PT700. Product Information

Similar documents
EP5 Electropneumatic positioner

D3 Digital Positioner. Product Information

D3 Digital Positioner. Product Information

Worcester Controls PS/PM Series UltraSwitch. Switchbox

Valtek Guardian II Metal Bellows Seal Valtek Guardian II

Limitorque FR Shells Removable Intumescent Fireproof Coatings

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

Automax XCL Series UltraSwitch. Switch box

Automax PS/PM Series UltraSwitch. Switchbox

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

Flowserve Logix. 420 Digital Positioner. Experience In Motion. Redefining low cost ownership for your enterprise

Model 144H. Product Data Sheet , Rev DB February Content

Experience In Motion. SIHI LEMD Compact Liquid Ring Vacuum Pump

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Model 144H. Product Data Sheet , Rev DB February Content

Guardian II Metal Bellows Seal. Valtek Guardian II Metal Bellows Seal Control Valves

STT 3000 Series STT250 /150 Surge Protection Device Specifications

PT9420 (Extended Range)

MSM400 Ultrasonic Suspended Solids Monitoring and Control System

micropac. Personal Gas Detection Instruments

Level instruments. Point level measurement - Capacitance switches. Pointek CLS100 5/9. Overview. Configuration

Dräger X-am Dräger X-am 3000: Designed for the harshest industrial environments.

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Dräger Polytron 5720 IR Toxic Gas Detection

Dräger Polytron 7000 Fixed gas detector

Dräger PIR 3000 Detection of flammable gases and vapours

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Annubar Flowmeter Series

PT9600. Cable Actuated Encoder Reel. General. Environmental

VersaFlow Coriolis 100 Mass Flow Sensor Technical Datasheet. Specification

The A-series Eletta Flow Monitor with local indication and analog output

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Rosemount 2090P Pulp and Paper Pressure Transmitter

Pac Ex 2. Elegant and smart Explosive hazards and lack or surplus of oxygen under control

Rosemount 4500 Hygienic Pressure Transmitter

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

ATEX. Tough controls for tough environments. ia.danfoss.com. Brochure Controls. Danfoss controls - designed and approved for hazardous areas

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Logix Positioner Overview July 2015 Barrancabermeja. Ruben Izarra

Dräger PIR 7000 Flammable Gas Detection

Level Measurement. Point level measurement Capacitance switches. Pointek CLS100. Overview. Configuration

Rosemount 3100 Series Ultrasonic Level Transmitters

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Rosemount 2090F Sanitary Pressure Transmitter with HART Protocol

Dräger Polytron 8720 IR Detection of carbon dioxide

Ultrasonic Level Measurement nivopuls FDU 10 S

Level Measurement. Point level measurement - Capacitance switches. Pointek CLS100. 5/10 Siemens FI Overview.

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

Dräger Polytron 5720 IR Detection of carbon dioxide

Rosemount 2090F Hygienic Pressure Transmitter

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

ATEX Installation Instructions for Micro Motion F-Series Sensors with Certificate DMT 01 ATEX E 158 X

DL424/425 DirectLine Sensor Module for Dissolved Oxygen Probes Series DL5000 Specifications

LOW PRESSURE Intrinsically Safe Transducer AST44LP

Level gauges Series LS Level indicator, switch and transmitter for liquids

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

3M Oldham OLCT 100. Description. Fixed Gas Detector

Dräger PIR 7200 Toxic Gas Detection Transmitter

M7100 Pressure Transducer

PROFIBUS-PA Display RID 261 PROFIBUS-PA

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

PT9101. General. Potentiometer Cycle Life 250,000 Maximum Retraction. Weight, Aluminum (Stainless 8 lbs. (16 lbs.) max. Electrical

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

RADAR LEVEL GAUGE SPECIAL SAFETY INSTRUCTION

Dräger PIR 7200 Detection of toxic gases and oxygen

FF-SR Series. FF-SR25933 Two-hand Safety Control Module FF-SR25933

custom cabinets and junction boxes

Dräger Polytron 8200 Stationary gas detector (CatEx)

GESTRA Steam Systems LRG English. Installation Instructions Conductivity Electrode

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Enraf Servo Gauge 854 XTG

VICOTEC450 EXTRACTIVE VISIBILITY MEASURING DEVICES EXTRACTIVE VISIBILITY MEASUREMENT FOR INCREASED SAFETY IN TUNNELS

D5100 Industrial Differential Pressure Transducer

Temperature Measurement Transmitters for field mounting

Dräger Polytron 8310 IR Detection of flammable gases and vapour

PT9150 (Extended Range)

Dräger Polytron 8310 Stationary gas detector (DSIR)

D5100 Industrial Differential Pressure Transducer

Enraf Servo Gauge 854 ATG

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

OPTIBAR DP 7060 Supplementary Instructions

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

DSF xx15.xx xhv Ex-Atex Ex-Atex Certified Two wire Hall Effect Speed Sensor

Dräger REGARD -1 Control System

FAHM Co. Temperature Transmitter PTT74 Series

RFM Series RFM-ISR Barrier. Installation Manual

Rosemount 3100 Series Ultrasonic Level Transmitters

Dräger QuadGard Control System

POINTEK CLS 100 OINTEK CLS 100 CAPACITANCE LIQUIDS/SOLIDS. Instruction Manual March 2001

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sanitary Pressure Transmitter

Rosemount 752 Fieldbus Remote Indicator

DL423 DirectLine Sensor Module for Conductivity Measurement Specifications

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

Transcription:

PT700 Product Information

PT700 PT700 is a transducer for 4-20 ma input signal and with a high volume output of up to 4 bar. The output is monitored via pressure sensors, this makes PT700 ideal for installation on spring return actuators. Up to 4 bar output Flexible mounting Fits Rotary & Linear actuators IP66/NEMA 4X enclosure Easy calibration Add on gauge module VDI/VDE 3845 VDI/VDE 3847 5 1. 4 20 ma input signal 2. DIP switch configurator 3. Span/Zero adjustment 4. Gain adjustment 5. Cut off calibration 1 2 PT700 4 3 Intrinsically safe: ATEX II 1 G EEx ia IIC T4

Technical data Input signal 4 20 ma Split Range 4 12 ma, 12 20 ma Current supply min 3,6 ma Current supply max 100 ma Load 300 Ohm at 20 ma Voltage min 6 V DC Voltage max 9,5 V DC Air supply 1,5 6 bar Out put 0 4 bar Air supply quality Free from oil, dust and moisture ISO 8573-1, Cl. 1,2 Ingress protection IP66/Nema 4X Operating humidity 0 95% rh Air connections ¼ NPT Cable entry 2 x ½ or M20 x 1,5 Terminals Screw terminals 2,5 mm2 (AWG 14) Operating Temperature -20ºC to +85ºC -40ºC to +85ºC (optional) Storing temperature -40ºC to +85ºC Air delivery capacity 7 Nm3/h @ 6 bar Air consumption 0,12 Nm3/h @ 6 bar Linearity <1% Sensitivity <0,1% Repeatability <0,2% Dead band <0,1% Hysteresis <0,5% Temp effect <0,5%/10K Mounting position <0,25% Vibration sensitivity <1% at 1 & 2 g 3-300 Hz acc. IEC 61514 CE 84/336 EEC Approvals ATEX II 1 G EEx ia IIC T4 Housing material Die cast Aluminium Surface treatment Powder paint Soft goods Nitrile Weight 1,5 kg

Flowact VDI/VDE 3847 Modular PT700 with optional mounting brackets and gauge block.

Dimensions (mm) Base Transducer Model PT 7 0 0 - A B C - D PT 0 0 Standard, no approval PT 1 5 Intrinsically safe, ATEX II 1 G EEx ia IIC T4 Mark your choise: A= Housing W : Aluminum, Black w/ white cover, no window Y B : Aluminum, Black w/ yellow cover, no window : Aluminum, Black w/ black cover, no window B= Threaded connections 1 1/2 NPT conduit, 1/4 NPT pneumatic 2 M20 x 1,5 conduit, 1/4 NPT pneumatic C= Operating temperature S Standard -20 C to 80 C (-4 F to 176 F) E Extended -40 C to 80 C (-40 F to 176 F) D= Gauge options 0 No gauges 1 Output, PSI/BAR/KPA Stainless with brass internals 2 Output + Supply, PSI/BAR/KPA Stainless with brass internals 3 Output, PSI/BAR/KPA Stainless with stainless internals 4 Output + Supply, PSI/BAR/KPA Stainless with stainless internals Mounting options p/n A Flowact Direct mounting 30144 B VDI/VDE 3847 Direct mounting 30145 C IEC 534-6 Namur linear mounting 30168S D Wall / 2 pipe mounting bracket D3R-AS6

p/n: FCD PMENBR0009-02 Hazardous Locations ATEX II 1 G EEx ia IIC T4 Palmstierna International AB Korta Gatan 9 SE-171 54 Solna SWEDEN Tel: +46 (0) 8 555 106 00 Fax: +46 (0) 8 555 106 01 E-mail: infopmv@flowserve.com Mandersheidtstrasse 19 45141 Essen GERMANY Tel: +49 (0) 201 8919 5 Fax: +49 (0) 201 8919 662 12, av. du Québec 91965 Courtaboeuf Cedex FRANCE Tel: +33 (0) 1 60 923 251 Fax: +33 (0) 1 60 923 299 Ambachtsstraat 15 3176 PR Poortugaal THE NETHERLANDS Tel: +31 (0) 10 254 1050 Fax: +31 (0) 10 254 1055 Kassernengasse 6 9500 Villach, Carinthia AUSTRIA Tel: +43 (0) 424241 181 0 Fax: +43 (0) 424241 181 50/51 Via Prealpi, 30 20032 Cormano (Milano) ITALY Tel: +39 (0) 2 663 251 Fax: +39 (0) 2 615 18 63 Av. Dr Antunes Guimaraes 1159 Porto 4100-082 PORTUGAL Tel: +351 22 619 8770 Fax: +351 22 619 7575 Rätt Grafiska AB Ordernr: 23135 Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this product is designed to perform its intended function safely during its useful life. However, the purchaser or user of products should be aware that products might be used in numerous applications under a wide variety of industrial service conditions. Although can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of products. The purchaser/user should read and understand the Installation and Maintenance (I & M) instructions included with the product, and train its employees and contractors in the safe use of products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes onlyand should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construedas a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because is continually improving andupgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Corporation at any one of its worldwide operations or offices. 2007 Corporation, Irving, Texas, USA. and PMV are registered trademarks of Corporation. 1350 N Mt. Springs Prkwy. Springville, UT 84663 USA Tel: +1 801 489 8611 Fax: +1 801 489 3719 Unit 1, 12 Director Road Spartan Ext. 2 1613 Kempton Park, Gauteng SOUTH AFRICA Tel: +27 (0) 11 397 3150 Fax: +27 (0) 11 397 5300 No. 12 Tuas Avenue 20 REPUBLIC OF SINGAPORE 638824 Tel: +65 (0) 687 98900 Fax: +65 (0) 686 24940 C/O Saleh & Abdulaziz Abahsain P.O Box 209 Al Khobar 31952 SAUDI ARABIA Tel: +9663 857 3442 Fax: +9663 859 5284 Hanwei Building No. 7 Guanghua Road ChaoYang District 100004 Beijing CHINA Tel: +86-10-592 106 00 Fax: +86-10-656 127 02 www.pmv.nu