WhisperControl & EcoSwitch

Similar documents
2012 Ventilation Fans

Lodging/Hotel. Panasonic Ventilation Fans

FV0511VQ1 (Fan Only) FV1115VQ1 (Fan Only) FV0511VQL1 (Fan/Light) FV1115VQL1 (Fan/Light) Yes Yes Yes Yes

Residential Balanced Ventilation Systems

FV-08VKML1, FV-08VKSL1, FV-08VKM1, FV-08VKS1, FV-08VKL1, FV-08VK1, FV-05VK1

The 2018 Ventilation Extravaganza. Rick Karg Residential Energy Dynamics 2018

Ventilation Strategies in Weatherization

Ventilation Solutions. Bathrooms

Wholesale Products Catalog

The Safer Living Collection

IT S ABOUT TIME FOR FRESH AIR.

INDEX. Page 2 to 7 Electrical Specifications. Page 8 Electrical Schemes: Basement Plan. Page 9 Electrical Schemes: First Floor Plan

INSTALLATION INSTRUCTIONS

LEED for Homes Points

Electric Heat - Air Curtains

Specifications Occupancy/Vacancy Sensors CSI ASHRAE AIA Division 16 Section 16950

breeze easytm model # F100-1W

Tempra Series WHOLE HOUSE TANKLESS ELECTRIC WATER HEATERS. Whole House Comfort. Germany

Volume 1: Basic devices and single-space systems

Energy Efficiency (CFM/Watts)* Watts PC /31 0.1/ / / / /63 <0.3

BRONZE MODELS 90H* 190H READ AND SAVE THESE INSTRUCTIONS

Featuring Vent Lights and Premium Grilles

Ceiling Mount Sensors B4-B9. Occupancy and Vacancy Sensors B10-B15 B16-B17. Wall Mount Occupancy Sensors B-1

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

Lighting and Fan Speed Controls

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

Ventilation Products. Climate Communicator

CONTENTS WIRING DIAGRAM

Wall, Ceiling and Floor Heaters. Commercial & Industrial Electric heating and controls

Ventilation Products AirCycler g2/g2-k Installation & User s Guide

Over-the-Range Microwave professional series

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

Abella Digital Fade Dimmer

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

Ventilation Products AirCycler g2/g2-k Installation & User s Guide

π H-6369, H-6370 DEHUMIDIFIER GENERAL INFORMATION uline.com WATER IN THE BUCKET RECOMMENDED HUMIDITY LEVELS WARM AIR EXHAUST IS NORMAL

Fits-More Capacity. Extra-large microwave provides 1.6 Cu. Ft. of cooking space and will hold almost any dish even a 13" x 9" baking dish.

CONTENTS DESCRIPTION UNPACKING DIMENSIONS

PART NO. COMBUSTION AIR CAP

Bathroom Ventilation

100A / 200A. Maximum Heating Load: Enclosure Type: NEMA 4

Featuring Bake & Brown Convection Product Dimensions. Bake & Microwave Option

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

USER MANUAL 2000NC MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. Builder Series 5-2 Day Programmable Single Stage Heat/Cool Digital Thermostat

DRI-AIR INDUSTRIES, INC. AHM-1B HOPPER MOUNT DRYER OPERATING MANUAL

Serenity Series Auto Sensing Everything Bathroom Fan

ST 53.1 User s manual

Portable Dehumidifier

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130)

PLATINUM. Commercial Unit Heater Program PLATINUM. Electronic Platinum KB Platinum. Includes It All. Featured Inside: Includes It All.

AirCycler g2-k Installation & User s Guide

Portable Dehumidifier with Internal Pump

OPERATION GUIDE MODEL CERV-001-PARTA, CERV-001-PARTB CONDITIONING ENERGY RECOVERY VENTILATOR (CERV)

MANDATORY MEASURES INDOOR LIGHTING CONTROLS. (Reference: Sub-Chapter 4, Section 130.1)

HEAT RECOVERY AND ENERGY RECOVERY VENTILATORS

Report No CRT-414

Thermostats... loaded with features, designed for value!

Remote Air Cooled Condensers C2 Series

IMPORTANT SAFETY INFORMATION:

Please Read and Save These Instructions Safety Information

The Silent Range Pure Elegance & Tranquillity. The widest range of ultra quiet silent fans

INSTALLATION GUIDE

Flow Solutions Valves for Heating System Control

FerronTM. Instruction Manual A Kichler Decor ceiling fan

Model 8191 & 8192 Ventilator with Dehumidification Installation and Operating Instructions

MultiFamily Ventilation Updates: ASHRAE 62.2, Best Practices and Practical Applications RESNET Conference Atlanta, GA

T HE V IZIA C OLLECTION

LOADS AND LOADS AND LOADS OF QUALITY.

Ventilating Fan FV-05VFL2 FV-08VFL2 FV-11VFL

Indoor Air Quality Product Brochure.

EC Series Wall Unit Humidifier

AIR KING VENTILATION PRODUCTS

USER GUIDE MODELS ERV CONSTRUCTO 1.5 QUATTRO ERV CONSTRUCTO 2.0 QUATTRO READ AND SAVE THESE INSTRUCTIONS FOR RESIDENTIAL USE ONLY rev.

ECOTOUGH CONDENSING TECHNOLOGY TAKING TANKLESS TO A NEW LEVEL OF EFFICIENCY

Product Specifications. Vertical Floor Consoles By First Co.

Dual Relay Multi-Technology Wall Switch Occupancy Sensors

DIGITAL QUARTZ INFRARED HEATER. Model No.: SPP1500SBH

ValkyrieTM. Instruction Manual. Includes our new CoolTouch TM 6 Speed DC Control System Looks permanent, but goes wherever you go! U.S.

Applied Lighting Controls

USER MANUAL MODEL READ ALL INSTRUCTIONS BEFORE PROCEEDING. 5-2 Day Programmable Multi-Stage 2 Heat/1 Cool Heat Pump Digital Thermostat

Hydronic Air Handler Powered by Tankless Technology

CONTENTS. Vitro Series Z Series LD Series MA Series X Series VKO 1 Series MAO 1(MAO 2) Series VN Series K Series Accessories Order code

DRI-AIR INDUSTRIES, INC. AHM-1C HOPPER MOUNT DRYER OPERATING MANUAL

Portable Dehumidifier with Internal Pump Portable Dehumidifier with Internal Pump OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS

SECTION I: EXISITNG SYSTEM AND PROPOSED SYSTEMS

Ventilation Solutions

Model Numbers: HCT-D30-A (TDA30) HCT-D45E-A (TDA45E) HCT-D70E-A (TDA70E) Portable Dehumidifier Operating Instructions V

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

IllumaTech Innovations

Applying the latest version of the National Ventilation Standard Heyoka Solutions, LLC Paul H. Raymer

Indoor Air Quality Product Brochure.

Electrical Systems. Electrical Plans. Electrical Plans. Essential to ensure. National Electrical Code (NES) Consider electrical needs.

Heating Controls Technical

Over-the-Range Microwave

VEX100 series Air handling units with cross-flow heat exchanger

SpaceWise Rack Our SpaceWise Rack creates more room so you can cook multiple dishes at once.

ChicagoTM. Instruction Manual. Includes our new CoolTouch TM Control System Looks permanent, but goes wherever you go! U.S.

dmev Unit Quietest dmev available. Discreet, tasteful styling. Single fan for use in all applications.

Selection Guide. Tastic Eco Tastic Easy Duct Tastic Easy Duct Smart Switch Tastic. 5 Year in home warranty.

HMT-D30-A HMT-D45E-A HMT-D70E-A. Model Numbers: HMT-D30-A HMT-D45E-A HMT-D70E-A. Portable Dehumidifier Operating Instructions V.

Transcription:

Condensation Sensor Plus FV-WCCS1-W, FV-WCCS1-A On/Off (White & Light Almond) FV-WCCS2-W, FV-WCCS2-A On/Off/Light (White & Light Almond) WhisperControl & EcoSwitch FV-WCCS1-W FV-WCCS2-A n Intelligent and advanced sensor technology monitors humidity and temperature to anticipate dew point, automatically operating the fan to control moisture n Automatic seasonal adaptability with optional Moisture Sensitivity Selector that allows fine tuning for dry or moist environments n Adjustable Minutes Per Hour (MPH) Fan Timer ensures consistent and controlled ventilation throughout the day for compliance with ASHRAE 62.2 n Includes manual on/off fan control n 20 minute delay off timer initiates once fan is manually turned on ADDITIONAL BENEFITS 8 Amp max load Compatible with all single speed fan and fan/light models Stylish decorator design with wall plate included Blue LED light indicates when the fan is on 2 year limited warranty* Can be used to comply with ASHRAE 62.2, LEED, ENERGY STAR 3.0 and CALGreen * One year additional fan warranty available when a Panasonic WhisperCeiling/Lite, WhisperValue or WhisperFit/Lite fan is controlled by the Panasonic Condensation Sensor Plus.

Condensation Sensor Plus CONDENSATION SENSOR PLUS Example: Using a measured airflow of 80 CFM on a vent fan and setting the MPH fan timer to run 30 minutes per hour will instantly make it equivalent to a 40 CFM fan running 24/7. n Moisture Control Automatically turns on exhaust fan to control moisture. Advanced, patent pending sensor technology detects humidity and temperature for superior accuracy. Fan automatically turns off when the optimum dryness level is met, in all climate zones and for all seasons. n Moisture Sensitivity Selector Allows you to adjust for sensitivity based on your regional climate, the size of your bathroom and your preferred dryness level. The patent pending technology tracks temperature and humidity over several weeks to determine the level of dryness your room needs to return to. When the Condensation Sensor Plus turns on, the room will be dried out to the level that was averaged over this period of time. The Moisture Sensitivity Selector is not affected by daily or seasonal changes in your room s climate so you can set it once and forget it. n Adjustable Minutes Per Hour (MPH) Fan Timer Set the MPH fan timer to have the fan come ON for a set amount of time every hour (0-60 mins.) for compliance with ASHRAE 62.2. The MPH fan timer provides constant and controlled ventilation every hour. The MPH Fan Timer will also credit any manual use time to the next hours operation (up to 3 hours ahead). This credit for manual use saves energy by conserving heated or cooled air. n Manual On/Off Control Simply push the switch for manual fan operation and if you ve turned your fan off before the room has been adequately cleared of moisture, the Condensation Sensor Plus overrides the operation to ensure your exhaust fan removes the moist air. n Delay Timer Manually turning the fan on initiates a 20 minute countdown cycle. During automatic operation, a 30 minute countdown timer initiates after moisture returns to normal levels. Minutes Per Hour Fan Timer High Sensitivity Setting the Condensation Sensor Plus to it s most sensitive setting covers the widest range of humidity. This is a setting for dryer climates and/or larger rooms. In a very dry environment, higher sensitivity is needed. Average Sensitivity The Condensation Sensor Plus comes factory set to this most common setting. Moisture Sensitivity Selector Low Sensitivity The least sensitive setting is used in hotter and more humid climates. In a very moist environment, low moisture sensitivity may be needed to avoid excessive fan run-time. Timer and Sensor Settings On/Off FV-WCCS1-W (White), FV-WCCS1-A (Light Almond) On/Off/Light FV-WCCS2-W (White), FV-WCCS2-A (Light Almond) WhisperControl Condensation Sensor Plus FV-WCCS1-W/A FV-WCCS2-W/A ing ing Blue LED Blue LED Amperage Maximum Fan Load 8 Amp 8 Amp s s Dry Contact Switching 24 Volt AC Input/Output 24 Volt AC Input/Output Termination 6" Leads 6" Leads Connections (Copper Wire Connections) Use #14 or #12 Use #14 or #12 Max. Fluorescent Light Load NA 400 Watt Standard Certifications

Preset Countdown and Hourly Timer PRESET COUNTDOWN AND HOURLY TIMER On/Off FV-WCD01-W (White) FV-WCD01-A (Light Almond) On/Off/Light FV-WCD02-W (White) FV-WCD02-A (Light Almond) n Preset Countdown and Hourly Fan Timer Preset the fan timer anywhere from 5-60 mins. When the fan turns ON, the timer will run the fan for the selected period of time then shut the fan OFF automatically for you. This feature is great for tenant and family use. n Adjustable Minutes Per Hour (MPH) Fan Timer Set the MPH fan timer to have the fan come ON for a set amount of time every hour (0-60 mins.) for compliance with ASHRAE 62.2. The MPH fan timer provides constant and controlled ventilation every hour. It also sees when you ve used the Preset Countdown Fan Timer and will temporarily suspend fan operation to avoid excessive run times. If you want to manually shut the fan off when the MPH timer is running, simply press the fan On/Off button. n Manual On/Off Fan Control Simply push the switch for manual on/off operation when immediate ventilation is needed. ADDITIONAL BENEFITS, 8 Amp max load Blue LED indicates when the fan is on For indoor use in a single gang box Includes matching wall plate May be used to comply with ASHRAE 62.2, LEED and ENERGY STAR 3.0 2 year limited warranty Preset Countdown Fan Timer On/Off FV-WCD01-W (White), FV-WCD01-A (Light Almond) On/Off/Light FV-WCD02-W (White), FV-WCD02-A (Light Almond) Minutes Per Hour (MPH) Fan Timer Timer and Sensor Settings Preset Countdown and Hourly Timer FV-WCD01-W/A FV-WCD02-W/A ing ing Blue LED Light Blue LED Light Amperage Maximum Fan Load 8 Amp 8 Amp Dry Contact Switching 24V AC input/output 24V AC input/output Max. Fluorescent Light Load N/A 400 Watt Termination 6" Leads 6" Leads Standard Certifications

Panasonic EcoSwitch line of products provide commercial grade quality at residential grade pricing. EcoSwitch 1 Function Switch On/Off Ideal for Fan Fan On/Off Switch Back and side wiring terminals accept both solid and stranded wire to ease installation Full-rated current capacity with fluorescent or resistive loads. Motor capacity is 80% of switch rating Fits single gang box / Includes matching wall plate FV-WCSW11-W (White) FV-WCSW11-A (Light Almond) Amperage FV-WCSW11-W/A ing Single Pole Quickwire Push-in, and Side Connection 2 Function Switch On/Off Ideal for Fan/Light Multi-switch combination devices save space and add convenience Common feed shunted internally to all switches Elegant decorator styling provides multiple controls in a single-gang wall box Fits single gang box / Includes matching wall plate FV-WCSW21-W (White) FV-WCSW21-A (Light Almond) Amperage FV-WCSW21-W/A ing Single Pole / Single Pole Side Connection

EcoSwitch is available in single, double, triple and quad functions to provide a complete package for all of your residential and commercial application needs. 3 Function Switch On-Off Ideal for Fan/Light/Night-light Multi-switch combination devices save space and add convenience Common feed shunted internally to all switches Elegant decorator styling provides multiple controls in a single-gang wall box Fits single gang box / Includes matching wall plate FV-WCSW31-W (White) FV-WCSW31-A (Light Almond) Amperage FV-WCSW31-W/A ing Single Pole / Single Pole / Single Pole Quickwire Push-In, and Side Connection 4 Function Switch Designed for model FV-11VHL2 Heat/Fan/Light/Night-Light Single pole/double throw on-off-on top switch, two single pole on-off switches Multi-switch combination devices save space and add convenience Common feed shunted internally to all switches Elegant decorator styling provides multiple controls in a single-gang wall box Includes matching wall plate FV-WCSW41-W (White) Individual Switch Amperage Total Switch Amperage FV-WCSW41-W ing Single pole / double throw on-off-on top switch, two single pole on-off switches 20 Amp Quickwire and wire leads

Cross Reference for Applicable WhisperControl & EcoSwitch to Panasonic Fans Model FV-WCCS1-W/A FV-WCCS2-W/A FV-WCDO1-W/A FV-WCD02-W/A FV-WCSW11-W/A FV-WCSW21-W/A FV-WCSW31-W/A FV-WCSW41-W Switch Type Condensation Sensor On/Off Condensation Sensor On/Off/Light Countdown & Hourly Timer Countdown & Hourly Timer FV-05-11VK1 X X X FV-11-15VK1 X X X 1 Function Control 2 Function Control 3 Function Control 4 Function Control WhisperGreen Select FV-05-11VKS1 X X X FV-05-11VKL1 X X X FV-11-15VKL1 X X X FV-05-11VKSL1 X X** WhisperRecessed/ Recessed LED FV-08VRL1 X X FV-08VRE1 X X FV-05VQ5 X X X FV-08VQ5 X X X FV-11VQ5 X X X FV-15VQ5 X X X WhisperCeiling FV-20VQ3 X X X FV-30VQ3 X X X FV-40VQ3 X X X FV-08VQL6 X X X X FV-11VQL6 X X X X FV-15VQL6 X X X X WhisperSense Lite FV-08VQCL6 X X** FV-11VQCL6 X X** FV-08VF2 X X X FV-11VF2 X X X WhisperFit FV-05VFL4 X X X X FV-08VFL4 X X X X FV-11VFL4 X X X X FV-05VS3 X X X FV-08VS3 X X X WhisperValue FV-10VS3 X X X FV-08VSL3 X X X X FV-10VSL3 X X X X EcoVent WhisperSupply Wall FV-07VBA1 X X X FV-07VBB1 X X X FV-01WS2 X X X FV-04WS2 X X WhisperWall FV-08WQ1 X X X WhisperWarm FV-11VH2* X* X* FV-11VHL2* X* X X* FV-10NLF1 X X X WhisperLine FV-20NLF1 X X X FV-30NLF1 X X X FV-40NLF1 X X X WhisperComfort FV-04VE1 X WhisperWelcome, WhisperSense, and WhisperGreen Select S/M models are not compatible with the above switches. *Needs 1 control per function; **Switch is for light and night-light only. Panasonic Eco Solutions of North America Eco Products Division Two Riverfront Plaza Newark, NJ 07102 us.panasonic.com/ventfans For Order Information PHONE: 866-292-7299 FAX: 888-553-0723 ventfans@us.panasonic.com Design and specifications subject to change without notice. VF151307SS