SP900X Piezoresistive Monosilicon Pressure Transmitter

Similar documents
DMP305X-TST single crystal silicon gauge pressure transmitter

DMP305X-TST-H monosilicon gauge pressure transmitter

DMP305X-TST-S monosilicon gauge pressure transmitter

MODEL APT 3700N. Smart Pressure Transmitter For Nuclear Service. Duon System Co., Ltd. for Differential / Gauge / Absolute Pressure Measurement

Rosemount 4500 Hygienic Pressure Transmitter

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Oil & Gas. Features:

MEAS Subermsible Liquid Level Pressure Transducer SPECIFICATIONS. Features. Applications

M5200 Industrial Pressure Transducer

RPS/DPS High Accuracy Resonant Pressure Sensor. GE Measurement & Control. Features:

Rosemount 4500 Hygienic Pressure Transmitter Demonstrated best-in-class performance during SIP/CIP for process temperatures up to 400 F (204 C)

M7100 Pressure Transducer

U86B. Urea Dosing SPECIFICATIONS FEATURES APPLICATIONS

Series EDA Electronic Pressure Controller. Specifications - Installation and Operating Instructions

Model 144H. Product Data Sheet , Rev DB February Content

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

U5700 Submersible Liquid Level Pressure Transducer

U5300 Industrial Pressure Transducer

M5800 Pressure Transducer with Rotatable Display

Intrinsically Safe Pressure Transmitters for installation in hazardous locations Models IS-20-S, IS-21-S, IS-20-F, IS-21-F WIKA Datasheet IS-20

Pressure sensors. Ex ia I / IIC T6 acc. to ATEX. Features. Description. Measuring ranges. Applications

SHIMADEN DIGITAL INDICATORS

Rosemount 3051L Level Transmitter

Rosemount 2090P Pulp and Paper Pressure Transmitter

Rosemount 3051CFP Integral Orifice Flowmeter

Heavy Duty Pressure Transducers Line Guide

Rosemount 2051T In-Line Pressure Transmitter

D5100 Industrial Differential Pressure Transducer

Series EDA Electronic Pressure Controller

DP86 Constant Voltage with Fitting

Rosemount 2051T In-line Pressure Transmitter

Analog Room Pressure Monitor RPC Series

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4400

Rosemount 3051CFC Compact Flowmeter

Installation and operation manual DPC200 - DIFFERENTIAL PRESSURE CONTROLLER. Low pressure with PI-control-mode

Beck. The differential pressure transmitter for air

Absolute and Gage Pressure Transmitter

D5100 Industrial Differential Pressure Transducer

Section B Field Instruments

Laboratory Honeywell Technology Solutions, Bangalore-EMC Lab, 19/2, Devarabisanahalli Village, K.R. Puram, Varthur Hobli, Bangalore, Karnataka

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

ST 3000 Smart Transmitter Series 900 Extension Models. Specification and Model Selection Guide. Introduction 34-ST /04

SmartLine Pressure Transmitter ST 700 Basic Quick Start Installation Guide 34-ST-25-57, Revision 1, December 2016

MSP100 Pressure Transducer

SP-2400 & 2410 Series Smart Valve Positioner (Linear & Rotary)

M5800 Pressure Transducer with Rotatable Display

Model 144H. Product Data Sheet , Rev DB February Content

S304 and S305 Dust Emission Monitors. User Manual. Distributor

Rosemount 3051S MultiVariable Transmitter

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Differential pressure gauge with electrical contact type Model: P650 series

OPTIBAR DP 7060 Supplementary Instructions

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25H, STT25S, STT25M, STT25D EN0I-6031 March 2010 Rev.

Gas cylinder scale Model GCS-1

INTRINSICALLY SAFE Pressure Transducer / Transmitter AST4401

Audible warning devices for external alarm

Heavy Duty Pressure Transducers

Dräger Polytron 5100 EC Detection of toxic gases and vapors

316L SS Pressure Sensor High Pressure 0-100mV Output Absolute

Sanitary Pressure Transmitter

FT702LT Turbine control wind sensor gives durability a new meaning FT702LT. series

User s Manual YTA610 and YTA710 NEPSI Certification

STS Directory Accreditation number: STS 0009

LOW PRESSURE Intrinsically Safe Transducer AST44LP

85 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Rosemount 644 Temperature Transmitter

Dräger Polytron 5700 IR Detection of flammable gases and vapours

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

86 Compensated SPECIFICATIONS. 316L SS Pressure Sensor Small Profile 0-100mV Output Absolute and Gage Temperature Compensated

Metal Tube Variable- Area Flow Meter (Series KM, KMS, KMSS)

Fisher LCP100 Local Control Panel

Rosemount 2090F Hygienic Pressure Transmitter

Magnetic-Inductive Flow Velocity Sensor PIT. Device Description

ENERGY, OIL & GAS. astsensors.com macrosensors.com. Transducer & Transmitter Capabilities. Your sensor business partner...

Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

MSP300 Pressure Transducer

Series A3 and A4 Differential Pressure Controller

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Instruction Manual DIGITAL MANIFOLD FOR HVAC/R SYSTEMS

PRESSURE TRANSMITTERS

82 Constant Voltage SPECIFICATIONS. 316L SS Pressure Sensor 19mm Diameter Package 0-100mV Output Absolute and Gage Temperature Compensated

SmartLine Pressure Transmitters Modular, Accurate and Robust for the Lowest Cost of Ownership

Rosemount 3051P In-Line Pressure Transmitter. Product Data Sheet August , Rev BA

Data sheet. Pressure transmitter type MBS 33M (Marine) dustriels Automatik. Indus. Industrial IK.20.U2.C2

Rosemount 3051 Pressure Transmitter

Azbil introduction 2015

Dräger Polytron 8700 IR Detection of flammable gases and vapors

U5600. Wireless Pressure Transducer SPECIFICATIONS

Differential Pressure and Flow Meter Media 5 Indicator 160 PN 40

Rosemount 2088 Absolute and Gage Pressure Transmitter

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Differential Pressure and Flow Meter. Media 5 Indicator 160 Ø PN 50

Dräger Polytron 8310 IR Detection of flammable gases and vapour

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Rotameter series 250 metal tube variable area flowmeter

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

POSITIONERS CONTROLS ELECTRO-PNEUMATIC INTELLIGENCE FOR DOUBLE & SINGLE ACTING PNEUMATIC ACTUATORS SERIES 6A. The High Performance Company CELEBRATING

89BSD Digital Output

NORTH AMERICAN ADVANCED TECHNOLOGIES, INC.

Lamp Supply (Recommended)

Transcription:

Product introduction SP900X is a high-performance digital pressure transmitter using MEMS (Micro-Electro-Mechanical System) monosilicon technology worldwide to meet rigorous and demanding industrial applications with optimum accuracy, linearity and repeatability. The monosilicon sensor element is mounted within a capsule and measures the transfer of pressure through the insulated diaphragm and filling fluid. The complete insulation of the encapsulation prevents the sensor from being affected by changes in ambient temperature, electrical interference and mechanical vibration. All this technology enables the SP900X to easily handle extreme chemical and mechanical situations with strong resistance to electromagnetic interference (EMI) sufficient to respond to the most demanding environments and industrial applications. SP900X-H Through the display and electronic module (via 3 buttons) or via HART communication protocol, the transmitter can be configured in the field or remotely for a new measuring range, definition of a new unit of measurement, type of alarms and type of analog output. The LCD display shows the adjustment parameters and the process variable. The display can be rotated allowing installation in any position. The robust housing has a viewing window for the LCD display and external push buttons which makes it easy to set parameters safely when applied in a classified area. Both the housing and the electronic module have certifications to work in classified areas: - Flameproof (Exd IIC T6) - Intrinsically safe (Exia IIC T4) SP900X-S Main parameters Field of application Pressure types Measuring range Output signal Reference accuracy Gauge pressure 1kPa-40MPa, please refer to the ordering information chapter 4-20mA,4-20mA+HART,customer ±0.075% URL,optional ±0.05%URL Pressure, level Approvals Measuring medium Liquid, gas, or steam flow as well as liquid level, density and pressure. 1.

Technical specifications Measuring range and limit Nominal value Smallest calibratable span Lower range limit(lrl) Upper range limit(url) Overload limit 6kPa 1kPa -6kPa 6kPa 25MPa 40kPa 2kPa -40kPa 40kPa 25MPa 250kPa 12.5kPa -100kPa 250kPa 25MPa 1MPa 50kPa -100kPa 1MPa 25MPa 3MPa 150kPa -0.1MPa 3MPa 25MPa *10MPa 500kPa -0.1MPa 10MPa 25MPa 40MPa 5MPa -0.1MPa 40MPa 42MPa The unit of the measuring range above can be converted into kg/cm², MPa and kpa, etc. Provide other measuring range according to requirements. Adjust requirements: lower range value (LRV) and upper range value (URV) can be adjusted within the scope of the upper and lower range limit, smallest calibratable span URV - LRV URL *Nominal value of DMP900X- MST -H 10MPa Standard specifications and reference conditions Mounting position effects Test standard: GB/T28474 / IEC60770; Zero basedcalibration span, Silicon oil filling, 316L stainless steel isolation diaphragm, 4-20mA analog output. Apply to any position. Max value lower than 400Pa can be corrected by zero clearing function. Performance specifications The overall performance including but not limited to reference accuracy, environment temperature effects and other comprehensive error Typical accuracy: ±0.075%URL Stability: ±0.2% URL/ year Reference accuracy Vibration effects According to GB/T 1827.3/IEC61298-3 tests, <0.1% URL Output signal 4-20mA two wire. Customers can choose linear output or square root output. Digital process variables superimpose on 4-20mA signal and apply to any hosts with HART protocol. Standard and reference conditions, including linearity (BFSL), hysteresis and repeatability. calibration temperature: 20 ± 5 Linear output accuracy TD 10(Note1) ±0.075%URL Nominal value: 6kPa 40kPa 10<TD<20 ±0.0075% URL Note 1: TD is Turn down, TD=URL/ URV-LRV 250kPa 1MPa 3MPa 10MPa 40MPa Ambient temperature effects(typical) Total impact Within the range of - 20-80 Insulation resistance ±(0.1+0.1TD)% URL Power supply effects 20M Ω@, 100VDC Zero and span change should not be more than ± 0.005% URL/V when power supply changes in 10.5/16.5-55VDC. 2.

Technical specifications Damping time Power supply Total damping time constant: equal to the sum of damping time of amplifer and sensor capsule Damping time of amplifer : 0-100S adjustable Diaphragm capsule (isolation sensor diaphragm and silicon oil filling) damping time: 0.2s Startup after power off : 6S Normal services after data recovery: 31S Weight Net weight: about 1.87kg ( without mounting bracket and process connection adaptor ) Item Standard/flame proof HART protocol Operating conditions 10.5-55VDC 16.5-55VDC,Communication load resistance 250Ω Load resistance 0-2119 Ω for working condition, 250-600Ω for HART protocol Transmission distance Power consumption <1000m 500mW@24VDC,20.8mA Power supply and load requirements Environment condition Items Working temperature Storage temperature Media temperature Working humidity Protection class Operational condition -40-85, integrated LCD display: -20-70 -40-110, integrated LCD display: - 40-85 Silicon oil filling: -40-120 5-100% RH@40 IP67 R (Ω ) External load resistance 2119 600 250 0 R= U-10.5 0.021 Digital communication range HART 10.5 16.5 23.8 55 Power supply voltage U(V) EMC environment NO. Test items Basic standards Test conditions Performance level 1 Radiated interference GB/T 9254/CISPR22 30MHz-1000MHz OK 2 Conducted interference (DC power port) GB/T 9254/CISPR22 0.15MHz-30MHz OK 3 Electrostatic discharge immunity test (ESD) GB/T 17626.2/IEC61000-4-2 4kV(Contact ),8kV(Air) B(Note2) 4 Immunity to radio frequency EM-fields GB/T 17626.3/IEC61000-4-3 10V/m(80MHz-1GHz) A(Note1) 5 Power frequency magnetic field Immunity test 6 Electrical fast transient / Burst Immunity Test GB/T 17626.8/IEC61000-4-8 30A/m A(Note1) GB/T 17626.4/IEC61000-4-4 2kV(5/50ns,100kHz) B(Note2) 7 Surge immunity requirements GB/T 17626.5/IEC61000-4-5 1kV(Line to line) 2kV(Line to ground) (1.2us/50us) 8 Immunity to conducted disturbances induced by radio frequency fields B(Note2) GB/T 17626.6/IEC61000-4-6 3V(150kHz-80MHz) A(Note1) (Note 1)Performance level A: The preformance within the limits of normal technical specifications. (Note 2)Performance level B: Temporary reduction or loss of functionality or preformance, it can restore itself. The actual operating conditions, storage and data will not be changed.. 3.

Menu function Specific menu Measuring menu set Transmission module type Output signal Local control Remote control 4-20mA+HART LCD/3 buttons on body HART 4-20mA LCD/3 buttons on body - Mark State URV Upper range value LRV Lower range value Damping time LCD display unit Units S 0-100 Setting range Display mode PV ma Details Process variable shows on main screen, percentage and progress bar shows on secondary screen Current shows on main screen, percentage and progress bar shows on secondary screen % Percentage shows on main screen, percentage and progress bar shows on secondary screen Unit Unit kpa MPa bar psi mmhg mmh2o mh2o inh2o fth2o inhg mhg TORR mbar g/cm2 kg/cm2 Pa ATM mm m Definition Kilopascal Megapascals Bar Pounds per square inch Millimetre(s) of mercury@0 Millimeter of water@4 Meter of water@4 Inches of water@4 Feet of water@4 Inches of mercury@0 Meter mercury column@0 Torr Millibar Gram per square centimeter Kilogram per square centimeter PA Standard atmospheric pressure Millimeter(Note1) Meter(Note1) Note1: length unit need mark medium density Analog output type Parameters ma LINER ma Alarm signal Parameters ALARM NO ALARM H ALARM L Fix output Parameters FIX/C NO Output type Linearity Square root Alarm signal None 20.8mA 3.8mA Fix output value None 3.8000 3.8000mA 4.0000 4.0000mA 8.0000 8.0000mA 12.000 12.000mA 16.000 16.000mA 20.000 20.000mA 20.800 20.800mA Quick menu Parameter PV=0 Zero adjustment Span adjustment Restore factory setting Instruction Set current output to zero value, used to correct the error cased by static pressure and installation. 4mA re-range with pressure 20mA re-range with pressure Restore backup data when error. 4.

Product selection instruction Sensor select instruction Electrical connection Code Nominal value H602G 6kPa H403G 40kPa H254G 250kPa H105G 1MPa H305G 3MPa H106G 10kPa H406G 40MPa Deacription Range -6kPa...6kPa, smallest calibratable span 1kPa Range -40kPa...40kPa, smallest calibratable span 2kPa Range -100kPa...250kPa, smallest calibratable span 12.5kPa Range -0.1MPa...1MPa, smallest calibratable span 50kPa Range -0.1MPa...3MPa, smallest calibratable span 150kPa Range -0.1MPa...10MPa, smallest calibratable span 500kPa Range -0.1...40MPa, smallest calibratable span 5MPa Adjust requirements: lower range value (LRV) and upper range value (URV) can be adjusted within the scope of the upper and lower range limit, smallest calibratable span URV - LRV URL Code Item T1 R1 R2 R3 Housing(T1) Electrical connection Cable entry protector Description Aluminum-alloy termimal,2 cable entry M20*1.5(F), red body, white cover Waterproof connector M20*1.5 one side, blind plug another side, PVC material,6-8mm diameter cable only, IP67 Flame proof, 1/2 NPT(F) one side, blind plug another side, stainless steel material, 6-8mm diameter cable only, IP67 Flame proof, (F) one side, blind plug another side, stainless steel material, 6-8mm diameter cable only, IP67 Code Position Description S H S F Diaphragm material Isolation fluid filling SS316L Hastelloy C Sillicon Oil, process temperature: - 45-205 Fluorocarbon oil, process temperature: -10-180 F Sensor seal Stainless steel welding seal Standard cable entry protective adaptor(r1) Diaphragm(S/H) Flame proof cable entry protective adaptor(r2/r3). 5.

Product selection instruction Transmission module Code Items Description F H Output signal Display module(c) 4-20mA two wire, power supply: 10.5-55VDC 4-20mA+HART two wire,power supply: 16.5-55VDC A Display Without display C With LCD display G08 R01 R02 R03 R04 G1/4(M), Φ3 pressure lead hole, GB/T7307, ISO228, DIN16288, BS2779, seal reference DIN3852- E(back-end seal) 1/2-14NPT(M), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 1/4-18NPT(M), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 1/2-14NPT(F), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 1/4-18NPT(F), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 Brackets Terminals Code Items B4 Fixed mounting Instruction U-shaped bracket, 2" pipe, apply to T- structure Fixed mounting bracket (B4)(SP900X-H) Process connection select instruction Code Items Description 4 Material Stainless steel, SUS304 6 Stainless steel, SUS316 M01 Specifications M20*1.5(M), Φ3 pressure lead hole, GB/T193-2003, ISO261 G01 G02 G1/2(M), Φ3 pressure lead hole, EN837 G1/4(M), Φ3 pressure lead hole, EN837 B4 Fixed mouting bracket(sp900x-s). 6.

Product drawing and dimension Drawing and dimension of SP900X-H with display(c) ( unit: mm) 110 20 132 175 48 Drawing and dimension of SP900X-S with display(c) (unit: mm) 133 87 130 2016.05.V1.0. 7.

Product drawing and dimension Drawing and dimension of SP900X-H without display(a) ( unit: mm) 133 20 132 175 48 Drawing and dimension of SP900X-S without display(a) ( unit: mm) 110 87 130. 8.

Product drawing and dimension Fixed mounting braket installation dimension of SP900X-H (B4) ( unit: mm) 176 119 119 R32.50 160 R21 111 26 146 Fixed mounting braket installation dimension of SP900X-S (B4) ( unit: mm) 176 119 过程连接尺寸图 ( 单位 :mm) 119 R32.50 160 R21 26 141 111. 9.

尺寸图 Product drawing and dimension Process connection(m01) (unit: mm) Process connection(g01) (unit: mm) 3 Process connection(g02) (unit: mm) Process connection(g08) (unit: mm) 2 13 2 5 18.9 9.5 G1/4 DIN3852-E G1/4 EN837 14 12 Process connection(r01) (unit: mm) Process connection(r02) (unit: mm) 19 16 2 20 20 17.5 5 GB-T193-2003 3 2 17.5 5 G1/2 EN837 1/2NPT ANSI/ASME 1.20.1 1/4NPT ANSI/ASME 1.20.1. 10.

3 SP900X Piezoresistive Monosilicon Pressure Transmitter Product drawing and dimension 过程连接 Process connection(r03) (R03)( 单位 :mm) (unit: mm) 过程连接 Process connection(r04) (R04)( 单位 :mm) (unit: mm) 21 Heat exchange connector(n1) (unit: mm) Heat exchange connector(n2)(unit: mm) 22 31 21 10 208 121 65 10 19 14 Welding adaptor(z1) (unit: mm) Welding adaptor(z2) (unit: mm) 30 30 G1/2 40 20 40 20 16 14 15 12 1/2NPT ANSI/ASME B1.20.1 1/4NPT ASNI/ASME B1.20.1 6 6. 11.

Ordering information chapter Item Parameters Code Instruction Model SP900X Piezoresistive Monosilicon Pressure Transmitter Sensor Separator - Detailed specifications as following Electrical connetion Pressure range code Diaphragm material H602G H403G Nominal value(url): 6kPa Nominal value(url): 40kPa H254G Nominal value(url): 250kPa * H105G Nominal value(url): 1MPa * H305G Nominal value(url): 3MPa * H106G Nominal value(url): 10MPa * S406S S H Nominal value(url): 40MPa SS316L Hastelloy C Isolation S Sillicon oil, process temperature: -45-205 C fluid filling F Fluorocarbon oil, process temperature: -10-180 C Sensor seal F Stainless steel welding seal Separator - Detailed specifications as following Electrical connetion Cable entry protector T1 R1 R2 R3 Aluminum-alloy termimal, 2 cable entry M20*1.5(F), red body, white cover Waterproof connector M20*1.5 one side, blind plug another side, PVC material, 6-8mm diameter cable only, IP67 Flame proof, 1/2 NPT(F) one side, blind plug another side, stainless steel material, 6-8mm diameter cable only, IP67 Flame proof, M20*1.5(F) one side, blind plug another side, stainless steel material, 6-8mm diameter cable only, IP67 Output Separator - Detailed specifications as following Output signal F 4-20mA two wire, power supply: 10.5-55VDC H 4-20mA+HART two wire, power supply: 16.5-55VDC * Display C LCD display * (*) * * A Without LCD display Process connection Separator - Detailed specifications as following Material 6 SUS316 * Specification M01 M20*1.5 (M), Φ3 pressure lead hole, GB/T193-2003, ISO261 G01 G02 R08 G1/2 (M), Φ3 pressure lead hole, GB/T7307, ISO228, DIN16288, BS2779 G1/4(M), Φ3 pressure lead hole, EN837 G1/4(M), Φ3 pressure lead hole, GB/T7307, ISO228, DIN16288, BS2779, seal refers to DIN3852-E (back-end seal) * *. 12.

Ordering information chapter R01 R02 R03 R04 1/2-14NPT(M), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 1/4-18NPT(M), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 1/2-14NPT(F), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 1/4-18NPT(F), Φ3 pressure lead hole, GB/T12716, ANSI/ASME B1.20.1 * Additional options Separator - Detailed specifications as following Fixed mounting accessory Process connection mounting accessory Process connection accessory /B4 U-shaped bracket, 2" pipe, apply to T-structure * /N1 Heat exchange connector, M20*1.5 (F) change to M20*1.5(M), SUS304 /N2 Heat exchange connector, M20*1.5 (F) change to M20*1.5(M), SUS304 /Z1 Welding connector, M20*1.5(F), SUS304 * /Z2 Welding adaptor, G1/2(F), SUS304 * * * Display mode Calibration report Approvals (multiple) /D1 According to your requirements /Q1 Calibration report provided by our company /E1 Flame proof certificate, ExdIICT6, NEPSI * /I1 Intrinsic safety certificate, ExiaIICT4, NEPSI * /L3 CE certificate *. 13.

Factory settings and parameters Item Menu mark Factory setting value Tag position None 0(No specific settings) Analog output type ma Liner Display mode DISP PV Alarm signal ALARM No Item Menu mark Factory setting value Damping value DAMP 0(No specific settings) 4mA Lower range value 20mA Upper range value LRV URV According to the order According to the order Process unit U According to the order Approvals CE Licence scope Standard Registered number PRESSURE TRANSMITTER EN61000-6-2:2005 EN61000-6-4:2007 AC/0100708 SP_03_2017 Sitron-Brasil R.Baronesa de ltu, 83 Sao Paulo-SP-01231-001 T:(5511)3825-2111 F:(5511)3825-2171 Sitron-USA 1800 Prime Place Hauppauge,NY 11788 PH:516-935-8001 FX:800-516-1656 BRASIL: vendas@sitron.com USA/Other Countries: info@sitron.com. 14.