Electric Hand dryer. Installation and operating manual

Similar documents
Hand Dryer Installation & User Manual

^ Blade Hand Dryer Model: GS-2006H SLV

JT-SB116JH-G-NA JT-SB116JH-W-NA

1-3 Komaba-cho, Nakatsugawa City, Gifu Prefecture, Japan

Ultrasonic Aroma Diffuser AD-SD1-CE

IMPORTANT SAFETY INSTRUCTIONS

Manual for Ceiling Patio Heater

Operating Instructions. Model No. EH-NE22/EH-NE11. English 7. (Household) Hair Dryer

DUCTED AIR CONDITIONER. Owner s Manual. KD Series KD24. Kaden Owner s Manual 1

Convection Panel Heater

INSTRUCTION MANUAL HAND HELD STEAM CLEANER JQ688A-1

Dehumidifier. Instruction Manual. Model DH-320/A

Radiant Heater. Instruction Manual QH-200 N13275

DAIKIN ROOM AIR CONDITIONER. Operation Manual

Operating Instructions. Model No. EH-NE34/EH-NE33. English 7. (Household) Hair Dryer

INSTRUCTIONS AND WARRANTY

compact ceramic heater

INSTRUCTIONS FOR CARBON INFRARED HEATER

Pre-Installation Instructions. Installation Instruction. Installation Instructions. kah. wall. Warning. User s Manual and warranty

ULTRA LOW TEMPERATURE FREEZER. User Manual

YOUR SAFETY & INSTRUCTION MANUAL PLEASE READ CAREFULLY HAIR CARE GIFT SET MODEL C85003

GDDEM10 DEHUMIDIFIER

Owner s Manual. Middle Static Pressure Duct Type MEU-18MPH2 MEU-24MPH2 MEU-36MPL2 MEU-48MPL2 MIDDLE STATIC PRESSURE DUCT TYPE AIR CONDITIONER

INSTRUCTIONS AND WARRANTY

KSD-35 DR11 KUE-35 DVN11

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

VL-50S2-E (pull cord Type) VL-50ES2-E (wall switch Type)

Turbo Circulating Fan (DC)

INSTRUCTIONS AND WARRANTY

JUNEAU JUN. 08/51193/0 Issue 0

READ AND SAVE THESE INSTRUCTIONS

15,000 BTU Portable Air Conditioner

Inverter Split-type Room Air Conditioner

Installer manual AG-AA10. Air/air heat pump IHB GB AG-AA10-30 AG-AA10-40/50

40cm Wall Fan With Pull Cord Operation

CA-707. Manual. Read these instructions carefully before you start using the dehumidifier and keep the manual for later usage.

DAIKIN ROOM AIR CONDITIONER. Operation Manual. English. Deutsch. Français. Nederlands. Español. Italiano. Ελληνικά. Portugues. Русский.

Operating Instructions

Curved Metal Panel Heater

Model No: Little Devil II (inc ss)

Always there to help you Register your product and get support at AC4030/00 AC4030/10 Question? Contact Philips User manual

Portable Air-conditioner Use and Care Manual

TAIJI HOTCABI Towel Warmer

Owner s Manual Super-Slim Four-Way Cassette

WINDOW TYPE ROOM AIR CONDITIONER OPERATION AND INSTALLATION MANUAL

infrared paraffin / kerosene / diesel heater

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

INSTRUCTION MANUAL EPH-121 CONTENTS

THERMO POT MODEL: ETP-G5083(CG) Owner s Manual. For The Warranty Terms & Conditions, Please Refer To Warranty Certificate.

PROLUX AIR PURIFIER / HUMIDIFIER MODEL: PL-2 Operation Instruction

OPERATING INSTRUCTIONS

User Manual. 3.5L Deep Fryer Stainless Steel Model Number: MDF35S READ AND SAVE THESE INSTRUCTIONS

9 LITRE DESICCANT DEHUMIDIFIER INSTRUCTION MANUAL

ELECTRIC HEATER WITH CARBON FIBER HEATING ELEMENTS

Use & Care Manual Electric Portrait with remote control DBL-2000-DD5

30-pint Dehumidifier User Guide

Dehumidifier. User Manual

User Guide. For THE SWIMSUIT DRYER. Swimsuit Dryer manual Final 120v 60Hz. Copyright 2017 Page of 20

USER S MANUAL. Bottom-Load Water Cooler MODEL NO. CLBL420

Portable Air-conditioner

OWNER S MANUAL KPD-105 DTN11 KPD-140 DVN11 KPD-140 DTN11 KPD-160 DTN11 KPD-52 DVR11

Induction Fryer. Instruction manual. Model Modèle Modell Modello Modelo Malli: CP793

NORTH STORM. 4-in-1 AIR CONDITIONER USER MANUAL TABLE OF CONTENTS

Removing shipping locks

Hair dryer INSTURCTION MANUAL. Model No.: RCY-82

INSTALLATION AND USER S MANUAL COOKER HOOD RS-600/A-S

PRESSURE WASHER MODEL NO: JETSTAR 1750 OPERATION & MAINTENANCE INSTRUCTIONS. WARNING Read the instructions before using the machine PART NO:

THROUGH-WALL AIR-TO-AIR HEAT PUMP AND AIR CONDITIONER. Instruction Manual. Model AMB-12H

MeacoDry ABC Range Dehumidifiers

PKWK43. Electric Thermo Pot

AMBION FLAME. INSTALLATION AND USER INSTRUCTIONS

OPERATING INSTRUCTIONS

Portable Air Conditioner. Instruction Manual

Operating instructions

High-Pressure Washer BY02-VBP-WTR BY02-VBP-WTH. CAUTION : Do not use this device before reading the instructions.

Radiance Infrared Outdoor Heater 2000W Installation Manual

Contents. Warning: Installation... 2 Warning: Operation...2 Warning: Disposal...3

METAL CERAMIC FAN HEATER

Operating Instructions. Accessory Units Melitta Cafina XT Series. Melitta Professional Coffee Solutions

Operating Instructions

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

MULTI - CYCLONIC VACUUM CLEANER VCC 7070

Adjustable Standing Patio Heater 2000w

R410A SPLIT SERIES FIXED SPEED

TWLRZ-238 REFRIGERATOR

40cm Pedestal Fan with Remote Control

HAIR DRYER TRAVEL Move HD 2509

Installer manual AG-WL10

INSTRUCTION MANUAL FOR ELECTRIC RADIANT INFRARED HEATERS

Compact Cyclonic Bagless Upright Vacuum Cleaner

HEA-900 EDENPURE INDOOR/OUTDOOR ALL SEASON INFRARED HEATER

BLOW DRY & GO HAIR KIT

Coway Air Purifier AP-1008DH

85 Series USER MANUAL

IMPORTANT- RETAIN FOR FUTURE REFERENCE CALL:

WARNING: Warns of health hazards and identifies possible risks of injury. CAUTION: Indicates possible dangers to the machine or other objects.

PolySprint. Operation Manual PSM-NIT-13004E. Follow this manual when using Nitta PolySprint Heat Press.

1500W Black Glass Portable Electric Panel Heater KAHTP20BLKA

Meaco 10L small home dehumidifier Instructional Manual

SAFETY AND OPERATING MANUAL. Original instructions 2000W WALLPAPER STRIPPER

Transcription:

Electric Hand dryer Installation and operating manual

Do not attempt to install the unit yourself unless you are a trained service technician. Otherwise, this may affect safety and proper functioning of the unit. Read this manual thoroughly and carefully before using the unit to ensure safety and proper function. Keep this manual for later reference Contents, Features, Specifications Warning Parts, Dimensions explained Usage Routine cleaning Troubleshooting, Electrical schematic Before installing the hand dryer Installation Test run Packing list Contents Features Hygienic contact-free hand drying solution High speed hand drying ensures low energy consumption Efficient design, easy to use Anti-damage timer for safe use Does not require use of towels or tissues; is waste-free Made of anti-bacterial and environmentally friendly material Automatic heater for comfortable warm hand drying in winter Equipped with a filter for automatic sterilization (HEPA filter) Anti-damage timer & cool hand drying regime in summer An anti-damage timer enables this machine to automatically stop working after 25 seconds. When this happens and if you wish to continue using the machine, take your hands out and insert them again into the dryer; the unit will start working automatically. No add. windpipe Sensors Designed in accordance with human engineering Sensors Airflow Air inlet Isolated hygienic air supply equipped with water dripping prevention mechanism No spatter Easy to use Specification Rated voltage AC 220-240V~ 50/60 Hz Motor Brushless DC motor Power without heater 650-800W Protection class IPX4 Power with heater 1650-2050W Dimensions 300x212x700mm Wind velocity 95m/s Net weight 11KGS

WARNING Improper use increases risk of personal injury! Prohibited Do not use in the bathtub or shower room Do not allow the unit to get wet. Do not open the front panel, otherwise this may result in an electric shock Children must not hang on the unit to avoid the risk of falling Do not use in a wet environment, for example near the bathroom where the unit may get wet and places with forming condensation, otherwise this may result in an electric shock and unit malfunction To avoid the risk of an electric shock, keep the unit dry at all times Do not modify and disassemble the unit unnecessarily. Otherwise this may cause a fire, an electric shock, or personal injury Rated power is required If power tolerance is over ±10% there will be breakdown. Using incorrect power supply can cause fire, an electric shock and machine malfunction Use dedicated sockets only. Sharing a socket with other appliances may cause overheating and start a fire Prohibit disassembling Comply with instructions Power must be cut off during maintenance to prevent the risk of an electric shock and air filter must be installed. Do not turn on the unit for 10 seconds after plugging it in If the unit doesn't work or exhibits abnormalities, cut off power to prevent accidents, close leakage circuit breaker and ask supplier to check and repair, or it may lead to a fire because of electricity leakage and short circuit The unit must be supplied with a reliable growing wire to avoid the risk of an electric shock in case of a failure or a leak Ground Attention when installing the unit: do not install while the unit is plugged in Installation must be performed by a professional construction worker. Incorrect installation can cause an electric shock and a fire accident WARNING The unit is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the unit by a person responsible for their safety. If the cord is damaged, it must be replaced by the manufacturer, its service agent or similarly a qualified person in order to avoid a hazard. For additional protection, the installation of a residual current device (RCD) having a rated residual operating current not exceeding 30mA is advisable in the electrical circuit supplying the bathroom, ask your installer for advice. Environmental hazard Electrical waste should not be disposed of together with household waste. Recycle where facilities exist, check with your local authority or retailer for recycling advice.

Parts and dimensions specifications Drying time and fault display Power supply ON H Heating button Speed button Power switch Power indicator Filter sterilization indicator Self-check indicator Sensor ON OFF L POWER OFF Hand drying area Unit Lock Drain hose Switch door plate Bottom Pick outlet Air inlet panel Plug holes for attachment Full level indicator Lock Air inlet Air filter Hook Terminal box

Usage How to use Stretch both hands out and insert all the way in. The unit will start automatically. Withdraw hands slowly, letting the air blow residual. Pull hands out entirely. When using the unit Turn on the power switch, when the power indicator lights up the lamp lights up the lid of power supply is closed Usage label How to use the hand dryer try air. Dry your handy in up to 10 seconds. Place the usage label on a visible spot (on the front of the unit or on the wall next to the unit). Stretch both hands out and insert all the way in Withdraw hands slowly... Let air circulate and blow off residual water.

Routine cleaning Cleaning the unit Before the unit gets obviously dirty If the unit is very dirty, clean with a soft cloth dampened with neutral agents, then clean with a dry soft cloth. Remove dirt from the sensor (to prevent malfunction). Note! Only use neutral cleaning agents. Do not use thinners, acidic or alkaline toilet cleaners, or a nylon brush, (otherwise they may damage the smoothness of surface) Use only alcohol to clean hand drying area (do not use alcohol anywhere else on the unit). Alkohol = alcohol used for disinfection ( with concentration below 83%. ) Application of disinfectants will damage your unit. Draining and cleaning the drain tank Clean the tank before it fills up ( at least once a week) The water blown off the hands in called drain water. Empty the drain water at any moment to prevent accumulated water from exceeding the maximum allowed capacity. The tank will start emitting unpleasant odors if the accumulated water remains in the tank for too long. WARNING Before cleaning the unit, turn off the power switch. Do not splatter water on the unit. CAUTION Wear gloves when cleaning the unit. The unit's antibacterial coating is effective when the bacteria are exposed to the coated surfaces. The antibacterial coating loses its properties when surfaces get very dirty. Cleaning the air filter Around once a week Remove the air filter Open the air inlet panel and pull out the air filter by the handle Pull the drain tank out horizontally so as not to spill the drain water. Maximum level 1. Open the lid and empty the water. Pull the lid up with your fingers on both sides, remove the cover. 2. Wash out the interior of the drain tank. 3. Put the lid back on and reattach the tank to the unit. Lid 1. Cleaning the air filter Remove the dust using a vacuum cleaner, a hairbrush or emptying it on the surface 2. Reattach to the unit I nsert the filter all the way in. If the filter is installed incorrectly or is absent, dirt or dust will penetrate the unit and shorten its service life. Lid Note! Do not wash air filter with water or any other linquid! Run 200cc ( around 1 cup) of water through the drain hole to prevent it from getting clogged. Use the unit after making sure the water tank is reattached correctly. Drain hole

Problem No air blows even if hands are inserted. The unit continues working when hands withdrawn, then shows E2 status. No hot wind. Airflow is too low. Trouble shooting, Electrical schematic If the following situation occurs, follow the guidelines to resolve the problem. Check Are indicators correctly displayed? Is the power on? Are you inserting your hands all the way in? Any dirt or foreign object on the sensor? Is the heater switched on? Any dirt on the sensor? Is the fuse inside the terminal box blown? Is the speed button set on low? Action Turn the ground-fault circuit breaker on. Turn the power switch on. Insert hands all the way in. Turn the unit off by switching off the power button, remove dirt or foreign objects on the sensor after the power light has gone out. When finished, switch on the unit by turning on the power button. Is the ambient temperature higher than 20 C? Turn the unit off, remove the front lid, and locate a terminal box inside. Take down the lid of the terminal box. Inspect the fuse inside the box. Adjust airflow speed by setting the speed button higher. If the above actions do not work, turn off the unit and the ground-fault circuit breaker, and call your dealer to inspect and repair the unit if necessary (costs are as per agreement with the dealer). Electrical schematics Fuse Control PCB Motor Power switch Thermal protection switch Temperature probe Thermal circuit breakers Heating Wiring terminal blocks Fuse Compensation probe Temperature probe Display PCB Sensor receiving PCB Sensor Start PCB Power Indicator light State Indicator light Timing digital tube Power Status Introductions Status Introductions Solution Light Power input normal Extinguish No power supply Master fuse blew out Extinguish Don't work Motor fault, it cannot Flashing start normally Always light Working light Trick or working time longer than 25s Digital Countdown work Jump display Drying circle completion changes indicator The unit won't start normally. Motor failure. The voltage exceeds 15% Machine temperatures higher than 80 C Trick or working time longer than 25 seconds. The voltage lower than 15% Master boardtemperatures higher than 80 C. Fan failure. Check external power source. Turn off power. Inspect connecting wires and motor for presence of debris. Clear workspace from all foreign material, restart the unit. Clear workspace from all foreign material, restart the unit. Check the power supply circuit. Clear the air inlet and air outlet from debris. Check whether the fan sensor wire is loosened.

ON ON H OFF L POWER OFF Before installing the hand dryer Do not install the unit in the following types of environment, otherwise this may cause malfunction: Locations where temperatures can exceed -10 C or 40 C Locations where the unit may come into direct contact with water Locations where the unit is under direct or strong sunlight Locations with high humidity levels Locations where corrosive, neutral, or reductive gases are present in the air Locations higher than 2,000m above the sea level Installation location Install the hand dryer in a location where it will be easy to use, and ensure that there is adequate space around the dryer for cleaning and maintenance. If the unit is installed too low, water may splash onto the dryer when the floor is being cleaned. (The bottom of the hand dryer must be mounted at least 150mm above the floor). Avoid installing the hand dryer in locations where people or doors might bump into the dryer. Choose a completely flat surface on the wall to install the dryer. Network connectivity It is recommended to connect the unit sideways next to the socket on the wall. The socket should not appear under the unit so as to guarantee easy access to the unit's filter. Direct connection to a flush device box. Screws Installation panel Installed terminal box Unit Safety screws Recommended Installation heights (from the floor level to the upper side of the unit) 1000mm for man 950mm for woman 860mm for children/disabled Distance between the terminal box without cover and the ground Power switch Stromversorgung Installation panel Air filter Terminal box

250mm Installation procedure Pay attention to the correct power supply ( single-phase). Deviations can lead to failure. Use only suitable cable from the specialized trade for the electrical installation. ( If you have no experience in the field, so please contact a qualified installer) Wire the unit Power cords Connect the power cord to the cables from the flush-mounted box. In order to ensure a flush and secure wall mounting, neither socket cover neither socket cover nor other obstacles may impede proper assembly Fix the mounting plate on the wall with the provided screws Installation plate Use appropriate dowels according to the nature of the substrate (concrete, masonry, etc.) Screws Make sure that the wall is stable enough for the assembly. Drilling template Flush-mounted box 5 645 Attach the drilling template to the wall and drill the holes. Holes for safety screws 130 Place dowels into the holes and firmly fasten the mounting plate with screws. 1. Prepare the electrical installation If the unit is plugged in, follow steps 6 and 7. If the unit is connected to electricity with the wire, first pull out the electric cover and power cords Air filter Remove the drain tank and the air filter 2. Removal of electric cover and power cords (1) Unscrew the 2 screws on the electric cover, open the cover. (2) Unscrew the 2 screws on the power cord clamp, loosen the 3 screws on the terminal box, then pull out the power wire. Terminal box Power cord clamp Cover Power cord Connecting separate power cables into the unit The device is already provided with a 1.5 m long power cable. If you want to use a different cable, follow the procedure as described below: Lift the unit up to a comfortable working height (250-300mm) and connect the unit as follows: Power cord Power cord clamp (1) Remove the insulation of the power cable (2) Connect the power cable to the terminal block of the device (3) Tighten the screws in the terminal block and make sure that the cable is firmly seated. Terminal box Ground 40 10 (4) Secure the power cord with the power cord clamp! Underlay ( by the customer) WARNING: Risk of electric shock

Installation Procedure Install the terminal block cover (1) Put the terminal block cover on the terminal block and fix it with installation screws. (2) Make sure that the power cable has enough room and the lid is mounted flat. Terminal box Power cord clamp Power cord Cover Fix the unit (1) Tidy the power lines and press excess cords into the terminal block on the wall (2) Place the hook on the back of the unit into the hanging trough of the installation panel, make sure the unit is stable, and close to the wall (3) Tighten the securing screws! Installation plate Unit Safety screws Hook Note: The safety screws provide additional protection against unwanted disassembly! 1. Insert the air filter Push the air filter up into the unit towards the end, then close the air inlet door and lock it. Unit 2. Insert the drain tank Push the drain tank into the unit as shown in the diagram. Air filter Test run Required steps Check Result Check the voltage of power supply Please use the rated voltage. Turn the ground-fault circuit breaker on Turn the power switch on Dry hands Does the power indicator light up? Is the air blowing? Check the unit Do not turn the power switch on with your hands inside the unit! Is the unit installed firmly? Any vibration or strange noise?

Packing list Unit Installation plate Installation dowels 10 Installation srews 10 Users manual Application use Drilling templates

Pallischgasse 27 AT-2486 Pottendorf E-Mail: mail@andarsen.com http://www.andarsen.com This product conforms to all EU directives. 2014 Andarsen GmbH. This document may not, in whole or in part, reproduced, distributed, modified or used in any other way without prior written permission. All trademarks referenced herein are the property of Andarsen GmbH.