C1N & C2N SERIES Fluid heating for light industrial applications

Similar documents
HL SERIES Fluid heating for commercial applications

CLE SERIES Fluid heating for emergency eyewash stations

C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable C2N Series - Light Industrial Heaters Tankless Water Heating Solutions

CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Portable C1N Series - Light Industrial Heaters Tankless Water Heating Solutions

Portable CNA-Series - Large Industrial Heaters Tankless Water Heating Solutions

Discontinued. SN Series - Safety Shower Heaters Tankless Water Heating Solutions. Standard Equipment. Construction. Code Compliance and Certifications

Keltech SNA-Series - Safety Shower Heaters Tankless Water Heating Solutions

SNA-SKID Series - Preassembled Safety Shower Heater Skid Tankless Water Heating Solutions

S19361F - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

KELTECH ELECTRIC TANKLESS WATER HEATERS. Fluid heating for commercial, industrial and safety applications PRECISE. RELIABLE. DURABLE. TANKLESS.

S19361HF - Pre-Assembled Freeze-Protected Safety Shower Heater Skid Tankless Water Heating Safety Solutions

SN Series - Safety Shower Heaters Tankless Water Heating Solutions

Installation Keltech C2N Series Tankless Heater Models

Circulating Water Temperature Controller

Circulation Heaters Selection Guidelines

Circulation Heaters Selection Guidelines

Industrial Solutions. Plumbing Fixtures, Safety Fixtures & Locker Rooms BRADLEYCORP.COM

Tankless Electric Water Heater Available up to 54 KW in Single or Three Phase Voltages

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

Installation. Keltech S194 Series. Tankless Water Heating Solutions. Table of Contents

WATLOW IND. WATROD Circulation Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Tankless On Demand Electric Water Heater

ULTRA-SAFE Explosion-proof Duct Heaters

OPERATING AND MAINTENANCE MANUAL FOR PLATE HEAT EXCHANGER INDIRECT FIRED WATER HEATER. Electric Heater Company Base Model "BWXP"

SECTION PLUMBING EQUIPMENT

C D E F. Tubular Industrial Process Circulation Heaters. Circulation Heaters. View Product

Models 1005, 1505, 2005 Up to 99% thermal efficiency!

EB-M*-** Midsize Electro-Boiler BL509. EB-S-**/EB-WX-**-2 TS Standard Electro-Boiler BL506. EB-CX-** TS Commercial Electro-Boiler BL508

WATLOW IND. WATROD Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2.00

SAFETY PLUMBING PACKAGES. Quality Products & Value Packages SUSTAINABILITY. Residential Solutions ANTI-SCALE SYSTEMS FIRE PROTECTION

"ESDDR" Series Electric Humidifier

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Chromalox Calderas eléctricas tipo paquete, de agua caliente, calderas de vapor, son fuente de calor

ULTRA-SAFE Explosion-proof Duct Heaters

Tankless Electric Water Heater Available 3-27 kw in Single Phase Voltages

HHA Bellerive Apartments 7225 Bellerive Houston, Texas J. Allen Management Managing Agent

Packaged Instantaneous Circulation Heater Full KW Selection In All Voltages, Single or Three Phase

Electronic Flow Switches

UNIVERSAL SOLVENT HEATER

Models 1005, 1505, Up to 99% thermal efficiency! Can be vented with PVC pipe Use Option D-32

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

University of Houston Master Construction Specifications Insert Project Name SECTION DOMESTIC WATER HEATERS PART 1 - GENERAL

WATLOW IND. FIREBAR Flange Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 6/11/2008 Rev: 2.00

Tubular Industrial Process

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

COMPASS HIGH-EFFICIENCY WET-ROTOR CIRCULATORS

Circulation Heaters. To order, call or shop online at omega.com SM. CHF Series

CAST-X Circulation Heater. With optional built-in controls, CAST-X 1000 is a straightforward solution, perfect for OEMs and end users.

SEISCO SUPERCHARGER EXTENDER/BOOSTER INSTALLATION GUIDE & OWNERS MANUAL

ASME Packaged Electric Water Heater

The Finest Tankless Electric Water Heaters Available! Commercial Application Point-of-Use Tankless Electric

TABLE 1. Specifications: Dimensions: 6¼ x 9 5/8 x 2 ¾

INSTANT-FLOW C-MICRO WATER HEATER

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

Complete packaged and custom solutions for mechanical, plumbing, and industrial systems.

Differences Among Screw Plug Immersion Heaters

LTFX Electric Tank Immersion Heaters Installation Instructions

RQE Series Temperature Controllers

Control and power circuit fusing to meet N.E.C.

PROVIDES TEPID WATER FOR EMERGENCY SHOWER

HHA Lyerly Apartments 75 Lyerly Houston, Texas J. Allen Management Managing Agent

Dual Tower Heat Reactivated Desiccant Air Dryer

! The Caution Symbol (exclamation point) alerts you to a "CAUTION", a safety or

Multiple Heater Controller TempTracker Mod+, up to 16 heaters

Your Single. Source. Partner with Watts Water. for a Comprehensive Suite. of Innovative Water Solutions. OneWattsWater.com

FX5 Series Explosion-Proof Electric Air Heaters

Your Single Source Partner with Watts for a Comprehensive Suite of Innovative Water Solutions

ECONOMICAL, EFFICIENT PERFORMANCE

Distributed By: M&M Control Service, Inc Building Technologies

Page. 1-2 Sepra-Lite Integral Optic Level Switches. 3-5 Electro Optic Level Systems: Probe and Controller

INSTANT-FLOW C-MICRO WATER HEATER

HR Heated HB Blower. Smart Solutions for Drying Compressed Air. Dual Tower Heat Reactivated Desiccant Air Dryer

Direct Gas-Fired Make-Up Air

WATLOW IND. WATROD Modular Duct Heater Installation & Maintenance Manual I&M NUMBER: Page: 1 Date:6/11/2008 Rev: 2

INSTALLATION & MAINTENANCE MANUAL FOR QuickDraw

INSTALLATION INSTRUCTIONS AND OWNER S MANUAL FOR

Revitalize Building Mechanical Systems (4619)

CONDENSING HIGH EFFICIENCY BOILERS

Triton Series High Efficiency Boiler

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

PURGE/PRESSURIZATION SYSTEM

EHB Series. STONESTEEL Commercial Electric Water Heaters Individually Mounted Elements Vertical or Horizontal CEMLINE CORPORATION

2012 Catalog Version AUG 2012 Noritz America Corporation. All rights reserved.

Tempra / DHC-E. Simply the Best. The Finest Tankless Electric Water Heater Available! Featuring Advanced Microprocessor Control ENGINEERING EXCELLENCE

TECHNICAL. Series 18. Pump Packages

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

ProRadiant Controls, Valves and Actuators

Tepid Water Delivery System

Shop Online Eccotemp.com/products. Store Locator Eccotemp.com/locator. Product Support support.eccotemp.com.

Tubular Industrial Process

WATLOW ELECTRIC MFG CO. FIREBAR Screw Plug Installation & Maintenance Manual I&M NUMBER: Page: 1 Date: 11/25/2013 Rev: 4.

Indirect Gas-Fired Make-Up Air

Screw Plug Immersion Heaters

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

Immersion Heaters. Screw Plug Immersion Heater

Transcription:

Keltech Electric Tankless Water Heaters C1N & CN SERIES Fluid heating for light industrial applications Contents Keltech Electric Tankless Water Heaters C1N & CN Series Overview Standard Features 6 Optional Features PRECISE. RELIABLE. DURABLE. TANKLESS. BRADLEYCORP.COM

KELTECH ELECTRIC TANKLESS WATER HEATERS C1N & CN SERIES LIGHT INDUSTRIAL APPLICATIONS Efficient. Precise. Fast. Keltech is the recognized leader in commercial electric tankless water heating systems. Whether your application is industrial, hotels, stadiums, food processing, or safety, there is a Keltech tankless water heating solution. With unmatched quality and durability, Keltech manufactures the fastest, most reliable, and most efficient tankless water heaters in the industry. Keltech tankless heaters are offered in a full line of products for an extensive range of applications as well as custom designs for unique environments. Keltech tankless water heaters have been on the market for over 5 years and are now an integral part of Bradley Corporation's water heating solutions. For 95 years, Bradley has manufactured commercial safety, water tempering, and washroom products. Today, Bradley is the industry's most comprehensive source of commercial and industrial plumbing fixtures, tankless water heaters, washroom accessories, partitions, emergency fixtures, and plastic lockers. Save Energy Inefficient boiler systems have to generate heat and maintain temperature hours per day, 7 days per week. Keltech tankless heaters only heat water when needed. And, Keltech's innovative controller is fully modulating so you only use the actual kw needed, not full power or stages. Save Space A large commercial tank water heater requires a large space. Keltech tankless water heaters only require square feet (0. square meters) of space to generate up to 91,000 BTUs. Simple Installation Requires only one electrical connection and water. No pumps, no external fusing, and no design needs to be considered externally it's all built into the heater. Simple to Maintain No tank to maintain, no anodes, no softeners. Simply the Best Built to the toughest standards with the highest quality materials and engineered to meet the world's most demanding applications.

C1N & CN Series The C1N & CN Series are designed to accommodate light industrial fluid heating applications where demand is between 18 and 50 kw and total flow is 15 GPM (56.8 L-Min). The heaters activate only when needed and provide an unlimited supply of hot water to meet the needs of your light industrial application. Heaters activate at 0.75 GPM (.8 L-Min) with low flow options available, depending on the heater. Key markets & applications Markets include pharmaceuticals, food and beverage, waste water treatment plants, municipal buildings, manufacturing, zoos, lodging, transportation and marine. Applications include chemical process heating direct/indirect, laundry, train & truck washing, heating deionized water, potable water distribution, snow melt, classified areas, heating consumables requiring FDA approval, recirculation, reverse osmosis pre- and post-heating, heating jacketed equipment and washdown (parts, clean room, sensitive materials, manufacturing). Whatever your specific application is, Keltech has a tankless heating solution. kw Range C1N: 18-5 kw CN: 6-50 kw Code Compliance & Certifications Flow Range 0.75-15 GPM (.8-56.8 L-Min) Standard Voltages 80V, 600V -Phase Delta Lead-Free Brass/Copper heat exchangers certified to NSF/ANSI 7 Third-Party Certified ETL listed to UL99, UL50E, NFPA 96 (for hazardous locations) C-ETL listed to CSA-C. No.88. Compliant to NEC/NFPA 70 and Canadian Electrical Code C.1

C1N & CN SERIES STANDARD FEATURES STANDARD FEATURES PID Temperature Controller More energy efficient and reliable than traditional microprocessors, Keltech heaters hold temperature as demand changes regardless of incoming ground water temperature. Power is infinitely variable, with no fixed inputs. The PID controller makes it possible to modulate the amount of power applied to the elements while also dispersing the required power evenly across all elements. This unique feature increases the product s life cycle. Simple Touch Operation Digital LED screen with touch pad for easy operation shows set point & output temperature. Precise Temperature Range & Flow The electronic power modulation system can control outlet water temperature to within +/- 1 F (+/-0.56 C) over a wide range of flow rates. Precision temperature controls make Keltech tankless water heaters the preferred choice for process heating applications or an alternative to high energy consuming boiler use. Incoloy 800 Elements Extends the life of the metal components. Provides protection, durability and resistance to scaling from hard water. Water is only heated when flowing; sediment will not collect in the heat exchanger. Low Watt Density Element Extremely low wattage is applied per square inch of the element for improved heat transfer & reduced scaling which results in a longer lasting element. Electrical Design Requires only one service feed per unit. Includes internal fusing as standard, which provides superior protection. Units have a delta wiring system and do not require a neutral. Auto Reset High Limit Switch Internal circuit breakers monitor for over temperature conditions and ensure individual chambers do not exceed standards. Should the heater s safety circuits sense a problem prior to manual shut down, power is safely interrupted at a mechanical relay. Solid State Relays C1N Series feature liquid-cooled, solid state relays to provide silent switching which has a faster response than mechanical relays to help maintain an accurate temperature. Relay switching controls also provide an infinitely variable power draw. The CN Series feature fan-cooled relays (above), ideal for high temperature recirculation loops. Independent & Redundant Safeties Keltech light industrial heaters include multiple features that ensure years of reliable service and the safety of your employees Bi-metal Manual Resets Every heater that Keltech engineers includes a separate set of circuits that monitor over temperature conditions. Should overheating occur, each sector of the heat exchanger has a dedicated thermal switch that breaks power. Normal operation cannot be resumed until the safety switch is manually reset.

C1N & CN SERIES STANDARD FEATURES STANDARD FEATURES NEMA Enclosures Standard wall cabinet enclosure is NEMA rated amd constructed of 16 gauge steel with corrosion-resistant paint. Enclosure protects components from dust and water. Minimal Pressure Drop Keltech's best in industry low pressure drop reduces or eliminates the need and expense associated with adding pressure booster pumps. Durable Plumbing Assembly All units consist of brazed joints, a brass and copper heat exchanger, industrial-grade flow switch and brass castings/fittings at all directional changes. Premium Materials All waterways consist of high-quality copper and brass construction tested to 00 PSI (0.7 bar). Robust lead-free brass castings & flanges are CNC cut from solid brass blanks for precision fit. High-quality copper & brass construction extend the life of the heat exchanger. Recirculation Capable Keltech heaters can be installed within a recirculation system, saving money & energy while providing desired temperature on demand. Activation Requirements On-demand heaters require a minimum flow rate for activation. Water heaters come standard with 0.75 GPM (.8 L-Min) activation set point & can provide flow up to 15 GPM (56.8 L-Min). Minimum flow requirements provide maximum efficiency. Reliable Performance & Minimal Maintenance The heater maintenance schedule falls within the normal facilities maintenance program requirements. LED indicators, test buttons, and reset buttons on the front cover dramatically reduce the need to open the enclosure making maintenance or troubleshooting even easier. Easy to Install Heaters can be wall- or floor-mounted almost anywhere. Without a traditional tank the C1N & CN Series save space in any installation location. C1N Interior CN Interior BIM-REVIT MODELS AVAILABLE FOR ALL KELTECH SERIES @BRADLEYCORP.COM 5

C1N & CN SERIES OPTIONAL FEATURES NEMA X Enclosures For harsh environments, NEMA X watertight enclosures are available for an additional level of protection. Enclosures are made from 0 or 16 stainless steel. Building Management Systems Integration Transfers control of the heater to a Building Management System (BMS). Heater is no longer adjusted or controlled at the heater location, a computer interface integrates with the BMS. Low Flow Activation Activate heater at a lower flow rate than the standard 0.75 GPM (.8 L-Min). C1N activation available as low as 0.5 GPM (1.0 L-Min) and CN, 0.5 GPM (1.9 L-Min). Integral Ground Fault Detects electrical leakage from external sources and protects the equipment, electronics and heat exchanger by terminating power to the elements and disabling operation of the unit. High Temperature Package Standard temperature range is 0-160 F (-71 C). With the high temperature package, heaters can reach and maintain settings as high as 160-190 F (71-88 C). Internal Fused Disconnect The internal fused disconnect interlocks with the enclosure door when energized, prohibiting access to a live cabinet. There is no need to install an external disconnect. TE and TE Protection System: Deionized Water Solutions & Corrosive Fluid Protection Exclusive TE and TE Protection options protect the heat exchanger from corrosive fluids including deionized water, chlorides, saltwater solutions, reverse osmosis water and caustic alkalis. Keltech uses bright annealed, passivated stainless steel elements; all stainless steel plugs and fittings are also used. TE Protection is recommended when corrosion is a concern. It is FDA approved for use with deionized water or mild corrosive fluid applications. The PFA Teflon dual coating protects all heat exchanger surfaces that come in contact with heated fluids. TE Protection is recommended when fluid purity is critical (e.g. to heat de-ionized water). To conform to FDA regulations governing direct food contact applications, this option includes a single layer of Xylan Fluoropolymeric coating on all surfaces and internal passageways that come in contact with the heated media. Choose the TE or TE protective coating for: Media Purity: no contamination of heated fluids. Non-stick: very low adhesion properties for best possible flow characteristics Virtually inert: resists change or destruction due to chemicals or corrosion Thermal Stability: resists change due to temperature fluctuations Washing solid-state devices, printed circuit boards, parts & aluminum products and/or equipment Heating corrosive and/or non-flammable liquids Desalination systems Design on Demand Custom Solutions C1N & CN Series heaters are engineered for durability and performance in any light industrial application. And, when unique environments require innovative solutions, Bradley Engineers design custom systems for any heating need: When recirculation or a booster heater is needed, Keltech fullymodulating liquid-cooled heaters are the perfect solution. Custom solutions available for your unique application requirements. When the run is too long or pressure is too low, Keltech booster systems are pre-piped and ready to be installed in Series or in parallel. Work directly with a Keltech System Design Consultant. 6

R 1 5 1 5 C1N & CN SERIES OPTIONAL FEATURES Explosion-Proof Purge System C1N & CN Series light industrial heaters in NEMA /X enclosures can be equipped with an explosion-proof purge system. The type of purge system determines the classification or division the enclosure will meet; C1N & CN Series use a system that conforms to Class 1, Division hazardous area standards. Electrical components installed in NEMA /X enclosures allow the system to be pressurized by clean instrument air or inert gas. Heat, moisture, dust and corrosion are eliminated by providing the enclosure with a slow but continuous flow of inert gas or dry compressed air. This process removes flammable gases and/or prevents the accumulation of ignitable dusts within the protected enclosure. The purge system: Conforms to Class 1, Division hazardous area standards; other class and division ratings may be available Reduces heat build-up in the enclosure Inhibits metal corrosion and reduces moisture buildup Provides continuous monitoring capabilities Eliminates large, heavy explosion-proof enclosures A constant supply of inert gas or clean air required C1N Series CN Series Purge System Relief Valve Purge System Relief Valve Conduit Hub Class 1 Div. supplied by others Conduit Hub Class 1 Div. supplied by others 1 5" (17mm) 1 5" (17mm) Explosion-proof sealing fitting supplied by others 18" (58mm) Max 18" (58mm) Max Explosion proof sealing fitting supplied by others 1 Suggested region for power entrance. Entrance hole and components to be provided by installer. Purge control panel Class 1 Division. Purge gas/compressed air inlet fitting here. Spark arrestor with calibration orifice is located in the bottom of the enclosure. All installation egress from panel must be sealed (electrical conduit) for proper explosion-proof installation. 7

BIM-REVIT models available on bradleycorp.com PRECISE. RELIABLE. DURABLE. TANKLESS. +1 6 51 6000 800 BRADLEY bradleycorp.com W1 N9101 Fountain Boulevard Menomonee Falls, WI 5051 USA 07-0116