LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

Similar documents
Spectron LSN (Life Safety Network) Suggested Specifications

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

Central Emergency Lighting Inverter Systems

elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Light Support Power Systems CENTRAL EMERGENCY LIGHTING INVERTER SYSTEMS

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

NYC Approved Product Series

CALTECH Pasadena, CA

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

Guide Specification Model CTG Automatic Transfer Switch

Product Specifications 3 Breaker Main Disconnect Panel with Undervoltage Trip

Product Specifications 4 Breaker Main Disconnect Panel with Undervoltage Trip

HIGH BAY APPLICATIONS

Control Panel. 1.0 GENERAL SCOPE OF WORK Introduction... 2

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

LORAIN CSP DC Power System

DGC-1000 DIGITAL GENSET CONTROLLER

Control Relay Modules

LORAIN CIP 4890/48120 DC Power System

AND ARCHITECT SPECIFICATIONS

Refrigerators. Upright Blood Bank. i.series Horizon Series

elite TM SERIES Centralized Emergency Lighting Inverters MODEL ELE

SECTION POWER SUPPLIES AND DISTRIBUTION

Installation Guide for models:

EON TM. 10 kw - 55 kw THREE PHASE. Centralized Emergency Lighting Inverters MODEL EL3

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. NXM Series - Survive-All. Emergency Light Unit

Series. Access Power Controllers. Installation Guide

Liebert PPC Second Generation Power Distribution Cabinet

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Power Supplies. Overview

Multi-Output Access Control Power Supply Charger VDC or 24VDC VDC or 3 24VDC.

INTELLIGENT FIRE ALARM CONTROL PANEL

Multi-Output Access Control Power Supply Chargers VDC or 24VDC VDC or 4 24VDC.

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

Freezers. Upright Laboratory & Plasma. i.series Horizon Series

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Addressable Fire Alarm Control Panel

Product Specifications 480 VAC, 175A Main Power Distribution Panel

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

Installation Guide for models:

AS950 REFRIGERATED SAMPLERS

DIVISION FINNED WATER-TUBE BOILERS

Product Specifications 480 VAC, 70A Main Power Distribution Panel

DIESEL Engine Fire Pump Controllers Features

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

Industrial Freezer Sales A division of IDS 5311 Derry Avenue Building D Agoura Hills CA Phone (818) Fax (818)

PowerWave 2 Busway System

Excel-EN Conventional Fire Control Panel

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

IOTA Exit Signs. IOTA Emergency Fixtures

DIVISION COMMERCIAL, GRID-TYPE, FINNED-TUBE, GAS DOMESTIC WATER HEATERS

Commercial and Light Industrial Fire Alarm Control Panel

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

PS1240x Series Dual Voltage Access Control Power Supply Systems Operating and Installation Instructions Rev D.01

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

DIVISION FINNED WATER-TUBE BOILERS

APC Refrigeration Distribution Unit (RDU) Guide Specifications

Product Specifications Auto Restart Main Power Distribution Panel

Fire control panels FC726 FC726-XA

Freezers. Laboratory & Plasma. i.series Horizon Series

EVO192 v3.0 Fire and Burglary What s New

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

» EN50171» Lighting» Reliable

Catalog Number. Notes. Type. FST Snap on frosted, diffuse L/LENS No diffuser

DIVISION FINNED WATER-TUBE BOILERS

XTHERM, TYPE WH - MODELS 1005A- 2005A DIVISION COMMERCIAL, WATER-TUBE, CONDENSING GAS DOMESTIC WATER HEATERS

Operating & Maintenance Manual. Alert-4 Ethernet LCD Master Alarm

SECTION LOW VOLTAGE LIGHTING CONTROLS

IntelliKnight 5820XL Addressable Fire Alarm Control System Sales Guide

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

Intelligent Security & Fire Ltd

Control/Communicator Installation Manual

SECTION AUTOMATIC TRANSFER SWITCHES

SECTION AUTOMATIC TRANSFER SWITCHES

WITH POWER TRANSFER SWITCH STANDARD SUBMITTAL PACKAGE

AS950 PORTABLE SAMPLERS

ECC-50/100C. Emergency Command Center

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. HZM-Series-Class I, Div 2 Battery Unit. Instalation instructions

SPECIFICATION CHEMGARD INFRARED GAS MONITOR SERIES

DIESEL Engine Fire Pump Controllers Features

"ESDDR" Series Electric Humidifier

1.1 REFERENCES.1 American National Standards Institute/National Fire Protection Association (ANSI/NFPA).1 ANSI/NFPA 20, Centrifugal Fire Pumps.

DGC-500 DIGITAL GENSET CONTROLLER

PACKAGED AIR COOLED Product Data Catalog

THX-DL Data Logger USER & INSTALLATION MANUAL V

CONVENTIONAL FIRE ALARM CONTROL UNITS. MR-2300 SERIES Fire Alarm Control Units MEA

CPS V Cabinet Power System

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Cutting Edge Compressor Technology

TT /97. Features INSTALLATION INSTRUCTIONS. Horn. Lamps

Transcription:

LiteMinder Fast Transfer System 1.0 to 18.75KVA LED Compatible Series Pure Sine Wave Modular Technology Modular AC System Evenlite s LiteMinder Central System provides an innovative Emergency Lighting solution for today s complex energy saving systems, light sources and maintenance requirements. The LiteMinder represents the pinnacle of engineering excellence with features not found in the traditional systems currently available: Modularity: LiteMinder features unique inverter modules available in increments from 1.0 to 18.75 KVA capacities(see ordering guide). Modules are interconnected to build the required system capacity, and can even be field upgraded to increase system sizes! Modules can be configured to provide Single Phase, Split Phase, and Three Phase outputs thereby eliminating costly, inefficient external transformers. Control Features: A keypad and LCD display provides user interface and extensive status diagnostics. Self-test, Self-Diagnostics in compliance with UL 924 is field configurable, and stores 1,000 Test, Event and Alarm logs thereby eliminating the need for costly manual test and data recording. Web Site Monitoring: unique web interface constantly monitors the system status and records all essential data. Users can log on, view, interact and download records as needed. The factory can also monitor, diagnose remotely. Diagnostics: In addition to Self-test, Self- Diagnostics, LiteMinder also includes unique startup diagnostics to aid in installation and maintenance: Eight individual startup alarms (Communications, Set-Up Conflict, Low Battery, Back-feed, Transfer/AC Fuse, Short/Overload, Miswire, Incorrect AC ) eight individual Charger Alarms and eight individual Alarms. ARRA Compliant for Levels 1&2 Project name: Approved By: 2575 Metropolitan Drive, Trevose, PA 19053 USA TEL: (800) 872 0879 FAX:(215) 244 4208 Catalog No: Type No:

PWM MOSFET and IGBT ( Model Dependant) provide Pure Sine Wave output with less than 3% THD, and fully compatible with LED Lighting Loads Fast transfer for H.I.D. compatibility ensures smooth operation of combined lighting loads, transfers in less than 2 ms Modular inverter allows operation for single phase or three phase operation to order Less than 3% THD, load power factor 0.5 Lag to 0.5 Lead, 98% efficient in standby mode Automatic Low Voltage Disconnect (LVD) set at 1.67 VPC Automatic restart upon utility power return, no need to manually reset the system circuit breaker is provided sized to system rating Shorted circuit protected to 65KAIC tested and approved to UL 6180-5-1 standard UL924 compliant Self-Test/Self-Diagnostics are standard, with interactive LCD display Monthly and the annual 90 minute test can be programmed by the user for a specific date and time to ensure NFPA Code Compliance Up to 1000 events stored in the memory log on a FIFO basis, and is easily accessible thru the MMI MMI (Man-Machine Interface) consists of a 5 button keypad for easy menu navigation A 4x20 backlit White display with heads-up LED s allow for a quick diagnosis of the system status and alarms Five LED indicators provide the status of the, Charger, AC present, Ready, and Switched Load (if provided with Switched Output Circuit s) An additional six LED indicators provide the alarm status for Alarm Summary, Bypass (if equipped with Maintenance Bypass option), CB Trip, Startup Fault, Charger Fault, and Fault A dedicated System Test button is provided for a user initiated 30 second on demand test An Alarm On/Off LED is provided to indicate that an audible alarm is present. A dedicated Alarm Silence On/Off push button allows the user to silence the audible alarm SD card slot allows the user to download all Test, Event and Alarm Logs The Meter Menu allows the user to access the and Output Voltages, Output Current, Output VA, Battery Voltage, Battery Current, Battery Power, Temperature, System Days, minutes and Events Crest factor >4 for high inrush demanding loads, overload 120 percent for 10 minutes, 400 percent for 500mS The inverter and battery cabinets are constructed from 14 gauge CRS and are powder painted with no visible outside bolts or hardware Internally the inverter has all galvanized or painted steel parts for all modules and shelves to resist corrosion and provide high durability Installer friendly front mounted battery terminals for easier and faster installation VRLA Maintenance Free Lead Calcium Battery s provide the required 90 minute minimum run time Battery recharge time is less than 24 hours, meets all UL 924 and NFPA101 Life Safety Code requirements Operating temperature 20 to 30 C Three Rate Charger circuit is fully temperature compensated for added reliability Brownout protection set for 85% of the nominal line voltage Electronics are warranted for 2 years and the VRLA batteries have a 10 year warranty, optional factory startup increases the warranty to 3 years Listed to UL924, and meets NFPA101 Life Safety Code, NFPA70-NEC and OSHA Requirements,1.0-2.8KVA models meet CSA C22.2 No. 141-10 Warranty: (For full warranty details see warranty data sheet CPS-WAR) Electronics: Evenlite Inc. warrants the series electronics assembly (except batteries) against defects in material and workmanship for a period of two years or three years with Factory Startup option. Battery: Evenlite Inc. warrants the LC series Lead Calcium batteries carry a 1 year full, 9 year pro-rated limited warranty.

ORDERING GUIDE Single Phase Model VA Rating Phase Configuration Voltage Output Voltage Output Configuration Options 1000 VA 1600 VA 2200 VA 2800 VA 3200 VA 4200 VA 5200 VA 6250 VA 8250 VA 10500 VA* 12500 VA* *277VAC ONLY 1P Single Phase 120 or 277(L-N) IA IB 120V (L-N) 277V (L-N) OA 120V (L-N) OB 277V (L-N) *C(n) 20A Normally On Output *O(n) 20A Normally Off Output *S(n) 20A Switched Output (n) = Quanity Required BB Indicates Special Current Requirement, Contact Factory Quantity Limitations (Any combination of output types) 1000VA 8 x 20A Normally On without TA option 4 x 20A Normally Off With or Without TA Option 4 x 20A Switched With or Without TA Option 5 x 20A Normally On with TA Option 1600-3000VA 11 x 20A Normally On without TA option 6 x 20A Normally off With or Without TA Option 6 x 20A Switched With or Without TA Option 7 x 20A Normally On with TA Option 4200-6250VA 12 x 20A Normally On without TA option 6 x 20A Normally Off With or Without TA Option 6 x 20A Switched With or Without TA Option 8 x 20A Normally On with TA Option 8250-12500VA 24 x 20A Normally On without TA option 12 x 20A Normally Off With or Without TA Option 12 x 20A Switched With or Without TA Option 16 x 20A Normally On with TA Option *TA Trip Alarm for all circuit breakers TB 1 Summary / 2 programmable terminal block for form C dry contacts MB Internal Maintenance Bypass Switch (make before break) DT Delayed Transfer, 60 ms Z4 Seismic Zone 4 certified RA Remote Annunciator M(n) Maintenance Plan, n= years (5 max.) EW Extended Warranty to 5 Years (EW requires FS) FS Startup commissioning on Site WM Wall Mount Kit (1KW only) *Maximum Number of Trip Alarms Model Dependant Example: -12500-1P-IB-OB-S4-TA-FS Model No of s Width Height Depth Weight *Weight Battery **Total Shipping Weight Max. BTU s/ Hr. at Full Load 1000 1 24 38 13 308 lbs. N/A 343 lbs. 68 1600 1 32 52 13.75 414 lbs. N/A 449 lbs. 109 2200 1 32 52 13.75 492 lbs. N/A 527 lbs. 150 2800 1 32 52 13.75 570 lbs. N/A 605 lbs. 190 3000 1 32 52 13.75 648 lbs. N/A 683 lbs. 209 4200 1 32 50 23 995 lbs. N/A 1,030 lbs. 286 5200 1 32 50 23 1,155 lbs. N/A 1,190 lbs. 355 6250 1 32 50 23 1,280 lbs. N/A 1,350 lbs. 426 8250 2 32 50 23 400 lbs. 1,570 lbs. 2,040 lbs. 563 10500 2 32 50 23 400 lbs 1,890 lbs. 2,340 lbs. 716 12500 2 32 50 23 400 lbs. 2,210 lbs. 2,660 lbs 852 * Battery/ cabinet weight is with batteries installed ** Total shipping weight includes pallets and packaging *10500 and 12500 are only offered in 277VAC input/output

ORDERING GUIDE Split & Two Phase Model VA Rating Phase Configuration Voltage Output Voltage Output Configuration Options 2200 VA 4200 VA 5200 VA 6250 VA 8250 VA 10500 VA 12500 VA 1S 2P Split Phase Two Phase ID IC IE 120V/120V/240V L-N / L-N / L-L 3 Wire + Ground 120V/120V/208V 277V/277V/480V L-N / L-N / L-L 3 Wire + Ground OD 120V/120V/240V L-N / L-N / L-L 3 Wire + Ground OC 120V/120V/208V OE 277V/277V/480V L-N / L-N / L-L 3 Wire + Ground *C(n) 20A Normally On Output *O(n) 20A Normally Off Output *S(n) 20A Switched Output (n) = Quanity Required BB Indicates Special Current Requirement, Contact Factory Quantity Limitations (Any combination of output types) 2200VA 6 x 20A Normally On without TA option 4 x 20A Normally Off With or Without TA Option 4 x 20A Switched With or Without TA Option 4 x 20A Normally On with TA Option 4200-12500VA 24 x 20A Normally On without TA option 12 x 20A Normally Off With or Without TA Option 12 x 20A Switched With or Without TA Option 16 x 20A Normally On with TA Option Note: split and two phase inverters require breakers per phase so must be specified in multiples of two *TA TB MB DT Z4 RA M(n) EW FS Trip Alarm for all circuit breakers 1 Summary / 2 programmable terminal block for form C dry contacts Internal Maintenance Bypass Switch (make before break) Delayed Transfer, 60 ms Seismic Zone 4 Certified Remote Annunciator Maintenance Plan, n= years (5 max.) Extended Warranty to 5 Years (EW requires FS) Startup commissioning on Site *Maximum Number of Trip Alarms Model Dependant Example: -12500-2P-ID-OD-S4-TA-Z4-FS Model No of s Width Height Depth Weight *Weight Battery **Total Shipping Weight Max. BTU s/ Hr. at Full Load 2200 2 24 38 13 200 lbs 420 lbs. 635 lbs. 150 4200 2 32 50 23 350 lbs. 680 lbs. 1,030 lbs. 286 5200 2 32 50 23 350 lbs. 840 lbs. 1,190 lbs. 355 6250 2 32 50 23 350 lbs. 1,000 lbs. 1,350 lbs. 426 8250 2 32 50 23 375 lbs. 1,570 lbs. 2,020 lbs. 563 10500 2 32 50 23 375 lbs 1,890 lbs. 2,340 lbs. 716 12500 2 32 50 23 375 lbs. 2,210 lbs. 2,660 lbs 852 * Battery cabinet weight is with batteries installed ** Total shipping weight includes pallets and packaging

ORDERING GUIDE Three Phase Model VA Rating Phase Configuration Voltage Output Voltage Output Configuration Options 3000 VA 5200 VA 8250 VA 10500 VA 12500 VA 15750 VA 18750 VA 3P Three Phase 120/208 or 277/480 IF 120V/208 L-N//L-L IG 277V/480V L-N/L-L 4 wire + Ground OF 120V/208 L-N//L-L OG 277V/480V L-N/L-L 4 wire + Ground *C(n) 20A Normally On Output *O(n) 20A Normally Off Output *S(n) 20A Switched Output *(n) = Quantity Required BB Indicates Special Current Requirement, Contact Factory Quantity Limitations (Any combination of output types) 3000VA 6 x 20A Normally On without TA option 3 x 20A Switched With or Without TA Option 3 x 20A Normally Off With or Without TA Option 3 x 20A Normally On with TA Option 5200-18750VA 24 x 20A Normally On without TA option 12 x 20A Switched With or Without TA Option 12 x 20A Normally Off With or Without TA Option 15 x 20A Normally on with TA Option *TA TB MB DT Z4 RA M(n) EW FS Trip Alarm for all circuit breakers 1 Summary / 2 programmable terminal block for form C dry contacts Internal Maintenance Bypass Switch (make before break) Delayed Transfer, 60 ms Seismic Zone 4 Certified Remote Annunciator Maintenance Plan, n= years (5 max.) Extended Warranty to 5 Years (EW requires FS) Startup commissioning on Site *Maximum Number of Trip Alarms Model Dependant Note: Three phase inverters require breakers per phase so must be specified in multiples of three Example: -15750-3P-IG-OG-S6-TA-MB-FS Model No of s Width Height Depth Weight *Weight Battery **Total Shipping Weight Max. BTU s/hr. at Full Load 3000 2 24 38 13 218 lbs. 576 lbs. 820 lbs. 205 5200 2 32 50 23 565 lbs. 1,060 lbs. 1,890 lbs. 355 8250 2 32 50 23 565 lbs. 1,532 lbs. 2,210 lbs. 563 10500 2 32 50 23 565 lbs. 1,850 lbs. 2,530 lbs. 716 12500 2 32 50 23 565 lbs 2,161 lbs. 2,850 lbs. 853 15750 3 32 50 23 565 lbs. 2,908 lbs. 3,630 lbs. 1,074 18750 3 32 50 23 565 lbs. 3,380 lbs. 4,120 lbs. 1,279 * Battery cabinet weight is with batteries installed ** Total shipping weight includes pallets and packaging

Overall Mechanical Dimensions 1KVA Single 24 17.25 2.50 4x 2.50 16x dual knockout 1-1/8 and 7/8 dia. 2x 1.75 Top 24 AC Panel 3 feet minimum clearance in front of all units 13 6x 2.0 38 30.3 21.6 Man Machine Interface Panel Right Side 4x 1.75 24.5 38 Master 4.0 2.5 6.5 Bracket, Floor Mounting Inter-cabinet Battery Cable Ports for Vertical Mounting Mounting Slot See Detail.75 x 2.13 Slot for Floor Mounting 9.97 Knockout pattern identical to left side 1.38.31 Dia. holes for 1/4 hardware Floor Mounting Brackets and to Vertical Mounting Mounting Slot Detail 21.00 Floor Mounting Bolt Pattern 1.5 1.5

Overall Mechanical Dimensions1.6-3.0 KVA Single 6x.88 and 1.13 knockouts for AC connection 2.50 32.00 27.00 2x 2.50 2x 1.75 2x 1.75 13.75 9.75 2.00 36.00 min. clearance in front of all units 12 Circuit Panel location 16.00 7.86 MMI Interface Panel 4x.88 and 1.13 knockouts each side of cabinet 45.00 55.00 45.87 35.53 6.50 4.00 1.50 29.00 4x.76 x 2.26 slot 2x 10,46 1.71 Floor Mounting Bolt Pattern

Overall Mechanical Dimensions 4.2 to 18.75KVA 23.0 36 Min. Clearance in front of all units 12 Circuit Panel location 32.0 MMI Interface Panel 50.0 36.3 37.6 4.0 4200-6250 single phase uses a single cabinet for inverter and batteries 26.84 2.57 Battery Connection Knockout locations 23.0 36 Min. Clearance in front of all units 24 Circuit Panel location 32.0 MMI Interface Panel 32.0 2x 6.64 4.86 Floor Mounting Bolt Battery Pattern No. 1 2x 13.28 O.40 6x per cabinet mounting holes 32.0 Battery No. 2 50.0 37.6 28.3 4.0 8250-12500 single phase requires two cabinets (inverter 5.16 and batteries) 3x 26.84 5200-12500 three phase requires two cabinets (inverter and batteries) Configuration Single Phase 16-24 Batteries - 1 cabinet, 1 Battery cabinet 15750-18750 three phase requires three cabinets (inverter and batteries) Three Phase 8-24 Batteries - 1 cabinet, 1 Battery cabinet Three Phase 30-36 Batteries - 1 cabinet, 2 Battery cabinets 2.57 2x 6.64 2x 13.28 Floor Mounting Bolt Pattern O.40 6x per cabinet mounting holes 4.86

EVENLITE Single Phase s /Output Current Chart Power Voltage Current Minimum Required Suggested Feed Power Voltage Current Minimum Required Suggested Feed 1000 120 10.4 13.0 20 5200 120 52.1 65.1 70 208 6.0 7.5 20 208 30.0 37.6 40 240 5.2 6.5 20 240 26.0 32.6 40 277 4.5 5.6 20 277 22.6 28.2 30 480 2.6 3.3 20 480 13.0 16.3 20 1600 120 16.7 20.8 30 6250 120 62.5 78.1 80 208 9.6 12.0 20 208 36.1 45.1 50 240 8.3 10.4 20 240 31.3 39.1 40 277 7.2 9.0 20 277 27.1 33.8 40 480 4.2 5.2 20 480 15.6 19.5 20 2200 120 22.9 28.6 30 8250 120 83.3 104.2 110 208 13.2 16.5 20 208 48.1 60.1 70 240 11.5 14.3 20 240 41.7 52.1 60 277 9.9 12.4 20 277 36.1 45.1 50 480 5.7 7.2 20 480 20.8 26.0 30 2800 120 29.2 36.5 40 10500 N/A N/A N/A N/A 208 16.8 21.0 30 208 60.1 75.1 80 240 14.6 18.2 20 240 52.1 65.1 70 277 12.6 15.8 20 277 45.1 56.4 60 480 7.3 9.1 20 480 26.0 32.6 40 3000 120 31.3 39.1 40 12500 N/A N/A N/A N/A 208 18.0 22.5 30 208 75.1 93.9 100 240 15.6 19.5 20 240 65.1 81.4 90 277 13.5 16.9 20 277 56.4 70.5 80 480 7.8 9.8 20 480 32.6 40.7 50 4200 120 41.7 52.1 60 Notes: 208 24.0 30.0 30 1. Current = Output Current + Max Charge Current 240 20.8 26.0 30 2. Suggested Feed sizes are rounded up 277 18.1 22.6 30 in 10 Amp increments 480 10.4 13.0 20 na - Not Available KAIC Rating for all models = 65KAIC (UL rated per UL 61800-5-1)

EVENLITE Three Phase s /Output Current Chart Power Voltage Current Minimum Required Suggested Feed Power Voltage Current Minimum Required Suggested Feed 3000 120/208 10.4 13.0 20 10500 120/208 34.7 43.4 50 277/480 4.5 5.6 20 277/480 15.0 18.8 20 4000 120/208 13.9 17.4 20 12500 120/208 43.4 54.3 60 277/480 6.0 7.5 20 277/480 18.8 23.5 30 5200 120/208 17.4 21.7 30 15750 120/208 52.1 65.1 70 277/480 7.5 9.4 20 277/480 22.6 28.2 30 8250 120/208 27.8 34.7 40 18750 120/208 62.5 78.1 80 277/480 12.0 15.0 20 277/480 27.1 33.8 40 Notes: 1. Current = Output Current + Max Charge Current 2. Suggested Feed sizes are rounded up in 10 Amp increments 3. Power requires 3 Wires, Neutral and Ground. Neutral is passed through and current carrying - Feeder Neutral to be sized same as Line conductors. KAIC Rating for all models = 65KAIC (UL rated per UL 61800-5-1)