No Cause for Alarm: A Holistic Approach to Identification, Prioritization, and Reduction

Similar documents
"It's Alarming Simple Steps To Reduce Nuisance Alarms

Alarm Fatigue in the ICU. Lynn Maguire MS, RN, PMC, NE-BC

Alarm Management. Objectives

Clinical Alarm Effectiveness: Recognizing & Mitigating Risk to Patient Care

Focus on Respiratory Care & Sleep Medicine Irvine, CA. Alarm Management. September 14-15, 2018

Alarm Management at Boston Medical Center A Roadmap to Safe Silence

The Joint Commission's National Patient Safety Goal on Alarm Management: How Do We Get Started?

Impact Of Clinical Alarms On Patient Safety. American College of Clinical Engineering Healthcare Technology Foundation (AHTF)

Managing Clinical Alarms

T1 BEDSIDE MONITOR GUIDELINE

Patient Alarm Messages

Passport 12m and Passport 17m BEDSIDE MONITOR GUIDELINE 5.21 Software Version NAME: HOSPITAL: DATE: VALIDATOR: Performed

Improving Alarm Management Utilizing Technology. NJ/DVHIMSS Annual Fall Event. Empowering the New Healthcare Era

Alarm Safety in 2017:

You finally make it home after a long shift, shower,

Alarms That Deserve Attention. Mike Rayo 3/29/2016

Ensuring the Effectiveness of Clinical Alarm Systems

Reference Case: Avera Heart Hospital Data-Driven Approach Helps Hospital Build Effective Clinical Alarm Management Program

A Novel Approach to Cardiac Alarm Management on Telemetry Units. Medical Device Alarm Safety in Hospitals Joint Commission Webinar May 1, 2013

Capnostream 20p Bedside Capnography Monitor. The only integrated, complete picture of oxygenation and ventilation 1

Clinical Alarm Management Strategies Meaningful Alerts

General Skills. yes. Device controls, buttons, indicators, and connectors

Running head: REDUCING THE HARM ASSOCIATED WITH CLINICAL ALARMS 1

2011 National Clinical Alarms Survey: Perceptions, Issues, Improvements and Priorities

Alarm and Measurement Default Settings

Hospital Ward Alarm Fatigue Reduction Through Integrated Medical Device Instruction and Hospital System Policy

T1 Monitor/Module Default Settings

Why Clinical Alarms are a TOP TEN Hazard

Safety Innovations FOUNDATIONHTSI. Using Data to Drive Alarm System Improvement Efforts. The Johns Hopkins Hospital Experience

Addendum to the Instructions for Use

Transport Pro Patient Monitor Operator s Manual Software Version 2.1

False Alarm Suppression in Early Prediction of Cardiac Arrhythmia

DPM4 Bedside Monitor Default Settings

Kendall DL Cable and Lead Wire System. Your Disposable ECG Cable and Lead Wire Safety Solution. Safe, Simple, Secure

Customizing Alarm Limits Based on Specific Needs of Patients

HeartStart XL+ User Training Workbook. Model No

GE Healthcare. Dash Variable-Acuity Monitoring

BeneVision Central Monitoring System. Quick Reference Guide

Contents of ANSI/AAMI HE75:2009 Page

Clinical Information Center Pro v5 (CIC Pro)

DPM Summary of Features and Benefits

THE CLINICAL CONNECTION

Bernoulli Smart Alarms & Surveillance: Applying Analytics in Real-Time

Track the truth. Give no false assurance. Do no harm. Nellcor SpO 2. Module for use with Philips IntelliVue * Patient Monitors

Safety Innovations FOUNDATIONHTSI. Plan, Do, Check, Act: Using Action Research to Manage Alarm Systems, Signals, and Responses

BEDSIDE MONITORING Dash 3000/4000 V5

Safety Innovations FOUNDATIONHTSI. Cardiopulmonary Monitors And Clinically Significant Events in Critically Ill Children

OMNI TOUCH SCREEN PATIENT MONITOR

HeartStart XL+ Configuration Worksheet

Cl inician Training Packet

The Complexity of Clinical Alarm Systems

Sound the Alarm! Strategies for Alarm Management in the Rush NICU. October 21 st, 2015

An Integrative Review

Framework for Alarm Management Process Maturity

PATIENT MONITORING SYSTEMS

Propaq LT Outline Train the Trainer

Vitalmax 4000 CL Product Specifications

PATIENT MONITORING SYSTEMS

URGENT: MEDICAL DEVICE CORRECTION Plum 360 Infusion System List Number: 30010

INSTRUCTIONS FOR USE. IntelliVue X2. Multi-Measurement Module Release G.0 with Software Revision G.0x.xx. Patient Monitoring

URGENT - Field Safety Notice Medical Device Correction

Ultraview SL Command Module Parameter Set ECG NIBP TEMP IP CO SpO2 Options SL Command Module: A B Our goals are simple:

Preventing ECMO Patient Harm While Using Remote Monitoring: A Case Report. Emily Thunstrom

Ultraview SL2400 With Wireless-LAN-Option

Instructions for Use Vista 120

GE Healthcare Healthcare Systems 9900 Innovation Drive Wauwatosa, WI USA

Battery Performance Alert

Omni (K) PATIENT MONITOR

Nellcor Bedside SpO 2 Patient Monitoring System, PM100N

Infinity M300 Patient Worn Monitoring

User s Reference Manual Volume 1 System Information

2013 Compliance Report RCW 52.33

Applicable To Employees of the Gundersen St. Joseph s Hospital laboratories and Gundersen Tri-County Hospital laboratories.

Connex Integrated Wall System 2.2 Software Version

Improving Alarm Response in ICU/CCU

Atlas Monitor Outline Train the Trainer

AST Guidelines for Best Practices in Alarm Management in the Operating Room

Clinical Alarm Management. Compendium

This is an incident action status report from the Contra Costa EMS Agency on Fire Station Closures affecting the communities of Lafayette, Martinez,

80BPM 36.5 C 35/ / 80. Panorama CENTRAL MONITORING SYSTEM. efficient flexible versatile (18) (94) Adult A SMITH, ERICA (92) 5RPM.

Servo i. CRC 335 University of South Alabama Cardiorespiratory Care

Instructions for Use. Infinity Vista. Infinity Patient Monitoring Series

INSTRUCTIONS FOR USE. IntelliVue Patient Monitor. MP5 Release G.0 with Software Revision G.0x.xx. Patient Monitoring

Battery Performance Alert: A TOOL FOR IMPROVED PATIENT MANAGEMENT FOR DEVICES UNDER BATTERY ADVISORY

PAT I E N T M O N I TO R I N G N E T W O R K

OPERATOR S MANUAL. NPB-4000/4000C Patient Monitor

Improving Clinical Alarm Management: Guidance and Strategies

GE Healthcare. Quick Guide. Dash 2500 Patient Monitor

Scope of Work Urban Design Review Framework Monitoring Program Item #7.1

CNAP MONITOR 500 HD QUICK GUIDE. This Quick Guide DOES NOT REPLACE the user manual!

Original Article. Intra-operative monitoring many alarms with minor impact. Summary

ELECTRICAL SAFETY IN HEALTHCARE FACITILIES

Laser Safety, Utilization and Credentialing Policy

SPECIFICATION FOR MULTIPARAMETER MONITOR

The information in this document is subject to change without notice.

qube mini Overview

Operating manual Reusable Pulse Oximetry Sensors

1 Appendix - Product Specifications

SureSigns VS4 Vital Signs Monitor

Optimization of Workflow Processes & Resources Through the Focused Deployment of Enabling Technologies

Transcription:

No Cause for Alarm: A Holistic Approach to Identification, Prioritization, and Reduction Pascha E. Schafer, MD, FACC Medical Director, Cardiac Care Unit Medical College of Georgia at Georgia Regents University 1

Objectives Identify performance improvement opportunities to decrease non actionable alarms Discuss how to capture, analyze, and utilize data Differentiate actionable versus non actionable alarm signals using an evidence based approach Describe the components of a successful alarm management strategy through improvements in clinical care and operational effectiveness 2

Presentation Outline Alarm Overview Georgia Regents Initiative Initial Data Collection & Analysis Georgia Regents Changes & Process Post Change Data Results Next Steps

4 Alarm Fatigue: The Healthcare Worker Perspective

Staff Feedback We can adjust limits but we can t turn any alarms off. Not even irregular heart rate. The Monitor Techs manage the alarms. They will call us if there is a problem and they silence the alarms, we don t. We did do education on changing the electrodes everyday, but I m not sure everyone does that. I m not sure how you get the alarm settings back to the defaults. I hear alarms going off all the time and it seems as if nobody pays attention to them or tries to adjust them. It can be hard to get someone to respond and to change the batteries. We don t currently have a policy for who gets monitored but we are looking at developing one using the AHA guidelines. I know people don t always discharge between patients since I have seen data in there from before the patient was admitted. I m not sure what process is used to adjust alarm limits so they are appropriate for the patient. 5

Alarm Fatigue: The Patient Perspective The nurse told me it wasn t anything important and I could just silence it any time it went off. What if I hit the wrong button or did it for the wrong thing? They said it didn t mean anything. Then why is it going off? The alarms go off and on all the time and nobody seems to notice or to care. I waited and waited, but nobody came in to see what the alarm was for. It eventually went off on its own. When my mom was in the ICU, it seemed like alarms were going non stop. These are representative comments from patients and family members in discussing the need for improved noise and alarm management. Photos courtesy of Lisa Pahl 6

Causes of Alarm Fatigue Units have high noise levels and numerous alarms Monitors Infusion pumps Call bells Phones Bed alarms Ventilator alarms Etc., Alarm limits are not tailored to patients Poor skin prep and electrode placement Lack of preventive maintenance/troubleshooting Lack of trust in the system 7

Alarm Management Must be a Priority Alarms cause stress for healthcare professionals Sound levels of 80 decibels common in clinical units Alarm fatigue results in depression and reduced productivity in nursing staff More than 50% of nursing staff identify themselves as affected by alarm fatigue Alarms cause stress for patients and interrupt sleep This may delay recovery, extend length of stay, and result in worse long term function Most alarm signals are NOT actionable 50 80% according to published literature 8

Actionable Alarm Signals Require clinical intervention or some type of action Life threatening, immediate response or action required Change in patient status, requires action to reverse or prevent further deterioration Requires action to prevent harm Requires action to correct a technical problem to assure proper patient monitoring (e.g., leads off, SpO2 sensor disconnected) 9

Non actionable Alarm Signals Do not require a clinical intervention or action Short duration, self correcting (e.g., SpO2 alarm signal) Intentional (e.g., suctioning or positioning/moving a patient) Triggered due to tight limits rather than actionable ones False alarm System itself incorrectly identifies an alarm condition Something interferes with system causing it to detect an alarm, e.g., artifact or low voltage triggered asystole 10

Alarm Management Strategy And Goals Use a comprehensive, multi faceted approach to incorporate experts and best practices Reduce non actionable alarms and alarm fatigue Ensure staff accountability and responsiveness to alarms Enhance patient care, patient safety, and patient experience Create a quieter, more healing environment Evaluate and optimize technology Improve productivity and work flow Increase patient and staff satisfaction Promote and model a culture of safety Enhance patient and family trust Align/meet TJC NPSG on Alarm Management 11

Alarm Management Current State Assessment A comprehensive, holistic approach to provide sustainable solutions CULTURE People Processes Technology DATA ANALYSIS 12

Georgia Regents Health System Academic Health Center in Augusta, Georgia 478 bed Georgia Regents Medical Center 154 bed Children s Hospital of Georgia including the region s only Level IV NICU Critical Care Center, housing a regional Level I Trauma Center GR Health Philips formed a 15 year business alliance in 2014 13

Response to TJC National Patient Safety Goal GRHealth System Leadership chartered a multidisciplinary Clinical Alarm Management Work Group Phase I (beginning January 2014): Identify the most important alarm signals to manage based on the following 1. Input from the medical staff and clinical departments 2. Risk to patients due to lack of response or malfunction 3. Specific alarms that are not needed or simply contribute to noise/fatigue 4. Potential for patient harm based on internal incident history 5. Published best practices and guidelines 14

GRU Clinical Alarm Management Work Group Pascha Schafer, MD (Co Chair, CCU) Ruth Wilson (Co Chair, NICU) Sue Ellen Abney Roberts (OB) Jennifer Anderson (RT) Stephanie Bowden (NICU) Jackie Bryant (Pharm) Kelley Connelly (Phillips) LeeAn Courtney (ED) Aleasha Couture (MICU) Kevin Dellsperger, MD (CMO) Julie Dey (4S/Dialysis) Steven Duckworth (IT) Leslie Edney (Perioperative) Theresa Ehntholt (PICU) Judith Gast (QM) Kristy Hardin (MICU) Colleen Hirschkorn (Phillips) Jody Hodges (Biomed) Michele Hoehn (CHOG/Surg) Latasha Holmes (Nursing Informatics) Sandra Klein (Perioperative) Brad Landrum (IT) Anni Mathews (PICU) Trent McGlynn (Phillips) Diana Minks (Phillips) Gloria Moxley (Perioperative) Steve Whitney (SICU/Card) Jill Williams (3W) Gloria Wright (CHOG 4/5) 15

Monitoring Process Mapping Many sources of non actionable alarms exist due to monitoring process complexity One piece of an extensive process mapping 16 16

Unit Clinical Alarm Inventory* Y or N Clinical Equipment Alarms Typical usage: 1=Constantly 2= Regularly 3=Infrequently Priority A=Highest; could result in death if unattended Centrally B=High priority; may lead to Monitored Y or N unintended consequence if unattended C= Low priority; little risk if unattended Is adequate level of oversight typically available? Y or N Comments 17 Telemetry monitors IV Infusion pump Syringe pump Ventilator CPAP/BIPAP Pacemaker (transcutaneous)* IABP Blood/fluid Warmer Fetal monitor Infant Radiant Warmer ET CO2 (refer to Ventilators) High flow O2 (Refer to Ventilators) Oxygen Analyzer Pulse oximeter (free standing) Dialysis CVVHD Dialysis PD Cycler Transport monitor Transport Vents (direct) Defib (Transport Monitor) ICP CVP Heart Rate Respiration Rate Pulse Ox (refer to above for continu.) CORE Temp. Arrhythmia Bed Alarm Fall prevention Chair Alarm Fall prevention PCA pumps Hyperthermia blanket Hypothermia blanket Isolette Nurse Call Humidifier Feeding pump SCD machine Wound VAC Free standing VS machine Pneumatic tubes Med Gas Bed lock Cooling Pumps Home Apnea monitors/ PCG Monitors** Transport Isolette* Water Treatment Video EEG *Association for the Advancement of Medical Instrumentation (AAMI) website

Unit Clinical Alarm Inventory* Y or N Clinical Equipment Alarms Typical usage: 1=Constantly 2= Regularly 3=Infrequently Priority A=Highest; could result in death if unattended Centrally B=High priority; may lead to Monitored Y or N unintended consequence if unattended C= Low priority; little risk if unattended Is adequate level of oversight typically available? Y or N Comments Telemetry monitors IV Infusion pump Syringe pump Y or N Ventilator CPAP/BIPAP Pacemaker (transcutaneous)* IABP Blood/fluid Warmer Fetal monitor Infant Radiant Warmer ET CO2 (refer to Ventilators) High flow O2 (Refer to Ventilators) Oxygen Analyzer Pulse oximeter (free standing) Dialysis CVVHD Dialysis PD Cycler Transport monitor Clinical Equipment Alarms Transport Vents (direct) Defib (Transport Monitor) ICP CVP Heart Rate Respiration Rate Pulse Ox (refer to above for continu.) CORE Temp. Arrhythmia Bed Alarm Fall prevention Chair Alarm Fall prevention PCA pumps Hyperthermia blanket Hypothermia blanket Isolette Nurse Call Typical usage: 1=Constantly 2= Regularly 3=Infrequentl y Centrally Monitored Y or N Priority A=Highest; could result in death if unattended B=High priority; may lead to unintended consequence if unattended C= Low priority; little risk if unattended Is adequate level of oversight typically available? Y or N Comments Humidifier Feeding pump 18 SCD machine Wound VAC Free standing VS machine Pneumatic tubes Med Gas Bed lock Cooling Pumps Home Apnea monitors/ PCG Monitors** Transport Isolette* Water Treatment Video EEG *Association for the Advancement of Medical Instrumentation (AAMI) website

19

20

Additional CAMW Action: Phase I Reviewed published best practices Attempted internal incident history review Identified highest priority alarms Adult telemetry/arrhythmia (GRMC) Pediatric pulse oximetry (CHOG) 21

Data Collection Modalities PIIC ix (Central Station) Audit log is incorporated into the product Can review alarm data directly at any time Can export data onto a thumb drive or obtain remotely Data is available for any PIIC ix device attached to the server Includes data for selected Inop alarms Can download up to 90 days of alarm data IntelliSpace Alarm Reporting (IAR) Tool SW on a separate PC that pulls data from either the PIIC or the PIIC ix Can collect data from either the PIIC or the PIIC ix Can export data onto a thumb drive or obtain remotely Provides data on all monitoring alarms, including all inop/technical alarm signals Expanded storage capabilities of up to 15 months of alarm data 22

Initial Alarm Data For MICU and 6N (Telemetry) Collected over a two week time period 54,000 52,000 52,729 50,000 48,000 46,000 46,358 44,000 42,000 Total Alarms MICU 6N 23

Broad Categories of Alarm Signals Captured Assessing high, medium, and low priority occurrences Red (High Priority) Arrhythmia Alarm Signals Yellow (Medium Priority) Arrhythmia Alarm Signals Red (High Priority) Bed/Parameter Alarm Signals Yellow (Medium Priority) Bed/Parameter Alarm Signals Inop/Technical Alarm Signals Asystole Vfib/Tach Vtach Extreme Tachy Extreme Brad PVC Alarms Beat Detection Alarms Rate/Rhythm Alarms HR Limit Alarm SpO2 Desat Apnea Invasive Line Disconnect Extreme Pressure Limit Low or High Limits for: SpO2 Resp NBP Invasive Pressure Temp QTc CO2 Leads Off Replace Battery Key Point The list of alarms within each of the broader categories is not all inclusive. Data captured will vary depending on parameters monitored, age of devices, and whether PIIC ix or the IAR tool was utilized. 24

Initial Alarm Data For MICU & 6N Alarms totals per category can help prioritize focus areas Number of Alarms Over 2 Weeks 45000 40000 35000 30000 25000 20000 15000 10000 5000 0 MICU 6N Red Arrhythmia 764 1004 Yellow Arrhythmia 13252 38218 Red Parameter 4166 487 Yellow Parameter 33073 3457 Inop/Technical 1474 3192 25

Alarm Data By Each Type Of Alarm: MICU Can identify specific alarms to address MICU Red Arrhythmia Alarm Totals MICU Yellow Arrhythmia Alarm Totals 400 350 3500 3000 3097 300 250 200 150 100 50 0 252 194 130 110 78 Asystole Vfib/Vtach Vtach Extreme Tachy Extreme Brady 2500 2000 1500 1000 500 0 1567 658 773 75 454 34 1804 1026 100 152 57 18 231 2229 12 284 681 26

Alarms Per Patient: Patient Outliers? Deep dives can provide information on process and customization Total Alarm Signals Per Patient Bed Over 24 Hours Summary A total of 1,947 alarms were generated by one patient and the majority of the alarms for Low Heart Rate. The low limit was set at 75. Except for 12 of the alarm signals, all of the alarms that occurred were triggered by heart rates between 70 and 74. 27

Evaluating The Potential Impact Of Alarms It is not just alarm fatigue for the nurses One patient in an ICU had a total of 907 alarms in a 24 hour time period A disruption every 1.5 minutes for the nurse and for the patient! Impacts patient care, patient and staff satisfaction and workflow This does not include all of the other alarms going off in the patient room (i.e. ventilators, IV pumps, etc.) 28

CAMW Action: Phase II (by January 2016) Develop and implement specific components of policies and procedures that address Clinically appropriate settings When alarms can be disabled When parameters can be changed Who can set and change parameters and or set to off Monitoring and response expectations Checking individual alarm signals for accurate settings, proper operation and detectability Educate those in the organization about alarm system management for which they are responsible 29

Baseline Data Collection Two week blocks in MICU and 6N Number of alarms indexed per patient per day Plan for serial interventions with follow up data collection (2 week blocks) to assess response to each individual intervention Distributed in dashboard format Successful interventions will go house wide on rolling basis 30

Intervention 1: Adjust Yellow Arrhythmia Defaults 6N Yellow Arrhythmia Alarms Summary Total 68,924 yellow arrhythmia alarm signals generated. New default would have eliminated 21,088 alarms. 30% reduction 31

Alarm Management Communication Example This was distributed and posted on the unit The Following Changes Will Be Made On 6N On February 19 th we will initiate our first intervention to address the issue of Alarm Fatigue at our institution. The following alarms will be defaulted to OFF: 1. Non sustained ventricular tachycardia (which only applies to 3 and 4 beat runs) 2. Run PVCs (redundant with #1) 3. Pair PVCs 4. Ventricular Bigeminy 5. Ventricular Trigeminy 6. Multiform PVCs 7. Pause (currently set greater than 2 seconds) In addition, the red alarm default for asystole will be changed from 4 seconds to 3 seconds. Notifications The physicians have been notified by the physician Co Chair that these changes are being made Assessing The Impact Alarm data was collected and analyzed for two weeks previously Alarm data will be collected and analyzed for two weeks following the configuration changes in order to evaluate the impact on the total number of alarms occurring Expectations Any of the above alarms may be turned back on if deemed clinically appropriate, and the physicians and nurses may coordinate with the 6N alarm techs to do this The plan is to keep a close record of any possible negative outcomes related to these changes, including any nearmisses, Rapid Response calls, or Code Blue events If you perceive any near miss events, please document and notify the Nurse Manager of 6N If you have any other questions or concerns, please contact your Nurse Manager The 6N nursing staff has been notified by the Nurse Manager that these changes are being made 32

Post Change Alarm Data Comparisons 60,000 50,000 52,729 46,358 6 % Increase 56,069 40,000 30,000 32% Reduction 31,576 20,000 10,000 0 Total Alarms Pre MICU 6N Total Alarms Post 33

Pre Change Data 6N & MICU: Category Variation Expectation that adjusting yellow arrhythmia would have greatest impact on 6N 6N Total Alarms Per 2 Weeks: 46,358 MICU Total Alarms Per 2 Weeks: 52,729 487 6N Alarm Category Pre Change 3457 3192 1% 8% 7% 1004 2% MICU Alarm Category Pre Change 1474 3% 764 1% 13252 25% 38218 82% 33073 63% 4166 8% 34

Assessing Pre and Post Change Data MICU Yellow arrhythmia category only a small portion of MICU alarms MICU Alarm Category Pre Change 1474 3% 764 1% 13252 25% MICU Alarm Category Post Change 1281 2% 1014 2% 7076 13% 4706 8% 4166 8% 33073 63% 41992 75% 35

Assessing Pre and Post Change Data 6N Yellow arrhythmia category a large portion of the 6N alarms 487 6N Alarm Category Pre Change 3457 3192 1% 8% 7% 1004 2% 38218 82% 6819 22% 802 6N Alarm Category Post Change 2% 4372 14% 1050 3% 18533 59% 36

Yellow Arrhythmia Alarms Per Patient Bed Per Day 120 46% Reduction 114 60% Reduction 100 80 60 40 20 39 21 46 0 MICU Pre-Change Post-Change 6N 37

38 Total Alarms Per Patient Bed Per Day for 6N Comparing pre and post change data

Impact On Total Alarms Per Patient Bed Per Day Comparing MICU and 6N 6% Increase 180 160 157 167 41% Decrease 140 132 120 100 80 78 60 40 20 0 MICU 6N Pre-Change Post-Change 39

Additional CAMW Action: Phase II Educating Faculty and Staff on Clinical Alarm Management Grand Rounds, Section Meetings, and Quality Unit Councils Nursing Skills Fair Online training (Future) Educational program for lead placement Skin prep and proper electrode placement Routine battery replacement Routine change of electrodes Documentation in nursing assessment in EMR New Clinical Alarm Management Policy Telemetry order set based on AHA Telemetry Practice Standards CHOG pilot units Tailoring baseline settings and lead size to age group MICU default parameter settings 40

Next Steps Continue with incremental changes and measure the results Engage Alarm Champions (staff) to partner with Alarm Committee to roll out changes and be change agents Explore technology optimization and use of IntelliSpace Event Management (IEM): Evaluate use model Identify ROI 41

42 Technology Optimization Utilize other tools to analyze trends and changes in patient status in conjunction with alarms

In Summary Any Alarm Management Strategy must be carefully planned, tested, and continuously evaluated to assure achievement of the right balance of patient safety and quality of care with the reduction of alarm fatigue. Photo courtesy of Lisa Pahl 43

Thank you

References 1. ECRI Institute, "Alarm Safety Resource Site", online, accessed 2012, https://www.ecri.org/forms/pages/ Alarm_Safety_Resource.aspx 2. Cvach, M., "Monitor Alarm Fatigue: An Integrative Review", Biomedical Instrumentation & Technology, July/Aug 2012, 268 277. 3. AAMI, FDA, TJC, ACCE, and ECRI Institute Clinical Alarms Summit 2011, http://www.aami. org/publications/summits/2011_alarms_summit_ publication.pdf 4. Chambrin, M., et al. Multicentric study of monitoring alarms in the adult intensive care unit (ICU): a descriptive analysis, Intensive Care Medicine, 1999, V: 12 E:12, pp. 1360 1366. 5. Schmid, F., et al. The Wolf Is Crying in the Operating Room: Patient Monitor and Anesthesia Workstation Alarming Patterns During Cardiac Surgery, Anesthesia & Analgesia, Jan 2011, V: 112 E: 1, pp. 78 83. 6. Aboukhalil, A., et al.reducing false alarm rates for critical arrhythmias using the arterial blood pressure waveform, Journal of Biomedical Informatics, 2008, V: 41, pp.442 451. 7. Siebig, S., et al. Collection of annotated data in a clinical validation study for alarm algorithms in intensive care a methodologic framework, Journal of Critical Care, 2010, V: 25, pp. 128 135. 8. Blum, J., et al. Specificity improvement for network distributed physiologic alarms based on a simple deterministic reactive intelligent agent in the critical care environment, Journal of Clinical Monitoring and Computing, 2009, V: 23, pp. 21 30. 9. Gross, B., et al. Physiologic monitoring alarm load on medical/surgical floors of a community hospital, Biomedical Instrument Technology, Spring 2011, Suppl., pp. 29 36. 10. Hu, X., et al. Predictive combinations of monitor alarms preceding in hospital code blue events, Journal of Biomedical Informatics, 2012, V: 35 I: 5, pp. 913 921. 11. Borowski, M., et al. Reducing False Alarms of Intensive Care Online Monitoring Systems: An Evaluation of Two Signal Extraction Algorithms, Computational and Mathematical Methods in Medicine, 2011, V: 2011 Article ID: 143480, pp. 1 11. 12. Cropp, A., et al. Name that tone: the proliferation of alarms in the intensive care unit, Chest, 1994, V: 105.4, p. 1217. 13. Solet, J., et al. Managing alarm fatigue in cardiac care, Progress in Pediatric Cardiology, 2012, V: 33, pp. 85 90. 14. Varpio, L., et al. The Helpful or Hindering Effects of In Hospital Patient Monitor Alarms on Nurses: A Qualitative Analysis, Computers, Informatics, Nursing, 2012, V: 30 I: 4, pp. 210 217. 15. Korniewicz, D., et al. A National Online Survey on the Effectiveness of Clinical Alarms, American Journal of Critical Care, 2008, V: 17, pp. 36 41. 16. Bliss, J., et al. Behavioural implications of alarm mistrust as a function of task workload, Ergonomics, 2000, V: 43 I: 9, pp.1283 1300. 17. McNeer RR, Bohorquez J, Ozdamar O, Varon AJ, Barach P. A New Paradigm for the Design of Audible Alarms that Convey Urgency Information. Journal of Clinical Monitoring and Computing. 2007; 21(6):353 63. 18. Bitan, Y., et al. Nurses reactions to alarms in a neonatal intensive care unit, Cognition Technology and Work, 2004, V: 6, pp. 239 246. 19. Sobieraj, J., et al. Audibility of Patient Clinical Alarms to Hospital Nursing Personnel, Military Medicine, 2006, V: 171 I: 4, pp. 306 310. 20. Wee, A., et al. Are Melodic Medical Equipment Alarms Easily Learned?, Technology, Computing, and Simulation, 2008, V: 106 I: 2, pp. 501 508. 21. Block, F., et al. Optimization of alarms: a study on alarm limits, alarm sounds, and false alarms, intended to reduce annoyance, Journal of Clinical Monitoring, 1999, V: 15, pp. 75 83. 22. Halpern, NA., et al. Critical care medicine in the United States 2000 2005: an analysis of bed numbers, occupancy rates, payer mix, and costs. Crit Care Med. 2010 Jan;38(1):65 71.