Greenstar System Filter

Similar documents
CondenseSure Siphon INSTALLATION INSTRUCTIONS UK/IE GREENSTAR EXTERNAL 500ML SIPHON

INSTALLATION INSTRUCTIONS FOR FLUE KIT

GREENSTAR CAMRAY EXTERNAL & EXTERNAL SYSTEM12/18, 18/25, 25/32

GREENSTAR CAMRAY UTILITY & UTILITY SYSTEM

GREENSTAR HEATSLAVE II EXTERNAL 12/18, 18/25 & 25/32

Greenstar 12i/24i System

Greenstar 25Si/30Si USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Greenstar 12i system / 24i system

Vote for your Installer of the year at. 9/14, 14/19 & 19/24CBi. Worcester supports the Benchmark code of practice

GREENSTAR HIGHFLOW 440/550CDi

GREENSTAR HIGHFLOW 440/550CDi

Vote for your Installer of the year at HEATSLAVE

Greenstar FS 30CDi ErP & 42CDi ErP Regular

DANESMOOR 12-14, 15-19, 20-25, 26-32, 32-50, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

Greenstar 24i junior / 28i junior

Installation and servicing instructions

Installation instructions. Pump Group. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

GREENSTAR i SYSTEM USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER FOR CENTRAL HEATING SYSTEMS UK/IE (2013/08)

DANESMOOR FRONT SERVICE (FS) 12-18, FLOOR-STANDING OIL-FIRED PRESSURE-JET BOILERS USER INSTRUCTIONS & CUSTOMER CARE GUIDE

GREENSTAR HEATSLAVE II ErP+ 12/18, 18/25 & 25/32


24CDi, 28CDi & 35CDi II COMBI

GREENSTAR CDi WALL HUNG RSF GAS-FIRED CONDENSING COMBINATION BOILER

Greenstar Xtra. Installation instructions. Passive flue gas heat recovery device. For use with Greenstar CDi Compact, Si Compact and i combi boilers

WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER GREENSTAR 24i Junior/28i Junior

USER INSTRUCTIONS & CUSTOMER CARE GUIDE HIGHFLOW 400 ELECTRONIC SERIES

PRODUCT GUIDE. High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic.

WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER

GREENSTAR Ri USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING REGULAR BOILER FOR CENTRAL HEATING SYSTEMS a (2010/10)

Power flushing and protecting your heating system can increase efficiency by at least 25%.

CalMag Filter Installation Instructions

GREENSTAR i JUNIOR USER INSTRUCTIONS UK/IE WALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILER

GREENSTAR Ri ErP. User instructions UK/IE. Wall hung RSF gas fired condensing regular boiler. For central heating systems

Boiler protection kit guide

Eliminator TotalGuard Installation Manual

PERFORMANCE SHOWER PRODUCTS

HEAVY DUTY BRASS SHOWER PUMPS

GREENSTAR Ri ErP + User instructions UK/IE. Wall hung RSF gas fired condensing regular appliance. For central heating systems

DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

GREENSTAR CDi CLASSIC REGULAR ErP

RT 10 RT 10 INSTALLATION, USER INSTRUCTIONS & CUSTOMER CARE GUIDE. Order no

Operating instructions

Bosch EasyControl. Smart heating and hot water control made Easy

CalMag Heating Pack Installation Instructions

FR 10 INSTALLATION & USER INSTRUCTIONS INTELLIGENT ROOM THERMOSTAT

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

Greenstar Si Compact ErP

Bath Shower Mixer

Bosch EasyControl. Smart heating and hot water control made Easy

Room-temperature (economy/night) unit TR 212 E

Dene Bath Shower Mixer

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Installation and Servicing Instructions. Alpha FlowSmart

INTRODUCTION STORAGE PRIOR TO INSTALLATION. Expansion Vessel Hose. Part No High Flow Rate Inlet Control Set. Part No.

For commercial & industrial systems. Large volume dirt collection capacity

Grant Vortex. Boiler House Floor Standing Condensing Oil Boiler Range User Handbook. Model shown: VTXBH3646

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Users Manual. Gas wall hung Boiler condensing Buderus /S. Please read thoroughly before operating the unit

Pear Kitchen Sink Tap

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

DIGISTAT OPTIMISER PROGRAMMABLE 7 DAY ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat

The Worcester CondenseSure. An innovative solution to prevent freezing condensate NEW

T UNI 7000 F. Operating instructions For the user (2006/05) AU/GB

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

DIGISTAT PROGRAMMABLE 24 HOUR ROOM THERMOSTAT SYSTEM. Radio frequency controlled programmable room thermostat.

POWER SHOWERS Models 4500M 5002M 4500T 5002T

Statesman 45/50L, 50/70L, 70/90L, 90/110L, Utility 50/70L, 70/90L, 90/110L, 110/130L, 130/150L

CROMO manual mixer shower

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

Thermostatic Concealed Shower Valve

Commercial product range

Pedestal Range. Installation and user manual. Kiosk. Trafalgar. Tube. Issue 001 September 2017 ENGLISH UK IRL SmithsEP.co.uk

Aqueous Thermostatic Surface Mounted Bar Shower Valve With Fast Fit Connections

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT: READ AND SAVE THESE INSTRUCTIONS FOR THE BENEFIT OF THE USER

Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

ETLW7. Product: 7kg Top Load Washing Machine. User Manual

Enzo Concealed Shower Mixing Valve

AGS 2 SOLAR PUMP STATION FOR SOLAR DOMESTIC HOT WATER SYSTEMS UK/IE

Installation & User Instructions

ASSEMBLY & OPERATING INSTRUCTIONS

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Installation Instructions Flute Tap Range

EDEN. Installation Instructions. Bath shower manual mixer tap INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER

MEGAFLO HE Iss 1

Dovre 250 Cast Iron Gas Stove

Commissioning Pack. Heating and Hot Water Heat Pumps. IMPORTANT DOCUMENTS To Be Kept At All Times. With Equipment. Accredited Ecodan Installer:

HYDRAULIC OIL COOLER. Installation, Operation & Maintenance Guide

USER INSTRUCTIONS & CUSTOMER CARE GUIDE Si II SERIES

Installation, Operating and Servicing Instructions

Blueberry Kitchen Sink Tap

METRO BASIN MONO MIXER CHR

ADVANCE ECB ELECTRIC COMBINATION BOILER

ADVANCE ELECTRIC THERMAL STORE

SEALED THERMAL STORE

Cinnamon Kitchen Sink Tap

Monza Easyfit Kitchen Sink Mixer

ELECTRONIC WATER CONDITIONERS USER GUIDE IMPORTANT READ THESE INSTRUCTIONS BEFORE FITTING

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

JANUS 3 CIRCULATOR WATER HEATER INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS G.C. No

Transcription:

Installation and Servicing Instructions Greenstar System Filter For sealed and open vented central heating systems with 22 or 28mm central heating pipes 672087500-00.Wo UK/IE 6 720 87 500 (205/07)

Contents Contents Symbols and safety precautions................. 2. Explanation of symbols..................... 2.2 Safety precautions........................ 2 2 Central heating system water................... 3 2. Protecting your heating system.............. 3 3 Standard package............................. 3. Installation location within system pipework.... 3..Dimensions.............................. 5 Installation................................... 6 5 Servicing..................................... 8 5. Spare parts............................. 0 6 Guarantee................................... 0 7 Service record............................... Symbols and safety precautions. Explanation of symbols Warning symbol Safety instructions in this document are framed and identified by a warning triangle which is printed on a grey background. Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. NOTICE: indicates possible damage to property or equipment, but where there is no risk of personal injury. CAUTION: indicates possible personal injury. WARNING: indicates possible severe personal injury. DANGER: indicates possible risk to life. Important information Notes contain important information in cases where there is no risk of personal injury or material losses and are identified by the symbol shown on the left.they are bordered by horizontal lines above and below the text..2 Safety precautions Fitting and modification The unit must not be fitted in any way other than described in the Installation Instructions and any misuse or unauthorised modifications to the unit or associated components and systems could invalidate the guarantee. The manufacturer accepts no liability arising from any such actions. This does not affect your statutory rights. Health and safety The appliance contains no substances that contravene the COSHH Regulations (Control of Substances Hazardous to Health regulations 988). CAUTION: The system filter contains a strong magnet. 2 Greenstar System Filter 672087500 (205/07)

Central heating system water 2 Central heating system water 2. Protecting your heating system Unnecessary breakdowns Contaminated central heating system water can cause pumps, heat exchangers and valves to block. The contamination can also cause radiator cold spots that will reduce the effectivity of that radiator and even cause the radiator to corrode from the inside, resulting in leaks. System filter function The system filter is bi-directional, this means that the central heating water can flow either way through the filter, from top to bottom or from bottom to top. The central heating system water is circulated through the filter to remove the black iron oxide sludge and other non-magnetic debris. The system water is slowed down as it circulates around the filter where a powerful magnet captures the potentially damaging iron oxide sludge, preventing it from being circulated within the system thereby protecting the heat exchanger, pump and valves, The other non-magnetic debris is captured within the traps at the top and bottom of the filter. 672087500-20.Wo Greater fuel usage and increased bills Dirty water also creates a build up of sludge that coats the inside of the radiator and the boiler heat exchanger. This sludge creates a barrier inside the radiator and effectively reduces heat from that radiator into the room. This results in your heating system working harder to overcome the layers of dirt in the system to achieve your desired room temperature. The heating system will use more fuel in an effort to reach your desired room temperature, leading to higher heating bills. Your options Every system is different and advice should be taken from your reputable heating engineer to comply with BS 7593 (Code of practice for treatment of water in central heating systems). Best practice would be to have your system drained, refilled with water and a flushing chemical. This would then be drained and flushed with clean water until the water runs completely clear. Where the filter is installed on an existing system that shows signs of magnetite contamination a chemical gravity flush of the system is required or for best practice a power flush or alternatively a MagnaCleanse flush is undertaken prior to installation To ensure that dirt does not build up again, a system filter should be fitted and a chemical inhibitor added. The system filter should be cleaned each year during the annual boiler service. Fig. System filter 672087500-2.Wo Greenstar System Filter 672087500 (205/07) 3

Standard package 3 Standard package 2 00 22mm 28mm 200 ΔP (mbar) 0 0 0 20 30 0 Volume flow rate (l/min) 672087500-29.Wo Fig. 3 Pressure drop graph 5 3 6 3. Installation location within system pipework The filter can be installed anywhere in a heating system, except between the boiler and the feed and expansion pipes on an open vent system. To maximise the effectiveness it should be placed on the primary heating return before the boiler and after the last radiator on a vertical run of pipework. In determining a suitable location for installation, it is important to ensure you allow adequate access for servicing. Fig. 2 Standard package [] Greenstar System Filter [2] Isolating valve - A (22 or 28mm) [3] Isolating valve - B (22 or 28mm) [] Valve C clips [5] Valve tool [6] Lid tool [-] Pipe cutting template [-] Installation and Servicing Instructions [-] Guarantee card [-] Label System filter fitted 672087500-9.Wo 6 7 M 3 2 OK 5 General information The Worcester Greenstar System Filter incorporates a powerful internal magnet with a cyclonic trap that removes both magnetic and non-magnetic particles. The system filter can be installed on heating systems with either a 22 or 28mm diameter return pipe providing there is sufficient residual pump head to overcome the hydraulic resistance at higher flow rates (see graph in figure 3). The system should be flushed and a suitable inhibitor added in accordance with BS7593 before installing the Greenstar System Filter. Failure to comply with the guidance will limit the effectiveness of the Greenstar System Filter in protecting your boiler and central heating system. Open vented system Fig. Open vented system [] Boiler [2] Open vent tank [3] Pump [] Radiator [5] System filter [6] Cylinder [7] Diverter valve [ ] Optimum location [OK] Suitable location [ ] Unsuitable location 672087500-26.Wo Greenstar System Filter 672087500 (205/07)

Standard package 6 3.. Dimensions 22mm System filter 80 0 9.5 7 M OK System* 5 672087500-27.Wo 209 80 98 Fig. 5 Sealed system [*] When a System boiler has a diverter valve fitted, the System filter should be on the heating return not the cylinder return 672087500-03.Wo Fig. 7 28mm System filter Dimensions 22mm version 83 0 22.5 Fig. 6 OK Combi Combi - sealed system 5 672087500-28.Wo The following instructions are designed to assist engineers in the safe and effective installation and servicing of the Greenstar System Filter and should be followed at all times. Any queries arising from either the installation or servicing should be directed to Worcester, Bosch Group Technical Support. 279 0 252 The Greenstar system filter should only be installed by a competent person. If in any doubt, consult a qualified heating engineer. 672087500-0.Wo Fig. 8 Dimensions 28mm versions Greenstar System Filter 672087500 (205/07) 5

Installation Installation NOTICE: Before commencing any work, turn off the electrical supply to the heating system. Deburr the cut ends of the pipe and fit the nuts and olives over the pipe ends Drain the central heating Choose a suitable location on the return pipe to the boiler Use the template [] to mark out a section of pipe, cut and remove that section: A = 50mm for the 22mm system filter A = 88mm for the 28mm system filter 672087500-06.Wo A 672087500-05.Wo Fig. 0 Fit the isolating valves and tighten the compression fittings firmly, but do not over tighten Secure the system filter connections by hand Fig. 9 Pipework preparation Fig. Fit the system filter 672087500-08.Wo 6 Greenstar System Filter 672087500 (205/07)

Installation Fit C clips between the valve body and the knurled nuts to ensure the knurled nuts are tight Fig. 2 C clips Loosen the lid assembly using lid tool provided and remove the assembly and sleeve 672087500-09.Wo 672087500-5.Wo Fig. Add inhibitor. Refill the system 2. Using a radiator key, open the vent to allow the air in the system to escape Close the valve when water runs out 2 Fig. 3 Remove the lid Ensure that the valves are in the open position as indicated by the green marker on the valve Add a recommended system inhibitor Replace the lid assembly and sleeve and secure using the lid tool provided, do not overtighten 672087500-2.Wo Fig. 5 Refill the system Final actions: Run the central heating system and check for leaks on the System Filter Clean the System Filter case, ensure any leak detection fluid that may have been used to check for gas leaks on the boiler is removed from the filter and isolation valves Attach the self-adhesive label stating Your boiler and system are protected by a Worcester Greenstar System Filter that is supplied with the System Filter, to the boiler in a prominent position 672087500-7.Wo Greenstar System Filter 672087500 (205/07) 7

Servicing 5 Servicing NOTICE: Before starting any servicing work, isolate the electrical supply to the heating system.. Turn both isolation valves to the OFF position as indicated by the red marker on the valve. Using the lid tool, loosen the lid assembly Worcester, Bosch Group recommends for best practice that where any O ring seals are disturbed that these O ring seals are replaced. 2. Use a radiator key to open the air vent 3. Using the valve tool, open and remove the drain plug; use a suitable container to collect any water and debris. Replace the drain plug and secure with the valve tool, do not overtighten Fig. 7 Release the lid Remove the lid assembly and sleeve 672087500-2.Wo Close drain 2 Do not to over tighten 3 Open drain 672087500-3.Wo Fig. 8 Sludge removal 672087500-.Wo Fig. 6 Drain the filter 8 Greenstar System Filter 672087500 (205/07)

Servicing NOTICE: Sludge disposal Magnetite sludge can stain certain types of sinks or basins Rinse the magnetite sludge into a stainless steel or plastic container Top up the system with a recommended Inhibitor Replace the sleeve and lid assembly and tighten by hand Secure the lid firmly, do not over tighten, using the lid tool. Under running water slide the sleeve off the magnet 2. Rinse the magnetite sludge off the sleeve 3. Rinse the end of the sleeve to remove any non-magnetic debris. Remove the end cap and rinse any non-magnetic debris form inside the trap Replace and secure the end cap Slide the sleeve back over the magnet Remove sleeve 672087500-22.Wo Clean 3 Fig. 20 Top up. Turn both valves to the open position, as indicated by the green marker on the valve 2. Use a radiator key to open the air vent to release any trapped air; when water flows out, close the vent Clean 2 2 Clean Fig. 9 Clean the sheath 672087500-7.Wo Fig. 2 Vent the system Greenstar System Filter 672087500 (205/07) 9

Guarantee 5. Spare parts 22mm System filter Part number Item 8767923 Lid tool 876792 Valve tool 8767925 Air vent assembly 8767926 O ring pack 8767927 Sleeve assembly 22mm 8767928 Valve assembly A 22mm 8767929 Valve assembly B 22mm 8767933 Valve C clip 876793 Drain plug assembly 28mm System filter Part number Item 8767923 Lid tool 876792 Valve tool 8767925 Air vent assembly 8767926 O ring pack 8767952 Sleeve assembly 28mm 8767953 Valve assembly A 28mm 876795 Valve assembly B 28mm 8767933 Valve C clip 876793 Drain plug assembly Water treatment products Suitable water treatment products can be obtained from the following manufacturers: ADEY - Tel: 022 56700 or www.adey.com FERNOX - Tel: 0870 60 5000 or www.fernox.com SENTINEL - Tel: 0800 389 670 or www.sentinel.net 6 Guarantee Guarantee Terms and Conditions This appliance is guaranteed against faulty materials or workmanship for a period of 2 calendar months from the date of installation subject to the following conditions and exceptions; (i) that during the period of this guarantee any components of the unit which are proved to be faulty or defective in manufacture will be exchanged or repaired free of material charges and free of labour charges if repaired directly by Bosch Thermotechnology Ltd, (ii) invoices for attendance and repair of this appliance by third parties will not be accepted for payment by Bosch Thermotechnology Ltd, (iii) that the householder may be asked to prove the date of installation and that the appliance was correctly commissioned, (iv) the guarantee must be registered within 30 days of installation. (v) that any product or part thereof returned for servicing under the guarantee must be accompanied by a claim stating the Model, Serial Number, Date of Installation, (vi) that Bosch Thermotechnology Ltd will not accept responsibility for damage caused by faulty installation, neglect, misuse or accidental damage or the non-observance of the instructions contained in the Installation and Users Instructions leaflets, (vii) that the appliance has been used only for normal domestic purposes for which it was designed, (viii) that this guarantee applies only to equipment purchased and used in mainland Great Britain. 'For full terms and conditions, please visit: worcesterbosch.co.uk/terms-and-conditions. Guarantee registration Your Greenstar appliance carries a guarantee against faulty material or manufacture subject to Terms and Conditions. Guarantee Registration can be completed: Via the Worcester, Bosch Group guarantee app: By scanning the System Filter label bar code, all the filter information is populated in the app, so you just need to fill out the property and installer details On-line: You can register on our website: www.worcester-bosch.co.uk/guarantee By post: Fill out the guarantee card and return it to Worcester, Bosch Group The guarantee app can be downloaded to your smart device from Apple itunes, Google Play or via the Worcester, Bosch Group website 0 Greenstar System Filter 672087500 (205/07)

Service record 7 Service record It is recommended that your system filter is serviced annually at the same time as the main appliance service and that this Service Interval Record is completed as proof of the service. Service Provider Before completing the appropriate Service Record Below, please ensure you have carried out the service as described in the servicing section of the manual. Always use Worcester approved spare parts. Service Service 6 Service 2 Service 7 Service 3 Service 8 Service Service 9 Service 5 Service 0 Greenstar System Filter 672087500 (205/07)

WORCESTER, BOSCH GROUP: TECHNICAL SUPPORT: 0330 23 3366 APPOINTMENTS: 0330 23 9339 SPARES: 0330 23 9779 LITERATURE: 0330 23 99 TRAINING: 0330 23 066 SALES: 0330 23 9669 Worcester, Bosch Group Cotswold Way, Warndon, Worcester WR 9SW. Tel. 0330 23 9559 Worcester, Bosch Group is a brand name of Bosch Thermotechnology Ltd. worcester-bosch.co.uk 672087500 (205/07)