Intelligent technology made simple

Similar documents
The revolutionary code-free system as easy as

NAPCO FREEDOM F-8 CONTROL PANEL INSTALLATION INSTRUCTIONS. F-TP Touchpad

GEM-P801 Control Panel/Communicator For use with the GEM-RP8 or the GEM-K800 Keypads. Installation Instructions

GEM-P800. Control Panel/Communicator. Installation Instructions

The complete wirefree security alarm solution

Honeywell Control Panels FOR RESIDENTIAL AND COMMERCIAL INSTALLATIONS. Feature Charts

P Zone Expandable Hybrid Security System

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

GEM-P800 Programming Instructions

RANGER 7600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

GEM-P1664EX CONTROL PANEL/COMMUNICATOR

DESTINY OWNER S MANUAL

DESTINY 6100 SERIES SECURITY SYSTEM OWNER S MANUAL V1 12/01

ARMED STATUS NEXT/YES PRIOR/NO AREA. GEM-RP1CAe2 Keypad NEXT/YES PRIOR/NO AREA. GEM-RP2ASe2 Keypad

WIRELESS CONTROLS & DETECTORS

DL150 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

SILENCING AN ALARM When the alarm bell or siren is sounding, enter your user code or present your SecuraProx fob to your keypad.

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM AG100+ CONTENTS

Smart Security, Always Connected

Easy Series Intrusion Control Panel. Selection Guide

GEM-P3200 CONTROL PANEL/COMMUNICATOR

Installation Instructions

INSTALLATION GUIDE XTLN-WIFI PANEL

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

DS7400Xi Addressable Control/ Communicator

PROGRAMMING INSTRUCTIONS

D3D Wi-Fi GSM Smart Alarm System -User Manual

Wireless Devices. This chapter introduces the suite of DSC wireless sensors and devices used with the Impassa and other series of DSC alarm systems

RE6100 Series Helix Security and Automation Platform

PROGRAMMING INSTRUCTIONS

NetworX Series. NX-8 Commercial Fire Panel Installation and Startup

NX-148 LCD CODE PAD TABLE OF CONTENTS

Destiny Destiny Owners Manual

MAXSYS Zone Control Panel PC4020. Maxsys Commercial Fire Panel PC4020CF. MAXSYS 16 Output Module PC4216

All tested. Easy Series Intrusion Control Panel Making security easy featuring wlsn* * wireless Local SecurityNetwork

Control/Communicator Installation Manual

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

TABLE OF CONTENTS TABLE OF CONTENTS 1

TABLE OF CONTENTS. FOR THE RECORD 15 PROGRAMMING WORK SHEETS 16 CONTROL PANEL WIRING DIAGRAM inside back cover

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA 250BP ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

GEM-X255 CONTROL PANEL/COMMUNICATOR

RANGER 8980E DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

System Introduction. Digital Communicator Specifications: Supports all Major Formats including SIA and Contact ID Event Initiated Personal Paging

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Control/Communicator

DOOR MONITORING/DURESS SYSTEM

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

Testing the System. Battery Test. Dialer Test. Fire Drill Test (Code + [#] + 69) One-Man Fire Walk-Test (Code + [#] + 68)

How to Build Visonic PowerMaster Wireless Alarm Systems

INSTRUCTION MANUAL FOR: WIRELESS SECURITY STARTER KIT MODEL NO: SWSKIT

EVO192 v3.0 Fire and Burglary What s New

SECURITY ACCESS AND SURVEILLANCE SECTION VISTA-128FB ARCHITECT AND ENGINEER SPECIFICATION FOR SECURITY SYSTEM

PROGRAMMING PROCEDURES (Table 3)

RANGER 8600 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

OPERATING GUIDE for your GEMC-BK1 KEYPAD

ADEMCO VISTA-10P ADEMCO VISTA-10PSIA Security Systems

VISTA 48DLCT HONEYWELL SECURITY

System Introduction. 1.1 PC5015 Specifications S E C T I O N 1

CONTENTS. (User s Manual)

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

9,67$36HULHV 6HFXULW\6\VWHPV 8VHU*XLGH K5309-1V1 7/02

GEM-RP2AS/RP2ASe/RP2ASe2 Keypad

System Overview. PC4020 v3.3

LS800S Intruder Alarm System. Engineering Manual

Simon XTi Quick Operation Guide

USER GUIDE WIRE-FREE HOME PROTECTION SYSTEM WS-500X CONTENTS REV: 0.2 ERP P/N: ERP 机型 :SS21W2R-AU-EDP09940A-V1

ADEMCO VISTA SERIES User Guide

VISTA-32FBPT. Commercial Fire and Burglary Partitioned Security Systems with Scheduling. User Guide /12 Rev. B

SPECIAL CODES AUXILIARY CODES SYSTEM NOTES

Silencing an Alarm Note: Area Systems What to do when a trouble tone is sounding

One panel offers everything you want built-in

Safewatch Pro 3000 System Manual

icontrol OpenHome Converge Panel Interface Module Installation Guide Congratulations on purchasing your Panel Interface module.

&RPPHUFLDO%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Wireless Products HONEYWELL SECURITY & CUSTOM ELECTRONICS. Honeywell s quick-install wireless devices, with their

User s Guide FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA. K5309-5V5 11/08 Rev. A OFF 3 STAY 2 AWAY 1 OFF A B C D 5 TEST 8 CODE 9 CHIME FA260 # FA560

DL100 DOWNLOADABLE CONTROL COMMUNICATOR INSTALLATION MANUAL

**** **** A B ARMED FIRE FIRE C D READY OFF AWAY STAY 2 3 MAXIMUM TEST BYPASS PULL INSTANT CODE CHIME. First Alert READY. * 0 # Professional

USING DEVICE COMMANDS

XTL/XTLN/XTLN-WiFi USER GUIDE

VISTA-128BP/VISTA-250BP/ VISTA-128SIA Enhanced Commercial Burglary Partitioned Security System With Scheduling User Guide K5895V5 4/09 Rev C

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

Condominium Security Management System

NetworX Series NX-4V2 Control Panel Installation and Startup

ADEMCO VISTA SERIES VISTA-20P / VISTA-20PSIA VISTA-15P / VISTA-15PSIA Security Systems

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Silencing an Alarm. When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display.

TABLE OF CONTENTS. General Description Standard and Optional Parts List Feature Definitions Comments about the 8600E...

GEM-P9600 CONTROL PANEL/COMMUNICATOR

NX-4V2 Control Panel Installation Instructions

Integrated Security Solutions

Congratulations! This manual consists of four sections: SECTION 1 introduces you to the components of your CareTaker system.

ADEMCO VISTA-12A ADEMCO VISTA-12E

XTL Series USER GUIDE

System Introduction. 1.1 Specifications S E C T I O N 1

Intrusion. Control Panels

USER'S GUIDE FA1220CV. 2-Partition Security System N7003-1V2 7/98

HILLS Series LCD Code Pad User Manual

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Transcription:

Intelligent technology made simple Freedom F-64: 8 to 64-zone hybrid security system featuring multifunction talking custom alpha touchpad with intelligent exit/entry technology for up to 8 doors of code-free, false alarm-free operation Patented

Intelligent technology made simple... Every code-free, talking Freedom Touchpad controls up to 2 doors and has built in siren, Pet PIR, 4-zone expansion module & wireless lock receiver Smart exit/entry technology eliminates countdowns, codes & false alarm fears Intelligent customizable alphanumeric display shows lock/door status monitored by system. automatically dims in absence of activity. Great in bedrooms Built in 4 zone expander with 4 extra zones inside Wireless deadbolt lockdedicated receiver inside controls up to two doors per touchpad Built in Pet PIR with 25 wide angle coverage, monitors motion in room & deadbolt lock Powerful UL dual tone burglary/fire alarm siren built in saves on labor, time and equipment costs Voice prompt assist speaker Comforting human voice talks users through operation (with volume control) Designed with simplicity in mind. Simple to install one device seamlessly performing many functions for you. Simple to teach the absence of entry/exit countdowns & codes lets you deliver stress-free, false alarm-free intuitive operation. Simple to standardize on 8 to 64 hybrid zones & 64 users

Security as simple to use as locking the door Nothing to touch on the door patented Napco technology uses standard deadbolt & hole 1 Patented deadbolt lock status sensing tab is inserted into deadbolt lock hole (notching in tab-side slightly). 2 Drill directly through door jamb and wire lock tab to lock sensor on opposite side. 3 Deadbolt status and door (open) status, for up to 2 door locks, are transmitted wirelessly to the lock receiver on multifuntion keypad.* 4 Downloadable, Geminicompatible, panel works conventionally. Supports standard Gemini wireless. 3 * Up to 2 lock sensors can transmit to 1 touchpad (within 500 open air). 1 2 cut-away view

So simple, it maximizes account retention by maximizing customer satisfaction Coming home? Unlock the door, the system turns itself off. System confirms it, saying System disarmed, LCD agrees. Staying in or going to bed? Press STAY. System says Please lock door to arm in stay mode. LCD mirrors steps. Leaving? Lock the door & go! Freedom will remind you when you press AWAY, saying Please exit & lock door to arm system. (A tone heard outside confirms on.) F-64 Custom Alpha LCD Talking Touchpad with Alarm Siren & Pet PIR Features: Multifunction touchpads feature built in 4- zone expansion module, talking voice-aid assist speaker, 88db burg/fire alarm siren, wide-angle 25 Pet PIR and built-in wireless lock-dedicated receiver. Revolutionarily simple: Deadbolt-activated disarming; One-button, lock-activated arming, both with voice-prompts and LCD display usage messages. Zero exit/entry countdowns for stress-free, false alarm-free entry/ exits combining lock status sensing, motion detection and personpresent intelligent technologies (patented). Custom alphanumeric 2-line display and backlit keys with keypadcontrolled brightness adjustments. (Time/date line, selectable.) System supports up to 64 individually reporting users Monitor/control system from up to 8 locking doors using up to 4 system touchpads (any version touchpad, garage, bedroom, standard - see ordering info.) Each Freedom Touchpad can monitor 2 doors (locks), each by using F-2D Wireless Lock 2nd Door Interface kit on the second door. (Note: Transmission range of F-2D Lock Interface to touchpad s built-in receiver is approximately 600 open air). During arming/exiting, once lock is turned on outside door, touchpad s built in siren will chirp to verify to consumer the Freedom system is armed (programmable). Touchpads feature programmable panic, ambush and chime functions. 2 chimes by zone; programmable duration Alarm silencing port, which upon alarm, accepts any enrolled F-IFOB credential, silencing all system sounders (up to 64/sys.) Lost Key Mode feature, too (consumer enabled) Optional Bedroom Touchpad requires NO door lock on that room. One-touch Night mode - disables built in PIR. Also conveniently displays deadbolt lock status remotely, viewable from bedroom. (See F64 Accessories & Application sheet A521) Optional Freedom Automatic Garage Door(s) as the main entry/exit point, too. Activation of garage door motor takes place of deadbolt lock activation. (See F64 Accessories & Application sheet A521) F-64 8 to 64 Hybrid Zone Control/Communicator: 8 Hardwire or wireless zones on board, programmable by area Expandable up to 64 zones (through EZM multiplex modules and/or 4-zones built-in at each touchpad) Supports up to 4 areas 400 event log Supports 2-wire fire (2 zones) & 4-wire fire Supports Gemini Transmitters using 8, 6, 96pt. Gemini Receivers Supports 3 outputs; up to 16 external outputs (RB/RM3008) Programmable Telco line-cut and bell-cut PCD-WINDOWS (v5.4 or higher) - Familiar NAPCO PC programming and PC-preset All major communicator formats: SIA, Point ID, 4/2, etc. Fuseless, maintenance-free operation F64 System Specifications: Input Power: 16.5-18.0 VAC via CLASS 2 Plug-In 20VA, 40VA or 50VA Transformer Loop Current: 3mA; 5mA for 2-wire smoke-detector zones Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-detector zones Alarm Voltage Output: 1; Programmable Negative Outputs: 2 Auxiliary Power Output: 11.7-12.5 VDC Remote Power Output: 12 VDC regulated (for the F-64PROG Programmer (optional for keypad programming -not installed) Combined Standby Current - See WI1501 Freedom ordering information: F-64KIT1 Complete Freedom Kit: Touchpad w/built-in siren, downloadable 8 to 64 zone hybrid control, wireless lock sensor, deadbolt lock status sensor, 3ea. F-IFOBs (for alarm silencing,only), transformer. (Kit supports 2 codeless, key-controlled doors.) F-64TP/TAB For adding additional doors with multifunction touchpad and deadbolt lock status sensor. F-2D 2nd Door Add-on Kit, includes lock interfaces, for easy entry flexibility (without touchpad). F-IFOB Alarm-silencing credential fob (1) (F64 supports 64.) F-64TPBR Bedroom Touchpad with Night mode (no lock reqd.) F-64GKIT For premises entering/exiting primarily via automatic garage doors. Includes Garage Touchpad (wired) and Garage Door Motor Sensor (for 1 garage door). (See Accessories/Åpplications sheet A521.) Optional Gemini Wireless: GEM-RECV8, -RECV16 or -RECV96 Standard Gemini Wireless 8, 16 or 96 pt. receivers GEM-TRANS2 Window/door transmitter GEM-KEYF Gemini new small size mini keyfob GEM-KEYFLR Long range Gemini keyfob (classic) GEM-WP Wireless waterproof panic button GEM-SMK Wireless smoke detector GEM-HEAT Wireless heat detector GEM-PIR Wireless PIR GEM-PIRPET Wireless pet immune PIR GEM-RTRANS Wireless recessed transmitter GEM-DT Wireless dual technology sensor GEM-GB Wireless glass break detector For an online demo of FREEDOM by Napco go to www.napcoinsider.com 1-800-645-9445 631-842-9400 www.napcosecurity.com email: hotline@napcosecurity.com NASDAQ: NSSC NAPCO, 10/06. Prelim. specifications subject to change w/o notice. Freedom by Napco is a trademark of NAPCO. Patented A520

Freedom 64: Accessories & applications Freedom s garage door application is as convenient to operate as it is to install! Leaving Consumer presses AWAY on touchpad, gets inside vehicle, backs vehicle out of garage. When garage door closes, system arms. Optional chirp of siren can audibly confirm arming. Returning home Consumer opens garage normally, with standard garage door opener, and system automatically disarms. Intelligent entry/exit through automatic garage doors, too: 3-step application Step 1. Wire Garage Touchpad beside interior garage entry door (just like a typical keypad). Step 2. Garage Door Motor Sensor plugs in to garage door motor and wires to back of Garage Touchpad. 1 2 Garage kit and 2nd door add-on Add F-GDMS to kit for second garage door Step 3. Install standard overhead magnetic contact (of your choice) on garage door and wire to back of touchpad. It enables the system to detect the activation of the garage door and subsequent open/close of the contact on it to activate arming/disarming. 3 F64 System Complete Garage Door Kit, F-64GKIT with touchpad For 2nd garage door add F-GDMS

Freedom 64: Accessories & applications Add talking multifunction bedroom touchpad (no lock required) F-64TPBR Multifunction talking bedroom touchpad smart system & door control from the comfort of a bedroom and auto-dims backlighting in absence of motion Allows consumers to arm/disarm their system from a room without a deadbolt lock Door Locked?-Supervision monitors & displays door and lock status, so consumers know if their doors unlocked/ajar before going to sleep Includes 1-button disarm/silence in night or stay modes. Dual tone built-in siren can differentiate burglary alarms from fire alarm Night mode, turns on all interior devices, except Bedroom Touchpad s PIR. No lock required in bedroom Add garage door w/touchpad F-64GKIT Add 2nd automatic garage door F-GDMS Add garage touchpad, only F-64TPG 2nd Door Add-on Kit for easy entry flexibility (without touchpad) F-2D Add second door with LCD Touchpad F-64TP/TAB Freedom F-64 System add-on application options (require F-64KIT1. Max. 4 Touchpads, any type, per F-64 System): F-64TP/TAB For additional F64 System touchpad stations: Talking multifunction LCD touchpad w/built-in siren & PIR, plus deadbolt lock sensing tab. F-64TPBR Bedroom version F64 multifunction touchpad w/siren and PIR with night mode function. (doesn t require deadbolt lock) F-64GKIT Complete F64 Garage Kit, with LCD multifunction Garage Touchpad (hardwired) and plug-in automatic garage door motor sensor (F-GDMS) for interfacing with one garage door. (contains 2 items, below). F-64TPG Individual multifunction F64 LCD garagetouchpad w/ siren & PIR (for interior garage door entrance. Hardwired.) F-GDMS Freedom automatic garage door motor sensor (for adding a second automatic garage door, used in conjunction with F-64GKIT) F-MTAB Freedom mortise lock application tab (conceals longer strike plate area.) F-PROG64 Optional F64 keypad-style panel programming tool (for keypad programming similar to RP1) comes with convenient hands-free hanging bracket. (Note: Not for permanent installation.) For an online demo of FREEDOM by Napco go to www.napcoinsider.com 1-800-645-9445 631-842-9400 www.napcosecurity.com email: hotline@napcosecurity.com NASDAQ: NSSC NAPCO, 10/06 Specifications subject to change without notice. NAPCO Freedom is a trademark of NAPCO. Patented A521