Laboratory- and sterilisation equipment HMC EUROPE

Similar documents
LABOKLAV. Autoclaves Made in Germany

MADE IN ITALY SERVICE INNOVATION QUALITY RELIABILITY

MEDIACLAVE. Fast, reproducible and safe media sterilization

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Steam sterilizer AHS-75-DRY

TECHNICAL SPECIFICATIONS FOR PLUSHER WDC 8 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 18 SERIES INSTRUMENT WASHER DISINFECTORS

TECHNICAL SPECIFICATIONS FOR PLUSHER WDS 12 SERIES INSTRUMENT WASHER DISINFECTORS

HMC. Sterilization Equipment STERILIZING SIMPLY AND WELL. EUROPE Sterilization Technology

STERILAB Steam sterilizer with gravitation de-aeration (without vacuum pump) for laboratory purposes.

Manual v1 Page 1 of 19. Manual. Laboratory autoclave

HMC. Sterilization Equipment STERILIZING SIMPLY AND WELL. EUROPE Sterilization Technology

CENTRAL STERILISATION. Innovative, hardworking Sterilisation & Infection Control products perfect for your Central Sterile Supply Department

VARIOKLAV Steam Sterilizer 75 S S Operating manual

DEKO Washer-disinfector WASHROOM SYSTEMS

laboratory & sterilization technology

STERIDENT, STERIMAT, STERIMAT PLUS

Matachana Low Temperature Steam and Formaldehyde 130 LF Sterilizer

LOGIC CONTROLLED DEKO 25 EASE OF USE

The power of innovation. For better media preparation. Media preparators Systec MediaPrep.

requirements can be equipped with an additional product temperature control probe, and with a printer.

Your Health, our Technology AWD655. Instrument Washer Disinfector

Manual Page 1 of 8. Manual. Laboratory autoclave

Drying and heating chambers

SHAKING WATER BATHS ENGLISH

Constant climate chamber with ICH-compliant illumination

Tabletop 2340 EA-D Class S Autoclave 19 Litres

Environmental simulation chamber for complex alternating climate profiles

CLINOCLAV steam sterilizer AH-21 L

SST2200 & Stainless Steel Steam Sterilizers SST1700 &

Standard-Incubators. Avantgarde.Line BD BF series. Classic.Line B BD BF series. Solid.Line BD-S series

cgmp STEAM STERILIZERS

Magnetic Stirrer BIOSYSTEM DIRECT BIOSYSTEM Operating Manual Issue

Climate chambers with illumination and humidity The BINDER KBWF series shines with its

Version 7 1/ LXP

DEKO 25 washer-disinfector

FN 032/055/120 DRY HEAT STERILIZERS / OVENS FN 300/400/500 DRY HEAT STERILIZERS / OVENS KD 200/400/700 OVENS EV 018 VACUUM OVEN

Digital incubating/ refrigerating benchtop shakers

Washer disinfectors. > Small - Medium range. devoted to hygiene. For the Environmentally conscious

Plant growth chambers

INSTRUCTIONS CertoClav EL

Constant climate chambers

VS LD series vertical steam sterilizers

SECTION LABORATORY GLASSWARE WASHER Model 1800 LXA PART 1 GENERAL 1.01 SYSTEM DESCRIPTION 1.02 SUBMITTALS 1.03 QUALITY ASSURANCE 1.

N-Wissen GmbH. Top Loading Autoclaves (95, 120, 135 L) Available top loading models: The Top Loading Autoclave range features:

Constant climate chambers

Washer disinfectors. > CSSD Range - Systems and Automations. devoted to hygiene. For the Environmentally conscious

AZTECA A LITRE STERILISER

Sunrise the beginning of a brand new day

Safety vacuum drying oven for flammable solvents

OPERATING INSTRUCTIONS KSG 40/60-2 KSG 50/70-2 KSG 50/80-2 KSG 50/95-2

Constant climate chamber with humidity

INSTRUMENTS. washing disinfection catalogue

Faster UltraSafe Class II Microbiological Safety Cabinets. Protection, safety, reliability. And more.

UC152 and US152. Key Features. Hotplate with Stirrer, UC152 US152. Technical Specification. Ordering Information

Version 7 1/ LX

Wash Baskets & Machine Accessories. For use in Miele Large Chamber Washers Models PG 8527 & PG 8528

BINDER Scientific Product Catalog

Getinge 8666/8668 Washer Disinfectors

Intelligent. Evaporation. Premium Safety Standards Superior Ease of Use Reduced Cost of Ownership

PASSION THAT DRIVES PERFORMANCES. WASHINGSOLUTIONS

EC 160 CO 2. Incubator

TESTING FITOTERM FITOCLIMA TEMPERATURE / HUMIDITY CONTROL REACH-IN ENVIRONMENTAL CHAMBERS FOR CLIMATE AND TEMPERATURE TESTING

Washer disinfectors Small - Medium range

laboratory & sterilization technology

Constant climate chambers

STEAM STERILIZER SERIE S1000 (RBE)

Constant climate chambers

Constant climate chambers

LTE Scientific Ltd. Touchclave-R. The dynamic new range of cylindrical-section autoclaves from LTE Scientific

Washer & Disinfector Systems

www

INSTRUMENTS. washing disinfection catalogue. washing and disinfection machines laboratory sector

camlab Choice, Service and Trust Laboratory Glasswashers and Disinfectors

1,000W (DAP-60K: 100 W per digestion vessel)

PTWS 120D USP/EP Tablet Dissolution Testing Instrument

Isotemp. Improve the productivity of your laboratory with accurate, efficient temperature control products from Fisher Scientific.

Your Health, our Technology AWD655. Instruments Washer Disinfector

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

Laboratory Glassware Washer-Disinfectors

Hotplate/stirrers. Hotplate stirrers

Thermostats designed

KMF Environmental test chamber for constant climate

INSTRUMENTS. washing disinfection catalogue. washing and disinfection machines laboratory sector

CO 2. Incubators. Incubator, the first microprocessor-based system, and the first menu-driven control system, but we offer the

The right temperature worldwide NEW. LAUDA Integral XT. Professional thermostating for pilot plant and mini-plant purposes. Product information

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Vacuum drying oven for non-flammable solvents

G 7825 Laboratory Glassware Washer. Compact Design, High Throughput

NC 100. Vertical Steam Sterilizer

External and internal circulation with powerful pumping capability

Laboratory glassware. > washing system. devoted to hygiene. For the Environmentally conscious

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

BSC CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET SERIES. Optimum protection of personnel, product and environment. BSC Class

Cold Soak Filtration Test (CSFT) of Biodiesel. ASTM D IP PM EA - CEN N CGSB 3.0 No Range

Thermo Scientific Heratherm Microbiological Incubators. safe easy efficient

O P E R A T I N G I N S T R U C T I O N S

Leading Safety Standards Superior Ease of Use Reduced Cost of Ownership. Intelligent. Evaporation

Transcription:

Laboratory- and sterilisation equipment HMC EUROPE

PROFILE Consistent marketing of technologies and the conversion of new ideas create product ranges, that are tailor-made for the requests of modern laboratories. Results of discussions with purchasers and users out of industry, chemistry, research and medicine. Quality at first place. HMC stands for competence, innovation and reliability. Whether practical and economical small tabletop sterilizers or vertical autoclaves up to 130 litres are required. HMC offers products which are used in the following areas: in biotechnology, in the agricultural economy, in the clinical laboratory and also in environmental research in biology, pharmacy and chemistry. 3

HG SERIE Page 10 HMC steam sterilizers, vertical units 50, 80, 110 and 130 litres HV SERIE Page 22 HMC steam sterilizers, vertical units 25, 50, 85 and 110 litres HMT SERIE Page 36 Laboratory- and sterilization equipment Service means serving - serving you, the customer. We take that literally! You benefit from 80 years of experience in sterilization experience you can put to work for you when looking for solutions to complicated problems and difficult tasks with limited resources. We offer simple and cost-effective solutions. And after your purchase? We deliver on time and give you a thorough introduction to your unit. From first commissioning to maintenance agreements, from qualification to validation: we are right there for you. HMC EUROPE Laboratory- and sterilization equipment HMC steam sterilizers, table top units 16 and 24 litres SAFETY CABINETS HMC Biological safety cabinets Table top units BSC 7080 WASHERS smeg Laboratory glassware washers GW 3060, GW 4090, GW 6090 CYCLONE HMC Magnetic stirrers Extremely flat Page 42 Page 44 Page 50 4 5

Why steam sterilization? The high heat storage capacity of water, the additional heat released during the condensation of steam and the moisture contained in the steam form the basis of the excellent microbiological effect of steam. By contrast with chemical sterilization or sterilization with hot air, both of which are suitable only for heat-resistant materials such as glass or metal instruments, steam sterilization is the generally accepted sterilization mode in the microbiological laboratory. From sample preparation to destruction sterilization, steam sterilizers (or autoclaves) can be used in an environmentally friendly manner. From first using... Louis Pasteur (1822-1895) Procedure The sterilization process has remained essentially unchanged since the times of Louis Pasteur and Robert Koch. Basically, sterilization is effected in a pressure vessel in an atmosphere of saturated steam in the absence of residual air. Depending on the items to be sterilized and the microorganisms to be eliminated, the sterilizing temperature will be either 121 C (1.1 bar overpressure) or 134 C (2.2 bar overpressure). To obtain a safe pressure/temperature correlation, all residual air has to be meticulously removed (vented). Sterilization is a function of temperature and time Only sufficient holding times can assure sterilization success. In microbiological laboratories, the sterilization time is usually 15 to 20 minutes. It should be noted that liquids and culture media take much longer to reach the required sterilization temperature due to delayed heat conduction. The sterilization time must be calculated from the point in time at which the core of the items to be sterilized has reached the required sterilization temperature. At the end of the holding time, the materials in the chamber will be sterile. Glass or instruments can be quickly taken out once the steam has been removed and the pressure has been released. Liquids should be cooled quickly to minimize liquid loss. The laboratory staff must never be endangered by delayed boiling (causing the liquid to overboil explosively). Since sterilizing conditions do not yet prevail in the sterilization chamber during the venting phase (because the sterilizing temperature has not been attained and the holding time has been far too short at that point), a contaminated steam/air mixture is emitted by the steam sterilizer during venting. For this purpose an exhaust-air filtration is recommended. Robert Koch (1843-1910) 6 7

...to maintenance Selection criteria What legal provisions must be complied with? Genetic engineering laws, laws concerning the prevention of epidemics... Must other provisions be met? GLP, GMP... Space requirements, minimum sterilization chamber volume Uses: Sample preparation, waste sterilization Sterilization of high infectious materials, documentation Calibration, validation, qualifications - what requirements must be fulfilled? Constructive requirements, electricity, demineralized water, disposal... Operating and secondary costs Customer service Safety, quality and price Quality has its price...... but it doesn t have to be expensive! HMC EUROPE STERILIZING SIMPLY AND WELL 8 9

HG SERIES Sophisticated yet economical functionality A large illuminated program display and easy to operate the HG series fulfils every requirement of modern sterilization units and all wishes of the user regarding functionality and comfort. And all that at a sensationally low price! Open and close at a touch - for safety reasons! Simply press a button to open and close. However, the lid is not just opening and closing. At first it is only opening for about three inches the first surge of steam is able to escape then the lid is completely open and the internal space is ready to use. While the lid is moving to the closing position, it pauses shortly before it is completely shut. When the lid is in the final position, the lock is automatically bolted. The bolt is monitored by two independent safety systems. It is impossible to open the lock unintentionally if it is under pressure. 10 11

INNOVATION Spent-steam condenser as standard A state-of-the-art condensation system with a large heat storage facility almost completely reduces the spent-steam emission during the deaeration phase. The condensate collector can be easily emptied. It is equipped with an electronic filling level indicator on the display. No water connector is required for the spent-steam condenser! Clearly arranged and illuminated The large program display makes operation simple and instantly shows the most important parameters: - Sterilizing temperature and pressure - Sterilization time - Remaining time until program end is reached The run-down display gives an overview. Configurated 3 preselected programs each for: - Liquids - AGAR sterilization, including a residual heat cycle - Solids - Steam pot programs Special programs, e.g. for Durham tubes, can be selected without any problems. Timer-controlled night-time program. Fast cooling as standard A 100% practical feature and saves up to 40% of the batch time when sterilizing liquids: an air cooling that can be switched on during all programs and at any time. 12 13

TECHNIC Safety included All HMC steam sterilizers are manufactured at a modern plant using state-of-the-art processes and technologies. The design has been approved by TÜV Bayern e.v. All units comply with all applicable European standards and regulations and bear the CE mark. Flexible temperature sensor - Thermolock Flexible temperature sensor for precision termination of the sterilization time by monitoring the media temperature. Thermolock pursuant to EN 61010-2 and related national regulations. Comfort as standard A low loading height and a smooth surface make loading and unloading a child s play. The baskets can not be caught accidentally on bolts or edges, because there are none. Modern documentation via RS232 SegoSoft process documentation, automatic paper-free archive, data output as graphics or charts in PDF format and digital signature. Double secured The locking system includes a monitoring system for pressure and temperature. Sensors monitor the safe locking of the bolt. It is impossible to open the lid unintentionally. The opening temperature (an important feature for sterilization of liquids) can be preselected from 60-97 C. 14 15

OPTIONS Vacuum generator Sterilizing in vacuum is recommended at - textiles - hollow article, tubes, bottles - porous goods as long as these can be deaerated easily - mixed materials (waste) easily accessible to steam, such as open waste bags or bins The steam generator facilitates a deep vacuum and external chamber heating. Vacuum programs comply with applicable standards and directives Extended display The 113 and 133 models have special extended control keys. Activation of pre- and drying vacuum. Extended functions USB-Port Flash Memory 16 17

TECHNICAL DATA Batch documentation Batch documentation makes processes transparent, assures quality and offers protections against legal claims. Batch printer or software for direct recording of sterilization data to demonstrate successful sterilization. Loading capacity for baskets and cans Model Basket Basket Basket Can Internal dimensions Ø x H (mm) 338 x 220 338 x 310 325 x 450 330 x 185 Round laboratory flasks 250 ml 16 32* 48* 15 Round laboratory flasks 500 ml 8 8 16 8 Square laboratory flasks 500 ml 10 10 20 10 Erlenmeyer flasks 500 ml 7 7 14 7 Erlenmeyer flasks 1000 ml - 4 8 - Modell HG-50 HG-80 HG-113 HGS-113 HGD-113 HG-133 HGS-133 HGD-133 Chamber capacity Liter 50 80 108 113 113 129 133 133 Chamber dimensions ØxH mm 364 x 482 364 x 730 500 x 552 500 x 576 500 x 576 500 x 656 500 x 680 500 x 680 Ext. dimensions W D H mm 455 x 691 x 890 455 x 691 x 1030 686 x 930 x 939 686 x 930 x 939 686 x 930 x 939 686 x 1034 x 936 686 x 1034 x 936 686 x 1034 x 936 Operating temperature C 105-135 Warming temperature C 45-60 Max. operating pressure bar 2,5 Timer 1 minute to 7 days Sterilization time from 1 up to 300 minutes Power kw 3,0 3,85 5,7 6,8 8,4 5,7 7,1 8,7 Power supply V AC 230 V / 240 V AC 400 V 50/60 Hz 3-phase Weight kg 62 73 137 153 184 145 161 192 Locking mechanism Finger-tip quicklock Safety marks CE, TÜV Bayern e.v. Boiler material SUS304 (stainless steel) Steam generator - - - Vacuum Vacuum - Vacuum Vacuum Safety features Electromechanical safety closure, safety valve, low-water interrupt, overpressure protection switch, overheating protection switch, circuit breaker, diagnostic messages (visible and audible) Extensions - - - * with rack 18 19 USB Port Flash memory USB Port Flash memory - USB Port Flash memory USB Port Flash memory Order No. 21001 21002 21003 21005 21007 21004 21006 21008

ACCESSORIES Sterilizing baskets, inserts and cans Made of electropolished stainless steel. The use of sterilizing cans is recommended for sterilizing waste and liquids. Stainless-steel sterilizing baskets and cans elektropoliert Internal dim. Ø x H Order No. Basket 338 x 220 mm 51009 Basket (closed bottom) 338 x 220 mm 51010 Basket 338 x 310 mm 51019 Basket (closed bottom) 338 x 310 mm 51023 Basket long 325 x 450 mm 51005 Can 330 x 185 mm 51007 Can (without holes) 330 x 185 mm 51008 Expansion levels and accessories Order No. Flexible temperature sensor 51001 Integrated printer 51016 Exhaust air filtration 51011 Automatic feed water connection HG 50 51012 Automatic feed water connection HG 80 51013 SegoSoft process documentation, automatic paper-free archive, data output as graphics or charts in Adobe PDF format and with digital signature. 51014 20 21

HV SERIES RELIABILITY Four sizes for your lab Whether you go for the 25, 50, 85 or 110 litre sterilization chamber model all HV series sterilizers come on wheels and offer easy handling thanks to low loading heights. The metal housing are powder-coated and easy to clean. Recessed handles facilitate easy manipulation. Heat-resistant edge beads prevent injuries. Steam condenser included. Quality included All sterilization chambers are polished and made of high-alloy stainless steel for easier cleaning. The vent valve has no dead spaces and is always safe to operate. The electrical heater directly heats the feed water for maximum efficiency and features triple protection against damage. 22 23

Safety included All HMC steam sterilizers are manufactured at a modern plant using state-of-the-art processes and technologies. The design has been approved by TÜV Bayern e.v. All units comply with all applicable European standards and regulations and bear the CE mark. Flexible temperature sensor - Thermolock Flexible temperature sensor for precision termination of the sterilization time by monitoring the media temperature. Thermolock pursuant to EN 61010-2 and related national regulations. Automatic feed water Direct connection to a supply of demineralized water (supply pressure 2 bar). Feed-water levels are checked before each sterilization cycle. Water is automatically added if required. Control unit The control unit is protected when the lid is open. It cannot be damaged by rotating or moving baskets. Display with back-lit digits and status display. No key switch required. Once a program has been activated, each step of the program is indicated in the display, together with the remaining sterilization time in minutes. The bright and easy-to-read display shows the current pressure and temperature, processing time and any troubleshooting messages. Programs can be activated only if the lock is completely closed. Exhaust-air filter - Safety for people and environment An optional accessory to ensure safe emission-free sterilization of high infectious pathogens and genetically modified materials. During the venting phase, the steam presses the non-sterile residual air from the chamber into a filtration system. Pathogens are retained and sterilized together with the content of the sterilizer and the filter cartridge (inline sterilization). Condensate sterilization is designed into the unit. Any condensate produced remains in the chamber without being removed. Exhaust air filtration is recommended for protection class / safety level L1 / S1, it is mandatory for L2 / S2 and higher. QUALITY Spent-steam condenser A spent-steam condenser condenses the steam generated by the sterilizer during the operation. This prevents fogging of instruments and unpleasant odours. All HV-L series units are equipped with an integrated spent-steam condenser and a floor discharge valve. Of course there is a floor stand for sterilizing baskets. 24 25

SAFETY Dual sensor system Our high-precision temperature control is double-checked by monitoring the pressure. This also allows a controlled temperature increase in the heating phase that shortens batch times. Batch documentation Batch documentation makes processes transparent, assures quality and offers protections against legal claims. Batch printer or software for direct recording of sterilization data to demonstrate successful sterilization. Quicklocks The simpler the design, the safer the lock! The locking lever can be actuated with one finger using little force and without damaging fingernails. It positions up to twelve pressure- and temperature-controlled bolts for opening or closing. No moving seals! The lid gasket is not subjected to any mechanical friction and can easily be replaced if required. The control unit is rotated out of the way when the lid is opened to protect it from damage. The weight of the lid is completely balanced by a torsion spring. Any condensate dripping from the lid is collected and fed into the spent-steam condenser, keeping the floor dry. 26 27

CONTROL Single-key programming The most important programs can be activated by pressing a single key: Thermolock with sterilization time control The European standard EN 61010-2 and national regulations require the use of a thermolock when sterilizing liquids. Thermolocks prevent hazards to the laboratory staff by delayed boiling. This is done by checking for the hazard at its source directly inside the potentially hazardous liquid or culture medium. The lid cannot be opened until the pressure has been equalized and the media temperature has fallen below the reference value. All parameters may be set individually before activating the program. For safety reasons, no changes to the parameter settings are possible once the program has been activated. During sterilization, the sterilization chamber is continuously post-vented. This prevents the formation of spaces with lower temperatures and of air inclusions, making sterilization a safer process. Solid sterilization: Liquid sterilization: Liquid sterilization: Liquid sterilization: Agar program: Overnight program: Waste sterilization: Standby mode: With fast steam release With variable self-cooling With rapid-cooling for thermally unstable materials With subsequent post-heating cycle Prepares agar and keeps it ready for processing (thermostatic heating) Timer-controlled - load at night, remove sterile items in the morning Mixed loads with low liquid content To save energy 28 29

RAPID COOLING Active recooling Protracted times in the sterilizer may destroy thermally unstable liquids; agar may become brown. Active rapid cooling using a fan reduce cooling times by up to 40% compared to self-cooling. This reduces batch times and allows the sterilizer to be used more efficiently, day after day. Air cooling Plug-in rapid cooling. When the sterilization time is over, the chamber is cooled with a vent. This is a a simple, cheap and effective solution. The cooling time is shortened by approximately 40% compared to self-cooling at a removal temperature of 80 C. No external connections are required. 30 31

TECHNICAL DATA Loading capacity Model HV 25 HV 50 HV 85 HV 110 Square laboratory flasks 500 ml 8 14 26 52* Round laboratory flasks 1000 ml 4 8 16-18 16-18 Erlenmeyer flasks 500 ml 4 8 16 32* Erlenmeyer flasks 1000 ml 2 6 10 10 Solids approx. kg 8 15 25 29 Waste approx. kg 8 15 25 28 * with rack Technical specifications Model HV 25 HV 50 HV 85 HV 110 Chamber volume litres 25 50 85 110 Chamber dimensions Ø x H mm 240 x 550 300 x 710 420 x 615 420 x 795 External dimensions W x D x H mm 480 x 460 x 950 540 x 530 x 1040 660 x 650 x 1000 660 x 650 x 1180 Working temperature C 105-126 105-135 105-128 105-123 Warming temperature C 45-60 Maximum working pressure bar 1,4 2,2 1,6 1,2 Special cycle C 60-100 C for culture media 32 33 Timer Sterilization time 1 minute to 7 days 1 to 250 minutes Power kw 1,5 2,0 3,0 4,0* Power supply V AC 220 V / 240 V Weight kg 41 57 71 81 Locking mechanism Mark Boiler material Safety features Single-level quicklock CE, TÜV Bayern e.v. SUS304 (stainless steel) Electromechanical safety closure, safety valve, low-water interrupt, overpressure protection switch, overheating protection switch, circuit breaker, diagnostic messages (visible and audible) Order No. 20000 20001 20002 20003 * Increased heating power on request

Sterilizing baskets and cans Made of electropolished stainless steel. The use of sterilization cans is recommended for sterilizing waste and liquids. OPTIONS Expansion levels and accessories Order No. Flexible temperature sensor 50001 Air cooling RL 50002 Integrated printer 50003 Exhaust-air filtration 50004 Automatic feed water connection 50017 PT 100 temperature-sensor for external printer or SegoSoft software 50005 GLP package consisting of integrated printer and exhaust-air filtration 50021 SegoSoft process documentation, automatic paper-free archive, data output as graphics or charts in Adobe PDF format and with digital signature. Lifting device HV 85, (Lift with swivel arm, load and unload of baskets up to 30 kg) Lifting device HV 110, (Lift with swivel arm, load and unload of baskets up to 30 kg) 50031 50032 50033 Beschickungskörbe aus Edelstahl electropolished internal dim. Ø x H mm Order No. HV 25 225 x 250 50006 HV 50 280 x 225 50007 HV 85 390 x 290 50008 HV 110 390 x 380 50009 Stainless-steel sterilizing cans electropolished internal dim. Ø x H mm Order No. HV 25 225 x 260 no holes 50010 HV 50 280 x 220 no holes 50011 HV 85 390 x 285 One row of holes (lower third) 50012 HV 110 390 x 375 Two rows of holes (lower third) 50013 34 35

State of the art All HMT steam sterilizers are manufactured at a modern plant using state-of-the-art processes and technologies. All units comply with the Pressure Equipment Directive and all applicate European standards and regulations and bear the CE mark. HMT SERIES Automatic program sequence While in the case of HMT 232 X, one out of four different sterilization times can be selected, the units of the FA class offer preselected programs with an automatic, microprocessor-controlled program sequence, including an automatic feed water out of the reservoir. Safety included All HMT steam sterilizers are equipped with an overpressure protection switch, a safety valve and an overheating protection switch. The door is locked manually by a turning bolt. As a matter of course, the unit is equipped with a water-level monitor for the reservoir and the sterilization chamber, using a visible and audible warning message in case of low water. 36 37

TECHNICAL DATA Technical data Model HMT 232 X HMT 230 FA HMT 260 FA Chamber volume litres 16 16 24 Chamber dimensions Ø x H mm 230 x 410 230 x 410 260 x 450 External dimension W x D x H mm 500 x 406 x 537 522 x 410 x 594 533 x 442 x 655 Working temperature C 121-134 121-134 121-134 Pre-selection of sterilisation time min 4, 15, 30 Automatic program sequence incl. feed water out of reservoir, 9 preselected programs, microprocessor-controlled Power kw 1,4 1,9 2,4 Power supply AC 220 V / 240 V Weight kg 31 48 53 Safety marks CE Safety features Overheating protection switch, safety valve, overpressure protection switch Overpressure protection switch, safety valve, overheating protection switch, lock, water-level monitor for reservoir and sterilization chamber Chamber capicity Model HMT 232 X HMT 230 FA HMT 260 FA Round laboratory flasks 50 ml 24 23 46 Round laboratory flasks 100 ml 18 15 30 Round laboratory flasks 250 ml 9 11 15 Erlenmeyer flasks 250 ml 9 11 15 Erlenmeyer flasks 500 ml - 3 6 Square laboratory flasks 500 ml - 4 8 Tray frames Order No. HMT 232 X 52009 for various insertion heights, HMT 230 FA 52014 trays included HMT 260 FA 52019 Set HMT 232 X 52023 for various insertion heights, Set HMT 232 X 52024 trays included Set HMT 232 X 52025 Order No. 22001 22004 22005 Trays Order No. HMT 232 X 52008 HMT 230 FA 52013 HMT 260 FA 52018 Sterilisation box Dimensions W x D x H Order No. HMT 232 X Insert with lid, side 183 x 135 x 345 52007 HMT 230 FA panels with boring that 183 x 135 x 345 52012 HMT 260 FA can be closed 228 x 140 x 375 52017 38 39

Bio safety cabinets Bio safety cabinet BSC-700II This miniature Class 2 safety workbench offers security on a minimum of space. The protection of the user as well as the safety of the samples is ensured by the two HEPA filters with an efficiency of 99.995% at 0.3 microns. Contamination of the working area is avoided due to 70% of circulating air, of which 30% are emissive. An air-flow gauge (velometer) monitors the speed of air at the front and will activate an alarm (audiovisual), if the fan malfunctions. The unit may be placed on a desk without any problems. Therefore, it is easily and quickly assembled in a laboratory at a moment s notice. The use of the unit is very easy and fool-proof. On pressing a button, the sliding tempered glass is going up and down; it is locked in every possible position. The sockets, the working area light and the UV light can be connected to the unit by pressing a button. However, the UV light is only switched on when the sliding tempered glass is closed, while the fan, which is also activated by pressing a button, is only switched on when the sliding tempered glass is opened. Delivery: unit, complete with 2 HEPA filters, UV light, two disengageable sockets, stainless-steel working surface and instruction manuals. Standard features Electrical sliding window UV light, to be positioned freely 2 sockets, can be disconnected from outside Electronically controlled air stream Automatic readjustment of fan Stainless-steel working surface Quiet fan drive with low vibration Digital air flow indication Main switch as key-operated switch Technical data Model BSC-700II Dimensions W x D x H mm 700 x 650 x 1230 Workspace W x D x H mm 600 x 500 x 540 Air cleaner HEPA filter mm 600 x 370 x 69 Exhaust air HEPA filter mm 540 x 340 x 69 Efficiency % 99999 Circulating air % 70 Exhaust air % 30 Control system Microprocessor Tempered glass multi-layer toughened glass Material workspace 304 Stainless steal Clean Level Class 10 Acoustic level db 65 Vibration μm 5 Power supply V Hz AC 230/ V 50Hz Consumption W 800 Light lux > 680 Input Airflow m/s 0.53 Output Airflow m/s 0.33 Order No. on request 40 41

Laboratory Glassware Washers smeg - Innovative, safe and reliable for more than 20 years Smeg Instruments, as a part of the Smeg Group is represented by eleven branch offices world-wide and is one of the brand leaders in laboratories. Since 2010, HMC Europe is the exclusive sales and service representative of Smeg Instruments in Germany. Washing and disinfecting in technical perfection The professional series of Smeg laboratory glassware washers are a reference in quality and equipment. They meet the requirements of laboratories operating in the general chemical, organic and petrochemical fields. For laboratories operating in the biological sector, Smeg Instruments guarantees complete biological decontamination according to the BGA standard. 42 43

OPTIONS Standard fittings Washing interior 316 L stainless steel High-grade plastic parts/rubber seals Microprocessor controlled Programmable washing cycles Peristaltic pumps with level sensors Detergent storage Rapid-Drying-System RS232 Interfaces Noise emission <50 db Standards 2006/95/EWG, 93/68/EWG, 2004/108/EWG EN61010-1, EN61010-2-040, EN61326:1997+A1:1998 Accessories Printer Software for external programming / controlling Pumps and valves Steam condenser / Rapid-Drying-System Spraying and injection levels Inserts, fixings, baskets, trolleys, supports, bottom racks and spigots 44 45

TECHNICAL DATA Drying systems Model GW3060 GW4090 GW6090 Drying fan 0,4 kw 0,8 kw Drying heating element 2 kw 4 kw Prefilter class C 98% 98% HEPA filter Class S 99,999% 99,999% Drying air temperature 75 C-100 C 75 C-100 C Cold/hot water hardness max. 42º F max. 42º F max. 42º F Demineralised water conductivity < 20 μs / cm < 20 μs / cm < 20 μs / cm Demineralised water pump on request Recirculation pump 400 l/min 400 l/min max. 2 x 400 l/min Model GW3060 GW4090 GW6090 Electronic control Li 3 microprocessors +1 (optional communication card) Programs 20 standard programs stored / 10 settable programs (expandable to 50) Display Backlit graphic LCD display 128 x 64 pixels Parameters Clock and calendar Phases 10 reprogrammable phases Phase parameters type of water, detergent quantity, target temperature, extension time in minutes, drying temperature and time Tank internal temperature C 5 to 95 Accuracy C 0.1 Temperature sensors in tank PT 1000 KLASSE B IEC 60751 Feed pumps (50 ml/min) max. 4 max. 4 4 Safety lock with electromagnetic release Safety devices safety thermostats, door interlock Languages Italian, English, French, German (on request: Spanish, Polish, Swedish, Russian, Japanese) Water heating kw max. 6,3 kw max. 6,3 kw 18,5 kw Steam condenser GW3050BXC, GW3050SC, GW3050PC on request (standard at GW4090C ) Dimensions outside LxTxH mm 900 x 640 x 850 (830 as fitting) 900 x 640 x 850 (830 as fitting) 2035 x 801 x 902 Dimensions inside LxTxH mm 520 x 515 x 545 520 x 515 x 545 670 x 650 x 835 Weight kg 120 120 282 Material wash tank stainless steel AISI 304 Exterior covering stainless steel AISI 304 Max. voltage / power 3/N/PE 400V ~ 50Hz 7,0 kw 3/N/PE 400V ~ 50Hz 7,0 kw 3/N/PE 400V ~ 50Hz 18,5 kw Order No. HMCCL3090 HMCCL 4090 HMC6090 46 47

Innovative technology In a coil system, rotating magnetic fields are produced through electronics, which drive the well-known magnetic stirring bars inside the bottles. At the same time, the electronics provides that there is always enough magnetic power available to mix reproducible aqueous solutions. Application areas Extremely flat electronic multipoint magnetic stirrer without moving parts. For the flexible use in the laboratory. Cyclone 6 Electronic multipoint magnetic stirrer with 6 stirring points Extremely flat without moving parts Microprocessor-controlled Elegant design with stainless-steel housing 6 synchronically working stirring points, for example 6 x 1 litre Erlenmeyer flasks Cyclone 15 Electronic multiposition magnetic stirrer with 15 stirring points Extremely flat without moving parts Microprocessor-controlled Elegant design with stainless-steel housing 15 synchronically working stirring points, for example for 15 x 250 ml glasses Ideal device for mass screenings Speed range 100-1000 rpm Technical data Model Cyclone 6 Cyclone 15 Stirring points 6 15 Distance between stirring points mm 130 65 Stirring volume ml 1-1500 1-1000 Stirring power W 5-20 Speed range 1/min 100-1000 Dimensions W x D x H mm 240 x 420 x 35 Weight (stirring drive) kg approx. 7,5 Operating voltage VDC 12 Housing material Stainless steel Protection acc. to DIN 40050 IP 66 Ideal device for mass screenings Control cable m 1,9 1,9 Hermetically sealed Speed range 100-1000 rpm Permitted ambient conditions C -10 up to +56 at 100% humidity Simple operation Hermetically sealed Operation direct Indestructible Simple operation Incl. power supply unit Power supply unit Indestructible Order No. 90001 90002 48 49

Cyclone 1-60 Flat electronic single-position magnetic stirrer without moving parts Cyclone 1-150 Flat electronic single-position magnetic stirrer without moving parts EFFECTIVENESS For stirring volumes up to 1200 ml For stirring volumes up to 700 ml Remote-controlled single-position magnetic stirrer, stainless steel housing Hermetically sealed, for use in apparatus and water baths Remote-controlled single-position magnetic stirrer, stainless steel housing Hermetically sealed, for use in apparatus and water baths Stirring drive, diameter 150 mm, height 25 mm Stirring drive, diameter 60 mm, height 25 mm, integrated Integrated M4-threaded bore for attaching the M4-threaded bore for attaching the magnetic stirrer at magnetic stirrer at the bottom of housings the bottom of housings Inclusive control unit CycloPower with 20 or 7 watt, Inclusive control unit CycloPower with 20 or 7 watt, continuously adjustable, cable 1.9 m Model Cyclone 1-60 Cyclone 1-100 Cyclone 1-150 continuously adjustable, cable 1.9 m Protection class DIN 40050 IP 68 Stirring points 1 Protection class DIN 40050 IP 68 Stirring volume ml 1-1000 1-1000 1-1200 Stirring power W 5-20 Speed range 1/min 100-1000 Dimensions Ø mm 60 100 150 Weight (stirring drive) g 160 270 400 Cyclone 1-100 Operating voltage VDC 12 Flat electronic single-position magnetic stirrer without moving parts Housing material Stainless steel For stirring volumes up to 1000 ml Protection acc. to DIN 40050 IP 68 Remote-controlled single-position magnetic stirrer, stainless steel housing Control cable m 1,9 Hermetically sealed, for use in apparatus and water baths Stirring drive, diameter 100 mm, height 25 mm Permitted ambient conditions Operation C -10 up to +56 at 100% humidity remote controlled Integrated M4-threaded bore for attaching the Control unit W optionally CycloPower 7 (7 Watt) or CycloPower 20 (20 Watt) magnetic stirrer at the bottom of housings Order No. with CycloPower 20 90003 90004 90005 Inclusive control unit CycloPower with 20 or 7 watt, continuously adjustable, cable 1.9 m Protection class DIN 40050 IP 68 Order No. with CycloPower 7 90022 90023 90024 50 51

WATERBATH Model CycloSub 6 CycloSub 15 Number of stirring points 6 15 Distance between stirring points mm 130 65 Stirring volume per stirring points ml 1-1500 1-1000 Stirring power W 5-20 CycloSub 6/15 HMC CycloSub 6/15 Speed range rpm 100-1000 100-1000 In a coil system, rotating magnetic fields are Magnetic stirrer without moving parts External dimensions W x D x H mm 240 x 420 x 35 produced through electronics, Remote-controlled multi-point Weight (stirring drive) kg aproxx. 7.5 which drive the well-known magnet stirring magnetic stirrers with simple operation bars in the bottles. Operating voltage V 12 Microprocessor-controlled Construction At the same time the electronics provides Elegant design with stainless-steel housing that there is always enough magnet power Material stirring drive stainless steel available to mix reproducible aqueous 15 or 6 synchronically working stirring points Protection acc. to DIN 40050 IP 68 solutions. The devices are sealed hermetically These magnetic stirrers are ideally suited for Controlling cable (length) mm 100 200 (lower surface covered with silicone). mass screenings, biotechnological, chemical Environment conditions Ideally suited for operation directly in or and medical applications Environment temperature C -10 until + 56 in 100% air damp below the water bath (up to +50 C) Easy-to-clean housing with no cracks, joints or edges Operation remote controlled Space-saving and a safe low-voltage device, Incl. universal power supply unit Power supply unit these units are a must-have in any laboratory Frequency Hz 50-60 Supply voltage VAC 100-240 Acrylic water bath Variations Order No. External dim. acrylic water bath W x D x H mm 540 x 310 x 210 CycloSub 6 W CycloSub 6, CycloPower 20, incl. waterbath CycloBath 90030 Internal dim. acrylic water bath W x D x H mm 515 x 255 x 160 CycloSub 6 WT CycloSub 6, CycloPower 20, incl. waterbath CycloBath, CycloTherm thermostat 90040 Environment temperature C -10 until + 50 CycloSub 15 W CycloSub 15, CycloPower 20, incl waterbath CycloBath 90031 Weight kg 4 CycloSub 15 WT CycloSub 15, CycloPower 20, incl. waterbath CycloBath, CycloTherm thermostat 90041 Order No. with acryl-waterbath 90032 90033 Order No. without acryl-waterbath 90030 90031 52 53

OPTIONS Model CycloPower 7 CycloPower 20 Rotation speed range rpm 100-1000 Nominal power W 7 20 Dimensions W D H mm 6,5 x 10 x 7 14,5 x 13 x 5,5 Weight kg 0,35 0,6 Perm. ambient temperature C 0 up to +40 at 80% relative humidity Input voltage / Frequency 230 VAC / 50-60 Hz Output voltage VDC 19 Order No. 90020 90021 HMC EUROPE Laboratory- and sterilisation equipment Accessories Order No. Magnetic stirring bars 90008 CycloBar 25/8 T Triangular magnetic bars, dimensions: 25 x 8 mm 90009 CycloBar 25/14 T Triangular magnetic bars, dimensions: 25 x 14 mm 90010 CycloBar 40/14 T Triangular magnetic bars, dimensions: 40 x 14 mm 90011 CycloBar 50/12 T Triangular magnetic bars, dimensions: 50 x 12 mm 90012 CycloBar 110/36 T mega Triangular magnetic bars, MEGA, dimensions: 110 x 36 mm 90013 CycloBar 57/27 C mega cyl. Cylindrical magnetic bars MEGA, dimensions: Ø 27 mm x 57 mm (L) 90014 CycloBar R 25/6 C cyl. Cylindrical magnetic bars rare earth, dimensions: Ø 6 mm x 25 mm (L) 90015 CycloBar R 40/8 C mega cyl. Cylindrical magnetic bars rare earth, dimensions: Ø 8 mm x 40 mm (L) 90016 CycloBar R 25/8 T mega cyl. Cylindrical magnetic bars rare earth, dimensions: Ø 8 mm x 25 mm (L) 90017 CycloBar R 40/14 T mega cyl. Triangular magnetic bars, rare earth, dimensions: 40 x 14 mm 90038 CycloBath, Acryl-Watherbath Dimensions D x W x H in mm: external 540 x 310 x 210, internal 515 x 255 x 160 90039 CycloTherm Immersion Thermostat 54