TECENICAL DATA. Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I. Wall mounted Type. DC Inverter E-Series

Similar documents
ON/OFF. Domestic Air conditioner. Wall mounted Type Arc-Series CAUTION HSU-14HR03/R2 HSU-18HR03/R2 1. READ THIS MANUAL CAREFULLY TO

SERVICE MANUAL. Wall Mounted Type ON/OFF T-Series HSU-07HUN103/R2-P WARNING. Haier Group Version V1 Date

DESIGN & TECHNICAL MANUAL

TECHNICAL DATA & SERVICE MANUAL

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624. Models HFC. Revision A: MUZ-FH50VE- E1 has been added. Please void OBH624.

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-HC25VA - E1 MUZ-HC35VA - E1 MUZ-HC35VA - E2 MUZ-HC35VAB - E1 MUZ-HC35VAB - E2 OUTDOOR UNIT. No. OBH467.

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUFZ-KJ50VE - E1, E2, ER1, ER2, ET1, ET2 MUFZ-KJ35VE OUTDOOR UNIT. No. OBH667. Models HFC

1 Features. Outdoor Units R-410A RYN-E3V1B. Split Sky Air Outdoor Units

technical data air conditioning systems FDKS-CVMB Concealed ceiling, Inverter Controlled Unit Split Sky Air

technical data air conditioning systems FTKS/FTXS-C FTKS/FTXS-B Wall Mounted, Inverter Controlled Unit Split Sky Air

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUZ-SF25VE MUZ-SF25VEH MUZ-SF35VE MUZ-SF35VEH MUZ-SF42VE MUZ-SF42VEH MUZ-SF50VE MUZ-SF50VEH OUTDOOR UNIT. No. OBH629 REVISED EDITION-E

SERVICE MANUAL MUZ-EF25VE MUZ-EF25VEH MUZ-EF35VE MUZ-EF35VEH MUZ-EF42VE MUZ-EF50VE. No. OBH590 REVISED EDITION-F. Models HFC

DESIGN & TECHNICAL MANUAL

technical data air conditioning systems FDXS-CVMB Concealed Ceiling, Inverter Controlled Unit Split Sky Air

SERVICE MANUAL OUTDOOR UNIT. No. OBH629 REVISED EDITION-A. Models HFC. Revision A: MUZ-SF25/35/42VE - E2 have been added. Please void OBH629.

MUZ-EF25VE - E1 MUZ-EF25VEH - E1 MUZ-EF35VE - E1 MUZ-EF35VEH - E1 MUZ-EF42VE - E1 MUZ-EF50VE - E1 Indoor unit service manual MSZ-EF VE Series (OBH589)

DESIGN & TECHNICAL MANUAL

TAC-09CS/K TAC-12CS/K TAC-18CS/K TAC-24CS/K TAC-07CHS/K TAC-09CHS/K TAC-12CHS/K TAC-18CHS/K TAC-24CHS/K

DESIGN & TECHNICAL MANUAL

technical data air conditioning systems FTXG-C Wall Mounted, Inverter Controlled Unit Split Sky Air

DESIGN & TECHNICAL MANUAL

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

SERVICE MANUAL MUZ-DM25VA - E1, ER1, ET1 MUZ-DM35VA - E1, ER1, ET1 OUTDOOR UNIT. No. OBH751. Models HFC R410A

SERVICE MANUAL MUZ-FH25VE MUZ-FH35VE MUZ-FH50VE OUTDOOR UNIT. No. OBH624 REVISED EDITION-E. Models HFC

Air Conditioner CONTENTS

TECHNICAL DATA & SERVICE MANUAL

TCL SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

technical data air conditioning systems FT(Y)S-B Wall Mounted Unit Split Sky Air

SERVICE MANUAL MUZ-HJ50VA - E1, E2, ER1, ER2, ET1, ET2 MUZ-HJ35VA - E1, E3, ER1, ER3, ET1, ET2

SERVICE MANUAL. Wall Mounted Type DC Inverter WARNING. Haier Group Version V1 Date

SERVICE MANUAL MUZ-GE50VA - E1 MUZ-GE50VAH - E1 MUZ-GE60VA - E1 MUZ-GE71VA - E1

DESIGN & TECHNICAL MANUAL

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

Split System Air Conditioning

Ductless Split Air Conditioner

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Ductless Split Air Conditioner

TECHNICAL DATA & SERVICE MANUAL

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

technical data air conditioning systems FVXS-FV1B R-410A Split Sky Air

AUTO COOL DRY FAN SPEED AIR SWING OFF ON TIMER TIMER OFF/ON FAN SPEED MODE TEMP AIR SWING TIMER ON SET OFF CANCEL AC RC SET CHECK CLOCK RESET

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER OUTDOOR UNIT: AE22AC/ACL/AH AE28AC/ACL/AH AE38AC/ACL/AH AE42AC/ACL/AH

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW22AL AW28AL AW38AL AW42AL AW22AL AW28AL AW38AL

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

Room Air Conditioner CONTENTS CS-E9BKP CU-E9BKP5 CS-E12BKP CU-E12BKP5. Order No: MAC C2

Content. Part 1 General Information Part 2 Indoor Units Part 3 Outdoor Units Part 4 Installation Part 5 Control...

DESIGN & TECHNICAL MANUAL

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

SERVICE MANUAL ROOM AIR CONDITIONER TAN/TAG-A28FWIS TAN/TAG-A32FWIS CONTENTS

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER CONTENTS. Models

SERVICE MANUAL. Wall Mounted Type DC Inverter FREE MATCH N-Series

8 Louver position display. 9 SWING display. 10 Set up temperature display. 11 Remote controller sensor display

TECHNICAL DATA & SERVICE MANUAL

EEDEN technical data ERHQ AA

SRK20ZFX-S, 25ZFX-S, 35ZFX-S, 50ZFX-S

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

TABLE OF CONTENTS ERSQ-AAY1

DESIGN & TECHNICAL MANUAL

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

CU-3E23CBPG, CU- 4E27CBPG,

SPLIT TYPE ROOM AIR CONDITIONER FLOOR CONSOLE / UNDER CEILING DUAL TYPE

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

SERVICE MANUAL OUTDOOR UNIT. No. OBH530. Models MU-GE50VB- E1 MUH-GE50VB- E1 HFC SPLIT-TYPE AIR CONDITIONERS R410A

SERVICE MANUAL. Model No. HSU09VHJ(DB) Wall mounted Type DC Inverter EA-Series WARNING. Haier Group. Order No.AC1101S020V0

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

TECHNICAL DATA & SERVICE MANUAL DISEGNO MACCHINA

PUHZ-SHW140YHA PUHZ-SHW230YKA

Destination Europe WARNING

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

SERVICE MANAUL. Wall Mounted Type DC Inverter FREE MATCH N-Series AS35NC2HRA

TECHNICAL & SERVICE MANUAL. Ceiling Concealed

Air Conditioners. Technical Data FTXS-G

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Product Data FEATURES AND BENEFITS. QHF 50Hz Heat Pump Inverter Single Phase 2.5kW to 8.0kW

TECHNICAL DATA & SERVICE MANUAL

TABLE OF CONTENTS. Air Conditioner. Indoor Unit Outdoor Unit CS-NE9LKE CU-NE9LKE CS-NE12LKE CU-NE12LKE CS-XE9LKE-5 CU-NE9LKE CS-XE12LKE-5 CU-NE12LKE

II PCV1 Features

DESIGN & TECHNICAL MANUAL

TABLE OF CONTENTS RMXS-E8V1B

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER (Split system, air to air heat pump type)

AIR CONDITIONER SERVICE MANUAL SPLIT WALL TYPE

SERVICE MANUAL. Wall Mounted Type DC Inverter FREE MATCH N-Series AS71NE1HRE

Change for Life. Service Manual

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

TECHNICAL CATALOGUE MONO SPLIT RAK-25PSC RAK-35PSC RAC-35WSC

DESIGN & TECHNICAL MANUAL

Inverter Wall Mounted Series

Transcription:

TECENICAL DATA Order No.AC0902T003V0 Wall mounted Type DC Inverter E-Series Model No. HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I 9K 12K 18K 24K 09K 12K 18K WARNING This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to service a product. Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any attempt to service or repair the product or products dealt with in this service information by anyone else could result in serious injury or death 24K 2008 (Qingdao Haier Air Conditioner General corp.,ltd) All right reserved.unauthorized copying and distribution is a violation of law Haier Group

Table of Contents Table of Contents 1. Features.......... 1 2. Specifications....... 2 3. Remote controller lists........ 7 4. Sensors lists........ 7 5. Dimensional drawings. 8 6. Operation range.... 12 7. Piping diagrams.... 13 8. Wiring diagrams. 14 9. Performance curves diagrams...... 17 9.1 Cooling capacity-temperature curves...17 9.2 Heating capacity-temperature curves...21 9.3 Cooling power consumption value curves...25 9.4 Heating power consumption value curves...29 9.5 Cooling discharge pressure cu rves...33 9.6 Cooling suction pressure cu rves...37 9.7 Heating discharge pressure curves...41 9.8 Heating suction pressure curves...45 10. Sound level... 48 11. Accessories... 52 12. Control systems.. 13. Center of gravity.. 53 55 14. Installations.. 59

Semi 1

2.Specifications This information was not available at the time of publication. HSU-09/12/18/24HEA03/R2(DB)-I Specifaications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I NOMINAL Cooling nominal kw 0.1 0.1 INPUT Heating nominal kw 0.1 0.1 NOMINALCA PACITY and NOMINA L INPUT NORMINAL CAPACITY(3-4) NORMINAL INPUT EER COP ANNUAL ENERGY CONSUMPTION(9) Model Cooling(1) Heating(2) Cooling Heating Cooling Heating Cooling min.~norm.~max. min.~norm.~max. min.~norm.~max. min.~norm.~max. kw kw kw kw kwh HSU-09HEA03/R2(DB)-I HSU-12HEA03/R2(DB)-I 1.25~2.81~4.3 1.25~3.72~4.8 1.3~2.93~4.5 1.3~3.9~5.0 0.35~0.78~1.55 0.35~1.1~1.85 0.32~0.8~1.52 0.32~1.14~1.71 3.60 3.38 3.66 3.42 390 550 TECHNICAL SPECIFICATIONS INDOOR UNITS DIMENSIONS WEIGHT COLOR SOUND LEVEL FAN Unit Unit Unit Sound pressure (cooling/heating)(5) Sound power(cooling/heating)(6) Air flow rate(cooling/heating) Speed(cooling/heating) Type Motor output H W D high medium low high high low super low steps high medium low mm mm mm kg db(a) db(a) db(a) db(a) m 3/min m 3/min m 3/min rpm rpm rpm W 9K 265 265 795 938 182 182 9.4 10.9 WHITE WHITE 39 34 30 50 41 38 36 52 8.8/9.6 10/10.8 7.9/8.7 8.75/9.6 7.1/7.9 7.5/8.3 4 steps,silent and auto 1300 1200 1175 1050 1050 900 Cross flow fan 18 12K HEAT EXCHANGER Type Row x stage x fin pitch mm ML fin - 7HI - XA tube 2 x 14 x1.4 AIR FILTER Removable/washable/mildew proof REMOTE CONTROLLER YR-H04 TEMPERATURE CONTROL Microcomputer control PIPING CONNECTIONS(external diameter) liquid gas drain mm mm mm 6.35 9.5 2 16 INSULATION MATERIAL Heat insulation type both liquid and gas pipes 2

Specifaications This information was not available at the time of publication. NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I NOMINAL Cooling nominal kw 0.1 0.1 INPUT Heating nominal kw 0.1 0.1 NOMINALCA PACITY and NOMINA L INPUT NORMINAL CAPACITY(3-4) NORMINAL INPUT EER COP ANNUAL ENERGY CONSUMPTION(9) Model Cooling(1) Heating(2) Cooling Heating Cooling Heating Cooling min.~norm.~max. min.~norm.~max. min.~norm.~max. min.~norm.~max. kw kw kw kw kwh HSU-18HEA03/R2(DB)-I HSU-24HEA03/R2(DB)-I 0.95~5.0~5.5 2.4~7.34~9.0 1.36~5.22~6.0 2.7~7.62~10 0.27~1.58~1.95 0.6~2.3~3.3 0.35~1.6~2.2 0.64~2.32~3.3 3.16 3.19 3.26 3.28 790 1150 TECHNICAL SPECIFICATIONS INDOOR UNITS DIMENSIONS WEIGHT COLOR SOUND LEVEL FAN Unit Unit Unit Sound pressure (cooling/heating)(5) Sound power(cooling/heating)(6) Air flow rate(cooling/heating) Speed(cooling/heating) Type Motor output H W D high medium low high high low super low steps high medium low mm mm mm kg db(a) db(a) db(a) db(a) m 3/min m 3/min m 3/min rpm rpm rpm W 18K 24K 265 938 320 1140 182 240 10.9 15.5 WHITE WHITE 44 41 38 52 47 45 40 61 13.3/14.1 21.6/22.4 12.1/12.9 19.8/21.6 10.9/11.7 18.1/18.9 4 steps,silent and auto 1400 1250 1275 1150 1150 900 Cross flow fan 40 HEAT EXCHANGER Type Row x stage x fin pitch mm ML fin - 7HI - XA tube 2 x 22 x1.4 AIR FILTER Removable/washable/mildew proof REMOTE CONTROLLER YR-H04 YR-H47 TEMPERATURE CONTROL Microcomputer control PIPING CONNECTIONS(external diameter) liquid gas drain mm mm mm 6.35 12.7 16 9.52 15.88 INSULATION MATERIAL Heat insulation type both liquid and gas pipes 3

Specifaications TECHNICAL SPECIFICATIONS OUTDOOR UNITS NET DIMENSIONS (stop valve, and bottom support is not included) WEIGHT COLOR SOUND LEVEL Unit Unit Unit H W D Sound pressure(cooling/heating)(5) high Sound power(cooling/heating)(6) high mm mm mm kg db(a) db(a) 9K 12K 543 783 255 543 783 255 33 33 white white 50 52 60 62 Air flow rate(cooling/heating) high m 3/min 26.6 FAN Speed(cooling/heating) high rpm 800 Type Propeller fan Motor output W 19 Refrigerant type R410a REFRIGERANT CIRCUIT Refrigerant charge Maximum allowable distance between indoor and outdoo Maximum allowable level difference Refrigerant control kg m m 0.98 1.12 15 10 capillary Type Rotary Compressor Model DA108X1C-20FZ3 COMPRESSOR Motor output w 855 Oil type ESTER OIL VG74 PIPING CONNECTIONS Oil charge volume liquid gas drain L mm mm mm 0.4 6.35 9.52 18 INSULATION MATERIAL Heat insulation type both liquid and gas pipes ELECTRICAL SPECIFICATIONS For combination indoor units+ outdoor units: 9K 12K Nominal running current cooling heating A A 3.5 3.5 4.9 5.0 Maximum cooling A 6.0 6.8 CURRENT running current heating A 6.0 7.0 Starting cooling A 26 26 current heating A 26 26 4

Specifaications TECHNICAL SPECIFICATIONS OUTDOOR UNITS NET DIMENSIONS (stop valve, and bottom support is not included) WEIGHT COLOR SOUND LEVEL Unit Unit Unit H W D Sound pressure(cooling/heating)(5) high Sound power(cooling/heating)(6) high mm mm mm kg db(a) db(a) 18K 24K 682 820 310 840 952 350 47 75 white white 52 61 62 71 Air flow rate(cooling/heating) high m 3/min 36.6 58.3 FAN Speed(cooling/heating) high rpm 800 900 Type Propeller fan Motor output Refrigerant type W 35 100 R410a REFRIGERANT CIRCUIT Refrigerant charge Maximum allowable distance between indoor and outdoo Maximum allowable level difference Refrigerant control kg m m 1.2 2.45 25 25 15 15 electronic expansion valve Type Rotary Compressor Model 5CS130XCC03 5CS160XAA23 COMPRESSOR Motor output w 900 1200 Oil type RB68A or Freol Alpha 68M FV50S PIPING CONNECTIONS Oil charge volume liquid gas drain L mm mm mm 0.4 6.35 12.7 18 0.6 9.52 15.88 INSULATION MATERIAL Heat insulation type both liquid and gas pipes ELECTRICAL SPECIFICATIONS For combination indoor units+ outdoor units: 18K 24K Nominal running current cooling heating A A 7.13 6.88 10.2 10.3 Maximum cooling A 10.2 14.4 CURRENT running current heating A 10.6 15.4 Starting cooling A 10 10 current heating A 10 10 5

Specifaications HSU-09/12/18/24HEA03/R2(DB)-I 6

Remote controller and sensor Model YR-H04 YR-H47 HSU-09/12/18HEA03/R2(DB)-I Y N HSU-24HEA03/R2(DB)-I N Y 7

5 dimensional drawings Indoor unit Dimentional drawings HSU-09HEA03/R2(DB)-I 795 265 182 HSU- /18HEA03/R2(DB)-I 938 265 182 8

Dimentional drawings HSU-24HEA03/R2(DB)-I 1140 320 570 757 240 860 9

682 HSU-09/12/18/24HEA03/R2(DB)-I Dimentional drawings Outdoor unit HSU-09/12HEA03/R2(DB) 255 2-w ay valve 6.35mm(1/4") 3-w ay valve 9.52mm(3/8") HSU-18HEA03/R2(DB)-I 820 310 60 146 317 80 584 10

Dimentional drawings HSU-24HEA03/R2(DB)-I 948 340 830 2-way valve 9.52mm(3/8") 3-way valve 15.88mm(5/8") 11

. HSU09/12/18HEA03/R2(DB)-I Operation range Cooling 50 46 40 43 Outdoortemp. DB 30 20 18 10 0 16 23 32 10 20 30 pull down indoor temp WB 25 24 20 Heating 15 WB outdoor temp 10 5 0-5 -10-15 Notes 10 20 30 indoor temp DB The graphs are based on the following condition Equivalent piping length 7.5m Level difference 0m Air flow rate high 12

HSU09/12/18HEA03/R2(DB)-I 13

8 Wiring diagrams HSU-09/12/18/24HEA03/R2(DB)-I Wring Diagramme HSU-09/12HEA03/R2(DB)-I Indoor unit INDOOR WIRING DIAGRAM 0010517987 transformer R W ion generator fan motor FUSE singal receiver board emergency switch Ambient temp.sensor Piping temp.sensor louver motor TO OUTDOOR UNIT B Black R Red BR Brown BL blue W White Y/G Yellow/Green Outdoor unit WARNING CAUTION DON'T TOUCH CAPACITOR, EVEN AFTER PLUG-OFF ( DANGER OF ELECTRIC SHOCK) The capacitor retains high voltage even after the plug-off. For your safety, be sure to wait at least 5 minutes. after plug off and use a tester to confirm the voltage between connector P DC FAN MOTOR and N(on module board) is less than DC 10V before start servicing. DEFROST TEMP.SENSOR AMBIENT TEMP.SENSOR SUCTION TEMP.SENSOR COMPRESSOR DISCHARGE TEMP.SENSOR CN21 CN20 OUTDOOR WIRING DIAGRAM CN19 CN18 CN25 CN3 CN23 CN24 CN4 CN15 CAPACITOR CN13 CN14 MODULE BOARD CN5CN6 AC-NAC-L T25A/250VAC CN29 FUSE1 SOCKET PROTECT AC- N CN9 CN8 AC-L L0(CN6) W LI (CN7) W CN10 CN11 TERMINAL BLOCK PFC REACTOR POWER to double-way air exchange motor UNIT IN D O O R TO to single-way air exchange motor Remark thedottedpartsare optional for different unit. ELECTRIC EXPANSION VALVE AC FAN MOTOR 4-WAY VALVE B BLACK OR ORANGE W WHITE BR BROWN R RED Y/G YELLOW/GREEN BL BLUE 14

FUSE1 HSU-09/12/18/24HEA03/R2(DB)-I Wring Diagramme HSU-18HEA03/R2(DB)-I Indoor unit INDOOR UNIT WIRING DIAGRAM RECEIVER DISPLAY EMERGENCY SWITCH TEMP.SENSOR AMBIENT TEMP.SENSOR PIPING LOUVER MOTOR CN6 CN8 CN9 ION GENERATOR CN601 Y/G R W CN1 CON2 CON1 CON3 B CN3 CON605 CON5 CON606 CON607 FUSE T3.15A/250V AC R R B R B CON001 CON002 CON003 CON004 CON005 CN001 R Y/G CN4 W Y/G TO OUTDOOR UNIT B BLACK R RED W WHITE Y/G YELLOW/GREEN BL BLUE Outdoor unit WARNING CAUTION DON'T TOUCH CAPACITOR, EVEN AFTER PLUG-OFF ( DANGER OF ELECTRIC SHOCK) The capacitor retains high voltage even after the plug-off. For your safety, be sure to wait at least 5 minutes. after plug off and use a tester to confirm the voltage between connector P and N is less than DC 10V before start servicing. DEFROST TEMP.SENSOR AMBIENT TEMP.SENSOR SUCTION.TEMP.SENSOR COMP.TEMP.SENSOR NOTES: THE DOTTED PARTS ARE OPTIONAL OUTDOOR UNIT WIRING DIAGRAM CN21 CN20 CN19 CN18 CN25 CN15 DC FAN MOTOR CN22 CN11 COMPRESSOR R W B OUTDOOR PCB SOCKET CN29 PROTECT CN1 CN3 CN2 CAP BOARD CN4 BL OR Y/G CN23 CN24 CN4 CN3 CN13 CN14 CN9 CN6 ELECTRIC AC FAN MOTOR EXPANSION VALVE 4-WAY VALVE W V U CN11 CN10 CN5 T2 5A/ 250VAC OR BL CN2 CN1 0010518045 LI MODULE BOARD (CN3) W AC-L(CN1) AC-N(CN2) LO(CN4) W P N W R B W TE RMINA L BL OK C Y/G Y/G Double-way air exchange MOTOR Single-way air exchange MOTOR R B W REACTOR TO INDOOR UNIT PO WE R BLACK RED OR ORANGE BL BLUE WHITE Y/ ELLOW /GREEN 15

FLITER HSU-09/12/18/24HEA03/R2(DB)-I Wring Diagramme HSU-24HEA03/R2(DB)-I Indoor unit INDOOR UNIT DIAGRAM 0010514862 ANION GENERATOR Y/G FAN MOTOR EMERGENCY SWITCH BRUSH LEFT STEP MOTOR RIGHT STEP MOTOR AMBIENT TEMP.SENSOR PIPING TEMP.SENSOR CN2 CN11 CN7 CN6 CN10 C0N7 C0N6 C0N4 C0N5 CON3 CN5 CN8 UP STEP MOTOR 120 T3.15A/250VAC FUSE1 CON1(CON8) CON2 CN3 INTEGRATED CONTROLLER DOWN STEP MOTOR CN12 DISPLAY RECEIVER BOARD TO OUTDOOR DC MOTOR 1 2 3 BR BL UV LAMP Outdoor unit TO OUTDOOR UNIT POWER SUPPLY NOTES: THE PARTS OF DOTTED ARE OPTIONAL 80 W: WHITE B: BLACK R: RED BL: BLUE BR: BROWN Y/G: YELLOW /GREEN WARNING CAUTION DON'T TOUCH CAPACITOR, EVEN AFTER PLUG-OFF ( DANGER OF ELECTRIC SHOCK) The capacitor retains high voltage even after the plug-off. For your safety, be sure to wait at least 5 minutes. after plug off and use a tester to confirm the voltage between connector P and N is less than DC 10V before start servicing. OUTDOOR UNIT WIRING DIAGRAM COMPRESSOR CN11 CN10 MODULE BOARD CAP BOARD 0010562188 LI (CN3) AC-L (CN1) AC-N (CN2) P512 LO (CN4) W W FUSE T25A/250VAC REACTOR TERMINAL BLOCK POWER SUPPLY DEFROST TEMP.SENSOR AMBIENT TEMP.SENSOR SUCTION.TEMP.SENSOR COMP.TEMP.SENSOR NOTES: THE PARTS OF DOTTED ARE OPTIONAL OUTDOOR PCB ELECTRIC EXPANSION VALVE DC FAN MOTOR AC FAN MOTOR 4-WAY VALVE R Double-way air exchange MOTOR Single-way air exchange MOTOR TO INDOOR B BLACK R RED OR ORANGE BL BLUE W WHITE Y/G YELLOW /GREEN 16

Capacity 9 Performance Curves Diagram 9.1 cooling capacity-temp. curves HSU-09HEA03/R2(DB)-I performance curves cooling value-temerature talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 1686 1697 1707 1486 1496 1539 1389 1173 18/14 2169 2180 2247 1995 1958 1828 1716 1530 20/15 2651 2664 2677 2582 2420 2259 2123 1887 22/16 2597 2613 2630 2562 2387 2181 2042 1877 25/18 2544 2563 2582 2541 2354 2168 2045 1849 27/19 2805 2715 2765 2602 2500 2349 2226 2002 30/22 3082 2934 3122 2828 2698 2568 2396 2249 32/23 3182 2918 3128 2799 2742 2633 2505 2277 32/24 3261 2992 3206 2871 2813 2701 2570 2340 3500 3000 2500 2000 1500 1000 18/ 12 18/ 14 20/ 15 22/ 16 25/ 18 27/ 19 30/ 22 32/ 23 32/ 24 18 C 20 C 25 C 32 C 35 C 40 C 43 C 46 C 17

Capacity HSU- 12HEA03/R2(DB)-Iperformance curves cooling value-temerature talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 2686 2697 2707 2486 2496 2539 2389 2173 18/14 3169 3180 3247 2995 2958 2828 2716 2530 20/15 3651 3664 3677 3582 3420 3259 3123 2887 22/16 3597 3613 3630 3562 3387 3181 3042 2877 25/18 3544 3563 3582 3541 3354 3168 3045 2849 27/19 3805 3715 3765 3602 3500 3349 3226 3002 30/22 4082 3934 4122 3828 3698 3568 3396 3249 32/23 4182 3918 4128 3799 3742 3633 3505 3277 32/24 4261 3992 4206 3871 3813 3701 3570 3340 4500 4000 3500 3000 2500 2000 1500 1000 18/ 12 18/ 14 20/ 15 22/ 16 25/ 18 27/ 19 30/ 22 32/ 23 32/ 24 18 C 20 C 25 C 32 C 35 C 40 C 43 C 46 C 18

Capacity HSU-18HEA03/R2(DB)-I performance curves cooling capacity and indoor/outdoor temp. talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 4793 4598 4554 4493 4498 4519 4245 4152 18/14 5033 4840 4823 4748 4729 4664 4408 4198 20/15 5275 5082 5039 5041 4960 4879 4611 4215 22/16 5249 5057 5015 5031 4945 4841 4571 4250 25/18 5222 5031 4991 5021 4927 4834 4572 4310 27/19 5352 5107 5082 5051 5000 4925 4663 4480 30/22 5491 5276 5261 5164 5099 5034 4748 4510 32/23 5545 5298 5264 5150 5121 5067 4802 4555 32/24 5581 5360 5303 5185 5156 5101 4835 4600 cooling value-temp. curves 6000 cooling capacity 5500 5000 4500 18 C 20 C 25 C 32 C 40 C 43 C 46 C 4000 18/12 18/14 20/15 22/16 25/18 27/19 30/22 32/23 32/24 indoor temp. 19

Capacity HSU-22HEA03/R2(DB)-I performance curves cooling capacity and indoor/outdoor temp. talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 5693 5498 5454 5393 5398 5419 5145 5052 18/14 5933 5740 5723 5648 5629 5564 5308 5098 20/15 6175 5982 5939 5941 5860 5779 5511 5115 22/16 6149 5957 5915 5931 5845 5741 5471 5150 25/18 6122 5931 5891 5921 5827 5734 5472 5210 27/19 6252 6007 5982 5951 5900 5825 5563 5380 30/22 6391 6176 6161 6064 5999 5934 5648 5410 32/23 6445 6198 6164 6050 6021 5967 5702 5455 32/24 6481 6260 6203 6085 6056 6001 5735 5500 cooling value-temp. curves 7000 6500 cooling capacity 6000 5500 5000 18 C 20 C 25 C 32 C 40 C 43 C 46 C 4500 4000 18/12 18/14 20/15 22/16 25/18 27/19 30/22 32/23 32/24 indoor temp. 20

Capacity 9.2 heating capacity-temp.curves HSU- 09HEA03/R2(DB)-I performance curves heating capacity and indoor/outdoor temp.curves outdoor temp. DB/WB 15 indoor temp.(humidity 46%) 20 25-15 645 572 475-5 1484 1398 1275 5 1886 1794 1669 7/6 2399 2800 1928 15 2900 2950 2700 20 3200 3100 3000 25 3700 3450 3200 heating capacity and indoor/outdoor temp. cu rves 15 C 20 C 25 C 3700 3200 conoling capacity(w) 2700 2200 1700 1200 700 200 1 2 3 4 5 6 7 indoor tempe. (DB/ WB) 21

Capacity HSU-12HEA03/R2(SDB)-I performance curves heating capacity and indoor/outdoor temp.curves outdoor temp. DB/ WB 15 indoor temp.(humidity 46%) 20 25-15 1645 1572 1475-5 2484 2398 2275 5 2886 2794 2669 7/6 3399 3800 2928 15 3900 3950 3700 20 4200 4100 4000 25 4700 4450 4200 heati ng capacity and indoor / out door temp. cur ves 15 C 20 C 25 C 5000 4500 4000 conoling capacity(w) 3500 3000 2500 2000 1500 1000 1 2 3 4 5 6 7 indoor tempe.( DB/WB) 22

Capacity HSU-18HEA03/R2(DB)-I performance curves heating capacity and indoor/outdoor temp.curves outdoor temp. DB/WB 15 indoor temp.(humidity 46%) 20 25-15 3245 3172 3075-5 4084 3998 3875 5 4486 4394 4269 7/6 4999 5400 4528 15 5500 5550 5300 20 5800 5700 5600 25 6300 6050 5800 heating capacity and inddor/outdoor temp. curves 6500 6000 heating capacity 5500 5000 4500 4000 3500 15 20 25 3000 2500-15 -5 5 7/6 15 20 25 outdoor temp 23

Capacity HSU-22HEA03/R2(DB) performance curves heating capacity and indoor/outdoor temp.curves outdoor temp. DB/WB 15 indoor temp.(humidity 46%) 20 25-15 4252 4179 4082-5 5091 5005 4882 5 5493 5401 5276 7/6 6006 6407 5535 15 6507 6557 6307 20 6807 6707 6607 25 7307 7057 6807 heating capacity and inddor/outdoor temp. curves 8500 7500 heating capacity 6500 5500 4500 3500 15 20 25 2500-15 -5 5 7/6 15 20 25 outdoor temp 24

Capacity 9.3 Cooling power consumption-temp.curves HSU-09HEA03/R2(DB)-Iperformance curves power consumption value-teme.talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 368 376 391 488 615 835 891 946 18/14 442 450 467 574 714 956 1017 1078 20/15 543 522 510 711 742 877 954 1032 22/16 546 524 511 727 750 878 957 1037 25/18 548 526 512 742 758 879 960 1041 27/19 566 543 530 765 780 904 987 1070 30/22 585 562 548 787 803 929 1014 1099 32/23 591 554 527 746 782 927 1024 1121 32/24 610 564 536 757 794 940 1038 1136 power consumption- temp.curves 1100 power consumption(w) 900 700 500 300 18 20 25 32 35 40 43 46 100 18/ 12 18/ 14 20/ 15 22/ 16 25/ 18 27/ 19 30/ 22 32/ 23 32/ 24 i ndoor tempe. (DB/ WB) 21 25

Capacity HSU-12HEA03/R2(DB)-I performance curves power consumption value-teme.talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 668 676 691 788 915 1135 1191 1246 18/14 742 750 767 874 1014 1256 1317 1378 20/15 843 822 810 1011 1042 1177 1254 1332 22/16 846 824 811 1027 1050 1178 1257 1337 25/18 848 826 812 1042 1058 1179 1260 1341 27/19 866 843 830 1065 1080 1204 1287 1370 30/22 885 862 848 1087 1103 1229 1314 1399 32/23 891 854 827 1046 1082 1227 1324 1421 32/24 910 864 836 1057 1094 1240 1338 1436 1500 power consumption-temp.curves power consumption(w) 1400 1300 1200 1100 1000 900 800 700 600 18 20 25 32 35 40 43 46 500 18/ 12 18/ 14 20/ 15 22/ 16 25/ 18 27/ 19 30/ 22 32/ 23 32/ 24 i ndoor t empe. ( DB/ WB) 26

Capacity HSU-18HEA03/R2(DB)-I performance curves power consumption value-teme.talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 1268 1321 1391 1528 1592 1737 1785 1719 18/14 1273 1326 1396 1534 1598 1746 1795 1729 20/15 1297 1351 1422 1563 1628 1780 1831 1763 22/16 1317 1372 1444 1587 1653 1804 1854 1785 25/18 1337 1393 1466 1611 1678 1830 1880 1810 27/19 1355 1411 1485 1632 1700 1855 1907 1836 30/22 1382 1440 1516 1666 1735 1884 1934 1862 32/23 1406 1465 1542 1695 1765 1941 2000 1926 32/24 1411 1482 1555 1713 1785 1955 2012 1938 power consumption-temp. curves 2200 power consumption 2000 1800 1600 1400 1200 18 20 25 32 35 40 43 46 1000 18/12 18/14 20/15 22/16 25/18 27/19 30/22 32/23 32/24 indoor temp 27

Capacity HSU-24HEA03/R2(DB)-I performance curves power consumption value-teme.talbe indoor temp. outdoor temp.(humidity 46%) DB/WB 18 20 25 32 35 40 43 46 18/12 1568 1621 1691 1828 1892 2037 2085 2019 18/14 1573 1626 1696 1834 1898 2046 2095 2029 20/15 1597 1651 1722 1863 1928 2080 2131 2063 22/16 1617 1672 1744 1887 1953 2104 2154 2085 25/18 1637 1693 1766 1911 1978 2130 2180 2110 27/19 1655 1711 1785 1932 2000 2155 2207 2136 30/22 1682 1740 1816 1966 2035 2184 2234 2162 32/23 1706 1765 1842 1995 2065 2241 2300 2226 32/24 1711 1782 1855 2013 2085 2255 2312 2238 power consumption-temp. curves 2500 2400 power consumption 2300 2200 2100 2000 1900 1800 1700 18 20 25 32 35 40 43 46 1600 1500 18/12 18/14 20/15 22/16 25/18 27/19 30/22 32/23 32/24 indoor temp 28

Capacity 9.4 heating power consumption-temp.curves HSU-09HEA03/R2(DB)-Iperformance curves power consumption value-temp.talbe outdoor temp. DB/WB 15 indoor temp.(humidity 46%) 20 25-15 432 487 555-5 515 648 715 5 525 630 731 7/6 743 780 808 15 627 725 741 20 392 499 601 25 314 392 489 heat ing capaci t y and indoor / outdoor temp. cur ves 15 20 25 1000 900 conoling capacity(w) 800 700 600 500 400 300-15 -5 5 7/ 6 15 20 25 i ndoor tempe. ( DB/ WB) 29

Capacity HSU-12HEA03/R2(DB)-I performance curves power consumption value-temp.talbe outdoor temp. DB/WB 15 indoor temp.(humidity 46%) 20 25-15 732 787 855-5 815 948 1015 5 825 930 1031 7/6 1043 1080 1108 15 927 1025 1041 20 692 799 901 25 614 692 789 heat i ng capaci t y and i ndoor / out door t emp. cur ves 15 20 25 1200 1100 conoling capacity(w) 1000 900 800 700 600-15 -5 5 7/ 6 15 20 25 i ndoor tempe. (DB/WB) 30

Capacity HSU-18HEA03/R2(DB)-I performance curves power consumption value-temp.talbe outdoor temp. DB/WB 15 indoor temp.(humidity 46%) 20 25-15 1562 1650 1722-5 1664 1750 1820 2 /1 2011 2100 2169 7/6 1639 1730 1793 15 1420 1505 1574 20 1377 1460 1532 25 1313 1400 1465 power consumption value-temp.table 2500 power consumption 2000 1500 1000 500 15 20 25 0-15 -5 2 /1 7/6 15 20 25 outdoor temp. 31

Capacity HSU-24HEA03/R2(DB)-I performance curves power consumption value-temp.talbe outdoor temp. DB/WB 15 indoor temp.(humidity 46%) 20 25-15 1862 1950 2022-5 1964 2050 2120 2 /1 2311 2400 2469 7/6 1939 2030 2093 15 1720 1805 1874 20 1677 1760 1832 25 1613 1700 1765 power consumption value-temp.table 3000 power consumption 2500 2000 1500 1000 500 15 20 25 0-15 -5 2 /1 7/6 15 20 25 outdoor temp. 32

9.5 Cooling discharge pressure HSU-09/12/18/24HEA03/R2(DB)-I Capacity HSU-09HEA03/R2(DB)-I performance curves COOLING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 2053 2255 2336 25 2078 2210 2321 30 2451 2623 2694 35 2764 2890 2971 40 3075 3156 3247 45 3429 3600 3641 4000 COOLING DISCHARGE PRESSURE 16 19 22 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 15 25 30 35 40 45 Outdoor Temp 33

Capacity HSU-12HEA03/R2(DB)-I performance curves COOLING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 2020 2220 2300 25 2040 2170 2230 30 2410 2580 2650 35 2715 2840 2920 40 3020 3100 3190 45 3370 3540 3580 4000 COOLING DISCHARGE PRESSURE 16 19 22 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 15 25 30 35 40 45 Outdoor Temp 34

Capacity HSU-18HEA03/R2(DB)-I performance curves COOLING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 2153 2355 2436 25 2178 2310 2421 30 2551 2723 2794 35 2864 2990 3071 40 3175 3256 3347 45 3529 3700 3741 4000 COOLING DISCHARGE PRESSURE 16 19 22 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 15 25 30 35 40 45 Outdoor Temp 35

Capacity HSU-24HEA03/R2(DB)-I performance curves COOLING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 2173 2375 2456 25 2198 2330 2441 30 2571 2743 2814 35 2884 3010 3091 40 3195 3276 3367 45 3549 3720 3761 4000 COOLING DISCHARGE PRESSURE 16 19 22 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 15 25 30 35 40 45 Outdoor Temp 36

Capacity 9.6 cooling suction pressure curves HSU-09HEA03/R2(DB)-I performance curves COOLING SUCTION PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 664 752 764 25 693 772 776 30 696 777 775 35 706 780 796 40 744 822 838 45 772 854 869 1000 COOLING SUCTION PRESSURE 16 19 22 DISCHARGE PRESSURE 900 800 700 600 500 400 15 25 30 35 40 45 Outdoor Temp 37

Capacity HSU-12HEA03/R2(DB)-I performance curves COOLING SUCTION PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 620 693 720 25 648 712 731 30 650 717 730 35 660 720 750 40 696 760 790 45 723 790 820 1000 COOLING SUCTION PRESSURE 16 19 22 DISCHARGE PRESSURE 900 800 700 600 500 400 15 25 30 35 40 45 Outdoor Temp 38

Capacity HSU-18HEA03/R2(DB)-I performance curves COOLING SUCTION PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 684 772 784 25 713 792 796 30 716 797 795 35 726 800 816 40 764 842 858 45 792 874 889 cooling sunction pressure table cooling sunction pressure 1000 900 800 700 600 500 400 300 200 100 0 15 25 30 35 40 45 outdoor temp. 16 19 22 39

Capacity HSU-24HEA03/R2(DB) performance curves COOLING SUCTION PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 16 indoor temp. 19 22 15 699 787 799 25 728 807 811 30 731 812 810 35 741 815 831 40 779 857 873 45 807 889 904 cooling sunction pressure table cooling sunction pressure 1000 900 800 700 600 500 400 300 200 100 0 15 25 30 35 40 45 outdoor temp. 16 19 22 40

Capacity 9.7 heating discharge pressure curves HSU-09HEA03/R2(DB)-Iperformance curves HEATING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 15 indoor temp. 20 25 15 2106 2274 2439 10 2172 2363 2585 5 2427 2543 2752 0 2393 2563 2764 5 2552 2733 2858 10 2920 3065 3370 15 3419 3602 3670 20 3060 3433 3603 4000 HEATING DISCHARGE PRESSURE 15 20 25 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 1000 15 10 5 0 5 10 15 20 Outdoor Temp 41

Capacity HSU-12HEA03/R2(DB)-I performance curves HEATING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 15 indoor temp. 20 25 15 1690 1910 2160 10 1855 2080 2335 5 2020 2250 2510 0 2045 2385 2630 5 2200 2520 2750 10 2590 2940 3030 15 3110 3360 3430 20 2840 3160 3370 4000 HEATING DISCHARGE PRESSURE 15 20 25 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 1000 15 10 5 0 5 10 15 20 Outdoor Temp 42

Capacity HSU-18HEA03/R2(DB)-I performance curves HEATING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 15 indoor temp. 20 25 15 2036 2204 2369 10 2102 2293 2515 5 2357 2473 2682 0 2323 2493 2694 5 2482 2663 2788 10 2850 2995 3300 15 3349 3532 3600 20 2990 3363 3533 4000 HEATING DISCHARGE PRESSURE 15 20 25 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 1000 15 10 5 0 5 10 15 20 Outdoor Temp 43

Capacity HSU-24HEA03/R2(DB) performance curves HEATING DISCHARGE PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 15 indoor temp. 20 25 15 2036 2204 2369 10 2102 2293 2515 5 2357 2473 2682 0 2323 2493 2694 5 2482 2663 2788 10 2850 2995 3300 15 3349 3532 3600 20 2990 3363 3533 4000 HEATING DISCHARGE PRESSURE 15 20 25 DISCHARGE PRESSURE 3500 3000 2500 2000 1500 1000 15 10 5 0 5 10 15 20 Outdoor Temp 44

Capacity 9.8 heating suction pressure curves HSU-09HEA03/R2(DB)-I performance curves HEATING SUCTION PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 15 indoor temp. 20 25 15 260 259 262 10 325 330 340 5 394 415 420 0 430 470 478 5 470 540 545 10 600 648 682 15 757 757 818 20 719 749 762 DISCHARGE PRESSURE 1000 900 800 700 600 500 400 300 200 100 0 HEATING SUCTION PRESSURE 15 10 5 0 5 10 15 20 Outdoor Temp 15 20 25 45

Capacity HSU-12HEA03/R2(DB)-Iperformance curves HEATING SUCTION PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 15 indoor temp. 20 25 15 210 210 220 10 280 285 295 5 350 360 370 0 385 430 435 5 420 500 500 10 565 605 640 15 710 710 780 20 680 720 753 DISCHARGE PRESSURE 1000 900 800 700 600 500 400 300 200 100 0 HEATING SUCTION PRESSURE 15 10 5 0 5 10 15 20 Outdoor Temp 15 20 25 46

Capacity HSU-18HEA03/R2(DB)-I performance curves HEATING SUCTION PRESSURE.talbe outdoor temp. (humidity 46%) DB/WB 15 indoor temp. 20 25 15 240 239 242 10 305 310 320 5 374 395 400 0 410 450 458 5 450 520 525 10 580 628 662 15 737 737 798 20 699 729 742 DISCHARGE PRESSURE 1000 900 800 700 600 500 400 300 200 100 0 HEATING SUCTION PRESSURE 15 20 25 15 10 5 0 5 10 15 20 Outdoor Temp 47

10 Sound level HSU-09/12/18/24HEA03/R2(DB)-I Sound presure level Sound level Model 230V,50Hz Cooling/heating H L SL Measuring location Location of microphone sound power level (cooling/heating) HSU-09HEA03/R2(DB)-I 39 34 30 50 cooling 53 106 212 425 850 1700 3400 6800 heating 53 106 212 425 850 1700 3400 6800 80 80 70 NC-70 70 NC-70 60 NC-60 60 NC-60 50 NC-50 50 NC-50 40 NC-40 40 NC-40 30 NC-30 30 NC-30 20 approximate threshold hearing for continuous noise NC-20 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 20 approximate threshold hearing for continuous noise NC-20 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 48

Sound level Sound presure level Model 230V,50Hz Cooling/heating H L SL Measuring location Location of microphone sound power level (cooling/heating) HSU-12HEA03/R2(DB)-I 41 38 36 52 cooling 53 106 212 425 850 1700 3400 6800 heating 53 106 212 425 850 1700 3400 6800 80 80 70 NC-70 70 NC-70 60 NC-60 60 NC-60 50 NC-50 50 NC-50 40 NC-40 40 NC-40 30 NC-30 30 NC-30 20 approximate threshold hearing for continuous noise NC-20 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 20 approximate threshold hearing for continuous noise NC-20 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 49

Sound level Sound presure level Model 230V,50Hz Cooling/heating Measuring location Location of microphone sound power level (cooling/heating) H L SL HSU-18HEA03/R2(DB)-I 44 41 38 52 cooling 53 106 212 425 850 1700 340 0 6800 heating 53 106 212 425 850 1700 340 0 6800 80 80 70 NC-70 70 NC-70 60 NC-60 60 NC-60 50 NC-50 50 NC-50 40 NC-40 40 NC-40 30 NC-30 30 NC-30 20 approximate threshold hearing for continuous noise NC-20 20 approximate threshold hearing for continuous noise NC-20 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 50

Sound level Sound presure level Model 230V,50Hz Cooling/heating Measuring location Location of microphone sound power level (cooling/heating) H L SL HSU-24HEA03/R2(DB) 47/47 45/45 40/40 61/61 heating cooling 53 106 212 425 850 1700 3400 6800 heating 53 106 212 425 850 1700 3400 6800 80 80 70 NC-70 70 NC-70 60 NC-60 60 NC-60 50 NC-50 50 NC-50 40 NC-40 40 NC-40 30 NC-30 30 NC-30 20 approximate threshold hearing for continuous noise NC-20 20 approximate threshold hearing for continuous noise NC-20 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 63 125 250 500 1000 2000 4000 8000 Octave band center frequency(hz) 51

/24 52

12 Control systems For HSU-09,12,18HEA03/R2(DB)-I HSU-09/12/18/24HEA03/R2(DB)-I Control systems 19 31 16 16 15 16 21 10. TIMER ON display 11. FAN SPEED display LOW MED HI 12. LOCK display 13. SWING UP/DOWN display 14. SLEEP display 15. HEALTH display 16. Operation mode display AUTO 28 Operation mode AUTO COOL DRY HEAT FAN Remote controller Display board 1.RESET When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal. 2.LIGHT button Control the lightening and extinguishing of the indoor LED display board. 3. TIMER button Used to select TIMER ON, TIMER OFF, TIMER ON-OFF. 4. CLOCK button Used to set correct time. 5. SLEEP button Used to select sleep mode. 6. MODE button AUTO COOL DRY FAN HEAT 7. HOUR button Used to set clock and timer setting. 8. HEALTH button Used to set healthy operation. 9. ON/OFF button Used for unit start and stop. 30 17.Singal sending display 18. POWER/SOFT display 19. Left/right air flow display 20. TEMP display Remote controller: to display the TEMP. setting. 21. TIMER OFF display 22. TIMER display 23. TEMP button Used to select your desired temperature. 24. FAN button Used to select fan speed: LOW,MED, HI, AUTO. 25. HEALTH AIRFLOW button Used to set the health airflow mode. 26. SWING UP/DOWN button Used to select up or down air sending direction. 27. SWING LEFT/RIGHT button Used to select left/right air flow. 28. SET button Used to confirm timer and clock settings. 29. POWER/SOFT button Every time the button is pressed,display changes as follows: BLANK POWER SOFT 30. LOCK Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be canceled and lock condition display disappears. 31. Singal receiver hole 32. Ambient temp.display When receiving the remote control signal, display the set temperature and in the rest time the room temperature is displayed and this room temperature is only for reference. NOTE:(1) The following functions and related displays are not available: 53

Control systems For HSU-24HEA03/R2(DB)-I 19 10. ON/OFF button Used for unit start and stop. 11. TIMER ON display 12. FAN SPEED display LOW MED HI AUTO POWER/SOFT 28 13. LOCK display 14. SWING UP/DOWN display 15. SLEEP display 16. HEALTH display 17. Operation mode display 30 Operation mode AUTO COOL DRY FAN Remote controller HEAT 1.CODE Used to select CODE A or B with a press,a or B will be displayed on LCD. Please select A without special explanation. 2.RESET When the remote controller appears abnormal, use a sharp pointed article to press this button to reset the remote controller normal. 3.LIGHT button Control the lightening and extinguishing of the indoor LED display board. 4. TIMER button Used to select TIMER ON, TIMER OFF, TIMER ON-OFF. 5. CLOCK button Used to set correct time. 6. HEALTH button Used to set healthy operation. 7. MODE button AUTO COOL DRY FAN HEAT 8. HOUR button Used to set clock and timer setting. 9. SWING button Used to select up or down air sending direction. 18.Singal sending display 19. POWER/SOFT display 20. Left/right air flow display 21. TEMP display Remote controller: to display the TEMP. setting. 22. TIMER OFF display 23. CLOCK display 24. TEMP button Used to select your desired temperature. 25. FAN button Used to select fan speed: LOW,MED, HI, AUTO. 26. HEALTH AIRFLOW button Used to set the health airflow mode. 27. SLEEP button Used to select sleep mode. 28. SET button Used to confirm timer and clock settings. 29. POWER/SOFT button Use to set power/soft function. 30. LOCK Used to lock buttons and LCD display. If pressed, the other buttons will be disabled and the lock condition display appears. Press it once again, lock will be cancelled and lock condition display disappears. NOTE: The following functions and related displays are not available: 20 26 54

13 Center of gravity HSU-09/12/18/24HEA03/R2(DB)-I HSU-09HEA03/R2(DB)-I Indoor unit Center of gravity 480 170 265 182 795 Outdoor unit 55

Center of gravity HSU-12HEA03/R2(DB)-I Indoor unit 547 153 265 182 938 Outdoor unit 56

Center of gravity HSU-18HEA03/R2(DB)-I Indoor unit 547 153 265 182 938 Outdoor unit 820 145 310 682 342 273 57

Center of gravity HSU-24HEA03/R2(DB)-I 860 110 140 320 1140 240 952 350 840 513 590 165 58

5

HSU09/12/18HEA03/R2(DB)-I Installation Outdoor Model 09/12K 18K 24K Max.allowable length 15m 25m 25m Max.allowable height 10m 15m 15m Additional refrigerant required for refrigerant pipe exceeding 7m in length 20g/m 20g/m 50g/m Arrangement of piping directions Gas pipe Liquid pipe O.D. 6.35 O.D. 9.52 O.D. 6.35 O.D. 12.7 O.D. 9.52 O.D.15.88 Left Rear left Rear right *Be sure to add the proper amount of additional refrigerant. Failure to do so may result in reduced performance. Below Right Wrap the installation pipe with the finishing tape from bottom to top Model 25 / 35 class or tmh e ore than m 10cm n 10cm a Service lid How to remove the service lid. This service lid is an open/close type. Slide the lid downward to remove it. How to attach the service lid. Insert the upper part of the service lid into the outdoor unit to install. Tighten the screws. Where there is a danger of the unit falling, use foot bolts, or wires. 319.5 50 38 115 580 115 184 580 184 9K 12K 18K 24K Fix the unit to concrete or block with bolts( 10mm) and nuts irmly and horizontall When fitting the unit to wall surface, roof or rooftop, fix as upporter surely with nails or wires in consideration of earthquake and strong wind. The distance between the indoor unit and the floor should be no more than 2m If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

The end Sincere Forever Haier Group Chen Huimin Fan Shuangyuan Sun Qiang Yang Bifei 60 W Hongjin