FW-KP WIRELESS KEYPAD

Similar documents
CSB 200. Microwave barrier. Outdoor Detector 200m Range DIGILON INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

alarm shop Outdoor PIR + MW Detector with Double Dual Mirror Optics INSTALLATION INSTRUCTIONS & USER MANUAL ELECTRONIC ENGINEERING LTD.

installation & operation manual

External Wireless Sounder

External Wireless Sounder

PowerWave-16. Users Operating and Programming Guide Version P/N Rev. B N.A July 2002

INSTALLATION INSTRUCTIONS and OPERATING GUIDE

RR-PM1200 OPERATING AND PROGRAMMING GUIDE

SHEPHERD. Smart solutions to protect and manage what matters the most to you

FW-RA-LED Remote Multiplex Annunciator Panels

INSTALLATION INSTRUCTIONS

Voice Module Installation Guide. For use with ProSYS 16, ProSYS 40, ProSYS 128

0$(6752 0$(6752. Programming Guide. 6 and 10 Zone Alarm Control Panel ,1752'8&7,21 +(;$ 352*5$00,1* 675($0/,1(' 6(&7,21 352*5$00,1* FIGURE 1 FIGURE 2

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

636 and 646 Keypads. User s Manual

The Icon Series. User Guide. CDV25 Version 1.0. Iconopm1.pm

RAM-208. Remote Multiplex Annunciator Panel. Wiring & Installation Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE

PART NO: TSMS. Designed in Australia by. Instruction Manual. Factory Car Alarm Upgrade Providing Alarm Notification Via SMS Messaging N517

DIGITAL FRONTIER Voice Alarm System DFA5300 User Manual Version 1 rev2

Use this product according to this instruction manual. Please keep this instruction manual for future reference.

OWNER S MANUAL. Remote Mobile Security System. Models: PL50 PL60

Vehicle Security System

Figure 1. These Installation Instructions -1- K4866 4/00 OmniProx Reader Model Series OP-10/20/30/40

Wireless Internal Siren System Installation Guide

640 Series Advanced Remote Vehicle Security System

HOME MANAGEMENT GATEWAY

Using Your GEM-P400 Security System H

FW-SIREN2EXT -8/9F FW-SIREN2CP -8/9F

Solar Powered Wireless Photobeam Sensors

Cellular Alarm Quick Start Installation Guide

SPECTRA 1727 USER S GUIDE

3820, 3820i, 4820, 4820i

LCD and 16-Zone LED Keypads. User s Manual

Power Wave LCD Keypads. Users Operating and Programming Guide Version 2.00

Voice Board. Installation and Programming Guide. Runner 4/8,PowerWave 4/8/16 &, Elite64. Add-on Board For Storing Recorded Voice Messages

Security Alarm System Owner's Guide 8 sector CDS Dialler 8-24 sector Control Dialler 8-24 sector Control Securitel Version 1.0 lcopm.

EasyLoader. End User Manual

10-Zone Spectra LED Keypads

Protégé Eclipse LED Keypad User Manual PRT-KLES

L900 series USER MANUAL

CA 120 Owners Manual of 10

REMOTE MOBILE SECURITY SYSTEM USER MANUAL

0$; Installation Instructions. Computerized Control Panel '(6&5,37,21 63(&,),&$7,216 DE5011 1

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

CD6102 / CD6102 OC / CD6102-2

installation instructions Fan Tray System FTA-3/FTA-6

USER MANUAL QSDL503AD Intelligent Auto-Dial Alarm System

Compact Equipment Warranty Policy

Radio Frequency Do s & Don ts

DUST FREE CARBON Whole House Air Purifier

RAM-216. Remote Multiplex Annunciator Panel. Wiring & Installation Manual COMMON TROUBLE A.C. ON SIGNAL SILENCED BUZZER SILENCE SIGNAL SILENCE

Macurco Single-Gas XL Series Monitor, CM-1XL Carbon Monoxide (CO), HS-1XL Hydrogen Sulfide (H2S) User Instructions

G34 AU1B (External Ultrasonic Sensor) Version 3

SERENITY. Crow s Passion for Smart Residential Security.

Using Your XP-600. Security System NAPCO NAPCO 2006 OI301B 4/06 1

INSTALLATION INSTRUCTIONS TALKBACK MODULE

Long Range Radio Alarm Transmitter

1 Watt Supervised Self-Amplified Strobe Speakers Round Flush Grille with 75cd Strobe

User s Guide Home Automation Wall Socket for IWATCHALARM (Add-On) Model: SM-001SK

CDMAEZ. CDMA Universal Alarm Communicator INSTALLATION & USER S GUIDE

Remote Relay Module (RRM)

Long Range Radio Alarm Transmitter

HEIGHTS KEY LOCK & SAFE 920 San Mateo NE Albuquerque, NM Contact us for more information

Module de relais Relay Module. Manuel de l utilisateur 301RW. User Manual ERP /07

PC56O. Instruction Manual

Remote Vehicle Control System. Security and Convenience System

ProTalk. Expander. Operating Manual Model B1292. July 28, 2009 Rev. 1.01

PRO-TEC SYSTEM ONE. Trailer Security Systems Model # PTS-2. Photo includes PTS-2 with optional pager unit

M113S Users Manual. MERLIN STEALTH M113S Electric Fence Energizer GROUP OF COMPANIES. PDF created with pdffactory trial version

OPERATING MANUAL. The Guardian Hand Held Security Metal Detector

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer. Users Manual

Operating Guide: for the Warmup Tempo Digital Programmable Thermostat Part of the Element Series

MODEL APS-15 REMOTE CONTROL AUTO SECURITY SYSTEM DU SYSTÈME DE SÉCURITÉ AUTO À COMMANDE À DISTANCE DE SEGURIDAD DE AUTOMÓVILES A CONTROL REMOTO

User s Manual For Model Aero-551 (Rev. Orig.)

No Touch Door Release Exit Sensor ACA-NTEB

Model 718W Owner's Guide

Remote Vehicle Control System

Wireless Base Remote Test and Hush

pure indoor living Remote Control TOWER FAN MODEL: BTF4011AR-CN

Using Your GEM-P800 Security System

User Guide K /05 TN LIC#: C-0183 C-0180 C-0685 AL LIC#: GA LIC#: LVA ARMED READY MESSAGE FUNC PANIC BACK

PodView Level Indicator LI40 Series Manual

Power Wave. 8 Zone Control Communicator. Crow Electronic Engineering P/L. Ver:8.54. Installation & Programming Guide.

Wireless Keypads LKP(E)S8M Series

Installation & Programming Guide

SCORPION Z16040C, Z8040C and Z5120C

Thermostat Series. Installation Manual TSTBM-RRS--TW-A Revised 02-13

Contents Security Products Catalogue

Preamplifier Power Supply PPS-02 user's guide

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

4500 THERMOSTAT INSTALLATION INSTRUCTIONS

PC51O2-433NA v1.0 Installation Manual

ALARM... CONTROL... PANELS... AND... KEYPADS...- WIRED...

Long Range Radio Alarm Transmitter

Owner s Manual. PIR-1 IR Learner

Duct Mount. Installation Instructions

Quick Start Guide for the Limitless Series WGLA Limit Switch used in conjunction with the Limitless WPMM Series ISSUE WARNING

IMPORTANT INFORMATION

NookBox Installation Guide Keypad. Installation Guide. NookBox Keypad (P / E )

AXI LED USER MANUAL (REV. 1.0)

Transcription:

ELECTRONIC ENGINEERING LTD. FW-KP WIRELESS KEYPAD INSTALLATION INSTRUCTIONS & USER MANUAL P/N 7101618 Rev. B ME-YS 1

The FW-KP is a wireless remote control keypad for POWERWAVE & RUNNER security and home automation control panels. The FW-KP enables easy programming, arming and disarming of the control panel. It also allows to control devices from anywhere in the home or office, using keypad commands. FEATURES: Designed to comply with European Standards Easy programming User-friendly operation Hand-held use and wall mounting Back light illumination Visual LED's indications Audible signals confirm user commands Up to 300 m range in open space FSK unique technology Keypads copy via smart EEPROM Up to 5 year lithium battery life Full Supervision MAKING YOUR FW-KP WORKING WITH A WIRELESS CONTROL PANEL 1. INSTALL THE FW-RCV. 2. ENROLL REQUIRED OPERATION RADIO SIGNAL (ARM /DISARM/STAY/CONTROL. 3. SET RADIO PANIC ALARM TO AUDIBLE OR SILENT. 4. ACTIVATE OUTPUT BY CHANNEL PANIC IF REQUIRED. 5. ACTIVATE OUTPUT BY RADIO CHANEL IF REQUIRED. 6. SET PENDANT CHIRPS FOR ARM/DISARM PARTITION A AND PARTITION B IF REQUIRED. ENROLLING RADIO CHANNELS In order to load a radio command on the panel, press the appropriate address number (e.g. P614E for channel 4). The keypad buzzer will beep once for a second to indicate learn mode has been initiated and the FW-RCV board LED will flash. The radio signal you wish to load must transmit a signal within 30 seconds from entering learn mode, otherwise the panel will time out and no code will be loaded. If a valid code is received within the 30 seconds the keypad will 2

give 3 short beeps and exit learn mode. To remove a loaded radio channel, enter in the code load address as above eg P614E, then without operating the transmitter and before the 30 second timer expires, press the Enter button. This will remove the code loaded against this address (in this case radio channel 4). HOW TO CHANGE OR ADD CODES Add: Getting into installer mode LED indication New User User 1 PROG INSTALLER PROG/ERR ENTER PROG 1 ENTER C O D E ENTER User 2 PROG INSTALLER ENTER PROG/ERR PROG 2 ENTER C O D E ENTER User 3 PROG INSTALLER PROG/ERR ENTER PROG 3 ENTER C O D E ENTER User 4 PROG INSTALLER PROG/ERR ENTER PROG 4 ENTER C O D E ENTER Remove : User 1 PROG INSTALLER ENTER PROG/ERR PROG User Number ENTER ENTER Installer PROG INSTALLER PROG/ERR ENTER PROG 0 ENTER NEW C O D E ENTER HOW TO ENROLL COMMANDS TO THE WIRELESS CONTROL PANEL? FIRST: Get into the address (left column below) and then proceed with enrolling procedure. Enroll: Press: Led indication Control panel enroll address ARM Button C O D E ARM PWR/TX PW8 PROG 611-618 ENTER RUNNER PROG 18 ENTER FW-64 PROG 550 ENTER PW8 PROG 611-618 ENTER DISARM Button C O D E DISARM PWR/TX RUNNER PROG 18 ENTER FW-64 PROG 550 ENTER STAY Button C O D E STAY PWR/TX PW8 PROG 611-618 ENTER RUNNER PROG 18 ENTER FW-64 PROG 550 ENTER PW8 PROG 611-618 ENTER CONTROL Button C O D E CONTROL PWR/TX RUNNER PROG 18 ENTER FW-64 PROG 550 ENTER 3

PANIC ( 1 &3 ) PRESS 1& 3 FOR 2 seconds PWR/TX PW8 PROG 611-618 ENTER RUNNER PROG 18 ENTER FW-64 PROG 550 ENTER HOW TO USE THE PLUG-IN DATA TRANSFER MODULE (DTU) Plug the DTU module (CROW P/N 0060330) to the black socket located at the back of the FW-KP. Read from DTU module PROG INSTALLER CODE ENTER COPY 9 ENTER Write to DTU module PROG INSTALLER CODE ENTER COPY 1 ENTER NOTE: When the SWITCH is not in WRITE position, the data in the DTU can not be written over. HOW TO RESTORE ALL TO FACTORY DEFAULTS? Remove the lithium battery and insert the battery again within 30sec' PROG INSTALLER CODE ENTER CLEAR & 9 Note: Press "CLEAR & 9" until the 3 panel indication LED's are blinking HOW TO INSTALL THE FW-KP? 4

HOW TO REPLACE BATTERY? CAUTION!!! RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS. The battery must be replaced by: 3.6V Lithium Battery Size: 1/2AA Models as: XL-050F ENERGY LS14250 SAFT 5

TECHNICAL SPECIFICATIONS Data Protocol Modulation Type Frequency band Identification Event Transmission Range in open space Battery Current Consumption FreeWave FSK 868MHz Unique ID serial number 24 bit Arm, Disarm, Stay, Control, Panic, Low Bat up to 300 m Lithium. 3.6V Type: XL-050F Size: 1/2AA Standby <1 μa Operator Mode ~16 ma Transmission ~30 ma Operating temperature Range Dimensions Weight (inc. battery) 0 C to +50 C 133mm x 75mm x 30mm 225 gr. This device complies with: European Council Directive EMC 89/336/EEC EN50130-4 EN301489 EN300220 EN50081. SAFETY 73/23/EEC EN60950 (ITE) 6

CROW ELECTRONIC ENGINEERING LTD. ("CROW") WARRANTY POLICY CERTIFICATE This Warranty Certificate is given in favor of the purchaser (hereunder the "Purchaser") purchasing the products directly from Crow or from its authorized distributor. Crow warrants these products to be free from defects in materials and workmanship under normal use and service for a period of 24 months from the last day of the week and year whose numbers are printed on the printed circuit board inside these products (hereunder the "Warranty Period"). Subject to the provisions of this Warranty Certificate, during the Warranty Period, Crow undertakes, at its sole discretion and subject to Crow's procedures, as such procedures are form time to time, to repair or replace, free of charge for materials and/or labor, products proved to be defective in materials or workmanship under normal use and service. Repaired products shall be warranted for the remainder of the original Warranty Period. All transportation costs and in-transit risk of loss or damage related, directly or indirectly, to products returned to Crow for repair or replacement shall be borne solely by the Purchaser. Crow's warranty under this Warranty Certificate does not cover products that is defective (or shall become defective) due to: (a) alteration of the products (or any part thereof) by anyone other than Crow; (b) accident, abuse, negligence, or improper maintenance; (c) failure caused by a product which Crow did not provide; (d) failure caused by software or hardware which Crow did not provide; (e) use or storage other than in accordance with Crow s specified operating and storage instructions. There are no warranties, expressed or implied, of merchantability or fitness of the products for a particular purpose or otherwise, which extend beyond the description on the face hereof. This limited Warranty Certificate is the Purchaser's sole and exclusive remedy against Crow and Crow's sole and exclusive liability toward the Purchaser in connection with the products, including without limitation - for defects or malfunctions of the products. This Warranty Certificate replaces all other warranties and liabilities, whether oral, written, (non-mandatory) statutory, contractual, in tort or otherwise. In no case shall Crow be liable to anyone for any consequential or incidental damages (inclusive of loss of profit, and whether occasioned by negligence of the Crow or any third party on its behalf) for breach of this or any other warranty, expressed or implied, or upon any other basis of liability whatsoever. Crow does not represent that these products can not be compromised or circumvented; that these products will prevent any person injury or property loss or damage by burglary, robbery, fire or otherwise; or that these products will in all cases provide adequate warning or protection. Purchaser understands that a properly installed and maintained product may in some cases reduce the risk of burglary, fire, robbery or other events occurring without providing an alarm, but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property loss or damage as a result. Consequently, Crow shall have no liability for any personal injury; property damage or any other loss based on claim that these products failed to give any warning. If Crow is held liable, whether directly or indirectly, for any loss or damage with regards to these products, regardless of cause or origin, Crow s maximum liability shall not in any case exceed the purchase price of these products, which shall be the complete and exclusive remedy against Crow. 7

CROW ELECTRONIC ENGINEERING LTD. ISRAEL: USA: Crow Electronic Engineering Ltd. 12 Kineret St. Airport City P.O. Box 293, Ben Gurion Airport, 70100 Tel: 972-3-9726000 Fax: 972-3-9726001 E-mail: support@crow.co.il 2160 North Central Road, Fort Lee, N.J. 07024 Tel: 1-800-GET CROW or (201) 944 0005 Fax: (201) 944 1199 E-mail: support@crowelec.com AUSTRALIA: 142 Keys Road Cheltenham Vic 3192 Tel: 61-3-9553 2488 Fax: 61-3-9553 2688 E-mail: crow@crowaust.com.au POLAND: VIDICON SP. ZO. O. 15 Povazkowska St. 01 797 Warsaw Poland Tel: 48 22 562 3000 Fax: 48 22 562 3030 E-mail: vidicon@vidicon.pl LATIN AMERICA: ITALY: CROW LATIN AMERICA 5753 NW 151 ST.Street MIAMI LAKES, FL 33014 USA Tel: +1-305-823-8700 Fax: +1-305-823-8711 E-mail: sales@crowlatinamerica.com DEATRONIC VIA Giulianello 4/14 00178 ROMA, ITALY Tel: +39-0676-12912 Fax: +39-0676-12601 E-mail: info@deatronic.com These instructions supersede all previous issues in circulation prior to Aug. 2009. 7101618_B.doc 8