FENVALERATE 200 EC Reg. No. L 4603 Wet/Act No. / Nr. 36 van / of 1947

Similar documents
BEFORE USING THIS PRODUCT READ THE LABEL CAREFULLY! ACEPHATE 750 SP. Reg. No. L 7181 Act/Wet No. 36 of/van 1947 N-AR 1929

WARNINGS Withholding periods: Minimum time between last application and harvest or feeding (f):

Display Carton / Uitstalkarton MAKHRO ROSE PROTECTOR Reg No L 8114 Act/Wet 36 / 1947

REACT 100 EC. Reg. No. L 9155 Act/Wet No. 36 of/van 1947

HUMOX. A concentrated Liquid Soil Conditioner made from renewable plant-derived organic matter containing fulvic acid.

Reg. no. L5456 Act/Wet 36 of/van 1947 FRAC FUNGICIDE GROUP CODE M4 FRAC SWAMDODERGROEPKODE ACTIVE INGREDIENT/AKTIEWE BESTANDDEEL

MILBEKNOCK 1% EC. Reg. No.: L 6654 Act No. 36 of 1947

Reg. No. L 8394 Act /Wet No. 36 of/van 1947

SHAKE THE BOTTLE WELL BEFORE USE. SKUD DIE BOTTEL GOED VOOR GEBRUIK. VIRON 480 SC. Reg. No. L 8815 Act/Wet No. 36 of/van 1947

Reg. No. L3655, Act No. 36 of 1947 Namibian Reg. No. N-AR 1205 Reg. Nr. L3655, Wet Nr. 36 van 1947 Namibiese Reg. Nr. N-AR 1205

Reg No L7649 Act/Wet Nr. / No. 36 of / van 1947 W INSECTICIDE GROUP 1A/3 INSEKDODERGROEP ACTIVE INGREDIENTS / AKTIEWE BESTANDDELE

Melody Duo. Melody Duo. Fungicide 69 WG. Packaging / Verpakking: 10 kg 69 WG

Before using this product read the label carefully. Cylam 50 EC

Reg. No. L 5409 Act/Wet No. 36 of/van 1947

IMIBOOST BLUE BAND. Active ingredient / Aktiewe bestanddeel : Ammonium sulphate g/l. Ammoniumsulfaat. Netto Volume l Net Volume

ODEON 720 SC Reg. No. / Nr. L 7596 Act No. / Wet Nr. 36 of / van 1947 N-AR 0913

BEFORE USING THIS PRODUCT READ THE LABEL CAREFULLY! PENCONAZOLE 200 EW. Reg. No. L 7492 Act/Wet No. 36 of/van 1947

Read the label carefully before opening

BEFORE USING THIS PRODUCT READ THE LABEL CAREFULLY! SHAKE THE BOTTLE WELL BEFORE USE. DETECT 400 SC. Reg. No. L 9238 Act/Wet No.

BEFORE USING THIS PRODUCT READ THE LABEL CAREFULLY! SHAKE THE BOTTLE WELL BEFORE USE. ELECTRON 500 SC

Flair. 1 l. IRAC INSECTICIDE GROUP CODE: UN ACTIVE INGREDIENT: Bromopropylate (benzilic acid ester) g/l

DIPEL DF. Reg No./Nr. L 6441 : Act/Wet 36/1947

Rappid K POTASSIUM POLYPHOSPHATE KALIUM POLIFOSFAAT FERTILIZER GROUP 1 MISSTOF GROEP 1

Reg. no. L5096 Act/Wet 36 of/van 1947 N-AR 0916 IRAC INSECTICIDE GROUP CODE 3A IRAC INSEKDODERGROEPKODE ACTIVE INGREDIENT/AKTIEWE BESTANDDEEL

MARSHAL 48EC Reg. no/nr L3314: Act/Wet no./nr. 36 of/van 1947 Namibian Reg. No. N-AR 0637

CLODINAGAN 240 EC Reg. No. L 8383 Act / Wet 36 / 1947 N-AR 1053

TRICHLORFON 950 SP. Reg. No. L 7407 Act/Wet No. 36 of/van 1947

TALENDO. Reg. No. L8116 Act No. 36 of 1947 Reg. Nr. L8116 Wet Nr. 36 van 1947 FUNGICIDE GROUP CODE 13 SWAMDODER GROEP KODE

COMPLETE 350 SC Reg. No.: L 9024 Act /Wet No. 36 of/van 1947

Plant Growth Regulator A defoliant and leaf regrowth

D E N A R I N E C reg no Reg. No. / Nr.: L 5210 Act / Wet 36/1947

SHAKE THE BOTTLE WELL BEFORE USE. SKUD DIE BOTTEL GOED VOOR GEBRUIK. MISSION 720 SC. Reg. No. L 8432 Act/Wet No. 36 of/van 1947

Packaging / Verpakking: 5 L

Reg. no. L5254 Act/Wet 36 of/van 1947 N-AR 0498; W IRAC INSECTICIDE GROUP CODE 1A IRAC INSEKDODERGROEPKODE

WARNINGS... 2 PRECAUTIONS... 2 SYMPTOMS OF HUMAN POISONING... 3 FIRST AID TREATMENT... 3 NOTE TO PHYSICIAN... 3 DIRECTIONS FOR USE...

Reg. no. L6034 Act/Wet 36 of/van 1947 N-AR 0504 FRAC FUNGICIDE GROUP CODE C FRAC SWAMDODERGROEPKODE ACTIVE INGREDIENT/AKTIEWE BESTANDDEEL

BUDBREAK. Reg. No. L5951, Act No. 36 of 1947 Reg. Nr. L5951, Wet Nr. 36 van 1947

250 EW. Fungicide A systemic fungicide emulsion, oil in water for the control of the diseases mentioned on the crops listed.

ETHAPON SL. Reg. No. L5023 Act No./ Wet Nr. 36 of / van 1947 A SOLUTION CONTAINING A PLANT GROWTH REGULATOR FOR USE IN THE CROPS AS LISTED.

Fungicide A fully systemic fungicide formulated as a water dispersible granule, for the control of the diseases mentioned on the crops listed.

Regulex 10 SG. Reg No./Nr. L5120 Act/Wet 36/1947

BROMOTRIL T. Reg. no. L6653 Act/Wet 36 of/van 1947 N-AR 0870 HRAC HERBICIDE GROUP CODE C3 & C1 HRAC ONKRUIDDODERGROEPKODE

1 l. UN Number: 3082 VERWYS NA BESONDERHEDE GEDRUK OP HOUER/SAK GEBRUIKSAANWYSINGS INGESLUIT. Formuleringsdatum: Date formulated:

Reg No L3459 Act/Wet Nr. / No. 36 of / van 1947

AVAUNT. Reg. No. L6678 Act No. 36 of 1947 Reg. Nr. L6678 Wet Nr. 36 van 1947 INSECTICIDE GROUP CODE 22 INSEKDODER GROEP KODE

SYLLIT. Reg. No.: L7423 Act /Wet No. 36 of/van ACTIVE INGREDIENT/AKTIEWE BESTANDDEEL: dodine (guanidine) / dodien (guanidine)..

SERGEANT. Reg. No.: L 9876 Act /Wet No. 36 of/van 1947 IRAC INSECTICIDE GROUP CODE: 13 IRAC INSEKDODERGROEP KODE:

Forestry and pastures. Marangatu Sementes

INSECTICIDE Reg No. L 4394 Act/Wet Nr. / No. 36 of / van 1947 ACTIVE INGREDIENT / AKTIEWE BESTANDDEEL

SAYONARA. Reg. No. L 9384, Act/Wet No/Nr 36 Of/Van1947 INSECTICIDE GROUP CODE 4A INSEKDODERGROEP KODE. Contents l Inhoud

UNIVERSAL PYRIPROXYFEN 100EC

TEBUZOLE 250 EW. Reg. No. L 7551 Act/Wet No. 36/1947

CHEMINOVA A/S CLIPLESS. Reg No./Nr L 8530 Act/Wet no./nr. 36 of/van Active Ingredient / Aktiewe Bestanddeel. Net contents / Netto Inhoud

Reg. No. L9149 Act No. 36 of 1947 Reg. Nr. L9149 Wet Nr. 36 van 1947 FUNGICIDE GROUP CODES 3 /11 SWAMDODER GROEP KODE

Read the label carefully before opening. Botswana: Reg. No. W130569, Act No. / Wet Nr. 18 of / van 1999

Insecticide A systemic water dispersible granule insecticide for the control of the insects mentioned on the crops listed.

BOTRYNIL. Reg. No./Nr. L 8271 Act/Wet No./Nr. 36 of/van 1947 FRAC FUNGICIDE GROUP CODE 9 FRAC SWAMDODERGROEPKODE

AKITO. Reg. No.: L 6709 Act /Wet No. 36 of/van 1947

Corona 250 EW FRAC FUNGICIDE GROUP 3 FRAC SWAMDODER GROEP. Active ingredient/aktiewe bestanddeel

Reg. no. L9255 Act/Wet 36 of/van 1947 N-AR 1394 IRAC INSECTICIDE GROUP CODE 4A & 3A IRAC INSEKDODERGROEPKODE ACTIVE INGREDIENT/AKTIEWE BESTANDDEEL

SHAKE THE BOTTLE WELL BEFORE USE. SKUD DIE BOTTEL GOED VOOR GEBRUIK. SPARTA PLUS 375 SC. Reg. No. L 9499 Act/Wet No.

ANTAGON. Reg. No. L 8842, Act/Wet No/Nr 36 Van/Of 1947 FRAC FUNGICIDE GROUP CODE M7 FRAC SWAMDODER GROEPKODE. Active ingredient/aktiewe bestanddeel:

Reg. No. L 5225 Act / Wet No. 36 of / van 1947 N-AR 1039 W INSECTICIDE GROUP 1 B INSEKDODERGROEP. Active Ingredient / Aktiewe Bestanddeel

SOLSTAR. Reg. No. L. 7968, Act/Wet No/Nr 36 Of/Van 1947 HRAC: HERBICIDE GROUP CODE O HRAC: ONKRUIDDODER GROEPKODE.

MAXIDOR Reg. No. L8771 Act No / Wet Nr 36 / 1947

Thiamex 25 WG. Reg. No.: L 9207 Act /Wet No. 36 of/van 1947

Read the label carefully before opening / Lees die etiket sorgvuldig voordat oopgemaak word MECTI

Read enclosed label for full details / Raadpleeg ingeslote etiket vir volle besonderhede MANCOLAX 700 WP

KLUB M5 DICARZOL. Reg. No. L 8082 (Act No. 36 of 1947)

METAZEB 700 WP. Reg. No. L 7463 Act/Wet No. 36 of/van 1947

BEFORE USING THIS PRODUCT READ THE LABEL CAREFULLY! SCALEX 100 EC. Reg. No. L 7573 Act/Wet No. 36 of/van 1947

Karba 50 DP. Reg. No. / Nr. L 1081 Act No. / Wet Nr. 36 of / van 1947

SHAKE THE BOTTLE WELL BEFORE USE. SKUD DIE BOTTEL GOED VOOR GEBRUIK. ARIA SC. Reg. No. L 7943 Act/Wet No. 36 of/van 1947

PHILAGRO SOUTH AFRICA DANTOP 20SC NEMESIS* 100 EC INSECTICIDE GROUP CODE 4A INSEKDODERGROEPKODE ACTIVE INGREDIENT / AKTIEWE BESTANDDEEL

SHAKE THE BOTTLE WELL BEFORE USE. SKUD DIE BOTTEL GOED VOOR GEBRUIK. ADDITION 150 SC. Reg. No. L 9146 Act/Wet No. 36 of/van 1947 N-AR 1508

Packaging / Verpakking: 1 L & Monodose (100 x 5 ml)

ACETOCHLOR 700 EC. Herbicide Group Code K 3

Valent BioSciences, a division of Philagro South Africa Pty Ltd/ n divisie van Philagro Suid Afrika Edms Bpk.

SCOPE 250 EC. Reg. No. L 7942 Act/Wet No. 36/1947

Rovral Flo. Reg. no. / Reg. nr. L1046 (Act No. 36 of 1947/ Wet Nr. 36 van 1947)

PHILAGRO S A S M I T E* Reg. No. L6011 Act /Wet No. 36 van / of / 1947 Amended April 2018 ACTIVE INGREDIENT / AKTIEWE BESTANDDELE:

Main Panel For further information see attached pamphlet Vir verdere inligting sien aangehegte pamflet DOUBLESTAR 25 SL

UNIVERSAL ENDOSULFAN EC

TANOS PRO. Reg. No. L8456 Act No. 36 of 1947 Reg. Nr L8456 Wet Nr 36 van 1947 FUNGICIDE GROUP CODE 27 / 11 / M4 SWAMDODER GROEP KODE

Fungicide A systemic emulsifiable concentrate fungicide for the control of the diseases mentioned on maize.

SALUTE WDG. Reg. No. L 8439 Act/Wet No. 36 of/van 1947

UN No. / VN Nr. 3077

Reg. no. L6515 Act/Wet 36 of/van 1947 N-AR0500; W IRAC INSECTICICIDE GROUP CODE 1B IRAC INSEKDODERGROEPKODE

MASTA 900 SP. Reg. No.: L 9449 Act /Wet No. 36 of/van ACTIVE INGREDIENT/AKTIEWE BESTANDDEEL: methomyl (carbamate) / metomil (karbamaat)

Reg. no. L9748 Act/Wet 36 of/van 1947 ACTIVE INGREDIENT/AKTIEWE BESTANDDEEL. Metamitron (triazinone) g/l... Metamitron (triasinoon)

METAMIDOFOS. Reg. No.: L 4531 Act /Wet No. 36 of/van 1947

STALLION 70 WS. Reg. No.: L 7991 Act /Wet No. 36 of/van 1947 IRAC INSECTICIDE GROUP CODE: 4A IRAC INSEKDODERGROEP KODE:

Seizer 80 SC. Reg. No. / Nr. L 7580 Act No. / Wet Nr. 36 of / van 1947

ALPHA-THRIN PEST KILL

CELTIS 25 EC. Reg. No.: L 7965 Act /Wet No. 36 of/van 1947

FRAC SWAMDODER GROEPKODE 9 & 12 FRAC FUNGICIDE GROUP CODE

BEFORE USING THIS PRODUCT READ THE LABEL CAREFULLY! SHAKE THE BOTTLE WELL BEFORE USE. SUPPORT 400 SC. Reg. No. L 9282 Act/Wet No.

Packaging / Verpakking: 1 L

Acrobat WG FUNGICIDES. Active ingredients: dimethomorph (cinnamic acid amides) g / kg mancozeb (dithio carbamate)...

Packaging / Verpakking: 1 L

Transcription:

FENVALERATE 200 EC Reg. No. L 4603 Wet/Act No. / Nr. 36 van / of 1947 An emulsifiable concentrate contact and stomach insecticide for the use on crops as indicated. INSECTICIDE GROUP 3A n Emulgeerbare konsentraat kontak-en maaginsekdoder vir die gebruik op gewasse soos aangedui. INSEKDODERGROEP ACTIVE INGREDIENT / AKTIEWE BESTANNEEL Fenvalerate (Pyrethriod) 200 g/l Fenvaleraat (Pirectroied) Net Volume Regsistered by AVIMA (PTY) LTD P. O. BOX 3131 KENMARE 1745, RSA Co. Reg. No. / Mpy Reg. Nr. 1961/01744/07 Netto volume Geregistreer deur Manufactured & Formulated by AVIMA (PTY) LTD 18 Aschenber Street, Chamdor, Krugersdorp, RSA Vervaardig & geformuller deur Batch No Date of Manufacture Lotnommer Vervaardigings datum UN No EMERGENCY NUMBER 3351 0800 172 743 UN Nr NOODNOMMER HARMFUL SKADELIK

WARNINGS THE FOLLOWING NUMBER OF DAYS MUST BE ALLOWED BETWEEN LAST APPLICATION AND HARVEST: Tomatoes... 2 days Potatoes... 3 days Peas and Beans... 7 days Apples... 14 days Maize... 14 days Pears... 14 days Grapes... 28 days Grainsorghum... 28 days Sunflower... 28 days Cotton (grazing)... 28 days Mangoes... 30 days *Warning against resistance : Resistance of American bollworm (Heliothis armigera) to synthetic pyrethroids has been confirmed. COTTON : Synthetic pyrethroids must ONLY be applied to cotton during the period 1 January to 28 February. ALL OTHER CROPS : DO NOT apply more than two applications per growing season. If a pyrethroid gives poor performance. DO NOT respray with any synthetic pyrethroid, even at a corrective dosage rate. Use a product from a different chemical group. Handle with care. Poisonous when swallowed, inhaled or absorbed through the skin. Extremely toxic to fish and bees. FLAMMABLE -Do not store near open flame. Store away from food and feeds and out of reach of children, animals and uninformed persons. AERIAL APPLICATION: Notify all inhabitants of the immediate area to be sprayed and issue the necessary warnings. Do not spray over or allow drift to contaminate water or adjacent areas. Although this remedy has been extensively tested under a large variety of conditions the registration holder does not warrant that it will be efficacious under all conditions because the action and effect thereof may be affected by factors such as abnormal climatic and storage conditions; quality of dilution water; compatibility with other substances not indicated on the label and the occurrence of resistance of the pest against the remedy concerned as well as by the method, time and accuracy of application. The registration holder furthermore does not accept responsibility for damage to crops, vegetation, the environment or harm to man or animal or for lack of performance of the remedy concerned due to failure of the user to follow the label instructions or to the occurrence of conditions which could not have been foreseen in terms of the registration. Consult the supplier or registration holder in the event of any uncertainty. 2

PRECAUTIONS Avoid inhalation of spray mist, oral intake and skin contact. In case of skin contact wash with soap and water. Wear protective clothing during application. Do not eat, drink or smoke while applying or preparing the spray mix, or before washing face and hands. Prevent spray drift onto other crops, grazing, rivers and dams. Prevent contamination of food, feeds, drinking water and eating utensils. RINSING OF CONTAINER : Invert the empty container over the spray or mixing tank and allow to drain for at least 30 seconds after the flow has slowed down to a drip. Thereafter rinse the container three times with a volume of water equal to a minimum of 10% of that of the container. Add the rinsings to the contents of the spray tank before destroying the container in the prescribed manner. Destroy empty container by perforation and flattening and never use for any other purpose. DIRECTIONS FOR USE : USE ONLY AS DIRECTED AERIAL APPLICATION Aerial application of FENVALERATE 200 EC may only be done by a registered aerial application operator using a registered and correctly calibrated aircraft according to the instructions of SANS Code 10118 (Aerial Application of Agricultural Pesticides). Ensure that the spray mixture is distributed evenly over the target area and that the loss of spray material during application is restricted to a minimum. It is therefore essential that the following criteria be met; Volume: A spray mixture volume of 30 l per hectare is recommended. As this product has not been evaluated at a reduced volume rate, the registration holder cannot guarantee efficacy, or be held responsible for any adverse effects if this product is applied aerially at a lower volume rate than recommended above. Droplet coverage: 30 to 40 droplets per cm² must be recovered at the target area. Droplet size: A droplet spectrum with a VMD of 250 to 280 microns is recommended. Limit the production of fine droplets less than 150 microns (high drift and evaporation potential) to a minimum. Flying height: Maintain the height of the spray boom at 3 to 4 metres above the target. Do not spray when aircraft dives, is in a climb or when banking. Use suitable atomizing equipment that will produce the desired droplet size and coverage, but which will ensure the minimum loss of product. The spraying system must produce a droplet spectrum with the lowest possible Relative Span. Position all the atomizers within the inner 60 to 75 % of the wingspan to prevent droplets from entering the wingtip vortices. The difference in temperature between the wet and dry bulb thermometers, of a whirling hygrometer, should not exceed 8 C. Stop spraying if the wind speed exceeds 15 km/h. Stop spraying under turbulent, unstable and dry conditions during the heat of the day. Spraying under temperature inversion conditions (spraying in or above the inversion layer) and/or high humidity conditions (relative humidity 80 % and above) may lead to the following: - reduced efficacy due to suspension and evaporation of small droplets in the air (inadequate coverage), 3

- damage to other sensitive crops and/or non-target areas through drifting of the suspended spray cloud away from the target field. Ensure that the Aerial Spray Operator knows exactly which fields to spray. Obtain an assurance from the Aerial Spray Operator that the above requirements will be met and that relevant data will be compiled in a logbook and kept for future reference. GENERAL: To obtain better emulsion stability it is recommended to first mix the concentrate with a small amount of water (one part to five parts of water) before adding the rest of the water. COMPATIBILITY: Can be used in combination with most insecticides and miticides normally used for sucking insects and mite control. DOSAGE RATES CROP AND PEST DOSAGE METHOD AND TIME OF APPLICATION POTATOES Potato tuber moth Low volume application 100 m/100 water (250 to 400 m/ha) Low volume application Commence application as soon as plants are one month old or sooner in case of early infestation. Use 250 to 400 of spray mixture/ha. The dosage rate will also control American bollworm and cutworm (in Western Cape) and will suppress aphids. Repeat application every 14 days. Volume of spray mixture to be applied depends on plant size. Plants should be ridged at least twice during the growing season. Aerial application 375 m/ha Aerial application Commence application as soon as plants are one month old or sooner in case of early infestation. Apply in at least 30 of. This dosage will also control American bollworm and suppress aphids. Plants should be ridged at least twice during the growing season. 4

CROP AND PEST DOSAGE METHOD AND TIME OF APPLICATION APPLES AND PEARS Codling moth High volume application 12 m/ 100 water (300 to 420 m/ha) High volume application Use between 2 500 and 3 500 of spray mixture/ha. Banded fruit weevil (Snout beetle) GRAINSORGHUM American bollworm MANGOES Mango weevil Low volume application 250 to 350 m/ha High volume application only 15 m/100 water (375 to 525 m/ha) Aerial application 200 m/ha High volume full cover application 30 m/100 water Low volume application Use in 400 to 800 of. Commence application at 75% petal fall. Repeat every 14 days. American bollworm and leafrollers will also be controlled. High volume application only Use between 2 500 and 3 500 of spray mixture/ha. Apply 2 to 3 full cover sprays. The first spray should be applied at 75% petal drop and the second 4 weeks later. If necessary a third application can be made in mid-january. These sprays will also control codling moth, leafrollers and American bollworm. Aerial application Use in at least 30 litre of as soon as infestation is noticed. Scout fields at 7 day intervals from the time of ear emergence using a sample of 25 plants/15 ha. Commence treatment when 10 % of the ears have a mean of one or more larvae. Where cultivars with tight ears are encountered, it is preferable to spray before the ears close up. (Before the grain fill out completely). High volume full cover application Apply as a full cover high volume double application. Apply during winter prior to flowering. Repeat when fruit is approximately 15 mm in diameter. NOTE: Under conditions of high infestation complete control may not be obtained. 5

CROP AND PEST DOSAGE METHOD AND TIME OF APPLICATION SUNFLOWERS American bollworm Aerial application 150 m/ha or 100 m + 450 m Methomyl 200 g/ litre/ha e.g. Methomyl 200 SL (Reg. No. L3480) Aerial application Commence application as soon as eggs or larvae are noticed on the plants (+ 6 weeks after planting). Use in at least 30. Only effective against larvae on the outside of the heads. LARVAE THAT HAVE ALREADY ENTERED THE HEADS WILL NOT BE KILLED. FENVALERATE 200 EC IS TOXIC TO BEES AND OTHER POLLINATORS AND SHOULD NOT BE APPLIED DURING FLOWERING TOMATOES American bollworm High volume application 15 m/100 water (150 to 600 m/ha) High volume application Use between 1 000 and 4 000 of spray mixture/ha, depending on plant size and density. Commence application as soon as eggs or larvae are noticed. Repeat application at 7 to 10 day intervals. WINE AND TABLE GRAPES Snoutbeetle (Phlyctinus callosus and Eremnus cerealis) BEANS AND PEAS American bollworm High volume application 15 m/100 water Aerial application 150 m/30 Ground application 150 m/300 to 500 High volume application Preferably with hand guns. Ensure thorough coverage of leaves as well as stems and the soil in the immediate contact with the stems. Monitor vineyards regularly for the presence of beetles. Apply the first spray at the first sign of beetle activity. Repeat 3 to 4 weeks later. Scout fields when flowering, using a sample size of 25 plants/ha. Commence treatment when 10% of the plants are infested with an average of 1 to 2 larvae. Scouting after application and after rain is still necessary. If rain falls shortly after application, wait 3 days, rescout and respray if necessary. 6

CROP AND PEST DOSAGE METHOD AND TIME OF APPLICATION ALL CROPS Cutworm Overall ground application 0-20% clay: 100 m/300 >20% clay: 125 m/300 Aerial application 0-20% clay: 120 m/30 >20% clay: 140 m/30 Spraying should only be done when the top 3 cm of soil is moist. Application can be done at planting as a preventative measure or can be applied as a corrective measure after planting as soon as infestation is noticed. MAIZE Stalkborer (Busseola fusca) Ground application 4 m/3 water/ 100 m row Ground application Direct spray into the funnel. Apply as a preventative treatment against young larvae 7 to 10 days after eggs are found on not more that 5% of the plants. A second application 10 to 14 days after the first may be necessary. Corrective treatment Apply in 3 of water, when 10% of plants show "shothole" damage. Larvae should not exceed 10 mm in length. Apply prior to the larvae entering the stalk. Only apply to actively growing plants up to the stage before the tassels are enclosed by the flag leaf. 7

CROP AND PEST DOSAGE METHOD AND TIME OF APPLICATION COTTON American, Red and Spiny bollworm, Plusia Looper, Stainers See "Warning against resistance" under WARNINGS. In order to comply with the principles of pest management and integrated control measures, FENVALERATE 200 EC is recommended to be used commencing at flowering, until boll split, i.e. approximately 10 to 22 weeks after plant emergence. During the period up to flowering, *AVI-SULFAN EC (Reg. No. L1085) is recommended for use against American bollworm or *KARBASPRAY 850 WP (Reg. No. L1195) for Red bollworm and stainers. For the first 12 weeks After 12 weeks It is recommended that FENVALERATE 200 EC be applied according to weekly scouting figures once the following threshold level has been reached: 5 American bollworm larvae or 2 Red bollworm larvae per 2 plants per 15 hectare; or 2 Spiny bollworm larvae or 6 Red bollworm eggs per 24 plants per 15 hectare. 5 Larvae of total bollworm complex per 24 plants per 15 hectare. Ensure adequate penetration of spray mixture is obtained to achieve optimum results particularly in tall dense plant populations. PREVENTIVE WEEKLY PROGRAMME (seven day intervals) 125 m/ha 100 m/ha 250 m/ha 200 m/ha Plants: 0-60 cm AERIAL: Apply in 30 GROUND: Apply in 100 "TRAMLINE": 1 m/1 water/100 m row Plants: 60 cm or older than 12 weeks AERIAL: Apply in 30 GROUND: Apply in 100 "TRAMLINE": 2 m/2 water/100 m row 8

CROP AND PEST DOSAGE METHOD AND TIME OF APPLICATION EMERGENCY CORRECTIVE TREATMENT 250 m/ha Plants: 0-60 cm AERIAL: Apply in 30 GROUND: Apply in 100 "TRAMLINE": 2,5 m/ 1 water/ 100 m row. 500 m/ha Plants: 60 cm or older than 12 weeks AERIAL: Apply in 30 GROUND: Apply in 100 "TRAMLINE": 5 m/2 water/100 m row RECOMMENDED CLIMATOLOGICAL SITUATION DURING AERIAL APPLICATION Stop application when wind exceeds 15 km per hour. Stop application when the difference between wet and dry bulb thermometer exceeds 8 o C. Do not spray plants if they are wet from dew or rain. If rain falls after application, scouting must be repeated three days later and if counts are still above the economical threshold, then application must be repeated. *L1085 Avi-Sulfan EC is a registered product by Avima (Pty) Ltd *L1195 Karbaspray 850 is a registered product by Villa Crop Protection 9

WAARSKUWINGS DIE VOLGENDE AANTAL DAE MOET VERLOOP TUSSEN DIE LAASTE TOEDIENING EN OES: Tamaties... 2 dae Aartappels... 3 dae Ertjies en Bone... 7 dae Appels... 14 dae Mielies... 14 dae Pere... 14 dae Druiwe... 28 dae Graansorghum... 28 dae Sonneblom... 28 dae Katoen (beweiding)... 28 dae Mango's... 30 dae * Waarskuwing teen bestandheid : Weerstand van Amerikaanse bolwurm (Heliothis armigera) teen sintetiese piretroïedes is bevestig. KATOEN : Sintetiese piretroïedes MOET SLEGS gedurende die periode 1 Januarie tot 28 Februarie op katoen toegedien word. ALLE ANDER GEWASSE : Moet nie meer as twee toedienings per groeiseisoen toedien nie. As 'n piretroïedbespuiting swak beheer gee MOET NIE met enige sintetiese piretroïed, selfs teen 'n korrektiewe dosis, herspuit nie. Gebruik 'n produk uit 'n ander chemiegroep. Hanteer versigtig. Giftig deur inname, inaseming of wanneer deur die vel geabsorbeer. Uiters giftig vir visse en bye. VLAMBAAR -Moenie naby oop vlamme stoor nie. Bêre weg van voedsel en voer en hou buite bereik van kinders, diere en oningeligte pesone. LUGTOEDIENING: Stel alle inwoners in die nabye omgewing van die lugbespuitingsarea in kennis en reik die nodige waarskuwings uit. Voorkom besoedeling en wegdrywe van spuitnewel na water of aangrensende gewasse en gebiede. Alhoewel hierdie middel omvattend onder 'n groot verskeidenheid toestande getoets is, waarborg die registrasiehouer nie dat dit onder alle toestande doeltreffend sal wees nie aangesien die werking en effek daarvan beïnvloed kan word deur faktore soos abnormale klimaats- en bergingstoestande; kwaliteit van verdunningswater; verenigbaarheid met ander stowwe wat nie op die etiket aangedui is nie en die voorkoms van weerstand van die plaag teen die betrokke middel sowel as die metode, tyd en akkuraatheid van toediening. Verder aanvaar die registrasiehouer nie verantwoordelikheid vir skade aan gewasse, plantegroei, die omgewing of vir nadelige effek op mens en dier of vir 'n gebrek aan prestasie van die betrokke middel as gevolg van die versuim deur die gebruiker om etiketaanwysings na te kom of as gevolg van die ontstaan van toestande wat nie kragtens die registrasie voorsien kon word nie. Raadpleeg die verskaffer of registrasiehouer in geval van enige onsekerheid. 10

VOORSORGMAATREËLS Voorkom inaseming van spuitnewel asook velkontak en inname deur die mond. Dra beskermende klere gedurende toediening. In geval van velkontak was met seep en water. Moenie eet, drink of rook tydens toediening of voorbereiding nie, of voordat gesig en hande gewas is nie. Voorkom oorwaai van spuitnewel na ander gewasse, weiding, damme en riviere. Voorkom besoedeling van voedsel, voer, drinkwater en eetgerei. UITSPOEL VAN HOUER : Keer die leë houer om oor die spuittenk of mengbak en dreineer vir minstens 30 sekondes nadat die vloei tot 'n gedrup verminder het. Spoel die houer daarna drie keer uit met 'n volume water gelykstaande aan 'n minimum van 10 % van die houer. Gooi die spoelwater by die inhoud van die spuittenk voordat die houer op die voorgeskrewe wyse vernietig word. Vernietig leë houer deur gate daarin te maak en plat te druk. Moet vir geen ander doel gebruik word nie. GEBRUIKSAANWYSINGS: GEBRUIK SLEGS SOOS AANGEDUI LUGTOEDIENING FENVALERATE 200 EC kan slegs deur n geregistreerde Lugbespuitingsoperateur met n korrek gekalibreerde, geregistreerde vliegtuig volgens die instruksies van SANS Kode 10118 (Aerial Application of Agricultural Pesticides) uit die lug bespuit word. Verseker dat die spuitmengsel eweredig oor die teikenarea versprei word, en die verlies aan spuitmengsel tydens toediening tot n minimum beperk word. Dit is daarom belangrik om aan die volgende vereistes te voldoen: Volume: 'n Spuitmengsel volume van 30 liter per hektaar word aanbeveel. Hierdie produk is nie teen 'n verlaagde volume getoets nie. Die registrasiehouer kan nie effektiwiteit waarborg, of verantwoordelik gehou word vir enige nadelige effekte indien hierdie produk teen 'n laer volume, as hierbo aanbeveel, toegedien word nie. Druppelbedekking: 30 tot 40 druppels per cm² moet op die teikenarea herwin word. Druppelgrootte: 'n Druppelspektrum met 'n VMD van 250 tot 280 mikrons word aanbeveel. Beperk die produksie van druppels kleiner as 150 mikrons (hoë drywing en verdampingspotensiaal) tot 'n minimum. Vlieghoogte: Handhaaf die hoogte van die spuitbalk bo die teiken op 3 tot 4 meter. Moet nie spuit wanneer die vliegtuig duik, uitklim of draai nie. Gebruik geskikte atomiseringsapparaat wat die vereiste druppelgrootte en bedekking sal produseer, maar die minste verlies van produk verseker. Die spuitstelsel moet n druppelspektrum met die kleinste moontlike Relatiewe Span produseer. Plaas al die atomiseerders in die binneste 60 tot 75 % van die vlerkspan om te verhoed dat druppels binne-in die vlerkpuntvorteks beweeg. Die verskil in temperatuur tussen die nat- en droëboltermometer van 'n swaaihigrometer, moet nie 8 C oorskry nie. Stop bespuiting indien die windspoed 15 km/h oorskry. Stop bespuiting tydens turbulente, onstabiele en droë toestande gedurende die hitte van die dag. Bespuiting onder temperatuur inversie toestande (deur bo of binne die inversie laag te spuit) en/of hoë lugvog toestande (relatiewe humiditeit 80 % en meer) mag tot volgende probleme aanleiding gee: 11

- verlaagde effektiwiteit aangesien die druppels as 'n wolk in die lug bly hang en moontlik verdamp (onvoldoende bedekking op teiken), - skade aan nie-teiken gewasse of sensitiewe areas as gevolg van wegdrywing van die spuitwolk na nie-teiken area. Verseker dat die Lugbespuitingsoperateur presies weet watter lande bespuit moet word. Dit is noodsaaklik om 'n versekering van die Lugbespuitingsoperateur te verkry dat aan al die bogenoemde vereistes voldoen sal word en dat data van belang in n logboek saamgevat is vir toekomstige verwysing. ALGEMEEN: Vir verbeterde emulsiestabiliteit word aanbeveel dat die konsentraat eers met 'n klein hoeveelheid water gemeng word (1 deel op 5 dele water) voordat die res van die water bygevoeg word. VERENIGBAARHEID: Verenigbaar met die meeste insek- en mytdoders wat normaalweg teen suigende insekte en myte gebruik word. DOSISSE GEWAS EN PLAAG DOSIS METODE EN TYD VAN TOEDIENING AARTAPPELS Aartappelmot Lae volume toediening 100 m/100 water (250 tot 400 m/ha) Lae volume toediening Begin toediening sodra plante een maand oud is of vroeër indien besmetting voorkom. Dien 250 tot 400 spuitmengsel per hektaar toe. Die dosis sal ook Amerikaanse bolwurm en snywurm (in Wes-Kaap) beheer. Sal plantluise onderdruk. Herhaal toediening elke 14 dae. Die hoeveelheid spuitmengsel hang af van plantgrootte. Plante moet minstens twee keer gedurende die groeiseisoen opge-erd word. 12

GEWAS EN PLAAG DOSIS METODE EN TYD VAN TOEDIENING AARTAPPELS (verv.) Aartappelmot Lugtoediening 375 m/ha Lugtoediening Begin toediening sodra plante een maand oud is of vroeër indien besmetting vroeër opgemerk word. Dien toe in minstens 30. Die dosis sal ook Amerikaanse bolwurm beheer en plantluise onderdruk. Plante moet minstens twee keer gedurende die groeiseisoen opge-erd word. APPELS EN PERE Kodlingmot Snuitkewers Hoë volume toediening 12 m/ 100 water (300 tot 420 m/ha) Lae volume toediening 250 tot 350 m/ha Hoë volume toediening alleenlik 15 m/100 water (375 tot 525 m/ha) Hoë volume toediening Gebruik 2 500 tot 3 500 spuitmengsel/ ha. Lae volume toediening Gebruik 400 tot 800. Begin toedien by 75 % blomblaarval. Herhaal elke 14 dae. Sal ook Amerikaanse bolwurm en bladrollers beheer. Hoë volume toediening alleenlik Gebruik 2 500 tot 3 500 spuitmengsel/ ha. Dien 2 tot 3 volle dekbespuitings toe. Die eerste by 75 % blomblaarval en die tweede vier weke later. Indien nodig kan 'n derde toediening teen middel Januarie gemaak word. Hierdie bespuiting sal ook kodlingmot, bladrollers en Amerikaanse bolwurm beheer. 13

GEWAS EN PLAAG DOSIS METODE EN TYD VAN TOEDIENING GRAANSORGHUM Amerikaanse Lugtoediening Lugtoediening bolwurm 200 m/ha Verken lande met 7 dae tussenposes vanaf tyd van aarverskyning. 'n Monstergrootte van 25 plante per 15 ha word aanbeveel. Begin spuit wanneer 10 % van die are (gemiddeld met een of meer larwes) besmet is.gebruik in minstens 30 sodra besmetting opgemerk word. In geval van kultivars met digte stywe are is dit wenslik om te spuit voordat die are toemaak (voordat korrels heeltemal uitgevul het). MANGO'S Mango snuitkewer SONNEBLOM Amerikaanse bolwurm Hoë volume volle dekbespuiting 30 m/100 water Lugtoediening 150 m/ha of 100 m + 450 m Methomyl 200 g// ha. Methomyl 200 SL (Reg nr. L3480) Hoë volume volle dekbespuiting Dien toe as 'n hoë volume volle dekbespuiting. Eerste toediening tydens winter voor die bome blom. Herhaal wanneer die vrugte ongeveer 15 mm in deursnee is. LET WEL: As die besmettingsdruk baie hoog is, is dit onwaarskynlik dat die beheer baie goed sal wees. Lugtoediening Begin toediening sodra eiers of larwes op plante waargeneem word (+ 6 weke na plant). Gebruik in minstens 30. Slegs effektief teen larwes op die blare en aan die buitekant van koppe. LARWES WAT IN DIE KOP OF IN DIE BLOMGEDEELTES IS, SAL NIE BEHEER WORD NIE. FENVALERATE 200 EC IS GIFTIG VIR BYE EN ANDER BESTUIWERS EN MOENIE TYDENS BLOMSTADIUM AANGEWEND WORD NIE. 14

GEWAS EN PLAAG DOSIS METODE EN TYD VAN TOEDIENING TAMATIES Amerikaanse bolwurm Hoë volume toediening 15 m/100 water (150 tot 600 m/ha) Hoë volume toediening Gebruik tussen 1 000 en 4 000 spuitmengsel/ha, afhangende van plantgrootte en digtheid. Begin toediening sodra eiers of larwes waargeneem word. Herhaal toediening met 7 tot 10 dae tussenposes. WYN- EN TAFELDRUIWE Snuitkewers (Phlyctinus callosus en Eremnus cerealis) BONE EN ERTE Amerikaanse bolwurm Hoë volume toediening 15 m/ 100 water Lugtoediening 150 m/ 30 Grondtoediening 150 m/300 tot 500 Hoë volume toediening Verkieslik met handstange. Sorg vir deeglike bedekking van blare sowel as stamme en die grond onmiddellik rondom die stamme. Ondersoek wingerde gereeld vir teenwoordigheid van kewers. Begin spuit wanneer die eerste kewers waargeneem word. Herhaal die bespuiting 3 tot 4 weke later. Lande moet weekliks vanaf eerste blom verken word. 25 plante per hektaar word vir die doel aanbeveel. Bespuiting moet 'n aanvang neem wanneer 10 % van die plante met gemiddeld 1 tot 2 larwes besmet is. Verkenning na bespuiting en na reën is steeds nodig. Indien reën kort na bespuiting val, wag drie dae, verken en spuit weer indien nodig. 15

GEWAS EN PLAAG DOSIS METODE EN TYD VAN TOEDIENING ALLE GEWASSE Snywurm Algehele grondtoediening 0-20% klei: 100 m/300 >20% klei: 125 m/300 Daar moet slegs gespuit word indien die boonste 3 cm van die grond klam is. Snywurm MIELIES Stronkboorder (Busseola fusca) Lugtoediening 0-20% klei: 120 m/30 >20% klei: 140 m/30 Grondtoediening 4 m/3 water/ 100 m ry Toediening kan tydens plant as 'n voorkomende maatreël toegedien word of kan as 'n korrektiewe maatreël na plant toegedien word, sodra 'n besmetting opgemerk word. Grondtoediening Rig bespuiting in die kelk in. Dien toe as 'n voorkomende behandeling teen jong larwes, 7 tot 10 dae nadat eiers op nie meer as 5 % van die plante voorkom. 'n Tweede toediening 10 tot 14 dae na die eerste, mag nodig wees. Korrektiewe behandeling Dien toe in 3 water wanneer 10 % van die plante "haelskade" vertoon, mits larwes nie langer as 10 mm is nie. Behandel alvorens die larwes die stam binnedring. Dien slegs toe op aktiefgroeiende plante tot voor pluim in vlagblaar toegerol is. 16

GEWAS EN PLAAG DOSIS METODE EN TYD VAN TOEDIENING KATOEN Amerikaanse-, rooien stekel-bolwurm, Plusia landmeter en vlekbesie Vir die eerste 12 weke Na 12 weke Sien "Waarskuwing teen bestandheid" onder WAARSKUWINGS bo. Om te voldoen aan die vereistes van plaagbestuur en geïntegreerde beheermetodes word FENVALERATE 200 EC aanbeveel om tydens die hoofblomperiode tot bolbarstyd, d.i. ongeveer 10 tot 22 weke na opkom van saailinge, gebruik te word. Totdat die plante blom, word *AVI-SULFAN EC (L1085) vir die beheer van Amerikaanse bolwurm aanbeveel of *KARBASPRAY 850 WP (L1195) vir die beheer van rooibolwurm en vlekbesie. Dit word aanbeveel dat FENVALERATE 200 EC toegedien word aan die hand van weeklikse verkennings, sodra die volgende drumpelwaardes bereik word: 5 Amerikaanse bolwurmlarwes of 2 rooibol-wurmlarwes per 24 plante per 15 hektaar; of 2 stekelbolwurmlarwes of 6 rooibolwurmeiers per 24 plante per 15 hektaar. 5 Larwes van totale bolwurmkompleks per 24 plante per 15 hektaar. Verseker deeglike penetrasie van die spuitmengsel vir optimale beheer. Dit is veral belangrik as die plante baie dig groei. VOORKOMENDE WEEKLIKSE PROGRAM (sewe dae tussenposes) 125 m/ha 100 m/ha 250 m/ha 200 m/ha Plante: 0-60 cm LUG: Dien toe in 30 GROND: Dien toe in 100 "SPOORLYNE": 1 m/1 water/100 m ry Plante: 60 cm of ouer as 12 weke LUG: Dien toe in 30 GROND: Dien toe in 100 "SPOORLYNE": 2 m/2 water/100 m ry 17

GEWAS EN PLAAG DOSIS METODE EN TYD VAN TOEDIENING LAAT KORREKTIEWE BEHANDELING 250 m/ha Plante: 0-60 cm LUG: Dien toe in 30 GROND: Dien toe in 100 "SPOORLYNE": 2,5 m/1 water/100 m ry 500 m/ha Plante: 60 cm of ouer as 12 weke LUG: Dien toe in 30 GROND: Dien toe in 100 "SPOORLYNE": 5 m/2 water/100 m ry AANBEVOLE KLIMATOLOGIESE TOESTANDE TYDENS LUGTOEDIENING: Staak bespuiting as windspoed meer as 15 km per uur is. Staak bespuiting as die verskil tussen nat- en droë boltermometer meer as 8 o C is. Moenie plante spuit as dit nat gedou of gereën is nie. Indien 'n reënbui na 'n bespuiting voorkom moet die plante na drie dae weer verken word en indien telling nog bokant drumpelwaarde is, moet die bespuiting herhaal word. *L1085 Avi-Sulfan EC is n geregistreerde produk deur Avima (Pty) Ltd *L1195 Karbaspray 850 is n geregistreerde produk deur Villa Crop Protection 18