FirstEnergy Program Overview

Similar documents
ENERGY STAR Qualified Homes

Supplement A- Improving Forced Air Heating Systems

wattsmart New Homes Contractor-Certified HVAC Quality Assurance (HVAC-QI)

Registration Number: Registration Date/Time: HERS Provider: CA Building Energy Efficiency Standards 2013 Residential Compliance June 2014

Home Performance Science

Moisture, Ventilation & Global Weirding NEHERS Webinar Series

DUCT LEAKAGE (Page 1 of 3)

LEED for Homes V4 Provisional Alternative Compliance Paths for the Canadian market March, 2017

The evil that men do lives after them; the good is oft interred with their bones.

In the past, contractors sized heating and cooling systems GETTING HVAC RIGHT

ENERGY STAR v3.0 HVAC Checklists

ENERGY STAR V2.5 & 3 Designed to Qualify AIA Annual Convention

Duct Leakage, Sealing & Testing

ENERGY STAR SUMMIT DECEMBER 6, 2006 ENERGY STAR INDOOR AIR PACKAGE

Home Performance Energy Audit Report

WHY IS BUILDING SCIENCE IMPORTANT?

CITY OF DANA POINT. COMMUNITY DEVELOPMENT, BUILDING AND SAFETY Golden Lantern, Suite 209 Dana Point, CA

Home Performance Energy Audit Report

RESNET HERS Rater Sample Test Questions 2

Effects of Kitchen Ventilation on Residential Dwellings

Home Performance Energy Audit Report

Controlling Indoor Humidity in High Performance Homes. Danny Gough, Energy Solutions, LP

Capt. Tim s s Duct Design Mythbusters. The bitterness of poor quality is remembered long after the sweetness of low price is forgotten!

Put the V back in HVAC

When Duct Sealing Kills HVAC Equipment and Efficiency

Ventilation. ASHRAE 62.2 COMPLIANCE How do we get there? Bruce Hagen ND Dept. of Commerce.

Address Account # Member # Equipment Specifications Quantity Rebate. ENERGY STAR Appliances

18. Mechanical Ventilation

Basic Building Science insights for Spray Foam, HVAC and Moisture

Model 8140 & 8141 Fresh Air Ventilator Installation and Operations Manual

Equipment Specifications and Required Information Quantity Rebate

Welcome. High Performance Mechanicals for Houses That Work. Energy Design Conference - Duluth, MN. February 21 st, 2018

The Art of Building Science

Ventilation for New Low-Rise Residential Buildings July 20, 2015

EARTH ADVANTAGE HVAC REQUIREMENTS

The House is a System: Building Science: A New Way

The Housing Assistance Council is a national nonprofit organization that helps build homes and communities

50% 80% 7 Years. Filter. Ventilation Solutions IAQ Canada. Ventilate. of our time is spend indoors. Limited warranty on motors

Massachusetts Energy Code Technical Support Initiative

WHOLE-HOUSE VENTILATION SYSTEMS

NAHB Green Home Building Guidelines. 3.1 Prerequisites. ResCheck. Energy Efficiency

Tech to Tech May 07 HRV s & ERV s

Indoor Environmental Quality

Choosing Heating and Cooling Systems

RESNET ANNUAL CONFERENCE FEBRUARY 17, ENERGY STAR for Homes: The Road Ahead

2016 BUILDING ENERGY EFFICIENCY STANDARDS RESIDENTIAL HVAC ALTERATIONS

Effect of Moisture on Building Systems!

Because all SPF-insulated homes are very tightly constructed,

HVAC for Raters & Inspectors

Indoor airplus. Better Environments Inside and Out

Consumer Features & Benefits of Energy Efficient Products

ENERGY & WATER EFFICIENCY: HOME ASSESSMENTS. Jim Riggins Monument, CO

Pro Eco-Energy. Home Assessment

BEST PRACTICE RECOMMENDATIONS

Uniform Dwelling Code 2017 Updates SPS 323

Understanding Ventilation in Hot Humid Climates by Joseph Lstiburek

Green Building Practice Summary 3/10/2011

SUPPORTING DOCUMENT RESIDENTIAL ENERGY CODE WORKSHEET (2015) EFFECTIVE JANUARY 1, 2017

An Introduction to Energy Efficient and Effective Whole-House Ventilation

2015 MECHANICAL CODE REQUIREMENTS

1 INNOVATION & INTEGRATION: Transforming the Energy Efficiency Market Buildings.Energy.gov

2019 Smart Energy Existing Homes Program Manual

UNDERSTANDING AND USING THE HVAC DESIGN REVIEW FORM

U.S. EPA ENERGY STAR Residential Program Kathy Diehl, ENERGY STAR Program Manager January 15, 2009

MAD-AIR 2016 Mechanical Air Distribution and Interacting Relationships. John Tooley Advanced Energy (919)

IAQ Details. Tips from the ENERGY STAR Indoor Air Package Specifications Guide (& Program Update)

TO THE FOR PRESCRIPTIVE COMPLIANCE OF FOR RESIDENTIAL ALTERATIONS

2009 Washington State Energy Code Residential Sections

The Unplanned Impacts On Houses By Powered Attic Ventilators

The V in HVAC: Mechanical Ventilation in ENERGY STAR Certified Homes

Residential Air Leakage (Blower Door) Testing for Florida Code Compliance

Design Guide. Ecosmart Mini Duct Trunk and Outlet Design Guide for HVP50, HVP90 and HVP100 Air Handlers P/N 14013A

Residential Heating and Cooling Loads

Home Energy Audit. 170 Security Circle Suite 104 Athens, GA

Evaluate your insulation. Look for a tag in the attic that shows the R-Values of insulation in the floors, walls and ceiling.

Applying ducted, split-ductless systems. in High-Performance Homes

Monty Anderson Construction Group Home Address: 3251 Great Oaks Boulevard Kissimmee, FL Certified: Score: 164

Energy Efficiency Practices for the Low- Income Population

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

WHAT S UNDER YOUR ROOF?

MECHANICAL VENTILATION

Residential Makeup Air Systems & Requirements

SAFETY AND INSTALLATION MANUAL MODEL 8100

Ventilation and Indoor Air Quality

Heat Recovery Ventilation

Basic Home Energy Audit

Illinois Home Weatherization Assistance Program - Field Standards Manual

HEAT RECOVERY VENTILATION For healthy, energy efficient ventilation

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Smart Energy Existing Homes Program Manual

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

SLAB ON GRADE CONSTRUCTION Meeting the MN Energy Code ( air tightness) for 2017 Energy Design Conference. By Mike D. Wilson Dakota Supply Group

WHAT S CHANGED WITH ANSI/RESNET/ICC STANDARD 380. Iain Walker, Residential Building Systems Group

INSTALLATION AND OPERATION MANUAL 90-Series

Residential HVAC System Design

DEHUMIDIFICATION: Ice Arena Application & Product Guide. Design, construct and operate to control indoor humidity in ice rinks

2006 Building Science Press All rights of reproduction in any form reserved.

2017 Home Rebates Guidelines

Why Doesn t My HVAC System Work?

Technical Standards for the Air Conditioning and Heat Pump Professional BPI STANDARDS

Transcription:

FirstEnergy Program Overview Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio utilities: after March 23, 2011 Met-Ed, Penelec, and Penn Power: after October 28, 2009 West Penn Power: after June 1, 2013 15% more efficient than 2009 IECC (or relevant code when permitted) ENERGY STAR certification 9

Overview of This Webinar Basic Concepts Symptoms of Leaky Ducts Benefits of Tight Ducts Duct Installation for ENERGY STAR v3.0 Duct Testing Requirements ENERGY STAR v3.0 credentialing for HVAC Review of FirstEnergy incentives and ENERGY STAR marketing resources

Duct Leakage Requirements Required By: IRC 2009 & 2012 IECC 2009 ENERGY STAR v3.0 IECC 2012 Post Construction Leakage to Outdoors Refers to IECC 8 cfm per 100ft 2 of CFA 4 cfm per 100ft 2 of CFA* Testing not Required Total Rater-measured Duct Leakage at Rough-In Air Handler Installed Section N1103.2 Refers to IECC 6 cfm per 100ft 2 of CFA 4 cfm per 100ft 2 of CFA* 4 cfm per 100ft 2 of CFA Total Duct Leakage at Rough In Air Handler Not-Installed Section N1103.2 Refers to IECC 4 cfm per 100ft 2 of CFA 4 cfm per 100ft 2 of CFA 3 cfm per 100ft 2 of CFA Total Rater-measured Duct Leakage at Final Air Handler Installed Section N1103.2 Refers to IECC 12 cfm per 100ft 2 of CFA 8 cfm per 100ft 2 of CFA* 4 cfm per 100ft2 of CFA Air Handler and all ducts in Conditioned Space Testing not Required Testing not Required Testing Required Testing not Required *ENERGY STAR v3.0 - Exception for homes with fully ducted returns from bedrooms

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 4. DUCT LEAKAGE 4.1 Total Rater-measured duct leakage 8 CFM25 per 100 sq. ft. of conditioned floor area 15,16 4.2 Rater -measured duct leakage to outdoors 4 CFM25 per 100 sq. ft. of conditioned floor area. 15, 16, 17

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 4. DUCT LEAKAGE - (Effective as of 6/10/2014) Will include a footnote For a home with a dedicated return in each bedroom (i.e., not a bedroom pressure-balancing feature leading to a central return), the total Rater-measured duct leakage is permitted to be 1.)The greater of 6 CFM25 per 100 sq. ft. of CFA or 60 CFM25 at rough-in or 2.) The greater of 12 CFM25 per 100 sq. ft. of CFA or 120 CFM25 at final.

Heat Loss/Gain ACCA Manual J Determines the buildings heat loss/gain characteristics.

Equipment Sizing ACCA Manual S Relies on the Manual J load calculations to correctly size equipment. Basics of Sizing Heating sized from 100% to 140% of design loads or next nominal size Cooling sized from 95% to 115% (125% limit for heat pumps) or next nominal size (1/2 or 1 ton) 1 Ton of cooling = 12,000 btuh (2.5 Ton Air Conditioner provides 30,000 btuh of cooling) 1 Ton of cooling provides 400 CFM of air flow (2.5 Tons of cooling produces 1,000 CFM of Air Flow)

Equipment Sizing Might is NOT Right when it comes to sizing Oversized systems: Have higher initial costs Reduce efficiency Increase energy costs Compromised occupant comfort Shortens life of equipment

Duct Design ACCA Manual D Provides guidance for proper air distribution Ideal duct systems will be pressure neutral Supply Air CFM = Return Air CFM Ideal duct systems are not exposed to unconditioned space Ideal duct systems supply and return air from the designed locations Ideal duct systems are not leaky Ideally, building cavities are not used as ducts

Symptoms of Leaky Ducts 22

Symptoms of Leaky Ducts There are several key signs of poorly sealed ductwork, including: Higher utility bills Short cycling equipment Unwanted house pressures Leading to uncontrolled infiltration/exfiltration Poor Air Quality As a symptom of uncontrolled infiltration/exfiltration

Reduced Efficiency Air flow at the Indoor Coil Evaporator is designed for a specific air/flow Incorrect air flow does not provide optimal heat transfer Oversized equipment will not properly manage humidity due to short cycling Excessive starting and stopping results in using more power Especially true with ECM motors that will work harder to correct air flow issues from leaky ducts

Short Cycling Equipment Equipment Failure Compressor Compressing Liquid vs. Vapor Additional strain Fans Compressor Condensate Pump

Unwanted House Pressures Leaky Return in Conditioned Basement Worsens already present stack effect Reduces available return air from designed locations (bedrooms) Creates unwanted negative pressure in basement Infiltration of moisture Equipment needs to run more to manage humidity If system is oversized problems are compounded

Poor Air Quality Leaky Ducts and Air Quality Negative pressure in basement draws in humid air Humid air distributed to supply runs Humid air not adequately returned due to leaky ducts

Two Main Reason for Ventilation Fresh air for occupants to breath To dilute air pollutants and excess moisture

Properly Sealed Ducts and Adequate Ventilation Reduces introduction of Natural Pollutants Radon, Gas and oil leaking to the surface, carbon dioxide, ammonia, and methane gas Pollen, mold spores, bacteria, and viruses Helps control Indoor Pollutants Smoke from cooking, dust, bacteria, mites Gases like Carbon monoxide, and VOCs from carpet and furniture Helps control Humidity Reducing latent heat gains Creating a more comfortable and healthy living environment 29

Benefits of tight duct systems 30

Benefits of tight duct systems Primary Benefits: Equipment runs more efficiently and lasts longer Occupants are delivered the right amount of conditioned air to the right places The system is balanced reducing the potential for unwanted positive or negative pressures in building cavities, entire rooms, or other areas of the home Control of unwanted pressures reduces the potential for the infiltration of unwanted contaminants and pollutants

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 2. DUCT QUALITY INSTALLATION All Heating, Cooling, Ventilation, Exhaust, and Pressure Balancing Ducts 2.1 Connections and routing of ductwork completed without kinks or sharp bends. 10 2.2 No excessive coiled or looped flexible ductwork. 11 - Applies to 2.3 Flexible ducts in unconditioned space not installed in cavities smaller than outer duct diameter; in conditioned space not installed in cavities smaller than inner duct diameter 2.4 Flexible ducts supported at intervals as recommended by mfr. but at a distance < 5 ft.

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 2. DUCT QUALITY INSTALLATION - Applies to All Heating, Cooling, Ventilation, Exhaust, and Pressure Balancing Ducts 2.5 Building cavities not used as supply or return ducts unless they meet items 3.2, 3.3, 4.1, and 4.2 of this checklist. 2.6 HVAC ducts, cavities used as ducts, and combustion inlets and outlets may pass perpendicularly through exterior walls but shall not be run within exterior walls unless at least R-6 continuous insulation is provided on exterior side of the cavity, along with an interior and exterior air barrier where required by the Thermal Enclosure System Rater Checklist. HVAC System Quality Installation Rater Checklist

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 2. DUCT QUALITY INSTALLATION 2.7 Quantity & location of supply and return duct terminals match contractor balancing report. 2.8 Bedrooms pressure-balanced using any combination of transfer grills, jump ducts, dedicated return ducts, and/or undercut doors to either: a) provide 1 sq. in. of free area opening per 1 CFM of supply air, as reported on the contractor-provided balancing report; or HVAC System Quality Installation Rater Checklist

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 4. DUCT LEAKAGE 4.1 Total Rater-measured duct leakage < 8 CFM25 per 100 sq. ft. of conditioned floor area 15,16 4.2 Rater -measured duct leakage to outdoors < 4 CFM25 per 100 sq. ft. of conditioned floor area. 15, 16, 17 4.3 Duct boots sealed to floor, wall, or ceiling using caulk, foam, mastic tape, or mastic paste (not required by now recommended, per revision 5)

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 4. DUCT LEAKAGE 4.1 Total Rater-measured duct leakage 8 CFM25 per 100 sq. ft. of conditioned floor area 15,16 4.2 Rater -measured duct leakage to outdoors 4 CFM25 per 100 sq. ft. of conditioned floor area. 15, 16, 17

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 4. DUCT LEAKAGE: (as of 6/10/14) Foot note will be added to Items 4.1.1 and 4.1.2 as follows: For a home with a dedicated return in each bedroom (i.e., not a bedroom pressure-balancing feature leading to a central return), the total Rater-measured duct leakage is permitted to be 1.)The greater of 6 CFM25 per 100 sq. ft. of CFA or 60 CFM25 at rough-in or 2.) The greater of 12 CFM25 per 100 sq. ft. of CFA or 120 CFM25 at final.

Footnote will be added to Items 4.1.1 and 4.1.2 as follows: 4.1.1-2 For a home with a dedicated return in each bedroom (i.e., not a bedroom pressurebalancing feature leading to a central return), the total Rater-measured duct leakage is permitted to be 1.)The greater of 6 CFM25 per 100 sq. ft. of CFA or 60 CFM25 at rough-in or 2.) The greater of 12 CFM25 per 100 sq. ft. of CFA or 120 CFM25 at final. Does not apply unless dedicated returns are in each bedroom. Dedicated high/low returns in each bedroom. HVAC System Quality Installation Rater Checklist

Footnote will be added to Items 4.1.1 and 4.1.2 as follows: 4.1.1-2 For a home with a dedicated return in each bedroom (i.e., not a bedroom pressurebalancing feature leading to a central return), the total Rater-measured duct leakage is permitted to be 1.)The greater of 6 CFM25 per 100 sq. ft. of CFA or 60 CFM25 at rough-in or 2.) The greater of 12 CFM25 per 100 sq. ft. of CFA or 120 CFM25 at final. Jumper ducts. Dedicated high/low returns in each bedroom. HVAC System Quality Installation Rater Checklist

HVAC Distribution Footnotes A Closer Look Footnote 16 extracted Leakage limits shall be assessed on a per-system, rather than per-home, basis. For homes with more than one distribution system, the rater must split out the portion of the homes conditioned floor area (CFA) that each system serves Previously rater would add together the leakage air flow of each system and compare the total amount to the total CFA, this is not allowed in v3

v3 Multi System Leakage Example Home: 2800 sqft, 2 HVAC systems System 1 serves 1200 sqft System 2 serves 1600 sqft. Rater will have to define the splits based on layout and by work with the HVAC contractor What are the allowable leakage levels for v3?

Old Way Total Leakage standard : 8 CFM 25 per 100 ft 2 2800 *.08 = 224 CFM25 allowable System 1 performance tested 54 CFM25 System 2 performance tested 170 CFM25 Total systems leakage = 224 CFM25 It passed! even though system 2 is rather leaky This is not allowed in v3!

Calculating Allowable Duct Leakage v3 To Outside Leakage to outside standard : 4 CFM 25 per 100 ft 2 System 1 serves 1200 ft 2 1200 *.04 = 48 CFM 25 allowable System 2 serves 1600 ft 2 1600*.04 = 64 CFM 25 allowable

Calculating Allowable Duct Leakage v3 Total Leakage Total Leakage standard : 8 CFM 25 per 100 ft 2 System 1 serves 1200 ft 2 1200 *.08 = 96 CFM 25 allowable System 2 serves 1600 ft 2 1600*.08 = 128 CFM 25 allowable

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 4. DUCT LEAKAGE 4.3 Duct boots sealed to floor, wall, or ceiling using caulk, foam, mastic tape, or mastic paste. Optional as of rev. 5 Definitely recommended

Optional as of rev. 5 Definitely recommended

4.3 Duct boots sealed to floor, wall, or ceiling using caulk, foam, mastic tape, or mastic paste. A Boot to floor connection not sealed. Boot to floor connection sealed. HVAC System Quality Installation Rater Checklist

4.3 Duct boots sealed to floor, wall, or ceiling using caulk, foam, mastic tape, or mastic paste. A Boot to drywall connection not sealed. Boot to drywall connection sealed.

ENERGY STAR QUALIFIED HOMES HVAC SYSTEM QUALITY INSTALLATION RATER CHECKLIST SECTION 4. DUCT LEAKAGE: (as of 6/10/14) Footnote will be added to Items 4.1.1 and 4.1.2 as follows: For a home with a dedicated return in each bedroom (i.e., not a bedroom pressure-balancing feature leading to a central return), the total Rater-measured duct leakage is permitted to be 1.)The greater of 6 CFM25 per 100 sq. ft. of CFA or 60 CFM25 at rough-in or 2.) The greater of 12 CFM25 per 100 sq. ft. of CFA or 120 CFM25 at final.

Certification Use the checklist as a sales tool. Third party testing and verification = Confidence Don t forget about the marketing tools available through ES and FirstEnergy Programs 52

ENERGY STAR Sales Tips Become an ENERGY STAR Partner Order ENERGY STAR Marketing Brochures Access My ENERGY STAR Account (MESA) for: Co-Brandable Brochures, Banners and the ENERGY STAR Consumer Video 53

ENERGY STAR Sales Tips 54

ENERGY STAR Sales Tips 55

HVAC ENERGY STAR Credentialing ACCA First Year $275 Application Fee $800 ($600 ACCA members) www.acca.org Advanced Energy Training and Exam Fee: $300 Annual Costs: $600 No additional fees for HVAC job submittals www.advancedenergy.org 57

FirstEnergy New Homes Program Requirements Review Builder incentives $400 per unit + $0.10/kWh in projected savings Eligibility Located in service area of a FirstEnergy Utility Certificate of Occupancy Dates: FirstEnergy Ohio utilities: after March 23, 2011 Met-Ed, Penelec, and Penn Power: after October 28, 2009 West Penn Power: after June 1, 2013 15% more efficient than 2009 IECC (or relevant code when permitted) ENERGY STAR certification 59

FirstEnergy Incentives Review >$1,000 $775 $550 Estimated Incentives These incentive amounts are not guaranteed. Incentives vary by project. 60

Resources International Code Council: http://publicecodes.cyberregs.com ENERGY STAR: http://www.energystar.gov/newhomes DOE Challenge Home: http://www1.eere.energy.gov/buildings/residential/ Passive House: http://www.passivehouse.us Building Science Corporation: http://www.buildingscience.com/ 61

The Next Installment Water Managed Roofs and Walls Thursday, November 13th Noon 1:00 p.m. Registration: https://www2.gotomeeting.com/register/400507394 62