CPR. New EU regulation for construction materials.

Similar documents
Belcom Cable excellence engineered through quality. CPR Construction Products Regulation

Üntel is ready for CPR

CONSTRUCTION PRODUCTS REGULATION MOLEX CES COPPER AND FIBRE CABLE

DID YOU GET USED TO THE NEW CPR? HERE S A QUICK REVIEW!

White paper. Construction Product Regulations* by Multimedia Connect. Which cables are concerned by these new regulations?

Construction Products Regulation (CPR) and BS 6701

YOUR GUIDE TO UNDERSTANDING CPR

1. Terms defined in the Construction Products Regulation (CPR)

Europacable FAQ on CPR Status: 26/01/17

Implementing the Construction Products Regulation (EU) 305/2011

Regulation 574_2014: Annex III CPR. and. Regulation 568_2014: Annex V CPR

Construction Products Regulation (CPR)

Guidance Note No 21/1. CE Marking Windows and doorsets to BS EN 16034

Frequently Asked Questions on the Construction Products Regulation (CPR) - Enterprise and Industry

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Significance of the Construction Products Regulation, including for data centers WHITEPAPER

Construction Products Regulation (CPR) and cables. British Cables Association Guidance to Specifiers

The New EU-Regulation on Construction Products

ETICS and the EU Internal Market The European framework. G. Katsarakis European Commission, DG GROWTH Unit C-1: Clean technologies and products

GNB-CPR Position Paper: Issuance of certificates under CPR

COMMISSION DELEGATED REGULATION (EU)

Implementation of the Construction Products Regulation (CPR) in harmonized standards - Template for Annex ZA -

Guideline Construction Products Regulation (EU) 305/20122

Declaration of Conformity Declaration of Performance Notes

AFIREFENIX SZ1-K 0,6/1 kv PH120 (AS+)

CE marking of noise barriers and foundations

Guidance from the Group of Notified Bodies for the Construction Products Regulation 305/2011/EU

Guidance Note No 19/1. CE Marking windows and doorsets

The New Generationn of Firedoors

CPR: EUROCLASSIFICATION & TESTS FOR CABLES

DRAFT COMMISSION DELEGATED REGULATION (EU) / of XXX

CPR Guide: EU Rules Practical Impact

RULEBOOK ON ELECTROMAGNETIC COMPATIBILITY

CPR Guide: EU Rules Practical Impact

Technical Bulletin CE marking: from 1st July 2013

Council Directive 93/68/EEC of 22 July 1993 amending Directives

best practice guide Pedestrian doorsets Fire resisting and/or smoke control characteristics - to

New European Cable Testing and Classification

European Technical Assessment

SUPPLEMENTARY REGULATIONS SPECIFIC TO CERTIFICATION OF PERSONAL PROTECTIVE EQUIPMENT (PPE)

BT Cables Technical Seminar CIBSE South Wales Region. Nov 17

COMMISSION DELEGATED REGULATION (EU) /... of

DNVGL-CP-0401 Edition February 2016

Construction Products Directive

Federal Law of the Russian Federation of December 27, 2009 N 347-FZ "Technical regulation on safety of low-voltage equipment" Part I

Centexbel. General certification regulations. Construction products

CE Marking for Fire Resistant doors. The future EN Agustín Garzón Cabrerizo Technical Director Fire Resistance Lab.

Council of the European Union Brussels, 21 March 2017 (OR. en) Mr Jeppe TRANHOLM-MIKKELSEN, Secretary-General of the Council of the European Union

BUSINESS PLAN CEN/TC 305 POTENTIALLY EXPLOSIVE ATMOSPHERES EXPLOSION PREVENTION AND PROTECTION EXECUTIVE SUMMARY

Georgios Katsarakis European Commission

DIRECTIVE 2014/34/EU OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL

EUROPEAN UNION. Brussels, 13 February 2014 (OR. en) 2011/0357 (COD) PE-CONS 54/13 ENT 190 MI 550 CONSOM 128 COMPET 470 CODEC 1481

Your Key to achieving C.E Marking Compliance

EUROPEAN TECHNICAL ASSESSMENT

EUROPEAN TECHNICAL ASSESSMENT

BUSINESS PLAN. CEN/TC 336 BITUMINOUS BINDERS Version 2018 EXECUTIVE SUMMARY

UK Direction BS7671 BS 8492 BS /01/2018

COMMISSION DELEGATED DECISION (EU) / of XXX

(1135/2016) Translation from Finnish Legally binding only in Finnish and Swedish Ministry of Economic Affairs and Employment, Finland

BUSINESS PLAN CEN/TC 49 GAS COOKING APPLIANCES EXECUTIVE SUMMARY

Reaction to fire classification report No C-rev.1

A Notification under Article 12 of Regulation (EU) No 1025/2012 1

TFI Report Classification

DIRECTIVES. DIRECTIVE 2009/142/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 30 November 2009 relating to appliances burning gaseous fuels

For structural use in all types of construction works according to EN

DNVGL-CP-0399 Edition March 2016

BUSINESS PLAN CEN/TC 164 WATER SUPPLY EXECUTIVE SUMMARY

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

COMMISSION DELEGATED REGULATION (EU) /... of

On Electromagnetic Compatibility

Reaction to fire classification report No C

Working Document on a possible COMMISSION DELEGATED REGULATION

DECLARATION OF PERFORMANCE. No EN

DELTA Classification Report

Regulation (EU) No 305/2011 laying down harmonised conditions for the marketing of construction products (EU CPR)

Classification Report

Guidelines accompanying:

Gas Appliances Directive - Advisory Committee. Comité Consultatif de la Directive Appareils a Gaz

The products covered by the Regulation can be classified as follows:

Harmonisation and equivalence of reaction-to-fire performance classification in Europe: a small-scale desk-based study

TFI Report Classification

Transition from GAD to the GAR July,

The New EMC Directive 2004/108/EC

Hardware User s Manual

REACTION TO FIRE OF CABLE SYSTEMS. G. DENCHE* N. GENERÓ O. RODRIGUEZ Red Eléctrica de España S.A.U. Grupo General Cable Sistemas

(recast) (Text with EEA relevance) out the conformity assessment procedure. Conformity 20 February 2014.

Hardware User s Manual

Reaction to fire classification report No B

BUSINESS PLAN CEN/TC 79 RESPIRATORY PROTECTIVE DEVICES EXECUTIVE SUMMARY

Additional reaction to fire classification report No H

Hardware User s Manual

The New EMC Directive 2004/108/EC

DNVGL-CP-0402 Edition February 2016

Record of Amendments. Version Date Amendment Section/page affected

The Danish Energy Authority to carry out inspections in June and July 2012

(Non-legislative acts) REGULATIONS

Firetect C. Fire protective products: Fire protective board

Declaration of Performance

The PPE Directive and the PPE Regulation

EUROPUMP ATEX Guideline Part II

Transcription:

CPR New EU regulation for construction materials www.

Index Construction Products Regulation.... 4 What is the Construction Products Regulation (CPR)?.... 4 What is the objective of the CPR?.... 4 Who does the application of the CPR affect?.... 4 Why are cables affected by the CPR?... 5 What characteristics must the cables satisfy with respect to the CPR?.... 5 Since when must the CPR be applied to cables?.... 6 Which are the Euroclasses of the CPR that apply to cables?... 6 What does the Euroclass initial mean?... 7 Euroclass classification.... 8 How are cables assessed and verified externally?.... 9 Application scheme of the CPR.... 10 What is the declaration of performance DoP?... 10 What does the EC marking look like?... 11 Which standards are applicable for the CPR?... 12 Will the CPR will be applied equally in Europe?.... 12 Will the CPR bring about important modification in cables?.... 12 2

Construction Products Regulation (CPR) The European Union, with the aim of improving the safety of buildings, has created a construction products classification system in agreement with their fire behaviour, which is common for the whole of Europe within the Construction Products Regulation (CPR). The Institutions concern to protect people against fire is fully shared by Cables RCT and by the cable industry in general, and thus cables with low smoke and toxic gas emission have been developed. These cables give more time to evacuate in the case of fire and are less harmful for the protection teams, facilitating rescue tasks. The CPR, with its new product classification system and the quality control requirements entailed by this classification, represents an important step towards improving the performance of cables and their safety level, moving forward along the path that the cable industry has been setting for the last few years. 3

What is the Construction Products Regulation (CPR)? The Construction Products Regulation* CPR, is the European legislation that establishes the basic requirements and essential harmonised characteristics that all products designed to be permanently installed in construction works must satisfy within the EU application scope. Due to its legal nature, all social agents affected must directly comply with it: administration, manufacturers, dealers, users, etc. All the existing regulations and legislation in the European Union must be adapted before its entry into force to the harmonised technical specifications. *(EU) Regulation no. 305/2011, 9 March 2011 (published on 4 April 2011 in the Official Journal of the European Union) establishing harmonised conditions for marketing construction products, and abolishing EEC Directive 89/106 of the Council. Who does the application of the CPR affect? The players involved in the application of the CPR are the manufacturers, the dealers, the installers and engineering companies, as well as the competent Authorities of the EU member states. What is the objective of the CPR? There are different legislations for cables at European and national levels that result in different safety levels. The CPR regulation introduces new classification criteria and common classes, the socalled Euroclasses, for the entire European space, creating a common language and a classification, assessment and certification system for all member countries, for construction products. With regards to fire behaviour, it permits establishing common standards to carry out assessment comparisons in equivalent conditions, guaranteeing the veracity of the information the products subject to this regulation. Manufacturers and dealers are obliged to manufacture and market the products in agreement with the standards indicated in the CPR. Furthermore, manufacturers must make a Declaration of Performance (DoP), ratifying that the product meets the performance set by the CPR for a certain Euroclass. Products must be identified with marks and tags that show their classification. Finally, these properties and compliance with them must be validated by an independent body, the so-called Notified Bodies and Laboratories. The competent authorities of each member state are responsible for determining the conditions that the materials of each national territory must satisfy, establishing the safety levels that must be reached in agreement with the type of construction or installation, and verifying that the products marketed or installed satisfy the respective application requirements. Installers, engineering companies and end users are obliged to select the appropriate products in agreement with the construction, and they must satisfy the requirements established by the national authorities. Where appropriate, importers must also adopt all the necessary measures to ensure that the products they place on the market are in agreement with CPR requirements and with the mandatory national requirements. 4

Why are cables affected by the CPR? The CPR Regulation defines as construction product all those products designed to be permanently incorporated into construction works, in the broadest sense, not only considering building but also civil engineering works. Cables have been considered as construction products, and they are the only electrical products classified as construction products. Therefore, power, telecommunications, data and control cables are included. Cables designed for connecting appliances or for internal wiring of equipment or electrical appliances, and all those cables that are not used as cables for construction are excluded. What characteristics must the cables satisfy with respect to the CPR? The CPR regulates and establishes the characteristics that construction materials must satisfy with respect to fire. Therefore, the cables are only affected by the safety specifications in the case of fire (resistance and reaction to fire) and hazardous substances (emission and content). The other technical characteristics are defined in the regular standards. The fire reaction of a cable has three relevant aspects: firstly, the contribution to fire propagation by the heat given off in the actual combustion of the cable and by the burning particles given off; secondly, the amount and transparency of the smoke emitted; and finally, the acidity of the gases given off. We can define fire resistance as the capacity of a cable to maintain the electrical service of an installation during a fire. The greater fire resistance of a cable, the easier it will be to keep the emergency services in operation and therefore, permit evacuation. The standard that will develop this aspect is still in its draft phase. Finally, the declaration of hazardous substances, their emission and content, indicates which components and in what proportion they are emitted in normal conditions of use, not of fire, by the cables, in order to preserve the environment. The fact that the content of hazardous substances has been taken into account will be indicated in the DoP of each product, although no criteria have yet been defined to determine them. By way of conclusion, of the three aspects contemplated By the CPR, the most relevant one at this time is fire reaction, and including but not limited to the declaration of hazardous substances. The fire resistance aspect is still legal development pending. RCT - RZ1-K (AS) RCT - H07Z1-K 5

Since when must the CPR be applied to cables? The European Union has established the following calendar to apply the CPR (related to fire reaction and emission of hazardous substances). - Start of the transitional period of co-existence between current requirements and the CPR: 10 June 2016 - Full validity: 1 July 2017 1. Start CPR application 10 June 2016 2. Transitional phase until 30 June 2017 3. Full validity 1 July 2017 Which are the Euroclasses of the CPR that apply to cables? The European Union has created a single and uniform classification criterion in the whole of Europe (a common language) to define the fire reaction performance of cables. Hence, some classes have been defined*, using classification criteria in agreement the amount of heat emitted in presence of fire. Likewise, it contemplates that the manufacturer, lacking requirements related to fire reaction, can use the Undetermined performance option (Euroclass F ca ). *(EU) Delegated Regulation 2016/364, of 1 July 2015, on the classification of fire reaction properties of construction products. A ca B1 ca B2 ca C ca D ca E ca No reaction Very low reaction Non-flame propagator. Non fire propagator (1.75m) Very low heat emission Low reaction Non-flame propagator. Non-fire propagator (1.5 m) Low heat emission Reduced reaction Improved reaction Basic reaction Non-flame propagator. Non-fire propagator (2m) Reduced heat emission Non-flame propagator Improved heat emission Non-flame propagator d a b Smoke opacity Dropping particles Smoke acidity F ca Undetermined 6

What does the Euroclass initial mean? The designation of the fire reaction characteristics of electrical cables is based on a code that indicates their performance. This code specifies the Euroclass and, if applicable, additional classifications. C ca s1b Class; satisfies the nonpropagation of the flame or of the fire, and emitted heat limits Reduced smoke emission and transmittance of over 60% d1 a1 Flammable particles; no burning droplets or particles that persist for more than 10 s during the 1200 s of the test Reduced acidity and corrosiveness of the emitted gases (conductivity < 2.5 µs/mm and ph > 4.3) Digit 1 Digit 2 Fire propagation and heat emission performance, cable class (A ca, B1 ca, B2 ca, C ca, D ca, E ca, F ca ). A ca B1 ca - B2 ca C ca - D ca - E ca F ca Digit 3 They do not contribute to the fire. Minimum contribution to the fire. Combustible, they contribute the fire, from lower to higher contribution. Undetermined contribution properties. Burning droplets/particles (d0, d1, d2). This classification provides information about the dripping of burning material during the fire (d: droplet). d0 d1 d2 No burning droplets or particles. No burning droplets or particles that last more than 10 seconds. None of the above. Smoke emission properties (s1, s1a, s1b, s2, s3). This classification provides information about the opacity of the emitted smoke (s: smoke). s1 s2 s3 Digit 4 Acidity performance (a1, a2, a3) in addition applying the test described in standard UNE-EN 50267-2-3. This classification provides information about the emission of acid gases during the fire (a: acidity). a1 Conductivity < 2.5 µs/mm and ph > 4.3. a2 Conductivity < 10 µs/mm and ph > 4.3. a3 Little smoke production and slow smoke propagation. s1a Transmittance >80%. s1b Transmittance >60% and <80%. Average smoke production and propagation. None of the above. None of the above. We will thus obtain as many Euroclasses as combinations are possible between the previously mentioned classification criteria, bearing in mind that classes A ca, E ca and F ca are only designated by the digit 1 (class) as they do not have additional classification criteria. This classification system ranks equally in all European Union countries. 7

Euroclass classification Classification criteria Additional classification (only for classes B1 ca, B2 ca, C ca and D ca ) EN ISO 1716 EN 50399 EN 50399 EN 60332-1-2 EN 50399 EN 61034 EN 50399 EN 60754-2 Classes Calorific value Heat emission and Fire growth rate Non-fire propagation Non-flame propagation Smoke production Smoke transmittance Burning droplets and particles Acidity Contribution to the development of fire + Example E ca Class E ca It satisfies the non-flame propagation test, without additional classifications. C ca s1b d1 a1 Classification a1 Reduced acidity and corrosiveness of emitted gases with conductivity < 2.5 µs/mm and ph > 4.3 Classification d1 No burning droplets/particles that persist for more than 10 seconds. Classification s1b Reduced emission of smoke and transmittance of over 60% and less than 80%. Class C ca It satisfies the non-flame propagation test, with the requirement of non-fire propagation and with emitted heat limits for this class. s1 s2 s3 s1a s1b d0 d1 d2 a1 a2 a3 8

How are cables assessed and verified externally? The harmonised standard requirements vary depending on the fire reaction class declared, so there are different Assessment and Verification of Constancy of Performance (AVCP) systems according to the enclosed table, which are more demanding for the upper Euroclasses. These systems are based on the participation of entities not associated with the manufacturer which, according to the name of the CPR, will be the Notified Body and the Notified Laboratory. All the assessment and verification of constancy of performance systems require the manufacturer to carry out internal quality controls as well as to prepare the Declaration of Performance for each product. There are three assessment and verification of constancy of performance systems: 1+ This is the maximum requirement level and corresponds to Euroclasses A ca, B1 ca, B2 ca and C ca. A Notified Body must inspect and be responsible for the surveillance, assessment and control of the production, as well as control the execution of initial sample and monitoring tests by the Notified Laboratory. The frequency of the monitoring tests is the highest. 3 This level correspond to Euroclasses D ca and E ca. The manufacturer must perform initial verification and monitoring tests on the products with a Notified Laboratory, but the participation of a Notified Body is not compulsory. Consequently, depending on the fire reaction class declared, there are different assessment and verification of constancy of performance systems, which are summed up in the following table: Applicable Euroclass Verification elements Assessment and verification of constancy of performance systems 4 This level corresponds to Euroclass F ca. For the manufacturer, only the preparation of the Declaration of Performance is mandatory, and it corresponds, therefore, to the lowest requirement level. 1 + 3 4 Factory production control M M M Additional tests on samples taken from factory, in agreement with the determined test plan M - - Determination and test of the standard product by tests, calculation or tabulated values NB NL M Initial factory inspection and factory production control NB - - Factory monitoring inspection and factory production control NB - - Tests on samples taken before the product is launched onto the market NB - - NB Notified Body NL Notified Laboratory M Manufacturer 9

tfno. +34 976 500 120 Fax +34 976 500 138 info@rct.es www. Reacción al fuego e ca Director técnico www. Director técnico Different European organisations have requested and obtained recognition as Notified Body or Laboratory, and manufacturers can hire any one of them. In Spain, the external Notified Body is AENOR and the external Notified Laboratory is CEIS (Centre for Tests, Innovation and Services). Application scheme of the CPR A ca - B1 ca - B2 ca - C ca - D ca - E ca - F ca More additional classifications, if applicable (smoke, acidity and droplets/particles) AVCP Assessment and Verification of Constancy of Performance DoP Declaration of Performance What is the declaration of performance DoP? The manufacturer must prepare a Declaration of Performance (DoP). The declaration of performance is a legal document that must be placed at the disposal of the public, in which the manufacturer identifies the product and its programmed use, indicating the performance of the cable respect to its essential characteristics, which are currently, safety in case of fire (fire reaction according to UNE-EN 50575) and the emission of hazardous substances, although this is not assessed as currently there is no harmonised technical specification. Therefore, the manufacturer assumes the responsibility for the product conformity to the declared performance. Cables RCT will adopt the following actions respect to the DoP document: â â â EC Marking Not on the cable but in the packaging Declaration of performance Declaration of performance H03VV-F Declaración: 006-01 Código de identificación única del producto tipo: RCT40 Trazabilidad Orden de fabricación o número de lote, indicado en la documentación del producto Usos previstos del producto Suministro de electricidad en edificios y obras de ingeniería civil con el objeto de limitar la generación y propagación de fuego y humo Datos del fabricante cables rct SAU. ctra castellón Km 226,900-50720 - Zaragoza (españa) Sistema o sistemas de evaluación y verificación de la constancia de las prestaciones Sistema 3 H03VV-F Declaración: 006-01 Código de identificación única del producto tipo: RCT40 Trazabilidad Orden de fabricación o número de lote, indicado en la documentación del producto Usos previstos del producto Suministro de electricidad en edificios y obras de ingeniería civil con el objeto de limitar la generación y propagación de fuego y humo Datos del fabricante cables rct SAU. ctra castellón Km 226,900-50720 - Zaragoza (españa) Sistema o sistemas de evaluación y verificación de la constancia de las prestaciones Sistema 3 Legislation User Manufacturer Manufacturer plus the intervention of: - Notified Body: A ca, B1 ca, B2 ca, C ca - Notified Laboratory: D ca, E ca - Nobody: F ca Manufacturer Manufacturer A DoP will correspond to each marketed product, with an alphanumerical identification. These declarations of performance will be accessible free of charge on our website The DoP will contain the following information: - Manufacturer s name. - Product code. - Traceability. - Use of this product. - AVCP System. - Notified Body. - Declared performance and respective standards. - Date and manufacturer s stamp. Norma armonizada en 50575:2014+A1:2016 Organismos notificados CEIS Laboratorio notificado Nº 1722 Norma armonizada en 50575:2014+A1:2016 Organismos notificados CEIS Laboratorio notificado Nº 1722 Declaración de prestaciones Características Prestaciones Especificaciones técnicas armonizadas Reacción al fuego e ca en 50575:2014+A1:2016 Sustancias peligrosas npd (prestación no determinada) Gama de fabricación La presente declaración de prestaciones se emite bajo la sola responsabilidad de cables rct cables rct SAU ctra. castellón Km 226,900 50720 Zaragoza (españa) Declaración de prestaciones Características Prestaciones Especificaciones técnicas armonizadas en 50575:2014+A1:2016 Sustancias peligrosas npd (prestación no determinada) Gama de fabricación La presente declaración de prestaciones se emite bajo la sola responsabilidad de cables rct Pilar Soria - 4 de octubre 2016 - cables para todos los días, cables para toda la vida cables rct SAU ctra. castellón Km 226,900 50720 Zaragoza (españa) tfno. +34 976 500 120 Fax +34 976 500 138 info@rct.es www. Pilar Soria - 4 de octubre 2016 - cables para todos los días, cables para toda la vida www. 10

What does the EC marking look like? The EC marking symbol must be fixed in a visible, legible and indelible manner on the packaging used to market the cables, and it must be accompanied by additional information that is indicated in the harmonised standard. It is not compulsory for the marking to appear on the cable. Example of tagging with EC marking for a class Cca cable, is: The last two digits of the year when the marking was made for the first time Identification of the Notified Body (99 corresponds to AENOR) Identifying logo for Cables RCT products with a CPR rating Reference number of the Declaration of Performance (DoP) Unique identification code of the standard product Use foreseen for the product as indicated in the applied European standard VERDE GREEN VERT GRÜN RAL 6018 RZ1-K (AS) 0,6/1kV LSZH - Libre halógenos - Halogen free 3G 1,5 mm 2 Cca-s1b, d1, a1 0099 16 DoP: XXX Cod.: XXXX CABLES RCT www. Ctra. Castellón km 226,9 50720 La Cartuja Baja Zaragoza 500 m Made in Spain OF: XXXXXX 01/07/2017 00:00 EN 50575: 2014 A1: 2016 Suministro de electricidad en edificios y en otras obras de ingeniería civil con el objeto de limitar la generación y propagación de fuego y humo. Sustancias peligrosas: Propiedad no determinada. Supply of electricity in buildings and other civil engineering works with the objective of limiting the generation and spread of fire and smoke. Dangerous substances: No performance determined. Alimentation en électricité et communications dans les bâtiments et des autres travaux de génie civil dans le but de limiter la production et la propagation du feu et des fumées. Substances dangereuses: Aucune performance determinée. Alimentação eléctrica em edifícios e obras de engenharia civil, a fim de limitar a geração e propagação do fogo e fumo. Substâncias perigosas: Propiedade não determinada. Elektrizitätsversorgung in Gebäuden und anderen Bauwerken mit dem Ziel, die Entstehung und Ausbreitung von Feuer und Rauch zu begrenzen. Gefahrstoffe: Keine Leistung festgelegt. Manufacturer s name and registered address, or identification mark. Fire reaction performance class European standard applied as it is named in the Official Journal of the European Union (OJEU) CE marking. 11

Which standards are applicable for the CPR? UNE-EN 13501-6 Fire classification of construction products and building elements. Part 6: Classification using data obtained from reaction to fire tests on electric cables. UNE-EN 50575 Power, control and communication cables. Cables for general applications in construction works subject to reaction to fire requirements. UNE-CLC/TS 50576 Electric cables. Extended application of test results. UNE-EN 50399 Common test methods for cables under fire. Heat release and smoke production measurement on cables during flame spread test. Test apparatus, procedures, results. UNE-EN 60332-1-2 Test methods on electric and optical fibre cables under fire conditions. Part 1-2: Test for vertical flame propagation for a single insulated wire or cable. Procedure for 1 kw premixed flame. UNE-EN 61034-2 Measurement of smoke density of electric cables burning under defined conditions. Part 2: Test procedure and requirements. UNE-EN 60754-2 Tests on gases evolved during combustion of materials from cables. Part 2: Determination of acidity (by ph measurement) and conductivity. Will the CPR will be applied equally in Europe? The spirit the CPR has been created with criteria in the whole of Europe and therefore it should be applied equally in any country. Each Member State has the criterion just to decide on which of the Euroclasses will be applied to a specific product in that country. The measurement and assessment criteria will therefore be equal in each country but different Euroclasses may be established for the same product in different countries. Will the CPR bring about important modification in cables? Yes, as the assessment criteria of the CPR are more demanding than current criteria and thus will require the variation and readjustment of compounds and parameters which will make the cables be very different, even though their name does not change. The Euroclass must be marked on the sheath of the cable. 12

New EU regulation for construction materials REGULATION (EU) no. 305 2011 - CPR A ca No reaction B1 ca Very low reaction. Non-flame propagator Non-fire propagator (1.75 m) Very low heat emission B2 ca Low reaction. Non-flame propagator Non-fire propagator (1.5 m) Low heat emission Opacity Smoke a b C ca Reduced reaction. Non-flame propagator Non-fire propagator (2m) Reduced heat emission Droplets/ particles D ca Improved reaction. Non-flame propagator Improved heat emission d E ca Basic reaction. Non-flame propagator Smoke acidity F ca Undetermined Cables for every day, cables for life www.

We keep you up to date We will inform you of everything related to the new CPR on our website: www.cpr-cables.com Besides, you can download our cables Declaration of Performance through the product section on our website and access all technical documentation visiting: www. Cables for every day, cables for life

Notes 19

CPR New EU regulation for construction materials Crta. Castellón Km 226,9-50720 La Cartuja Baja - Zaragoza (Spain) T. +34 976 500 120 - info@rct.es www.