Series B Inverted Bucket Steam Traps

Similar documents
INSTRUCTION MANUAL HS-208REVI

INSTRUCTION MANUAL HS-229G

Armstrong J Series Float, Thermostatic Steam Traps, Condensate Controllers & Liquid Drainers Installation and Maintenance Manual

Series 1140 and 1141 Temperature Regulators

Series 47 and 247 Mechanical Water Feeders. Series 47-2 and Combination Mechanical Water Feeder/Low Water Cut-Off ! WARNING

Elite Primer Baldor Series External Pond Pump

ICS Float and Thermostatic Steam Trap Installation and Operation Manual

AIC Series Float & Thermostatic Steam Trap Installation and Maintenance Instructions

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

CHAMPION PUMP OWNER S MANUAL

Technical Data TYPE T14 & T14D TEMPERATURE PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4511A T14 PILOT

Installation and Testing of Inverted Bucket Steam Traps Manual

! WARNING. Replacement Head Mechanism INSTRUCTION MANUAL MM-413F

Inverted Bucket Steam Traps

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-315(C)

Installation and Maintenance "L" and "LS" Series

ECONO FLO 2.7HP VARIABLE SPEED PUMP OWNER S MANUAL

SMF PUMP OWNER S MANUAL

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS. Table of Contents WARNING.

ECONO FLO VSA 165 VARIABLE SPEED PUMP OWNER S MANUAL

INSTALLATION, OPERATION

SELF-PRIMING CENTRIFUGAL PUMPS BMLS-M & BMLS-H

SERVICE GUIDE Armstrong Inverted Bucket Steam Traps

LC Series - Light Commercial Pump Station Installation and Operation Manual

Niles Steel Tank Hot Water Generator Installation and Operation Manual

Inverted Bucket Steam Traps. for efficient condensate drainage of industrial and HVAC equipment

PT15 MATERIAL : DIMENSIONS - Nominal in inches. AVAILABLE SPARES: Disc (Packet of 5) ORDERING INFORMATION: Refer to "HOW TO ORDER" page.

TABLE OF CONTENTS STEAM TRAPS INVERTED BUCKET SERIES PAGE FLOAT AND THERMOSTATIC SERIES PAGE THERMOSTATIC THERMODISC B0 26. How to Select All 107

Steam System Best Practices Document No. 11

INSTALLATION, OPERATION

STEAM TRAPS FOREST PRODUCTS LIBRARY FOREST RESEARCH LABORATORY OREGON STATE UNIVERSITY. Information Reviewed and Reaffirmed. August No.

Bulletin 301-N SERVICE GUIDE. Armstrong Inverted Bucket Steam Traps

SuperKlean Washdown Products

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

QUIETFLO OWNER S MANUAL

Why steam trap survey?

OWNERS GUIDE TO INSTALLATION AND OPERATION

INSTRUCTIONS FOR USE PORTABLE VACUUM SYSTEM LEI Part # s / , , , IMPORTANT INFORMATION

Model: 1413 Model: 1418 Float-Controlled Condensate Trap, PN 100

Steam Trap BK 45 BK 45-U BK 45-LT BK 46

S and SF Inverted Bucket Steam Traps Installation and Maintenance Instructions

Ace Heating Solutions, LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

Hoffman Specialty General Catalog

! WARNING. Before using product, read and understand instructions.

FOOD WASTE DISPOSER INSTALLATION AND USE MANUAL

INFINITY FLUIDS CORPORATION

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD

INSTALLATION, OPERATION

Ace Heaters LLC INSTALLATION and MAINTENANCE INSTRUCTIONS for ACE STORAGE TANKS INSTALLATION AND HOOKUP

INSTALLATION, OPERATION & MAINTENANCE MANUAL FOR DRY PAK PACKAGED COMPRESSED AIR TREATMENT SYSTEM MODEL: DPP-150 WARNING

Operating Manual. Model: 1400 Model: 1400-N RIFOmat Float-Controlled Condensate Traps, PN Safety instructions. 2 General description and use

INSTRUCTION MANUAL. Keep this manual in a safe place for future reference TEMPERATURE CONTROL STEAM TRAP LEX3N-TZ LEX3N-TZ.

! WARNING. Before using product, read and understand instructions.

Installation Instructions Part No , Part No Part No

Installation Instructions

Daikin Water Cooling, Heating, and High Capacity Booster Coils

mechanical. OPERATION Rapidrop Global

Installation, Operation and Maintenance Guide. Steam Coil Installation, Operation and Maintenance. steam coils

TESTING STEAM TRAPS TO KEEP YOUR SYSTEM OPERATING EFFECTIVELY AND EFFICIENTLY

! WARNING. Before using product, read and understand instructions.

Model AV Alarm Valve With and Without Model RC-1 Retard Chamber European Conformity Valve Trim General Description

SERVICE MANUAL. For Service & Parts please call APK THERMAL at or SAFETY INSTRUCTION

INSTALLATION, OPERATION AND MAINTENANCE MANUAL IFB HEATING COILS

Installation, Operation & Maintenance Instructions

FT600 & FT601* Steam Traps Float & Thermostatic Steam Trap. Float & Thermostatic STEAM TRAPS

HALLMARK INDUSTRIES INC. HALLMARK INDUSTRIES INC. Safety WARNING WARNING. Must reset the voltage! Shallow Well Jet Pumps

! WARNING. Before using product, read and understand instructions.

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

STOP. SAFETY INFORMATION Please read and understand this entire manual before attempting to assemble, operate or install the product.

Chapter 2.3: Steam System

OPERATOR'S MANUAL CD 400 / CD 500

13-1. Temperature Regulator

CHLORIDE GASES CHLORIDES

SuperFlo High Performance Pump

User s Information Manual

Installation & Operating Guide

DESCRIPTION AND INSTALLATION

Model Series Series

VENTS. Main Steam Vents. How to Select Steam Vents. For Steam Vent selection information, please refer to Selection Guidelines on page 133.

User s Information Manual

HKF 8180 Operating instructions

Installation and Maintenance Manual Forbes Marshall Bucket Trap FMBT50

VERTICAL TUBE HEATING COILS MV & VIFB MODELS

INSTALLATION AND OPERATION MANUAL STEAM COIL BASE CONVECTION STEAMER MODEL SCX-16

WATER HAMMER something that never should occur in a steam system

USER'S INFORMATION MANUAL

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

F-T, FT-P, F-L AND F-P SERIES

YARWAY PROCESS THERMODYNAMIC STEAM TRAPS SERIES 40/40D AND C250/260

Operating Manual. Model: Float-Controlled Condensate Trap, PN Safety instructions. 2 General description and usage

INSTALLATION OPERATION MAINTENANCE LANCASTER MODELS X99M33 & X99M50

F-P, F-L, FT-P AND FT-L SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

Installation Instructions

MODEL SS1B PLUS PACKAGED STEAM GENERATOR SG-101. Installation, Operation & Maintenance Instructions. Instruction No.

KPS-DS, KLS-DS, KPT-DS AND KLT-DS SERIES 2/3 JACKETED DIRECT STEAM TILTING & STATIONARY KETTLES PARTS AND SERVICE MANUAL

WAL-RICH CORPORATION SINCE 1950

OPERATING AND MAINTENANCE MANUAL FOR VERTICAL IMMERSION HEATED STEAM BOILERS. Technical Control Systems Limited MODELS "VIHS"

Detailed Cleaning Instructions

WARNING. Before using this product read and understand instructions.

Transcription:

Installation & Maintenance Instructions H-208(E) eries Inverted ucket team Traps eries 0 eries 1 eries 2 eries 3 eries 4 eries 6

WARNING CAUTION! WARNING efore using product, read and understand instructions. ave these instructions for future reference. All work must be performed by qualified personnel trained in the proper application, installation, and maintenance of steam systems in accordance with all applicable codes and ordinances. To prevent serious burns, wear heat resistant gloves when opening and closing steam valves, or handling hot equipment. To prevent serious personal injury from steam pipe blow down, connect a temporary pipe between the steampipe opening and a drain, or stand at least 100 ft. (30m) from the pipe opening. To prevent property damage, personal injury, or death, cap off the gate valves if they are not connected to a drain and when they are not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury or death. IMPORTANT: To prevent system damage from water hammer or sudden shock, open supply valves slowly. If you are uncertain about the product s adaptability for your application, please call the factory or authorized representative before using the product. The trap seat rating (stamped on the nameplate) must be equal to or greater than the maximum pressure differential across the trap. 2

OPERATION UCKET TRAP EAT I OPEN TO VENT AIR OR DRAIN CONDENATE During start-up, air is vented through the bleed hole, at the top of the bucket, into the return line. leed Hole Cover Open eat Condensate entering the trap will flow around the bucket and drain through the open seat. Inlet Outlet ody ucket UCKET TRAP EAT I CLOED TO RETAIN LIVE TEAM As steam flows into the bucket trap it collects at the top of the bucket. The buoyancy of the steam raises the bucket and closes the seat. The bucket remains full of steam until more condensate enters the trap. The cycle is then repeated. Inlet leed Hole Cover Closed eat Outlet ucket ody team ubbles Through Water UCKET TRAP WITH OPTIONAL THERMAL VENT FOR FATER AIR VENTING Models with an optional factory installed thermal vent in the bucket allow faster air venting during start-up. Inlet Outlet Thermal Vent 3

INTALLATION eries 0, 1, 2, 3 & 4 Inverted ucket Traps 1. Determine where to install the trap, based on the following requirements: a. The trap must be located as close as possible and below the equipment to be drained. b. The trap must be in a straight run of horizontal pipe and pitched to allow condensate to flow into the trap inlet and away from the trap outlet. Refer to the Typical Piping Diagrams at the right. c. Plenty of space around the trap is needed for servicing, which may include removal of the body or cover. tatic Head Tee Fitting tatic Head Tee Fitting TYPICAL PIPING DIAGRAM Trap Draining to Open Drain Equipment Drain Point Inlet Pipe hut-off Valve Dirt Pocket Y trainer Pipe Union Gate Valve For low Down To Drain ucket Trap Outlet Pipe Pipe Elbow Trap Draining to Gravity Return Line Equipment Drain Point Inlet Pipe hut-off Valve Dirt Pocket Y trainer Pipe Union Gate Valve For low Down To Drain hut-off Valve Tee Fitting ucket Trap hut-off Valve To Return Line Gate Valve For Test & Pressure Relief Pipe Elbow Gravity Return To Vented Receiver Trap Draining to Overhead Return Line or Pressurized Return Line tatic Head Equipment Drain Point Inlet Pipe hut-off Valve Pipe Union ucket Trap Tee Fitting Check Valve hut-off Valve Return Line tatic Head Against Discharge 1 /2 psi/ft. (.035 bar per.3m) Tee Fitting Dirt Pocket Y trainer Gate Valve For low Down To Drain Gate Valve For Test & Pressure Relief Pressurized Return Line 4

2. Install near trap piping: a. Install a shut-off valve (A) on the inlet pipe (). b. Install a Hoffman pecialty Y trainer (C) on the inlet pipe (). A c. Install a gate valve for blow down (D) by connecting it to the Y trainer drain tapping (C). C D d. Cap off the outlet pipe (X). e. lowly turn steam on with full pressure for (5) five minutes to blow down the inlet pipe (). f. Turn off steam and allow pipe to cool. g. Remove cap from the outlet pipe (X).! WARNING To prevent serious personal injury from steam pipe blow down, connect a temporary pipe between the steam pipe opening and a drain, or stand at least 100 ft. (30m) from the pipe opening. Failure to follow this warning could cause property damage, personal injury, or death. D X Pipe Opening! CAUTION To prevent serious burns, the internal pressure of the trap must be 0 psi (0 bar) before servicing. Failure to follow this caution will cause personal injury. h. Close the gate valve (D). If it is not connected to a drain, install a cap (E) on the outlet pipe (F). Note: Remove the cap (E) when the gate valve (D) is used for test or pressure relief. Recap when the test or pressure relief is complete.! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. F E D 5

i. Install a pipe union (G) on the inlet pipe (). G 3. Position the bucket trap so that the cover (J) is on top and the inlet pipe () will connect with the IN tapping on the body (H). J H 4. Install the bucket trap (K) on the inlet pipe () as positioned in tep 8. K For Applications with a Return Line 5. Install a tee fitting (L) on the return line (K) near the trap outlet (H). K L H 6a. Install a gate valve (M) on the outlet pipe (N) for test or pressure relief. b. Close the gate valve (M). N M 6

7. If the gate valve (M) is not connected to a drain, install a cap (P) on the outlet pipe (N). Note: Remove the cap (P) when the gate valve (M) is used for test or pressure relief. Recap when the test or pressure relief is complete. N M P! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. For Applications with a Gravity Return, Pressurized Return or Return Line Above the Trap Discharge 8. Install a check valve (R) on the return line (K). K R For All eries 0, 1, 2, 3 & 4 Applications 9. Install a shut-off valve () on the return line (K). K 7

10. Depending on your application, complete one of the following steps: a. Connect the return line (K) to a drain (T) T K OR b. Add a gravity return line (U) U OR c. Add a pressured return (V) or a return line above the trap discharge (W). A check valve (R) (see tep 8) must be installed for pressurized returns and return lines above trap discharge. R W V 11. Prime the bucket trap as follows while the equipment is operating: a. Close the shut-off valve () on the return line (K) for (1) one minute. b. lowly open the shut-off valve () on the return line (K). K INTALLATION COMPLETE 8

ERIE 6 INVERTED UCKET TRAP 1. Determine where to install the trap, based on the following requirements: a. The trap must be located as close as possible and below the equipment to be drained. b. The trap must be in a straight run of vertical pipe. Refer to the Typical Piping Diagram at the right. c. Plenty of space around the trap is needed for servicing, which may include removal of the body or cover. TYPICAL PIPING DIAGRAM Trap Draining to Main Return Line Above or elow Trap Discharge tatic Head Equipment Drain Point Gate Valve For Test & Pressure Relief afety Cap Inlet Pipe Pipe Elbow Pipe Union Check Valve Return Line ucket Trap Main Return Line hut-off Valve tatic Head Against Discharge 1 /2 psi/ft. (.035 bar per.3m) Main Return Line hut-off Valve Pipe Union Inlet Pipe Tee Fitting Dirt Pocket Y trainer Gate Valve For low Down Pipe Elbow 2. Install near trap piping: a. Install a shut-off valve (A) on the inlet pipe (). b. Install a Hoffman pecialty Y trainer (C) on the inlet pipe (). A c. Install a gate valve for blow down (D) by connecting it to the Y trainer drain tapping (C). C D 9

d. Cap off the outlet pipe (X). e. lowly turn steam on with full pressure for (5) five minutes to blow down the inlet pipe (). f. Turn off steam and allow pipe to cool. g. Remove cap from the outlet pipe (X).! WARNING To prevent serious personal injury from steam pipe blow down, connect a temporary pipe between the steam pipe opening and a drain, or stand at least 100 ft. (30m) from the pipe opening. Failure to follow this warning could cause property damage, personal injury, or death. D X Pipe Opening! CAUTION To prevent serious burns, the internal pressure of the trap must be 0 psi (0 bar) before servicing. Failure to follow this caution will cause personal injury. h. Close the gate valve (D). If it is not connected to a drain, install a cap (E) on the outlet pipe (F). Note: Remove the cap (E) when the gate valve (D) is used for test or pressure relief. Recap when the test or pressure relief is complete. F E D! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. i. Install a pipe union (G) on the inlet pipe (). G j. Install a pipe elbow (H) on the inlet pipe (). H 10

3. Position the bucket trap so that the cover (J) is on top and the inlet pipe () will connect with the bottom inlet tapping (K). J K 4. Install the bucket trap (L) on the inlet pipe () as positioned in tep 9. L 5. Remove the 1/2" (15mm) pipe lug (L) on the trap cover (J). L J 6. Connect an outlet pipe (M) on the tapping where the pipe lug was removed. M N P 7. Install pipe elbows (N) and (P) on the outlet pipe (M). M 11

8a. Install a gate valve (Q) on the outlet pipe (M) for test or pressure relief. b. Close the gate valve (Q). Q M 9. If the gate valve (Q) is not connected to a drain, install a cap (R) on the outlet pipe (M). Note: Remove the cap (R) when the gate valve (Q) is used for test or pressure relief. Recap when the test or pressure relief is complete. Q R M! WARNING To prevent property damage, personal injury, or death, cap off the gate valve if it is not connected to a drain and when it is not in use for test or pressure relief. Failure to follow this warning could cause property damage, personal injury, or death. 10. Install a return line () in the trap outlet tapping (T). T 11. Install a pipe elbow (U) on the return line (). U 12

12. Install a pipe union (V) on the return line (). V 13. Install a check valve (W) on the return line (). W 14. Install a shut-off valve (X) on the return line (). X 13

15. Depending on your application, install a pipe elbow to the trap return line () and connect it to: Y a. A main return above the trap discharge (Y). OR Z b. A main return below the trap discharge (Z). 16. Prime the bucket trap as follows once the equipment is operating: X a. Close the shut-off valve (X) on the return line () for (1) one minute. b. lowly open the shut-off valve (X) on the return line (). INTALLATION COMPLETE 14

MAINTENANCE When checked regularly and properly maintained, the eries Inverted ucket team Traps will provide optimum performance and long life. CHEDULE: Initially, every 2-3 days after start-up until system is clean. Every 6 months thereafter.! CAUTION To prevent serious burns, the internal pressure of the trap must be 0 psi (0 bar) before servicing. Failure to follow this caution will cause personal injury. 1. Inspect joints for leaks. top all leaks by tightening bolts and replacing gaskets, if necessary. 2. Clean strainers by opening the blow down valve and allowing full steam pressure to flow out for (2) two minutes. Then, close the valve. 3. Test traps by following the Troubleshooting procedure. 15

TROULEHOOTING We recommend trap replacement when parts no longer operate properly. A new trap is more economical than repairing or replacing parts and it will provide greater Problem: 1. Improper Heating a. Cause: The bucket bleed hole is plugged, trapping air in the top of the bucket. Test: Using a stethoscope, listen for a gurgling sound in the trap. No gurgling indicates the condensate is not draining. olution: Disassemble the trap and unclog the bucket bleed hole. b. Cause: The steam pressure is higher than the bucket trap s seat rating pressure which prevents the trap from opening. Test: Check the seat pressure rating on the bucket trap nameplate with the available steam pressure to the equipment being drained. olution: Install a new Hoffman pecialty Inverted ucket ear Trap with the proper pressure range. Note: The trap must be selected for the maximum differential pressure that will be encountered. A high pressure seat may be used at lower differential pressures, but the capacity rating will be less than an identical size trap with a low pressure rated seat. reliability. If you choose to repair the trap, order Hoffman pecialty replacement parts and follow the Repair Procedure provided. Problem: 2. Energy Wasted a. Cause: A worn pin and seat or dirt deposited on the seat prevents tight closure. Test: Using a stethoscope, listen for a low pitch whistle sound. A low pitch whistle sound indicates the trap is open and blowing live steam. olution: Disassemble the trap and inspect for dirt or worn parts. Clean if dirty or install a new Hoffman pecialty Inverted ucket ear Trap if worn. b. Cause: The trap does not close because the linkage detached from the bucket assembly. Test: Using a stethoscope, listen for a low pitch whistle. A low pitch whistle indicates the trap is open and blowing live steam. olution: Disassemble the trap and inspect for worn parts. If worn, install a new Hoffman pecialty Inverted ucket ear Trap. c. Cause: Full capacity drainage is prevented by worn linkage. Test: Disassemble the trap and inspect for worn parts. olution: Install a new Hoffman pecialty Inverted ucket ear Trap. 3500 N. paulding Avenue Chicago, Illinois 60618 tel: 773 267-1600 fax: 773 267-0991 www.hoffmanspecialty.com 2003 ITT Industries, Inc. Printed in U..A. 3-03 510900