Accessories. Desk Top Controls

Similar documents
Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

Egress Devices for Code Compliant Access-Controlled Egress Doors

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Code Compliance. Selected Exit Check models are available to comply with one or more codes listed below. See Operation on page 3.

Multi-Mode Annunciators

Optional cable and connectors SELECTRIC TM PRO

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

PoE SOLUTIONS Power over Ethernet Capable Locking Hardware SOLUTIONS

Exit Check Integrated Delayed Egress Locks

Exit Check Integrated Delayed Egress Locks

EXIT CHECK DELAYED EGRESS LOCKS

QUIET DUO LR100 SERIES

Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Exit Check Integrated Delayed Egress Locks

ACCESS & EGRESS REMOTE CONTROLS SOLUTIONS. The lock behind the system. SDCSecurity.com

POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

Innovative Access & Egress Solutions. Security Door Controls Condensed Catalog. Copyright 2014, Security Door Controls. US Made

Delayed Egress System DORMA EMDE

631RF Amp Power Supply

UNIVERSITY OF ROCHESTER DESIGN STANDARDS FEBRUARY 2005MARCH 2007

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Security Professional Mobile Showroom. Product Training

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

LR100 24V Latch Retraction / Dogging Kit

LR100 24V Latch Retraction / Dogging Kit

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

ABLOY EFEND. New name for security

POWER SOURCES MODEL NO. DESCRIPTION PRICE

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

Is the Key! Premium Grade Access Control Hardware

SECTION DOOR HARDWARE

Delayed Egress Locks 38 SECURITY DOOR CONTROLS

White Papers: Delayed Egress Hardware

Series Electric Hinges/Pivots Hager Ives McKinney Stanley PBB Bommer Rixson ABH and more

ACCESS & EGRESS LOCKING DEVICES SOLUTIONS. 1.2 Delayed Egress Locks. The lock behind the system. SDCSecurity.com

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

STANDARD FEATURES SPECIFICATIONS

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

APPENDIX F: LOCKSETS AND ACCESS CONTROL

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

Digital & Card Access Control Systems

Pilfergard Door Alarms

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

Mechanical to Electrical Making the Jump

Complete Component Considerations

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

1. Items known commercially as finish hardware or builders hardware, required for swing, sliding, or folding doors.

Architect s Specification Guideline:

STANLEY PATIENT SAFETY LEVER (SPSL) STANLEY SECLUSION ROOM LOCK (SSRL) STANLEY EMERGENCY DOOR ALARM (SEDA)

PRODUCT INTRODUCTION

about HES is ISO 9001:2000 certified.

PRICELIST Access. Value. Today.

2409/2900. Fire Guard

Remote Chexit Module (RCM) System. General Information

Upgrade Your Solution: Mechanical to Electrical

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

Mechanical to Electrical Solutions. for Aluminum and Glass Openings

INSTALLATION INSTRUCTIONS EXIT CHECK DELAYED EGRESS EMLOCK 1511S / 1511T

2408/2900. Fire Guard

System Design and Overview Document

ED4000. Narrow Stile Pushpad Exit Devices

GATE & Fence. Solar Power Supplies. Gate Locks. Gate Lock Bracket Kits. Specialty Brackets. Power Supplies. And More...

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

Alarmed Exit Hardware

DE5300 Delayed Egress System. General Information

SARGENT Beacon TM. A Technical and Informational Newsletter From Dugmore & Duncan. Summer 2009 Vol. VIII - Issue II L

Electromechanical Locks & Exit Devices

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

HES and Securiton have united as ASSA ABLOY Electronic Security Hardware. Electronic Security

EntryCheck E70 Series

ALARMED EXIT HARDWARE

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

INSTALLATION INSTRUCTIONS EA SERIES DOOR PROP/EXIT ALARM

BEA, Inc. Microwave Detector. Infrared Detectors. Time Delays/Security Modules. Accessories

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Installation Instructions

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

Series 98/99. All Series 98/99 are available with antimicrobial coating. (Page 38 for more detail) OPTIONS AND ACCESSORIES. Touchbar Exit Devices

5900 Series X-in Low Energy Power Operator

5900 SERIES Low Energy Power Operator

Modular Fillerplate Subassembly P/N: X Endcap P/N: Strike *, P/N: " Narrow Stile Plastic Template. Mortise.

UBC Technical Guidelines Section Edition Access Control Page 1 of 5

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

AO19 SERIES LOW ENERGY AUTOMATIC DOOR OPERATORS

Electric Dogging (ED)

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

CM800 Emergency Call System

SECTION INTRUSION DETECTION

SECTION DOOR HARDWARE

Hardwired Alarm Accessories

Single Door 39.5 Right Hand Push AL. Double Door (Twin) 75.5 Push AL Simultaneous 92 Push 11 + reveal BZ Independent Max reveal on a pull 2.

Transcription:

Accessories Desk Top Controls 15-2 15-1 15-3 15-2-3 DTMO-1 DTMA-1 Under Desk Top Mounting The SDC 15 series switch controls are mounted on the underside of a desk for remote door control. They may be connected to the REX input of an access control or to the trigger input of a time delay relay to allow timed access and egress. The 15-2-3 is equipped with one momentary switch to provide momentary access and a toggle switch for sustained bypass. 15-1 On-off push switch, 6 Amp 15-2 Momentary push switch, 10 Amp 15-3 On-off toggle switch, 6 Amp 15-2-3 On-off toggle switch and momentary push switch, 6 Amp Contact: SPDT, 6 Amps @ 30VDC Dimensions: 15-2 1"H x 2.25"W x 2.5"D (25.4 x 57.2 x 63.5mm) 15-1 / 15-3 / 15-2-3 1.125"H x 3.125"W x 1.5"D (28.6 x 79.4 x 38.1mm) Mini Desk Top Console The SDC DT series consoles have a clean look for desktop applications. The heavy duty momentary push switches may be connected to the REX input of an access control or trigger input of a time delay relay. The maintained switch station may be wired to provide sustained bypass (unlock). When connected to a door status switch (DPS) or magnetic bond sensor (BAS), the bi-color LED can provide status indication of the door and/or locking device. DTMO-1 One Momentary station and one LED DTMO-2 Two Momentary stations and two LEDs DTMA-2 Two Maintained stations and two LEDs DTMOMA-2 One Momentary station and 1 maintained station and two LEDs Contact: SPDT, 5 Amps @ 30VDC Dimensions: 4.125 W x 3.125"H x 6.25"D (79.4 x 104.8 x 158.8mm) LED: One, tri-color LED. Illuminates red, or green or amber Finish: Gloss Beige Material: 0.0936" (2.286mm) aluminum Power: 24VDC @ 0.02 Amp required for each LED DTMO-2 DTMA-2 DTMOMA-2 Emergency Door Release The SDC 490 Series Emergency Door Release is ideal for immediate unlocking of doors that are equipped with failsafe electric locks and may influence approval of an electric lock system. The built in alarm may be used as a local door annunciator. 491 Features: Alarm 2-SPDT 10 Amp contacts Remote monitoring CCTV activation, or alarm activation Single gang box mounted Two replacement glass plates included 492 Features: Alarm 2-SPDT 10 Amp contacts Blue housing with easy read activation instructions Release of one or all doors on same circuit Single gang box mounted 491 CSFM 3625-0324-107 492 491 Break glass emergency door release 3V-28VDC, 18mA with siren (blue) 491-GL4 Four replacement glass plates 491-BB Surface mount back box (blue) 492 Pull station emergency door release 3V-28VDC, 18mA with siren (blue) 492-GL4 Four replacement glass rods 492-BB Surface mount back box (blue) SECURITY DOOR CONTROLS www.sdcsecurity.com Email: service@sdcsecurity.com ISO 9001 : 2000 FM 52705

Power Transfer Devices PT-5 18" (447mm) stainless steel armored flex conduit with small plastic end caps or termination box. Recommended for use with hollow metal and aluminum frames. PT-2U With black end caps PT-3V With aluminum wire termination box PT-2U PT-5 Concealed Mortise Mount Power Transfer Loop Frame mortised steel dust box with flexible steel loop and chrome finish. Recommended for use with hollow metal frames. UL Listed Dimensions: 11.5"H x 1"W x 0.75"D (292 x 25.4 x 19mm) PT-3V Electric Power Transfer Hinges Features 4.5' Ft Cable UL10B Listed for 3 Hour Fire Rated Doors. Wire Replacement Warranty Power Transfer Hinge Application Installed in the center hinge position of the door, PTH Power Transfer Hinges provide the concealed wires required to transfer power from the frame to electric hardware in the door for control and monitoring capability. PTH 10B Listed For 3 Hrs Fire Rated Doors PTH-4Q PTH-4Q-DPS PTH-10Q PTH-10Q-DPS Four (4) Conductor Power Transfer Hinge Four (4) Conductor Power Transfer Hinge with Door Status Contact Door Status Contact: 250 ma @ 30VDC Ten (10) Conductor Power Transfer Hinge Ten (10) Conductor Power Transfer Hinge with Door Status Contact Door Status Contact: 250 ma @ 30VDC FOR VON DUPRIN EL 33 AND 99 SERIES EXIT DEVICES AND OTHER HIGH INRUSH DEVICES The PTH-2-4 hinges have been tested with Von Duprin* EL devices and Von Duprin power booster at Underwriters Laboratories. PTH-2-4Q 16 Amp Inrush, 6 conductor power transfer hinge 1-pair 16 Amp inrush, 4 Amp continuous; 2-pair 1 Amp @ 12/24V PTH-2-4QDPS 16 Amp Inrush, 6 conductor power transfer hinge, with door status contact 1-pair 16 Amp inrush, 4 Amp continuous; 2-pair 1 Amp @ 12/24V Concealed Door Position Contact, 250 ma @ 30VDC

400U-L2 400U-LT2 400-SN 400-RMB Audible and Visual Annunciators Stainless steel single gang or narrow frame mount annunciator assemblies. Dual voltage 12/24VDC. 400U-L2 One red and one green LED, 1 gang 400NU-RMB Buzzer, narrow 1.75 " wide, specify 12VDC or 24VDC 400U-LT1 One tri-color LED, illuminates red, green and yellow, 1 gang 400U-LT2 Two tri-color LED s, illuminates red, green and yellow, 1 gang 400U-RMB Buzzer, 1 gang, specify 12VDC or 24VDC 400NU-SN 400NU-SN 85 db siren, 1 gang 3-8VDC, 18mA 85 db siren, narrow 1.75 " wide 3-28VDC, 18mA CB401-AU CB402-AU CB401-B CB402-B Communicating Bathroom Systems Controls For a common single bathroom shared by two patient rooms or dormitory rooms, the CB400A controls provides privacy and ensures that both doors are locked only when the bathroom is occupied and unlocked when the bathroom is not occupied. The CB400B controls provide emergency access by facility staff. Both doors unlock when signalled by the fire life safety system. For communicating bathroom systems with EMLocks CB401-AU The CB401-AU is located inside the bathroom. Depressing the button locks both doors for privacy. Pressing the button again unlocks both doors ensuring both doors are unlocked when unoccupied. CB401-B The CB401-B emergency door release (2 required) is located outside the bathroom above or adjacent to the door. The illuminated push switch lens indicates the doors are locked. Depressing the push switch unlocks both doors. Additional system requirements: Two SDC EMLocks 1581-DPS 650lbs holding force or 1571-DPS 1200lbs holding force; 631RF CR access control power supply with fire alarm release input. For communicating bathroom systems with Hi/Tower electrified locksets CB402-AU The CB402-A is located inside the bathroom. Depressing the push switch locks both doors on the outside only. Doors are always unlocked on the inside for uninhibited egress. Exiting either door causes both doors to unlock. CB402-B CB402-B emergency door release (2 required) is located outside the bathroom above or adjacent to the door. The illuminated push switch lens indicates the doors are locked. Depressing the push switch unlocks both doors. Additional system requirements: Two SDC HiTower locksets Z7250-REX or Z7850-DS ; 631RF LR access control power supply with fire alarm release input. Power transfer hinge loop required with Z7850-DS and Z7250-REX. Timers 10TD 14-2 10TD Mini Timer The SDC 10TD is a field adjustable 1-60 second miniature time delay relay designed for timed unlocking of electric locks. The 10TD Mini Timer is small enough to fit in a single gang box or inside the door frame. Contact: SPDT dry, 2 Amps @ 30VDC Voltage: 12/24V AC/DC @ 50mA Trigger Input: N.O. (normally open) Dimensions: 2.25"H x 1.5"W x 0.75"D (57.2 x 38.1 x 19.1mm) 14-2 Seven Day, Skip-A-Day Timer The SDC 14-2 is a compact, field programmable, 7 day skip-a-day timer module recommended for automatic timed locking and unlocking of one door or all doors on the same circuit. The timer may be programmed to skip unlocking on selected days or weekends. The timer may also be installed in a power supply Contact: SPDT dry, 16 Amps @ 30VDC Voltage: 12V AC/DC or 24V AC/DC please specify Dimensions: 2.375"H x 2.375"W x 1.25"D (60.3 x 60.3 x 32mm)

Exit Device Switch Kits 510 511 Switch kits are field installed in the inactive hinge pad of rim mount exit devices, mortise exit devices, concealed vertical rod exit devices and surface vertical rod exit devices. 512 514 516 517 518 519 525 528 527 Switch Contact: SPDT, 5 Amp @ 30VDC Applications: Activation of Delayed Egress Locks Electromagnetic Lock Release Request-to-Exit Alarm Shunt or Alarm Activation Model Make & Model to be Modified 510 Von Duprin 33, 35, 98, 99 510-2 Von Duprin 33, 35, 98, 99 DPDT 511 Von Duprin 55 512 Von Duprin 88 514 Dor-O-Matic 990, 1090, 1990, 2090 515 Sargent 9300, 9400, 9500 516 Sargent 9600, 9700, 9800, 9900 517 Adams Rite 8300, 8400, 8700, 8800 518 Precision Series 1100 518A Precision Apex Series (2100-2800) 519 Jackson 1095 519-2 Jackson 1095 DPDT 520 Corbin 3000 521 Corbin 7000 525 Monarch 18 and 19 525-2 Monarch 18 and 19 526 Corbin ED8200 527 Sargent 8800, Arrow S3800 527-2 Sargent 80 DPDT 528 Sargent 20/60 and Yale 2100 531 Yale 7000 (Dogging mechanism required) Corbin 4000 535 Kawneer Mid Panel Line Dor-O-Matic 1390 536 Jackson 1295 539 Cal Royal 9800 540 Arrow 542 Hager 4700 590 Dor-O-Matic 1690 Request-to-Exit PIR Sensor MD31D-W MD31D-B The SDC MD31D passive infrared detector is specifically designed for request-to-exit applications. It has an adjustable 1-60 second time delay. The coverage field is internally pointable. When angled 14º down, coverage may be 5 x 6 feet at 7 feet high to 10 x 12 feet at 15 feet high. The MD31D projects a wrap around U pattern down and away from the door to inhibit tampering. The MD31D may be mounted to the frame header, wall or ceiling. Complies with NFPA applications. MD31D-W PIR motion detector, white MD31D-B PIR motion detector, black Input: 12 or 24VDC/VAC @ 26mA max Contact: 2 SPDT dry, 2 Amp @ 30VDC Operating Temp: -20ºF to 120ºF (-29ºC to 49ºC) Dimensions: 1.5"H x 6.25"W x 1.5"D (38.1 x 148.8 x 38.1mm)

Latch and Deadbolt Monitoring Strikes MS-12 MS-14 Applications: Delayed Egress lock activation Latchbolt status Deadbolt status Alarm shunt Alarm activation Mantrap communication Common bath door communication Features: Strong trigger mechanism (not vandal prone sheet metal) Fits standard ANSI 2.75" or 4.875" strike (provided by others) Cylindrical; non-handed Mortise; reversible handing Standard ANSI frame preparation Vandal resistant Wide gap alignment adjustment Horizontal alignment adjustment Compatible with: Cylindrical locksets Mortise locksets Deadbolts Mortise locksets with deadbolts MS-12 SPDT Cylindrical latch monitor 2-3/4" MS-12D DPDT Cylindrical latch monitor 2-3/4" MS-14 SPDT Cylindrical latch monitor 4-7/8" MS-14D DPDT Cylindrical latch monitor 4-7/8" MS-16 SPDT Mortise lock latch monitor MS-16D DPDT Mortise lock latch monitor MS-18 SPDT Mortise lock deadbolt monitor MS-18D DPDT Mortise lock deadbolt monitor MS-20* SPDT Mortise lock latch and deadbolt monitor MS-20D* DPDT Mortise lock latch and deadbolt monitor *MS-20 and MS-20D are handed but reversible Contact: 5 Amps @ 12/24VDC Strike plate provided by others MS-16 MS-18 MS-20

www.sdcsecurity.com E-mail: service@sdcsecurity.com DPS-11 Ball Switch The SDC DPS-11 ball switch is compatible with swinging or sliding doors. Recommended uses include communicated doors, mantraps, auto re-lock switches and high current applications. Contact: SPDT, 5 Amps @ 30VDC Faceplate: 2.75"H x 1.25"W x 0.125"D (69.85 x 31.75 x 3.18mm) Switch Depth: 1.25" (31.75mm) Finish: 628 Satin Aluminum DPS-11 MC-4M Concealed Magnetic Contact Designed for vandal resistance, the SDC MC-4M is installed in the mortise of a hollow metal or aluminum frame and wood, hollow metal or aluminum door. Contact: SPDT, 100mA @ 30VDC Faceplate: 4.875"H x 1.25"W x 0.125"D (123.83 x 31.75 x 3.18mm) Switch Depth: 0.5" (12.7mm) Finish: 628 Satin Aluminum MC-4M MC-4 Magnetic Switch Ideal for door status monitoring, the SDC MC-4 is easily installed in hollow metal and aluminum doors and frames. Contact: SPDT, 250mA @ 30VDC Door/Frame Preparation: Gap: 0.75" diameter x 1" deep (19.1 x 25.4mm) 0.5" (12.7mm) MC-7 High Security Magnetic Switch Biased for high security door status monitoring, the MC-7 guards against false status indication caused by the presence of an additional magnet. Installed in hollow metal and aluminum doors and frames. Recommended for high security applications. MC-4 Contact: Door/Frame Preparation: Gap: SPDT, 250mA @ 30VDC 1" diameter x 1" deep (25.4 x 25.4mm) 0.5" (12.7mm) MC-7 SECURITY DOOR CONTROLS P.O. Box 6219, Westlake Village, CA 91359-6219 3580 Willow Lane, Westlake Village, CA 91361-4921 (805) 494-0622 (800) 413-8783 Fax (805) 494-8861 Email: service@sdcsecurity.com www.sdcsecurity.com