Intelligent Security & Fire Ltd

Similar documents
Sigma. K1000 Series 1, 2, 4 & 6 Zone Fire Control Panels. Operation and Maintenance Manual. Man-1048 Issue 05 October 2009

Installation, Operating and Maintenance Manual

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

PNC 1000 SERIES 2, 4, 8 Zone Fire Alarm Control Panel

Excel-EN Conventional Fire Control Panel

Control Panel Engineering and Commissioning Instructions

Saffire User & Installation Manual. IMPORTANT This manual should be left with the panel after installation.

Precept Marine Control Panel Application Guide

USER MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4

Application, Installation, Operation & Maintenance Manual

BT1 SINGLE ZONE FIRE ALARM SYSTEM OPERATORS MANUAL

Hydrosense. Vimpex Limited. Star Lane. Great Wakering. Essex SS3 0PJ. Tel: +44 (0) Fax +44 (0)

FTEN1, FTEN2, & FTEN4 1, 2 & 4 ZONE FIRE DETECTION AND ALARM CONTROL PANELS

User Operation Manual

LC1 & 2. Fire Alarm Panel 6\VWHPLQVWDOODWLRQRSHUDWLQJ PDLQWHQDQFH LQVWUXFWLRQV

Surveyor Envoy-MINI 4

1200-HCM DIN RAIL MOUNTING FIRE SYSTEM MODULE Fire Detection & Extinguishant Control A R T PATOL LIMITED SUPPLY FAULT SOUNDER

INTELLIGENT FIRE TECHNOLOGY. Twinflex and Multipoint V3. User Guide (TO BE RETAINED BY USER) Issue 3

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

SOLO Single Loop Addressable Fire Control Panel

FIREBETA EXTINGUISHING CONTROL PANEL (ECP)

OPERATION AND INSTALLATION MANUAL

909e Series 2/4 Zone Panel. Operating and Configuration. Manual Version V01

Intelligent Security & Fire Ltd

MINERVA MX. 800 Series Ancillary Equipment

3200 NON-ADDRESSABLE FIRE ALARM CONTROL PANEL

6100 SINGLE LOOP DIGITAL ADDRESSABLE FIRE ALARM CONTROL PANEL

Surveyor Excel. Fire Alarm Control Equipment Network version. Programming Manual MASTER MANUAL. VERSION 14.0 and Above

Fire Control Panel. Installation & Programming Manual TABLE OF CONTENTS

Conventional Fire Alarm System 2014 V1.2

Fire Alarm Control Panel. System Maintenance and Log Book

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

MAG2/4. AL MAG2 Soft. Version 2.1 MAG4 Soft.Version 2.0 USER MANUAL

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

3500 CONVENTIONAL FIRE ALARM CONTROL PANEL

NZ 400 AUTOMATIC FIRE ALARM SYSTEM OPERATORS MANUAL

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

Smoke Vent Control Panel PCB4 V4 Installation Manual

Doc. No.: OMPII.DOC Rev. 2 Written By: Raj Patel Checked By: AJC Approved By: JBJ Date: 03/05/05

System 800 Addressable Fire Detection & Alarm System

ED820-24V MODEL INSTRUCTION MANUAL. fire DETECTOR

BiWire Flexi. BiWire Flexi Fire Panel EFBW8ZONE-FLEXI / EFBW4ZONE-FLEXI / EFBW2ZONEFLEXI Installation Manual

Technical Data Sheet

FIRE ALARM CONTROL PANEL FVC01-08

Conventional Fire Control Panel

The ID51 & ID52 can be upgraded to 2 loops without the need to change back box. FEATURES. Intelligent Features

Conventional Fire Control Panel (FKEP2, FKEP4, FKEP8) Operation and Maintenance Manual. Man-1078EL Issue 01 February 2014

Conventional & Twin-wire Fire System

Discovery 1-4 Loop 32 Zone, 40 Character Analogue Addressable Control Panel. Application Guide

Matrix2000. User Guide - CPD Advanced Analog Fire Alarm Control Panel 4 24 Zones. Version: 2.0 Revision: 1

Installation and Operating Instructions

Panel Functions & Indicators - Key to Icons General & Zone Fire LEDs ACCEPT SOUNDERS START/ STOP RESET BUZZER MUTE KEYSWITCH DELAY ON/OFF ITEM SELECT

PREMIER EX8 INSTALLATION MANUAL COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 & EN54 PARTS 2 & 4 INSTALLATION MANUAL

Conventional Leaflets

Operating manual and Log book for the range of 1,2,4 and 8 zone fire Control and Repeat panels

USER MANUAL & MAINTENANCE GUIDE OG OO

FSTP4-2-wire 4 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS4 Issue 01 April 2012

Prem1er EVACS16. Installation Manual VOICE ALARM CONTROL PANEL 4 16 ZONES

Intruder - Fire - Water Combined Alarm

Intelligent Security & Fire Ltd

Discovery 1-4 Loop 96 Zone, 40-Character Analogue Addressable Control Panel. Application Guide

4 wire conventional alarm system

Menvier Fire System MF9300

EX8. Instruction Manual: COMBINED FIRE & EXTINGUISHING CONTROL PANEL COMPLIES WITH BS EN PART 1 AND EN54 PARTS 2 & 4

End To End Optical Beam Smoke Detector. Additional Information

LEAKSTOPPER MULTIZONE WATER LEAK DETECTION ALARM PANEL INSTALLATION AND OPERATION MANUAL

FSTP2-2-wire 2 Zone Conventional Fire Control Panel Operation and Maintenance Manual. Man-1078FS2 Issue 01 April 2012

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

Conventional Fire Control Panel with Extinguishant Control Unit. Operation and Maintenance Manual SIGMA-2-M3-ECU SIGMA-4-M3-ECU SIGMA-8-M3-ECU

SECURIT 700L PLUS ENGINEERING MANUAL

Reflective Optical Beam Smoke Detector User Guide

FIREPRO INSTALLATION MANUAL FIRE ALARM CONTROL PANEL INSTALLATION MANUAL. Approved Document No. GLT Issue: 1. 8 Author: NRPJ Date: 7/ 3/201 4

VSN-RP1r Extinguishing Control Panel. User Manual (Software version 3.x) by Honeywell. doc. MIE-MN-570I rev.008

FIRE ALARM CONTROL PANEL. COMPLIES WITH EN54 part 2 & part 4 MEETS THE FUNCTIONAL REQUIREMENT OF BS:EN 5839 part 1 INSTALLATION MANUAL

Fire Control Panel FS4000

TS400 & TS410. Intruder Alarm Control Panels. Operating Instructions

Installation Instructions 4 Zone Fire Panel

INSTALLATION MANUAL SECURIT 802 CONTROL PANEL

Installation, Commissioning & Operating Manual

5000 INSTALLATION GUIDE

Sita200plus. 200detectors. Single loop analogue addressable System

SIMPLICITY CO CARBON MONOXIDE DETECTION & VENTILATION PANEL

EUROFIRE Fire Control Panel

Algo-Tec 6300 INTERACTIVE DIGITAL ADDRESSABLE FIRE CONTROL SYSTEM (1-4 LOOPS)

Scimitar user manual & log book. Petersfield Business Park, Bedford Rd, Petersfield, Hampshire GU32 3QA Tel: Fax:

FEC400 Series. Installation Manual

SYSTEM MANUAL FT1-SB. Single Zone Fire Alarm System

NFS Supra / VSN-2Plus / ESS-2Plus Conventional Fire Alarm Control Panel. Installation and Operating Manual

TECHNICAL DATA OBSOLETE

FIRE DETECTOR TYPE ED816 ZONE 5 ZONE 4 ZONE 6 ZONE 7 FIRE FIRE FIRE FIRE FAULT FAULT FAULT FAULT DISABLED DISABLED DISABLED DISABLED OFF OFF OFF OFF

GAS SUPRESSION CONTROL PANEL:

ORION Mini-Rep INSTALLATION MANUAL

Control Panel Engineering and Commissioning Manual (TO BE RETAINED BY THE COMMISSIONING ENGINEER)

Installation Guide for AL800UL-ADA. NAC Power Extender. Rev

Fire Control Panel FS4000

DYCU-3 AEROSOL FIRE EXTINGUISHER CONTROL UNIT OPERATION MANUAL

PRODUCT INSTRUCTIONS. Fire Door Control Panel (FDCP) Stock Code Description Doc No: PI-115. Ellard Fire Door Control Panel Ellard Slave Repeater Unit

Operation and Maintenance Manual

ANALOX 5001 Carbon Dioxide Monitor. User Manual ANALOX Analox 5001 Carbon Dioxide Monitor User Manual

Transcription:

OPERATIONAL NOTES FOR CONCEPT FIRE PANEL. NOTE ON NEW FIRE PANELS, POSITION 1 ON THE SIX WAY INTERNAL OPTION SWITCH IS TURNED ON, DISABLING THE ZONAL SOUNDERS. TO ENABLE ZONAL SOUNDERS TURN OFF. Operation of fire panel. Normal operation: The green LED is illuminated indicating system healthy. All other LED s are off. Fire condition: Triggered off by a smoke detector or a break glass operation and is indicated by a red LED showing common fire and a red LED showing the zone in fire, accompanied by a constant tone from the panel and the operation of zonal sounders and sounder circuits. Evacuate. Operation of the evacuate or remote evacuate will trigger all sounders. The remote evacuate is a none latching input. Silence. To silence the sounders, press the silence button having first enabled the controls with the keyswitch. The sounders will cease to operate and the panel buzzer will pulse to indicate that the silence has been pressed. Auxiliary relay ( reset on silence ) will be reset. Reset/ Lamp test. The reset button will perform a lamp test of all LED s which should illuminate in sequence. It also resets the processor, resets the detectors, resets any fire condition that may be latched, resets buzzer if in operation, resets all auxiliary relays and resets sounders. If a fire condition or fault persists after reset, the circuit will redisplay the condition. If a fire condition exists the sounders will come on even if they were silenced previously. When a fire condition is indicated, the source of the detection should be investigated before reset is pressed in order to locate the smoke detector triggering the system. ( the smoke detector operating will have an LED illuminated on it.) If there is a residue of smoke in the area, the smoke detectors may reactivate after reset, In this case try again after a short time. One man test In this mode the unit will reset every 10 seconds. This will enable the detectors to be tested without the need to return to the unit to reset the detectors. Whilst in this mode, the fault lamp will come on and the buzzer will pulse. The silence function will not operate. The zones, sounders, relays and remote input can all be isolated from the front controls by pressing the mode button and selecting or clearing the operation by pressing the set/clear key. A constant indicator shows that function has been selected. (A flashing indicator shows it has been cleared). To isolate a zone first select the zone isolate function, further presses of the mode key enable isolation of the individual zone in the same manner as before. When the appropriate isolation has been selected, pressing reset returns the panel to normal operation. If no keys are pressed for 25 seconds the panel will automatically reset. One man test may be selected also by pressing the mode button and selecting or clearing by pressing the set/clear button, followed by pressing reset. See the Mode selecting/ clearing instruction sheet for further detail. 1

The zones are monitored for short circuit, shown by a constant LED on zone fault. open circuit gives flashing LED on zone fault, flashing in time with the zone indicator LED. Head removal zone fault gives flashing LED in time with zone indicator LED but reverse flash rate to open circuit. Sounder circuits are also monitored for open /short circuit in the same manner. Sounder fuse fault gives flashing zone indicator and constant fuse indicator. Failure of the fuse does not effect zone monitoring. The fuses and head removal are monitored every 25 seconds. The sounder circuits are monitored for short circuit, constant LED on sounder fault and flashing LED for open circuit. Internally there is a set of six switches to alter the functions of the panel. Pos 1 Zone sounders inhibit In this mode the zonal sounders are turned off. This may be selected when the panel is used as a conventional panel where the sounders pulsing signal may cause a problem. Pos 2 Pre 1988 mode In this mode the panel operates to pre 1988 specifications, i.e. a short circuit gives a fire condition. This mode can be used when a panel is used with old detectors or even a mixture of old and new detectors. Note that in this mode there is no head removal and no zonal sounders operation. Pos 3 Non latch zone 1 In this mode zone 1 will not latch. This mode is used to operate the fire alarm panel from another panel, say in a landlord/tenant application. The landlord's panel can trigger a number of other panels to show fire, but they are reset when the landlord's panel is reset. Pos 4 None latch zone 2 In this mode zone 2 will not latch. This mode is used to operate the fire alarm panel from another panel, say in a landlord/tenant application. The landlord's panel can trigger a number of other panels to show fire, but they are reset when the landlord's panel is reset. Pos 5 Sounder delay In this mode in fire condition operation of zone sounders and sounder circuits 1 and 2 are delayed for two minutes. Sounders 3 and 4 are instant. Pos 6 Zone 1 lamp and buzzer only In this mode when zone 1 is triggered, will only give lamp and buzzer indication on the panel. No sounders or relays will be activated. 2

3 reset/ reset/ reset silence fault Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 Z9 Z10 Z11 Z12 rem S1 S2 S3 S4 reset/ zone remote sounder reset fuses evac fuse fuses 1 1 amp 1 amp 1 amp 1 option switches repeater 6 outputs 12 mode select 24v output fuse 24v + evac silence reset enable key Technical specifications. wiring to psu board battery fuse power fuse battery start Detector zones and sounder circuits - 4K3 end of line resistor. Up to 12 zones. 20 detectors per zone, 15 two wire sounders per zone with a maximum of 70 two wire sounders across all zones. 4 Sounder circuits - normally reverse polarity, in alarm 24v fused at 1 amp per sounder circuit. Power supply rated at 2 amps. Battery charger capable of charging 2 x 12v 7AH batteries. Charging voltage 27.6 volts. Batteries protected from full discharge by battery protect relay. This relay prevents the panel being powered up on batteries only at commissioning. To override this there is a push button on the back board to start the panel on batteries only. The battery and power supply fuses are also situated on this rear board. Control panel consumption 110 ma max. 2 Auxiliary relays, with 3 sets of volt free changeover contacts rated at 2 amp max. two operate on fire, reset on reset. One operates on fire, reset on silence. 1 Fault relay, with one set of volt free changeover contacts. 24 volt d.c supply for beam detectors etc. Repeater output connections.

4 MODE SELECTING / CLEARING. MODE SET/CLEAR RESET ISOLATE ZONE 1 OR WILL RESET 2 AFTER 25 SECONDS 3 SELECT 4 5 6 7 8 9 10 11 12 SOUNDERS RELAYS/OUTPUTS REMOTE INPUT ONE MAN TEST To select zone isolation 1. First press mode, Note, the zone isolation light will be flashing. 2. Press set/clear, the light will become constant. 3. Press mode, the zone light will now be flashing. 4. Continue pressing the mode button until you get to the zone required. 5. Press set/clear, the light will become constant. 6. Press reset, The zone is now isolated. To select other modes. 1. First press mode, Note, the light will be flashing. 2. Then continue pressing it, rotating round the options, until the one wanted. 3. Press set/clear, the light will become constant. 4. Press reset, the mode selected is now set. To clear zone isolation. 1. First press mode, Note, the zone isolation light will be flashing. 2. Press set/clear, the light will become constant. 3. Press mode, the zone light will now be flashing. 4. Press reset, the mode is now cleared. To clear other modes. 1. First press mode, Note, the light will be flashing. 2. Press reset, the mode is now cleared.

5 4K3 End of line Monitoring 4K3 End of line Resistor on the last resistor on last device on Device. A minimum of 2 sounder each zone. Circuits must be used. 4K3 End of line Monitoring resistor on last device on each zone. Remote evacuate. This input can be used to sound the alarms from a remote source by introducing a 470 ohm resistor across the line. A 4K3 end of line resistor must be fitted. E + - E + - E + - E + - + - + - + - + - 1 2 3 REVAC S1 S2 S3 S4 Zones Remote evacuate CONVENTIONAL PANEL CONNECTIONS. 4K3 End of line Resistor on the last Device. 2 wire sounder Remote evacuate. This input can be used to sound the alarms from a remote source by introducing a 470 ohm resistor across the line. A 4K3 end of line resistor must be fitted. sounders E + - E + - E + - E + - + - + - + - + - 1 2 3 REVAC S1 S2 S3 S4 Zones 2 WIRE SOUNDER PANEL CONNECTIONS Remote evacuate sounders

2 WIRE SOUNDER WIRING DIAGRAM FOR FULLEON 2 WIRE SOUNDERS RED BLK L1 0V +VE OUT L1 IN APPOLLO SERIES 60 E DIODE -R - + ZONE + - TO NEXT SOUNDER / DETECTOR L2 BASE THE DETECTOR BASE IS SCREWED ONTO THE SOUNDER USING THE SCREWS PROVIDED. CONNECT THE WIRES ON THE SOUNDER TO L1 IN AND L2 ON THE DETECTOR BASE AS SHOWN ON THE WIRING DRG. UP TO 15 TWO WIRE SOUNDERS CAN BE WIRED TO EACH ZONE, WITH A MAXIMUM OF 70 TWO WIRE SOUNDERS ACROSS ALL ZONES. AN END OF LINE 4K3 RESISTOR MUST BE FITTED ON LAST SOUNDER OR DETECTOR. 2 WIRE SOUNDER RED BLK +ve 0V +VE OUT ( 1 ) HOCHIKI YBN-R/4SK BASE +ve IN ( 2 ) DIODE -R ( 5 ) -ve IN ( 3 ) E ( 6 ) BASE -ve OUT - + ZONE + - TO NEXT SOUNDER / DETECTOR THE DETECTOR BASE IS SCREWED ONTO THE SOUNDER USING THE SCREWS PROVIDED. CONNECT THE WIRES ON THE SOUNDER TO 2 AND 5 ON THE DETECTOR BASE AS SHOWN ON THE WIRING DRG. UP TO 15 TWO WIRE SOUNDERS CAN BE WIRED TO EACH ZONE, WITH A MAXIMUM OF 70 TWO WIRE SOUNDERS ACROSS ALL ZONES. AN END OF LINE 4K3 RESISTOR MUST BE FITTED ON LAST SOUNDER OR DETECTOR 6

Installation and Commissioning General This section should be read fully before commencing wiring and installation of the fire panel. The FireSense range of fire panes has been designed to comply with BS 5839 : Part 4 : 1988 Fire detection installations should be designed in accordance with BS 5839 : Part 1 :1988. The choice of cables used is dependant on the installation and should comply with BS 5839 : Part 1 : 1988. Cables should be installed in accordance with the current edition of the IEE Wiring regulations (Regulations for electrical installations, published by the Institute of electrical engineers) (BS 7671 : 1993). Sounder Wiring Mineral insulated copper cable or similar fire proof can mechanically resilient cable should be used for alarm sounder circuits, as indicated in BS 5839 : Part 1 : 1998. Section Two 17. A minimum of two sounder circuits should be used in each installation to comply with BS 5839 : Part 1 : 1988 Sounder output circuits should be wired as continuous pairs with no spurs or tees. An end of line device should be fitted to each sounder circuit as shown in Fig. 1.1. below. + Ensure correct diode polarity _ Last Unit Fig. 1.1 Typical sounder circuit End of line Resistor Detector Wiring The cable used is dependant on the installation, as indicated in BS 5839 : Part 1 : 1988 Section Two 17. An end of line device should be fitted to the end of each zone circuit. Unused zones require and end of line device connecting across the zone input terminals to prevent an open circuit fault from being indicated on the control panel. When the detector removed facility is required a diode should be fitted in each detector base as detailed on Fig. 2.2 taking care to observe the correct polarity. Refer to individual manufacturers data for details on detector terminals and wiring, some manufacturers allow for an in line device to be fitted in the negative line. + End of Line Resistor + in + out In-line Diode Last Unit _ Ensure Correct Polarity Fig. 1.2 Detector Wiring diagram 7

Call points To comply with BS 5839 : Part 1 : 1988 Resistive call points should be used on the installation to differentiate between a fire condition (a resistor ) and a short circuit. Old installations work on a short circuit as a fire condition. If a FireSense panel is to be used on an old installation e.g. short circuit call points either resistors are needed in line with the call points (470R or 680R) or alternatively, if it is not a requirement to bring the system up to date the panel can be switched to treat a short circuit as a fire condition. Failure to do this will cause the panel to go into short circuit instead of fire, on operation of the call point. + _ In line Resistors Last Unit Fig. 1.3 Call point Wiring diagram with in line resistor End of Line Resistor Call points normally come with integral resistors and so no extra resistors are required. 8