Evaporative cooling process adaptive for Baghdad city climate

Similar documents
Chapter 10. Passive Cooling Contents

Analysis and Evaluation of a Passive Evaporative Cool Tower in conjunction with a Solar Chimney

Adelaide Homes Design Guide 4 - Winter warming

AND AIR-CONDITIONING. Dr Ali Jawarneh Department of Mechanical Engineering Hashemite University

Chapter 14 GAS VAPOR MIXTURES AND AIR-CONDITIONING

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

HVAC (Heating, Ventilating, and Air Conditioning)

Brine Generation Study

ABOUT THE SITE CITY PLAN LOCATION:NOIDA,SEC-59

Thermodynamics II Chapter 6 Mixtures & Psychrometry

EVAPORATIVE COOLING How an Evaporative Cooler Works

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

EXPERIMENTAL STUDY OF CENTRIFUGAL HUMIDIFIER FITTED IN AN INDUSTRIAL SHED LOCATED IN TROPICAL CLIMATES

Solar Passive Architecture Cooling Techniques

PROCESSING OF VEGETABLES IN A SOLAR DRYER IN ARID AREAS

AN ENVIRONMENT FRIENDLY COOLING OPTION

So far, we have covered the basic concepts of heat transfer and properties.

GROUND COOLING OF VENTILATION AIR FOR ENERGY EFFICIENT HOUSE IN MALAYSIA: A CASE STUDY OF THE COOLTEK HOUSE

How to ensure Thermal Comfort in buildings with CFD

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

climate BOOK MANUAL OF TROPICAL HOUSING AND BUILDING TOPIC 7.1 Shelter for hot-dry climate 7.2 Shelter for warm-humid climates

Solar Heating and Cooling Systems

Technical college/ Baghdad 4th Year Week No. :- 11. The objectives of this lesson are to: Introduction:

Energy Efficiency Solutions

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

1. COOL ROOFS. What is a Cool Roof

Passive Solar Home Design

Passive Solar & Low Energy Cooling Strategies

AR/IA 241 LN 231 Lecture 6: Passive Cooling

CHAPTER 4. HVAC DELIVERY SYSTEMS

Dynamic performance of a novel dew point air conditioning for the UK buildings

The effects of green spaces (Palme trees) on the microclimate in arides zones, case study: Ghardaia, Algeria

COST EFFECTIVE PASSIVE SOLAR FOR NEW HOME CONSTRUCTION

The Energy Consumption Investigation of the Hotel Central. Air-conditioning System and the Research of Energy Saving Measures

Heat Recovery Units. Heat Recovery 1

AIR CONDITIONING. Carrier Corporation 2002 Cat. No

Heat sinks for electronic cooling applications

MECHANICAL VENTILATION

MODULE 6 HUMIDIFICATION AND AIR CONDITIONING

TECHNICAL NOTE ON EVAPORATIVE COOLING. Renato Lazzarin, President of the IIR s Commission E1

Thermal Performance in Mid/ Large Buildings

Passive Cooling Systems

Atmospheric Moisture: Relative Humidity and Dew Point

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

How Much Energy is Really Being Wasted?

Integrated Building Environmental Design Case Study: Beijing Parkview Green

Incident Summary (II )

ENVIRONMENTAL STRATEGY FOR ROW HOUSE- CAPE TOWN

SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES 3/22/2012 REFRIGERATION

Comfort and health-indoor air quality

Effect of Operating Parameters on the Performance of Direct Evaporative Cooler

Smart Green Roofs: Cooling with variable insulation

Ultra Efficient Desiccant Based Evaporative Cooling for Air- Conditioning

December 6, 2018 Optimizing Solutions through Superior Dehumidification Technology SM

WHAT S UNDER YOUR ROOF?

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

ACHEIVING COMFORT IN SUBTROPICAL CLIMATES: BUILDING A MICROCLIMATE IN THE GUANGZHOU SCIENCE MUSEUM

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

DESIGN AND FABRICATION OF AN EVAPORATIVE COOLING SYSTEM. Md. Rakibuzzaman 1,* and M. A. Wazed 2. Chittagong-4349, Bangladesh 1,*

HVAC Equipment Access Equipment Location

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

The Effects of Green Spaces (Palme Trees) on the Microclimate in Arid Zones, Case Study: Ghardaia, Algeria

Scholars Research Library

- Murdoch University, Western Australia.

Understanding Water Use by Plants in a Cloche System - Gardening

TEACHER BACKGROUND INFORMATION Water Cycle

Open Access Operation Modes and Energy Analysis of a New Ice-Storage Air- Conditioning System

The Use of Evaporative Cooling Panels in Tie Stall Dairy Barns

ILASA Conference 2010

IMPLEMENTATION PROPOSAL FOR OUÉLÉSSÉBOUGOU CLIC, MALI: USAID/MALI

Performance Analysis of Solar Air Heater Using Three Wire Mesh

Desiccant Dehumidifier

2013 ASHRAE. Standards & Guidelines CD. Contents

Experimental Analysis and Performance Comparison between Evaporative Cooling System and Air Conditioning System

CASE STUDY. In the following, various case studies that have adopted solar passive design features are presented:

Speransa 2008: Round table: Nuclear and sustainable development Universitad Politecnica de Valencia \UPV - Passive safety systems -

ENERGY EFFICIENCY BRIEF REPORT

Technical Criteria for District Energy Ready Buildings Master Requirement ENG 108 Building Department: ,

INDIRECT EVAPORATIVE COOLING A PAST REVIEW

System-CoolAC. Bharatividyapeeth College of Engineering, Deekshant Bharti Scholar, New Delhi, India

Greenhouse Temperature Management

Appendix A. Glossary of Common Terms

Typologies of Hybrid Ventilation in Schools

Module 1: Introduction to Radiant Cooling. Pierre Jaboyedoff

Global Warming and the Hydrological Cycle

Building Science Basics

Indoor Moisture Control of Auckland Houses with Different Ventilation Systems

K.F. Fong *, C.K. Lee, T.T. Chow

Design and Development of Modified Air Cooler and Storage System

Connect North and South Korean Separated Families Higher Comfort Lower Energy

and is covered by a long north roof to shield it from the cold winter winds. In the Great Plains, sod substituted for wood, and subterranean shelters

Figure 1: Low energy dwellings testsite

Home. Cool Home. Home..Cool Home. Agenda. Comfort : Facts Ancient Techniques Modern Solutions Case Study Way Forward

Landscaping for Energy Conservation

Application Note Heat Transfer Design Team 7 Compact Inverter Jack Grundemann

Passive and Low Energy Cooling Survey

EFFECTS OF COMBINING SMART SHADING AND VENTILATION ON THERMAL COMFORT

Pakis-Stem Blocks as Natural Heat Insulation Diminished Room Thermal in Surabaya

Moisture Requirements of Grass, With Figures on Rainfall for , Inclusive

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

Transcription:

35 Evaporative cooling process adaptive for Baghdad city climate A. Al-musaed Elegancy & Design, Denmark ABSTRACT Human has developed a board rang of passive cooling techniques in various parts of the world up to a very impressive level of maturity: cliff dwellings through the world (ground cooling), wind towers (convective and mass cooling), sprinkling water with fountains (evaporative cooling), and whitewash (sun protection). All these cooling techniques were based on careful design in which heat and mass transfer principles did not make use of any mechanical energy: they were totally passive. The concept of evaporative cooling is that when water evaporates it absorbs a large quantity of heat from its surroundings. Evaporation occurs at whatever time the vapor pressure of water is lesser that the water vapor in the surrounding atmosphere. The phase change of water from liquid to the vapor state is accompanied by the release of a large quantity of sensible heat from the air that lowers the temperature of air while its moisture comfortable increases. The most familiar example of this is the cooling effect of evaporating perspiration on the human skin. In Iraqi, climates, body temperature is partially controlled by the rapid evaporation of perspiration from the surface of the skin. In hot climates with high atmospheric moisture the cooling effect is less because the high moisture content of the surrounding air. In both situations, however, the evaporation rate is raised as air movement is increased. Both of these facts can be applied to natural cooling of structures. The provision of shading and the supply of cool, dry air will enhance the process of evaporative cooling. Evaporative cooling is only effective for comfortable cooling in dry climates. When outdoor humidity rises, the cooling capability of direct evaporative systems declines unless occupants are willing to suffer with high humidity. Evaporative cooling techniques can be broadly classified as passive and hybrid. 1. BAGHDAD CLIMATE AND HOUSE TYPOLOGY 1.1. Baghdad city and climate Baghdad is the capital of Iraq. The city of Baghdad was founded in AD762 by Abu Jafar al-mansur, the second Abbasid caliph, on the west bank of the Tigris River. Circular walls enclosed the city and, although it s original name was Madinat as-salam (City of the Peace), it was more popularly known as the Round. Baghdad s climate is hot and dry in summer, cool and damp in winter. Spring and fall are brief but pleasant. Between May and September the average daily maximum temperature is 41 C, and the high may reach 49 C at midday in and August. Intense daytime heat is mitigated by low relative humidity (10 to 50 percent) and a temperature decline of 17 C or more at night. Table 1: Bagdad climate description for one year Baghdad, Iraq January February March April May June Dry October Dry May Dry September V Dry V Hot V dry X Hot X dry August September October November December X hot X dry X hot X dry X hot dry Warm dry Dry May Dry October 1.2. Baghdad house typology The houses from Baghdad are characterized by a small number of relatively small openings in the external façade, and a large number of openings that open onto the inner courtyard. Figure 1. Houses typology from Baghdad (Google earth) The inner courtyard is a garden and the center of household activities: all the rooms are set around it and open onto this gathering place. In large and medium sized houses, a fountain is placed in the center of the courtyard to freshen the air; Trees are also grown in many traditional courtyards, adding shade and life to this exclusive area. PALENC 2007 - Vol 1.indd 35 3/9/2007 1:23:21 µµ

36 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and Traditional Baghdad houses are known to be friendly environments, and are friendly in both their design and structure. For example, courtyards are equipped with many elements that help humidify the air (trees and fountains); they also use the IWAN as an open summer sitting room facing north. The thick walls and roofs are good insulators and help stabilize room temperature, while the variable roof heights and protruding elements in the facade provide shade. 2. EVAPORATIVE COOLING SYSTEM 2.1. Overview Evaporative methods can be used to enhance the cooling rates in convective cooling systems. One way of doing this is to bring the outdoor air into the house through a moist filter or pad. Passive cooling methods with earth tubes and / or cool towers use the same principles but utilize natural systems for air driver and distribution. If underground intake pipes are made from a porous material, and ground above them is well cool and watered, some evaporation will occur at the inner surface of the pipe. Cool towers utilize wet cooling pads, and the force of gravity. Heavier, cool air falls, via gravity, into the house and its momentum floods the habitable area. The cool tower exploit, as well as that of the earth cooling tubes, can be improved and distribution comprehensive, by the placement of thermal chimney drivers which can pull the cooled air through the house with an increase in both air quantity and velocity. In the either case, the cooler air now has an upper relative humidity, but this is not usually a problem and can even be a benefit in Baghdad climates. In some times of Baghdad s summer, they may be a time of higher humidity, south and south west desert monsoon season. While sensible heat continues to be mitigated by passive cooling techniques, the latent heat contained in the humid air is more difficult to dissipate, which renders evaporative cooling less effective. The rate of evaporation is greatly enhanced in such a system because a much larger surface area is exposed to the night air. With all evaporative cooling methods, it is important to maximize airflow across the exposed water. Fresh air must be continually available to replace the humid air being built up near or over the water. Failing this, air will be quickly saturated with water vapor, and the evaporation and cooling rates will decline abruptly. Two-stage evaporative system can also be combined hybrid solar systems using the same storage (rock bed) system for both seasons. This type of systems is necessarily suited for new construction because of the requirement for the rock bed, which is most effectively located beneath the structure. It works well during hot, humid periods in the southwest using only slightly more power than direct evaporative cooling and the comfort attained is similar to that of refrigerated air-conditioning. Atypical system consisting of two evaporative coolers and a large rock bed is shown in illustrative examples at the end of this part. At night, one evaporative cooler cools the rock bed while the other cools the house using a one-stage evaporative cooler. During the day, hot outside air is drawn through the night-cooled rock bed where it is pre-cooled before entering the main house evaporative cooler. Since no moisture has been deposited in the rock bed, the pre cooled air has not had moisture introduced into the house. A good-looking feature of this type of system is the combining of heating and cooling system in order to make the best possible use of components during the whole year. An air heater may be used to provide hot air during the heating season to the rock bed where the rock bed, fans, ducts and many of the control systems are used both during the heating and cooling season. 3. EVAPORATIVE COOLING SYSTEMS TYPES There are two diverse approaches to cooling house by evaporative cooling systems. The first is to cool outdoor air directly through evaporation, after that introduce that air into the house. The air is humidified while its temperature is lowered and the indoor moisture content is elevated above the outdoor level. This is the direct evaporative cooling affecting the users and the interior materials in the cooled space. The airflow for direct evaporative cooling can be induced either by mechanical devices fans or passively by natural processes utilizing the wind, temperature difference, or water spray in passive evaporative cooling towers. The second approach is to cool a given element of the house, such as the wall, roof, windows, doors, etc. The cooled element, in turn, serves as a heat sink and absorbs, through its interior surface, the heat that penetrates into the building through the envelope or that part of heat generated indoors. This approach is indirect evaporative cooling. With such systems the indoor radiant and air temperatures are lowered without elevating the indoor moisture content of the air. 3.1. Direct cooling systems This system applied to comfort cooling by application the simply add moisture to a moving air stream to cool the air while add to its humidity. In this system can be used of vegetation for evapotranspiration, as well as of fountains, pools and ponds where the evaporation of water results in lower temperature in the room. The procedure of cooling is only work for a moving air stream; PALENC 2007 - Vol 1.indd 36 3/9/2007 1:23:22 µµ

37 therefore this approach requires a source of air drier than the air in the living space that must be cold. An important procedure known as Volume cooler is used in traditional architecture. The system is based on the use of tower water contained in a jar or spry is precipitated. External air introduced into the tower is cooled by evaporation and then transferred into the house. A contemporary version of this technique uses a wet cellulose pad installed at the top of a downdraft tower, which cools the incoming air. Natural down-draft evaporative cooler are devices recently developed at the University of Arizona s environmental research laboratory. These towers-like devices are equipped with wetted pads sprays at the top which provide cool air by gravity flow. These towers are often described as reverse chimneys; just as the column of warm air in a chimney rises, the column of cool air, in this instance, falls. The air flow rate depends on the efficiency of the evaporative cooling device, tower height and cross section, as well as the resistance to air flow in the cooling device. The experiment shows that the cooling tower decreased the temperature from 41, 7ºC air surrounding to 23, 3ºC at the 3:00pm internal space. The wind tower, is used in many hot arid countries, literally scoops air from the prevailing wind stream. The incoming air is evaporative cooled as it passes over receptacles of water, and warm air is expelled via leeward openings. Others systems that can be useful to be used for Baghdad s climate are wetted layers or volumes of water, spring water, and vegetation, that take place in the front of external doors, windows, catching wind, perforate faces in facades, or special volumes, in which warm air stream penetrated via wetted front or volume to be cold. For intelligent cooling system, mechanical forces can be used to drive air stream from the cooler sources by conducts to living space that must be cold, the capacity of this ventilator can vary between (20-50W). Figure 3: Window hybrid evaporative cooling unit Water quality is important to the longevity and performance for any direct evaporative system. Minerals in the supplied water will concentrate in the sump and eventually begin to create scale or deposits on the pads. These deposits can severely degrade the efficiency of the systems, so a water treatment system such filters, such as changing periodically of the water can be useful. Direct cooling system include also establishment of an wet obstacle for cooling, this obstacle can be from straw, plastics thread lines (net) with water which raining down (simulation of natural raining form), warm airflow through this net to be cold. 3.1.1. Cooling by fretwork profiled front This arrangement consist of interior kernel spaces include wet sand or other material connected by special canals using for function the capillary phenomenon, all these systems existing in a perforate front, where natural warm airflow passing through the fretwork front, which captured cool from the front. Figure 2: Underground hybrid cooling unit PALENC 2007 - Vol 1.indd 37 3/9/2007 1:23:22 µµ

38 2nd PALENC Conference and 28th AIVC Conference on Building Low Energy Cooling and A tank of water is located in a special tight space which is located between the underground and the artificial ceiling or any others solutions. The condition of this situation is tightly and well thermal insulated of cooling space. 3.2. Indirect cooling systems This system of cooling to reduce the external air temperature is characteristically accomplished in swine conveniences through the use of evaporative cooling pads. As air is drawn through wet cooling pads, water is evaporated into the air causing the temperature to be reduced at the same time as increasing the moisture level. Indirect evaporative cooling techniques include roof spray and roof bond systems, earth cooling tubes. Airs in this situation don t need adding moisture. This systems are very expensive and consumption more energy than direct system. Figure 4: Window Passive evaporative cooling unit. This front can take place in the front of opening on façade or in the front of house, or such as shading covering element or volume. 3.1.2. Cooling by using of cold water storage in a tank Water is come directly from water station by steel pipes locate underground; therefore this water is permanent cool. The idea of this cooling system consists of an envelope of brick, steel, plastic or solid well thermal isolate, including a spiral plastic or steel form which covered water storage tank situate underground or above of earth surface in special tight space. The warm air inters via the tank space components to get in final a cool with helping of an exhaust fan. 3.2.1. Roof spray system The exterior surface of roof is kept wet using sprayers. The sensible heat of the roof surface is converted into latent heat of vaporization as water evaporates. Night spray on roof surface cools water by evaporation and radiation to 5 to 8ºC below minimum night air temperature. This cools the roof surface and a temperature gradient is created between the inside and outside surfaces causing cooling of the house. 3.2.2. Roof bond system The roof bond consists of a shaded water pond over a non-insulated concrete roof. Evaporation of water to the dry atmosphere occurs during day and nighttime. The temperature within the space falls as the ceiling acts as a radiant cooling panel for the space, without increasing indoor humidity levels. The limitation of this technique is that it is confined only to single storey structure with flat, concrete roof and also the capital cost is quite high. 4. CONCLUSIONS Evaporate cooling can be direct if bay air is blown directly in the wet media, in this case evaporative cooling provides sensible cooling while increasing latent content of air. Evaporative cooling can also be indirect, when outside air cooled directly through the evaporative cooler transfers its coolth to the indoor air to be conditioned through an air to air heat exchanger. In that case, evaporating cooling provides sensible cooling while keeping constant the latent capacity of air. Figure 5: Cooling by radiant system. PALENC 2007 - Vol 1.indd 38 3/9/2007 1:23:22 µµ

39 REFERENCES Al-musaed, Amjad. PLEA2006. Bioclimatic interpretation over vernacular houses from historical city Basrah. The 23th Conference on passive and low energy architecture Geneva, Switzerland. Al-musaed, Amjad. Biophilic architecture, PLEA2006, the concept of healthy sustainable architecture, The 23th Conference on passive and low energy architecture, Geneva, Switzerland. Al-musaed, Amjad. 2004. Intelligent sustainable strategies upon passive bioclimatic houses, Arkitektskole in Aarhus,. Aarhus, Denmark Al-musaed, Amjad. 1996. Town texture specific for the warm zone, A.D review, issue nr 12-1996, Bucharest, Rumania. GIVONI, B, 1994, Passive and low energy cooling of buildings. New York, USA GIVONI, B. 1997, Performance of the shower cooling tower in different climates. Renewable Energy, v.10, N.2/3. http://members.aol.com/watsonwx/worldclimate/baghdad.htm PALENC 2007 - Vol 1.indd 39 3/9/2007 1:23:22 µµ