COMMON WORK RESULTS FOR ELECTRICAL: Basic Electrical Materials Methods

Similar documents
SECTION ELECTRICAL GENERAL PROVISIONS

MEDIUM, LOW AND CONTROL VOLTAGE CABLES

PART GENERAL 1.01 SECTION INCLUDES

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (600 VOLTS AND BELOW)

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION P01 LIGHTING AND APPLIANCE PANELBOARDS - A-SERIES

M001. Revenue Services ISSUED FOR CONSTRUCTION SEPTEMBER. 2, East State Parkway Schaumburg, Illinois Do Not Scale Drawings

SECTION PANELBOARDS Painting Wire and Cable Overcurrent Protective Devices.

SECTION PANELBOARDS. A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section.

DIVISION 16 ELECTRICAL

Brown University Revised June 29, 2012 Facilities Design & Construction Standards SECTION ELECTRICAL DESIGN CRITERIA

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

occurs and be cause for termination of the contract.

Element D Services Electrical

A. Connected to the equipment ground B. Bonded to the box C. Connected to nearest water pipe D. Connected to a ground rod

A. Shop Drawing submittals shall include, but not be limited to, the following:

SECTION BASIC ELECTRICAL MATERIALS AND METHODS. A. This Section includes basic electrical materials and methods including:

Where technical minds provide innovative solutions

SECTION AUTOMATIC TRANSFER SWITCHES PART 1 - GENERAL

All surfaces shall be restored where surface finish damage is evident. Physical material damage will require replacement of part.

A. Product Data: For each electrical identification product indicated. B. Comply with 29 CFR and 29 CFR

PANELBOARDS & BUILDING DISTRIBUTION

CHAPTER 20 SERVICE EQUIPMENT

SECTION (16075) - IDENTIFICATION FOR ELECTRICAL SYSTEMS

SECTION GENERAL-SERVICE COMPRESSED-AIR SYSTEMS

FIRE ALARM: BY OTHERS, IF REQUIRED.

MN/DOT SPECIFICATION FOR A ROADWAY LIGHTING SERVICE CABINET

Informational Bulletin on Mobile office Units Prepared by Mark Hilbert May 17, 2017

SECTION (15900) - INSTRUMENTATION AND CONTROL FOR HVAC

FIRE ALARM: BY OTHERS, IF REQUIRED.

1. Distribution panelboards. 2. Lighting and appliance branch-circuit panelboards. 3. Load centers.

SECTION (15767) - UNIT HEATERS

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

Electricity Unit Notes. Agriculture Mechanics I

SECTION ISOLATED POWER SYSTEMS

SECTION ELECTRICAL IDENTIFICATION

SECTION (16140) - WIRING DEVICES

PHILADELPHIA REGIONAL PORT AUTHORITY VOLUME 2 SPECIFICATIONS FOR VEHICLE PROCESSING FACILITY NAVAL BUSINESS CENTER PHILADELPHIA PA.

APPENDIX - L INTERNATIONAL RESIDENTIAL CODE ELECTRICAL

SECTION C. Section Cable Trays for Electrical Systems: Additional identification requirements for cable tray systems.

GENERAL SPECIFICATION ELECTRICAL

SECTION AUTOMATIC TRANSFER SWITCHES

Installation Instructions

Allegany College of Maryland ACM Welcome Center M&D Project No

ORDINANCE NO

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Section Electical General Provision

Division 26 ELECTRICAL TABLE OF CONTENTS

NATIONAL ELECTRICAL CODE (NEC) & NFPA 70E ARC FLASH ELECTRICAL SAFETY

Incorporate as part of the Contract Documents, the following:

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

CORFLEX TYPE MC-HL POWER, CONTROL & INSTRUMENTATION CABLES

HMC ARCHITECTS 2495 Natomas Park Drive, Studio 100 Sacramento, California ADDENDUM NO. 3

ONE- AND TWO-FAMILY DWELLING ELECTRICAL CODE HANDOUT (2015 Michigan Residential Code Effective February 8, 2016)

SECTION LOW VOLTAGE LIGHTING CONTROLS

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

SECTION FAN COIL UNITS

B. Shop Drawings: List of legends and description of materials and process used for premarking wall plates.

1.1 Refer to Section for General Mechanical Requirements. 1.3 Refer to Section for Pipe and Equipment Identification Requirements.

SECTION STEAM CONDENSATE PUMPS

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Permit Fairview Municipal Building 55 Anderson Ave. Fairview NJ Issue December 31, 2015

B. Configuration of system shall be through Schneider Electric in Homewood, Illinois (Jerry Lanfear ).

SCHOOL DISTRICT PALM BEACH COUNTY BUILDING DEPARTMENT PLAN REVIEW CHECK LIST -- ELECTRICAL

Student Services & Classroom Addition. A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

IDENTIFICATION FOR ELECTRICAL SYSTEMS July Electrical Systems

LIVELIFE.TRAVELWELL. DesignStandardsManual Electrical DenverInterna onalairport AirportInfrastructureManagement

CORFLEX. TYPE MC-HL & MV-105 or MC-HL OIL & GAS CABLES

SECTION LOW VOLTAGE POWER PANELBOARDS - SPECTRA

Chapter 1 General... 5

Page 1 of General

ALL ENGINEER NOTES SHALL BE DELETED FROM THE FILE OR MARKED AS HIDDEN. DIVISION 16 ELECTRICAL SECTION 16010

SECTION DOMESTIC WATER HEATERS

National Electrical Code

On-Call General Contractor Specifications University of Maryland College Park June 2013

Brasch Hazardous Location Unit Heaters

Installation Instructions

IEC and NCCER Mapping for Year 1

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 11/06/2018

SECTION COMPRESSED AIR SYSTEM. A. Pipe and pipe fittings, including valves, unions and couplings.

A. Section includes distribution panelboards and lighting and appliance branch-circuit panelboards.

Renovate MCRC Facilities Great Lakes, IL

INSTALLATION OF ACCESS FLOOR SYSTEMS IN GENERAL OFFICE AREA AND COMPUTER ROOM

SECTION EXTERIOR LIGHTING

DIVISION 16 BASIC MATERIALS, METHODS, AND REQUIREMENTS SECTION 16A-1

Copy Right By: Thomas T.S. Wan

University of Illinois at Urbana-Champaign Small Homes Council-Building Research Council COUNCIL NOTES G4.2 ELECTRICAL WIRING

Technical Specifications Project No Fire Station Number 8 NO TEXT THIS PAGE

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

Spring Test 6 due 04/26/2013

AFC Cable Systems: the Cable Industry Leader for Over 80 Years

SECTION LIGHTING CONTROLS

POWER AND CONTROL PRODUCTS QUICK RESPONSE PROGRAM.

Sundance Spas SPA EQUIPMENT SYSTEM. Installation Instructions. P/N Rev. A

XP Series Non-Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof

SECTION SPECIAL PROVISIONS FOR ELECTRICAL WORK

Flame Retardant EP/CPE POWER, CONTROL & INSTRUMENTATION CABLES

DESIGN AND CONSTRUCTION STANDARDS SPECIFICATION GUIDELINES

SECTION BASIC ELECTRICAL MATERIALS AND METHODS

Transcription:

1. BASIC ELECTRICAL MATERIALS 1. All conduit and raceway must be 3/4" or larger. Exposed raceway in finished areas shall be in 700 or larger wiremold. Exception: runs to individual devices 10 or less, ½ may be used. 2. All wiring shall be 98% conductivity copper. 3. All buss and buss duct conductors shall be 98% conductivity tin plated copper. 4. Aluminum or aluminum alloy connectors shall not be used on copper. 5. All wiring shall have THHN insulation minimum for installation in conduit. 6. All wiring devices shall be specification grade. 7. Wire size, #12 AWG minimum for power circuits. 8. Conductors #10 AWG and larger shall be stranded copper. 9. All driven ground rods shall be 5/8" X 8'-0" copperweld. 10. All panelboards shall have both neutral and ground bus separate. All panelboards shall use bolt-on breakers, only. 11. No plastic anchors are to be used to support electrical conduit and/or equipment. Use metallic expansion type anchors. Do not use lead anchors. No explosive type install anchors shall be used. 12. All utility markers required inside buildings, structures and facilities to identify exposed and concealed utilities, including electric, shall be provided in accordance with specification 02600D01. 13. All electrical equipment shall be UL listed for the application in which it is used. 14. All equipment and devices provided to meet this specification shall meet all applicable FCC requirements and restrictions. 15. Do not provide any devices which contain mercury unless there is not a mercury free device on the market which will perform the same function. 16 Rigid Conduit Rigid conduit shall be standard weight, mild steel pipe. The conduit shall receive a protective zinc coating both inside and outside by means of hot-dip galvanizing. Threads shall not have any coating which will reduce the conductivity of the joint. Couplings, bends, elbows, fittings, etc., shall be subject to the same requirements as for straight lengths. All conduit and fittings shall meet UL-8 and labeled accordingly. Rigid conduit shall be delivered with plastic protectors on the threads. 17. Electrical Metallic Tubing (EMT) Electrical metallic tubing (EMT) shall be cold rolled tubing with a zinc coating on the outside and zinc coating or a protective enamel coating on the inside. All EMT fittings shall be the steel compression type and meet the same requirements as EMT. All entries into boxes, cabinets, etc., shall have insulated throat and compression ring type connectors conforming to UL-514. All EMT shall meet UL-797 and be labeled accordingly. 18. Surface Metal Raceway Metal raceway shall be two piece type, base mounted with snap-on cover as manufactured by wiremold or equal. Raceway installation shall be in accordance with manufacturer s instructions using adapters and fittings specifically designed and manufactured for the raceway used. Methods Page 1 of 5

19. Flexible Conduit Flexible metallic conduit shall be constructed from flexibly or spirally wound electro-galvanized steel. Connections shall be by means of galvanized, malleable iron squeeze type fittings, or tomic twist-in type in sizes not exceeding 3/4" size. Liquid tight flexible metallic conduit shall be light gray in color. It shall have seal tight fittings and shall be equal to American Brass "Sealtite" Type UA. 20. Plastic Conduit Plastic conduit shall be high impact, high grade, self extinguishing polyvinyl chloride (PVC) schedule 40, 90 deg. C, U.L. rated. Material must have tensile strength of 7,000 psi at 73.4 deg. F., flexural strength of 11,000 psi and compressive strength of 8,000 psi. Conduit fitting and elbows shall have the same requirements as the conduit. Exception: Use schedule 80 PVC conduit when required by codes. 2. BASIC ELECTRICAL METHODS 1. General 1. All wiring shall be in 3/4" or larger conduit, wireway or raceway. 2. All conduit shall be concealed except in designated mechanical rooms or unless otherwise specified and shown on drawings approved in writing by the UK Project Manager. Conduits which are not concealed must be surface metal raceway unless otherwise noted in the written exception. 3. Firestop all penetrations in accordance with the current edition of the National Electric Code. 4 All conduit, wiremold and junction boxes must be painted to match existing surface except in mechanical rooms. 5. During construction, cover all equipment subject to mechanical damage or contamination in any way. 6. All metering is to be included in contract unless provided by local utility company. Each building is to be sub-metered individually. All metering to meet UK Standard 262713. 7. Standard mounting height of devices: Receptacles Light Switches Fire Alarm Manual Stations Fire Alarm Horns Thermostats 18" A.F.F. 48" A.F.F. 48" A.F.F. 84" A.F.F. 53" A.F.F. 8. All electrical panels shall be clearly labeled as to what circuit, electrical outlet, and/or room that each breaker feeds. 9. Corridor outlets shall be provided at a maximum 65 feet spacing for floor machines. The 120 volt receptacles shall each be individually protected by a 20 ampere breaker and GFI receptacle. Methods Page 2 of 5

10. All Fire Alarm, Security Alarm, Communications Equipment, Elevator Controllers, Life Safety (including emergency lights, exit lights and combination emergency\exit lights), Handicap Access, Mechanical and Electrical Room lights and receptacles, and other similar systems shall be supplied by emergency generator distribution panels. Note: Due to battery maintenance cost, do not provide battery backed up emergency and exit lighting on emergency generator power unless the University request this redundancy in specified areas. 11. Install mechanical identification to properly identify every system and its components. 12. All conduit, duct and raceway shall be installed in accordance with UK Standard 260533. 2. Grounding 1. A separate equipment ground wire shall be run continuous to all equipment and receptacles. The University does not recognize or accept the conduit ground as an equipment ground. Any ground required must be a properly sized wire or wires (insulated or uninsulated) from the buildings single point ground bus and running through all distribution panelboards and connecting to the equipment to be grounded. 2. All buildings shall have ground rods and ground planes to meet the requirements of the NEC and also the grounding requirements of equipment within the building. All main ground points shall be meggered. If more than 10 OHMS, additional ground rods shall be driven. Additional ground rods shall not be less than 6 ft. apart. If more than 25 OHMS, special care shall be used to obtain less then 10 OHMS. 3. Main service entrance conduit shall have grounding locknuts on one end. Meter shall be grounded to main service disconnect by a bare copper ground wire, sized to NEC. 4. Main service neutral shall be grounded at only one point (the main service disconnect) and that ground shall extend from the main water service entrance point before main water valve. Methods Page 3 of 5

3. Motors 1. This standard applies to all general duty motors provided, even those specified in all other divisions such as Div 15 where motors are provided with pumps, air handling units and similar equipment. 2. Provide power factor correction capacitors on induction motors of 10 H. P. or above to correct power factor to.91 or more. Provide a disconnect switch for each capacitor bank. 3. All 3 phase electric motors, (5 Hp. and larger), shall be protected against single phasing. 4. Efficiencies specified shall be according to US efficiency test protocol which is IEEE 112 Test Method B. 5. Efficiencies shall be stamped on the nameplate of the motor. 6. All general purpose motors shall be NEMA Premium efficiency as noted in tables 1 and 2 as follows: Table 1 Nominal Efficiencies For NEMA Premium Induction Motors Rated 600 Volts Or Less (Random Wound) Open Drip-Proof Totally Enclosed Fan-Cooled HP 6-pole 4-pole 2-pole 6-pole 4-pole 2-pole 1 82.5 85.5 77 82.5 85.5 77 1.5 86.5 86.5 84 87.5 86.5 84 2 87.5 86.5 85.5 88.5 86.5 85.5 3 88.5 89.5 85.5 89.5 89.5 86.5 5 89.5 89.5 86.5 89.5 89.5 88.5 7.5 90.2 91 88.5 91 91.7 89.5 10 91.7 91.7 89.5 91 91.7 90.2 15 91.7 93 90.2 91.7 92.4 91 20 92.4 93 91 91.7 93 91 25 93 93.6 91.7 93 93.6 91.7 30 93.6 94.1 91.7 93 93.6 91.7 40 94.1 94.1 92.4 94.1 94.1 92.4 50 94.1 94.5 93 94.1 94.5 93 60 94.5 95 93.6 94.5 95 93.6 75 94.5 95 93.6 94.5 95.4 93.6 100 95 95.4 93.6 95 95.4 94.1 125 95 95.4 94.1 95 95.4 95 150 95.4 95.8 94.1 95.8 95.8 95 200 95.4 95.8 95 95.8 96.2 95.4 250 95.4 95.8 95 95.8 96.2 95.8 300 95.4 95.8 95.4 95.8 96.2 95.8 350 95.4 95.8 95.4 95.8 96.2 95.8 400 95.8 95.8 95.8 95.8 96.2 95.8 450 96.2 96.2 95.8 95.8 96.2 95.8 500 96.2 96.2 95.8 95.8 96.2 95.8 Methods Page 4 of 5

Table 2 Nominal Efficiencies For NEMA Premium Induction Motors Rated Medium Volts 5kV or Less (Form Wound) Open Drip-Proof Totally Enclosed Fan-Cooled HP 6-pole 4-pole 2-pole 6-pole 4-pole 2-pole 250 95 95 94.5 95 95 95 300 95 95 94.5 95 95 95 350 95 95 94.5 95 95 95 400 95 95 94.5 95 95 95 450 95 95 94.5 95 95 95 500 95 95 94.5 95 95 95 4. Starter Disconnects Combination starter/disconnects must be equipped with a factory disconnect micro switch and this switch must be wired into control circuit to deenergize the starter before disconnect opens. 5. Computer and Computer Room Circuits 1. Power supply for computer systems shall be provided with an isolated ground wire back to the service entrance single point isolated grounding grid buss. 2. Main feeder routing for computer and telephone cabling shall be inside hinged wireway whenever possible, branching off to individual computer terminations with conduit. Wireway shall be sized for 50% future growth. Minimum wireway size shall be 6". 6. Communications 1. Communications electrical shall meet Standards Division 27. 2. Clocks and bells shall be self correcting compatible with the campus Primex Wireless system. 3. All television and telecable conduits shall have a home run to the floor communications panel. Outlets looped between rooms are not acceptable. 7. Security Systems Provide conduit from at least one or more entrance doors on each building wall to a common 6"x6"x4" junction box mounted above the door. Door frame must include a small J-Box on each side of frame for lock/unlock and hinge feed thru and a small J-Box on top of frame for magnetic switch contacts. Provide a minimum of 1 conduit from each door 6"x6"x4" J-Box to the building facility management system or the designated access control panel for the future addition of access control. Methods Page 5 of 5