Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

Similar documents
Searchpoint Optima Plus

Sensepoint. The Sensepoint range of flammable, toxic and oxygen gas detectors offer users a low cost solution to their gas monitoring needs.

Searchpoint Optima Plus

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Sensepoint. Fit For Purpose Flammable, toxic and oxygen versions available High performance, low cost Suitable for new and retro fit applications

XNX Universal Transmitter

Ordering Information. Ordering Information. Transmitter S3KUX S3KAX

Sensepoint. Fit For Purpose Flammable, toxic and Oxygen versions available High performance, low cost Suitable for new and retro fit applications

Fixed-Point Industrial Gas Detection

Signalpoint. The Signalpoint range of flammable, toxic and Oxygen gas detectors offer users a low cost solution to their indoor gas monitoring needs

Unipoint controller. The Unipoint, a simple DIN rail mounted controller

EC FX NH3 SECONDARY HEADLINE. A new and improved approach to ammonia gas detection

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Sensepoint XCD RTD. Remotely monitor toxic gases in Class 1, Div 2 areas while reducing the maintenance, training and overall cost of gas monitoring

Operating Instructions

EC FX NH3. A new and improved approach to ammonia gas detection

Sieger fixed gas detection. Fixed protection from hazardous gas

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Fixed-Point Industrial Gas Detection

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Sieger Apex. Flexibility that meets your requirements

Application Note. Comparison of optical detection systems for Infrared (IR) Hydrocarbon gas detection

Touchpoint 4. The Touchpoint 4 controller provides protection of personnel and plant from flammable, toxic and Oxygen gas hazards

Sensepoint XCD. Flammable, toxic and oxygen. catalytic, electrochemical cell and infrared sensors.

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

Touchpoint 1. The Touchpoint 1 controller provides 24 hour protection from flammable, toxic or Oxygen gas hazards.

Life Safety Network. Intelligent solutions for advanced requirements

SPM Flex Chemcassette Tape-Based Gas Detector

Honeywell Analytics is pleased to announce the release of Version firmware software for the SPM Flex TM product line.

Operating Instructions and Maintenance Manual

Introducing gas detection so intelligent, it s as close to 100% prevention as you can get

Searchline Excel. The Searchline Excel is the World s best selling infrared open path gas detector

Touchpoint Pro Flexible Gas Control System

Zareba Sensepoint Pro

Series 3000 XPIS. 2-wire loop powered toxic and Oxygen gas detector for use in potentially explosive atmospheres

Zareba System Overview

Sensepoint XCL Fixed Gas Detector

System 57. An advanced world of intelligent gas detection system management

Metro Gas Detector. The Metro addressable gas detector enables remote monitoring of flammable and toxic gas hazards

Sensepoint XCL. Gas Detection. Fixed Gas Detector FEATURES & BENEFITS. Flexible Output Options. Visual Integration. Faster Installation

Safety Manual. XNX TM Universal Transmitter. Table of Contents SIL 2 Certificates Overview Safety Parameters

System 57. An advanced World of intelligent gas detection system management

Sieger Sensepoint. Easy to Use Factory set operation Simple to replace Minimal training required

Zareba Unipoint controller

Installation Guide and Operating Manual MAN0932_V1_ _Rev B_08-12

Gas Detection. Touchpoint Plus. A whole new control experience

Operating Instructions

XNX Universal Transmitter. A universal transmitter compatible with all Honeywell Analytics gas sensor technologies DRAFT

SPM Flex Chemcassette Tape-Based Gas Detector

Dräger PIR 3000 Detection of flammable gases and vapours

Sensepoint XCD. Flammable, toxic and oxygen deficiency gas detector using catalytic, electrochemical cell and infrared sensors.

SIMRAD GD10 IR GAS DETECTOR

Lumidor portable gas detection. Portable protection from hazardous gas

Zareba fixed gas detection. Flexible, low cost fixed-point gas detection solutions

XNX Universal Transmitter

PROTECTION THAT MAKES SENSE Bluetooth Enabled Gas Detector

Touchpoint Plus. A whole new control experience

Dew-Point Transmitters and Instruments

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Honeywell Analytics. Order List BW Clip & IntelliDoX

Unipoint Controller. The Unipoint, a simple DIN rail mounted controller

Dräger Polytron Pulsar 2 Open Path Gas Detector

SafEye OPEN-PATH GAS DETECTION SYSTEM XENON 700. We INVENTED it... We PERFECTED it! Patent No. US 5,281,816; US 6,061,141; EP

Satellite XT. Analog or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

Technical Manual. LeakFilm 5. 5 Channel Conductive Liquid Leak Detection Controller

Satellite XT. Analogue or digital Point-of-Use gas detection transmitter to detect toxic, corrosive and combustible gases

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

SIMRAD GD10P - IR GAS DETECTOR OPERATING MANUAL

Neotronics portable gas detection. Portable protection from hazardous gas

Touchpoint Plus. A whole new control experience

Dräger Polytron Pulsar 2 Detection of flammable gases and vapours

Zareba Metro Gas Detector

SAFEYE XENON 700. Hydrocarbons and ethylene detection. Heated optics. 10-year Warranty for the Xenon flash bulb. SIL 2 according to IEC 61508

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

SIMRAD GD10PE IR GAS DETECTOR

Fixed Range. Fixed Gas Detection Equipment. Field mounted gas detection. solutions for the protection of. plant and personnel

MeshGuard and MeshGuard Gamma

Product Specifications

SIL 2. Ultima X Series Gas Monitors CERTIFIED

Recalibrate the way you look at gas detection

Products and performance

Gas Detection. MeshGuard RAE Systems by Honeywell Battery-Powered Wireless Gas Detector

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Gas Detection. ConneXt Loneworker Real-time visibility on the safety, location and productivity of your isolated workers

Technical Manual. LeakFilm Pro. Single Channel Conductive and Chemical Liquid Leak Detection Controller with Leak Location Detection

Danfoss gas detection unit Type GD Heavy Duty

Sensepoint XCD RTD. A gas transmitter for use with directly or remotely mounted toxic and Oxygen gas sensors

MeshGuard and MeshGuard Gamma

Dräger GS01 (wireless) Detection of flammable gases and vapours

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Detectors-Transmitters for Flammable, Toxic Gases and Oxygen. Non-intrusive operation via intrinsically safe infrared remote control.

Midas. Gas monitoring system for fast and reliable detection of flammable and toxic gases used in industrial manufacturing processes

Fixed Gas Detection Equipment

Operating Instructions

Danfoss gas detection units

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Dräger Polytron 8700 IR Detection of flammable gases and vapors

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

XNX Universal Transmitter

Transcription:

Technical Summary Searchpoint Optima Plus Specification Output Measuring range Inhibit Warning Fault Over range 4-20 ma sink or source, (Default current source) 1-3 ma (Default 2 ma) 0-4 ma (Default 4 ma) 0 ma 20-21.5 ma (Default 21 ma) Digital Output Optional Multidrop Modbus RS485 (via DVC/DX100(m)) Material 316 stainless steel Weight 1.6 kg Accuracy Optima PLUS (HC) Baseline < ±1% LEL, 50% FSD <±2% LEL Optima PLUS (ET) Baseline < ±2% LEL, 50% FSD <±3% LEL Repeatability < ±2% LEL at LEL 50% FSD Linearity < 5% FSD Response time T50 < 4.5 seconds, T90 < 6.5 seconds (for methane, including weather protection) Operational and certified -40 C to +65 C temperature range Drift with time and over -40 C to +65 C temperature range Baseline < ±2% LEL 50% FSD < ±4% LEL Drift with pressure 0.1% (of reading) per mbar Power supply 18-32 V (24 V nom) DC, < 4.5 W max Environmental protection IP 66/67 Diagnostics Via certified Hand Held Interrogator (and re-calibration) Safety approvals CENELEC (BASEEFA), SAA II 2 G EEx d IIC T5 (T amb -40 C to +55 C) T4 (T amb -40 C to +65 C) UL/CSA Class 1, Div 1, groups B, C, and D (-40 C to +65 C) FTZU, BKI, GOST Performance approvals FM, DMT EN50054, CSA C22.2 152. EMC compliance EN 50270 Installation Options 1 2 3 4 Hazardous Area Safe Area Hazardous Area Safe Area Hazardous Area Safe Area Hazardous Area Safe Area Power Controller Controller Controller DCS/PLC Modbus Modbus Modbus SCADA HWA6037 H_Searchpoint Optima Plus_DS0276_V3.indd 1 8/19/2008 11:01:49 AM

Honeywell Analytics Lines of Business Vulcain-brand gas detection from standalone units to fully engineered, multipoint systems, all offering cost-effective regulatory compliance» Applications: parking structures, chillers, mechanical rooms, office towers, commercial buildings, shopping centers, swimming pools, golf courses, schools and universities, laboratories Find out more www.honeywellanalytics.com Contact Honeywell Analytics: Americas Honeywell Analytics Inc. 405 Barclay Blvd. Lincolnshire, IL 60069 USA Tel: +1 847 955 8200 Toll free: +1 800 538 0363 Fax: +1 847 955 8210 detectgas@honeywell.com Technical Services ha.us.service@honeywell.com Industrial Renowned Sieger and Manning gas detection systems with advanced electrochemical, infrared and open path sensing technologies» Applications: oil and gas, cold storage, water/wastewater treatment, chemicals, engine rooms, plastics and fibers, agriculture, printing and light industrial High Tech/Government A complete portfolio of gas and chemical detection instrumentation including infrared spectroscopy (MST) with no cross interference, to Chemcassette paperbased solutions (MDA Scientific) offering detection down to parts per billion» Applications: semiconductor manufacturing and nanotechnology, aerospace propulsion and safety, specialty chemicals industry, research laboratories, emergency response europe, Middle east, Africa Life Safety Distribution AG Wilstrasse 11-U31 CH-8610 Uster Switzerland Tel: +41 (0)44 943 4300 Fax: +41 (0)44 943 4398 gasdetection@honeywell.com www.honeywell.com Please Note: While every effort has been made to ensure accuracy in this publication, no responsibility can be accepted for errors or omissions. Data may change, as well as legislation, and you are strongly advised to obtain copies of the most recently issued regulations, standards, and guidelines. This publication is not intended to form the basis of a contract. H_Searchpoint Optima Plus_DS0276_V3 2/08 2008 Honeywell Analytics HWA6037 H_Searchpoint Optima Plus_DS0276_V3.indd 2 Portables Single or multi-gas Lumidor and other premium detectors with compact, lightweight designs ranging from simple alarm only units to advanced, fully configurable and serviceable instruments» Applications: underground utility and electricity ducts, boiler rooms, post-fire sites, sewers, industrial plants, industrial hygiene, first responder teams, remote fleets Technical Services 24/7 global network includes post-sales service and Systems Integration teams» Emergency call out, service contracts, on/off-site repair, training and commissioning» Complete range of spares, consumables and accessories Asia Pacific Honeywell Analytics Asia Pacific #508, Kolon Science Valley (I) 187-10 Guro-Dong, Guro-Gu Seoul, 152-050 Korea Tel: +82 (0)2 2025 0307 Fax: +82 (0)2 2025 0329 analytics.ap@honeywell.com HWA6037 Commercial 8/19/2008 11:01:57 AM

Sieger Searchpoint Optima Plus Advanced infrared point gas detector HWA6037 H_Searchpoint Optima Plus_DS0276_V3.indd 3 8/19/2008 11:01:59 AM

Sieger Searchpoint Optima Plus Searchpoint Optima Plus Incorporates: The proven strengths of the original Searchpoint OPTIMA design Experience gained from over 30,000 units installed worldwide The latest technology and techniques used to develop the successful Sieger open path gas detector, the Searchline Excel Improved reliability Why Infrared? Failsafe operation Fast speed of response Reduced routine maintenance Immune to catalytic poisons Long operating life Works in inert atmospheres Why Searchpoint Optima? Can detect a wide range of hydrocarbon gases including solvents Increased reliability with no moving parts Increased stability from self compensating optics Immune to long term component drift Remote functional gas test facility Certified for North American and European Hazardous areas Why Searchpoint Optima Plus? Increased false alarm rejection with 4 2 SOFTWARE Increased uptime with contaminated optics warning Dynamic Heating Control ensures condensation free optics No undetected failures Improved diagnostics Integral event logging Reduced power consumption Certified to many hazardous area classification schemes including: European (ATEX), UL, CSA and more For over 40 years the Sieger name has been a world leader in the design and manufacture of gas detection instrumentation. As part of the Honeywell Analytics group, Sieger continues to develop advanced and innovative sensing technology, to create highly reliable, fit for purpose, cost effective gas detection solutions for the most demanding of environments. Experience in the design, manufacture, installation and maintenance of point infrared gas detection has resulted in a worldwide installed base of over 30,000 units operating from light industrial to the most demanding of offshore petrochemical applications. This expertise has resulted in Honeywell Analytics offering a new dimension in the supply of reliable infrared point gas detection with the release of the Sieger Searchpoint OPTIMA PLUS. Typical Applications Offshore oil and gas platforms, Floating Production Storage and Offloading (FPSO) vessels, Tankers, Onshore oil and gas terminals, Refineries, LNG/LPG bottling plants, Gas compressor/metering stations, Gas turbine power plants, Solvent printing and coating plants, Distilleries. Over 100 gas and vapor calibrations available. For a list of gases and vapors which Searchpoint OPTIMA PLUS can detect, contact your local representative. HWA6037 H_Searchpoint Optima Plus_DS0276_V3.indd 4 8/19/2008 11:02:00 AM

Failsafe flammable gas detection plus 2 software 1. 4. 2. 3. Sunshade / Deluge Protection This multi-purpose accessory supplied as standard shields Searchpoint OPTIMA PLUS from the extremes of operational environments ensuring reliable operation. Storm Baffle This optional baffle reduces wind chill, salt and dust build-up in exposed applications subjected to high wind speeds e.g. Offshore HVAC intakes and FPSO turrets etc. Standard Weather Protection This accessory supplied as standard, offers the best compromise between water/dust ingress and speed of response. Dust Barrier This optional barrier fitted inside the standard weather protection provides additional protection against the ingress of dust and contamination entering the optical path. Gassing Cap The gassing cap enables confidence checking of the Searchpoint OPTIMA PLUS. It provides a close fit onto the standard weather protection and can be installed without the use of any special tools. HWA6037 H_Searchpoint Optima Plus_DS0276_V3.indd 5 1. Optics Block The 4-channel (dual compensated) optics-block is the heart of the Searchpoint OPTIMA PLUS. It is specifically designed to compensate for changes in the external environment similar to 2-channel designs, but also compensates for long term component drift such as infrared sources and detectors. This combined with the de-focussed beam provides the Searchpoint OPTIMA PLUS with the most stable optics design possible. 2. Microprocessor Including 42 Software The microprocessor controls the operation of the Searchpoint OPTIMA PLUS. New 42 SOFTWARE signal processing and algorithms provide a new dimension in false alarm rejection delivering the highest level of operational integrity. 3. Heated Optics Plus Dynamic Heating Control Heated optic components, monitored via smart electronics, eliminate condensation build up with power saving features. 4. Remote Gassing Cell Permanent fitting of this optional gassing cell within the optical path allows the remote injection of functional test gas to validate the performance of a Searchpoint OPTIMA PLUS. Remote Gas Sampling Systems For monitoring remote or inaccessible locations Searchpoint OPTIMA PLUS can be fitted with a flow housing and engineered into a gas sampling system. Single-point and multi-point systems are available for both hazardous and non-hazardous areas. 8/19/2008 11:02:03 AM

Accessories Termination / Mounting Field Interrogation DVC/DX-100(I) Multi Purpose Hand Held Interrogator (Hhi) These hazardous area certified enclosures are used to terminate Searchpoint OPTIMA PLUS field cabling and provides an interface for the Hand Held Interrogator (HHI) via an intrinsically safe connection socket. This provides in-situ one-man maintenance without the need for a hot work permit. Used in conjunction with a remote gas test point this provides the best solution for checking sensors in remote locations. This versatile commissioning /maintenance tool is certified for hazardous areas and used to reconfigure Searchpoint OPTIMA PLUS for different gases and fault diagnostics. The same interrogator can be used with the original Searchpoint OPTIMA and Searchline Excel (open path gas detector) reducing operator training. DVC/DX-100(M) Modbus Interface Module Shc-1 Protection Device Provides a multi drop Modbus RS485 interface for the SEARCHPOINT OPTIMA PLUS and Searchline Excel infrared gas detection products. Reduces servicing and maintenance costs. This device provides electrical protection for the HHI when used with conventional terminal housings under a gas free permit to work system. Certified Junction Boxes A full range of hazardous area certified junction boxes are available. HWA6037 H_Searchpoint Optima Plus_DS0276_V3.indd 6 Duct Mounting Kit Analog to Bridge Converter This mounting plate arrangement enables installation of Searchpoint OPTIMA PLUS with a duct/ventilation system. It enables functional gas testing without removing the Searchpoint OPTIMA PLUS from the ducting system. This safe area DIN rail mounted item converts the analog output from a Searchpoint OPTIMA PLUS into an mv bridge output similar to that of conventional catalytic point gas detectors. This permits the use of Searchpoint OPTIMA PLUS with existing catalytic gas sensor control hardware. 8/19/2008 11:02:06 AM