Temperature Control for

Similar documents
Guide To Troubleshooting INEFFICIENT COOLING FANS

TOP 29 QUESTIONS PROSPECTIVE ENCLOSURE COOLING THERMAL EDGE CUSTOMERS ASKED BY Thermal Edge, Inc

THE ULTIMATE GUIDE TO ENCLOSURE COOLING FOR WATER TREATMENT. The Ultimate Guide to Enclosure Cooling for Water Treatment

Ambient (ºF) Temperature Rise Above

ENCLOSURE COOLING. Glossary

32 Tips to Consider Before Purchasing an Electrical Enclosure Air Conditioner TABLE OF CONTENTS INTRODUCTION... 3 TECHNICAL FEATURES 4

L14 ENVIRONMENTAL CONTROL TECHNICAL DATA

Cabinet Cooler Systems

Enclosure Temperature Control

How to Select and Size Enclosure Thermal Management Systems: White Paper, Title Page. How to Select and Size Enclosure Thermal Management Systems

Enclosure Temperature Control

Hunting the Mighty Milliwatt- The next Technology Step

Important Considerations When Selecting a Fan for Forced Air Cooling. By: Jeff Smoot, CUI Inc

OWNER S MANUAL. Geothermal Heat Pumps. Product Family: HB, HP, HS, HW A NOTE ABOUT SAFETY ! WARNING YOUR NEW SYSTEM. Register Your System

SYNOPSIS. Part-Load Control Strategies for Packaged Rooftop Units. In this issue... Bin Hour Profile Charlotte, NC

TOTAL SYSTEM EFFICIENCY: AN INTRODUCTION TO CONDENSING BOILERS. David Grassl PE Mechanical Engineer Principal

Optimal Use of Air Conditioner

dissipation: air conditioning, compressed air and heat exchangers. Air conditioning was

NOREN Products. Compact Cabinet Coolers

Q1. The diagram shows the design of a solar cooker. The cooker heats water using infrared radiation from the Sun.

Instruction Manual. gray Mounted Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Instruction Manual. gray Housed Detectors. for. greenteg AG Technoparkstrasse Zürich, Switzerland T: F:

Radiant Heating. Systems

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

5CONSIDERATIONS WHEN SELECTING A DESICCANT BREATHER FOR YOUR EQUIPMENT

Desiccant Breathers: A Front Line Defense in the War on Contamination

So far, we have covered the basic concepts of heat transfer and properties.

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

Your Global Automation Partner. Minimizing Arc Flash Exposure in Industrial Applications. White Paper - W1000

Laird Engineered Thermal Systems Application Note. Liquid to Liquid Ambient Cooling Systems for Semiconductor Tools

Multi-Unit Residential Buildings

CONTROLLING BOILER SWELL AND SHRINK

Construction Electrical

Guide to the Heating and Cooling Systems at McLean Gardens

CORTEC. CORTEC

How to Select an Industrial PC with I/O for a Wide Temperature Application

COOLING FOR ELECTRONIC PROCESS CONTROL SYSTEMS IN HOSTILE FACTORY ENVIRONMENTS

Transfer of Thermal Energy

Induction Furnace Cooling Systems

EMERGING NEEDS FOR CORROSION CONTROL AND PREVENTION THROUGH DESICCANT DEHUMIDIFICATION

Vortex Enclosure Coolers A/C ATEX

More heat energy means more of what type of energy? Does the mass change? So, what must change? What is the same in both containers?

1. What are the scales of temperature? What are the formulas to convert among them? Fahrenheit, Celsius, Kelvin

Energy Efficient Enclosure Climate Control

Application Guide. IIoT enabled Intelligent Battery Management

KOOLTRONIC ENCLOSURE AIR CONDITIONER QUICK SHEET

Drying principles and general considerations

The Art of Building Science

Trials Tribulations & Rewards High T Heating Systems

Commercial Buildings Chilled water systems efficiency By Jens Nørgaard, Senior Application Manager, Grundfos, Denmark

CombustionONE. Improving and Sustaining the Combustion Asset. Driven by the New Standards. Bulletin 53A90A01-01E-A

CPC PRODUCT DESCRIPTION

TOTAL SYSTEM EFFICIENCY: SYSTEM APPLICATIONS & DESIGNS. David Grassl PE Mechanical Engineer Principal

Electrical. Bi-Metallic Thermal Cutouts. Linear Thermal Cutouts

HEAT PIPES

Minimizing Corrosion in SRU Vapor Lines

SEL Arc-Flash Solutions

Guidelines for Optimizing Drying and Blow-Off Operations

ELECTRO STATIC PRECIPITATOR [ESP]

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Hunting the Mighty Milliwatt The next Technology Step

Solar water heating system

WELCOMES CUSTOMERS AND BUSINESS PARTNERS

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

PHYSICS FORM 5 TRANSFER OF THERMAL ENERGY

Refrigerant Transfer and Compressor Damage

- Essay Control Functions and Benefits

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Laird Thermal Systems Application Note. Bi-directional Microcontrollers Monitor and Protect Medical Equipment

COOLING SPECIFIER S GUIDE EQUIPMENT PROTECTION SOLUTIONS COOLING

INK CURING TIPS TIPS & TECHNIQUES

Compressed. air treatment. Refrigerated. compressed air. dryers. Totally Integrated. compressed air. treatment.

SEL Arc-Flash Solutions

Fundamental Principles of Air Conditioners for Information Technology

- Data Brochure Universal Reset Module 422

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

MultiPlex INNOVATIVE COMPRESSED AIR SOLUTIONS LARGE CAPACITY TRUE-CYCLING TM REFRIGERATED COMPRESSED AIR DRYERS

BGH Series Hot Surface Ignition Control

COMPANY INTRODUCTION

17 Interior Climate Control

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

Identify the key elements of the laser source, regardless of the type of measurement or sensor required;

Fourth Edition HEAT TRANSFER AND CHANGE OF PHASE

APC APPLICATION NOTE #109

TOCOS. Guidelines & Precautions. For Using Trimmer Potentiometers. Guidelines for Circuit Design. Guidelines for Production Processes

Microwave Heating. Module- 21. Lec- 21. Dr. ShishirSinha. Dept. of Chemical Engineeriing. IIT Roorkee

Installation and Operation Manual. ACF-18 Automatic Chlorinating Feeder

A student investigated how much energy from the Sun was incident on the Earth s surface at her location.

Webinar November 12, 2014

The Emergence of Triboelectric Technology

CTI Sponsored Educational Program

Exciting Swiss temperature control technology, distributed in North America exclusively by...

CO2 TRANSCRITICAL BOOSTER SYSTEMS

GM Ultrasonic Gas Leak Detection Gas Detection at the Speed of Sound. How fast does your Gas Detection System detect leaks?

- Data Brochure Universal Reset Module 423

How to ensure Thermal Comfort in buildings with CFD

Temperature & Heat Heat is a type of energy. It is measured in joules (J).

Heat Exchanger. The purpose may be either to remove heat from a fluid or to add heat to a fluid.

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

Effects of Ultra-High Turndown in Hydronic Boilers By Sean Lobdell and Brian Huibregtse January 2014

Transcription:

Temperature Control for Electrical Enclosures: Why You Can t Ignore It

Introduction Electrical equipment is almost always specified by manufacturers for operation within an optimal temperature range in which the equipment s reliability, performance, efficiency, and physical integrity are protected. At higher temperatures, the efficiency of equipment decreases and component damage or even failure may result. A modern VFD typically has an efficiency of 93-97 percent 1 and is designed for operation below 40 C (104 F) 2. For every degree increase above the operating temperature, efficiency is derated by 2 percent. In addition to an increased risk of equipment failure, high operating temperature has resulted in long-term costs due to decreased reliability and lifespan. For a business, this could mean unexpected costs associated with frequent maintenance, component failure, additional downtime for spare parts, and, in some cases, replacement of the entire system. Fortunately, this added cost, which can range from tens of thousands to hundreds of thousands of dollars, can be avoided with a little foresight by including a temperature control system in specifications. 2

Temperature Related Causes of Electrical Equipment Damage The lifetime and failure-free operation time of electrical equipment is strongly dictated by environmental conditions and the mode of operation. Each component or type of electrical equipment has its own maximum operating temperature as specified by the manufacturer. For instance, variable speed drives, contactors, and power supplies can operate between 40 C (104 F) and 50 C (122 F); electrical batteries, have a lower temperature threshold of 30 C (86 F) 3. High operating temperature can increase the potential dangers to equipment operation. Some of the common risks associated with high internal heat are: Unexpected Equipment Shutdown Some manufacturers program equipment components to toggle off at high temperatures. Deteriorated Equipment Performance High temperature can cause erratic equipment performance, often leading to undesirable results. VFDs are derated for operation at temperatures above their normal range. The accepted standard has been derating drive efficiency by 1% for every degree above 40 C. Equipment Damage Equipment operating at beyond its manufacturer-specified operating temperatures can become damaged, often requiring repair or even replacement. PLCs and electrical loop controllers do not have high temperature tolerance. Shortened Equipment Life Constant exposure to high temperature intensifies aging of equipment. Components work harder at high temperature and, thus, experience more wear-and-tear, resulting in shortened equipment lifetime. 3

Fire Hazard Rare but not uncommon, excessive heat inside an enclosure could result in melting of equipment parts and even fire. Most manufacturers emphasize the effect of temperature on their equipment by including a performance-derating factor for high-temperature operation. Therefore, identifying the most critical component and controlling the temperature to match the component s operating temperature range is important. Low-temperature environments have a different effect on electrical equipment. The two main areas of concern for equipment operating at low temperature are safety and function. The common risks associated with low temperature are: Equipment Startup Issues Starting motors and variable frequency drives at low temperatures is difficult because oil and grease lose their lubricating properties. Material Properties Low temperatures have a dramatic effect on material properties particularly plastics and elastomers used in the construction of electrical equipment thus making them unsafe and unsuitable for use. Arcing Due to Condensation Water vapor in the air condenses at low temperature. Insulators lose their properties at low temperature. The combined effect of conductors in contact can cause arcing issues and increase the risk of fire. Ice Formation Formation of ice on the equipment casing increases the risk of short circuiting and breakdown of electrical circuitry. Humidity: A Consequence of Fluctuating Temperatures Manufacturers typically specify a relative humidity of 60% ± 30% at a temperature of 30 C (86 F) to 40 C (104 F) without the presence of condensation for normal operation of electrical equipment 4. Though outdoor equipment is more threatened by humidity and condensation, indoor equipment in highly humid locations is also susceptible to failure without a proper condensate management system. Humidity in the enclosure can be detrimental to electrical equipment in the following ways: Corrosion Water in contact with unprotected metallic surfaces of electrical equipment causes corrosion. Corroded joints in sensitive equipment may be irreparable, thus requiring replacement and ramping up costs. Electro-Migration The presence of an electric field and moisture can cause electro-migration that can be seen as the formation of pits and dendrites on metal surfaces in contact with an insulator. Moisture Absorption Polymers used in electrical equipment for insulation purposes lose their properties when they absorb moisture in the air. This can expose the equipment to a variety of problems. 4

Short-Circuiting Moisture in the air (usually mixed with particulate matter) is a good conductor of electricity. When water droplets come in contact with electrical circuits, they can cause short-circuiting or total breakdown of the circuit components. Premature Aging Humidity increases aging of equipment by increasing the rate of wear-and-tear of components. Where Is Enclosure Heat and Humidity Generated? Temperature control is critical in protecting electrical equipment, but what factors contribute to heat and humidity and should be accounted for in specifications? Heat Load from the Electrical Equipment The primary source of heat comes from the electrical equipment itself within the enclosure. How does your electrical equipment generate heat? As you know, the second law of thermodynamics puts a limit on the amount of useful work that can be derived from a machine; it follows that no system can operate at 100 percent efficiency. Thus, the remaining energy is used to overcome friction or released into the environment as lost heat. This lost energy increases the temperature of the enclosure air and the temperature of the components of your equipment, thus creating a vicious cycle of heat generation. For instance, a 10 kw variable frequency drive dissipates over 300 W (1025 BTU/hr) of heat within an enclosure. Assuming a medium-sized enclosure has the dimensions of 48 36 16, there is a temperature increase of 30 F within the enclosure 5. 5

Heat Transfer from the Environment The secondary source of heat load in an enclosure comes from the environment. The common sources of external heat are: Heat Transfer Due to Ambient Temperature When the external ambient air is hotter than the equipment s operating temperature, heat transfer will cause an increase in the enclosure s internal air temperature. The rate of heat flow depends on the magnitude of the temperature difference and the enclosure s material and medium of insulation lining. To put this in perspective, a temperature difference of 15 F between the enclosure air and ambient air can contribute to 5.1 BTU/H for every square foot of surface area of your enclosure. Assuming a medium-sized enclosure, this translates to almost 220 BTU/H of additional heat that must be dissipated to the external air. Solar Heat Gain The incident radiation from the sun can cause a dramatic increase in internal temperature of an outdoor enclosure. The extent to which solar heat gain can increase enclosure temperature depends on factors such as the location of the enclosure, insulation coating on the enclosure, color and texture of the enclosure outer body, ambient temperature and humidity, air composition in the location, altitude, and wind parameters. Assuming there is no internal heat from equipment, to maintain a mediumsized black outdoor enclosure at ambient temperature, 1308 BTU/hr of heat would need to be eliminated. With a gray outer body, you would have to dissipate only 838 BTU/hr. Equipment Located in the Vicinity of the Enclosure Indoor and outdoor enclosures are commonly located alongside other equipment. The thermal footprint of industrial equipment such as blast furnaces, industrial ovens, and foundry equipment in the vicinity of the enclosure can increase its internal temperature. 6

Why Natural Convection Can t Perform a Job Needing Active Cooling A general misconception is assuming the heat dissipated by the equipment is not significant enough to warrant the installation of an active temperature control system. More often than not, engineers eliminate heat by increasing the size of the enclosure and/or adding a ventilation system that makes use of natural convection. Surprisingly enough, although this is the lower-cost option, it is an insufficient method for many applications as equipment evolves to require active temperature control. There are several impediments to using natural convection as a solution to enclosure temperature control, including: Hot Spots Heat inside an enclosure rises to the roof. Without a ventilation system that accounts for this, there will be a temperature differential between regions inside the enclosure. This phenomenon can result in thermal hot spots that can spiral into a cascading temperature increase in these regions. Hot spots are undesirable because they could lead to temperature related equipment failure. Absence of Early Warning The absence of an active cooling system makes it impossible to cool the enclosure to below ambient temperatures. This can result in poor equipment performance and even failure if the ambient temperature is higher than the specified operating temperature of the equipment. Further, high heat inside enclosures cannot be recognized immediately because natural convection does not use metrological equipment or digital controllers to send out high-temperature alarms. Environmental Limitations Natural convection relies too much on wind patterns, indoors and outdoors. Consequently, any change in wind pattern can result in insufficient cooling of the enclosure. The reliance on air for natural convection extends to air composition as well. Enclosures located in harsh environments such as petrochemical plants or coal mines cannot depend on natural convection for efficient cooling because it can result in contamination of the enclosure. The use of filters with natural convection is limited because there is nofan to actively move air through the enclosure. There is an inherent pressure drop in the flow that is associated with all filters: the finer the filter, the greater the pressure drop. For natural flow, any impedance to results in a reduction of air flow; therefore, the choice of filters is limited to coarser filters. Lastly, some applications require sealed enclosures, in which case a closed loop cooling system is mandatory. Natural convection requires larger enclosures and an effective ventilation system that allows cool, clean and dry air for heat dissipation. Space constraints and extreme ambient conditions may prove unfavorable for natural convection to cool the enclosure. 7

What a Temperature Control System Can Do for You Temperature control solutions range from simple filtered fans to heat exchangers and air conditioners. The choice of a solution depends on the application itself. Depending on the sophistication of the solution and application requirements, the costs vary. For instance, a filtered fan is suitable for use in applications requiring low to moderate heat dissipation, located in a cool, clean and dry air environment. For extreme conditions and hazardous locations such as coal mines and petrochemical plants, an air-to-air heat exchanger or an air conditioner that has been designed for operation in such conditions would be required. No matter the application, an efficient temperature control system improves reliability and lifespan of the enclosure system by: About Thermal Edge Thermal Edge manufactures cutting-edge temperature control solutions to handle electrical enclosure cooling requirements. Our temperature control products include filtered fans, air-to-air heat exchangers, air conditioners, and custom enclosure system packages. We at Thermal Edge provide comprehensive, highly efficient air conditioners with a fully integrated energy saving condensate management system. Our innovative designs are packaged with a thermal expansion valve that enables our air conditioners to operate over a broad temperature range and adapt to fluctuating heat loads at a higher efficiency. Controlling the temperature within the enclosure to meet the operating temperature requirements of the most critical component Minimizing pollutants, dispersed oil, and moisture from the air inside the enclosure With some manufacturers, reducing humidity and handling the condensate in an efficient manner that does not require water drains or energy consumption Enabling you to monitor and control the enclosure temperature and air conditioner performance remotely Efficiently protecting equipment from possibly hazardous ambient conditions Reducing utility costs associated with lowefficiency performance of equipment at high temperatures Minimizing maintenance costs and the need for repair and replacement of components Eliminating costs of failed equipment that result in downtime 8

If you need help selecting the right temperature control solution for your application, talk to the professionals at Thermal Edge. Our experts will work with you from beginning to end to ensure that you have the most cost-effective solution for your application. We also work with engineers who design electrical enclosures to help determine the right temperature control solution early in the design process. Get in touch with us today to review case studies that are similar to your application, review product literature, or schedule a consultation. references 1 Wilson, Doug. Determining the Panel Heat Load. Plant Services. N.p., 2010. Web. 2 Installation Manual. Franklin Control Systems (n.d.): n. pag. Print. 3 Control Panel Technical Guide. Schneider Electric (n.d.): n. pag. Web. <http://www2. schneider-electric.com/documents/interactive-publications/thermal-management-solution/ control_panel_technical_guide/files/docs/all.pdf>. 4 Condensation in Electrical Enclosures. Schneider Electric Blog. N.p., 28 Oct. 2013. Web. 01 May 2015. 5 Adjustable Speed Drive Part-Load Efficiency. Washington, D.C.: United States. Dept. of Energy, 2008. Web.