installation manual DM3862 RM2554 DM2663 RM2551 Refrigerator for LP-gas & electric operation DM2852 ! AVERTISSEMENT ! WARNING FOR YOUR SAFETY

Similar documents
INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLATION AND OPERATING INSTRUCTIONS

Installation Requirements for Models:

Installation Manual. For Australian refrigerator models: N304M.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

user manual DM3862 DM2663 Refrigerator for LP-gas & electric operation DM2852 AVERTISSEMENT ! WARNING FOR YOUR SAFETY FOR YOUR SAFETY

Model: Dometic RM2453

User s Manual for FT SERIES THE

RV REFRIGERATOR LP-GAS & ELECTRIC

APEX CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

Vulcan Fire Module WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

REFRIGERATOR MODEL RM7732 MODEL RM7732 AND ELECTRIC OPERATION

200i User s information manual

RM2612 RM2812 REFRIGERATOR MODEL INSTALLATION & OPERATING INSTRUCTIONS REFRIGERATOR FOR LP/GAS AND ELECTRIC OPERATION

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

GAS COOKTOP INSTALLATION INSTRUCTIONS

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

Alpine CONDENSING HIGH EFFICIENCY GAS-FIRED HOT WATER BOILER

INSTALLATION AND OPERATION MANUAL GAS SKILLETS MODELS: GTS-30 GTS-40

An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. WARNING

Multi-Function Cooktop

OWNER S MANUAL INSTALLATION OPERATION MAINTENANCE CONVECTION OVEN MODEL # RDCO-32

Air Conditioner

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

Mascot LX. User s Information for. Wall-Mounted, Modulating Boiler Model MLXH 50, 75, 100, 125, 150, 175, & 220 MBH

Installation Instructions T 9822 Gas Dryer. en - US, CA. To prevent accidents

WARNING WARNING WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

CBO-750 HYBRID-R OVEN Instructions Manual

OPERATING INSTRUCTIONS

USER'S INFORMATION MANUAL ES2 GAS - FIRED

MTI INSTALLATION, OPERATION AND MAINTAINANCE MANUAL

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

RM7030 Product No REFRIGERATOR MODEL INSTALLATION & OPERATING INSTRUCTIONS MODEL RM7030

THC-175DF INDUSTRIAL / COMMERCIAL SPACE HEATER. Certified to / Certifié à CGA 2.14 M2011 Conforms to / Conforme à ANSI std Z83.

SAFE DRINKING WATER AND TOXIC ENFORCEMENT ACT

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

- Do not store or use gasoline or other

AES III RM2355 RM2455 RM Contact a qualified person. RM4605 RM4805 FOR YOUR SAFETY FOR YOUR SAFETY

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

51 Aikins Street Winnipeg, Manitoba Canada, R2W 4E3

Installation instructions for the T 9820 Gas Dryer

Installation Instructions

southbend A MIDDLEBY COMPANY INSTALLATION AND OPERATION MANUAL CG214 (E) CG314 (E) CG414 (E) CG220 (E) CG320 (E) CG325 (E) GAS BOILERS MODELS:

Owner s Manual. For Australian refrigerator models: N304.3 (93 liter 3-way operation with LP gas, 240 volts AC, or 12 volts DC )

WARNING Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance. WARNING

Automatic Dryers. Installation. Keep These Instructions for Future Reference. (If this machine changes ownership, this manual must accompany machine.

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

GPC PASTA PRO INSTALLATION & USER OPERATION MANUAL

REFRIGERATOR FOR LP-GAS AND ELECTRIC OPERATION RA1302. quality leisure line products Corporate Office 2320 Industrial Parkway Elkhart, IN 46515

INSTALLATION OPERATING, AND SERVICE INSTRUCTIONS FOR SUBURBAN DIRECT VENT SEALED COMBUSTION GAS HEATER MODEL GT-10D

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

THC 85 / 175 INDUSTRIAL / COMMERCIAL SPACE HEATER

Installation Instructions

WARNING. For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM

Using it in an enclosed space can kill you.

Owner s Information Manual

Owner s Guide Installation & Operation

USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN

Fig. 1 - Unit PGD4, PGS4, WPG4

Installation Instructions

INSTALLATION & OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

Installation Instructions Dual Fuel Ranges

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN

DESIGN CLASS FUNCTION

Bosch 80% AFUE Gas Furnace BGS80 Model

Installation Instructions

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

INSTALLATION GUIDE Dual Fuel Ranges

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

Service Manual Model 3163

Installation Instructions

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

THC 85N / 175N INDUSTRIAL / COMMERCIAL SPACE HEATER

Viking Installation Guide

Installation Instructions

Installation and Owner s Manual For model 322X - a 1.7 cu. ft., 2-way refrigerator. For model 323X - a 1.7 cu. ft., 3-way refrigerator.

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

Gas Cooktop Installation, User and Service Instructions GMS 955.1

Installation Instructions

Service Procedures for the Model SL31-31 Dryer

Dometic. AMERICANA Model RM2652 & RM2852 REFRIGERATOR MODEL RM2652 RM2852 INSTALLATION & OPERATING INSTRUCTIONS

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

An LP-cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. WARNING

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

iq251, Gen II Operation & Installation Manual WARNING AVERTISSEMENT

Installation Instructions

Transcription:

RM25 RM254 RM245 RM2454 RM255 RM2554 DM2652 DM2662 DM266 DM2852 DM2862 DM862 NDM062 NDR292 installation manual Refrigerator for LP-gas & electric operation FOR YOUR SAFETY If you smell gas:. Open windows. 2. Don t touch electrical switches.. Extinguish any open flame. 4. Immediately call your gas supplier. Pour votre sécurité Si vous sentez une odeur de gaz:. Ouvrez les fenêtres. 2. Ne touchez à aucun interrupteur.. Éteignez toute flamme nue. 4. Avertissez immédiatement votre fournisseur de gaz. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Pour votre sécurité Ne pas entreposer ni utiliser de l essence ni d autres vapeurs ou liquides inflammables à proximité de cet appareil ou de tout autre appareil.! WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.! AVERTISSEMENT Une installation, un réglage, une modification, une réparation ou un entretien non conforme aux normes peut entraîner des blessures ou des dommages matériels. Lisez attentivement le mode d emploi fourni avec l appareil. Pour obtenir de l aide ou des renseignements supplémentaires, consultez un installateur ou un service d entretien qualifié ou le fournisseur de gaz. USA Corporate Office CANADA Service Office 220 Industrial Parkway Elkhart, IN 4655 Dometic Corporation Dometic Corporation 48 Zatonski, Unit 220 Industrial Pkwy. Brantford, ON NT 5L8 Elkhart, IN 4656 For Service Center Assistance CANADA Phone: 574-294-25 Call: 800-544-488 Phone: 59-720-9578 82525806 (French 82525850) 2006-2007 Dometic Corporation LaGrange, IN 4676 MO-M 0724

introduction This manual describes the installation procedure of RM25, RM254, RM245, RM2454, RM255, RM2554, DM2652, DM2662, DM266, DM2852, DM2862, DM862, NDM062 and NDR292. The installation is to be performed by qualified personnel only and must conform to all relevant local authorities. Please read this manual thoroughly before installing the refrigerator. To ensure safe and efficient operation, the refrigerator must be installed as described in this manual. Be aware of possible safety hazards when seeing alert symbols on the refrigerator as well as in this manual. For information about maintenance and operating instructions, refer to the User manual. contents Certification and Code Requirements 4 Ventilation requirements 4 General information.................................. 4 Ventilation heights................................... 5 Clearances........................................ 5 Overall and recess dimensions......................... 6 installation instructions 7 Installing the refrigerator............................. 7 Securing the refrigerator.............................. 7 Connections....................................... 9 mounting instructions Reversing the door swing............................. Mounting the door panel(s)............................ refrigerator removal 2 appendix A - rearview equipment appendix B - wiring diagrams 6 Symbols The following symbols are used throughout the manual:!! WARNING CAUTION Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation, which, if not avoided, may result in minor or moderate injury. CAUTION Used without the safety alert symbol indicates, a potentially hazardous situation which, if not avoided may result in property damage. Information step-by-step instructions - -

Certification and Code Requirements This appliance is certified under the latest edition of ANSI Z2.9 CSA.4 Refrigerators using gas fuel. The installation must conform with local codes, or in absence of local codes, the following standards as applicable. In the U.S. the installation must conform with: In CANADA, the installation must conform with: National Fuel Gas Code, ANSI Z22./NFPA 54 Natural Gas and Propane Installation Code, CSA B49. (latest edition). CSA Z240 RV Series, Recreational Vehicles. Recreational Vehicles Code, ANSI A9.2 (latest edition). Current CSA Z240.4, Gas-equipped Recreational Vehicles Manufactured Home Construction and Safety Standard, Title and Mobile Housing. 24 CFR, Part 280. If an external electrical source is utilized, the refrigerator, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the National Electrical Code, ANSI/NFPA 70 - (latest edition). If an external electrical source is utilized, the refrigerator, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, the Canadian Electrical Code, CSA C22., Parts I and II - (latest edition). Ventilation requirements General information Ventilation is one of the requirements for proper cooling unit operation. The installation should be made in such a manner as to separate the combustion system from the living space of the mobile home or recreational vehicle. Openings for air supply or for venting of combustion products should have a minimum dimension of not less than /4 inch. Proper installation requires one lower fresh air intake and one upper exhaust vent. Certified installations require one roof vent and one lower side vent. The ventilation kits shown in this manual have been certified for use with the different models as displayed in the Certified Vent System Kits table. The ventilation kits must be installed and used without modification! An opening toward the outside at floor level in the refrigerator compartment has to be provided for ventilation of heavier-than-air fuel gases. The lower vent of the recommended kits is provided with proper size openings. The flow of combustion and ventilating air must not be obstructed. CAUTION It is of especially importance that the airflow around the burner housing, the boiler insulation and the flow of combustion gases must not be obstructed. Items placed in the vicinity of the refrigerator compartment accordingly must be secured away from the refrigerator tubing and flue. The lower side vent is fitted with a panel, which provides an adequate access opening for ready serviceability of the burner and control manifold of the refrigerator. This should be centered on the back of the refrigerator. Model RM25 RM254 RM245 RM2454 RM255 RM2554 DM2652 DM2662 DM266 DM2852 DM2862 DM862 NDM062 Kit No. 2A A A 4A Certified Vent System Kits Components Roof Base Roof Cover Lower Side Vent Lower Side Vent Upper Side Vent Lower Side Vent Power Vent Ass y Upper Side Vent Upper Side Vent Lower Side Vent Lower Side Vent Roof Base Roof Cover Lower Side Vent Roof Base Roof Cover Lower Side Vent ndr292 5A Roof Base Roof Cover Lower Side Vent Power Vent Ass y Part no. 06.XXX* or 089.XXX* 064.XXX* or 0894.XXX* 0950.XXX* RM8 RM2A RM8 08705.75** RM2A 09492.00 RM8 09492.00 06.XXX* or 089.XXX* 064.XXX* or 0894.XXX* 0950.XXX* 06.XXX* or 089.XXX* 064.XXX* or 0894.XXX* 0950.XXX* 06.XXX* or 089.XXX* 064.XXX* or 0894.XXX* 0649.XXX* 08705.744** * Replace XXX with the color code numbers. For color codes, contact your supplier. ** Alternate instructions forwarded with the Ventilator Kit. For further information, contact your dealer or distributor. - 4 -

Ventilation requirements Ventilation heights It is essential that all maximum or minimum dimensions are strictly maintained, as the performance of the refrigerator is dependent on adequate flow of air over the rear of the refrigerator. Minimum ventilation heights Roof vent and lower side vent A Upper and lower side vent B A Minimum ventilation height The upper vent should be centered over the condenser coil at the back of the refrigerator. inches mm inches mm Condenser RM25 RM254 787 4 864 RM245 RM2454 RM255 RM2554 7-/4 960 44-/2 0 B DM2652 DM2662 DM266 DM2852 DM2862 DM862 NDM062 57-/4 465 6-/4 620 Minimum ventilation height Condenser ndr292 65 65 Clearances Minimum clearances (in inches) to combustible materials: Top (G) 0 Side (K) 0 Bottom (L) 0 Rear (M ) 0 / (RM25 & RM254) M: The distance between the rearmost part of the refrigerator and the wall behind it. General view. Features may vary according to model. - 5 -

Ventilation requirements Overall and recess dimensions Dimensions Overall Recess Model RM25 RM254 RM245 RM2454 RM255 RM2554 DM2652 DM2662 DM266 DM2852 DM2862 DM862 NDM062 NDR292 Height A Width B Depth C Height H Width W Depth D inches 0-5/2 2-7/8 22-22/2 29-/4 20-/2 2-/8 mm 766 556 577 756 52 542 inches 7-/8 24-7/8 24-/6 9-9/6 2-/6 24 mm 948 62 627 928 602 60 inches 4-/2 24-7/8 24-/6 42-5/8 2-/6 24 mm 04 62 627 08 602 60 inches 54-2/2 24-7/8 26-/2 5-/4 2-/6 24 mm 88 62 66 65 602 60 inches 60-5/64 24-7/8 26-/2 59-5/6 2-/6 24 mm 544 62 66 522 602 60 inches 60-54/64 24-7/8 26-5/8 59-5/6 2-/6 24* mm 544 62 676 522 602 60* inches 59-/2 -/6 26-2/2 59-/6 2-/4 24* mm 52 855 677 500 82 60* * Add " (25 mm) depth for units with one or two optional ventilator fans. Side view View from above General view. Features may vary according to model. - 6 -

Installing the refrigerator installation instructions Be careful when installing the refrigerator models NDM062 & NDR292. These are equipped with the latest vacuum insulated panel technology. The insulating panels are located on the top, back, bottom, sides and doors. If the surface is punctured, loss of insulation will occur, resulting in poor refrigerator performance. For a proper installation, follow these instructions: Make sure the floor is solid and level. The refrigerator must be level and installed in a substantial enclosure. Do not install the appliance directly on carpeting. Carpeting must be removed or protected by a metal or wood panel beneath the appliance, which extends at least full width and depth of the appliance. RM245, RM2454, RM255, RM2554, DM2652, DM2662, DM266, DM2852, DM2862, DM862, NDM062 & NDR292 A wood strip must be in place across the upper opening of the enclosure. The top frame of the refrigerator will be anchored to the wood strip with screws. When installing the refrigerator in the enclosure, all areas within the recess have to be sealed. Verify that there is a complete seal between the front frame of the refrigerator and the top, sides and bottom of the enclosure. A length of sealing strip is applied to the rear surface of the front frame for this purpose. The sealing strip should provide a complete isolation of the appliance s combustion system from the vehicle interior. RM25 and RM254: Apply a sealing strip to the foremost floor of the enclosure. Be careful not to damage the sealing strip when the refrigerator is put in place! Securing the refrigerator It is important to follow the sequence in securing refrigerator in enclosure since failure in doing so can cause leakage between the frame and cabinet. Any space between the counter, storage area or ceiling and top of the refrigerator greater than /2 inches should be blocked. The heat produced at the rear of the refrigerator will become trapped in this space, making the top of the refrigerator hot and reduce the efficiency of the refrigerator. After the refrigerator is put in place (ensuring a combustion seal at the front frame), the refrigerator is to be secured in the enclosure with screws (not included). RM25 & RM254 Install the five screws in the following order:. 2. Four screws installed through the front frame. (To cover the screw heads, use the plugs in the parts bag.) One screw installed in the rear base. 2 RM245, RM2454, RM255, RM2554, DM2652, DM2662, DM266, DM2852, DM2862, DM862, NDM062 & NDR292 RM25& RM254 General view. Features may vary according to model. - 7 -

installation instructions RM245, RM2454, RM255, RM2554, DM2652, DM2662, DM266, DM2852, DM2862, DM862 & NDM062 Install the screws in the following order:. Two screws installed through the front base. (Installation of the lower front strip.) The refrigerator is provided with a lower front strip (shipped as a loose part). Attach the front strip after the refrigerator is set into the cutout opening. a) b) Install the lower front strip by sliding it under the bottom hinge plate. The hinge plate can be on the right or left side depending on the door swing. Once the lower front strip is slipped under the hinge, the part is possible to swing into place. Secure the refrigerator and the lower front strip with two screws: One screw through the hinge and on the opposite side and then, one screw through the lower front strip.. One screw installed in the rear base. NDR292 Install the screws in the following order:. Two screws installed through the front base. (Installation of the lower front strip.) The refrigerator is provided with a lower front strip (shipped as a loose part). Attach the front strip after the refrigerator is set into the cutout opening. a) b) Install the lower front strip by sliding it under the bottom hinge plate. Secure the refrigerator and the lower front strip with two screws: One screw through each hinge. 2. Two screws installed in the top frame. a) Open the door. Gently push the tabs out of the hole in the hinge with a flat blade screwdriver 2 (both sides). b) Carefully tilt the top decoration panel and lift to remove from top frame. Be careful not to damage the circuit board and wires. c) Install the two screws in the top frame, the holes are accessible from underneath. d) Seal the opening for the screws with aluminum tape. e) Replace the top decoration panel. Be careful not to pinch the wires behind the panel. Make sure the tabs snap back into the holes in the hinge plate. 2.. Screws installed in the top frame. a) Open the doors and remove the four screws that secure the top decoration panel to the top frame. Two screws are accessible from underneath and two are located on each side of the lock retainer securing the decoration panel to the front frame. Save screws for reinstallation of the top decoration panel. b) See step 2, b-e in the previous instruction. Two screws installed in the rear base. - 8 -

installation instructions Drain water hose Drill a hole through flooring. Seal around the hose that goes through the drilled hole and ensure that it does not kink when run through the floor. Check to make sure that the supplied hose is long enough in order for the water to drain outside of the vehicle. If not, the installer will have to supply the extra length of hose. RM25 & RM254 NDR292 Hole for drain water hose RM245, RM2454, RM255, RM2554, DM2652, DM2662, DM266, DM2852, DM2862, DM862 & NDM062 Hole for drain water hose Connections Gas connection Hook up to the gas supply line is accomplished at the manual gas valve, which is furnished with a /8 SAE (UNF 5/8-8) male flare connection. All completed connections should be examined for leaks using a solution of liquid detergent and water.! WARNING Hole for drain water hose Drill the hole in the cut out opening of the base plate EXPLOSION HAZARD. Never use an open flame to check for gas leaks. Failure to heed this warning could cause an explosion resulting in death or severe personal injury. The gas supply system must incorporate a pressure regulator to maintain a supply pressure of not more than inches water column. When testing the gas supply system at test pressures: > /2 psi - the refrigerator and its individual shutoff valve must be disconnected from the gas supply piping system. /2 psi - the appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve. If detailed instructions on the installation and connection to the gas supply are required, please contact your dealer or distributor. Testing LP gas safety shut off The gas safety shut off must be tested after the refrigerator is connected to LP gas supply. RM254, RM2454, RM2554, DM2662, DM266, DM2862, DM862, NDM062 & NDR292 To test the gas safety shut off, follow these steps:. 2.. 4. 5. 6. 7. 8. 9. 0.. Start the refrigerator. Switch to GAS mode. Check that the gas flame is lit and the GAS mode indicator lamp is on. Close the manual gas shutoff valve at the back of the refrigerator. Wait for approx. 6 minutes. The CHECK indicator lamp should be lit and the GAS mode indicator lamp should be off. Remove the protection cover. Open the manual gas shutoff valve. Do not change any button positions on the control panel. Apply a non corrosive commercial bubble solution to the burner jet orifice. No bubbles should appear at the opening of the burner jet orifice. The presence of bubbles indicates a defective gas safety shutoff, and service is required. If no bubbles are present at the burner jet orifice, rinse it with fresh water. Be careful not to damage the burner jet orifice. Put back the cover. Press the ON/OFF button off and then back on. Normal operation of the burner should return. Allow the burner to operate for a minimum of five minutes. RM25, RM245, RM255, DM2652 & DM2852 To test the gas safety shut off, follow these steps:. 2.. Start the refrigerator without connecting to 20V AC. Check that the gas flame is lit. In AUTO mode, the AUTO mode indicator lamp is on. Follow steps - in the previous instruction. - 9 -

installation instructions Electrical connection 20 V AC connection The refrigerator is equipped with a grounded three-prong plug for protection against shock hazards. It should be plugged directly into a properly grounded three-prong receptacle. Do not cut or remove the grounding prong from this plug! The free length of the cord is 2 feet. It should be routed to avoid direct contact with the burner cover, flue cover or any other components that could damage the cord insulation. To allow easy access through the vent door, it is recommended that the receptacle is placed like this: RM25 & RM254 To the left of the refrigerator and 4-6 above the refrigerator mounting floor RM245, RM2454, RM255, RM2554, DM2652 & DM2852 To the left of the refrigerator and 6 above the refrigerator mounting floor DM2662, DM266, DM2862, DM862 & NDM062 To the left of the refrigerator and above the refrigerator mounting floor. NDR292 To the right of the refrigerator and 0 above the refrigerator mounting floor. 2V DC connection RM245, RM255, DM2652 & DM2852: These refrigerator models are not designed for 2V DC operation of the cooling system. However, 2V DC must be supplied to operate the controls. RM254, RM2454, RM2554, DM2662, DM266, DM2862, DM862 & NDM062: These refrigerator models require a continuous 2V DC supply to maintain the automatic energy system. The connection is made to the positive (+) and negative (-) terminals of the terminal block on back of the refrigerator, see Appendix A - Rearview equipment. Correct polarity must be observed when connecting to the DC supply. Do not use the chassis or vehicle frame as one of the conductors. Connect two wires at the refrigerator and route to the DC supply. Ensure the connections are clean, tight and free from corrosion. Ensure that the wires from the battery to the refrigerator are able to handle the load. The distance the current must travel from the battery to the refrigerator dictates the AWG wire size to be used. Inadequate wire sizes can result in a voltage drop which affects the refrigerator performance. For -way models, the voltage drop affects the wattage output of the 2V cartridge heater and the refrigerator performance. The 2V DC heater is fused with a 0 amp. in-line blade fuse. Recommended wire sizes are displayed in the following table: RM245, RM2454, RM255, RM2554, DM2652, DM2662, DM266, DM2852, DM2862, DM862 & NDM062 20V AC receptacle olt AC ptacle 4-6 6 NDR292 20V AC Volt AC receptacle 0 0 MODEL maximum total Conductor wire length WIRE Size Length RM25 RM245 RM255 DM2652 DM2662 DM2852 DM2862 DM862 NDM062 NDR292 AWG ft m 4 2 7 27 5 8 RM254 RM2454 RM2554 DM266 0 8 7 27 5 8-0 -

mounting instructions Reversing the door swing For all models, except NDR292, the refrigerators are equipped with hinges that makes it possible to change the direction the door opens by moving the hinges to the opposite side. A special hinge kit must be used in order to change the door swing. For conversion kit number, refer to the User manual, Appendix A - Spare parts. For additional information, please contact service point or distributor service dept. for assistance. Mounting the door panel(s) Optional door insert panels are available for all models except NDR292. The refrigerator is normally delivered without door panel(s). Before starting the mounting work, read this instruction thoroughly and check that the panel dimensions are in compliance with those given in the following table: Panel dimensions max. thickness 5/2" (4 mm) With screws To mount the panel, follow these steps:. 2.. 4. 5. Open the door 90 degrees. On new refrigerators, the decoration strip is taped inside the door; if installed on the door, remove the door decoration strip (2) by removing its three screws (). NDR292: Fresh food compartment door - remove three screws. Freezer compartment door - remove two screws. Insert the vertical edges into the grooves of the door frame (). Push the panel downwards so that the lower horizontal edge of the panel (4) is fitted into the bottom grove (5). Put the decoration strip across the door so that the gap is covered. Secure the decoration strip with the screws removed in step 2. Height max min Width max min UPPER mm 40 40 527 524 inch 5-27/2 5-25/2 20-/4 20-5/8 LOWER /SINGLE DOOR 2 RM25 RM254 mm 667 665 498 496 RM245 RM2454 DM2652 DM2662 DM266 inch 26-7/64 26-/6 9-5/8 9-7/2 mm 827 825 527 524 inch 2-9/6 2-/2 20-/4 20-5/8 RM255 RM2554 DM2852 DM2862 NDM062 mm 98 98 527 524 inch 8-/6 8-5/8 20-/4 20-5/8 4 Frozen food compartment 5 NDR292 mm 402 400 288 265 inch 55-/6 55-/8 0-9/6 0-7/6 Fresh food compartment NDR292 mm 402 400 40 427 inch 55-/6 55-/8 6-5/6 6-/6 - -

mounting instructions Snap in To mount the panel, follow these steps:. 2.. 4. 5. Open the door 90 degrees. On new refrigerators, the decoration strip are taped inside the door; if installed on the door, remove the door decoration strip (2) by gently pushing the four tabs away with a flat blade screwdriver (). Insert the vertical edges into the grooves of the door frame (). Push the panel downwards so that the lower horizontal edge of the panel (4) is fitted into the bottom grove (5). Snap in the decoration strip (2). 2 2 4 5 refrigerator removal Before removing the refrigerator: Verify that the AC and DC voltage leads are disconnected. Shut off the gas supply. Disconnect the gas supply line at the rear of the refrigerator. Always use a back up wrench when loosening and tightening connections. To remove the refrigerator, follow these steps:. Cap the gas supply line. 2. Loosen the screws anchoring the refrigerator to the enclosure.. Slide the refrigerator out of the compartment. Replacement is the reverse of removal. When reinstalling the refrigerator, make sure the sealing strips are properly positioned. Check all connections for gas leaks. - 2 -

appendix A - rearview equipment RM25 Heater Power module cover Flue baffle Drain water hose Protection cover Screw for protection cover Flexible cord 2 V DC Terminal block Inlet fitting Burner jet Manual gas shutoff valve RM254 Heaters Relay Power module cover Flue baffle Drain water hose Protection cover Screw for protection cover Flexible cord 2 V DC Terminal block Inlet fitting Burner jet Manual gas shutoff valve - -

appendix A - rearview equipment RM245, RM2454, RM255 & RM2554 Relay, -way only Heater Flue baffle Power module cover Protection cover 2V DC 2 volt Terminal block Screw for protection cover Burner jet Manual gas shutoff valve Inlet fitting Flexible cord Drain water hose DM2652, DM2662, DM266, DM2852, DM2862, DM862 & NDM062 Heater(s) Relay, -Way only Thermofuse Flue baffle Power module cover Protection cover 2V DC Flexible cord 2 volt DC Terminal block Drain water hose Inlet fitting Burner jet Manual gas shutoff valve Screw for protection cover - 4 -

appendix A - rearview equipment NDR292 Heaters Power module cover Thermofuse Flue baffle 2V DC Protection cover Burner jet Manual gas shutoff valve 2 volt Terminal block Flexible cord Drain water hose Inlet fitting - 5 -

appendix B - wiring diagrams RM25, RM245 & RM255 RM254, RM2454 & RM2554-6 -

appendix B - wiring diagrams DM2652, DM2662, DM2852 & DM2862 DM266-7 -

appendix B - wiring diagrams DM862 & NDM062 (SS)* NDM062 (B)* * SS = Stainless steel doors B = Door insert panels - 8 -

appendix B - wiring diagrams NDR292 (SS)* 8 5 0 J + 2 V L A C G N D C L C D T G R E E N P O R A N G E P 4 B L U E P 2 R E D P 5 B R O W N P 6 B L A C K P A P 4 P P 2 P 4 8 9 E M L 8 9 9 P 2 P 2 2 B J 2 J 4 C J 5 J 6 J 7 J 8 J 0 P F A N F A N + 2 V L J 4 A J 6 G R O U N D N V J 5 J 2 5 A J 7 J 8 H J 0 P P P 2 2 4 2 4 5 6 2 H F 8 G U 9 L N 5 K 2 V D C S R 6 N T A U F E D I S P L A Y B O A R D + 2 V L A C G N D C L C M G J L P F A N F A N A C E G J L N B D F H K M P C I R C U I T B O A R D P O W E R F U S E A F U S E 5 A C I R C U I T B O A R D D I S P L A Y E L E C T R O D E L A M P S W I T C H L A M P H E A T E R 2 0 V A C H E A T I N G C A B L E T E R M I N A L B L O C K T H E R M I S T O R S O L E N O I D V A L V E R E T A I N E R T H E R M O F U S E R T V 5 7 9 S U 2 4 6 8 P R O T E C T I V E E A R T H C H A S S I S G R O U N D T E S T P O I N T T H E R M O F U S E F U S E A B L A C K B R O W N R E D Y E L L O W G R E E N G R E E N / Y E L L O W B L U E G R E Y W H I T E NDR292(B)* 8 5 2 6 D T S G R E E N P O R A N G E P 4 B L U E P 2 R E D P 5 B R O W N P 6 B L A C K P A P 4 P P 2 P 4 9 8 E K 9 9 P 2 P 2 2 F A N F A N G B J 2 J 4 C J 5 J 6 J 7 J 8 J 0 J + 2 V L L J 4 J 5 J 2 P A 5 A J 6 J 8 J 0 2 4 2 4 5 6 2 T J 7 G R O U N D N H F 8 O N P L + M 2 V D C D I S P L A Y K A C I R C U I T B O A R D P O W E R S S O L E N O I D V A L V E B O A R D B F U S E A T T E S T P O I N T C F U S E 5 A U R E T A I N E R E D C I R C U I T B O A R D D I S P L A Y W C H A S S I S G R O U N D J E E L E C T R O D E X PROTECTIVE EARTH A F S W I T C H Y F U S E A G H E A T I N G C A B L E O H H E A T E R 2 0 V A C B L A C K J T H E R M O F U S E 2 B R O W N F A N N K T H E R M I S T O R R E D L T H E R M O F U S E 4 Y E L L O W M T E R M I N A L B L O C K 5 G R E E N G F A N N S W I T C H L. A. C 6 G R E E N / Y E L L O W O L A M P 7 B L U E P S W I T C H L A M P 8 G R E Y S 9 W H I T E W 9 5 L N 2 0 V A C Y X 6 U H * SS = Stainless steel doors B = Door insert panels - 9 -

TO THE INSTALLER PLEASE AFFIX THESE INSTRUCTIONS TO THE REFRIGERATOR TO THE CONSUMER PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE