WL2 Firewall Technical Manual

Similar documents
WL2000IT Technical Manual

CONGRATULATIONS ON CHOOSING THE WATERLOGIC 4 FIREWALL YOUR WATERLOGIC WATER DISPENSER

SERVICE REQUIREMENTS

Technical Manual Slim Tap UTS Big Tap UTS

SERVICE REQUIREMENTS

SERVICE REQUIREMENTS

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

PRE INSTALLATION PROCEDURES

PRE INSTALLATION PROCEDURES

SERVICE REQUIREMENTS

WL380 QUICK START GUIDE

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

PCB LED CODES. UV Purification Alert Replace UV Lamp

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

PRE-INSTALLATION PROCEDURE

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

PRE INSTALLATION PROCEDURES

A few simple steps to ensure perfect water, every time.

OPERATING, INSTALLATION, AND SERVICE MANUAL

Waterlogic 77 McCullough Drive Suite 9 New Castle, DE (888) Tech Portal Website wld-portal.waterlogic.com

A few simple steps to ensure perfect water, every time.

Contents Safety Warnings... 3 Unpacking... 5 Installation... 6 Product Overview Operation Cleaning Maintenance...

WL200 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

Waterlogic 77 McCullough Drive Suite 9 New Castle, DE (888) Tech Portal Website: techportal.waterlogic.com

DISPENSE TROUBLESHOOTING INDEX. Hot Tank Descaling Instructions are included in this Troubleshooting section.

WL400 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

WL350 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

Service manual NORDIC. Juice machine S / EN. Rev Din återförsäljare / Your retail dealer

SERVICE REQUIREMENTS

WL270 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

A few simple steps to ensure perfect water, every time.

USER MANUAL. Pharmacy Refrigerator Range. Applicable models: PSR353/PGR353 PSR273/PGR273 PSR151/PGR151

1. SAFETY WARNINGS INSTALLTION Location Reversing the Door Swing Levelling the Unit... 3

Slim Line Service Manual

USER MANUAL. Laboratory Refrigerator Range. Applicable models: LSR151 LSR288

Mix Boiler & Font Range ( #, #, #, , )

OPERATING, INSTALLATION, AND SERVICE MANUAL

REFRIGERATOR USER S MANUAL MODEL: HS-306LN

GCG-10. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-10-N33EB G-10-N33EB UPRIGHT COOLER

MIX Boiler & Font Range Service Manual

DELUXE COLLECTION Executive Filtered Water Cooler AQP-WCM-FBOT4

WL2FL-FX MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

WL100 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Autofill wall mounted water. boiler. Getting the best from your water. boiler. Please read and keep these instructions

USER MANUAL WATER DISPENSER WITH ICE MAKER

User manual NORDIC. Juice machine U / EN. Rev Your retail dealer

For Models FF2310APS, FF2310APW, FF2310APB 55cm FREESTANDING FRIDGE FREEZER. Instruction Manual

Vorton 11/18/36/55 2YEAR. GUARANTEE. Hozelock Ltd. Midpoint Park, Birmingham, B76 1AB. England Tel: +44 (0)

LARDER Instruction booklet

Progress plus Instruction manual

Zip Econoboil 1.5 litre White Zip Econoboil 3.0 litre White Zip Econoboil 5.0 litre White Zip Econoboil 7.

G-10f/GCG-10f UPRIGHT COOLER

Manual is for the following models: G-26 GCG-26 GCG-26-C31N* G-26-C31N* GCG-26-C231N* GCG-26-CA31N* *G,I,M,7,J plug. Instruction Manual.

WL380 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

Product Manual. Viscount IV series of carbonators and chillers. Part Number 3B3075 Issue 01 [ ]

Silver Undercounter Larder Fridge

GCG-9. Instruction Manual. G-Series Cooler. Manual is for the following models: GCG-9-N13EB G-9-N13EB GCG-9-B13EB UPRIGHT COOLER

PWC 7000 PureWaterCooler SERVICE MANUAL. for. PureWaterCooler by Vertex Model Copyright 2012 Vertex Water Products

DISPENSING TROUBLESHOOTING INDEX

INFRARED IP55 HEATER INSTRUCTIONS FOR: MODEL:- QZWP45N 1. SAFETY INSTRUCTIONS

STORM. Bottom-Load. Water Dispenser User Manual

THE HYBRID SERVICE GUIDE

Autofill counter top water boiler

WL290 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

WL290 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

FAULT CODES. Included in this section are instructions to Reset the two Hot Tank Overload Devices (High Safety Limit).

- 1 - Updated on 18 March, 2010

Hand Dryer Installation & User Manual

CUBE Firewall MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

LEC L6014W/S User Manual

FTM419A01W USER S MANUAL FROST FREE REFRIGERATOR

G-7s. Instruction Manual. G-Series Cooler COUNTERTOP COOLER. Part No.11IPA

TABLE OF CONTENTS FOR YOUR SAFETY

CHEST FREEZER USER GUIDE LEC CF61LW

LED Bottle Cooler. Maintenance for. I1457 Iss. 4 Jan 2014 Copyright Glen Dimplex Professional Appliances

4L Instant Water Boiler Instructions for Use

- 1 - Updated on 18 March, 2010

PWC-500/1000/1010/1500

ELECTRIC ASHCAN MODEL NO: ASHVAC1200 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: ORIGINAL INSTRUCTIONS

Health & Safety and Installation guide

USER GUIDE. Hot Water Dispenser. KA-HWD02 Series. Contents ,

Built-under larder fridge instruction manual RBL4. Contact Caple on or for spare parts

Water Boilers ME10EN, ME15EN. Table of Contents

Installation Instructions

POU(Plumbed-In) Water Dispenser User Manual

Radiant Heater. Instruction Manual QH-200 N13275

SLUSH PUPPiE MACHINE Instructions For Use

Instruction Manual for Electric Ovens OO757X OO986X

Instruction Manual Machine P/N: # & #

GCG-26c. Instruction Manual. G-Series Cooler

10. Water Dispensers

Autofill Wall Mount Boilers

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

WL270 MANUAL. Waterlogic International, LTD Global Headquarters Grenfell Road, Maidenhead, Berkshire, SL6 1HN, United Kingdom

Transcription:

WL2 Firewall Technical Manual

Technical Manual Welcome to your new Waterlogic machine. This Technical Manual is to help you get great tasting water cup after cup by making the most of the product s features. Index Machine Overview 4 Mains Parts Layout - Cold only 8 Mains Parts Layout - Cold and ambient 9 Main Parts Layout - Hot and Cold 10 Pre Delivery Inspection Procedures (PDI) 11 Installation Procedures 13 Operating Instructions 16 Maintenance and Servicing 18 Sanitising 19 De-scaling 20 Technical Specifications and Warranties 22 End of Life 24 ROHS 24 BioCote 24 Electrical Wiring Diagram 230V - Cold Only 26 Electrical Wiring Diagram 230V - Cold and Ambient 27 Electrical Wiring Diagram 230V - Hot and Cold 28 Wetted Parts Illustration - Wetted Parts List 30 Main Parts List Illustration - Freestanding model 32 Main Parts List Illustration - Mini model 36 Declaration Waterlogic International Ltd 1. The installation, maintenance and sanitizing procedures must be carried out by persons trained by Waterlogic International or their approved distributors. Do not remove any panels or covers unless acceptable in this instruction. 2. When any abnormal case happens, firstly unplug the appliance. 3. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety. 4. Children should be supervised to ensure that they do not play with the appliance. 5. This appliance can be used by children aged from 8 years and above if they have been given supervision or instruction concerning use of the appliance in a safe way and if they understand the hazards involved. Cleaning and user maintenance shall not be made by children unless they are older than 8 and supervised. Keep the appliance and its power cord out of reach of children aged less than 8 years. 6. Appliances can be used by persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. 7. Children must not play with the appliance. 8. If the supply cord or the detachable cord sets are damaged, it must be replaced by the manufacturer, its service agent or a similarly qualified person in order to avoid a hazard. 9. The detachable hose-sets and the connection kit used to connect the main water are supplied by the technician. Don t reuse the old ones. 10. The appliance is to be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA. 11. This appliance is intended to be used in household and similar applications such as - staff kitchen areas in shops, offices and other working environments; - farm houses and by clients in hotels, motels and other residential type environments; - bed and breakfast type environments; - catering and similar non-retail applications. 12. This appliance contains a UV-C emitter (UV lamp) 13. Unintended use of the appliance or damage to the housing may result in the escape of dangerous UV-C radiation. UV-C radiation may, even in little doses, cause harm to the eyes and skin. 14. Appliances that are obviously damaged must not be used. 15. The replacement of the UV lamp must be carried out by personnel trained by Waterlogic International or their approved distributors. 16. Read the maintenance instructions before opening the appliance. 17. The appliance must be disconnected from the power supply before replacing the UV lamp. 18. The UV lamp must be replaced at 6 month intervals or when necessary. If the unit is placed in a high use area, the UV lamp will need to be replaced more frequently. The quartz spiral can be cleaned by using an ultrasonic bath if needed. 19. WARNING: Do not operate the UV lamp when it is removed from the appliance enclosure. 2 3

Machine Overview WATERLOGIC WL2 FIREWALL The WL2 Firewall is available in the following options: a) Cold Only b) Cold & Ambient c) Cold & Hot When reading this manual, note the differences between the options and focus on the particular sections that concern the unit you have installed. COLD TANK The cold tank is manufactured from 304 Stainless Steel which is non-corrosive and inert. The cold water temperature is pre-set at approximately 5 C by the factory, this being the ideal temperature for a cold drink. The capacity of the cold tank is 4 litres for freestanding models and 2 litres for mini models. The cold tank temperature is controlled by a thermostat that is set at the factory. The thermostat set point is marked at the back of the machine by a small dot. If the WL2 Firewall UV light fails, then no cold water will be dispensed. HOT TANK The hot water tank has a 1.5 litre capacity for free standing and mini models. It is manufactured from 304 stainless steel and is heated by a 500watt heating element. The temperature of the hot tank is controlled by a thermister and it is pre-set at the factory at approximately 87 C. A BI-metal overload thermostat is fitted to stop the tank overheating and can be reset manually. Setting the hot water temperature at 87 C also helps stop scale forming in the hot tank. A special polyphosphate filter can be fitted at the customer s request, that will help inhibit lime scale formation. A minimum flow rate of 1litre per minute is needed for the hot tank to operate correctly. FILTERS The filtration system on the WL2 Firewall is designed to reduce dirt and sediment particles from the water. Furthermore, the Activated Carbon process will remove a whole range of contaminants e.g. chlorine and pesticides. There are many kinds of different filter combinations available from Waterlogic to suit local water conditions. 4 5

FIREWALL CHAMBER The Firewall chamber incorporates the in-faucet UV and is made of aluminium and is highly reflective. The chamber houses the UV lamp and quartz spiral as well as the faucet. IN FAUCET UV The unique design allows the faucet area to be sterilised before, during and after every dispense. There are two types of sensors available, the CDS UV sensor that detects if the UV lamp is working and the UV sensor that monitors the UVC intensity from the UV lamp. UV LAMP The UV light is a 15Watt germicidal lamp at a wavelength of 253.7 NM, which is very efficient at destroying bacteria in water. The UV lamp is situated in the Firewall chamber surrounded by a quartz spiral that attains NSF standard 55 purification of water. The lamp must be replaced at 6 months intervals, and the quartz spiral cleaned by using an ultrasonic bath if needed. PCB The PCB (Printed Circuit Board) is the control unit for the WL2 Firewall, it is responsible for the functions of all the mechanical and electrical parts (24V DC). There are two PCB s in this unit: a Display PCB and a Main PCB. COMPRESSOR The compressor operates at 220-240V at 50Hz. It uses 50 grams of R134a non- Ozone depleting refrigerant gas for the freestanding models and 40 grams of R134a gas for mini models. WATER PIPES AND FITTINGS The inlet and the internal water circuit pipe size is 1/4 and 5/16. The entire internal water circuit and all the components which come in contact with water are food grade NSF / WRAS approved. The cold and ambient water tubing inside the machine should not be exposed to water above 25 C. WATER VALVES Dispensing of water to the customer is achieved by means of a 24V DC electrical solenoid valve. The valves are energized every time the customer pushes the dispense button for a drink. DC voltage is used to give a positive and quieter action of the solenoid valve. PLASTIC PANELS The moulded panels are made from recyclable ABS plastic. All the ABS plastic panels are UV resistant and meet the standards of CE and UL. Please note that the WL2 Firewall should not be exposed to direct sunlight. Placing the WL2 Firewall in direct sunlight from a window, close to a radiator, or in a room of high ambient temperature, will affect the efficiency of the refrigeration circuit. 6 7

Wetted Parts Layout Cold only Wetted Parts Layout Cold and Ambient IN (Water) IN (Water) FILTER SOLENOID VALVE COLD SENSOR SOLENOID VALVE COLD WATER OUT FILTER SOLENOID VALVE COLD SENSOR AMBIENT WATER OUT COLD WATER OUT SOLENOID VALVE CONDENSER COLD TANK CONDENSER COLD TANK FILTER DRYER FILTER DRYER COMPRESSOR COMPRESSOR 8 9

Wetted Parts Layout Hot and Cold Pre Delivery Inspection Procedures (PDI) IN (Water) HOT WATER OUT CAUTION: Only competent trained technicians should work on Waterlogic products. Waterlogic units may weigh over 25KG. We recommend caution when lifting. Packing materials could present a trip hazard. Keep them off the floor. Take care not to allow the power lead to get wet. If the lead gets wet it must not be used. FILTER SOLENOID VALVE SOLENOID VALVE CONDENSER AIR VENT HOT TANK COLD SENSOR COLD WATER OUT COLD TANK SOLENOID VALVE 1. Unpack and carry out a visual inspection of the unit for any transit damage. 2. Remove the top cover and the lower front panel and visually inspect the internal parts of the machine for any wires or pipes that may have come loose in transit including the Firewall chamber. 3. Connect the water supply. 4. Ensure the switch on the rear of the machine is in the off position and connect the unit to a power supply. 5. The unit is now live and suitable safety precautions should be taken. COMPRESSOR FILTER DRYER 6. Flush water (approximately 10 litres) through the hot tank first until the water runs clear of any carbon fines. 7. Now flush water through the cold tank with approximately 10 litres of water. 8. Once you are sure that water is running through both the cooling and heating circuit then turn on the heater and compressor switch at the rear of the machine. 9. Carry out a visual inspection for any water leaks. 10. The hot water will heat to approximately 87 C. 11. To test the cold water wait until the compressor has shut off. Test the 2nd cup of water taken. It should be between 5 and 8 C. 12. Inspect the cold water produced for clarity and taste. If required flush more water to remove any adverse taste or carbon fines. 13. Return the switch to the off position and isolate the power and water to the machine. 14. Drain the hot tank and cold tank. 15. Replace all panels, clean the machine and repack the machine. 10 11

Installation Procedures 16. Waterlogic recommend that all units are fully electrically (PAT) tested on site by the commissioning engineer as damage may have occurred during transit to the unit s final destination. 1. Mount the WL2 Firewall on a firm flat surface with a 50mm air gap on both sides and top so that it cannot topple or fall from a counter top. 2. It is advisable that the water and electricity supply are within two meters of the WL2 Firewall and that the water isolation valve and power supply are accessible. The WL2 Firewall should not be installed using an extension lead. The water supply should be from a potable source. 3. Level the machine using the adjustable feet. 4. Remove the top cover of the machine. If you are installing a freestanding machine also remove the lower front cover. This is retained by two screws located under the front edge at the bottom of the cover and two clips in the same location. Remove the screws and push clips up to release. To gain access to the screws tilt the machine backward at an angle of 10 degrees. 5. Make the water connection using an installation kit. Waterlogic recommends the use of a pressure reducing valve, a shut off valve and a non-return valve. These should be fitted before the water intake to the machine. Minimum operating pressure for the machine to work suitably is 2.5 bar. The ideal operating pressure is at 3 bar. At pressures higher than 3 bar the machine will not function correctly and this can lead to leaks. 6. Please flush the water supply pipe until it runs clear, before making the water connection to rear of the machine. 7. The power lead is located in a recess on the top packing cover of the machine regardless whether it is a mini or a free standing model. Inspect the electrical socket, the machine plug and the power cable for any transit damage. Now plug the power lead into the back of the machine. As soon as you plug the machine into a suitable power supply voltage will be available to the PCB and solenoid valves and you can now start to flush water through the machine. Do not at this point turn on the heater and compressor switch at the rear of the machine. This switch should only be turned on once the hot tank is filled with water. 8. The hot water temperature is set at 87 C and the cold water temperature is set at 5 C at the factory. It is not possible to adjust the hot water temperature, but the cold water temperature can be adjusted by regulating the thermostat situated at the back of the machine. This thermostat is set at a specific point at the factory. This point is marked out by a small dot situated on the outside of the thermostat. It is advised that you do not adjust the cold thermostat past the factory set point of 5 C as this may result in the system freezing. 12 13

9. If installing a hot and cold model, do the following, otherwise go to point 10. Select the hot water option and press the dispense button to start flushing water through the machine filter and hot tank. The filter will produce carbon fines at first and the water may have a black appearance. Continue to flush 10 litres of water. 10. Select the cold water option and press the dispense button and flush for 10 litres of water through the cold tank. This will flush the filter and clean any residual water from the machine. 11. Check the machine for any water leaks and ensure that all water fittings are secured properly. 12. Once you are satisfied that water is passing through both the hot and cold tank successfully then turn on the heater/compressor switch at the back of the machine. The machine will now start to heat and chill. 13. The hot water will heat to approximately 87 C. 14. The cold tank will start cooling. When the machine has reached the target temperature the compressor will stop running. The temperature will continue to drop as any ice that has formed on the sides of the tanks will start to melt and equalize the tank temperature. 15. To test the water temperature, then please ensure that you use an accurate previously calibrated thermometer. 16. Please ensure that the cold water produced has a good taste. If you detect a plastic taste then it is an indication that the machine needs to be flushed again. 17. Check the machine to make sure it is electrically safe. 18. The WL2 Firewall should be sanitised at installation. 19. The WL2 Firewall must not be installed in direct sunlight, adjacent to a heat source, or in an ambient room temperature above 30 C or below 5 C. INSTALLATION KIT The WL2 Firewall must be installed according to the local guidelines and a pressure reducer must be installed as part of the installation. The pressure reducer should not be set higher than 3bar. The WL2 Firewall should not be connected to water supplies of unknown bacterial quality or those not already fit for human consumption. The WL2 Firewall should only be connected to a Potable drinking water supply. The filter on the WL2 Firewall must be changed every 6 months. The UV lamp on the WL2 Firewall must be changed every 6 months. The cold tank should also be flushed and sanitised every 6 months. Waterlogic International strongly recommends the use of an anti-flood device. Fig 1 is the recommended installation kit. 3 5 1 2 6 4 7 Fig 1. P-KIT-INSTALLATION 1. 15 mm Compression Inlet 2. Double Check Valve (great for carbonated water) 3. Adjustable Pressure Reducing Valve 4. Integral Isolator (with green adjustment knob) 5. Pressure Gauge Port 6. Waterblock 7. 1/4" Pushfit Outlet 14 15

Operating Instructions DISPENSING YOUR CHOICE OF WATER IS VERY SIMPLE, AS FOLLOWS: 1. Place your cup centrally in the dispensing area 2. Select the type of water you wish to be dispensed and press the corresponding button and then press the main dispense button. 3. Keep the main dispense button depressed until your cup has reached the desired level, and then release the button. COLD WATER Push Main button, LED shows green, it dispenses cold water. AMBIENT WATER Push Ambient button LED shows red, Push main button it dispenses ambient water. HOT OPTION EXTRA HOT OPTION COLD OPTION AMBIENT OPTION HOT WATER Push hot water button LED shows red, Push Main button, it dispenses hot water Note: Default mode is cold water. If you have a cold only machine you will only have available the main button. The option buttons are very simple to identify. The different options are indicated below. There will be a 2 second delay from the time that the button is pressed to the water being dispensed. Button 1: select hot water Button 3: select ambient water HOT WATER CAUTION Always place cup / mug in the centre of the drip tray. Always use a ceramic cup or a cup suitable for use with hot water. Do not hold cup or place hands in dispensing area whilst dispensing water. Do not dispense water in a stop start style of vending (Hold the button continuously until cup is full). Never try to fill more than one vessel at a time. Button 2: select cold water Main Dispense Button: to dispense water from selection 16 17

Maintenance and Servicing 6 MONTH SERVICE PROCEDURE This procedure should only be carried out by persons trained by Waterlogic International or their approved distributors. The following instructions cover models that can include Hot, Cold, Ambient. Every six months the filters and UV lamp must be changed. The Firewall quartz spiral must be removed, checked and cleaned every six months if needed. A WL2 Firewall with a hot water option may require having any calcium build up inside the hot tank removed, depending on local water conditions. No paperwork or cleaning records should ever be stored inside the WL2 Firewall. 1. Isolate the power to the WL2 Firewall by turning off the red switch and removing the power cord at the rear of the WL2 Firewall. 2. To access the filters, undo the screws and release the clips located in front of the lower front panel and remove the panel to gain access to the interior of machine. To access the filters on a mini machine just remove the top cover. This is a high voltage area and the machine should be isolated from the power supply. 3. When a valved twist filter head is installed there is no need to turn off the water supply; the water is automatically isolated when you remove the filter. 4. To remove the Waterlogic filters, twist the filter anti-clockwise. 5. The new filter will require flushing prior to being re-fitted in the WL2 Firewall. To do this connect a water feed directly into the inlet side of the filter and attach another length of pipe to the outlet side and direct this into a bucket/large container or drain, then flush through 10 litres of water to ensure that any loose carbon fines are fully removed from the filter to avoid any damage being caused to the machine. The new filter can now be installed into the machine. 6. Remove the UV lamp by unplugging the UV lamp connector and pulling the lamp upwards. 7. Check the quartz spiral for scale build up and clean if necessary. 8. Fit the quartz spiral back into the Firewall Chamber taking great care at this stage not to crack the quartz. 9. Replace the UV lamp assembly and re-connect it. Do not touch the UV lamp with bare hands. 10. Inspect the electrical and water connections of the machine. 11. Check the air gap around the machine to ensure it is not blocked. 12. Turn on the red switch, on the back of the machine. 13. Check that the UV lamp is alight by observing a blue glow from the top of the UV cap. Do not remove the lamp from the holder whilst ignited and do not look into an ignited UV light. 14. Close the front of the machine and the top of the machine by fitting the panels back to their original position. 15. Flush through 5 litres of hot and cold water to ensure the water is running clear of any carbon fines and that the taste of the water is clean and to the customers satisfaction. If you are not happy with the quality of the water continue to flush an additional 2-5 litres of water until you are satisfied with the taste. 16. Turn on the heater and compressor switch and allow the machine to cool and heat the water. 17. Clean the outside of the machine with a non-abrasive anti-bacterial wipe or cloth. 18. Taste the water one final time and check the machine is cooling and heating the water. SANITISING Items needed to carry out the sanitization procedure: An empty Waterlogic in-line filter housing. Rubber gloves. Antibacterial wipes or spray. Suitable test strips to work with your sanitisation fluid. A Phillips screwdriver. Sanitisation fluid. A 5 litre container. 1. Put on the rubber gloves to minimise the chance of any contamination to the machine whilst the sanitisation procedure is being carried out. 2. Turn off the water supply to the machine and release the internal pressure by 18 19

pushing the cold button momentarily. Then disconnect the water feed pipe from the bulkhead at the rear of the machine. 3. Measure 50ml of sanitising fluid into the empty filter housing and securely fasten the filter head. 4. Insert the water feed pipe into the inlet fitting of the inline filter housing containing sanitisation fluid. Attach a length of ¼ water pipe into the outlet fitting and insert the other end of the pipe into the bulkhead at the rear of the machine. 5. Remove the cartridge from the filter installed inside of the machine to avoid the mixing of sanitisation fluid and the active carbon, reattach the filter head securely. 6. The water supply to machine can now be turned on. 7. Dispense cold water until the sanitisation fluid leaves the faucet, by pressing the correct button for enough time until the colour of the test strip is changed by the water. Do not let any sanitisation fluid enter the hot tank. 8. Leave the sanitisation fluid inside the machine for a minimum of 20 minutes, when this time has been reached, flush water through the machine until there is no sanitisation fluid left inside. Replace the cartridge into the internal filter and remove the empty filter housing from the back of the machine, connect the water feed pipe directly into the bulkhead and turn water supply on. 9. Inspect faucet nipple and replace if cracked, damaged or if there is a calcium build up. 10. Isolate the power to the machine, then remove the quartz spiral by undoing the three screws on the top of the Firewall housing, disconnecting the UV sensor and water pipe, and removing the UV lamp. Inspect the spiral for any damage or calcium build up, if there is a large amount of calcium remove and replace the spiral and send it away to be treated by an ultrasonic bath. 11. Using the antibacterial wipes or spray, sufficiently clean the exterior panels of the machine, including the removal and cleaning of the WL2 drip tray and grill. DE-SCALING Items needed to carry out the de-scaling procedure: Rubber gloves. A container that can hold 5 liters. A funnel or syringe. A Phillips / Cross head screwdriver. De-scale solution. Non-abrasive antibacterial wipes or cloth. 1. Put on the rubber gloves to minimise the chance of any contamination to the machine and to protect yourself whilst the servicing procedure is being carried out. 2. Dispense 200ml of hot water from the machine and check that the water is hot, if the water is not hot allow time for the machine to heat the water up. 3. Switch off the power switche at the rear of the machine and completely remove the power lead from the unit. 4. Disconnect the silicone tubing from the top of the hot tank. 5. Remove the hot water drainage valve and drain about 200ml of water. 6. Add the de-scale solution into a container and mix it with no more than 200ml of water as per the manufactures instructions. 7. If you are using a syringe then draw the de-scale solution into the syringe and add the solution into the hot tank. If you are using a funnel insert the end of the funnel into the open hot tank outlet and pour the de-scale solution into the hot tank, this should be done slowly with both methods as adding the solution to quickly can result in the tank overflowing. 8. Reattach the silicone tubing onto the hot tank outlet and secure it with the fastening clamp. 9. Turn on the incoming water supply at the isolation point. 10. Reconnect the power lead and insert it into the rear of the machine. Turn on the power switches at the rear of the machine. 11. Leave the de-scale solution to stand in the hot tank for 15 minutes. Once this time has passed select the hot water icon and then the dispense button and flush 8-10 liters of hot water, through the machine. Taste test the water, if there is any hint of taste to the water flush a further 10 liters of hot water. 12. Clean the outside of the machine with the non-abrasive anti-bacterial wipe or cloth. 13. Taste the water one final time, if you detect any hint of taste, flush a further 10 liters of water. 14. Check the machine is heating and cooling the water by dispensing some hot and cold water and checking the temperatures. 20 21

Technical Specifications and Warranties SAFETY Subject to the standard terms and conditions of sale (a copy of which has been provided to you), neither Waterlogic International Limited ( Waterlogic ), nor any affiliated companies shall be liable for any damage which could affect, directly or indirectly, any person or property. Please be aware that any warranties accompanying the sale of our products will be invalidated by any of the following: Incorrect installation Incorrect use of the WL2 Firewall Unsuitable electrical and water supply Major short-coming of maintenance Technical interventions or alterations of an unauthorised nature Adoption and use of unapproved spare parts Engagement of untrained personnel Waterlogic has a policy of constant and continual improvement and therefore reserves the right to change specifications without prior notice, other than in the case of significant changes. Description WL2 FW HC WL2 FW C WL2 FW MHC WL2 FW MC Control & Unit Water Connection Cold Water Temp. 345mm(W) X 367mm(D) x 1030mm(H) 1/4 Hose 5-8 C 345mm(W) X 367mm(D) x 480mm(H) Hot Water Temp. 87 C N/A 87 C N/A Weight 29kg 27kg 26kg 25kg Power Supply 230 Volt / 50Hz Control & Unit 680 W 180 W 680 W 180 W Heater 500/800 W N/A 500/800 W N/A Refrigeration Gas 50g 50g 40g 40g Minimum Water Pressure Maximum Water Pressure Minimum Water Flow Rate (Litres per minute) 2.5 Bar 2.5 Bar 2.5 Bar 2.5 Bar 3.5 Bar 3.5 Bar 3.5 Bar 3.5 Bar 1lpm 1lpm 1lpm 1lpm 22 23

End of Life Non Eu Countries At the end of this product s life, please ensure that it is disposed of in an environmentally friendly manner which is in line with your Country requirements/ guidelines. WEEE (EU ONLY) Please be aware that our products are covered by the Waste Electrical and Electronic (WEEE) directive (2002/96/EC). The symbol shown above denotes that the product should not be disposed of with general/household waste. Please contact your supplier/service agent who will arrange for the collection and disposal of this product. ROHS All Waterlogic machines comply with EC Directive (2002/95/EC) on the Restriction of the Use of Certain Hazardous Substances in Electrical and Electrical Equipment (RoHS). BIOCOTE (ANTIMICROBIAL SOLUTION) For your added protection this product incorporates BioCote antimicrobial technology. Silver, in the form of silver ions, is the active ingredient utilised in BioCote. This silver technology is manufactured into the surface of our products, giving them built-in sustainable antimicrobial protection. BioCote s silver technology has been tested by an independent laboratory to show its ability to inhibit the growth of bacteria, mould and fungi by up to 99.9% over a 24 hour period and for the duration of the machine life. FREQUENTLY ASKED QUESTIONS ABOUT BIOCOTE : Why use BioCote? BioCote will help reduce the risk of cross-contamination. You may not want to think about it, but every surface in the working environment is a potential breeding ground for Bacteria. How is it applied? BioCote is applied via an additive into the manufacturing process and will, therefore, be present throughout the moulded or painted parts. How long will BioCote last? BioCote will last for the usual life expectancy of your water dispenser. It will not wear or wash out with use or cleaning. What bacteria is BioCote effective against? BioCote is effective against most common bacteria, moulds and fungi. Please note: BioCote is an additional line of defence to protect between cleaning routines, it is not a replacement for your normal cleaning and sanitisation processes. 24 25

Main PCB Schematic Diagram Cold only 230V Models Main PCB Schematic Diagram Cold and Ambient 230V Models 26 27

Main PCB Schematic Diagram Hot and Cold 230V Models 28 29

Wetted Parts Illustration Wetted Parts List N Part Description 1 2 4 3 5 23 22 6 7 20 8 21 9 12 13 14 15 17 18 10 11 16 24 19 1 JG Bulkhead Connector Union 1/4" * 1/4" 2 JG LLD PE Tube - Blue O.D.1/4" 3 Valved Twist Filter Head 4 Filter 5 JG LLD PE Tube - Blue O.D.1/4" 6 JG Equal Tee Connector 1/4" 7 Solenoid Valve DC24V 1000mm 8 JG Equal Elbow Connector 1/4" 9 JG LLD PE Tube - Blue O.D.1/4" 10 JG Equal Elbow Connector 1/4" 11 Cold Tank Assembly (4 Liters / No UV Holder) 12 JG Equal Elbow Connector 1/4" 13 JG LLD PE Tube - Blue O.D.1/4" 14 JG Equal Elbow Connector 1/4" 15 Solenoid Valve DC24V 1000mm 16 JG Equal Tee Connector 1/4" 17 JG LLD PE Tube - Blue O.D.1/4" 18 JG 3/8" x 1/4" Reducing Fitting 19 Faucet UV -Sprial Quartz 20 Solenoid Valve DC24V 1000mm 21 JG Equal Elbow Connector 1/4" 22 JG LLD PE Tube - Blue O.D.1/4" 23 JG Equal Elbow Connector 1/4 24 JG LLD PE Tube - Blue O.D.1/4 30 31

Main Parts Illustration Freestanding Model Spare Parts Numbers N Part Description 5 5 4 3 2 6 7 9 10 11 12 13 14 1 58 48 4655 47 56 49 50 16 17 18 1920 15 21 22 23 24 57 39 40 41 42 43 44 34 38 35 37 29 27 28 30 31 32 33 25 26 1 Top Cover Black 2 Thermostat Cold Tank 3 Silver Back Panel 4 Switch - Power 5 Fuse Holder & Fuse 220V/10A 6 Socket for Plug Connection 7 Gasket for Power Socket 8 Silver Side Panel 9 JG Bulkhead Connector Union 1/4" * 1/4" 10 Plastic Cap for 1/4" Bulkhead Fitting 11 Compressor 12 Down Base 13 Bolt 14 Unit Control Rubber Feet 15 JG Equal Elbow Connector 1/4" 16 Solenoid Valve DC24V 1000mm 17 JG Equal Tee Connector 1/4" 18 Solenoid Valve DC24V 1000mm 19 JG Equal Elbow Connector 1/4" 20 Cushion for Solenoid Valve 21 Filter Bracket 22 Filter Clip 3" 23 Valved Twist Filter Head 24 Filter 25 Front Down Panel 26 Front Down Insert Panel 27 Sensor fixing Rubber 28 UV Sensor 29 15W UV Lamp 30 Firewall UV Lamp Fixing Rubber 32 33

N Part Description 31 Faucet UV -Spiral Quartz 32 WL4 Spiral Quartz Spacer to Outer Quartz Sleeve 33 Faucet UV - Housing Faucet UV - Faucet Bracket Faucet UV - Housing Bottom Cover Faucet UV - Top Case 34 Wire from Ballast to UV lamp 35 JG 3/8" x 1/4" Reducing Fitting 36 Faucet UV - Top Case Cover 37 Silver Front Panel for Drip Tray insert 38 Firewall PCB Cover 39 Firewall Display PCB (Universal H&C,C&A,CO) 40 Silicon Button Key Mat CA 41 Firewall Front Upper Insert Panel 42 Button Label HC&CA 43 Drip Tray Grill 44 Drip Tray Body Charcoal 45 Firewall Hot Water Faucet 46 Solenoid Valve DC24V 1000mm 47 JG Equal Elbow Connector 1/4" 48 15W Electronic Ballast 49 Power Transformer 50 FS Upper Shelf 51 JG Equal Tee Connector 1/4" 52 JG Equal Elbow Connector 1/4" 53 Cold Tank Assembly (4 Liters / No UV Holder) 54 JG Equal Elbow Connector 1/4" 55 Main PCB Fixing Bracket Plastic PCB Support 56 Firewall UV Relay PCB (Universal H&C,C&A,CO) 57 FS Silver Side Panel 58 Wire Condenser 34 35

Main Parts Illustration Mini Model Spare Parts Numbers 8 10 9 5 6 12 7 11 4 2 3 13 14 1 56 15 1617 18 20 21 24 23 25 19 22 45-47 46 50 52 48 49 51 55 54 53 40 39 38 37 36 4435 41 42 43 26 33 34 27 28 29 30 31 32 N Part Description 1 Top Cover Black 2 Thermostat for Cold Tank 3 Mini Back Panel Universal 4 Switch - Power (Red) 5 Fuse Holder & Fuse 6 Socket for Plug Connection 7 Gasket for Power Socket 8 Silver Side Panel (Left) 9 JG Bulkhead Connector Union 1/4" * 1/4" 10 Plastic Cap for 1/4" Bulkhead Fitting 11 Compressor 12 Down Base 13 Bolt 14 Unit Control Rubber Feet 15 JG Equal Elbow Connector 1/4" 16 Solenoid Valve DC24V 500mm 17 JG Equal Tee Connector 1/4" 18 Solenoid Valve DC24V 500mm 19 JG Equal Tee Connector 1/4" 20 Cushion for Solenoid Valve 21 Mini Firewall Solenoid Valve Fixing Bracket 22 Mini Filter Fixing Panel 23 Valved Twist Filter Head 24 Filter 25 JG Stem Elbow Connector 1/4" * 1/4" 36 37

N Part Description 26 Sensor fixing Rubber 27 UV Sensor 28 15W UV Lamp 29 Firewall UV Lamp Fixing Rubber 30 Faucet UV - Spiral Quartz 31 Spiral Quartz Spacer to Outer Quartz Sleeve 32 Faucet Firewall Housing Firewall Faucet Bracket Firewall Housing Bottom Cover Firewall Top Case 33 Wire from Ballast to UV lamp 34 JG 3/8" x 1/4" Reducing Fitting 35 Firewall Top Case Cover 36 Silver Front Panel for Drip Tray insert - Firewall 37 Firewall PCB Cover 38 Firewall Display PCB (Universal H&C,C&A,CO) 39 Silicon Button Key Mat CA N Part Description 40 Front upper insert panel 41 Button Label HC&CA 42 Drip Tray Grill 43 Drip Tray Body Charcoal with WL Logo 44 Firewall hot water faucet 45 Main PCB Fixing Bracket (FS) 46 Plastic PCB Support 47 JG Equal Elbow Connector 1/4" 48 Solenoid Valve DC24V 500mm 49 JG Equal Tee Connector 1/4" 50 15W Electronic Ballast 51 Power Transformer 52 Mini Upper Base 53 JG Equal Elbow Connector 1/4" 54 Cold Tank Assembly (4 Liters / No UV Holder) 55 JG Equal Elbow Connector 1/4" 56 Wire Condenser 38 39

Speak to a Water Expert USA, Canada and Mexico info@waterlogicusa.com + 1 402 884 7212 Waterlogic USA, 11710 Stonegate Circle Omaha, NE 68164 Rest of the world exportsales@waterlogic.com + 353 1 293 1960 WLI Trading Ltd. Suite 4, 2nd Floor Beacon Court, Sandyford, Dublin 18, Ireland www.waterlogic.com ENG0017-19/05/14 40