Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Similar documents
Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Zareba Sensepoint Pro

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

XNX Universal Transmitter

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Searchpoint Optima Plus

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

EC FX NH3. A new and improved approach to ammonia gas detection

Fixed-Point Industrial Gas Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Operating Instructions

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

Zareba Metro Gas Detector

Fixed-Point Industrial Gas Detection

Life Safety Network. Intelligent solutions for advanced requirements

XNX Universal Transmitter

Operating Instructions and Maintenance Manual

System 57. An advanced World of intelligent gas detection system management

Sensepoint XCL Fixed Gas Detector

System 57. An advanced world of intelligent gas detection system management

Technical Manual. Sensepoint XCD Gas Detector PRE-LAUNCH

Sieger Apex. Flexibility that meets your requirements

OLC(T) 100 FIXED GAS DETECTOR

Technical Manual. Sensepoint XCD Gas Detector

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Certifications. The Fixed Gas Detection People

Searchpoint Optima Plus

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Detection of explosive gases, toxic gases or oxygen. Infrared XP version. SIL 2 high reliability IP 66. Aluminium or Stainless Steel version

Zareba Unipoint controller

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

SPM Flex Chemcassette Tape-Based Gas Detector

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

XNX Universal Transmitter

3M Oldham OLCT 100. Description. Fixed Gas Detector

Gas Detection. Touchpoint Plus. A whole new control experience

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Dräger Polytron 5720 IR Toxic Gas Detection

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

3years. Detection of explosive gases, toxic gases and oxygen. Infrared XP IR version. SIL 2 high reliability IP 66.

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Operating Instructions

Sieger fixed gas detection. Fixed protection from hazardous gas

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Honeywell Analytics. Order List BW Clip & IntelliDoX

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

OLCT 100 DETECTION DE GAZ FIXE. Certifications. Better detection. Better protection. Detection of Combustible, Toxic or Oxygen gases

Dräger Polytron 8310 IR Detection of flammable gases and vapour

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

Dräger Polytron 5720 IR Detection of carbon dioxide

Dräger Polytron 8720 IR Detection of carbon dioxide

Touchpoint Pro Flexible Gas Control System

Dräger Polytron 8000 Stationary gas detector (EC)

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Technical Manual. Zareba Sensepoint Gas Detectors

Dräger Polytron 8700 IR Detection of flammable gases and vapors

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIL 2. Ultima X Series Gas Monitors CERTIFIED

MeshGuard and MeshGuard Gamma

Zareba System Overview

Sensepoint XCD RTD (Remote Toxic Detector) Technical Manual

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

REMOTE TOXIC, COMBUSTIBLE, AND OXYGEN GAS SENSORS WITH LOCAL DIGITAL DISPLAY

Dräger Polytron 5100 EC Detection of toxic gases and vapors

Lumidor portable gas detection. Portable protection from hazardous gas

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

S5000 Gas Monitor. GMS5000.com

TXgard-Plus. Flameproof Toxic and Oxygen Gas Detector with Non-intrusive One-man Calibration. Installation, Operation and Maintenance Instructions

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron 8100 EC Detection of toxic gases and vapors

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

Dräger Polytron 8000 Stationary gas detector (EC)

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

EXAMPLES OF HOW TO ORDER

Xgard. Fixed detectors For flammable, toxic or oxygen gases

SPM Flex Chemcassette Tape-Based Gas Detector

Touchpoint Plus. A whole new control experience

PHD6. Flexible, comprehensive monitoring backed up by high performance functionality

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Transcription:

Sensepoint XCD Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Sensepoint XCD Common transmitter platform Same transmitter structure applicable to a variety of new and existing gas sensors Local/remote sensor capability Uses ECC/Catalytic/IR sensing technology Smart intelligence recognises sensor type & range Clear and informative display Tri-colour backlight on LCD display Instantly and clearly visible from a distance Helps to clarify operation status in adverse situations Multiple signal outputs 4 to 20mA standard Switching relays Modbus Surecell TM and Reflex TM Superior performance sensing technology Increased accuracy and reliability Determines the health of O2 and toxic cells Detects dry-out of the sensor cell Ensures highest level of up-time Infrared sensing technology Low cost IR solution Longer service life No poisons Doesn t need oxygen The Sensepoint XCD (Exceed) range of fixed gas detectors is used to monitor areas where flammable, oxygen deficiency and toxic gases may pose a hazard to working environments. Incorporating all the advantages of leading edge, fixed industrial gas detection technology, XCD offers high performance and reliability synonymous with the Honeywell brand. XCD is designed for a broad spectrum of industrial applications with a comprehensive choice of features and benefits in a truly cost effective package. This advanced and versatile range of gas detectors monitors and indicates the presence of any one of many toxic and flammable gases. Any user can instantly identify the operating status of XCD via its clear multi-function backlit display. Output signals available are industrial standard 4 to 20mA, relay contacts and MODBUS. Routine maintenance, diagnostics and options to customize XCD factory defaults can be achieved without opening the unit. Sensepoint XCD uses a number of patented sensing technologies in its core design which reflect over 40 years of global experience associated with the famous Sieger name. These include poison resistant catalytic bead for flammable gases and electrochemical cell for toxic gases. Non-dispersed Infrared (NDIR) technology is available to those users who require more robust detection with longer sensor operating lifetime. As a result, XCD is suitable for many light and heavy industries. In addition, the design of XCD reflects outstanding performance, whether it is used in harsh outdoor environments or sheltered indoor applications. Non-intrusive operation Easy routine maintenance No need to open the transmitter Faster planned maintenance Greater operator confidence Housing material options Aluminium alloy Stainless Steel 316 Easy to install Simple plug-in sensors Integral plate for wall mount Separate kit for vertical/horizontal pipe mount On board relays allow for local alarms 3 wire operation, source or sink Worldwide certifications IEC, ATEX UL, CSA KTL, GB Applications RMAL FAULT Petrochemical plants Oil refineries Chemical manufacturing Offshore exploration and production Power generation plants Fertilizer manufacturing Natural gas distrition Steel plants Waste water facilities Gas & Petroleum storage Plant rooms and factories Chemical stores Food & Beverage Refrigeration Vehicle manufacturing ALARM TRI-COLOUR BACKLIGHT ON LCD DISPLAY, INSTANTLY AND CLEARLY VISIBLE FROM A DISTANCE Sensepoint XCD will automatically alert the operator to its functional status. Normal operation will be indicated by a steady GREEN backlit display. A flashing RED backlit display will alert the operator to a Gas Alarm. A Fault condition from the XCD will be indicated by a flashing YELLOW backlit display.

Installation Mechanical Installation options 164 [6.457] 17 [0.669] 106 [4.173] 225 [8.858] 10 [0.402] 13 [0.492] 99 [3.898] 164 [6.457] 80 [3.150] Horizontal Pipe Mounting 80 [3.150] Vertical Pipe Mounting Terminal connections 1 2 3 13 14 15 106 [4.173] Ø38~95 [Ø1.5~3] 130 [5.118] Sensepoint XCD is designed for use in potentially explosive atmospheres. As such, installation should follow national guidelines using suitable mechanically protected cable and glands (M20 or ¾ NPT) or conduit. Use 0.5mm2 (20AWG) to 2.5mm2 (~13AWG) cross sectional area cable as needed to ensure minimum operating voltage at the detector, depending on installed cable length. Various accessories are available for different applications. 4-M8 Bolt 4-Ø8.50 HOLE Wall Mounting Optional mounting NC RLY1 COM 4~20mA COM RLY2 TxD Digital RxD Comm NC COM NC RLY3 COM 4 5 6 7 8 9 10 11 12 Terminal Connection Discription 4~20mA Power (16~32VDC) Ground Current Output Signal Controller Connections COM TxD RxD RLY1/NC RLY1/COM RLY1/ RLY2/NC Comm. Ground Data+ DataNormally Closed Common Normally Open Normally Closed RLY2/COM Common (Default A2) RLY2/ RLY3/NC RLY3/COM RLY3/ Normally Open Normally Closed Common Normally Open Programmable Relay 3 (Default Fault) RS485 MODBUS RTU Programmable Relay 1 (Default A1) Programmable Relay 2 Duct Mounting Terminal Module Transmitter wiring Typical maximum installed cable lengths The Sensepoint XCD transmitter may be wired in either Current SOURCE or Current SINK configuration. These two options are offered to allow greater flexibility in the type of control system that it can be used with. SOURCE/SINK is selectable via the switch located on the back side of the display module; accessible by removing the display module during installation/commissioning. The Sensepoint XCD transmitter requires a power supply from the controller of between 16Vdc and 32Vdc. Ensure that a minimum supply of 16Vdc is measured at the sensor, taking into account the voltage drop due to cable resistance.the maximum loop resistance in the field cable is calculated as follows: R loop = (V controller V detector min) / I detector +2 + 24 Volts 4-20 ma + (wrt Controller ) Current flow 4 to 20 ma Controller 16V (min) XCD Controller Field Cable (L) RL Detector Signal 4-20mA +4V (wrt Controller ) 0 Volts (Common) Current Source Field Device The following tables shows the maximum cable distances between the controller and transmitter for different cable parameters. + 24 Volts Controller Detector 4-20 ma 4 to 20 ma Current flow RL 0 Volts (Common) Current Sink Field Device Power Connection

Specification Sensepoint XCD Transmitter Use Electrical Construction Material Weight Mounting Entries Performance Repeatability Linearity Accuracy Response Time Detectable Gases 3-wire, 4-20mA, gas detector transmitter for use with directly installed flammable and toxic gas sensors. For the protection of personnel and plant from flammable and toxic gas hazards. Input Voltage Range: 16 to 32Vdc (dc nominal) Power Consumption: Max 5 Watts Current output 4-20mA (Source or Sink) 0.0<1.0 ma Fault 4.0 ma to 20.0 ma Normal gas measurement 2.0 ma or 4.0 ma (17.4 ma) Inhibit (during configuration/user settings) 22.0 ma Maximum over range Terminals 18 x screw terminals suitable for wire diameter 0.5mm 2 (20AWG) to 2.5mm (13AWG) Relays 3 x 5A@25AC. Selectable normally open or normally closed (Terminal) and energized/de-energized (programmable) Communication RS485 Modbus (Pending) Epoxy painted Aluminium. Stainless Steel 316 (Pending) Aluminium Alloy :1.7kg. Stainless Steel 316: 2.2 kg Pole or wall mounting 2 x M20 (or 2 x ¾ NPT) field cable entries, 1 x M25 sensor entry +/- 1% of FSD +/- 1% of FSD < +/- 5% of FSD (O2, CO, H2S, FL-CAT) T50 = <10s, T90 = <25s (FL-CAT) Gas Name Selectable Span Step Default Range Acceptable Calibration Gas Range(s): Gas Range(s) Oxygen 25.0%/Vol only n/a 25.0%Vol 20.9%/Vol(Fixed) Hydrogen Sulphide 10.0 to 100.0ppm 1ppm 50ppm 30 to 70% of selected Carbon Monoxide 100 to 1000ppm 100ppm 500ppm Hydrogen 1,000ppm only n/a 1,000ppm Methane (CAT) 20,0 to 100.0%LEL 10%LEL 100.0%LEL Methane (IR) 20,0 to 100.0%LEL 10%LEL 100.0%LEL TES Performance figures are taken at 20~25 0 C, measured using a sample humidity of 50%RH, applicable between 10 and 90% of full scale, measured by test units calibrated at 50% of full scale, measured at recommended flow rate with calibration cup (SPXCDCAL). Response time (T90) may increase at lower temperature condition or at diffusion mode with weather protection (SPXCDWP). Data represents typical values, and system conditioning may be required to achieve stated result. Contact HA for details. Certification China GB Ex d IIC T4 GB3836.1&2-2000, PA CCCF (Pending) Korea KTL Ex d II C T6 (-40ºC to +65ºC) US (Pending) UL Canadian (Pending) cul/csa European ATEX Ex II 2 GD Ex d IIC Gb T6(Ta -40ºC to +65ºC) Ex tb IIIC T85 0 C Db IP66 International IEC Ex II 2 GD Ex d IIC Gb T6(Ta -40ºC to +65ºC) Ex tb IIIC T85 0 C Db IP66 EMC EN 50270 Environmental 30 to 70% of selected full scale range (Typically 50%) Carbon Dioxide (IR) 2.00%Vol only n/a 2.00%Vol 0.8 to 1.2%Vol IP Rating Operating Temperature Operating Humidity Operating Pressure Storage Conditions IP66 in accordance with EN60529:1992-40ºC to +65ºC/ -40ºF to +149ºF. Continuous 20-90%RH (non condensing), Intermittent 10-99%RH (non condensing) 90-110kPa -25 C to +65 C (-13 F to +149 F)

Common Transmitter Platform XCD Common Transmitter Platform The Sensepoint XCD uses ECC/Catalytic/IR and remote sensing technology, which are supplied pre-configured. Smart intelligence in the transmitter detects the type and range of sensor fitted. Cat Sensor: IR Sensor: ECC Sensor: RFD(Pending): RTD(Pending): Flammable Gas Flammable Gas CO2 O2 CO H2S H2 Sensepoint STD Sensepoint HT Sensepoint Toxic SO2 NH3 2 Cl2 Ordering Information Sensepoint XCD consists of transmitter and sensor. Some special sensor (RFD & Sensepoint Toxic) should be ordered separately, but standard sensor such as CAT/IR/EC sensor should be ordered with only one KIT part number. A Sensepoint XCD KIT consists of Transmitter, Sensor socket, Sensor cartridge, Standard weather protection, Magnetic wand and Allen key. Sensepoint XCD transmitter and sensor KIT SPXCDAAMFX SPXCDAAMRX SPXCDAAMO1 SPXCDAAMHX SPXCDAAMCX SPXCDAAMG1 SPXCDAAMB1 Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with Aluminium alloy, M20 Entry Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) with Aluminium alloy, M20 Entry Oxygen 25.0%/Vol with Aluminium alloy, M20 Entry Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm, 1ppm) with Aluminium alloy, M20 Entry Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) with Aluminium alloy, M20 Entry Hydrogen 0-1000ppm with Aluminium alloy, M20 Entry Carbon Dioxide IR 0-2%VOL with Aluminium alloy, M20 Entry Replacement sensor cartridge SPXCDXSFXSS SPXCDXSRXSS SPXCDXSO1SS SPXCDXSHXSS SPXCDXSCXSS SPXCDXSG1SS SPXCDXSB1SS Methane CAT 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Methane IR 0-100%LEL (20,0 to 100.0%LEL, 10%LEL) Oxygen 25.0%/Vol only Hydrogen Sulphide 0-50ppm (10.0 to 100.0ppm, 1ppm) Carbon Monoxide 0-500ppm (100 to 1000ppm, 100ppm) Hydrogen 0-1000ppm only Carbon Dioxide IR 0-2%VOL only Accessories S3KCAL SPXCDCC SPXCDDMK SPXCDHMANEN SPXCDMTBR SPXCDSDP Calibration cap Collecting cone for use with lighter than air gases Duct mounting kit Hard Copy Manual in English Pipe Mounting bracket (inc. fixings and hex wrench set) Sunshade / Deluge Protection Spares SPXCDDMT SPXCDDMF SPXCDTMO SPXCDTMT SPXCDTMF SPXCDNPTP SPXCDM20P SPXCDMANCD SPXCDNADP SPXCDWP SPXCDMAG SPXCDSRLS SPXCDAKS SPXCDHWES SPXCDEBS Replacement display module (O2 & Toxic) Replacement display module (FL & IR) Replacement terminal module (O2) Replacement terminal module (Toxic) Replacement terminal module (FL & IR) 3/4 NPT Plug M20 Plug Instruction manual CD 3/4 NPT to M20 Adaptor Weather Protection Magnet Sensor Retainer with locking screw Allen key for stopper Hex wrench for earth screw Earth Bracket and Screws

Honeywell Analytics Lines of Business Commercial Vulcain-brand gas detection from standalone units to fully engineered, multi-point systems, all offering costeffective regulatory compliance» Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories Industrial Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies» Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial Portables Single or multi-gas Lumidor and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments» Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets Find out more www.honeywellanalytics.com America Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8208 detectgas@honeywell.com Europe, Middle East, Africa, India Life Safety Distribution AG Wilstrasse 11-U31 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com High Tech/Government A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paperbased solutions (MDA Scientific) offering detection down to parts per billion» Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response Technical Services 24/7 global network includes post-sales service and Systems Integration teams» Emergency call out, service contracts, on/off-site repair, training and commissioning» Complete range of spares, consumables and accessories Asia Pacific Honeywell Analytics Asia Pacific Co. Ltd. #508, Kolon Science Valley (I) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050, Korea Tel: +82 2 2025 0307 Fax: +82 2 2025 0329 Email:analytics.ap@honeywell.com Website: www.honeywellanalytics.co.kr Technical Services AP: ha.ap.service@honeywell.com EMEA: ha.emea.service@honeywell.com US: ha.us.service@honeywell.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_SENSEPOINT XCD_DS01076_V1_HAAP 12/08 2008 Honeywell Analytics 20081