SUNOCO Heat Transfer Fluids

Similar documents
DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

Strategies in Optimizing Condensate Return

IN THE PULP AND PAPER INDUSTRY

Cast Line Heaters The Benefits of This Space Saving Electric Heater

Maintain. a TOWER of POWER. Part One How to. Don t let out of site, out of mind prevent you from keeping cooling towers running efficiently

New levels of reliability for hydraulic systems

In-Line Air Separators

Here is your conveying solution: Product group D.

Coal Handling and Processing. Advanced Solutions for Coal-Related Environmental Dust Control. Better Air is Our Business

Theory of Operation: How Parts Cleaning Works

LIST Price - $2, Model Number: MFD-1-27-GX-X-B-14. *Quick Delivery of Units are Subject to Prior Sales

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

Installation and servicing instructions

Oil burners fuel unit with solenoid valve

How about Savings in Time, Money, Energy and Longer Life?

Oil burners fuel unit with solenoid valve

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

IRRIGATION EQUIPMENT LTD. The Perfect Solution for Water Filtration and Irrigation Problems

VAC-U-DRY VACUUM DEHYDRATION SKIDS

What is a Secondary Pressure Drainer?

Desiccant Breathers: A Front Line Defense in the War on Contamination

Section 2. Product overview & label familiarisation

GRAVITY SCREEN FILTER

VAC-U-DRY VACUUM DEHYDRATOR

Technical Specification

Technical Specification l Tank Pumps Hi-flow 1L & 2L Part No: 1L FP2096 / 2L FP2122

ACORE Filtration Co.,Ltd provides engineering,

WHITE PAPER The Importance of Rinsing in Metal Finishing Operations

P3X Series Membrane dryers

Aluminum Dust Management in a Metallizing Facility

CalMag Heating Pack Installation Instructions

SB Series Brazed Plate Heat Exchanger Installation Manual

TRI-PLATE B INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS PART NO EFFECTIVE MARCH 1, 1983 REPRINT APRIL 16, 1999

COOLING. 4/05/04 Std.

Removal of Non-condensable Gases and Air Is Critical In A Steam System

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

HF345 S9 Operators Manual

Extrusion Blow Molding Resin or Color Change: Performance Tips

Reactor-Boiler and Auxiliaries - Course 433 BOILER STEAM AND WATER SYSTEMS

V A C U U M A N D P R E S S U R E T E C H N O L O G Y

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

B r i g h t I d e a s

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

Portable Purification zf04 Systems Models PVS 185, 600, 1200, 1800, 2700

Wet ElectroStatic Precipitator

Form 2143 Date: 4/3/03 Repl: 2/1/99 BRYAN STEAM LLC. Installation and Operating Service Manual BOILER FEED SYSTEM

Extrusion Profile Resin or Color Change: Performance Tips

Introduction to Control Technology

ProMoss TM Plant-Based Water Treatment Solves Problems in Tobacco Manufacturing Plant Air Washer Systems

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Safe Use of a Class II Biological Safety Cabinet

Minima User Guide and Installation Manual

Understanding of Surface Heat Tracing of Bulk Storage Tanks for Viscous and High Pour Point Fluids - By, H. R. Mullan

NILEATOR ATOR. Dyna-Fog ANILE. Cold Fog ULV Aerosol Applicator. Instruction Manual For Operation, Service and Maintenance

CalMag Filter Installation Instructions

Phoenix C4XE - Membrane Based Portable Lube and Hydraulic Oil Purifier Cart For use in Hazardous Duty Locations.

Eliminator TotalGuard Installation Manual

Watch Water USA Green Chemical Technology

Microdiesel Cleaning & Assembly Products

Dirt and Air Separators

WHITE PAPER ASEPTIC PROCESSING WHILE MAINTAINING PRODUCT INTEGRITY. Published by Marlen International, Inc.

5CONSIDERATIONS WHEN SELECTING A DESICCANT BREATHER FOR YOUR EQUIPMENT

ACC is suitable for all types of diesel engines. The ACC / fresh water mixture has no flash point and cylinder lubrication is not impaired.

Independent Study Shows Sludge Build-up Significantly Affects Hydronic Heating System Performance

!!! Sample Written Program For Your Company. For BOILER SAFETY. Provided By:!!!

CARPET MAINTENANCE GUIDE

Flanged Immersion Heaters

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

Why does gas build up in the oil line?

Aspects of the. Following these key guidelines during a compressor changeout can ensure a successful, more efficient replacement.

Clean, Dry Air System

Fact Sheet. Recovery of Steam Condensate Utilizing Membrane Technology at Carlisle SynTec Inc., Greenville, Illinois

ZERO AIR GENERATOR MODEL 7000 INSTRUCTION MANUAL

Cooling System Equipment

WLP & WCP Series Water Treatment Systems 2015

Desiccants & Driers. By Norm Christopherson

AIR SENTRY DESICCANT BREATHERS

Installation Manual. Instrucciones de instalación y manual de usuario 1

HVAC 101: Residential Typical system components & cleaning techniques

Jacopa Tipping Bucket

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Tel: Fax: Website:

HOW TO SELECT AN INDIRECT THERMAL TECHNOLOGY FOR INDUSTRIAL MATERIALS PROCESSING

First Revision No. 1-NFPA [ Chapter 2 ]

HEAT EXCHANGE IN GENERAL

Go Greener, with Gas.

CPF PRODUCT DESCRIPTION

VUD. Vac-U-Dry Vacuum Dehydrators. hyprofiltration.com/vud

Tubular Industrial Process

Please take time to carefully read through these guidelines before using your Kamco pump.

NOZZLE MIX COMBINATION BURNER NMC200 SERIES

CLEANING FOR EXTENDED TOOL LIFE & IMPROVED TABLET QUALITY. natoli.com

MARCH 12-14,1991 DEARBORN INN HOTEL DEARBORN (DETROIT), MICHIGAN

Scale Stopper Plus Installation & Start-Up Guide

Installation and Operation Instructions. Versa. Screw Plug Oil & Water Immersion Heater. PD January 2018

Monticello Pump Services, Inc

So far, we have covered the basic concepts of heat transfer and properties.

Mixers and Flocculators. For Municipal Water Treatment

Installation, Operation and Maintenance LOK-FLANGE Multitube Heat Exchangers

Transcription:

SUNOCO Heat Transfer Fluids Our SUNOCO HEAT TRANSFER OIL provides an excellent heat transfer media for manufacturing processes where temperatures will not exceed 600 F*. These premium oils are highly refined paraffinic oils to provide excellent oxidation stability and low temperature properties. Applications SUNOCO HEAT TRANSFER OILS are designed for use in closed system boilers and other transfer systems equipped with expansion tanks where temperatures do not exceed 600 F. Features & Benefits SUNOCO HEAT TRANSFER OILS employ highly refined base stocks for efficient heat conduction and excellent thermal and oxidation stability. Non-corrosive to equipment. Designed to minimize coking and varnish build up Product and Typical Properties Product Code 12813 1613 12443 1603 1653 Product HTO-22 HTO-32 HTO-21 HTO-46 HTO-68 Viscosity, cst @ 40 o C 22.0 32.0 41.0 46.0 68.0 Viscosity, cst @ 100 o C 3.8 4.65 6.2 6.2 8.6 Viscosity Index 100 104 106 105 95 Flash Point, o C 190 215 225 221 230 Pour Point, o C -17-15 -13-15 -12 Color 1.0 1.0 0.5 1.0 1.0 Conradson Carbon, % Nil Nil Nil Nil Nil API Gravity, o API 32 32 32.5 32 30.1 * Do not exceed 600 o F (316 o C) in your system, as this will cause rapid degradation of your HTO and ultimately result in the need to recharge the HTO almost immediately

SUNOCO Heat Transfer Fluids SUNOCO HTO Charging Procedure Heat transfer systems will accumulate varnish, carbon, sludge and other process contaminants over time. If your system needs to be cleaned and/or you are planning to change the type of HTO you are using in your system, consider using SUNOCO HTO-C Cleaning Fluid or SUNOCO HTO-F Flushing Fluid before charging fresh HTO into your system. If you simply need to recharge SUNOCO HTO into your system, the following procedure can be used. 1. Operate the system at 230 o F (110 o C) to 255 o F (124 o C) or just below the flash point of the HTO. This will ensure that particulates are adequately suspended in the HTO so they can be removed when the fluid is drained. 2. Turn off the heater and continue to run the circulating pump to keep the particles suspended as you allow the system temperature to cool to an acceptable temperature to allow the HTO to be safely drained from the system. 3. Stop the circulating pump and drain the HTO quickly from all low points. 4. Recharge the system with SUNOCO HTO from all the low point drains in the system to prevent the formation of air pockets. Open the high point vents in the system to purge the air from the system and close them once the air is removed. 5. Start the circulating pump without heat to help remove any air pockets (you will hear

SUNOCO Heat Transfer Maintenance Fluids Maintaining the cleanliness of your heat transfer equipment is essential for efficient operation. Periodically the heat transfer system should be cleaned to remove varnish, carbon, sludge and other process contaminants that accumulate over time. Cleaning the system is also recommended before charging the system with a new type of heat transfer fluid. SUNOCO offers two products designed to maintain the operation of your heat transfer equipment. SUNOCO HTO-C is our cleaning fluid designed for systems that contain a heavy buildup of deposit, flow rates are reduced, and in cases where the replacement heat transfer oil is a different type than what is currently being used. SUNOCO HTO-F is our flushing fluid designed for systems that do not contain a high level of deposits and contaminants and where the replacement heat transfer oil is compatible with the existing fluid. The use of a flushing fluid is best when the system is easy to completely drain. SUNOCO HTO-F is designed to work in conjunction with our HTO-C cleaner to achieve optimum results in heavily coked systems. SUNOCO HTO-C Cleaning Fluid Procedure 1. If the HTO can be filtered, then filter the existing fluid to 40 micron or less to remove particulates. This will ensure that the larger particulates do not remain in the system when the HTO is drained. 2. Depending on how severely degraded the fluid has become; add 4% to 20% of SUNOCO HTO-C to the existing HTO. If necessary remove some of the existing HTO to allow the cleaning fluid to be added to the suction side of the system. A secondary pump may be required to accomplish this. Do not add the HTO-C to the expansion tank. 3. Circulate the cleaning fluid for a maximum of 48 hours at 230 o F (110 o C) or at the system operating temperature. Do not exceed 600 o F (316 o C). 4. Toward the end of the cleaning period, reduce heater outlet temperature to 220 o F (106 o C) to facilitate the removal of any remaining HTO as well as any particulates collected with the cleaning fluid.

SUNOCO HTO-C Cleaning Fluid Procedure (continued) 5. Turn off the heater and continue to run the circulating pump to keep the particles suspended as you allow the system to cool to a temperature that allows the HTO-C to be safely drained from the system. 6. Stop the circulating pump and drain the HTO quickly from all low points. 7. If the system is severely degraded, you can recharge the system with SUNOCO HTO-F and follow Steps 5 thru 10 from the SUNOCO HTO-F Flushing Fluid Procedure. If not proceed to Step 8 below. 8. Recharge the system with your SUNOCO HTO product from all the low point drains in the system to prevent the formation of air pockets. Open the high point vents in the system to purge the air from the system and close them once the air is removed. 9. Start the circulating pump without heat to help remove any air pockets (you will hear SUNOCO HTO-F Flushing Fluid Procedure 1. If the heat transfer oil (HTO) can be filtered, then filter the existing fluid to 40 micron or less to remove particulates from the HTO. This will ensure that the larger particulates do not remain in the system when the HTO is drained. 2. Operate the system at 230 o F (110 o C) to 255 o F (124 o C) or just below the flash point of the HTO. This will ensure that the remaining particulates are adequately suspended in the HTO so they can be removed when the fluid is drained. 3. Turn off the heater and continue to run the circulating pump to keep the particles suspended as you allow the system temperature to cool to an acceptable temperature to allow the HTO to be safely drained from the system. 4. Stop the circulating pump and drain the HTO quickly from all low points. 5. Recharge the system to normal capacity with SUNOCO HTO-F from all the low point drains in the system to prevent the formation of air pockets. Open the high point vents in the system to purge the air from the system and close them once the air is removed.

SUNOCO HTO-F Flushing Fluid Procedure (continued) 6. Start the circulating pump without heat to help remove any air pockets (you will hear 7. Circulate flushing fluid for a maximum of 72 hours above 200 o F (94 o C) or at the system operating temperature. We recommend a target temperature of 400 o F (205 o C). Do not exceed 600 o F (316 o C). 8. Toward the end of the flushing period, reduce heater outlet temperature to 220 o F (106 o C) to facilitate the removal of any remaining HTO and particulates collected with the flushing fluid. 9. Turn off the heater and continue to run the circulating pump to keep the particles suspended as you allow the system to cool to a temperature that allows the HTO-F to be safely drained from the system. 10. Stop the circulating pump and drain the HTO-F quickly from all low points 11. Recharge the system with your SUNOCO HTO product from all the low point drains in the system to prevent the formation of air pockets. Open the high point vents in the system to purge the air from the system and close them once the air is removed. 12. Start the circulating pump without heat to help remove any air pockets (you will hear