THERMAL MANAGEMENT. Outdoor 3.13 to

Similar documents
Flexible and efficient: Close Climate Control for IT equipment

ClimaSys Resistance heaters Selection guide

Medical Refrigerators

BIOMEDICAL FREEZERS ULTRA LOW TEMPERATURE FREEZERS LOW TEMPERATURE FREEZERS

Innova M4, M5 and M5-ISo

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

HEATING. Anticondensation Heaters

Technical Description. Laboratory Climate Test Chamber. System Weiss. Mat. No.: Type WKL 34/40

VEROTEC Electronics Packaging

ULTRA LOW TEMPERATURE FREEZERS, -86ºC Upright & chest freezers

HEAT TRANSFER ANALYSIS OF 1-USER SERVER THROUGH CFD

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Cooling unit Mechanical control

Heating THERMAL MANAGEMENT SOLUTIONS FOR ELECTRICAL ENCLOSURES

SEALED ENCLOSURE COOLING

PR / MP I Laboratory / Medicine

Eldon Product Overview

Outdoor Enclosures. Outdoor Enclosures Protected like a bunker for all harsh environments

Content. Heating. Ventilating. Regulating and Monitoring. Lighting. Accessories

BIOMEDICAL REFRIGERATORS

SmartShelter Room. Technical Description. Version 1.1 Jul. 2017

Innova new M2 and M3 series

TPF Series Ozone Generators

Technical Description. Climate Test Cabinet with increased change rates. Stress Screening System Weiss. Mat. No.: Type

Ultra Deep Freezers -86 C. Biomedical Refrigeration I UF. Technology for life _8pages_dometic_UF.indd 1 10/09/08 11:17:32

STABILITY ICH. ICH Stability Tests

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

stego_katalog_2008_en.qxp:englisch :09 Uhr Seite 1 Product Catalogue

BR range. B Medical Systems BR I +4 C. Blood Bank Refrigerators

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Deep Freezers. Freezers. Biomedical Refrigeration I FR / MF

Fan-and-filter units 4.3. Features. Fast assembly. Application diversity and functions

DEEP FREEZERS AND PLASMA STORAGE FREEZERS. Biomedical Refrigeration I FR / MF TECHNOLOGY FOR LIFE

LR range (solid door) LR 750 G / GG

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Knürr RMS Compact II. Knürr RMS Compact II 2.81

Extreme industrial environments Air/water heat exchangers (roof-mounted, wall-mounted) Recooling system

Ultra Low Freezers. Blood Management Solutions. B Medical Systems U Range

SITE CONDITIONS Design Altitude < 3,280 Ambient Temperature F Humidity < 80 % Gas and Noxious Vapors

INTRODUCTION. JAU /JCC/JVC Series Jet Fans - for car park ventilation

Rieger. Industrievertretungen GmbH. Vertrieb durch: Ihr Anbieter für Geräte im Bereich Labor, Mikrobiologie und Industrie. Wir sind für Sie da:

BIOMEDICAL FREEZERS ULTRA LOW FREEZERS - LABORATORY, PHARMACEUTICAL AND MEDICAL REFRIGERATION

STABILITY. Stability Storage Chambers & Environmental Stability Rooms

FITOCLIMA 600 & 1200 STABILITY

HOW TO REDUCE ENERGY CONSUMPTION OF BUILT-IN REFRIGERATORS?

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

More Precision. thicknesssensor // The sensor for precise thickness measurements

Ultra-Thin Flexible Heaters

FITOCLIMA ECV45 / ECV75 TEMPERATURE & HUMIDITY TEST CHAMBER INTEGRATION WITH ELECTRO-DYNAMIC SHAKER

Vapor Condensers Schwakos

Refrigerant air dryers. FD series ( l/s, cfm)

IQ8Control C Fire Alarm Panel

Platelet bags constant shaking for long periods of time.

Multi-Lab REFRIGERATORS Frigidere medicale

VMA-VMB NOVA AIR HEATERS. NoVa air heaters

Level gauges Series LS Level indicator, switch and transmitter for liquids

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Model MKFT 115 Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

pyxis pyxisa NEW rcgroupairconditioning

More Precision. indusensor // Linear inductive displacement sensors

Your competent partner for measuring and services.

Refrigeration dryers with Energy Saving Impulse Technology and Thermal Mass 0,3-27,0 m³/min Purifying your compressed air, increasing your efficiency.

Advantages / Characteristics

Optiline Fan Array. The optimum number of fans for every application. The Optimum in Sound Energy Size Redundancy Reliability.

Rittal roof-mounted fans Efficiency on top

Everyone talks about the future, but Rittal helps shape it and that includes. Modern cooling units with excellent efficiency and perfect interface

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

Heating Mats and Jackets. innovations in heat tracing

Air cooled chillers. Air cooled chillers with brushless oil-free compressors. RAC. Ka Series - 1 or 2 cooling circuits capacity from 300 to 1400 kw

pyxis hp "u" pyxis hp "u" IDEA NEW rcgroupairconditioning

Energy saving refrigeration dryers SCFM. Purifying your compressed air, increasing your efficiency.

Laboratory Freezers. Medical Refrigeration. B Medical Systems F Range

VD 53 - Vacuum drying oven for non-flammable solvents

Basic Input Data Needed to Develop a High Performance Fan/Blower with Low Noise, Energy Saving and High Efficiency

Bionics Instrument. Alarm Handling. Gas Alarm Systems

pyxis cla pyxis cla A-CLASS NEW rcgroupairconditioning

Product Description. Options. Fan Voltage. Electrical Connections Technical Data - Key Characteristics

UV Flame Supervision System

Cooling and heating systems. Static cooling ceiling system SKS-5/3 for visible installation

E-Wheel Backward Curved Centrifugal Fans

AUTOMOTIVE SOLUTIONS RELIABILITY SUSTAINABILITY COMFORT

edition version 1.1 Green ICE KW Antibacteria

Stego accessories for cabinets

Process Alarm Module RTA 421

Powerful and reliable. Also for high ambient temperatures. weco Compact chillers

Protection, safety, reliability. And more.

Blood Bank Refrigerators

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

Conveyor and Batch Reflow Ovens

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

TrueAlarm Analog Sensing

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

AGRICULTURE AND FORESTRY CONSTRUCTION AND MINING AUTOMOTIVE, COMMERCIAL VEHICLES AND RAILWAYS INDUSTRIAL EQUIPMENT

Technical data sheet. Lyovapor L-300

Dräger Polytron 8000 Stationary gas detector (EC)

QUANTURA DISHWASH DOSING SYSTEMS. revolutionary dispensing solutions

inorax Outdoor Enclosures

Transcription:

Tecoras Outdoor.1 to.18.15

Tecoras Thermal Management Strong points TEC00087 The permanent increase ofheat dissipation in electronic components and the higher packaging density of the equipment caused special requirements for thermal management in our enclosures. Knürr established aclimate competence center to propose our customer the best solutions in thermal management. 1 Modularity - Adjustment to various temperature conditions through the mechanical and electrical compatibility of heat exchangers and cooling devices - Interface for alarm monitoring and external sensors 2 Complete Product Range Complete product range ist the best condition to to fulfill all customer specification - K-HEX, Knürr Heat Exchanger - HEC, Heat Exchanger Cabinet - ACUR, Air Conditioning Unit - Filter Fan - Heater - Controller Board - Membrane Filter Climatic chamber - Inter size:,0x,0x,0 m - Door size: 1,15x2,45 m 2 - Temperature -45... +60 C range: - Humidity range: 10... 95% (at 10... 40 C) - Access for forklift truck 1 TEC00006 TEC00279 4 Measurement instruments/ documentation Data logger up to 80 chanels: - Temperature - Voltage - Current - Revolutions Measurement instruments: - Relative humidity - Velocity - Pressure Data export in all usually formats 4 TEC20081.16

Tecoras Thermal Management Strong points 5 Thermal design/cfd Knürr used several calculation tool to design the right thermal sotution. The most powerful software is the Computational Fluid Dynamics (CFD) program to calculate temperature profiles and air flow velocities before prototyping. As a service Knürr offers simulation reports and designed the thermal solution exact according the specification. 6 Smoke Text Smoke visualize air flow. 5 TEC20080 6 TEC20072 Zones with low air flow become visible. These zones have risks of hot spot. To avoid hot spots a modification of the configuration are proposed. 7 Acoustic noise emission In house semi-anchoic test floor 7 TEC2007 Acoustic-Measurement of airborne noice according ISO 7779 Thermal chamber and acoustic test floor are next to each other. Knürr adjust the contrary specification requirements of low airborne noise and high cooling performance on an optimum way. 8 TEC80001 8 Acoustic noise absorber Knürr cabinets achieve very low levels of airborne noise emission. Knürr used special designed noise absorber for low aoustic noise cabinets. This allows to operate cabinets in areas with special aoustic noise limits..17

Tecoras Air-to-air heat exchanger (K-HEX) TEC20062 High-capacity, compact air-to-air heat exchanger for door installation in TECORAS outdoor cabinets Degree of protection - IP 55 Approvals - CE - UL approval - EN 60 950 Principle - Air-to-air heat exchanger with freely programmable micro processor control - Countercurrent heat exchanger of epoxy coated aluminium with extruded surface - Direct mounting on the inside of the door, Identical mounting principle and uniform screwing conditions for all thermal components - IP 55 interface between heat exchanger and Tecoras door registered for patent - Air outlet grills, 90 oriented, no thermal short circuit in the external air - From 16 mm installation depth, extrusion frame design and screw-free cover - Internal temperature-dependent fan speed control guarantees optimal internal cabinet temperature, maximum lifecycle and minimum noise emission - Filterless system, consequently, simple cleaning is possible - Hidden cable entry on hinge side, no cable and plug in the useful space of the cabinet - One variant for left and right door - Fan exchange in the internal and external circuit without dismounting the heat exchanger from the door - Individual fuse protection for each fan on the control board, prefusing required - Customer-specific adaptations possible with platform design - Supply voltage, 48 VDC (optional 24 VDC) - Protection rating, IP 55 internal circuit / external circuit - Sound pressure level. 55 db (A) at a distance of 1 m in accordance with ISO 7779, in the built-in cabinet up to 85 W/K Material - Enclosure of aluminium, 1.5 mm, partially with extruded aluminium -Heat exchanger of 0.25 mm aluminium - Silicon-free seals 1 Heat exchanger 1 Operating instructions - Fully assembled W H D W/K V A Model Order no. UP 465 888 102 (118) 65 48 10 K-HEX 65 01.920.500.0 1 unit 465 1066 147 (16) 85 48 6 K-HEX 85 01.920.60.0 1 unit 565 1600 147 (16) 145 48 20 H-HEX 145 01.920.607.0 1 unit 565 1155 147 (16) 150 48 20 K-HEX 150 01.920.608.0 1 unit S als th c t Net ork Sp cial Catalogu! Wh re you will find more products: 19 Rack systems Free-standing and wall cabinets TFT Drawers KVM Switches UPS Solutions RMS-System Thermal management.18

Tecoras Cooling unit (ACU R) TEC20060 High-capacity, compact cooling unit for door installation in TECORAS outdoor cabinets Approvals - CE - UL approval Principle - High-performance cooling unit with roating piston compressor - CFC-free referigerant, R 14a - Safe condensation dissipation to the outside - Direct mounting on the inside of the door, Identical mounting principle and uniform screwing conditions for all thermal components - IP 55 interface between heat exchanger and Tecoras door registered for patent - Air outlet grills, 90 oriented, no thermal short circuit in the external air - Adjustable air-break panel for minimizing thermal short circuit in the internal circuit - Adjustable internal cabinet temperature guarantees optimal internal cabinet temperature, maximum lifecycle and minimum noise emission - Equipment failure alarm with adjustable alarm temperature (internal cabinet temperature) - Filter-free system, easy cleaning is consequently possible - Cable entry offset to the hinge side, no cable and plug in the useful space of the cabinet - Test switch on the control board - One variant for left and right door - Fan exchange in the internal and external circuit without taking the cooling unit from the door - Output data for cooling unit built into Tecoras cabinet, determined in accordance with DIN 168, without moisture transport in the control cabinet - Supply voltage, 20 VDC / 120 VAC, 50 Hz / 60 Hz - Continuous use temperature up to 52 C - Protection rating, IP 55, internal circuit/external circuit - Noise pressure level, 55 db (A) at a distance of 1 m in accordance with ISO 7779, mounted cabinet up to 1800 W Material - Enclosure of aluminium, 1.5 mm 1 Cooling unit 1 Connection cable for AC 1 Plug for operation without door contact switch 1 Operating instructions - In fully assembled (W) W H D (V) (Hz) (A) (A) (W) Model Order no. UP 80 466 26 114 (10) 20 50/60 1,5, 20 ACU R 400 20 V/AC 01.920.912.0 800 466 888 157 (172) 20 50/60 2,4 11,5 550 ACU R 800 20 V/AC 01.920.900.0 800 466 888 157 (172) 120 50/60 4,8 2,0 550 ACU R 800 115 V/AC 01.920.901.0 1200 466 1066 157 (172) 20 50/60 4,5 15,0 800 ACU R 1200 20 V/AC 01.920.904.0 1200 466 1066 157 (172) 120 50/60 9,0 0,0 800 ACU R 1200 115 V/AC 01.920.905.0 1800 466 1066 157 (172) 20 50/60 5,0 22,0 1200 ACU R 1800 20 V/AC 01.920.906.0 1800 466 1066 157 (172) 120 50/60 10,0 44,0 1200 ACU R 1800 115 V/AC 01.920.907.0 2700 566 1600 157 (172) 20 50/60 8,0 0,0 1700 ACU R 2700 20 V/AC 01.920.910.0 Heating Unit Supply voltage 20 VAC/50(60) Hz, Axial fan: air throughput 5 m /h with 150 W, from 00 W 108 m /h, 950 W 160 m /h, Thermostat: temperature setting from 0 to 60 C Heating element protection with temperature monitor in the event of fan failure Protection rating IP 20 1 Heating fan, 20 VAC/50(60) Hz 1 Thermostat with contact break 1 Connecting cable, 1,5 mm 2, 1,5 m cable length 1 Mounting panel Mounting material Fully assembled W H D W/K V A Model Order no. UP 108 85 19 150 01.910.900.9 1 unit 15 85 182 00 01.910.901.9 1 unit 15 85 182 400 01.910.902.9 1 unit 145 85 240 600 01.910.90.9 1 unit 145 100 200 950 01.910.908.9 1 unit TEC005.19