MIRADOR Real Time Monitoring

Similar documents
Cold chain monitoring technologies. Facility monitoring

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

The Centron Presidio Monitoring System. Centron. Presidio. Rees Scientific. An ISO 9001:2008 Company

Common Customer Challenges

D3 Wireless temperature alarm & monitoring system family. tek-troniks

DATAssure. Laboratory wireless alarm & monitoring system

Exceptional data integrity. Complete peace of mind.

IceSpy System5. A big deal in the world of large scale environmental monitoring INDUSTRY SPECIFIC PRODUCT SOLUTIONS HEALTHCARE.

IceSpy System5. A big deal in the world of large scale environmental monitoring FOOD INDUSTRY SPECIFIC PRODUCT SOLUTIONS COMPLIANCE REGULATORY

SPY RF solution, to make your quality assurance simple

THERMOMETERS Dataloggers/Refrigerator

Affordable wireless monitoring without compromise

NEW. RF500 Wireless Monitoring. and improved. Exceptional data integrity. Complete peace of mind.

Temperature Monitoring, Operation and Maintenance of Research Freezers and Refrigerators SOP-TMOMRFR-01

The data logger is supplied with a lithium metal battery which typically gives two years logging life.

Affordable wireless monitoring without compromise

REAL TIME LABORATORY MONITORING SYSTEM

The 6 Most Important Parts of a Temperature Monitoring System

Thermo Scientific Smart-Vue Wireless Monitoring Solution obsessive is SMART

For over 30 years, our focus has been to protect animal health and research in Pharmaceutical, Government and University animal research facilities.

PQS performance specification

Smart Wireless Sensor

Data Logging Solutions

DC Voltage Sensor. Specifications Didactum DC sensor: The sensor is automatically detected by the Didactum base unit. Accuracy: 1%

WHO PQS-Code E006/020. Fridge-tag 2 Storage temperature monitor with USB port

AirTest Technologies Inc.

CAN unit for Analog Sensors

REMOTE MONITORING AND ALARM SYSTEM

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Refrigerator/Freezer Thermometer

EcoView Energy Management System

Itron Water Loss Management Solutions. Advanced Digital Leak Detection Overview Session

Ultra low temperature freezers for long-term storage at -86 C UF V 500, UF V 700

Outdoor Temperature Sensor

Building Automation Systems from Grantek: Going Beyond Compliance to Improve Operations

Q-tag CLm doc family Type: doc / doc L / doc LR / doc D

Refrigerator/Freezer Thermometer

Differences Matter: Knowing BMS and EMS Systems By: Jason Kelly

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

ISO New Product Catalog. Addendum 2014 TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS

Contamination Control for Life Science Applications

Typical applications include the vibration detector. Detection of vibrations and shocks

data logger DL200H DL200D DL200L

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Realtime monitoring the IVF laboratory: Practical aspects. Ronny Janssens Quality manager

Smart Wireless Sensor

DataSheet. Thermocouple Logger

Waspmote Plug & Sense! Quick Overview

Tinytag Plus LAN Data Logger with Temperature & Relative Humidity Probe (-25 to +85 C/0 to 100% RH) Standalone. Tinytag Connect

FX150 OTDR. Platform Highlights. Key Features

DataSheet. Thermocouple Logger

Fig.: A fire in a server room or data center may cause devastating damage. Protect your infrastructure.

Accessories, interfaces, sensors and complete solutions.

EZT-570S Touch Screen Controller The Next Generation Controller with Smartphone Technology

Temperature Monitoring System. Specifications

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Simple, digital wireless reporting.

ULTRA.GUARD ultra low temperature freezer

PyroButton Catalog. Minimal configuration of PyroButton self-powered data-logger system:

BATTERY-POWERED TEMPERATURE SENSOR

PRIMEXTEMP SERIES SENSOR

HydroFlex 3-in-1 microplate strip washing. Flexible and reliable microplate strip washing and vacuum filtration in a compact, modular platform

ThermoControl 0 C - 10 C - 20 C - 30 C

HydroFlex FLEXIBLE AND RELIABLE MICROPLATE STRIP WASHING AND VACUUM FILTRATION IN A COMPACT, MODULAR PLATFORM. 21 CFR Part 11* 98/79/EC IVD-D*

NYS Vaccines for Children (VFC) Program Fridge-Tag 2L Data Logger: Implementation and User Guide

The New DUSTTRAK II and DRX Aerosol Monitors

EVOSAFE-SERIES TM ULTRA-LOW TEMPERATURE FREEZERS

Laboratory Refrigerator/Deep Freezer TC 802

Specifications Minimum Typical Maximum Unit

USER MANUAL. ITAG 4 / ITAG 4 Bio/ ITAG 4 TH DATA LOGGER. UM-ITAG REV.B 03/02/2016

MicroRay IR-100 NEW. Inspection MicroRay IR-100

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

wireless. web-based. worthy of the name RACO.

Messenger Wireless Lock Access Network

New. ENERGY STAR Certified VIP ECO Earns Industry s Lowest Energy Consumption Rating for Ultra-Low Temperature Freezers 1

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Walk in Freezer. Comfortable work environment

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

TEMPERATURE MEASUREMENT & CALIBRATION SPECIALISTS. Temperature Monitoring & Control. product catalog 2012

Are you still stuck with the current status of manual thermometer recording? X Labor Intensive X No History X Inaccurate

The New DUSTTRAK II and DRX Aerosol Monitors

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C

Temperature Data Logging

Testo Digital Vacuum Gauge with Bluetooth

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Skyresponse ThingWorx Extension. Version 1.0. User Guide

Dräger X-zone 5500 Area Monitoring

EL-USB-2-LCD+ High Accuracy Humidity, Temperature and Dew Point Data Logger with LCD

FLOOD SERIES DATA SHEET

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

YOUR TRUSTED PARTNER IN RETAIL SECURITY

Pharmagraph. envigil-fms Environmental Monitoring System

Hugs Product Guide Specification

Dual Probe Vaccine Temperature Data Logger w/ Software-Less Reporting

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

Testo Digital Vacuum Gauge with Bluetooth. Instruction manual

2014, TempSen Electronics Company

Complete Security Solution

EL-OEM-3 OEM Packaged Voltage Data Logger

Transcription:

MIRADOR Real Time Monitoring Mirador is a web-based application for 24/7, real-time monitoring. This platform is available as a custom configuration to fit multiple applications of environmental monitoring during the various stages of production, storage and transportation. This fully secure system complies with regulatory requirements of the life science, pharmaceutical, healthcare and food industries. It enables you to gain visibility and control over your critical cold chain operations. Mirador can monitor conditions found in a variety of environments, such as warehouses, cold rooms, fridges, ovens, freezers, trucks, incubators, server rooms and lab rooms, to name a few. Even if the measure or desired precision is not found in the list below, it is possible to have your project evaluated by our experts in order to adapt Mirador to your particular needs. AVAILABLE MEASURES (-196 C to 300 C / -320.8 F to 572 F) Relative humidity (0-100%) Carbon dioxide (0 à 10%) Differential pressure Atmospheric pressure Door opening detection Power failure detection Water detection Absolute pressure Starting and stopping of critical devices

APPLICATIONS Warehouses Sensors are installed in the warm and cold areas of you warehouse to register environmental conditions. The sensors transmit data to a reader every 5 minutes, which then relays the information to the Mirador software interface. In case of power failure, or a loss of communication between the sensor and the reader, data are still registered and stored within the reader s internal memory, preventing any loss of data. Once communication between the two devices is reestablished, the data are transmitted to the server. Trucks Mirador can measure the environmental conditions in your trucks. The sensors are installed in the trailers and register conditions throughout the transportation process. The sensors then transmit the data to the reader as soon as communication is established (can connect within a distance of 1km in open field). Once connected, the reader relays the data to the server and appears on the software interface. Refrigerators, freezers, cryogenic freezers, or ovens: our sensors can measure temperatures ranging between -196⁰C and 300⁰C (-320.8⁰F and 572⁰F). This allows you to monitor the environmental conditions of cold chain facilities and equipment without having to do it manually. Refrigerators & Ovens Whether for use in a laboratory, or in the agri-food industry, Mirador allows you to measure the temperature, relative humidity, or carbon dioxide levels within your incubators in real time. Incubators Product Placing the sensor probe in a bottle of glycol makes it possible to measure the temperature of the products themselves, not the ambient temperature of the refrigerator. This prevents an alarm from being triggered due to a door opening, unless the physical products are truly affected.

MIRADOR SYSTEM OVERVIEW Mirador wireless sensors are configured with user-specific alarm thresholds and measurement intervals. The sensors are then strategically placed in applicable areas to monitor environmental conditions. The sensors record data and transmit the data to a reader. This reader is connected to the dedicated server where Mirador has been centrally installed or remotely hosted. The web portal provides immediate access to real-time and historical sensor data for all monitoring locations. Compliant graphs and reports may be easily retrieved from the portal. Reports are available in multiple formats, such as text report, graph and interactive graph, pdf, or.csv export to Excel. If and when a temperature excursion occurs, alerts can be delivered via text, email or pager. Mirador monitors your facilities and equipment to help you maintain the integrity of your products at all times.

INFORMATION: THE WHERE AND WHEN The Mirador Web Portal makes accessing data easy. The main interface is a representation of your installation with sensor locations and real-time readings received from sensors. It displays the list of recent alarms triggered by the system, as well as alarm status messages (acknowledge information and comments). It is also used to access other screens depending on user privileges. Various floor plans are available and can be linked to specific users. Daily reports of alarms triggered, calibration expiry dates and recorded temperatures are available. All recorded data can be stored on your own servers. Information can be retrieved in multiple formats, including text report, graph and interactive graph, pdf, or.csv export to Excel. Alarm capabilities are key features of the Mirador system. The system can alert you of sensorlevel readings (i.e. temperature excursions), or system-level issues including power failure, network connectivity loss, damage to a sensor, etc. Alarm notifications can be delivered via text message, email or pager, so a designated person can investigate the reason for the alarm and take immediate action. An audit trail interface is used to display all interventions and actions recorded by the system, in compliance with the FDA code 21 CFR Part 11. Alarm relays can also be installed to connect the system to an alarm company, such as Chubb or ADT to help reduce the risks of product loss. Please note that Cryopak is not affiliated with any alarm company and these names are only given as an example. In addition: Mirador software validation is available upon request and is required by various regulations that are currently in place. This validation process covers the installation, operation and performance of the software. The protocol will be written and approved by Cryopak Verification Technologies (CVT) and the customer. The execution can either be done by CVT, or the customer. Once the execution is completed, a final report will be written.

Mirador is a fully secure and compliant system that automates the process of monitoring your facilities and equipment for enhanced visibility and control of your cold chain operations. All projects are analyzed by our team of experts to give you a real-time monitoring system that perfectly fits your needs, while ensuring that you adhere to the standards of your industry. FEATURES & BENEFITS 24/7 monitoring of temperature, relative humidity, differential pressure and/or carbon dioxide Secure and global access to data via the internet or intranet (via Mirador web portal) Alarm notifications via text, email or pager Eliminates manual temperature monitoring and keeps records safe Recalibration program available No Downtime Recalibration Exchange Program Automatic software updates 9 Point Complies with FDA code 21 CFR part 11 Versatile 4 alarm thresholds Easy to use and implement no need for expensive hard-wired devices Flexible system that can be adapted to your particular requirements

MIRADOR SYSTEM COMPONENTS MIRADOR Sensor Specifications (by logger type) xtagdisplay Reader xtag2 xtag2 & Range Accuracy Resolution -40 C / +85 C (-40 F/+185 F) -40 C / +85 C (-40 F/+185 F) -40 C / +85 C (-40 F/+185 F) ±0.5 C ±0.5 C ±0.5 C ±0.0625 C ±0.0625 C ±0.0625 C Range - - 0-100% Accuracy Resolution - - 3% - - ±0.01% CO2 Level - - - PSIG - - - Data Storage 4 Gb + USD card holder 2 Mb 2 Mb Battery Life Up to 4 hours Up to 14 months (rechargeable) Up to 14 months (rechargeable) Battery Type 1.85A/H Li-ion Polymer 1.85A/H Li-ion Polymer 1.85A/H Li-ion Polymer Interfaces USB, external power supply, passive POE (power over Internet) USB, external power supply USB, external power supply Radio Selectable 16 channels @2,4GHz Selectable 16 channels @2,4GHz Selectable 16 channels @2,4GHz Typical Dimensions 5 x 3 x 1.25" 127 x 76.2 x 31.8 mm 3.5 x 2.25 x 1 88.5 x 57.2 x 25.4 mm 3.5 x 2.25 x 1 88.5 x 57.2 x 25.4 mm Certifications & Industry Standards certificate on 9 points, FCC & IC approved certificate on 9 points, FCC & IC approved certificate on 9 points, FCC & IC approved Applications Warehouse, cold room, truck, fridge & freezer (external sensor) Warehouse, cold room, truck, fridge & freezer (external sensor) Warehouse, cold room, truck, fridge & freezer (external sensor)

MIRADOR SYSTEM COMPONENTS MIRADOR Sensor Specifications (by logger type) xtag2 Cryogenic xtag2 High xtag2 Carbon Dioxide xtag2 Differential Pressure Range Accuracy Resolution -196 C / 0 C (-320.8 F / 32 F) 100 C / 300 C (212 F / 572 F) - - ±2.0 C ±2.0 C - - ±0.7 C ±0.7 C - - Range - - - - Accuracy Resolution - - - - - - - - CO2 Level - - 0-10% - PSIG - - - 0-100 PSIG Data Storage 2 Mb 2 Mb 2 Mb 2 Mb Battery Life Up to 14 months (rechargeable) Up to 14 months (rechargeable) Up to 14 months (rechargeable) Up to 14 months (rechargeable) Battery Type 1.85A/H Li-ion Polymer 1.85A/H Li-ion Polymer 1.85A/H Li-ion Polymer 1.85A/H Li-ion Polymer Interfaces USB, external power supply USB, external power supply USB, external power supply USB, external power supply Radio Typical Dimensions Selectable 16 channels @2,4GHz Selectable 16 channels @2,4GHz Selectable 16 channels @2,4GHz Selectable 16 channels @2,4GHz (external sensor only) (external sensor only) (external sensor only) (external sensor only) Certifications & Industry Standards certificate on 9 points certificate on 9 points certificate on 3 points certificate on 3 points Applications Cryogenic freezer Industrial Oven Incubator White room, autoclave, sterilizer

ABOUT CRYOPAK Cryopak is a cold chain solutions provider for the pharmaceutical, life sciences, biotech and food industries. The company manufactures items for temperature-sensitive shipping needs, including insulated shipping containers, gel packs, phase change materials and temperature monitoring devices, and also offers package design and testing services in its ISTA certified labs. Cryopak delivers superior products and service from an industry-leading team of experts whose primary goal is to ensure and protect product integrity. Cryopak is headquartered in Edison, New Jersey, with locations across the United States, Canada, Panama and France. For more information QC / Maritimes / Ontario 1.888.423.7251 sales@cryopak.com www.cryopak.ca Western Canada 1.800.667.2532 sales@cryopak.com www.cryopak.ca