GE Security. How to Upgrade from InfoGraphics to Facility Commander Wnx FAQ

Similar documents
Facility Commander Wnx

Integrated security management platform for Windows. Seamless. Effective. Efficient.

Architectural and Engineering Specification for a Security Management System. StarNet 2

Facility Commander Complete, Integrated Command and Control

GE Security. Wnx. Facility Commander. Integrated security management platform for Windows. Seamless. Effective. Efficient.

Access Professional Edition. The flexible access control system that grows with your business.

AC2000 Security Hub Security and Event Management System

ARCHITECTURAL AND ENGINEERING SPECIFICATION

Tech Data Sheet D01662GB0_Esgraf 4.1 and Configuration Server 30/2011 2/(5)

PotterNet Fire & Facility Supervising Station

Access Control for. Part 3 of 4. Brought to You by. Presented by Video Security Consultants

GMS GRAPHICAL MANAGEMENT SYSTEM

Access CONTROL. MANAGEMENT Software

Complexity made simple

HikCentral Web Client. User Manual

HikCentral Web Client. User Manual

CompleteView Alarm Client User Manual. CompleteView Version 4.6.1

UD-VMS510i. Surveillance Management Center

by Honeywell WINMAG THE ULTIMATE VIGILON TEXT AND GRAPHICS SOFTWARE

OpenDevice Events Guide

Product Datasheet MM8000 MP3.10 Management Station

Vykon. Security. Integrated Access Control. Web enabled security management built on the Niagara Framework

Patriot Systems Limited

Datasheet Crowd Management

ONYXWORKS AND FIRSTVISION. Version 4

DVTEL DVR Interface. DigiOp DVR Interface

The system should also be capable of recording events automatically on any compatible DVR and should be able to retrieve recordings based on events.

Cardax System Comparison

Course Catalogue. An evolution of excellence. Welcome to the UTC Fire and Security EMEA Lenel OnGuard Training Catalogue for Value Added Resellers

System Galaxy Quick Guide

Product Datasheet MM8000 MP3.15 Management Station

HikCentral Specification. HikCentral V1.1.1 Specification

Building Integration System. Your platform for customized security and safety management.

Datasheet. Version 3.8. License Plate Recognition + Red Light Violation Detection. Datasheet LPR + RLVD Version

Datasheet Face Recognition [Genetec VMS]

Supervisor Standard Edition

Gallagher System Integrations

D-Link Central Management System

RFP Addendum 2 March 31, 2016

P2000 and Metasys System Integration

Am I safe working in this building?

Before you install ProSeries Express Edition software for network use

Milestone XProtect. Central 3.7 User s Manual

Digital Video Solutions

This technical update applies to Pro-Watch Software Release 3.5 and later.

FALCO Access Control. Product Training

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM. ENGINEERING SPECIFICATION INTELLIGENT REPORTING FIRE DETECTION SYSTEM February 2017

HWIN CCTV Camera Control Application

Instruction manual MTL process alarm equipment. October 2016 CSM 725B rev 2 MTL RTK 725B. Configuration Software Manual

Pro-Watch Software Suite. Architect and Engineering Specifications. January 9, 2002 Revision 3.4

MegaPower CPU ADMPCPU

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Ademco Vista Alarm Panel

ENTERPRISE. Sales Guide ACCESS CONTROL SYSTEM.

BIS - Overview and basic package

Desigo CC Building Automation and Fire Safety FAQs

Innovative protection that combines power and flexibility

P2000 Security Management System Express Edition Version 3.14 SP5

Before you install ProSeries software for network use

Industrial Security Capabilities. Honeywell Proprietary

TrueAlarm Fire Alarm Systems

Milestone SMI Intrepid II Perimeter Module 1.1 User s Manual

BMS Specification. Lonix Ltd.

TrueAlarm Fire Alarm Systems

Pro-Watch Facility Manager

Patriot Systems Limited

EnergyMaster. ENEC Monitoring System. An on-site supervision and remote monitoring solution

Avigilon Control Center 5 System Integration Guide

LYNX CE CENTRAL CONTROL FOR OSMAC. General Specifications

DIAMOND II. DARM Delayed Alarm Reporting/Masking. Manual Number AV Revision - A.1 September 3, 2004

Recording Server PRELOADED

System Description AutroMaster V Presentation System

Complete solutions for commercial security. Verex delivers leading intrusion, access and video products to protect today s companies

LSM MANUAL PRINCIPLES OF LSM

Security Escort Central Console Software SE2000 Series

GE Security SAPPHIRE Pro

BOSCH GV4 Alarm Panel

LYNX SE CENTRAL CONTROL FOR NETWORK GDC. General Specifications

BlackBerry AtHoc Networked Crisis Communication Siemens Indoor Fire Panel Installation and Configuration Guide Release Version 7.

The IPPS was developed on IBM-PC platform under QNX real time operating system (RTOS) and uses QNX-Windows GUI.

Millenium Electronic Access Control Systems Networked Real-Time Access Control

Centroid Snet 2. Battery Management Software. User Manual V1.1. Eagle Eye Power Solutions, LLC Keeping an Eye on Your Critical Power!

P2000 and Metasys System Integration

KELTRON LS 7000 ALARM MANAGEMENT SYSTEM Keltron Alarm Monitoring, Dispatch, and Reporting Software

Designing the Right Access Control System A Case Study. 12 th May 2010

Aviation Solutions. Why Tyco for airports? Our systems help protect over 110 airports. Secures over 80% of UK Airports and more than 60 US Airports

Using ANM Mobile CHAPTER

MICROPOINT to MICROPOINT II UPGRADE

Before you install ProSeries software for network use

Avigilon Control Center System Integration Guide

ONYX FirstVision Specification Interactive Firefighters Display

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Datasheet Video Based Fire & Smoke Detection

Grandstream Networks, Inc. GDS3710 Input/output Connection Guide

Rosenberger Intergrated Operation and Maintenance Center for all repeaters(2g/3g/lte) following CMCC and TMN specification.

Avigilon Control Center System Integration Guide

Alarm Client. Installation and User Guide. NEC NEC Corporation. May 2009 NDA-30364, Revision 9

Secure Your Way of Life. Now Compa ble With. Climax Home Portal Platform. Enable a Connected Future

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

TrueAlarm Fire Alarm Systems

Transcription:

GE Security How to Upgrade from InfoGraphics to Facility Commander Wnx FAQ GE Security Proprietary Page 1 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

GE Security remains committed to the sales and support of its current Windows-based access control and integrated security management platforms, continuing to protect its customer s hardware investments with the added benefit of software upgrade compatibility to a next-generation technology platform Facility Commander Wnx. The Facility Commander Wnx Edition platform represents a convergence of our current Windows based software front-ends including Secure Perfect, Diamond, Sapphire Pro, and Facility Commander s cross-platform integration technology. This strategic initiative will provide GE Security the ability to better serve the needs of its customers through a single unified software platform moving forward. The release of Facility Commander Wnx v7.5 will introduce the first phase of InfoGraphics ACU controller support, providing our customers a new Microsoft Windows based front-end replacement for their existing Sapphire Pro and Diamond access control systems. Facility Commander Wnx is available through exclusively authorized and factory trained GE Security channel partners. GE Security offers regularly scheduled Facility Commander Wnx training classes at its headquarters in Bradenton, FL and other regional locations around the country. The class covers system installation, configuration, administration, and operations. Visit the GE Security website for specific information on training class registration fees and location availability. Customers that have their Sapphire Pro or Diamond systems covered under an active System Support Agreement (SSA) are entitled to receiving a Facility Commander Wnx software upgrade equivalent to their previously purchased system licensing at no charge. Customers that do not have their Sapphire Pro or Diamond systems under an active SSA can purchase a Facility Commander Wnx software upgrade. The software upgrade purchase provides trade-in credit value and includes software equivalent to their previously purchased system licensing as well as 12-Month SSA coverage. Please contact the GE Security Applications Engineering Pre-Sales Support Team in Boca Raton, FL to request assistance with evaluating and planning customer upgrades. The balance of this document will provide specific requirements, expected procedures, and general recommendations for a successful upgrade and migration to Facility Commander Wnx. GE Security technical services can be contracted for assistance with any aspect of a customers upgrade and migration plan. An overall upgrade and migration plan consists of 3 phases: System Configuration Evaluation & Budget Planning Analyze a customer s current system deployment, software version, license capacities & options, and ACU hardware versions to determine applicability and compatibility with the initial release of FCWnx v7.5. Identify if any custom interfaces, reports, and/or GE Security Enterprise Consulting Services are needed above and beyond any on-site technical support assistance with executing the migration and upgrade. Pre-Migration Upgrade Preparation Prepare the customer s current system by upgrading any software, ACU controller hardware an/or firmware versions to the minimum requirements specified in this document. This can be done at any time prior to the upgrade and migration to FCWnx. System Upgrade & Migration Plan, schedule, and execute the system upgrade and migration. It is recommended that customer training be performed prior to executing the actual upgrade and migration on-site. Q: How can I pre-qualify my system for compatibility with the initial FCWnx v7.5 release feature set to make sure it meets my needs? A: The GE Security Applications Engineering Pre-Sales Support Team will assist you with prequalification, recommendations, and planning. A system evaluation utility will be used to analyze GE Security Proprietary Page 2 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

your current system configuration and utilized feature set. A gap analysis report will be produced and reviewed with you to determine compatibility and what upgrade options may be appropriate. Q: What version does my GE Security InfoGraphics system need to be at for upgrade compatibility and migration to FCWnx? A: Systems should be updated to the following software versions for upgrade compatibility prior to performing a database conversion and migrating to FCWnx: Diamond I version 8.11.a7 Diamond II version 2.3 SP3 Sapphire Pro version 4.75.03 FCWnx provides a database conversion utility that will prepare and convert the above Diamond II system version databases to the specific FCWnx format required. Data integrity is critical and validation of this process may need to be performed multiple times in advance to insure quality of the actual on-site conversion of the live production system just prior to migration switchover. The GE Security Technical Support department will offer an InfoGraphics System to FCWnx database conversion service for a flat fee for those customers who do not wish to perform this procedure on their own. Database backups on CD media can be submitted to GE Security and will be converted and validated to be FCWnx ready. The final converted and validated database will be returned on CD media. Q: Will my current GE Security InfoGraphics ACU Controllers work with FCWnx? A: ACU Controllers supported are those manufactured and shipped since approximately 2000 and are of surface mount technology, Motorola ColdFire processor based, 16MB RAM, FLASH memory, and capable of running v3.0 firmware or higher. These supported characteristics are found in the following models: ACUX, ACUXL, and ACURS Series Downstream RRE, RIM, RRM, and IKE peripherals are compatible To verify if your existing ACU controllers will be compatible with FCWnx, you can produce a Panel Status Report from your Sapphire Pro or Diamond system that provides Standard and PROM information details for each ACU. You can generate this report from Main Menu > Status/CTRL > Panel Status. This information should be submitted to the GE Security Applications Engineering Pre- Sales Support Team in Boca Raton, FL for review and validation. If any ACU controller is identified as not having upgrade compatibility, it is more than likely an older generation ACU2 series PCB assembly that will need to be replaced. This can be easily accomplished by ordering a new ACUXL PCB assembly (Part Number ACU-XL16B) and performing an ACU2 PCB assembly replacement as described in the Replacing ACU2 PCB Assembly.PDF document. In preparing for this upgrade and migration to FCWnx, it is recommended wherever possible, that any head of line ACU controllers that are connected to an InfoGraphics system server via serial communications be switched to LAN connectivity. This will provide increased benefits in performance and flexibility for distributed load balancing that can take advantage of the Com Client Redundancy for Device Hosting and Failover option available in FCWnx. GE Security Proprietary Page 3 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

Q: What are the computer requirements for Facility Commander Wnx? A: The table below shows the hardware, operating system, and database requirements for Facility Commander Wnx. In most cases, it is recommended to implement a new server for Facility Commander Wnx, as to provide a progressive migration from an InfoGraphics system to FCWnx in a live production environment. Customers will want to retain their InfoGraphics system server for reporting against database history and archives prior to the migration. Specifications Minimum Recommended OS & DB Support Professional Edition Server Intel P4 2GHz CPU 1024x768 16bit color 1 x 2.XGHZ CPU / Quad Cores 4 GB RAM 1024x768 32bit color Win XP Pro SP3 Vista SQL 2008 express Clients Enterprise & Global Edition Server Clients Intel P4 2GHz CPU 1024x768 16bit color Intel P4 2GHz CPU 10/100 NIC CDROM 1024x768 16bit color Intel P4 2GHz CPU 1024x768 16bit color Raid 1 1 x 2.XGHZ CPU / Dual Cores 1024x768 32bit color 1 x 2.XGHZ CPU / Quad Cores 4 GB RAM CDROM 1024x768 32bit color RAID 1 or 10 1 x 2.XGHZ CPU / Dual Cores 1024x768 32bit color Win 2003 Server R2 SQL 2005 Server SP1 Or Win 2003 Server R2 SQL 2008 Or Win 2008 SQL 2008 Win XP Pro SP3 Vista NOTES: Servers should be equipped with an appropriate backup media device such as CDRW, Tape, or network accessible storage. A routine backup plan should include the FCWnx SQL Server database and the full contents of the GE/FCWnx folder under program files. All Global Edition deployments should have the same versions of operating system and SQL at each server. Integrated Digital Video Surveillance can be CPU and memory intensive. Workstations intended for real-time alarm & event driven video management should exceed recommended client specifications. For video intensive operations, workstations with Dual Processors (Each with Dual or Quad Cores), 4GB System RAM, and 128MB Multi-Monitor Video Cards are recommended. GE Security Proprietary Page 4 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

Q: What are the actual upgrade procedures that will need to be performed once I have satisfied the main pre-migration upgrade requirements? A: Step by step instructions are detailed in Chapter 5 of 460645001 FCWnx v7.5 Upgrade Manual. PDF. The general procedural steps are: 1. Update customer s current Sapphire Pro or Diamond system software and ACU hardware to minimum requirements and perform pre-conversion preparations 2. ACU controller communications are recommended to be converted over to direct LAN onboard for maximum benefit of FCWnx hosting and failover capabilities 3. Install new FCWnx Server(s) and Clients on LAN and license system appropriately, validate network connectivity OK in Workgroup or Domain deployment 4. Convert Database on FCWnx server, perform any necessary manual programming for items not covered under the conversion utility which you have previously noted 5. Take ACUs off-line in Sapphire Pro or Diamond, bring them on-line in FCWnx from Controller Monitor 6. Confirm all is OK, turn on FCWnx ACU protocol lock 7. Retain access to Sapphire/Diamond server for history reporting as needed Q: What database records, files, or other items are NOT converted from an InfoGraphics system under the database conversion utility process? A: Items that are NOT converted: 1. Permissions for the various Operators will need to be reset. 2. Badge designs Will need to be recreated with the new FCWnx Photo ID Credentialing option, which includes a fully featured Credential Designer application. 3. Graphics maps and icons will need to be recreated and imported with the new FCWnx Graphics Monitoring and Control package, which includes a fully featured Map & Symbol Editor application. Graphics maps must be in JPG, GIF, PNG, or AutoCAD DXF R12 format before they can be recreated and imported into FCWnx. WMF, EMF, and ICO image formats are not natively supported. 4. Reports FCWnx provides standard reports that are applicably equivalent to those found in your InfoGraphics system. Any additional or custom reports above and beyond those provided with FCWnx will need to be recreated. 5. Serial CCTV Switcher configuration & alarm assignments will require reprogramming 6. Global Alarm Masking functions will require to be re-associated with applicable record relationships 7. Global Remote Control functions will require to be re-associated with applicable record relationships 8. History Archive data is not converted and shall remain accessible only on your InfoGraphics system server GE Security Proprietary Page 5 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

Q: What are the InfoGraphics system features NOT supported in the initial FCWnx v7.5 release? A: FCWnx provides a broad range of enhanced capabilities, new features, and implementation concepts that are equivalent for achieving the majority, if not all, of your InfoGraphics system functions in the initial FCWnx v7.5 release. The following table identifies specific features and options that are not natively supported in the FCWnx v7.5 release. GE Security will continue to invest and develop future releases of the FCWnx platform and our customers can expect many of these features to be available in equivalent form as they apply to current market requirements. CAPABILITIES Sapphire Pro Diamond I Diamond II FC Wnx STANDARD FEATURES Area Loading - Occupancy Control Monitor Counting & Restriction No Area Loading - Real Time Muster Control Monitor No No No Two Person Rule - Personnel Classification & Presence Control No Two Person Keypad Alarm Masking No No Temporary Card Enrollment Reader Activation No Operator Login Scheduled Effective/Expiration Date Control No No No Employee/Visitor Screen Designer No No No GARC Access Event No No No STANDARD OPTIONS Guard Tour No Monitor Point Verification - Maint walk test monitoring & reporting No Host Upload Text File Utility EFI Utility System Interface - Paging Visiplex No DII Cardholder API No No No System Interface - Intercom Stentofon No No Alarm Interface - Radionics D6500 / D6600 No No LEGACY & CUSTOM SPECIALS NOT COMMERCIALYY AVAILABLE System Interface - Oasis No No System Interface - Bio Reader Portal Control No No System Interface - SCADA/MODBUS No No No System Interface - Computer Aided Dispatch Server No No No System Interface - Siemens Apogee No Alarm Interface - Siemens MXL Fire Panel No Alarm Interface - Simplex Fire Panel No No Alarm Interface - Intrepid Perimeter Fence Detection No No No Alarm Interface - FIBERSENSYS No No No Alarm Interface - Anti Loiter System No No No Alarm Interface - Digitize No No No Video DVR - Invision No Video DVR - Intellex No No, v3.1 Video DVR - NICE No No, v8.0 (SEQ) AUTOMATIC CARD NUMBER SEQUENCING No No (INCIL) AUTOMATIC INCREMENT ISSUE LEVEL No No No (UNV ) CUSTOM SPECIAL No No No (WDW) DURESS PIN CUSTOM SPECIAL No No No GE Security Proprietary Page 6 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

Q: What are the FCWnx v7.5 upgrade benefits and platform capabilities I should be presenting to my InfoGraphics customers to aid in their decision making process? A: FCWnx provides a broad range of enhanced capabilities, new features, and platform deployment options that are summarized in the following table: Why Upgrade? from Sapphire / Diamond to Facility Commander Wnx GUI Usability Look and feel HTML / Menu application lists Windows XP / Office application groups Desktop application window management Multi-application admin & monitoring, single window Multi-application admin & monitoring, multi-window, multi-monitor desktop desktop Integrated Digital Video Surveillance Video driver support GE DVMRe CD, CT, CT-II Series GE DVMRe CD, CT, CT-II Series GE StoreSafe Pro, Pro-II Series GE StoreSafe Pro, Pro-II Series GE SymDec, SymSafe/Pro Series GE SymNet-1, Legend IP Dome GE VisioWave Discovery 300,12XX,24XX (v4.1) GE VisioWave Evolution 28XX,30XX (v4.1) AD Intellex DVMS8000 (v3.1) Pelco DX8000 (v1.0) Panasonic WJ-HD500A (v2.5) Integral DVXi (v3.1, v4.0, v4.1) Integral DS Xpress (v2.1) NiceVision Harmony (v8.0) NiceVision Pro (v8.0) Digital Watchdog DW-Pro (v2.3) Video Device Tree Navigation with camera drag & No drop User definable, multi-camera custom views No Unlimited Multi-camera video management and viewing Multi 1-UPs only Multi 1-UP, 2-UP, 4-UP, 9-UP, 16-UP, Custom 7-UP, Custom 11-UP, Custom Center/Perimeter Quick recall video playback on any camera view No Easy right mouse click navigation: Last 15sec, 30sec, 1min, 2min, 5min or last 3 events Auto pop-up live video view on alarm Multi 1-Ups only Configurable for multi-camera views in single window replac e or multi-window continuous Create and save video clips to file Limited From playback of multi-recorded and live video streams simultaneously Graphics Monitoring & Control Graphics Map Preferences Editor No Multi-layer CAD import, create, edit, viewing No Map import file formats.emf. JPG,.GIF,.PNG and AutoCAD.DXF R12 Full design tool palette with drawing, image import, No text, and hyperlink control of DB device objects Device symbol editor and library for quick drag and drop icons, precision placement with nudge No, Fixed Icon Library GE Security Proprietary Page 7 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

Dynamic multi-state device symbols Static symbol tri-state (Alarm, Reset, Trouble) Dynamic multi-state, all states user configurable per device symbol Device symbol import file formats Dedicated Icons. JPG,.GIF, Animated.GIF,.PNG Multi-map navigation management and viewing Single window, multi-map drill down, single layer view at a Multi-window, multi-map drill down, multi-layer view time Map navigation tree hierarchy by facility with realtime status Limited Real-time device status for alarm and non alarm conditions Device command & control Fully scalable map views and icons with zoom control Limited External Integration Capability API for Device Command & Control, Status, and No External Alarm Processing Open SQL Database Customizable web based report server NEW v7.5 Application Features Automatic credential deactivation based on duration of inactivity policy Threat Level Access change hierarchy of personnel access per controller(s), manual operation or via global event triggers from controller(s) alarm input(s) Alarm Category user definable classification of alarm records for augmenting alarm monitor assessment Alarm Lock Down Change PXNplus based controller(s) operational mode based on local alarm input(s) via global event triggers Local Keypad Extended Unlock/Shunt PXNplus controller supported reader keypad extended unlock command with local shunt & pre-alarm annunciation New External Reports Who Has Access and Reader Where When report for easy auditing ACU based controller Security Area & Access Rights Management Alarm states only Limited to Door lock/unlock, Alarm Masking and Relay operations All alarm, event, and conditional states simultaneously All device dependent commands with state change confirmation, Extended No, DII limited to Cardholder API Documented table access & Stored Procedures for provisioning of Personnel and Credential data with automatic controller updates Limited Crystal Reports (DII Crystal Reports Server 2008 Support only) DII only No NA NA No Individual records configured separately across multiple forms NLS Language Packs Arabic No Dutch No French No Italian No Japanese No Korean No for M-Series & DirecDoor, planned for new PXNplus based ACU series for M-Series & DirecDoor, planned for new PXNplus based ACU series Simplified AREA and ACCESS RIGHTS forms for easy configuration and assignments GE Security Proprietary Page 8 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009

Portugese No Russian No Simplified Chinese No Spanish No Traditional Chinese No Turkish No Operating System & Database Windows Vista support Windows Server 2008 No SQL Server 2008 Express No SQL Server 2008, local or remote DB inst. No SQL Server Cluster, remote DB inst. No 32 & 64 Bit Server environment support No For specific feature support and additional FCWnx platform capabilities of benefit to InfoGraphics Sapphire/Diamond system customers, please refer to Facility Commander Wnx system data sheets GE Security Proprietary Page 9 of 9 IGS to FCWnx Upgrade FAQ APRIL 2009