GESTRA Information A 1.5

Similar documents
ø D ø g ø k Max. service [barg] pressure [psig] H 1 96 L BK 45 with butt-weld ends End connections Screwed Socket-weld

opening trap 30 mm Space required for Space required for opening trap 30 mm MK 45-1 with flanged ends (to DIN)

BK 45 BK 45-U BK 45-LT BK 46

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

Steam Traps and Steam Trap Testing

Why steam trap survey?

GESTRA Information A 1.7

GESTRA. Product Overview. The optimum components for every application

GESTRA. Product Overview. The optimum components for every application

GESTRA Steam Systems BK 15. Installation Instructions Steam Trap BK 15, DN 40-50

GESTRA Steam Systems BK 37 BK 28 BK 29. Installation Instructions Steam Trap BK 37, BK 28, BK 29 BK 37 ASME, BK 28 ASME, BK 29 ASME

GESTRA. Steam Traps and Steam Trap Testing. For all applications

GESTRA. Steam traps and monitoring equipment. The right choice in every case

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

Product overview. the optimum components for every application

MK 45-1 MK 45-2 MK 45 A-1 MK 45 A-2

Installation and Testing of Inverted Bucket Steam Traps Manual

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

Float & Thermostatic Steam Traps for efficient condensate drainage of industrial process and HVAC equipment

Steam Traps. . Chambered valves such as; bleeding & venting valves and steam traps. Float Valves using a free fl oat

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

Liquid Drainers LIQUID DRAINERS

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

GESTRA Steam Systems DK 45. English. Installation Instructions Steam Trap DK 45

Steam trap checking WHY WE NEED TO CHECK STEAM TRAPS METHODS OF CHECKING TRAPS ADVANTAGES AND DISADVANTAGES PRACTICAL DEMONSTRATION

SMK 22 SMK SMK SMK 22-82

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

Chapter 2.3: Steam System

Steam Traps and Steam Specialties

Steam Trap Inspection Methods And Steam Cost Analysis

PRESSURE MOTIVE PUMP (PMP) APPLICATIONS

GESTRA Valves for Pure and Sterile Steam Systems. Intelligent solutions for sensitive processes

LQE(E,G,S) Air heater for hot water

MK 45 A. Stainless Steel Design. Installation Instructions Steam Trap MK 45 A

WHY THE REMOVAL OF NONCONDENSABLE GASES AND AIR IS CRITICAL IN A STEAM SYSTEM

Inverted Bucket Steam Traps

GESTRA Information A 1.4

PIP PNE00004 Steam Trap Guidelines

STEAM TRAPS

BK 46. Installation Instructions Steam Trap BK 46

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

Product. Add Efficiency To Your Steam Investment... Steam Traps Drain Traps Air Vents & Eliminators Accessories Piping Assemblies Replacement Kits

MAXIFLO EJECTOR SYSTEM AN INNOVATIVE APPROACH TO STEAM CONSERVATION LEVEL 4 BEE ACCREDITED

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

YARWAY NON-REPAIRABLE DRIP AND TRACER STEAM TRAPS SERIES PB, 29, 129Y AND 29S

C. B. Trading Corporation

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Steam Trap Presentation for IDEA Distribution Workshop. Presenter: Joe Radle

LONGONI ENGINEERING SRL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Ball Float Controlled. Thermo Dynamic(TD) Trap Safety Valve Condensate Pump Flash Vessel Moisture Separators Deaerator Head Steam Injector Sight Glass

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

UFGS (May 2010) UNIFIED FACILITIES GUIDE SPECIFICATIONS

POWERFLOW Series. Unvented Electric Storage Water Heaters. Installation & Operating Instructions Manual

VIFB Coil Technical Guide

Operating and installation instructions

Economical and simplified solutions that offer quality and optimum steam trap service.

205 Control Installation and Maintenance Instructions

Pump & Trap Combinations

UNIFIED FACILITIES GUIDE SPECIFICATIONS

MODELS N150/300/675/900/1500/2500/2600 INSTALLATION, SERVICING AND MAINTENANCE INSTRUCTIONS

Our Know-How. Your Peace of Mind. Steam Solutions

Inverted bucket steam traps Type OKZ PN6/PN16

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

Hoffman Specialty General Catalog

THE THERMOSTATIC STEAM TRAP

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

UNIVERSAL STYLE STEAM TRAPS WU450 Series

Powerflow Unvented water heater

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

CWS AIR-CONDITIONERS

GESTRA Steam Systems ER 50-1, ER Installation Instructions Level electrode

The right trap for the right application.

Removal of Non-condensable Gases and Air Is Critical In A Steam System

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

GESTRA. Program for Universal Connections. The Smart Solutions

Series 1140 and 1141 Temperature Regulators

Steam and Condensate Technology. Solutions which are brilliant in their simplicity. combined with a first-class design & consultancy service.

ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER OPERATIONS AND MAINTENANCE MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Steam trapping overview STEAM & CONDENSATE MANAGEMENT SOLUTIONS

MFP14 Automatic pumps for condensate and other industrial fluids

INSTALLATION, OPERATION

Polar Air Dryer. Instructions Manual PDRCF PDRCF R E F R I G E R A T E D T Y P E C O M P R E S S E D A I R D R Y E R S

The. Steam ONE-PIPE STEAM SYSTEMS

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Using the Remote Control Unit

SECTION STEAM AND STEAM CONDENSATE SPECIALTIES

OPERATIONS AND MAINTENANCE MANUAL FOR THE 8-TON TURF CART ENVIRONMENTAL CONTROL UNIT (ECU) PART NUMBER

Steam Site Guide. Steam Site Guide. Heat Exchange Applications - SI Units

InterSeptor Centrifugal Separators Operating & Maintenance Manual

How to Trap: Installation and Testing

(PD[ $LU 'U\HU 5 ( ) 5, * ( 5 $ 7 ( ' 7 < 3 ( & ( 6 6 ( ' $, 5 ' 5 < ( 5 6 ('5&) ದ ('5&) Instructions Manual

MFP14 Automatic pumps. for condensate and other industrial fluids

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

Series 151 and AV5. A wide range of process thermostatic steam traps is available to match almost any application need.

Installation, Operation, and Maintenance Information

Industrial Processing Solutions

Transcription:

Issue Date: 9/06 GESTRA Steam Systems GESTRA Information A 1.5 How to avoid operating trouble in steam and condensate systems caused by freezing of equipment and plant The recent cold winter brought us many unpleasant surprises, but, in many cases, also made us realize that those parts of a plant which are liable to freezing should be better protected. These examples and hints taken from our practical experience may help you in winterizing your plant effectively. We have to differentiate between freezing and damage caused by frost. Freezing : All parts and equipment of a plant will freeze where on shut-down water (condensate) cannot drain off completely or where the temperature during operation drops rapidly because of very low condensate flowrates (= amount of heat). Although freezing causes operating trouble or even breakdown, the plant will operate again after having thawed. Fig. 1 Duo steam trap Damage caused by freezing, however, means ruin of equipment caused by the increase in volume of water when freezing. In condensate systems the danger of freezing is greatest for the steam trap. The most frequently used types of steam traps are: 1. Duo (bimetallic) steam traps (with thermostatic/thermodynamic control) 2. Membrane steam traps (with thermostatic control) 3. Thermodynamic steam traps with valve disc 4. Float traps, either with ball float or inverted bucket. The first three types of traps mentioned do not need a water seal to operate. They can be installed in any position. Fig. 3 Thermodynamic steam trap with valve disc With freeze-proof installation in vertical lines with downward flow these traps are self-draining when the plant is shut down. Therefore they cannot freeze. This applies, too, to traps with integral non-return valve. With non-freeze-proof installation, for example, in horizontal lines or in a water pocket, pipelines and traps freeze of course, if the system is not drained. There is, however, little danger of the traps being ruined by frost as the trap body is made of rather thick-walled forged steel. The regulators are surrounded by water and so robust that they are not ruined either. What may happen is just an elongation of the cover bolts. The trap types shown in figs. 1 3, and 6 are drained to the level of the outlet port. The remaining condensate in the trap freezes, but the trap is not ruined. lf the plant is restarted the first condensate can flow off freely and after a short while the ice will have thawed. Float traps are directly controlled by the condensate level in the trap. Consequently they can only be installed in a given position. They are not self-draining and freeze if the plant is shut down. Depending on the type of material, the wall thickness of the trap body, the design features, and the direction of flow they may even be ruined by the frost. The ball floats freeze in the ice formed by the condensate and may be deformed. There is an exception, the GESTRA float trap type UNA 23/26 with Duplex control in vertical design (Fig. 6). After cooling down the ball float is lifted by the Duplex control (thermic element) so that the outlet port is opened. The condensate can flow off exactly as it would from a thermostatic trap. As the ball float hangs above the remaining water level it cannot freeze. Entleerung Fig. 2 Membrane steam trap Fig. 4 The trap must be drained, otherwise it will freeze. The ball float may freeze and be deformed. Danger of damage caused by frost.

lf the bodies of the traps shown in figs. 9, 10, 11 are in welded construction of thin metal sheet there is a further danger in the case of frost. During periods of standstill the pipelines, too, cool down and shrink. Depending on the pipe layout and supports tensile stress results which may lead to a deformation of the trap body and to cracks in the welding seams. The following examples show reasons for freezing during operation and on shutdown and possible ways of avoiding it. Danger of freezing during operation regardless of trap type Condensate systems and heat exchangers may freeze for the following reasons: 1. Faulty trap operation or completely dirt-logged strainer upstream or inside trap. 2. The differential pressure is not large enough to obtain sufficient condensate discharge. 3. Unfavourable flow conditions in the heating system of the heat exchanger (this applies in particular to air heaters using outside air). 4. Unsuitable pipe layout downstream of trap. Drain plug Fig. 6 Float trap type UNA 23/26v, self-draining. The ball float cannot freeze and be deformed. No danger of damage caused by frost. Fig. 9 The trap cannot be drained and will freeze. Danger of damage caused by frost. Vent hole Fig. 7 The trap must be drained, otherwise it will freeze. After removing drain plug, the trap can drain completely. Fig. 10 The trap cannot be drained unless the line upstream of the trap has been drained. A complete drainage is not possible. The bucket will freeze. When the plant is restarted the condensate flow through the small vent hole is not sufficient to thaw the ice in the trap. Vent hole Drain plug Fig. 5 The trap must be drained, otherwise it will freeze. The ball float may freeze and be deformed. Danger of damage caused by frost. Fig. 8 Drain plug The trap must be drained, otherwise it will freeze. Danger of damage caused by frost. Complete drainage is not possible, the inverted bucket freezes in the frozen condensate. When the plant is restarted the condensate flow through the small vent hole is not sufficient to thaw the ice in the trap. Fig. 11 The trap cannot be drained, on the contrary it remains almost completely filled with water. It will freeze and be ruined by the frost (e.g. cracks in welding seams, deformation of trap body by strain on material beyond yield point). Insulating the trap will only delay freezing and damage caused by frost.

Fig. 12 Steam trap and pipeline will freeze as the strainer in the trap is completely dirt-clogged or the trap closed because of a failure or maladjustment (possible with thermostatic traps). Avoid complete dirt-clogging of strainer and disturbances in the trap. Fig. 13 Steam trap and pipeline will freeze because the differential pressure available for the trap is not large enough to provide sufficient condensate discharge (e.g. at partial load). Increase differential pressure or maintain minimum differential pressure. p too small minimum p required Steam baffle plate Outside air Outside air Fig. 14 Heat exchanger (in particular air heaters with admission of air from outside) will freeze as a result of unfavourable flow conditions. Provide better steam distribution and thereby improved flow conditions. Fig. 15 Discharge line and possibly trap will freeze up as ice building up from the pipe outlet, the pipeline downstream of the trap being too long. This is often the case if the condensate flowrate is very low, as, for instance, in tracing systems. Install trap at the end of pipeline or keep pipe downstream of trap as short as possible. If a long pipeline cannot be avoided, insulate line.

Fig. 16 lf heating lines mounted in parallel are drained by a common steam trap, the line with the higher pressure drop may freeze. Provide individual drainage for each line. Fig. 17 Condensate line and trap will freeze because the remaining condensate cannot flow off. Drain system manually on shutdown. Fig. 18 Pipeline will freeze. Drain line manually or automatically with a GESTRA steam trap type UBK 46. The trap opens as soon as the temperature drops below approx. 80 C. The pipeline should preferably be installed so that the condensate is free to flow towards the trap. UBK 46 Danger of freezing on shut-down of a plant All traps will freeze and may be ruined by frost if they are wrongly installed, i.e. if they are not self-draining. Pipelines will freeze if they are laid such that water pockets are formed or if the condensate has to be lifted. Heat exchangers will freeze if the remaining condensate cannot flow off. Additional valves are therefore required for draining the individual parts of a plant after shut-down. These may be in the form of stop valves which have to be opened by hand, but also of GESTRA drain valves type AK 45 or GESTRA steam traps type UBK 46 which open automatically. GESTRA DISCO non-return valves may be used as automatic vacuum breakers. The following examples of installation refer only to systems equipped with steam traps which, if correctly installed are self-draining. The other trap types would need manual drainage either by opening drain plugs, if provided, or by using special valves.

Fig. 19 Pipelines upstream and downstream of trap will freeze. The condensate above the trap freezes if the trap functions also as non-return valve so that the condensate cannot flow back. Use trap without non-return valve effect. Drain pipeline manually or automatically with a GESTRA drain valve type AK 45. The AK opens automatically as soon as the pressure in the system drops below 2 bar (29 psi) the opening pressure can be adjusted. The pipeline should preferably be installed so that the condensate is free to flow towards the valve. AK 25 AK 45 Fig. 20 Pipeline is sagging (water pockets) and will freeze. Remove water pocket. Lay pipeline so that condensate is free to flow towards the trap. Fig. 21 Pipeline upstream of valves will freeze because reversal of flow inside valve prevents the condensate from flowing off completely. Use slide valves, install valve into vertical lines or install valve so that its spindle is horizontal. lf possible lay pipeline so that the condensate is free to flow towards the valves. Fig. 22 The lowest heating coil will freeze. Line upstream of trap may freeze. Mount a GESTRA condensate dampening pot type ED for the prevention of waterhammer between coil and trap and drain it either manually or automatically with a GESTRA stream trap type UBK 46 or a drain valve type AK 45. If the amount of condensate formed is low the ED is not necessary. In this case the line should be drained at its lowest point. Install thermostatic and thermodynamic traps with their covers pointing sideways. ED ED UBK 46 or AK 45

Danger of freezing: RK Fig. 23 Pipeline and possibly part of the heat exchanger will freeze as condensation of the remaining steam produces a vacuum so that the condensate cannot flow off. Prevent the formation of vacuum by installing a GESTRA DISCO non-return valve as vacuum breaker. Fig. 24 The heating coil will freeze at all low points. Very unfavourable pipe layout. Empty pipelines by blowing compressed air through them. Only traps should be used with sufficient air-venting capacity.

GESTRA AG P. O. Box 10 54 60, D 28054 Bremen Münchener Str. 77, D 28215 Bremen Telephone +49 (0) 421 35 03 0, Fax +49 (0) 421 35 03 393 E Mail gestra.ag@flowserve.com, Internet www.gestra.de 810672-01/906cm 1979 GESTRA AG Bremen Printed in Germany