Installation and servicing instructions

Similar documents
DEFENDER DEFENDER. Models: MD22A OPERATION MANUAL. Full Flow Magnetic Filter

IntaKlean Installation & Servicing Instructions IKMF22 and IKMF28

CalMag Filter Installation Instructions

Greenstar System Filter

PRODUCT GUIDE. High performance heating system filter Improves energy efficiency Captures magnetic and nonmagnetic.

CalMag Heating Pack Installation Instructions

Eliminator TotalGuard Installation Manual

Installation guide Billi B-3000 Sparkling Dual levered slimline tap option

Commercial product range

Enzo Safe Touch Thermostatic Shower EZ10010CP & EZ10014CP

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Rise. Digital. Bath with overflow filler. Rise Digital Bath installation instuctions page 1

Aquatique. Shower heads. Fixed and adjustable height heads. Aquatique shower kits installation guide page 1

Contents. Commissioning 6 Operation 6 Routine Preventative Maintenance 6 Fault Finding 7 Spares Parts 8 Technical Support 9

Please tape down. NewTeam Ltd. Customer Service Dept. Brunel Road Earlstrees Industrial Estate Corby Northants NN17 4JW

Where the tap has a removable aerator on the spout exit it can be removed and cleaned periodically to maintain optimum flow performance.

Prism Thermostatic Recessed Shower with Integral 2 Outlet Diverter

Quartz. Digital. Bath with bath waste filler. Quartz Digital Bath with bath waste filler installation instuctions page 1

Enzo Concealed Shower Mixing Valve

M07. Wunda Premium Manifold. Before you start: Check the contents THE BRAND YOU CAN TRUST

For commercial & industrial systems. Large volume dirt collection capacity

B OILER MAG XT. 2 flanged - COD flanged - COD flanged - COD flanged - COD flanged - COD.

Spectrum TM. Installation, Service & Operation Manual O FLO. SoftH 2. Water Softener. Table of Contents

Beautifully Traditional

BLADE BATH SHOWER MIXER DECK MOUNTED CHR WITH KIT INSTALLATION INSTRUCTIONS P BS-E A/2

Aquamixa. Thermo. Thermostatic shower valve with manual bath fill

Quartz. Thermo. Concealed shower valve with adjustable head. Quartz Thermo installation guide page 1

Installation and Servicing Instructions

Boiler protection kit guide

Rycroft Supapac Plate Heat Exchangers

MK 8706 / MB 8706 CONCEALED THERMOSTATIC SHOWER VALVE INSTALLATION GUIDE

568X, 587X, 588X Series

PERFORMANCE SHOWER PRODUCTS

Safety. Rinse Kit for Multi-Pro 1200 and 1250 Turf Sprayers Model No Safety and Instructional Decals. Installation Instructions

Enzo and Enzo Deluxe Safe Touch Thermostatic Shower EN10031CP & EN10035CP

INTA ION MODERN BAR / BATH SHOWER MIXER CP

Beautifully Traditional

HEAVY DUTY BRASS SHOWER PUMPS

METIS. Installation instructions. Riser rail kit INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER.

Beautifully Traditional

Installation, Operation and Maintenance Instructions for ThermaFlex Gasketed Plate Heat Exchangers

OWNER S MANUAL AND INSTALLATION GUIDE PLEASE READ THIS MANUAL CAREFULLY BEFORE ATTEMPTING INSTALLATION

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Installation Instructions. For the 18 Built-In Dishwasher and Front Color Panels

METRO BASIN MONO MIXER CHR

Wave. BATH SHOWER MIXER MONOBLOC With Kit Deck Mounted

Single Lever Pull out Kitchen Tap

Puro Mini Dual Control Shower Mixer PU90010CP

569, 570, 571, 572 Series

569, 570, 571, 572 Series

UB110DNC/L/U/B BASIN MONOBLOC WITH NO POP-UP WASTE BASIN MONOBLOC TALL WITH NO POP-UP WASTE UB112DNC/L/U/B INSTALLATION INSTRUCTIONS

Dynapac Chip Spreader is an accessory that enables the spreading of stone chippings, gravel or other similiar granulates in conjunction with the

Please take time to carefully read through these guidelines before using your Kamco pump.

Zen Boiling Tap Range

Installation, Operation & Maintenance Instructions

HI-LINE LV FAN CONVECTOR MODEL: 7-4.

Please take time to carefully read through these guidelines before using your Kamco pump.

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

SLIM-LINE RC FAN CONVECTOR.

Please take time to carefully read through these guidelines before using your Kamco pump.

SuperKlean Washdown Products

SINGLE LEVER CERAMIC DISC MANUAL SHOWER VALVE

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Zip Econoboil. On wall boiling water. Installation instructions & user manual. Model number: ,

Winchester Heated Towel Rail. Fitting Instructions

Installation Instructions and User Guide. Thermostatic Recessed Dual Control Shower Valve. Models covered: CAS SHCVO C, COB SHCVO C, ORB SHCVO C,

INSTANTANEOUS ELECTRIC SHOWER

Jetflush 4 Instruction Manual

Telo Shower Mixing Valve TL10016CP

Assessment Schedule - TS.6

SEALED THERMAL STORE

ERGOMAX 7 INSTALLATION

COMPRESSED AIR DRYER. SAFETY... Page 2 MAINTENANCE... Page 5. INSTALLATION... Page 3 PARTS AND KITS... Page 6

Alkaline RO System INSTALLATION MANUAL

Installation guide Sahara & Sahara Plus

Mira Sport Max with Airboost

WC2 & WC3 Installation & Maintenance Instructions

Basin Mixer. Installation & Aftercare Instructions. Please retain for future reference.

SYSTEM MANUAL Description

Mio Concealed Shower Mixing Valve MI40010CP

These instructions must be left with the user.

BASIN MIXERS INSTALLATION & AFTERCARE INSTRUCTIONS

METRO BATH FILLER MOUNTED CHR

MEGAFLO HE Iss 1

USER MANUAL PLEASE READ THROUGH ALL INSTRUCTIONS BEFORE USE ANY FURTHER QUESTIONS PLEASE CALL OUR TECHNICAL HELP LINE:

INSTALLATION & TECHNICAL MANUAL

LO-LINE RC & LO-LINE RC HEATER/COOLER FAN CONVECTOR MODELS: 6-4, 9-6, 14-10,

SLIM-LINE RC. Installation, Operating, Maintenance and After Sales Manual. Please leave this manual with the end user. Part Number: Issue 3

SHOT BLAST CABINET USER INSTRUCTIONS. Model No: CSB20B. Part No: GC05/13

Installation, Operation and Maintenance Instructions ThermaFlex Gasketed Plate Heat Exchanger OM010

Twin & Triple Exposed Thermostatic Shower Valve Installation & Operating Guide

Artisan Thermostatic Bath Filler

VISAGE INSTALLATION GUIDE

OUTDOOR DISHWASHER INSTALLATION INSTRUCTIONS

SYSTEMS for CATALYTIC FILTERS

Pop-up Clicker Drain Installation and User Guide

Go Greener, with Gas.

These instructions must be left with the user.

Installation, Operating and Servicing Instructions

Smile Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Transcription:

Installation and servicing instructions

Installation MagnaClean Professional is suitable for all central heating systems and can be fitted anywhere on the main circuit. However, in order to achieve the best protection for the boiler, it is recommended that MagnaClean Professional is fitted after the last radiator before the boiler. In determining a suitable location for installation, it is important to ensure you allow adequate access for servicing. The following instructions are designed to assist engineers in the safe and effective installation and servicing of ADEY s MagnaClean Professional and should be followed at all times. Any queries arising from either installation or servicing should be directed to your supervisor or ADEY direct on 01242 546700. 1 Drain the central heating system or plug-off feed and expansion tank and release the system pressure. Measure and mark a 110mm section for a 22mm unit and a 195mm section for a 28mm unit when making the connections with elbows supplied, as shown in 3 below. When installing below a boiler or other object, allow 250mm clearance from the top of the canister to beneath the object, to enable the lid assembly to be removed when servicing. This applies to both 22mm and 28mm MagnaClean Professional canisters. 2 Open vented system Using a suitable cutter, carefully remove the marked section of pipework to create the correct opening. 3 Combi/Sealed system In both diagrams, position A is best practice while B is suitable. N.B. We firmly recommend MagnaClean Professional is installed and serviced by a qualified heating engineer. Prepare the pipe and fittings accordingly. Lubricate the olives and assemble the valves on the pipe. Hand tighten.

Servicing 4 1 Loosely secure the MagnaClean Professional canister to the valves. Grip the MagnaClean canister and tighten the compression fittings being careful not to over tighten. 5 Important Before commencing any servicing work, turn off electrical supply to the boiler. Ensure the water is not too hot to undertake work on the system. Turn off both isolation valves to the marked OFF position. Loosen the air vent to release internal pressure. When venting, protect the surface below the canister with a dust sheet or container to capture any drops of water. 2 Loosen off the valve flange nuts and insert the rubber washers provided. Thoroughly tighten the flange nuts. Do not over tighten. Refill the heating system. 6 Protecting the nation s central heating systems Using the MagnaClean Professional lid spanner, carefully unscrew the lid. 3 Installer: Telephone: Installation date: Serial No. Run the central heating system while checking for leaks. Attach the self-adhesive MagnaClean Professional label to the boiler, indicating your name, telephone number, date of installation and serial number. Always service the filter before leaving the premises. The lid and valve spanner can be left with the customer. Remove the complete lid assembly from the MagnaClean Professional. Turn the lid assembly upside down in order that the underside of the lid acts as a drip tray.

Chemical dosing 4 1 Wrap paper towelling around the build-up of sludge on the plastic sheath. Place lid assembly over a bucket and remove the plastic sheath from the magnet, remove the sludge then rinse clean. Replace the sheath over the magnet. With a standard radiator key remove the Pro-Fill air vent. The built-in, one-way valve will prevent water from escaping. Attach chemical adapter and feed in chemical. 5 2 6 Replace the lid assembly onto the canister and tighten until sealed. Do not over tighten. Wait for five seconds before removing the adaptor. The Pro-Fill air vent will accept all market-leading chemicals in either liquid or concentrate form. 3 Open the isolation valves to the marked ON position and vent/bleed through the Pro-Fill air vent. Protect the surface below the canister with a dust sheet or container to capture any drops of water. Run the central heating system while checking for leaks. Repeat steps 1-6 if required. Ensure the filter is thoroughly clean before leaving the premises. Replace the Pro-Fill air vent. Allow the system to circulate for 30 seconds. Open the Pro-Fill screw two turns and back flush until clear.

Your questions answered Q. Where can I fit MagnaClean Professional? A. MagnaClean Professional is suitable for all central heating systems and can be fitted anywhere on the main heating circuit. In order to achieve the best protection for the boiler, it is recommended that MagnaClean Professional is fitted between the last radiator and the boiler (see diagram overleaf). In determining a suitable location for installation, it is important to ensure you allow adequate access for servicing. Q. Which connection on the MagnaClean Professional canister is the flow and which is the return? A. The inlet and outlet on MagnaClean Professional are reversible and there is no flow restriction. Q. Can I fit MagnaClean Professional horizontally? A. MagnaClean Professional can be fitted in any orientation. Each isolation valve can rotate through 360 making it possible to install in a vertical position on horizontal pipework. Q. How often do I service MagnaClean Professional? A. MagnaClean Professional has been designed to retain, on average, a year s build-up of sludge. Therefore, servicing is required once a year with the annual boiler service. If the system has a heavy sludge build-up, or a power-flush was not carried out, we recommend cleaning the filter at appropriate intervals during the first year of installation and annually thereafter. It is easy to check the filter periodically, following the instructions overleaf. Q. Can I use chemicals with MagnaClean Professional? A. Yes. You can use any chemical or acid agents on the market with MagnaClean Professional. The patented Pro-Fill air vent has been designed to allow installers to insert chemicals directly into the system as described overleaf. Chemical dosing kits for this purpose are available to purchase through your local plumbing merchant. Alternatively, remove the lid and use the canister as a dosing vessel. Q. What is the lifespan of MagnaClean Professional? A. MagnaClean Professional has been designed to last for the lifetime of the boiler, normally ten years. It provides continuous protection and comes with a two year warranty. Registering your warranty is straightforward and can be done online at www.adeysolutions.co.uk Q. How do I isolate the valves? A. Simply turn the valves to the marked OFF position using the spanner provided. The valves rotate 360 in either direction. Important: Remember to switch off the electrical supply to the boiler when servicing MagnaClean Professional. Q. What can I install on 28mm pipework? A. We recommend installing MagnaClean Professional 28mm which has been designed for this purpose. MagnaClean Professional 28mm can also be installed onto 22mm pipework where greater sludge capacity is required. Q. I have a pacemaker, will MagnaClean Professional affect me? A. As with all magnetic products, if you have a pacemaker caution should be taken when handling MagnaClean Professional at all times. When MagnaClean Professional is installed, the magnetic field outside the canister is approximately one tenth of an average fridge magnet. Q. What other size MagnaClean products do you provide? A. When a MagnaClean product is required for larger pipework, up to 35mm, two MagnaClean Professional 28mm units can be fitted in parallel with no flow restriction. For pipework larger than 35mm we would recommend using MagnaClean Industrial from our commercial range. For more information call our sales team direct on 01242 546700 or visit our website, www.adeysolutions.co.uk

Developed by independent heating specialists ADEY Professional Heating Solutions, MagnaClean Professional has been specifically designed for the efficient maintenance of central heating systems. We live in an age of high efficiency boilers, but for many years, little attention has been given to the cleanliness of central heating systems. The majority of systems suffer from black iron oxide contamination. This creates thick sludge deposits which are the result of corrosion taking place within radiators and other metallic components. The oxide particles range from very large to sub-micron in size with the latter leaching into the system water continuously during use. These particles bond to all components often causing premature failure of pumps and valves. When they contaminate the boiler heat exchanger and pipe work, it results in a dramatic loss of efficiency. It is widely recognised that even a minimal build-up results in a serious drop in boiler efficiency. MagnaClean Professional has been carefully designed to remove these particles from suspension while at the same time allowing a 100% flow rate through the system. Installation is simple with each isolation valve rotating through 360 and therefore supporting any number of location options. These valves have been specifically designed for use with MagnaClean Professional and have high quality PTFE and EPDM seals. An added advantage for installers is the Pro-Fill air vent built in to the lid. This special vent incorporates a unique, one-way valve, allowing the installer to inject corrosion inhibitor chemicals directly into the MagnaClean Professional canister without the need to isolate any part of the system. Just remove the air vent screw, inject the chemical and replace the air vent screw. It s that simple. MagnaClean Professional provides years of protection maintaining the high efficiency of central heating systems. It also results in financial benefit and increased reliability. The product is backed by a two year limited guarantee. IMPORTANT Always follow the Standard Electrical Best Practice guidelines when installing MagnaClean Professional. A copy of these guidelines can be found at www.hse.gov.uk/electricity. The inlet and outlet on MagnaClean Professional are reversible and there is no flow restriction. Following installation, don t forget to complete the warranty card. Alternatively, complete the registration online at www.adeysolutions.co.uk Faulty components must be returned under the warranty process Contact ADEY Customer Care Department on 01242 546700 for further information. Telephone: 01242 546700 Email: info@adeysolutions.co.uk www.adeysolutions.co.uk Produced from recycled material