BANK UNDERDRAIN (ALTERNATE LOCATION) (PIPE SHALL BE WRAPPED WITH GEOTEXTILE) DRAINAGE LAYER GRANULAR MATERIAL CLASS II 3" NOMINAL DEPTH

Similar documents
SILT FENCE MACHINE SLICED ERO-1A STEEL FENCE POST (T-POST), MINIMUM 5' LONG, 6' MAXIMUM SPACING.

FEB 2016 COUNTY MAP NTS

ROADWAY SECTION PRINCIPAL ARTERIAL 2-01

SPL-2.2 MECHANICALS POOL LAWN. 3rd FLOOR TERRACES AMENITY RESTAURANT 230 EAST AVENUE AMENITY NORWALK, CT

Preparing a Stormwater Control Plan for a Small Land Development Project

SECTION DUCTWORK. A. Section Painting: Weld priming, weather resistant, paint or coating.

Erosion Control for Home Builders in the. City of Jacksonville

WQ-07 INFILTRATION TRENCH

ROME CANALWAY TRAIL ERIE BOULEVARD WEST AND SOUTH CHARLES STREET ROME, NEW YORK DELTA PROJECT NO SEPTEMBER 2017 ISSUED FOR BID

Urban Conservation Practice Physical Effects ESTABLISHMENT, GROWTH, AND HARVEST NUTRIENT MANAGEMENT

Revetting and Supporting River Banks 4.7 Bank revetment using low steel sheet piling and coir rolls

12/31/2014 County of Mendocino s Low Impact Design Standards Manual v1.0 A P P E N D I X 8. Site Design Measures. 32 P a g e

5. LOW IMPACT DEVELOPMENT DESIGN STANDARDS

FireMaster Instrument cable tray fire protection

INSTALLATION GUIDELINES. Landfills and mines

Stormwater Control Plan: Small (Tier 1) Land Development Project

ABBREVIATIONS: TABLE OF CONTENTS: REFERENCE MATERIALS: CITY OF SEATTLE COMBINED SEWER OVERFLOW GALLONS PER MINUTE POLYVINYL CHLORIDE SQUARE FEET

III.DRAINAGE. This section describes the use of geotextiles in underdrains for two different field conditions:

511 - RIP RAP - OPSS 511 ROCK PROTECTION - OPSS 511 GRAVEL SHEETING - OPSS 511 GEOTEXTILE - OPSS 511

INSTALLATION GUIDELINES FOR GEOTEXTILES USED IN FILTRATION AND DRAINAGE APPLICATIONS

Tree Pits Construction Guide

B511 - RIP-RAP, ROCK PROTECTION AND GRANULAR SHEETING - OPSS 511

Please make the following changes in your copy of the bid proposal for the captioned project:

6.2 Flow-Through Planter

NOTICE OF INTENT. Submitted To: Bremo Power Station 1038 Bremo Bluff Road Bremo Bluff, VA 23022

DRIVABLE GRASS GUIDELINE FOR PLANTED INFILL INSTALLATION

INFILTRATION TRENCH - LEAKY PIPE

A. Install all temporary erosion control measures (in accordance with MNDOT General Conditions 2573) prior to site disturbance.

Feet. Overland. Drainage Area Boundary. To Swale. Swale. To Catch Basin. Culvert Pipe. To Drain Outfall. NRCS Soil Area Boundary

PROJECT AND PUBLIC UTILITY CONTACTS VILLAGE OF BEAR LAKE PO BOX VIRGINIA STREET BEAR LAKE, MI (231) VILLAGE OF BEAR LAKE

2. HORIZONTAL DATUM = NAD 83. VERTICAL DATUM = NAVD 88.

SECTION PLANTING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Analyzing the Bioretention Construction Sequence

V. EROSION CONTROL. -Drainage swales separation -Under rip-rap protected -Under rip-rap unprotected


Appendix G. Detailed Design

THE OBJECTIVES OF ROUTINE ROAD CUTS AND FILLS

SECTION 900 TURF ESTABLISHMENT

SECTION DUCTWORK

GREEN INFRASTRUCTURE DESIGNS RAIN GARDEN

GREEN COLLECTION E C O - F R I E N D LY P E R M E A B L E P A V E R S T R E M R O N. C O M

Series casework. 7Storing your world...safely, efficiently, beautifully. C o r p o r a t i o n

ALLEGAN COUNTY ROAD COMMISSION 108TH AVENUE RECONSTRUCTION PROJECT 5,000' EAST OF 15TH STREET TO 6,750' EAST OF 15TH STREET

My Soil Won t Drain, Can I Still Use LID? Rob Buchert, John Knutson, Erik Pruneda

ACTIVITY: Geotextiles ES 12

Portland, Oregon, (population 551,000) endeavors to maintain

The following general requirements will be met for all planter box installations:

Appendices: Glossary. General Terms. Specific Terms. Low Impact Development Approaches Handbook

FOR PROJECTS INITIATED AFTER FEBRUARY 1, 2010 REVISION 1 ITEM 709 TRIANGULAR FILTER FABRIC FENCE

AquaBlox Water Matrix

ENGINEERING DESIGN STANDARDS for CITY OF LAKE ELMO

STORM WATER MANAGEMENT PLAN APPLICATION Manheim Borough

Structural Stormwater Best Management Practices

EnkaTech Note. Installation Guide for Enkamat Slopes and Channels. Site Preparation. Anchor Trench. Enkamat Installation

CHAPTER 9 STORM DRAINAGE. Minimum Requirements for New Development and Redevelopment

Table 4.7.1: Swales Potential Application and Storm Water Regulation

South Fraser Perimeter Road (SFPR)

Guidelines for Earthquake Bracing of Residential Water Heaters

HOME INSPECTION CHECKLIST

Series SFN Unbraided Flexible Hose Assemblies Series SFB Braided Flexible Hose Assemblies

CHAPTER 8 CHIMNEYS AND VENTS

Local Stormwater Retrofit Case Studies. Westmoreland County Conservation District Updated 11/2011

GEOMEMBRANE FIELD INSTALLATION

HYDRAULIC DESIGN involves several basic

A PVC geomembrane integrated in the landscape

plumbing for greywater

CONSTRUCTION DRAWINGS MODULE 6 LINER SYSTEM MONTEREY PENINSULA LANDFILL

SPECIAL SPECIFICATION 3687 Impermeable Liner

Final Report: Appendix G. LID Driveway Retrofit and Teaching Tool at Bristol County Agricultural High School, Dighton - Supporting Information

Letter of Credit Itemized Cost Estimate For: 100% Site Development Costs

UNIFIED FACILITIES GUIDE SPECIFICATION

A. Section Common Motor Requirements for HVAC Equipment: Fan motors.

Technical Assistance Permeable Interlocking Concrete Pavement PICP

GEOSYNTHETICS ENGINEERING: IN THEORY AND PRACTICE

n1. Design 5.4.6a Urban Bioretention 5.4.6a Urban Bioretention Variations: Planter box, Extended tree pits, Stormwater curb extensions.

Scope of accreditation

Curb Inlet Filter INSTALLATION MANUAL. Bio Clean Environmental Services, Inc. 398 Via El Centro Oceanside, CA 92058

Rainwater Management an issue for the 21 st Century. Hydrological Cycle

VALLEY COUNTY MINIMUM STANDARDS FOR PRIVATE ROAD DESIGN AND CONSTRUCTION

GEOSYNTHETICS IN TRANSPORTATION

Low Flow Rates Low Filtration Sandy Soils Medium Flow Rates Medium Filtration Clayey Soils [1] High Flow Rates High Filtration Polluted Soils

Wisconsin Contractors Institute Continuing Education

CHAPTER 8 CHIMNEYS AND VENTS

ENGINEERING DESIGN STANDARDS for CITY OF LAKE ELMO

A. Install all temporary erosion control measures (in accordance with MNDOT General Conditions 2573) prior to site disturbance.

St. Monica Food Pantry

Capillary Action Subsurface Irrigation

SECTION GYPSUM PLASTER

SECTION PLUMBING

STANDARD DETAILS QUICK REFERENCE

Appendix D - Technical Design Criteria for BMPs

Dan, this is a list of the items included in the submittal package for the Plan Commission Public Hearing on May 24, 2018:

BEST LOCAL LAND USE PRACTICES

SUBCOURSE EDITION EN US ARMY ENGINEER SCHOOL PLUMBING FIXTURES (PLUMBING IV)

Drainage Analysis-Newgate/Phelps & Hatchett Hill Road Areas Rev. 0 Erosion & Sediment Control Measures

Te c h S p e c 3. Edge Restraints for Interlocking Concrete Pavements

Citywide Integrated Stormwater Management Plan (ISMP) DRAFT ACTION PLAN REVIEW Public Consultation November 16 th, 2016

SIGN PLACEMENT-ELEVATION VIEW: FREEWAY SIGN PLACEMENT-ELEVATION VIEW: FREEWAY ROADSIDE SIGN LOCATIONS & SUPPORT SPACING NOT TO SCALE

Low Impact Development Practices

DESIGN AND CONSTRUCTION OF A DE-ICING FACILITY FOR A SMALL AIRPORT ENVIRONMENT

Transcription:

NATURAL GROUND WITH SEEPAGE LAYERS AND / OR PERVIOUS SOIL CAP MATERIAL FOR "GRANULAR BLANKET" SHALL BE GRANULAR MATERIAL CLASS II SOD AND TOPSOIL OR TOPSOIL, SEED, AND MULCH AS SPECIFIED ON PLANS CLASSED AS "GRANULAR BLANKET" 1-6" POSSIBLE PERVIOUS SOIL SEEPAGE PLANE PROPOSED POSSIBLE SEEPAGE PLANE DITCH 3-0" (ALTERNATE LOCATION) GRANULAR BLANKET TYPE 1 NATURAL GROUND WITH SEEPAGE LAYERS AND / OR PERVIOUS SOIL CAP MATERIAL FOR "GRANULAR BLANKET" SHALL BE GRANULAR MATERIAL CLASS II SOD AND TOPSOIL OR TOPSOIL SEED, AND MULCH AS CALLED FOR ON PLANS CLASSED AS "GRANULAR BLANKET" POSSIBLE PERVIOUS SOIL SEEPAGE PLANE POSSIBLE SEEPAGE PLANE DRAINAGE LAYER PROPOSED DITCH GRANULAR MATERIAL CLASS II 3" NOMINAL DEPTH 2" LAYER OF OPEN-GRADED AGGREGATE WITH GEOTEXTILE BLANKET ABOVE AND BELOW, OR THREE DIMENSIONAL MESH WITH GEOTEXTILE BLANKET ABOVE AND BELOW, OR OTHER APPROVED GEOCOMPOSITE SECTION GRANULAR MATERIAL CLASS II 12" MINIMUM DEPTH OPTION 1 THE BOTTOM THE PREFABRICATED DRAINAGE GEOCOMPOSITE SHALL BE FLUSH WITH THE SURFACE AT A MINIMUM OF 6" ABOVE DITCH BOTTOM PROPOSED DITCH PROPOSED DITCH 3-0" 6" PREFABRICATED DRAINAGE GEOCOMPOSITE WITH GEOTEXTILE ON BOTH SIDES OPTION 3 OPTION 2 NOTE: OPTION 1, 2, OR 3 WILL BE DETERMINED BY THE ENGINEER BASED ON THE PROJECT CONDITIONS. GRANULAR BLANKET TYPE 2 DEPARTMENT DIRECTOR Kirk T. Steudle Michigan Department of Transportation PREPARED BY DESIGN DIVISION APPROVED BY: DIRECTOR, BUREAU OF FIELD SERVICES DRAWN BY: B.L.T. CHECKED BY: W.K.P. APPROVED BY: DIRECTOR, BUREAU OF HIGHWAY DEVELOPMENT 1 OF 8

A SEEPAGE OUTLET TO BE LOCATED AS DIRECTED BY THE ENGINEER AREA OUTLET TO DITCH OR DRAINAGE STRUCTURE AS DIRECTED BY THE ENGINEER DITCH BOTTOM DRAINAGE MARKER POST SEEPAGE AREA (PIPE SHALL BE WRAPPED WITH GEOTEXTILE) A SOLID PIPE TO BE PAID FOR AS UNDERDRAIN OUTLET (RIGID PVC PIPE OR CORRUGATED STEEL) SECTION A - A OUTLET SEWER - TO BE REMOVED SEWER - TO BE ABANDONED SEWER - TO REMAIN IN SERVICE CAP UNDERDRAIN PIPE WITH A GEOTEXTILE MATERIAL. NOT PAID FOR SEPARATELY, BUT INCLUDED IN UNDERDRAIN OUTLET EXISTING DRAINAGE STRUCTURE 4" SOLID PIPE (RIGID PVC PIPE OR CORRUGATED STEEL) * 6-0" OF 4" TO BE PAID FOR AS UNDERDRAIN OUTLET LENGTH OF BULKHEAD SHALL EQUAL 1/3 DIAMETER OF EXISTING SEWER BUT NOT LESS THAN * WEEPER UNDERDRAIN AND BULKHEADING SEVERED SEWER 2 OF 8

PIPE DIA. + PIPE DIA. EACH SIDE 8", 12" MAX. FOR 4" DIA. PIPE 12", 16" MAX. FOR 6" DIA. PIPE DISTANCE AS DIRECTED BY THE ENGINEER DISTANCE AS DIRECTED BY THE ENGINEER SOD AND TOPSOIL OR TOPSOIL, SEED, AND MULCH AS SPECIFIED ON PLANS. SLOPE AS SPECIFIED ON PLANS GRANULAR MATERIAL CLASS II AA TOP OF SLOPE PERVIOUS SOIL GRANULAR MATERIAL CLASS II AA 6-0" MAX. EXISTING GROUND 6-0" MAX. 3-0" SEEPAGE PLANE TRENCH TO BE PLACED IN SLOPE IF THIS DIMENSION EXCEEDS 6-0" (SEE SLOPE POSITION) (SLOPE POSITION) WITH GEOTEXTILE) S DISTANCE AS DIRECTED BY THE ENGINEER 6" MINIMUM OVERLAP TOP OF SLOPE EXISTING GROUND PERVIOUS SOIL GRANULAR MATERIAL CLASS II 4-0" MAX. SEEPAGE PLANE OPEN-GRADED AGGREGATE 34-R TRENCH SHALL BE LINED WITH GEOTEXTILE BLANKET (PIPE NOT WRAPPED) 1" - 2" PIPE DIA. + PIPE DIA. EACH SIDE 8", 12" MAX. FOR 4" DIA. PIPE 12", 16" MAX. FOR 6" DIA. PIPE, OPEN-GRADED 3 OF 8

4-0" UNLESS OTHERWISE SPECIFIED 6" MINIMUM OVERLAP (DEPTH AS SPECIFIED ON PLANS) SLOPE AS SPECIFIED ON PLANS OPEN-GRADED AGGREGATE 34-R FLOW LINE ELEVATION APPROX. 5-0" DEEP UNLESS OTHERWISE SPECIFIED TRENCH SHALL BE LINED WITH GEOTEXTILE BLANKET UNDERDRAIN (PIPE SHALL NOT BE WRAPPED) 1" - 2" PIPE DIA. + PIPE DIA. EACH SIDE 8", 12" MAX. FOR 4" DIA. PIPE 12", 16" MAX. FOR 6" DIA. PIPE UNDERDRAIN - OPEN-GRADED 4-0" UNLESS OTHERWISE SPECIFIED (DEPTH AS SPECIFIED ON PLANS) SLOPE AS SPECIFIED ON PLANS GRANULAR MATERIAL CLASS II AA FLOW LINE ELEVATION APPROX. 5-0" DEEP UNLESS OTHERWISE SPECIFIED UNDERDRAIN OF LANE WIDTH UNDERDRAIN PIPE DIA. + PIPE DIA. EACH SIDE 8", 12" MAX. FOR 4" DIA. PIPE 12", 16" MAX. FOR 6" DIA. PIPE LONGITUDINAL JOINT LINE CENTER OF TRENCH 3-0" 0R AS SPECIFIED ON PLANS (DEPTH AS SPECIFIED ON PLANS) 2" GRANULAR MATERIAL CLASS II AA WHEN ADDITIONAL UNDERDRAINS ARE REQUIRED, THEY SHALL BE PLACED IN THE CENTER OF A LANE UNDERDRAIN UNDERDRAIN FLOW LINE ELEVATION NORMALLY A MAXIMUM OF 10" BELOW TOP OF OR AS SPECIFIED ON PLANS PIPE DIA. + PIPE DIA. EACH SIDE 8", 12" MAX. FOR 4" DIA. PIPE 12", 16" MAX. FOR 6" DIA. PIPE 4 OF 8

FOR HMA S GREATER THAN 4-0" IN WIDTH. OTHERWISE, CONTINUE OPEN- GRADED DRAINAGE COURSE AS SHOWN ON THE PLANS. (CRUSHED CONCRETE WILL NOT BE ALLOWED AS A DENSE GRADED AGGREGATE UNDER THE ) 3-0" OF LANE WIDTH TRENCH SHALL LONGITUDINAL JOINT LINE CENTER OF TRENCH GEOTEXTILE SEPARATOR BE LINED WITH GEOTEXTILE BLANKET 2" WHEN ADDITIONAL OPEN-GRADED UNDERDRAINS ARE REQUIRED, THEY SHALL BE PLACED IN THE CENTER OF A LANE. OPEN-GRADED DRAINAGE COURSE, 6" IN PLACE 1" - 2" OPEN-GRADED AGGREGATE 34-R, BACKFILL 2" - 3" ABOVE TOP OF TO COVER 6" LATERAL PORTION OF GEOTEXTILE BLANKET THAT LINES THE TRENCH * OPEN-GRADED UNDERDRAIN PIPE * THE OPEN-GRADED UNDERDRAIN PIPE SHALL NOT BE WRAPPED WITH GEOTEXTILE. PIPE DIA. + PIPE DIA. EACH SIDE 8", 12" MAX. FOR 4" DIA. PIPE 12", 16" MAX. FOR 6" DIA. PIPE OPEN-GRADED UNDERDRAIN PIPE WITH GEOTEXTILE SEPARATOR FOR HMA S GREATER THAN 4-0" IN WIDTH. OTHERWISE, CONTINUE OPEN- GRADED DRAINAGE COURSE AS SHOWN ON THE PLANS. (CRUSHED CONCRETE WILL NOT BE ALLOWED AS A DENSE GRADED AGGREGATE UNDER THE ) 3-0" OF LANE WIDTH TRENCH SHALL LONGITUDINAL JOINT LINE CENTER OF TRENCH SEPARATOR COURSE BE LINED WITH GEOTEXTILE BLANKET 2" WHEN ADDITIONAL OPEN-GRADED UNDERDRAINS ARE REQUIRED, THEY SHALL BE PLACED IN THE CENTER OF A LANE. OPEN-GRADED DRAINAGE COURSE, 6" IN PLACE OPEN-GRADED AGGREGATE 34-R, BACKFILL 2" - 3" ABOVE TOP OF / AGGREGATE SEPARATOR TO COVER 6" LATERAL PORTION OF GEOTEXTILE 1"- 2" BLANKET THAT LINES THE TRENCH * OPEN-GRADED UNDERDRAIN PIPE PIPE DIA. + PIPE DIA. EACH SIDE 8", 12" MAX. FOR 4" DIA. PIPE 12", 16" MAX. FOR 6" DIA. PIPE * THE OPEN-GRADED UNDERDRAIN PIPE SHALL NOT BE WRAPPED WITH GEOTEXTILE. OPEN-GRADED UNDERDRAIN PIPE WITH SEPARATOR COURSE 5 OF 8

FOR HMA S GREATER THAN 4-0" IN WIDTH. OTHERWISE, CONTINUE OPEN- GRADED DRAINAGE COURSE AS SHOWN ON THE PLANS. (CRUSHED CONCRETE WILL NOT BE ALLOWED AS A DENSE GRADED AGGREGATE UNDER THE ) GEOTEXTILE SEPARATOR 2" 2 " MAX. OPEN-GRADED DRAINAGE COURSE, 6" IN PLACE WHEN ADDITIONAL OPEN-GRADED UNDERDRAINS ARE REQUIRED, THEY SHALL BE PLACED IN THE CENTER OF A LANE. 2" * 3" - 6" MAX. TRENCH WIDTH * OPEN-GRADED AGGREGATE 34-R, BACKFILL 2" - 3" ABOVE TOP OF TO COVER 6" LATERAL PORTION OF GEOTEXTILE SEPARATOR AND TO PROTECT THE PDS FILTER COVER OPEN-GRADED UNDERDRAIN ( PDS ) WITH GEOTEXTILE SEPARATOR FOR HMA S GREATER THAN 4-0" IN WIDTH. OTHERWISE, CONTINUE OPEN- GRADED DRAINAGE COURSE AS SHOWN ON THE PLANS. (CRUSHED CONCRETE WILL NOT BE ALLOWED AS A DENSE GRADED AGGREGATE UNDER THE ) SEPARATOR COURSE 2" 2 " MAX. OPEN-GRADED DRAINAGE COURSE, 6" IN PLACE WHEN ADDITIONAL OPEN-GRADED UNDERDRAINS ARE REQUIRED, THEY SHALL BE PLACED IN THE CENTER OF A LANE. 2" * 3" - 6" MAX. TRENCH WIDTH * OPEN-GRADED AGGREGATE 34-R, BACKFILL 2" - 3" ABOVE TOP OF TO PROTECT THE PDS FILTER COVER OPEN-GRADED UNDERDRAIN ( PDS ) WITH SEPARATOR COURSE 6 OF 8

BEND 5-0" LENGTH OF UNDERDRAIN PIPE TO A 90 ARC. CONNECTION SHALL BE ACCORDING TO THE CURRENT SPECIFICATIONS OR AS APPROVED BY THE ENGINEER. END CAP SAG UNDERDRAIN OUTLET PIPE (RIGID PVC OR CORRUGATED STEEL) OUTLET ENDING 1 SYD SOD UNDERDRAIN OUTLET PIPE (RIGID PVC OR CORRUGATED STEEL) DISTANCE AS REQUIRED. BACKFILL TRENCH WITH GRANULAR MATERIAL CLASS II AA. MAXIMUM OUTLET SPACING 300 ADDITIONALLY, LOCATE OUTLETS AT THE ( LOWEST ELEVATION OF ALL VERTICAL CURVES ) PLAN SHOWING OUTLETS FOR UNDERDRAINS " x 1" x 2" STEEL FOR CONNECTOR BRACKET " X 2" GALVANIZED BOLT AND NUT " \ " " DIA. GALV. ROD DIA. HOLE " 1" REINFORCED EDGE 1" LIMITS OF UNDERDRAIN OUTLET REINFORCED EDGE DETAIL CONNECTOR BRACKET DETAIL RODENT SCREEN 4" 6" MAX. METAL END SECTION CORNER PLATES TO BE TIGHTLY SECURED USING " GALVANIZED RIVETS, BOLTS, OR EQUIVALENT SPOT WELDS PIPE DIA. 3" SKIRT LIP 3" x 5" CORNER PLATE C.M.P. 9" 4" 4" 1-8" STEEL END SECTION FOR 4" OR 6" PIPE 7 OF 8

LIMITS OF UNDERDRAIN OUTLET 3-0" 4" 3" 6" MAX. OUTLET PIPE " RADIUS 45 PIPE DIA. APPROVED CONNECTION COMPATIBLE WITH PIPE 45 4" RODENT SCREEN SOD CONCRETE RING FOR 4" OR 6" PIPE LIMITS OF UNDERDRAIN OUTLET 10" OUTLET PIPE 4" 6" MAX. NOTES: POSITIVE DRAINAGE SHALL BE PROVIDED FOR UNDERDRAINS AND UNDERDRAIN 11" OUTLETS. 4" UNDERDRAIN PIPE SIZES SHALL BE AS SPECIFIED ON THE PLANS. 2" WALL THICKNESS RODENT SCREEN APPROVED CONNECTION COMPATIBLE WITH PIPE CONCRETE END SECTION FOR 4" OR 6" PIPE CONNECTIONS BETWEEN UNDERDRAIN PIPE AND UNDERDRAIN OUTLET PIPE SHALL BE CONSTRUCTED ACCORDING TO THE CURRENT STANDARD SPECIFICATIONS AND AS APPROVED BY THE ENGINEER. CONNECTIONS, IF REQUIRED WITHIN THE OUTLET PIPE, SHALL BE ACCORDING TO APPLICABLE ASTM SPECIFICATIONS REFERENCED IN THE CURRENT STANDARD SPECIFICATIONS. THEY SHALL BE WATER TIGHT, AND OF THE SAME MATERIAL AS THE OUTLET PIPE. OUTLET CONNECTIONS TO DRAINAGE STRUCTURES SHALL BE ACCORDING TO CURRENT STANDARD SPECIFICATIONS FOR DRAINAGE STRUCTURES. UNDERDRAIN OUTLET PIPE SHALL BE RIGID PVC OR CORRUGATED METAL ONLY. INSIDE PIPE DIA. + 3" THE CONCRETE RING OR CONCRETE END SECTION SHALL BE CAST AROUND THE SAME TYPE OF PIPE AS THAT USED FOR UNDERDRAIN OUTLET PIPE. STEEL END SECTIONS SHALL BE ATTACHED TO THE ENDS OF CORRUGATED METAL PIPE AS SPECIFIED ON THIS STANDARD PLAN, BY STANDARD METAL BANDS, OR BY OTHER CONNECTING DEVICES AS APPROVED BY THE ENGINEER. 0.30" MAX. OPENING INSIDE PIPE DIA. + 1" STEEL END SECTIONS MAY ALSO BE ATTACHED TO THE ENDS OF PVC OUTLET PIPE AS APPROVED BY THE ENGINEER BY USING A PVC ADAPTER THAT PROVIDES SIMILAR RESISTANCE TO MOVEMENT OF THE CONNECTION DEVICE AS THAT PROVIDED BY STEEL PIPE CORRUGATIONS. DIRECT ATTACHMENT OF THE STEEL END SECTION TO END OF STANDARD PVC OUTLET PIPE IS NOT ACCEPTABLE. HELICALLY CORRUGATED PIPE (EXCEPT PERFORATED PIPE) SHALL HAVE THE ENDS OF THE PIPE REROLLED TO FORM ANNULAR CORRUGATIONS FOR CONNECTING THE END SECTION. 0.057" DIA. NOMINAL WIRE RODENT SCREEN 8 OF 8