Print Specification. Publication. Instructions. Specific requirements. General requirements

Similar documents
SIGA-CC1 Single Input Signal Module Installation Sheet

Signature Series Auto-Sync Output Module (CC1S)

FX-PDD Duct Smoke Detector Installation Sheet

Signature Series Component

Addressable NAC Output Module D327A

Control Relay Modules

ACC-25/50ZST. Zoned System Voice with Telephone Evacuation Control Panel

Booster Power Supply Manual

Genesis Low Frequency (520 Hz) Horn-Strobe Installation Sheet

LifeAlarm Fire Alarm Controls

SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

D326A/D334A/D339A. Installation Instructions. Point Contact Modules

SC-6 Six Supervised Control Module

System Accessories, LCD Annunciators

Notification Appliance Circuit Module

E-PDD Duct Smoke Detector Installation Sheet

R-Series Remote Annunciators and Expanders Installation and Operation Guide

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

PSN-1000 & PSN 1000(E) Installation Manual

ECC-50/100C. Emergency Command Center

ECC-50/100(E) Emergency Command Center

These instructions detail procedures to follow in order to avoid damage to equipment.

TrueAlert Addressable Notification

/5121/5122 TrueAlert Power Supply Installation Instructions

Multi-Application Peripherals and Accessories

Product Guide. Fire Alarm Cables. Initiating Device, SLC Lines, and NAC Cables.

Fire Alarm Wiring. Circuit types, styles and limitations

Addressable Detectors & Bases

Multiple Input and Output Modules

30.45 Electric Release PDRP-2001

UEI-1 UNIVERSAL END-OF-LINE / ISOLATOR TESTER

FireNET Plus Wiring Instructions

MR-2602 Two Zone Fire Alarm Control Panel

Rev. B. TrueAlert Addressable Controller Application Manual

SAFEPATH SP40/2 D10 D35 AMP P/N P/N Installation, Testing, TONE SW Operation, and W4 Maintenance D54 SHORT

CZ-6A Six Zone Interface Module

SECTION FIRE ALARM SYSTEMS

SHORT CIRCUIT ISOLATOR TO NEXT COMPONENT REQUIRING POWER TO NEXT KEYPAD (** IF REQUIRED) STROBE RELAY MODULE KEYSWITCH ISOLATION MODULE STROBE

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

Fire Alarm System Fundamentals

Fire alarm system specification for multiple tenant retail buildings

Remote NAC Power Supply D7038

June 10, 2002 DF C S2424

IDP-Zone-6 Six Zone Interface Module

July 14, 1999 DF C-100.

XP6-C. Six Circuit Supervised Control Module and SYNC-1 Accessory Card

LifeAlarm Fire Alarm Control Panels

MODEL 5104B. Installation and Operation Manual. Fire Communicator. Part Number E, 09/04

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

TrueAlert Addressable Notification Appliances

Series. Access Power Controllers. Installation Guide

PWGSC Ontario MULTIPLEX FIRE ALARM SYSTEM Sect Region Project Page 1 Number R

TrueAlert Addressable Notification Appliances

LDM Series Lamp Driver Modules For Graphic Annunciation and Control

FireShield Plus. GE Security. EST Life Safety & Communications Conventional Small Building Solutions. Conventional Fire Alarm Control Panels

M O D E L S F I R E G A R D M C V ADVANCE FIRE CONTROL RELEASE DEVICE

Series DV-100 VoiceLink Operation and Installation Manual

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

TrueAlert Non-Addressable, Multi-Candela Notification Appliances Installation Instructions

Concerns: Affects: Dated: June 12, SECTION 1: GENERAL Scope Work Included... 3

Series SPB Audio Boosters Installation, Testing, Operation, and Maintenance Manual

1. Floor above/floor below notification. 2. Private alarm notification. 3. Not Used 4. Voice alarm notification. 5. Not Used.

good things in small packages

Hinesville First United Methodist Church SECTION DIGITAL, ADDRESSABLE FIRE-ALARM SYSTEM

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

MMF Six Zone Interface Module

For a red enclosure add an R suffix to the part # e.g. eflow4na8r. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

ADEMCO 4208SNF V-Plex Universal Class A Module INSTALLATION AND SETUP GUIDE

Remote Booster Power Supply Technical Reference Manual

4100U City and Relay Cards Installation Instructions

DIVISION 26 ELECTRICAL SECTION FIRE ALARM SYSTEM

LiftMaster 300 Windsor Drive Oak Brook, IL LiftMaster.com

E-FSC. Conventional Fire Alarm Control Panels. Standard Features. Overview

EST3 Installation and Service Manual

TrueAlert Multi-Candela Notification Appliances

Installation Guide for models:

Conventional Fire Alarm Systems

1400 Direct Wire Ionization Smoke Detector

FIRE DETECTION SYSTEM SPECIFICATION FOR MODEL XR200

AEGIS FEATURES DESCRIPTION. Conventional Fire Alarm-Suppression Control Unit. Effective: March Programmable Relays

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

Genesis Series Cable THE POWER OF CHOICE. Cables for Silent Knight

Installation Guide for models:

SECTION FIRE ALARM STANDARDS REVISED CONSTRUCTION STANDARD

The TC-4F. Time Control Module C P/N 15972:C ECN For the Sensican 2000 Fire Alarm Control Panel

FireNET Fire Alarm Control Panel Installation Manual

Fort Rouge Leisure Centre Section HVAC Upgrades Phase 2 Page 1 of 5 Bid Opportunity No March 2013 FIRE ALARM SYSTEMS

TECHNICAL DATA OBSOLETE

Installation Instructions Model ABHW-4S

E3 Series Broadband System

FMR Installation Instructions. Addressable Fire System Controller

F220-B6PS/M. Installation Guide. Addressable Detector Bases

SECTION FIRE ALARM SYSTEMS

Genesis LED G1 Series

EST2. Installation and Service Manual P/N REV 07 REB 27FEB13

D7052. Installation Instructions Multiplex Dual Input Module

INSTALLATION AND MAINTENANCE

Versatile. VM Mid-range Life Safety Solutions. S e e. w h a t ' s p o s s i b l e n o w..

Multiplex Eight Input Remote Modules

D7044. Installation Instructions Multiplex Single Input Module

Transcription:

Print Specification Publication GSA-CC1 Single Input Signal Module Installation Sheet P/N P-047550-1802-EN REV 04 ISS 23JUN15 Instructions This page is the print specification for the publication. It is not part of the artwork for the publication and must be removed before production. Do not print this page. Work with the factory manufacturing engineer to determine the best materials and methods to produce, bind, and package the publication. The manufacturing engineer will indicate when single-language editions of a publication should be combined into one print package. Legibility To ensure legibility and usability, we specify the following limits for the final print product: Photoreduction of the artwork must result in a minimum effective font size of 6 pt. for body text. The paper stock and ink used must result in a minimum effective opacity of 85%. Photoreduction and printing methods must result in a minimum resolution of 300 dpi, and all illustration and callout lines must be visible and unbroken. Specific requirements None General requirements The printed publication must meet the following requirements unless otherwise stated in the Specific requirements section. Design and production Artwork is provided as a single-language PDF file of ordered pages at 100% scale. You can photoreduce or imposition artwork page images as needed. When designing the print package, observe the following requirements: Imposition must preserve the intended reading sequence of the pages given in the artwork file. Multiple-language packages must present English first, and the remaining languages in ascending part number order. After folding, the publication part number should be clearly visible without unfolding. No cropping of the artwork is allowed. Information in the headers and footers must be retained. Binding gutters established in the artwork (such as for three-ring binding) must be observed. Color Unless otherwise specified, all printing is in CMYK black. Spot colors and RGB colors found in the artwork should be converted to CMYK black by the print vendor. P/N P-047550-1802-EN REV 04 ISS 23JUN15 1 / 1

GSA-CC1 Single Input Signal Module Installation Sheet Personality codes The module requires the loop controller to download the personality code that determines how the module operates. Use the personality codes described below to configure the GSA-CC1. See Table 1 for listing information. Description The GSA-CC1 Single Input Signal Module is an addressable module that is used to connect the following circuits: Audible and visible notification appliance circuits (synchronized or unsynchronized) Speaker circuits Two-way telephone communication circuits (three-state or four-state) Upon command from the loop controller, the module connects supervised Class B signal or telephone circuits to the respective riser input. The riser input can be 24 VDC (to operate polarized audible and visible signal notification appliances), 25 or 70 VRMS (to operate audio evacuation speakers), or firefighter telephones. The module does not provide signal synchronization. To meet UL 864 requirements for horn and strobe signal synchronization, you must install a Genesis Signal Master module. The GSA-CC1 module requires one address on the signaling line circuit (SLC). Addresses are assigned electronically. There are no address switches. Diagnostic LEDs provide visible indication of the state of the module through the cover plate: Normal: Green LED flashes Alarm/active: Red LED flashes Table 1: Personality code listing information Code Description UL 864 CAN/ULC- S527 5 Signal - supervised output (Class B) 6 Telephone - three-state (Class B) 26 Telephone - four-state (Class B) No No Personality code 5: Signal - supervised output (Class B). Configures the GSA-CC1 module as a riser selector for audible and visible notification appliance circuits or for single-channel audio circuits. The output circuit is monitored for open or shorted wiring. If a short exists, the module will not activate in order to prevent shorting the riser. The module will activate once the short is cleared. Personality code 6: Telephone - three-state (Class B) Configures the module as a riser selector for a three-state firefighter telephone. When a telephone handset is plugged into its jack or lifted from its hook, the module generates its own ring-tone signal, making a separate ring-tone riser unnecessary. The module sends this signal to the control panel to indicate the presence of an off-hook condition, and waits for the system operator to respond to the call. When the system operator responds, the ring-tone signal is disabled. Personality code 26: Telephone - four-state (Class B). Configures the module as a riser selector for a four-state firefighter telephone. Operation is the same as Personality code 6 except that the module can distinguish when a telephone is off-hook and when the circuit is shorted, which causes a trouble condition. 2015 UTC Fire & Security. All rights reserved. 1 / 6 P/N P-047550-1802-EN REV 04 ISS 23JUN15

Installation Notes The module is shipped from the factory as an assembled unit; it contains no user-serviceable parts and should not be disassembled. This module does not operate without electrical power. As fires frequently cause power interruption, discuss further safeguards with the local fire protection specialist. Install in accordance with all applicable local codes and standards and the local authority having jurisdiction. To install the module: 1. Wire in accordance with Wiring below. 2. Write the address assigned to the module on the label provided, and then apply the label to the module. Remove the serial number label from the detector and, and then attach it to the project documentation. 3. Using the screw provided, mount the wall plate on the module. See Figure 1 for mounting details. 4. Using the screws provided, mount the wall plate (with the module attached) on one of the compatible electrical boxes listed in Specifications on page 6. Figure 1: Mounting the GSA-CC1 module (1) (1) Compatible electrical box (2) 2-gang ring cover (if required) (3) Module Protection from transient spikes (4) Wall plate, (dual-gang) #6-32 5/8 screw (4X) #4 1/2 self-tapping screw For installations in which the output circuit connects to electromechanical bells or horns, install a Bipolar Transient Protector (P/N 235196P) to prevent inductive loads from causing transient spikes. To install a bipolar transient protector: 1. Install the transient protector on the output of the module. Fit the transient protector into the electrical box with the module. See Figure 2. (2) (3) (4) Figure 2: Bell circuit showing bipolar transient protector placement 10 9 1. Normal state 2. Active state Wiring Wire in accordance with applicable requirements of the latest editions of the local codes and standards and the local authority having jurisdiction. Strip 1/4 in. (about 6 mm) from the ends of all wires that connect to the terminal block of the module. Note: When stripping wire ends, exposing more wire may cause a ground fault; exposing less wire may result in a faulty connection. General wiring notes Refer to the Signature loop controller installation sheet for SLC wiring specifications. Refer to the firefighter phone installation sheet for additional details. Each terminal on the module is limited to a single conductor. Test resistors are supplied with the GSA-CC1 to prevent trouble signals on unused circuits during installation. When connecting field wires, remove the test resistors and install a UL/ULC Listed 47 kω EOLR at the end of the circuit. The module does not support conventional smoke detectors. Riser notes (1) (2) For maximum line impedance, refer to the installation manual for the fire alarm panel. Maximum circuit capacitance is 0.1 µf. If the riser is used for more than one notification zone, install in accordance with the survivability from attack by fire requirements in NFPA 72 National Fire Alarm and Signaling Code. Circuit and riser wiring is different when four-state firefighter telephones are installed on three-state circuits. Before replacing a GSA-CC1 module, tag the wires to ensure correct reconnection. The GSA-CC1 module does not supervise the riser; the fire alarm control panel provides this function. 2 / 6 P/N P-047550-1802-EN REV 04 ISS 23JUN15

To wire the module: 1. Verify that all field wiring is free of opens, shorts, and ground faults. 2. Make all the connections as shown in Figure 3 through Figure 5. Figure 3: Wiring diagram for NAC (personality code 5) (1)(2)(3)(4) (3)(8) (1) Signal polarity is shown when the circuit is in supervisory state. Polarity reverses when the circuit is active. (2) Supervised. (3) Power-limited unless connected to a nonpower-limited source. If the source is nonpower-limited, eliminate the power-limited mark and maintain a minimum of 0.25 in. (6.4 mm) space from power-limited wiring. For other mounting methods, see enclosure and bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring. The wire size must be capable of handling fault current from nonpower-limited source. or Use type FPL, FPLR, FPLP, or permitted substitute cables, provided these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in. (6.4 mm) space or by a nonconductive sleeve or nonconductive barrier from all other conductors. Refer to the NFPA 70 National Electrical Code for more details. (4) If using a G1-P Genesis series horn while connected to a compatible fire alarm control panel, a CDR-3 Bell Coder must be used to comply with ANSI S3.41. 47 kω EOLR. Signaling line circuit (SLC) to next device. AUX riser (to next module or riser supervisory device). (8) Power-limited regulated, power supply UL/ULC Listed for fire protective signaling systems. AUX riser (from previous device). Signaling line circuit (SLC) from previous device. Supervised and power-limited. P/N P-047550-1802-EN REV 04 ISS 23JUN15 3 / 6

Figure 4: Wiring diagram for audio (personality code 5) (1)(2)(3)(4) (1) Signal polarity shown when the circuit is in supervisory state. Polarity reverses when the circuit is active. (2) Supervised. (3) Power-limited unless connected to a nonpower-limited source. If the source is nonpower-limited, eliminate the power-limited mark and maintain a minimum of 0.25 in. (6.4 mm) space from power-limited wiring. For other mounting methods, see enclosure and bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring. The wire size must be capable of handling fault current from nonpower-limited source. or Use type FPL, FPLR, FPLP, or permitted substitute cables, provided these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in. (6.4 mm) space or by a nonconductive sleeve or nonconductive barrier from all other conductors. Refer to the NFPA 70 National Electrical Code for more details. (4) Unshielded twisted pair. 47 kω EOLR (P/N EOL-47). Signaling line circuit (SLC) to next device. Audio riser (to next module or supervisory end of line device). (8) Unshielded twisted pair. Use shielded twisted pair when installed in the same conduit as with a telephone riser. Audio riser (from previous device). Signaling line circuit (SLC) from previous device. Supervised and power-limited. 4 / 6 P/N P-047550-1802-EN REV 04 ISS 23JUN15

Figure 5: Class B telephone (personality codes 6 and 26) Three-state telephone circuit (personality code 6) (1) Telephone circuit. The plus and minus symbols indicate signal polarity. (1)(2)(3) (4) (2) Supervised. (3) Power-limited unless connected to a nonpower-limited source. If the source is nonpower-limited, eliminate the power-limited mark and maintain a minimum of 0.25 in. (6.4 mm) space from power-limited wiring. For other mounting methods, see enclosure and bracket installation sheets to maintain separation of power-limited and nonpower-limited wiring. The wire size must be capable of handling fault current from nonpower-limited source. or Use type FPL, FPLR, FPLP, or permitted substitute cables, provided these power-limited cable conductors extending beyond the jacket are separated by a minimum of 0.25 in. (6.4 mm) space or by a nonconductive sleeve or nonconductive barrier from all other conductors. Refer to the NFPA 70 National Electrical Code for more details. (3)(8) (4) Required if the distance from the GSA-CC1 to the phone is greater than 5 ft. Shield must be continuous, insulated, and isolated from ground, except for the connection to chassis ground in the control panel. 47 kω EOLR (P/N EOL-47). Four-state telephone circuit (personality code 26) (1)(2)(3) (4) Signaling line circuit (SLC) to next device. Telephone riser (to next module or end-of-line supervisory device). (8) Use shielded twisted pair. Shields must be continuous and grounded at the panel end. Telephone riser (from previous device). Signaling line circuit (SLC) from previous device. Supervised and power-limited. (3)(8) P/N P-047550-1802-EN REV 04 ISS 23JUN15 5 / 6

Specifications Operating voltage range Current Standby Activated Maximum line impedance Ground fault impedance Output ratings (special applications) 24 VDC 25 VRMS audio 70 VRMS audio EOL resistor value Circuit resistance EOLR Circuit capacitance Circuit designation Signaling line circuits Telephone riser circuits Notification line circuits Compatible electrical boxes Wire sizes Operating environment Temperature Relative humidity Storage temperature range 15.20 to 19.95 VDC 310 µa 135 µa Refer to the control panel installation manual 10 kω 2 A 50 W 35 W 47 kω Refer to the control panel installation manual 0.1 µf max. 47 kω (P/N EOL-47) Class A, Style 6 or Class B, Style 4 Class B, Style 4 Class B, Style Y 2-1/2 in. (64 mm) deep dual-gang box; 4 in. square box 1-1/2 in. (38 mm) deep box with a dual-gang cover 12 to 18 AWG wire (0.75 to 2.5 mm²) 32 to 120 F (0 to 49 C) 0 to 93%, noncondensing 4 to 140 F ( 20 to 60 C) Regulatory information Manufacturer Year of manufacture FCC compliance North American standards Contact information Edwards, A Division of UTC Fire & Security Americas Corporation, Inc. 8985 Town Center Parkway, Bradenton, FL 34202, USA The first two digits of the DATE MFG number (located on the product identification label) are the year of manufacture. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CAN/ULC-S527, UL 864 For contact information, see www.utcfireandsecurity.com. 6 / 6 P/N P-047550-1802-EN REV 04 ISS 23JUN15