostat Controller Specification and Installation Instructions. Model TRO24T4XYZ1

Mark 25 Ultrapure Water Conductivity Analyzer

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

PF1000 CONTROLLER. for the. Heateflex Corporation 405 E. Santa Clara St. Arcadia, CA TEL: (626) ; FAX: (626)

Pioneer-R16 Gas Monitor Operator s Manual

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Dryer Moisture Systems Inc. Dryer Master M 2. Product Manual

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

RPM1600 Series Room Pressure Monitors

Guardian II Pipeline Washer B Instruction Supplement

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

ExactLogic BACnet Communicating Thermostat EXL01627 Sequence Datasheet Fan Coil with Modulating Fan and Heat or Cool Floating Heating and Cooling

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

Synergis Master Controller 2.2 Integration Guide for Assa Abloy IP Locks

Browser Manual ProMinent ProMtrac Cooling Tower Water Treatment Controller

QuadraTouch Pro Software Manual Dryer Control System

ICS Regent. Fire Detector Input Modules PD-6032 (T3419)

Rev B, 9/2/2009. Kodiak Chiller Overview

PowerWizard. Level 1.0 & Level 2.0 Control Systems Training

Beacon 800 Gas Monitor Operator s Manual

Engine Control Unit, ECU 100 Functional description Additional functions Parameter list

FlexTouch. Siemens FTS-320-6RC-4C Recycle Collection System Control 4 Color Touch Screen PLC. Document: FTS-RC IM 8 FEB 2018

Freeman 1592 Baler Operating System Manual

1 MXS Strada: connect and configure alarm LEDs

PowerCommand FT-10 Network LONWORKS System Annunciator

Instructions for the hand-held micro terminal of the fan motor control system, TBLZ-2-75 SILVER C

Installation and User Instructions

FPX103C Auto DUAL LOOP AUTO/MANUAL FIRE CONTROL PANEL Iss 1.0

DEFA HOME. User Manual Base Unit PRO

- Data Brochure Universal Reset Module 422

PIR/INT & PIR/INT-D. Batten mount PIR detectors. Product Guide. Overview. Features

Tempered Water Logic Control OPERATION l TROUBLE SHOOTING

Distributed By: M&M Control Service, Inc Building Technologies

Interactive Fire Control Panel IFS7002 one signal loop Instruction Manual

Service Settings. EASY PFA Universal Biomass Heating System Controller. Technical Documentation

B-40/B-41 Modulating Temperature Controller

D3000. Installation & Setup Guide

MVE TS Controller (Touch Screen)

TECHNICAL MANUAL CVM 20 C 5005 CV/04-99 GB

Analog Room Pressure Monitor RPC Series

ExactLogic BACnet Communicating Thermostat EXL01625 Sequence Datasheet Fan Coil with Modulatating H/C and PO-PC H/C

Dryer Controller M720

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Temperature Controller CC24-7 UNIBOX USER S MANUAL Legion Dr. Mason, MI USA October 2010 Ph. (517) Fax (517)

Integrated PIR detectors

AD-1272 Advanced Thermal Dispersion Probe Airflow Measuring System

Getting Started with Live Exceptions

Power Locking Installation Manual

Halton SAFE / 7.14 user guide and installation instructions

Sensor Control Panel

1600 Gas Controller. User s Manual. Industrial Scientific Corporation. Version 3.2 September 1, 2006

EBMPIR-MB. Batten mount PIR detectors. Product Guide. Overview. Features

918TS Manual 1/26/09-1 -

INSTALLATION INSTRUCTIONS

Ceiling PIR presence detector DALI / DSI dimming. PIR Sensor. IR Receiver. Light Level Sensor. Status LEDs. PIR Sensor.

Ceiling Microwave presence detector - DALI / DSI 12-24V AC/DC. Microwave Sensor. IR Receiver. Light Level Sensor. Status LEDs.

ExactLogic BACnet Communicating Thermostat EXL01622 Sequence Datasheet

Entero Voice Alarm system.

Transcription:

STEP 1: Pre-Programming Preparation: STEP 3: Row Status/Row Width Setup Press Row I/O button. Enter desired values using Table A as reference. Press Work Screen button to return to the Main Work screen. STEP 4A: Material Configuration Setup (Granular Monitor) 16 different materials can be configured as seeding and fertilizer controls. Material defaults on the Control Setup screen are 1-4 (Granular Control) 5-8 (Granular Monitor) Fert 1-4 (Granular Control) Fert 5-8 ( Granular Monitor). Reference the System Configuration section in the Operator s Manual for additional setup instructions. Press the Control Setup button. At the Control Setup screen, select one of the 16 material buttons to edit (labeled 1-8 and Fert 1-8). Enter desired values from Table B. Press the Control Setup button to return to the Control Setup screen. 5. Repeat steps 2-4 for additional materials. 6. Press the Channel Setup button to enter channel setup constants. The Quick Setup Guide assumes the Virtual Terminal, Working Set Master Module, Working Set Member Module, and all sensors have been connected and properly installed. Quick Setup Guide assumes channel 1 (front bin) to be seed and channel 2 (rear bin) to be fertilizer. Reference the Operator s manual for installation instructions. Power on vehicle via ignition switch to activate Virtual Terminal (VT). Main menu will display pre-programmed default settings. If errors are detected (e.g., failed sensors, incorrect configuration) an alarm and code will display. Alarms are silenced by pressing the Alarm Cancel button. Refer to Operator s manual for troubleshooting assistance. The system has three user levels. The system loads in user level 1 (operator level) at every power cycle. Access to user level 2 and 3 screens to setup constants (system configuration) requires a password available through an authorized Great Plains dealer. TABLE A: Row Status/Row Default Value/ Width Setup STEP 2: Auto Configuration (identifies sensors connected to each module) Auto config is performed at the factory, but may need to be done in the field as changes are made to the system or if options are added to the base system. Verify Auto Config results are correct. Check that the correct number of rows are assigned to the correct module and number of hoppers and pressure sensors are assigned accurately. To Run Auto Config: Press Next Page until Module Configuration button appears. Press Module Configuration button. Press AUTO CONFIG button. Hour glass will indicate system is detecting the presence of seed, pressure, or hopper sensors connected to each module and automatically assigns to the appropriate module. 5. When Auto Config completes, press the Row Assign button to display the Row Assignment screen to verify correct Row # is assigned to the correct module based on serial number. 6. Enter # of rows assigned to each module. Row Assignment for 80 Drop System Module Configuration Row Assignment/ Screen Configuration Screen SERIAL NUMBER MODULE TYPE MODULE ADDR. 10001-18R 1 10002 -POM 2 10003 WSMR-18R 3 10004 WSMT-ACCGP 4 10005-18R 5 10006-18R 6 10007-18R 7 MODULE # OF Drop ADDR. 1 TYPE -18R ROWS 16 # s 1-16 3-18R 16 17-32 5-18R 16 33-48 6-18R 16 49-64 7-18R 16 65-80 Row Assignment # s change for 32, 40, and 64 row configurations. Row Width (40 row) 20 ft/6 m Row Width (32 row) 20 ft/6 m TABLE B: Material Setup Default Value/ Matrl Label 1 Material Name can be customized to accurately define the material s type. Creating a name allows for quick identification at the Control Setup screen. Type Gran Monitor Desired type of application control channel being used for a specific material. The Material Type must correctly match the Control Type to be able to select material from the Control Setup screen and operate properly. Display Units Lbs/Ac Kg/ha Displays primary and secondary readout units in Lbs/Ac or Kg/ha. Target Rate Density # Outlets Used Per Meter Box 60 lbs 67.3 Kg 60 lbs/bu 0.77 Kg/L Calibration Constant 85831 Pul/Ft 3 Desired rate of application in lbs/ac or Kg/ha. Establishes the density of material. Density units can be entered in lbs/bu or lbs/ft 3. 4 Establishes the number of towers for that channel. 3031 Pul/L Number of pulses to drop 1 cubic foot/liter of material. Variable Cal Constant Disabled Adjusts the accuracy of the seed amount dispensed based on the seed type. A selection of 25 pre-defined seed types are available. Low Shaft RPM 10 Set to desired min seed meter RPM. High Shaft RPM 75 Set to desired max seed meter RPM. Prod Level Alarm 0 Sets the weight to trigger alarm indicating low seed levels in lbs. s per Pound/Kg 6 in 15 cm 7.5 in 19 cm 3000 Lb 6614 Kg Enter row width distance to calculate seed rate data (360). inches/cm Enter row width distance to calculate seed rate data (400). inches/cm Auto Update Width Disabled When enabled, implement width will automatically calculate. If disabled, manually enter implement width. (40 row) 80 drop (32 row) 64 drop (40 row) (32 row) 245 in 622 cm 242 in 615 cm 245 in 622 cm 242 in 615 cm 240 in 610 cm Manually enter implement width in inches/cm. Limited Flex All Row Spacings Pop/Block Pattern Every row blockage Determines which sensors are used to calculate population and those used only for blockage detection. Select pre-defined Every Row. For other pre-defined patterns, reference Operator s manual. Converts the current application rate from Lb/ac to KS/Ac to determine population and population alarms. High Pop Alarm 20% This is the percentage above the target population of the seeder channel if rows are assigned to the seeder channel. If rows are not assigned to a seeder, this is the percentage above average seeder population for all unassigned rows. Low Pop Alarm 20% This is the percentage below the target population of the seeder channel if rows are assigned to the seeder channel. If rows are not assigned to a seeder channel, this is the percentage below average seeder population for all unassigned rows. On/Off Pattern Every Row On On/Off Pattern indicates specific row patterns to be on or off. Select pre-defined seeder All Row On pattern. For other pre-defined seeder patterns or individual row settings, reference Operator s manual. Row Fail Rate 2/1 Sets the threshold for row failure alarms. Entered in seeds per second. 2/1 is a row failure threshold of 2 seeds in 1 second. 1

STEP 4B: Material Configuration Setup (Granular Monitor) 16 different materials can be configured as seeding and fertilizer controls. Material defaults on the Control Setup screen are 1-4 (Granular Control) 5-8 (Granular Monitor) Fert 1-4 (Granular Control) Fert 5-8 (Granular Monitor). Reference the System Configuration section in the Operator s manual for additional setup instructions. Enter desired values from Table B. Press the Control Setup button to return to the Control Setup screen. 5. Repeat steps 2-4 for additional materials. 6. Press the Channel Setup button to enter channel setup constants. STEP 5A: Channel Setup (Granular Monitor) Channel 1 is generally used for granular seed monitor setup. Press the Control Setup button. At the Control Setup screen, select one of the 16 material buttons to edit (labeled 1-8 and Fert 1-8). At the Channel Setup screen, verify that channel 1 is set to granular seed monitor. Enter desired values using Table C as reference. To set up additional control channels (granular fert monitor, granular fert control, granular seed control, RPM Control), press the Next Channel button. When channel setup is complete, press the Work Screen button to return to the Main Work screen. Once a control channel has been established as granular seed monitor, any new materials established as granular seed monitor on the Material Setup screen will automatically be added as optional materials for granular seed monitor channels on the Control Setup screen. STEP 5B: Channel Setup (Granular Monitor) Channel 2 is generally used for granular fertilizer monitor setup. At the Channel Setup screen, press the Next Channel button to setup additional control channels. Set channel 2 as granular fertilizer monitor. Enter desired values using Table D as reference. Continue to set up control channels 3 and 4, if 5. required. Press the Work Screen Button when channel configurations are complete to return to the Main Work screen. Once a Control Channel has been established as Granular Monitor, any new materials established as granular fertilizer monitor on the Material Setup screen will automatically be added as optional materials for granular fertilizer monitor channels on the Control Setup screen. TABLE B: Material Setup Gran Fert Mon TABLE C: Channel Setup Gran Mon Default Value/ Type Gran Mon Set desired Channel Type as Gran Monitor. Material Name 1 Displays only materials that have been configured for the channel type. Input Filter 50 Feedback frequency filter for the control channel. DO NOT CHANGE. Constant 360 Constant establishes the number of pulses for one revolution of the feedback sensor. If a DICKEY-john application rate sensor is used, the value should be set to 360.0. Gear Ratio 0 Specifies the actual ratio from the feedback sensor to the seed meter shaft RPM. Number of revolutions the feedback sensor turns in relation to one revolution the seed meter turns. # of Rows (6 in/15 cm) # of Rows (7.5 in/19.1 cm) # of Rows (6 in/15.0 cm) # of Rows (7.5 in/19.1 cm) Channel Width (40 rows) 80 drops Channel Width (32 rows) 64 drops Channel Width (40 rows) Channel Width (32 rows) Default Value/ 80 Double Shoot 64 Double Shoot 40 Single Shoot 32 Single Shoot Matrl Label Fert 1 Material Name can be customized to accurately define the material s type. Creating a name allows for quick identification at the Material Summary screen. Type Gran Fert Mon Desired type of application control channel being used for a specific material. The Material Type must correctly match the Control Type to be able to select material from the Control Setup screen and operate properly. Units Lbs/Ac Kg/ha Displays primary and secondary readout units in Lbs/ac or Kg/ha. Target Rate 50 lbs/ac 56 Kg/ha Density 60 lbs/ft 3 0.96 Kg/L Entry of a specific number of seed rows to the control channel. Row assignment is given a priority based on the channel and will be assigned sequentially thereafter. Channel 1 is always assigned to the first set of rows, Channel 2 next set of rows, and so on. 245 in/622 cm Manual entry of the channel width for rows assigned to a specific channel. Width calculation can be determined by # of seeder rows assigned to the channel multiplied by the row spacing. 242 in/615 cm 245 in/622 cm 242 in/615 cm Channel Width 240 in/610 cm All Limited Flex Drills Desired rate of application in lbs/ac or Kg/ha. Establishes the density of material in lbs/ft 3 or Kg/L. # Outlets Used Per 4 Establishes the number of towers for that channel. Meter Box Calibration Constant 82996 Pul/ft 3 2931 Pul/L Number of pulses to drop 1 cubic foot/liter of material. Variable Cal Constant Disabled Adjusts the accuracy of the seed amount dispensed based on the seed type. A selection of 25 pre-defined seed types are available. Low Shaft RPM 10 Set to desired min fert meter RPM. High Shaft RPM 75 Set to desired max fert meter RPM. Prod Level Alarm 0 Sets the weight to trigger alarm indicating low fertilizer levels in lbs. Row Fail Rate 2/1 (2 seeds every 1 second) Set to desired number of seeds per second to trigger seed sensor failure alarm. TABLE D: Channel Setup Gran Fert Mon Default Value/ Type Gran Fert Mon Set desired Channel Type as Gran Fert Monitor. Material Name Fert 1 Displays only materials that have been configured for the channel type. Input Filter 50 Feedback frequency filter for the Control Channel. DO NOT CHANGE. Constant 360 Constant establishes the number of pulses for one revolution of the feedback sensor. If a DICKEY-john application rate sensor is used, the value should be set to 360.0. Gear Ratio 0 Specifys the actual ratio from the feedback sensor to the seed meter shaft RPM. Number of revolutions the feedback sensor turns in relation to one revolution the seed meter turns. Channel Width (40 rows) 80 drops Channel Width (32 rows) 64 drops Channel Width (40 rows) Channel Width (32 rows) 245 in/622 cm Manual entry of the channel width for rows assigned to a specific channel. Width calculation can be determined by # of seed rows assigned to the channel multipled by the row spacing. 242 in/615 cm 245 in/622 cm 242 in/615 cm Channel Width 240 in/610 cm All Limited Flex Drills 2

STEP 6: Ground Speed Calibration Setup Press the Speed Set button. Enter desired values using Table E as reference. Press the Work Screen button when Ground Speed Calibration configurations are complete to return to the Main Work screen. STEP 7: Accessory Setup Hopper Setup Press the Module Configuration button. Press the Hopper Assign button. Verify # of hoppers is correct or enter # of hoppers assigned. Press the Hopper Set button. 5. Enter desired values using Table F as reference. RPM Setup 6. Press the RPM Module button. 7. Enter # of RPM sensors, if required. 8. Press the RPM Setup button. 9. Enter desired values using Table F as reference. Pressure Setup 9. At the Module Configuration screen, press the PSI Module button. 10. Verify # of pressure sensors or enter the # of pressure sensors assigned. 1 Press the Pressure button. 1 Enter desired values using Table F as reference. For additional information regarding hopper level, RPM, and pressure sensor setup, reference the Operator s manual. STEP 8: Summary Screen The Summary screen provides an overview of setup constants for active control channels. 5. At the Main Work screen, press the Next Page button. Press the Summary button To view specific control channel configurations, press the respective control channel box 1- Press inside a yellow highlighted box to open a specific screen for editing. Press the Work Screen button to return to the Main Work screen. Press to open Channel Setup Summary Screen TABLE E: Ground Speed Setup Default Value or Source Digital Frequency Select Ground if radar is connected to ISO tractor cab harness. Select Digital Frequency if radar or hall-effect is connected to WSMT actuator harness. Gspd Constant Shutoff Speed Min Override Master Switch Timeout Ground Speed Failure Alarm Delay 12,192 PUL 10,000 PUL 100 m 0.01 mph 0.02 kph 0.0 mph 0.0 kph Input based on pulse count produced by the ground speed sensor over 400 distance. See Operator s manual for calibration instructions. Indicates the minium ground speed allowed before the system shuts off all control channels. Minimum Override takes over when actual ground speed is below the designated value. The control operates at this speed until actual ground speed rises above the minimum override speed or the actual speed drops below the shutoff speed. 5 sec Determines the length of time before the system disables the operate function after ground speed is 0 if the master switch remains in the ON position. 5 sec Set to desired number of seconds alarm sounds after the ground speed is zero and seed flow continues. (monitor only) Implement Lift Enabled Implement lift switch must be in the down position to operate. TABLE F: Accessory Setup Default Value or # of Hoppers 2 # of hopper sensors connected to each module. # of hopper data items for each listed module and the Hopp # s value will automatically populate if Auto Config is used to configure installed sensors. Hopper Logic Level Hopper Alarm Delay Channel (Hopper #1) Channel (Hopper #2) Active Lo Sets the active state to low signifying that an alarm is generated if the sensor s output is in a low state. Use this setting if the connected sensor outputs a low condition when empty similar to the DICKEY-john hopper sensor. 5 sec Controls the delay time between the detection of a high/low hopper alarm condition and the generation of the resulting alarm. The value is entered in seconds. 1 Assigns hopper sensor 1 to channel 2 Assigns hopper sensor 2 to channel # of RPMs 1 Number of RPM sensors connected to each module to monitor a shaft/fan. High Alarm 4600 RPM Sets the RPM value at which a high RPM warning error is generated. Low Alarm 2000 RPM Sets the RPM value at which a low RPM warning error is generated. High Alarm Delay 5 sec Establishes the delay between the detection of a high RPM alarm condition and the resulting alarm display (entered in seconds). Low Alarm Delay 5 sec Establishes the delay between the detection of a low RPM alarm condition and the resulting alarm display (entered in seconds). RPM Constant 3 pul Number of pulses per sensor revolution. RPM Filter 50% Filters the signal out of the RPM sensor. Disable Control on Low Alarm # of Pressure s Disabled High Alarm 20 oz/in 2 8.6 Kpa Low Alarm 3 oz/in 2 3 Kpa Allows for disabling of all control channels if the RPM value of the selected sensor falls below the low alarm level setting. 2 Number of pressure sensors connected to each module to monitor pressure. Sets the pressure value at which a high pressure warning error is generated (oz/in 2 /Kpa). Sets the pressure value at which a low pressure warning error is generated (oz/in 2 /Kpa). High Alarm Delay 5 sec Establishes the delay between the detection of a high pressure alarm condition and the resulting alarm display (entered in seconds). Low Alarm Delay 5 sec Establishes the delay between the detection of a low pressure alarm condition and the resulting alarm display (entered in seconds). Pressure Filter 50 Filters the signal out of the pressure sensor. 3

Battery + - Tractor Harness Tractor Cab Harness 467980455 Chassis Ground Implement Breakaway Harness 467980131 connects to hitch harness Harness 467980452 (5 Terminal) or Harness 467980451A (10 Terminal) Virtual Terminal Connect Cab Harness to Implement Can Harness 5 Extension 467980142 RS232 GPS (467980451 Harness) Tractor ECU Controller (467985060S1) Master Switch (467980124S1) Ignition Connect to switched +12VDC. NOTE: This wire must be connected to switched +12VDC Radar Speed 467833000S1 Mounting Kit 467830760 (Radar connected to either tractor harness or WSMT as shown below) 467983502 Output Module 467982000S1 467980485 810-342C Option 32 Row Single Shoot Module Harness Dj SE style 46775320S1 (dust plug on 9-12 rows) (dust plug on 9-12 rows) WSMT2 Module ACCGP 5 Extension 467980142 (dust plug on 9-12 rows) (dust plug on 9-12 rows) 3 Rear Hitch Harness 467980360 Implement Breakaway Harness 467980131 connects to hitch harness WSMT II Aircart Main Harness 467980856B Zeromax Front (left) 833-456C A - Red B - Yellow 464360033S1 Zeromax Rear (right) 833-456C A - Red B - Yellow Fan RPM Fan Solenoid Hopper Level Front (left) 466820721S1 464360033S1 467980475 467980474 Green 466970014S1 Implement Lift Switch 464820520S1 Pressure Front (left) 466820922S1 Application Rate Front Left 464361530 Application Rate Rear Right 464360178S1 463500122 Radar Ground Speed 467833000S1 Mounting Kit 467830760 Pressure Rear (right) 466820922S1 Hopper Level Rear (right) 466820721S1 467980494 Clutch 833-523C System Component Installation Locate and install system components as shown in the diagram. Note how the modules are identifi ed and which modules are located on which sections in this system. Connect module harnesses together with included extensions. Modules connect to the WSMT harness connection. Plug all unused connectors with included dust plugs. Secure any excess wires with tie wraps. See Operator s Manual for additional installation information. Power on monitor and program with correct constants as described on this Quick Start Guide. Note: The pre-programmed constants in the monitor may cause an error code on the initial power on of a new system. This is normal and can be cleared by pressing and ESC holding key for 2 seconds. 5. 4

Module Harness Dj SE style 46775320S1 (dust plug on 11-12 rows) Option 40 Row Single Shoot (dust plug on 11-12 rows) (dust plug on 11-12 rows) (dust plug on 11-12 rows)

Module Harness Dj SE style Rows 1-8 Rows 1-8 64 Row Double Shoot Rows 9-16 Rows 9-16 Rows 17-24 Rows 17-24 Rows 25-32 Rows 25-32

Module Harness Dj SE style Rows 1-10 Rows 1-10 457901815 80 Row Double Shoot 3 Extension 459680920 Rows 11-20 Rows 11-20 Rows 21-30 Rows 21-30 15 Extension 459680922 Rows 31-40 Rows 31-40

823-317C IntelliAg 6 Row Tramline Kit 467983507 Output 467982000S1 Operator s Manual 467983507 11001-1543 Output 467982000S1 823-319C IntelliAg 2 Row Tramline Kit 467983507 Operator s Manual 11001-1543 Output 467982000S1