Measurement of Soil Suction In Situ Using the Fredlund Thermal Conductivity Sensor *

Similar documents
Identification of key parameters on Soil Water Characteristic Curve

A new test procedure to measure the soil-water characteristic curves using a small-scale centrifuge

EFFECT OF COMPACTION ON THE UNSATURATED SHEAR STRENGTH OF A COMPACTED TILL

A Study on Suction-rainfall Response of a Cut Slope in Unsaturated Residual Soil Using a Field Rain Simulator

Effect of characteristics of unsaturated soils on the stability of slopes subject to rainfall

Soil-Suction Measurements Using the Filter Paper Method to Evaluate Swelling Potential

A Method for Predicting the Matric Suction of Unsaturated Soils with Soil Color Recognition

EFFECT OF RELICT JOINTS IN RAIN INDUCED SLOPE FAILURES IN RESIDUAL SOIL

Unsaturated Shear Strength Behavior under Unconsolidated Undrained Tests

THE ULTIMATE SKIN RESISTANCE OF CONCRETE PILE IN PARTIALLY SATURATED COHESIVE SOIL BY MODIFIED Β METHOD

Loading unsaturated soil. *Mohamed Abdellatif Ali Albarqawy 1)

LABORATORY STUDY ON THE CONSOLIDATION SETTLEMENT OF CLAY-FILLED GEOTEXTILE TUBE AND BAGS

04.SOIL MOISTURE MEASUREMENT

Analysis of Pullout Resistance of Soil-Nailing in Lateritic Soil

Durham Research Online

Soil-Structure Interaction of a Piled Raft Foundation in Clay a 3D Numerical Study

Transition of soil strength during suction pile retrieval

A DETAILED ANALYSIS OF SLOPE STABILITY USING FINITE ELEMENT METHOD (FEM)

THE ROLE OF SUCTION IN THE PERFORMANCE OF CLAY FILL RONALD F. REED, P.E. 1 KUNDAN K. PANDEY, P.E. 2

Advanced Foundation Engineering. Soil Exploration

Laboratory Tests to Determine Shear Strength of Soils

EXPLORING POSSIBILITIES WITH THE DEVELOPMENT OF THE LOOP HEAT PIPE TECHNOLOGY. Roger R. Riehl

The City of Winnipeg Bid Opportunity No GEOTECHNICAL REPORT - TEST HOLE LOGS

Soil-atmosphere interaction in unsaturated cut slopes

Measurement of the Shear Strength of an Expansive Soil by Combining a Filter Paper Method and Direct Shear Tests

Capillary barrier dissipation by new wicking geotextile

MEASURING A WORLD OF DIFFERENT SOILS SOIL WATER RETENTION CURVES

SUMMARY AND CONCLUSION

Movement of soil water- Infiltration, percolation, permeability Drainage -

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Transmissivity of a Nonwoven Polypropylene Geotextile Under Suction

Research & Reviews in. Analytical measurement and instrumentation for agriculture engineering

What s The Difference Between Soil Moisture and Plant-Available Water?

Saturated and unsaturated stability analysis of slope subjected to rainfall infiltration

Analysis of Embankments with Different Fill Materials using Plaxis-2D

Shear Strength of Soils

EFFECT OF CENTRAL PILE IN INCREASING THE BEARING CAPACITY OF BORED PILE GROUPS

Advanced Foundation Engineering. Introduction

Numerical Analysis of the Bearing Capacity of Strip Footing Adjacent to Slope

EFFECT OF MATRIC SUCTION CHANGES ON UNSATURATED SOIL PARAMETER IN SLOPE STABILITY ANALYSIS DUE TO RAINFALL. Ahmad RIFA I 1

Keywords: Unsaturated flow, infiltration, marginal fill, rainfall, nonwoven geotextile, sand cushion 1 INTRODUCTION

Strength Parameter Selection in Stability Analysis of Residual Soil Nailed Walls

EAT 212 SOIL MECHANICS

Proposed ASTM Standard Method

A Cost Effective Multi-Spectral Scanner for Natural Gas Detection

Slope Stability of Soft Clay Embankment for Flood Protection

Evaluation of the Development of Capillary Barriers at the Interface between Fine-grained Soils and Nonwoven Geotextiles

Cracking in Liner Behavior and Desiccation of Compacted Landfill Liner Soils

Reinforcement with Geosynthetics

RESPONSE OF ANCHOR IN TWO-PHASE MATERIAL UNDER UPLIFT

OVEN INDUSTRIES, INC.

EFFECT OF BOLT CONNECTION OF SQUARE-SHAPED GEOCELL MODEL ON PULLOUT TEST RESULTS

Table III.A PHYSICAL PROPERTIES OF CLAYEY SOIL

The Experimental Research on Grain Storage Heat and Moisture Transfer Siyu Chen 1,2, Wenfu Wu 1,Yan Xu 1,Chunshan Liu 2, Yaqiu Zhang 1, a

Compaction. Compaction purposes and processes. Compaction as a construction process

B & W Engineering Laboratories, Inc. P.O. Box Memphis, Tennessee (901)

Keywords: slope stability, numerical analysis, rainfall, infiltration. Yu. Ando 1, Kentaro. Suda 2, Shinji. Konishi 3 and Hirokazu.

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

A Study on Stabilization of Subgrade Soil Using Natural Fibers (Coir and Jute)

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Prof. B V S Viswanadham, Department of Civil Engineering, IIT Bombay

Shear strength features of unsaturated clayey sand by lab test

Available online at ScienceDirect. Procedia Engineering 125 (2015 )

Click Here To View Item at

Monitoring Soil Moisture

SHEAR STRENGTH BEHAVIOR OF AN UNSATURATED SILTY SOIL IN LOW AND HIGH SUCTION RANGE UNDER CONSTANT VOLUME CONDITONS

[Gupta* et al., 5(7): July, 2016] ISSN: IC Value: 3.00 Impact Factor: 4.116

Some Modeling Improvements for Unitary Air Conditioners and Heat Pumps at Off-Design Conditions

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

A comparison of numerical algorithms in the analysis of pile reinforced slopes

COMPARISON OF SHEAR STRENGTH PARAMETERS OF BLACK COTTON SOIL WITH EFFECT OF RELATIVE COMPACTION

Computer Modelling and Simulation of a Smart Water Heater

FTW04. Application. Types Available. Security Advice Caution. Surface mounting room sensor for relative humidity and temperature.

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

ACCURATE ELECTRONICS INC

Swelling Treatment By Using Sand for Tamia Swelling Soil

Study on Methods of Drying on Soils

Modified geotextile tube a new geotextile tube for optimized retaining efficiency and dewatering rate

Technical Report Documentation Page 2. Government 3. Recipient s Catalog No.

Datasheet: K-22 LO Sensor

EasyLog Data Logger Series

Research on the Monitor and Control System of Granary Temperature and Humidity Based on ARM

AUTHOR(S) Jan Ove Busklein CLIENT(S) Nittedal Torvindustri AS CLASS. THIS PAGE ISBN PROJECT NO. NO. OF PAGES/APPENDICES. Restricted 3C /1

Temperature Data Logging

Automatic Isokinetic Sampler ST5

GEOMEMBRANE FIELD INSTALLATION

EasyLog Data Logger Series

Numerical study of heat pipe application in heat recovery systems

Stability analysis of slopes with surcharge by LEM and FEM

DRAFT ONONDAGA LAKE CAPPING AND DREDGE AREA AND DEPTH INITIAL DESIGN SUBMITTAL H.3 STATIC SLOPE STABILITY ANALYSES

QUALITY ASSURANCE AND SAFETY AT A TID RADIATION TEST LABORATORY

Combined functioning of geotextile as barrier and drainage material in unsaturated. earth retaining structures. Amalesh Jana 1 and Arindam Dey 2

Groundwater Flow Modeling of ROW Bioswales Adjacent to Residential Buildings

THERMAL PROCESSING THEORY

Experimental tests for geosynthetics anchorage trenches

DIESEL Engine Fire Pump Controllers Features

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

Soil characteristics that influence nitrogen and water management

Frequently asked questions: Intelligent Transmitter Series

Control of temperature and humidity surrounding the stone chamber of Takamatsuzuka tumulus during its dismantlement

Transcription:

Measurement of Soil Suction In Situ Using the Fredlund Thermal Conductivity Sensor * Y.Y. Perera, Ph.D., P.E. and J.M. Padilla, Ph.D. GCTS, 6103 South Maple Avenue, Tempe, AZ 85283, USA D.G. Fredlund, Ph.D., P.Eng., O.C. Department of Civil and Geological Engineering, University of Saskatchewan, Canada Introduction The measurement of matric suction in the field is a challenging task due to a variety of limitations, laborious procedures, and the cost of currently available methods. The most commonly used methods available for the measurement of soil suction are psychrometers, filter papers, tensiometers, and thermal conductivity sensors. The nulltype pressure plate apparatus, as well as the filter paper method can be used for measuring suction in the laboratory. A list of suction measurement methods, the component of soil suction measured, valid ranges, and constraints associated with these methods are presented in Table 1. The information in Table 1 shows that each method has its own limitations. Psychrometers are insensitive in the low suction ranges, sensitivity deteriorates with time, are sensitive to thermal field, and require frequent maintenance. Filter paper calibrations require considerable time to equilibrate, and filter paper measurements are difficult to automate. Tensiometers function in the low suction range and require daily maintenance. * Copyright 2004 by GCTS, 6103 South Maple Avenue, Tempe, AZ 85283 Presentation material for Mining and Waste Management Short Course, Vail, CO, October 10, 2004.

Table 1. Methods for measuring total and matric suction (Ridley & Wray 1995, Fredlund & Rahardjo 1989). Device Method (Property Measured) Suction Measured Range (kpa) Principal constraints Thermocouple psychrometers Thermistor psychrometers Transistor psychrometers Filter paper (non-contact) Filter paper (in-contact) Pressure plate (Null technique) Standard tensiometer Osmotic tensiometer Imperial College tensiometers Porous block (Gypsum, nylon, fiberglass) Indirect (Relative Humidity) Indirect (Relative Humidity) Indirect (Relative Humidity) Indirect (Water content) Indirect (Water content) Total 100 to 7500 Affected by temperature fluctuations and gradients. Sensitivity deteriorates with time. Total 100 to 10,000 Poor sensitivity in the low suction range. Frequent re-calibration is required. Total 100 to 71,000 Frequent re-calibration is required. Specimens must be tested in order of increasing suction to avoid hysteresis. Total 400 to 30,000 Calibration is sensitive to the equilibration time. Matric Entire range Automation of the procedure is difficult. Direct Matric 0 to 1500 Range of suction limited by the air-entry value of the plate (laboratory usage). Direct Matric 0 to 90 Requires daily maintenance. Temperature fluctuations affect readings. Direct Matric 0 to 1500 Reference pressure can deteriorate with time. Temperature dependent. Direct Matric 0 to 1800 Range in suction is limited by the airentry value of the ceramic. Cavitation problems with time. Indirect (Electrical resistance) Matric 30 to 3000 Observations need to be corrected for temperature. Blocks are subject to hysteresis and changes in calibration due to salt. Response to suction can be slow. Original heat dissipation sensors Fredlund Thermal Conductivity Sensor Indirect (Thermal conductivity) Indirect (Thermal conductivity) Matric 0 to 1,000 + High failure rate. Fragile ceramic. Matric 0 to 1,500 + Range in suction is controlled by the pore-size distribution of the ceramic. The Fredlund thermal conductivity sensor (FTC sensor) holds promise for field applications due to low maintenance, durability, ability to automate the testing, insensitivity to salinity and soil type, and reasonable cost. The FTC sensor was developed by GCTS based on previous models developed by Fredlund and other researchers at the University of Saskatchewan, Canada (Fredlund et al., 2000; Shuai et al., 2000; Marjerison, et al., 2001; Feng et al., 2002; Shuai et al., 2002; GCTS FTC Sensor 2

Feng et al., 2003; Nichol et al., 2003; Shuai et al., 2003; Tan et al., 2003). Considerable attention had been given to the accuracy and durability of the sensor during the development process (Padilla et al., 2004). As the name suggests, the thermal conductivity of the ceramic tip of the sensor forms the basis for measuring the matric suction in a soil. A miniature-heating element embedded in the ceramic tip (Figure 1) is heated by sending a specific quantity of thermal energy to the resistor in the ceramic. The temperature rise in the ceramic is monitored by a temperature sensor located near the heating element. The temperature rise of the sensor is a function of the water content of the ceramic, which, in turn is a function of the matric suction of the soil. 19 mm 65 mm 38 mm 28 mm Figure 1. Cross-section of Fredlund Thermal Conductivity Sensor. GCTS FTC Sensor 3

The main features of this sensor include state-of-the-art digital design, high resolution in temperature measurements, high accuracy in suction measurements, and the ability to use cables more than 100 m in length. Digital signals reduce the cable resistance and temperature effects, which enables the use of longer cables. The FTC sensor records the ambient temperature (i.e. in situ soil temperature) in addition to the primary parameter, the temperature rise. The in situ soil temperature is a very useful piece of information in engineering applications such as performance of highway pavements where both temperature and water content play a significant role in pavement strength. It should be noted that the suction measurements obtained from FTC sensors under freezing conditions are meaningless, but freezing cannot harm the functionality of the sensor. Theoretical Background The thermal conductivity of a porous media increases with increasing water content. Therefore, the measurement of the thermal conductivity of a standard porous block that has come to equilibrium with a soil can be used to measure the water content of the ceramic block. The water content of the ceramic block is dependent on the matric suction of the soil surrounding the ceramic block. Hence, the thermal conductivity of the porous block can be calibrated against the applied matric suction. Several devices had been developed adopting this method since the early 1940s. The materials used for the porous ceramic block over the years have included plaster of paris, gypsum, castone, and a variety of ceramics. Earlier versions of the sensors did not GCTS FTC Sensor 4

perform well in the field due to deterioration of electronics and the porous block with time. As shown in Figure 1, the FTC sensor uses a standardized ceramic block as the porous media and heat is provided to the block by a miniature-heating element. The thermal conductivity of the block is obtained by measuring the temperature rise within the block using a digital temperature sensor. The temperature rise is governed by the heat dissipation, which in turn is dependent upon the thermal conductivity. For example, if the block is wet, more heat will be dissipated during the time the heat pulse is applied, resulting a lower temperature rise than if the block were dry. Sending a constant current for 60 seconds to the ceramics block when the block is completely dry, and doing the same when the ceramic block is saturated, generates two heating curves as shown in Figure 2. The temperature rise corresponding to the dry condition was about 16 o C compared to a temperature rise of about 12 o C corresponding to wet conditions. The calibration curves, which are predetermined in the laboratory form the key information required for matric suction measurements. The calibration curve provides the relationship between the temperature rise of the sensor and the applied matric suction. Once the temperature rise of the sensor is known in the field, the matric suction for the soil can be determined by entering the calibration curve. The section on Sensor Calibration presents more information on this topic. GCTS FTC Sensor 5

40 38 36 Dry Sensor Wet Sensor Temperature ( o C) 34 32 30 28 26 24 22 20 0 10 20 30 40 50 60 70 80 90 100 110 120 Time (seconds) Figure 2. Heating curves showing temperature rises in wet and dry sensors. Summary of Test Procedure for the Field FTC sensors can be used to obtain the field matric suction measurements in unsaturated soil masses or waste piles. Suction measurements better than 5% of the measured suction value are possible with FTC sensors (Padilla et al., 2004). Multiple sensors can be buried at selected locations and connected to a datalogger using electrical cables. The datalogger is programmed to send signals to the sensors at desired time intervals to collect temperature readings and to store the data. Based on the temperature rise at each sensor, a corresponding matric suction value is computed from the calibration curve. The calibration curves are predetermined in the laboratory and provided with the sensors. The sensors can be monitored on a long-term basis and the data reduction can be performed based on weather the ceramic is undergoing a wetting or drying process. See the section on Calculations of Matric Suction for more details on this topic. GCTS FTC Sensor 6

Apparatus: Fredlund Thermal Conductivity Sensor (FTC Sensor) FTC Suction Sensors The field investigation plan determines the most suitable number of sensors for a particular project. It is possible to install up to 16 sensors on a project and have the sensors connected to one data acquisition system. Each sensor comes with 10 meters of electrical cable fitted with a connector. A photograph of a sensor is shown in Figure 3. The actual length of the cables required for a particular project can be determined based on the sensor installation layout. A typical sensor layout plan containing 15 sensors is shown in Figure 4. Additional lengths of cable required for a project need to be obtained separately. Figure 3. Photograph of FTC sensor. Datalogger The datalogger is powered by a 12-volt battery and accommodates 16 sensors via a 16-channel multiplexer. The datalogger can be connected to a PC, laptop, or a PDA via a USB port. The datalogger can be programmed to monitor the sensors for up to a 3- GCTS FTC Sensor 7

month period and the data generated is stored in non-volatile memory. At each reading event, the suction sensor controller (see Figure 5) delivers a constant current over a designated time period to each sensor and extracts the data from the heating curve. See Figure 2 for examples of heating curve responses. The datalogger comes with the software required to run the monitoring programs. The programs can be run in either a STANDALONE mode or a DIGITAL mode. The STANDALONE mode operates without an external computer and stores primary data (i.e. date, time, sensor identification, ambient temperature, and temperature rise) for up to a three-month period. The DIGITAL mode interfaces with a computer (i.e. PC, laptop, or PDA) directly and offers higher flexibility in operation. For example, in addition to the primary data, the entire heating curve can be retrieved for more detailed study in the DIGITAL mode. The electronics in the datalogger should be protected in the field by enclosing it in a weatherproof case. Mass of Soil/Waste Datalogger Edge of Excavation PVC Pipe Sensor Location (TYP) Cable (TYP) Figure 4. A sensor installation layout (Tan et al. 2003). GCTS FTC Sensor 8

LCD Display Reset Non- Volatile Memory RAM Microprocessor Power Running Commu Pressure RH/Temp Sensor Controller 12 VDC Power Supply USB Cable (TYP) PC Lap top 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 PDA Sensors 1 thru 16 Figure 5. A schematic of the GCTS datalogger. Installation Equipment Installation equipment required for a project depends on the physical site conditions and nature of the project. Earth moving equipment such as backhoes can be used to make a large-scale initial excavation, if this is necessary. Hand-held electrical augers, manual augers, extension rods, driving tools, tamping rods, and oil sampling tools are a few pieces of equipment that are valuable for actual sensor installation (Marjerison et al., 2001). GCTS FTC Sensor 9

17 16 15 Wetting Curve Drying Curve T ( o C) 14 13 12 11 10 0.1 1 10 100 1000 10000 Matric Suction (kpa) Figure 6. Typical calibration curve. Sensor Calibration Calibration curve represents the response of a sensor under an applied matric suction. The response is measured as a temperature rise in the sensor when a specific quantity of heat is applied to the ceramic. Due to hysteresis effects associated with the porous ceramics (Feng Man et al., 2002), the sensors respond differently during drying and wetting. Therefore, two calibration curves, one for drying and the other for wetting, are required to obtain the most accurate matric suction measurements in the field. A typical calibration curve is shown in Figure 6. Normally, batch calibration data associated with the drying curve is input to the datalogger and data reduction is automatically carried out. The ceramic sensors are manufactured in batches. Only one of the sensors from each batch of ceramics is subjected to the calibration procedure. The GCTS FTC Sensor 10

batch calibration is sufficient to provide adequate accuracy for the matric suction determination for most situations. However, if necessary, standard calibration or full calibration data can be measured on each suction sensor. Differences between the three calibration procedures are shown in Table 2. Table 2. Types of calibration procedures. Calibration Procedure Sensors Used Applied Suctions (kpa) (1M = 1,000,000) Steps Batch 1 per batch 0, 10, 100, 500, 1M* 5 Standard Individual 0, 10, 100, 500, 1M* 5 Full Individual 0, 10, 50, 100, 500, 1000, 1M* 7 * 1M suction is considered as the theoretical suction when the ceramic is completely dry. Field Test Procedure Suction sensors are applicable to a variety of engineering applications such as modeling seepage and contaminant movement in tailings and mine waste. The installation of durable field suction sensors can provide valuable data over a period of several years for a reasonable cost. Matric suction measurements are also useful in assessing the strength of an unsaturated soil for slope stability conditions (Fredlund and Rahardjo 1993). Another application of the sensors is to obtain measurements of matric suction beneath highway pavements and railway systems. The strength of a highway pavement system is mainly dependent upon temperature and moisture conditions beneath the pavement. Data from suction sensors installed in a highway test section can be effectively used in pavement design and the monitoring of performance. GCTS FTC Sensor 11

Preparation for Field Work A sensor installation plan must be prepared considering the nature of engineering application in hand and the site conditions. The sensor installation plan could include the information on number of sensors, sensor locations, excavation boundaries, method of excavation and backfilling, cable paths, location of datalogger, and monitoring plan. The monitoring plan should include the duration of the monitoring program, frequency of the readings, and the type of data needed (i.e. either primary data or primary data and heating curve data). The installation tools and supplies required for the project must be prepared. Excavation permits and access permits must be acquired, if these are necessary. Suction sensors also can be installed in boreholes provided that the boreholes are backfilled such that there is no preferential pathway for water movement through the backfilling. If sensors are to be installed in boreholes, a drill rig can be used for drilling and a special installation tools and backfilling procedures should be adopted. Installation of the Suction Sensors The site excavation should be conducted according to the plan. The locations where the sensors are to be installed should be maintained in an undisturbed condition as much as possible during excavation activities. Later backfill should be made to correspond approximately to the field density. The sensor locations are usually established by drilling with hand-held augers in approximately a horizontal direction. The sensor is then inserted into the hole. The hole is backfilled using the tamping tool ensuring that the cable is properly buried without any damage. It is preferred that sensors GCTS FTC Sensor 12

are installed in a horizontal direction rather than in vertical direction since vertical holes are more susceptible to providing unwanted avenues for water ingress. However, properly backfilled, vertical holes are also suitable for sensor installation in some situations. Once all the sensors are installed, the cables can be run to the location of the datalogger, preferably via a PVC conduit. The main excavation should be backfilled ensuring the backfilled density is approximately equal to the in situ density prior to the excavation. The installation is completed by connecting the cables to the datalogger and securing the datalogger in a weatherproof enclosure. Programming the Datalogger The datalogger needs to be programmed according to the monitoring plan. The initial tests can be performed using a PC, laptop, or the PDA directly sending signals to the sensors. In this way, the functionality of each sensor can be immediately determined. It is preferable to read the sensors less than or equal to four times per day allowing sensors to equilibrate at least six hours between the readings. Monitoring the Suction Sensors The installed sensors will take some time to reach equilibrium with the surrounding soil mass. Therefore, the initial readings taken during the first few days may not represent the true condition. In clayey soils, it may take as long as two weeks for complete equilibration with the surrounding environment. In silts and sands, less time may be required but it also depends on the magnitude of the matric suction. GCTS FTC Sensor 13

Calculation of Matric Suction The primary data collected from the suction sensors include the ambient temperature and temperature rise for each sensor. The temperature rise data should be reduced to obtain the suction corresponding to the calibration curve (i.e. drying mode). In the process, two corrections should be applied to the readings; namely the hysteresis correction and the ambient temperature correction. These corrections are built into the software in the datalogger and are automatically applied. The corrections can also be manually applied as described in the following paragraphs. Hysteresis Correction Depending on the direction of water movement in the soil (i.e. either wetting or drying of the soil), the correct calibration curve should be selected. The direction of moisture movement can be determined by considering a few readings just prior to the current reading. For example, the drying curve (see the curve shown as a solid line in Figure 6) is applicable if the current temperature rise is higher than the few previous readings; otherwise the wetting curve is applicable. Temperature Correction The temperature rise used for the calibration curve corresponds to a standard temperature of 23 o C. This is the temperature maintained in the laboratory during the calibration process. Temperature rises in the field at ambient temperatures can deviate from the laboratory calibration value. Therefore, a correction must be applied prior to entering the calibration curve. Nichol et al. (2003) proposed a correction for the field GCTS FTC Sensor 14

temperature. According to the Nichol et al. (2003) study, the correction is not only dependent on the ambient temperature but also dependent on the magnitude of the matric suction as shown in Figure 7. The field measured temperature rise is multiplied by the correction factor from Figure 7 to obtain the temperature rise that would have been measured at 23 o C. 1.03 Temperature Rise Correction Factor 1.02 1.01 1.00 0.99 0.98 0.97 0.96 0-10 kpa 20 kpa 50 kpa 100 kpa 400 kpa 0.95 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Ambient Temperature ( o C ) Figure 7. Correction factor for ambient temperature (Nichol et al. 2003). GCTS FTC Sensor 15

Reporting of Results The primary information to include in a report is the variation of matric suction and temperature with respect to time. Additional information such as environmental changes involving rainfalls and snowfalls can be included in the report to assist the analysis of the data. References 1. Feng, M., and Fredlund, D.G., (2003). Calibration of thermal conductivity sensors with consideration of hysteresis. Technical Note, Canadian Geotechnical Journal, 40(5), pp 1048-1055. 2. Feng, M., Fredlund, D.G., & Shuai, F. (2002). A laboratory study of the hysteresis of a thermal conductivity soil suction sensor. Geotechnical Testing Journal, 25(3), pp 303-314. 3. Fredlund, D.G. and Rahardjo, H. (1993). Soil mechanics for unsaturated soils. New York: John Wiley & Sons, Inc. 4. Fredlund, D.G., Shuai, F., and Feng, M. (2000). Increased accuracy in suction measurements using an improved thermal conductivity sensor. Proceedings of the Seventh International Conference on Tailing and Mine Waste, Fort Collins, Colorado, USA. pp 443-450. January 23-26. 5. Fredlund, D.G., Shuai, F., and Feng, M. (2000). Use of a new thermal conductivity sensor for laboratory suction. Proceedings of the Asian Conference on Unsaturated Soils, UNSAT ASIA 2000, Singapore. pp 275-280. May 18-19. 6. Fredlund, M.D., Fredlund, D.G., Houston, S.L., and Houston, W. N. (2003). Assessment of unsaturated soil properties for seepage modeling through tailings and mine wastes. Proceedings of the Tenth International Conference on Tailings and Mine Wastes, Vail, Colorado, USA. pp. 149-157. October 12-15. 7. Marjerison, B., Richardson, N., Widger, A., Fredlund D.G., and Berthelot, C. (2001). Installation of sensors and measurement of soil suction below thin membrane surface pavements in Saskatchewan. Proceedings of the 54th Canadian Geotechnical Conference, Calgary, Alberta. pp 1328-1334. September 16-19. GCTS FTC Sensor 16

8. Nichol, C., Leslie, S., and Beckie, R. (2003). Long-term measurement of matric suction using thermal conductivity sensors. Canadian Geotechnical Journal, 40, pp 587-597. 9. Padilla, J.M., Perera, Y.Y., and Fredlund, D.G. (2004). Performance of Fredlund Thermal Conductivity Sensor. Proceedings of Tailings and Mine Waste 2004, Vail, Colorado, USA. To be published. October 10-13. 10. Shuai, F., and Fredlund, D.G. (2000). Use of a new thermal conductivity sensor to measure soil suction. Proceedings of the GeoDenver Conference, Denver, Colorado, USA. pp 1-12. August 3-8. 11. Shuai, F., Clements C., Ryland L., and Fredlund, D.G. (2002). Some factors that influence soil suction measurements using a thermal conductivity sensor. Proceedings of the Third International Conference on Unsaturated Soils, UNSAT 2002, Recife, Brazil. pp 325-329. March 10-13. 12. Shuai, F., Fredlund, D.G., and Samarasekera L. (2003). Numerical simulation of water movement in the suction equalization of a thermal conductivity sensor. ASTM Geotechnical Testing Journal, 26(2), pp 142-151. 13. Tan, E., Marjerison, B., and Fredlund, D.G. (2003). Measurements and analysis of temperature and soil suction below thin membrane surface (TMS) in Saskatchewan. Proceedings of the 56th Canadian Geotechnical Conference, Winnipeg, Manitoba, Volume 2, pp 107-114. Sept. 29-Oct. 1. GCTS FTC Sensor 17