L24TWS. Beverage Tower Kit Components. L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

Similar documents
USE/INSTALLATION INSTRUCTIONS VRBD/VUBD 24 W. BEVERAGE DISPENSER

Viking Use/Installation Guide

(rev. 10/04/12)

INSTALLATION AND OPERATION INSTRUCTIONS CONCESSIONAIRE PORTABLE DISPENSERS MODEL NOS.

Household Beverage Cooler

SAFETY PRECAUTIONS Read all of the instructions before using this appliance. When using this appliance, always exercise basic safely precautions,

(rev. 07/01/14)

SBC490Bi(All Versions) UNDER-COUNTER FULLSIZE BEER DISPENSER

Instruction Manual BEER DISPENSER ABDA049AS

4.9 CU.FT. BEER KEG COOLER INSTRUCTION MANUAL. Model No.: MCKC490S

BR3001SS BR3001BL 5.6 CU.FT.

INSTALLATION and OPERATION INSTRUCTIONS

Beer Keg Dispenser User s Manual

OPERATION MANUAL.

SuperKlean Washdown Products

DIRECT DRAW BEER COOLERS Installation, Operation and Maintenance Instructions

FULL-SIZE UNDER-COUNTER BEER DISPENSER

PrimePour TM Operation Manual

Getz Equipment Innovators 450 lb Dual Portable Dry Chemical Fill System

Installing the Turbo Floor Model System

INSTALLATION INSTRUCTIONS

APEX Water Filters MODEL RO 5. Treat your body to pure goodness with Apex filtered water INSTRUCTION MANUAL. pure water in every drop

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Outdoor Unit UQB09JJWC UQB12JJWC. Indoor Unit AQB09JJWC AQB12JJWC

UDD1, UDD1S, UDD2448, UDD2448S, UDD2460, UDD2460S, UDD2472, UDD2472S

TRAINING OUTLINE POST-MIX DAILY MAINTENANCE

Handshower, Hose & Handshower Accessories

Drinking Water Purification Systems

INSTALLATION & OPERATING INSTRUCTIONS MODEL #17900 KEGERATOR MANUAL

Installation Manual UNDER COUNTER GYLCOL REMOTE COOLING UNIT

BMW E36 Thermostat Removal And Coolant Flush

COMMERCIAL GRADE UNDER COUNTER REFRIGERATION RANGE

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

Dual Beer Kegerator/Beverage Cooler

Installation Manual UNIVERSAL C-750 PRE-MIX DISPENSER

- 1 - Updated on 18 March, 2010

OPERATION MANUAL VCX-4 Vacuum Coolant Exchanger

BOTTLED WATER DISPENSER DISPENSADOR DE AGUA EMBOTELLADA

Alkaline RO System INSTALLATION MANUAL

- 1 - Updated on 18 March, 2010

Unpacking and removing shipping bolts. Connecting the drain line Leveling the washer Connecting to the power supply

TABLE OF CONTENTS FOR YOUR SAFETY

INSTALLATION MANUAL. Split-type Air Conditioner (Cooling and Heating) Indoor Unit AQB18J6WC AQB24J2WC. Outdoor Unit UQB18J6WC UQB24J2WC

Removing shipping locks

Installation Instructions

Installation Instructions Built-In Dishwasher

Installation & Operating Guide

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Pony-Size Kegerator VT-PONYKEG

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Operation & Installation Manual

A PROUD HERITAGE OF EXPERIENCE & QUALITY. Full-Size Kegerator VT-FULLKEG

Assembly- and Usermanual. Rainmaker. Code No GB. Edition: 09/2007

Built-In Dishwasher. Installation Instructions. BEFORE YOU BEGIN Read these instructions completely and carefully. IMPORTANT The dishwasher MUST be

20 TON AIR/MANUAL SHOP PRESS

SERVICE/INSTALLATION MANUAL ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250

Instant Hot Water Dispenser Owner s Manual

Dishwasher Installation Instructions DW 24XT/DW 24XV

Top Control Dishwasher

Parts & Material Included

5000 Series Bottled Water System by.

Installation Instructions

Installation Instructions for P/N: Algas-SDI thermostat retrofit kit

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

100% Safety Shutoff Control 40,000 BTUH Input Rating Constant Pilot Propane Gas

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation/Service Manual SENTRY III-A GLYCOL COOLING UNIT (R-134A REFRIGERANT)

Installation Instructions

Installation Guide BUILT-IN SXS REFRIGERATOR UPSXB2627**

Installation Instructions

Installation Instructions for. OmniFount

en-us Use and Care Manual, Installation Instructions Washer WAT28400UC

ICE/BEVERAGE DISPENSER

INSTALLATION INSTRUCTIONS

SERVICE MANUAL BEVERAGE CENTER II

TANKLESS REVERSE OSMOSIS SYSTEMS USER S MANUAL

Installation Instructions

OWNER S MANUAL. Models: Herkules Equipment Corporation 2760 Ridgeway Court Walled Lake, MI USA Fax

INSTALLATION. Glass Panel Doors (select models) CAUTION

Installation Instructions Built-In Dishwasher

SAFETY PRECAUTIONS. 2) Before operating machine: - Make sure all safety devices are in place and operate properly.

TROUBLESHOOTING VANGUARD

INSTALLATION INSTRUCTIONS

General System Layout Sketch

4 TON HYDRAULIC FLOOR PRESS INSTRUCTION MANUEL

Models: GW/R-T GW/R-2-T GW/R-3-T

SKY Stainless Steel Compact Dishwasher. Instructions

INSTALLATION INSTRUCTIONS

L A signature series TA T N E RE O, A L L A T S IN

MacDonald Steel Limited

NATURAL GAS CONVERSION KIT

Page 1 of 18. Part# /5/2013

SuperKlean Washdown Products

HX Field Replacement Kit

Electrical cable Water supply tube Fittings for tube Coupler Teflon tape. Hole saw min. 2½" bit

Heat Exchanger Block Replacement Instructions

Owner s Manual. Keep with machine for reference PKC24 INSTALLATION & OPERATION REV Perlick Corporation 8300 W Good Hope Rd Milwaukee, WI 53223

INSTRUCTION MANUAL UNDERCOUNTER BUILT-IN KEGERATOR MODEL:VK1501

As part of the V.I.P. family, you are entitled to the best protection by one of the most comprehensive warranties in the industry.

ICE ONLY DISPENSERS MODELS-IOD150, IOD200 AND IOD250 INSTALLATION/SERVICE MANUAL

Transcription:

Installation, Care and Use of Your Lynx Beverage Tower Kits MOM FRIENDLY. DAD READY. L24TWS Beverage Tower Kit Components L24TWD Lynx Beverage Kits Model L24TWS Single Tower and L24TWD Double Tower

Introduction: Your Lynx Beverage Kits comes with all of the components necessary to install a keg tap and tray to an outdoor island or to the Lynx model L24BF or LM24BF outdoor refrigerators. The Lynx model L24BF and LM24BF outdoor refrigerators have been designed specifically to work with the Beverage Kits. The L24BF refrigerator cavity is designed to accommodate two /6 kegs, or all single standard keg sizes except a ½ keg or larger (not provided), the CO 2 tank and required connections. The LM24BF refrigerator cavity is designed to accommodate all single standard keg sizes (not provided), the CO 2 tank and required connections. Please note in some cases you may need to use sealing gum to seal around the opening at the top of the refrigerator. Warning: CO 2 cylinders contain high pressure gas which can be hazardous if not handled properly. Make sure you READ and UNDERSTAND the procedures regarding the CO 2 cylinders BEFORE installation. Safety First: How to install a CO 2 Regulator or replace an Empty CO 2 Cylinder D B E A. To shut off gas pressure to dispenser always close cylinder valve A 2. Shut off outlet fitting C if regulator is equipped with one. 3. Back out (counterclockwise) regulator adjusting screw B as far out as it will go. (The regulator is now in the off position). 4. Remove regulator from empty cylinder at E. 5. Remove dust cap from new cylinder at E. Open and close valve A quickly to blow dust from outlet. 6. With cylinder valve A in closed position, re-attach regulator to cylinder a E. Use a plastic or fiber CO 2 washer to couple regulator to cylinder. 7. Open valve A all the way. (This is important because this cylinder valve seals in two places). 8. Make certain outlet is closed at C. 9. Turn regulator adjusting screw B in (clockwise) until required pressure is reached D. 0. Open outlet valve C. C CO 2 Safety Device A CO 2 cylinder contains extremely high pressure regardless of size, and therefore should be handled with care!

WARNING CO2 GAS CAN BE DANGEROUS CO 2 Regulator Co2 cylinders contain high pressure gas which can be hazardous if not handled properly. Make sure you READ and UNDERSTAND the following procedures for CO 2 cylinders BEFORE installation.. ALWAYS connect the CO 2 cylinder to a regulator. Failure to do so could result in an explosion with possible death or injury when the cylinder valve is opened. 2. NEVER connect the CO 2 cylinder directly to the product container. Doing so will result in an explosion causing possible death or injury. 3. ALWAYS follow correct procedures when cylinders are changed. 4. ALWAYS secure the cylinder in an upright position with a chain. 5. NEVER drop or throw a CO 2 cylinder. 6. ALWA YS keep a CO 2 cylinder away from heat. Store extra cylinders in a cool place (preferably 70 F). Securely fasten with a chain in an upright position when storing. NEVER place cylinders in direct sunlight or where temperature could rise above 30 F. 7. ALWAYS ventilate and leave the area immediately if CO 2 gas leakage has occurred. NEVER enter a closed area where leakage may have occurred without making certain it has been ventilated. 8. ALWAYS check the D.O.T. test date on the cylinder neck before installation. If over five (5) years. do no use, return cylinder to gas supplier. 9. NEVER connect a product container unless there are two (2) safeties in the pressure system : (a) one at or on the CO 2 regulator (b) one at or on the product coupler or in the pressure gas line. 0. CO 2 Regulators are delicate instruments and should be checked constantly for creeping, sluggishness, damaged gauges, or any unusual behavior. If any of these symptoms occur discontinue use immediately and return regulator to supplier or manufacturer. CAUTION: Failure to connect the regulator by properly following these instructions may result in leaks explosions, asphyxiation and cause serious personal injury or death.

Beverage Tower Kit Components F A H G B I D C E A. Single or Double Keg Tower B. Low Profile Keg Coupler (D System for North American Beers) C. Regulator, Dual Gauge CO 2 D. CO 2 Gas Cylinder E. Spill Tray F. Insulating Sleeve G. Gasket H. Tap Handle I. Faucet Wrench (Kit contains all hoses and fittings, sleeve connectors, bushing and insulator sleeves) Part No. Description Qty Part No. Description Qty 3243 33845 2 804 Tower Assembly Single Tap, or Tower Assembly Double Tap 9 32404 Beverage Center Deck Assembly 0 33029 33847 CO 2 Cylinder, 5 Pounds, Alum Regulator, Single Tap, CO2, or Regulator Double Tap, CO2 3 3244 Tubing, 7/8 OD, x 2 32403 Keg Coupler, Domestic (Style D) 4 32399 5 3242 Insulation, Tower Armaflex Tower Base Leveling Feet 2 33027 4 3 33028 Hose, CO 2 to Coupler Hose Clamps, CO 2 6 3300 Base, Spill Tray Insert 4 33022 Hose, Coupler to Tower 7 330 8 3303 Grate, Spill Tray Insert Faucet Wrench 5 33023 Hose Clamps, Tower 2

L24TWS Tower Kit - Mounting your kit directly to an island.. Determine the location of the refrigerator in the island installation. It should be positioned nearly flush to the face surface of the island for easy access and alignment with the tower. For the refrigerator cavity height and depth, please refer to the cutout for your individual model (L24BF/LM24BF). 2. Position the refrigerator in the island opening at the exact position. Open the door and make a reference mark on the underside of the countertop at the face of the open refrigerator. This surface represents the best guide for locating the hole in the countertop. Each refrigerator door is custom set at the factory for the best seal. The face of the closed door varies slightly from unit to unit. DO NOT use the closed door surface as a reference. 3. Remove the refrigerator from the cabinet while drilling the holes for mounting. Using the diagram at the bottom of this page as a guide, mark the center of a 2 diameter hole and drill through the countertop for the beverage line. 4. Locate and drill the 4 mounting holes to secure the keg tower.* Four #2 screws have been provided. A ¼ diameter hole is sufficient for these bolts. If another securement method (i.e. lead anchors) are used, follow the manufacturers recommendations. 5. A flush mount drip tray is provided as an option. Refer to the diagram below and cut the opening required if this option is to be installed. 6. Prepare the tower assembly for installation. A 4 inch length of insulating foam has been provided to install inside the tower base. The installation of this foam is critical to the proper operation of the beverage tower kit. Failure to properly insulate the tower base could cause excessive foam and incorrect temperature control. Insert the foam around the beverage line and insert it into the beverage tower with about 2 protruding from the base. 7. Place the large flat rubber gasket over the hole in the countertop. 8. Feed the beverage tube into the hole in the countertop 9. Align the gasket and secure the tower to the countertop with the 4 screws provided. From the underside insert the washers and nuts. Tighten the screws completely. 0. Remove the black plastic plug from the top center of the refrigerator. Keep in a safe place for future use.. Bring the beverage tube out to the front of the opening designed for the refrigerator. Begin to slide the refrigerator into the opening. Before the refrigerator is halfway into position, feed the beverage tube through the hole in the top. Alternately slide the refrigerator back and draw the tube into the refrigerator to remove any kinks in the hose. When finished, the hose should align like the illustration on the right. 2. Add the tap and handle with the wrench provided. 3. Insert the spill tray into the countertop. * Before drilling mounting holes, position the tower on the counter top to ensure proper tap alignment. Holes may be drilled out to ½ to provide additional adjustment. LYNX MODEL LM24BF OUTDOOR REFRIGERATOR (UNDER ISLAND COUNTER TOP)

Connecting the Keg to the Beverage Tower.. Attach the clear hose from the beverage tower to the barbed fitting with the hose clamp provided. Insert the rubber washer provided into the fitting. 2. An elbow is included to provide additional space above the keg coupler. Secure the elbow to the top outlet of the keg coupler with a washer between. Attach the clear hose fitting, with washer, to the elbow. Use a wrench to tighten the connections. 3. The colored hose line is installed onto the side barbed fitting of the keg coupler and the barbed fitting below the CO 2 regulator. Press the tube onto the fittings and secure with the two hose clamps. Refer to the instructions provided with the CO 2 tank before attaching the tank to the regulator. 4. With the regulator and tank in the OFF position, attach the regulator securely to the CO 2 tank with a wrench. Use supplied hose clamps here The Kit is Ready to Attach a Keg. The Beverage Tower Kit is provided with a standard D Style coupler. This style is appropriate for most domestic beers. Additional styles are available from restaurant supply or beverage companies.. Align lug locks on coupler with lug housing in top of keg; insert coupler. Operating the Beverage Tap: 2. Turn coupler ¼ turn clockwise; the coupler is now secured to keg. 3. Push down on the coupler and give another ¼ turn, to open beer and CO 2 ports in keg. The keg is now tapped.. Insert the CO2 canister in the rear left shelf inside the refrigerator. CO 2 Tank Level 2. Place the beer keg inside the refrigerator and arrange all hoses such that none are pinched. Main Valve 3. Slowly open the main valve on the CO2 canister. Check for leaks. 8-4 PSI 4. Slowly open the regulator ball valve to pressurize the keg. 5. Toggle the tap handle on the tower to dispense a small amount of liquid. This will charge the system. 6. Adjust the T-handle on the regulator to between 8 and 4 PSI. The pressure setting will vary for Ball Valve beer type and keg style. Refer to the troubleshooting guide and experimentation to set the pressure T-Handle accordingly. 7. Allow the system to rest for several hours before use. Temperature and pressure are critical to satisfactory results.

When not in use: We recommend that the CO2 canister be shutoff and the ball valve closed if the Beverage kit will not be used for an extended period of time. Keep the CO2 tank inside the refrigerator and all connections intact. The CO2 tank should be replaced or refilled when the CO2 Tank level indicator falls into the red indicator zone (below 300 PSI). Check with your beverage provider for local sources of CO2. Storage: For seasonal storage of the Beverage Kit we recommend that the CO2 tank be stored upright in a cool place. The Tower Base may be disconnected from the keg coupler and removed from the island installation. To help prevent heat loss replace the black plastic cap into the top of the refrigerator (see page 2 step ). The cap may be installed into the top or from the inside if more convenient. Seal all hoses and connectors in an air tight plastic bag to avoid dirt and insects during storage. We recommend that you obtain a cleaning kit and purge the fluid lines seasonally. These may be obtained from your beverage supplier or on line. Wild Beer Description Beer, when drawn, is all foam, or too much foam and not enough liquid beer. Beer drawn improperly Creeping regulator Applied pressure is set too high Hot spots in line Use of non-insulated beer line Beer runs are too long for proper cooling Tapped into a warm keg (Should be 34-38 Cooler malfunctioning Kinks, dents, twists or other obstructions in line Faucets in bad, dirty or worn condition Flat Beer Description Foamy head disappears quickly; beer lacks usual zestful brewery fresh flavor Dirty glasses (not beer clean) Sluggish regulator Applied pressure is set too low CO 2 is turned off at night Contaminated air source (associated with compressed air) Moisture in air system Beer too cold Loose tap or vent connections Cloudy Beer Description When beer in glass appears hazy, not clear Frozen or nearly frozen beer Old beer Beer that has been unrefrigerated for long periods of time Dirty glass Dirty faucet Unrefrigerated foods placed on top of cold keg Contaminated air source False Head Description Large soap-like bubbles, head dissolves very quickly Applied pressure required does not correspond to beer temperature Small beer line into a large faucet shank Beer lines warmer than beer in keg Dry glasses Improper pour Unpalatable Beer Description Off-Taste Dirty or old beer lines Dirty faucet Contaminated air source, or unfiltered Unsanitary bar conditions Lynx Professional Grills, Inc. 7300 Flores St., Downey, CA 90242 Phone: (888)289-5969 Fax: (562)299 6978 www.lynxgrills.com P/N 3393 Rev. E 8/7

The best outdoor kitchen products come from: Lynx Grills, Inc. 7300 Flores Street Downey, CA 90242 For more information, please call: -888-289-5969 or visit www.lynxgrills.com Email us at service@lynxgrills.com As product improvement is an ongoing process at Lynx, we reserve the right to change specifications and design without notice. Part #3393, Rev. E 8/7