Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Similar documents
Zareba Metro Gas Detector

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Life Safety Network. Intelligent solutions for advanced requirements

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Zareba Sensepoint Pro

Operating Instructions and Maintenance Manual

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Searchpoint Optima Plus

Operating Instructions

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Sensepoint XCL Fixed Gas Detector

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Zareba Unipoint controller

System 57. An advanced world of intelligent gas detection system management

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

System 57. An advanced World of intelligent gas detection system management

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

XNX Universal Transmitter

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Touchpoint Pro Flexible Gas Control System

Sieger Apex. Flexibility that meets your requirements

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Touchpoint Plus. A whole new control experience

Operating Instructions

SPM Flex Chemcassette Tape-Based Gas Detector

Fixed-Point Industrial Gas Detection

Honeywell Analytics. Order List BW Clip & IntelliDoX

OLC(T) 100 FIXED GAS DETECTOR

Touchpoint Plus. A whole new control experience

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

MeshGuard and MeshGuard Gamma

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

MeshGuard and MeshGuard Gamma

Zareba System Overview

Neotronics Impact & Impact Pro

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Technical Manual. Zareba Sensepoint Gas Detectors

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Fixed-Point Industrial Gas Detection

Zareba fixed gas detection. Flexible, low cost fixed-point gas detection solutions

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

XNX Universal Transmitter

Gas Detection. Touchpoint Plus. A whole new control experience

3M Oldham OLCT 100. Description. Fixed Gas Detector

Two-Channel Gas Controller

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. Cost savings on wiring installation

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

SPECIFICATION MODEL 5200 GAS MONITOR SYSTEM. User Instructions For The Model 5200 Gas Monitor System

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

ULTIMA XL/XT Series Gas Monitors. [ Ultimate Features Extreme Design ]

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

5 Operating Modes GX Smallest 6 gas sample draw PID library of over 600 VOC s 2 Interchangable smart sensor slots

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

ALTAIR 5X Multigas Detector Product Specification

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

MX43. Analog and digital controller. 4 or 8 lines / 16 to 32 detectors max. Highly versatile controller. SIL1 reliability. Gas Detection Control Panel

EC FX NH3. A new and improved approach to ammonia gas detection

NATURAL GAS DETECTOR. Confined Space Monitor. Leak Investigation. Line Purge Testing. Bar Hole Sampling

EXAMPLES OF HOW TO ORDER

Carbon Monoxide (CO) Gas Detector March 15 GCO 300

Digital Gas Transmitters with Auxiliary Inputs & Control. PolyGard 2 DC6

Warranty Registration

Xgard. Fixed detectors For flammable, toxic or oxygen gases

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

OLCT 10N. Digital Gas Detector. User Manual. The Fixed Gas Detection Experts. Part Number: NPO10NEN Version: G.1

BX444-Mc Gas Detector

Confined Space Monitoring. Leak Investigation. Functions 4. Bar Hole Sampling. Line Purge Testing. Actual Size GX-2012

COSTER. Code Internal Alarm Pre-alarm Suitable sensor threshold threshold external sensor

Toxic Gas Detection. Model F12. Toxic Gas Detection

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Transcription:

Metro Gas Detector The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Metro Gas Detector One-Stop Shop Flammable and toxic gas monitors available Methane, LNG and LPG (0-100%LEL) Carbon Monoxide (0-300ppm) Nitrogen Dioxide (0-10ppm) Proven Sensor Technology Surecell ltm electrochemical sensors Poison resistant catalytic bead Fast and reliable Typical 2 to 5 year operational life Fully Configurable Four alarm levels (instantaneous or time weighted) Local relay for local control Built in audible alarm if required Status indication via LED Self test push-button User Friendly Plug-in detector and base configuration Non-intrusive, one-man operation Infrared remote control configuration Data download to controller for easy set up of inputs Cost Effective Low detector cost Mounting base and vandal proof guard included as standard Fully serviceable to minimise long term costs Minimal training required Easy to Specify Up to 125 detectors per 1km (3000 feet) of cable No booster supplies required Fully user configurable Easy to Install Industry standard cable used for installation Mounting base included Plug-in detector provides easy access to terminals Three-way termination for in, out and spur The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards commonly found in car parks, tunnels or other areas where automotive vehicles may operate. Leaks from fuel lines may include flammable materials such as LPG or petrol, while exhaust fumes contain Carbon Monoxide and Oxides of Nitrogen that are toxic. The Metro system comprising multiple detectors and controller is designed to protect people from such hazards while minimizing building running costs through economical control of ventilation systems. The Metro gas detector offers simple and low cost installation. The mounting base is fixed into position without the detector fitted, thereby offering unhindered access to terminals for the installer. 5 x 1mm 2 (17AWG) screened cable can be terminated at each base with terminals for cable in, out and spur. Once all cabling is complete, the detector simply plugs into the base and is secured into position via two screws. Every detector is supplied complete with one of two types of vandal proof guard, flush or surface mount. Set up and configuration could not be easier. Each detector is configured using the ZHC2 infrared remote control (supplied with each controller). Configurable options include gas type, address, four alarm set points (instantaneous or time weighted action), local relay (trip point, energised/de-energised operation, NO/NC link selectable), local audible alarm operation (active or disabled) and calibration (see specification table for applicable ranges). The ZHC2 saves each detector setting for download to the controller, thereby configuring all controller inputs quickly and easily. Reliable operation and ease of maintenance played a key part in the design of the Metro detector. Trouble free long life can be expected using Honeywell Analytics patented Surecell TM electrochemical toxic sensor technology and poison resistant catalytic bead flammable sensors. Detectors are serviceable to reduce on-going costs to an absolute minimum. With each controller capable of powering up to 250 toxic, 125 flammable or 80 toxic and flammable detectors, without the need for booster power supplies, a Metro system is sure to offer installers and end users the lowest cost and safest gas monitoring solution on the market today.

Installation details Overview The Metro Detector is designed to simplify installation and minimise costs wherever possible. Each detector is supplied with mounting base, vandal proof guard and gas identification labels as standard. Detector bases should be mounted to conduit box with suitable cable glands for strain relief. Detector audible alarm may be inhibited via ZHC2 IR Remote Control. Visual indication may be masked via gas type label (supplied). Dimensions shown exclude the vandal proof guard. Mechanical Arrangement View Without Protective Cover 102mm (4") Base With Protective Cover 50mm (2") Electrical Connections From Metro Controller FE L N S+ S- FE L N S+ S- FE L N S+ S- Screen To Next Detector FE L N S+ S- Cable Type 5 core, AC rated, 1mm 2 minimum with overall screen

Technical summary Vandal Proof Guard (Flush Mounting) General Specification Use Detectable Gases Addressable gas monitor for use with dedicated Metro control system to detect flammable and toxic gases commonly found where automotive vehicles are in operation. Applicable to, but not limited to, car parks, tunnels, loading bays, warehouses or similar. Suitable for use in non-explosive atmospheres only. Gas (F)lammable (C)arbon Monoxide (N)itrogen Dioxide Standard Range (1) 0-100%LEL Propane 0-300ppm 0-10ppm Alternate Range (2) 0-100%LEL C1 to C5 0-500ppm N/a Alarm 1* 10%LEL 35ppm 2ppm Alarm 2* 20%LEL 80ppm 5ppm Alarm 3* N/a 100ppm N/a Alarm 4* N/a 120ppm N/a *All factory set alarms are instantaneous i.e. time weighted function is disabled. Instantaneous alarm response time 33 seconds (maximum). Time weighted alarms may be set from 1 minute to 8 hours. Alarms may be set between 10% and 90% of full scale. Overall diameter: 218mm (8.6 ) Overall height: 84mm (3.3 ) Vandal Proof Guard (Surface Mounting) Overall diameter: 218mm (8.6 ) Overall height: 120mm (4.7 ) Conduit boxes should be sourced separately subject to site installation requirements. Interface Status Indication Self Test Push Button Configuration Electrical Safety General Recommended Cable Relay Construction Material Dimensions Weight Approvals Environmental IP Rating Operating Temperature Operating Humidity Operating Storage Conditions Local audible alarm rated 75dB at 1m (3 feet) (may be user disabled). Tri-coloured, ultra-bright LED indicating warm up (steady green), system healthy (flashing green), gas alarm (flashing red) or detector fault (flashing amber). May be masked from view via gas type label supplied. Status indicator doubles as self-test push button to enable local self test of audible alarm, visual indicator and sensor circuit. No executive outputs are activated during self-test operation. ZHC2 infrared remote control (supplied with Metro controller) enables user configuration of gas type, address, alarm set points (instantaneous or time weighted), zero and span calibration, activation of audible alarm and relay set up Complies with IEC/EN 61010 Electrical Safety. Designated Class II, Pollution Degree 2 (double insulated) not requiring an electrical safety earth 5 wire connection 2 x power, 2 x digital communications, 1 x functional earth Power: 85-265Vac, 50/60Hz auto-sensing (flammable 8VA, toxic 4.8VA) Communications: Pulse width modulated for improved protection from RFI 5 core screened, 1mm 2 (17AWG) minimum, 300/500v rating, meeting isolation voltage requirements for Protection by Double Insulation 2kV (2350v) 1 x NO/NC (link selectable) rated 1A, 30VDC (non inductive load) Configurable as disabled or trip at alarm level 1 to 4, normally energised or de-energised Detector: ABS (UL94V0). All PCBs conformal coated Vandal Proof Guard: Polyurethane coated mild steel Refer to diagrams Detector: 0.45kg (1lb) Vandal Proof Guard: flush mounting 0.65kg (1.4lbs), surface mounting 0.8kg (1.8lbs) CE, EMC (EN50270), Electrical Safety IEC/EN61010 Designed to meet NEN2443 and VDI2053. Contact Honeywell Analytics for latest information For use indoor only, IP2X in accordance with EN60529:1992-20 C to +40 C (-4 F to 104 F) Continuous 20-80%RH (non condensing) Intermittent 10-90%RH (non condensing) 90-110kPa -20 C to +25 C (-4 F to 77 F) 20-80%RH (non condensing)

Ordering information Ordering Information Standard Supply Part Number MDF1S MDF1F MDC1S MDC1F MDN1S MDN1F Shipping Details Each detector is supplied 100% inspected and tested prior to despatch from the factory complete with certificate of conformity, mounting base, vandal proof guard, instruction leaflet and spare gas type label Description Metro flammable gas detector (0-100% LEL Propane) c/w surface mount guard Metro flammable gas detector (0-100% LEL Propane) c/w flush mount guard Metro CO gas detector (0-300ppm) c/w surface mount guard Metro CO gas detector (0-300ppm) c/w flush mount guard Metro NO 2 gas detector (0-10ppm) c/w surface mount guard Metro NO 2 gas detector (0-10ppm) c/w flush mount guard Detector: Shipping carton: 220mm x 205mm x 83mm (8.7" x 9.1" x 3.7") Gross weight: 0.6kg (1.3lbs) Vandal Proof Guard (Flush Mounting): Shipping carton: 222mm x 207mm x 120mm (8.7" x 8.1" x 4.7") Gross weight: 0.8kg (1.8lbs) Vandal Proof Guard (Surface Mounting): Shipping carton: 222mm x 207mm x 183mm (8.7" x 8.1" x 7.2") Gross weight: 1kg (2.2lbs) Calibration Equipment MDCC Calibration cup for detector ZCALREG1 Pre-set 0.3l/m flow regulator SPPPTUB 1m Tygon tubing (suitable for all gases) 2302D0765 Carry case for 2 x 2AL gas cylinders, regulators, tubing Calibration Gases Contact Honeywell Analytics representative

Our Product Range Fixed Gas Monitoring Honeywell Analytics offers a wide range of fixed gas detection solutions for a diverse array of industries and applications including: Commercial properties, industrial applications, semiconductor manufacturers, energy plants and petrochemical sites. Detection of flammable, oxygen and toxic gases (including exotics) Innovative use of 4 core sensing technologies paper tape, electrochemical cell, catalytic bead and infrared Capability to detect down to Parts Per Billion (ppb) or Percent by Volume (%v/v) Cost effective regulatory compliance solutions Portable Gas Monitoring When it comes to personal protection from gas hazards, Honeywell Analytics has a wide range of reliable solutions ideally suited for use in confined or enclosed spaces. These include: Detection of flammable, oxygen and toxic gases Single gas personal monitors worn by the individual Multi-gas portable gas monitors used for confined space entry and regulatory compliance Multi-gas transportable monitors used for temporary protection of area during site construction and maintenance activities Technical Services At Honeywell Analytics, we believe in the value of great service and customer care. Our key commitment is providing complete and total customer satisfaction. Here are just a few of the services we can offer: Full technical support Expert team on hand to answer questions and queries Fully equipped workshops to ensure quick turnaround on repairs Comprehensive service engineer network Training on product use and maintenance Mobile calibration service Customised programmes of preventative/corrective maintenance Extended warranties on products Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Europe, Middle East, Africa Life Safety Distribution AG Wilstrasse 11-U31 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com Americas Honeywell Analytics Distribution, Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8208 detectgas@honeywell.com Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (1) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 0329 analytics.ap@honeywell.com Technical Services ha.emea.service@honeywell.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_Metro Detector_DS0329_V4_EMEA 09/07 2007 Honeywell Analytics 11135