NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80

Similar documents
HAP e-help. Modeling Induction Beams in HAP v4.8 QB TIP 001

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Summary Comparison of Simulation Program Features

State of the art building simulation software... Frenger Radiant chilled beam performance at 1 Shelly St - Sydney

CARRIER edesign SUITE NEWS. Modeling 100% OA Constant Volume Air Systems. Volume 6, Issue 1. Page 1 Modeling 100% OA Constant Volume Air Systems

Retrocommissioning Findings Summary: Building X #1 Priority: Major Comfort/Control Problems

HVAC 101. H V A C S y s t e m s

CARRIER edesign SUITE NEWS. Interpreting High (Low) Peak Design Airflow Sizing Results for HVAC. Equipment Selection.

INTRODUCTION HVAC BASICS AND HVAC SYSTEM EFFICIENCY IMPROVEMENT SECTION O 4/19/2012

Chilled beams. TRACE 700 incorporates two chilled beam strategies: passive and active.

TRACE 700. Slide 1. Hello, my name is Nick Cavitt and I m a marketing engineer in the C.D.S. group at TRANE.

CONTROLLED CHILLED BEAM PUMP MODULE

Mechanical System Redesign. Dedicated Outdoor Air System. Design Criteria

The Creative and Performing Arts High School (CAPA) Pittsburgh, PA 11/11/2002 Andrew Tech Mechanical Option Prof. S. A. Mumma

APPLICATION GUIDE BEAMS

V4 15JUNE2016 (COPYRIGHT: DEPARTMENT OF INDUSTRY)

INTRODUCTION TO: ASHRAE STANDARD 90.1, HVAC System Requirements for Reducing Energy Consumption in Commercial Buildings

SEQUENCE OF OPERATION GUIDELINE. AIR TERMINAL UNITS SINGLE DUCT VARIABLE AIR VOLUME with HOT WATER REHEAT or ELECTRIC HEAT

CONTROLLED CHILLED BEAM PUMP MODULE

Dehumidifying with Dedicated Outdoor Air

Improving Performance with a Building Tune-Up. Janice Peterson, P.E. LEED AP Market Manager, Building Operations BetterBricks

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

COMcheck Software Version Review Mechanical Compliance Certificate

ApacheHVAC in VE 2012

Product Data. Features/Benefits. 36CBAC,AE,AF,AH,AQ,AN, PB,PD,PS Series Active and Passive Chilled Beams. 11 to 190 cfm

A. Base Bid: 1. Heating Contractor provide: a. Control sequences for HVAC systems, subsystems, and equipment.

Direct and indirect evaporative cooling

Job Name Control Systems Description Date

AIR-CONDITIONING SYSTEMS AND APPLICATIONS. Abdullah Nuhait Ph D. King Saud University

ENGINEERING BULLETIN. Overview of Chilled Beam Technology. Purpose. Summary. Theory

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

HVAC Controls Upgrades: Requirement Details ( )

HVAC Controls Upgrades: Requirement Details ( )

ENERGY EFFICIENCY WITH SUPERIOR INDOOR AIR QUALITY

7. MECHANICAL SYSTEM DESIGN

NOVEMBER 2012 THE EUROPEAN EXPERIENCE

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) 2016 Q1

terminal units only provide sensible cooling, a separate dehumidification system is usually needed.

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

The new ASHRAE-REHVA Active and Passive Beam Application Design Guide

1 - This title will copy onto other forms Date

MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION CONDITIONS FACILITIES MASTER PLAN MAY

2009 IECC Commercial Mechanical Requirements

AC SYSTEM CONFIGURATION- CENTRAL CHILLER PLANT

1. Packaged Variable Air Volume (VAV) Rooftop Units (RTU) with Hot Water Reheat. 2. Geothermal Heat Pump VAV Rooftop Units with Hot Water Reheat

Single Zone System. One duct system Used mostly in small buildings Forced air system All spaces controlled by a single thermostat Single air return

RSES Technical Institute Training Manual 3 72 hours, 72 NATE CEHs, 7.2 CEUs

COMMERCIAL HVAC PACKAGED EQUIPMENT. Split Systems

High-Performance VAV Systems

HVAC Mandatory Provisions Part II, Page 1

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

New Features. IES Virtual Environment 6.4

EADQUARTERS. Technical Report One. Stephanie Kunkel Mechanical Option

Technical Assignment 3. Mechanical Systems Existing Conditions Evaluation

HONORABLE MENTION: COMMERCIAL BUILDINGS, EXISTING

b.) Technical Information:

Design Standard. Thermal Systems (Chilled Water and Hot Water Systems) Detailed specifications follow. CHW AND HHW SUPPLY TEMPERATURE RESET

Description of All Alternatives Considered-

CHAPTER 4. HVAC DELIVERY SYSTEMS

HVAC DISTRIBUTION and DELIVERY SYSTEMS

SPLIT SYSTEMS SELECTION & OPTIMIZATION GUIDE

Topic 2. ME 414/514 HVAC Systems Overview Topic 2. Equipment. Outline

MAXIMIZING HYDRONIC SYSTEM DESIGN PART III

Appendix 13. Categories of Cooling and Heating systems

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

DX-9100 Applications from Engineering Services

2. CURRICULUM. Sl. No.

COMMERCIAL HVAC EQUIPMENT Coils: Direct Expansion, Chilled Water, and Heating

COMMERCIAL HVAC EQUIPMENT Indoor Self-Contained Units

Technical Report #3 Mechanical Systems Existing Conditions Evaluation

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

4-Pipe VAV vs. Active Chilled Beams for Labs

MicroTech Rooftop/RMC

DISTRIBUTION SYSTEMS. Water Piping and Pumps

Submitted to. Texas A&M University at Galveston The Texas A&M University System. Submitted by. Yeqiao Zhu Dan Turner David Claridge

Ball State Architecture ENVIRONMENTAL SYSTEMS 2 Grondzik 1. Contextual Reminder

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Benefits Offered by Passive Dehumidification Wheel Speed Control

Mechanical Redesign, Proposal Elizabeth C. Krauss Mechanical Option September 18, 2013

Strategies for Building Energy Efficiency

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Modeling projects that require very tight space temperature control

Continuous Commissioning: A Valuable Partner to Retrofit Projects

Case Study: Furman University Charles H. Townes Center for Science. Michael K. Mantai, PE, CCP President System WorCx

Your Home. Jacco & Assoc.

Feature Summary. I. System

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

Inspection Phase Three. Mechanical, Electrical & Plumbing Section 503

Mechanical Technical Report 3. Mechanical Systems Existing Conditions Evaluation

SECTION SEQUENCE OF OPERATIONS FOR BUILDING CONTROLS

SECTION REFRIGERATION. 1. Reciprocating Compressors (Hermetic). 2. Reciprocating Compressors (Open Drive). 3. Water Cooled Condensing Units.

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Mechanical Systems Design

Do All DOAS Configurations Provide the Same Benefits?

Contact Information. Steven Potratz, P.E. WSU Facilities Services, Engineering Services Manager Phone

Verasys System Operation Overview Technical Bulletin

SPACE CONDITIONING IN COMMERCIAL BUILDINGS Overview

ASHRAE Illinois Chapter 2015 Excellence in Engineering Awards

Transcription:

NEW FEATURES IN THE CARRIER HOURLY ANALYSIS PROGRAM v4.80 Carrier Software Systems Carrier Corporation Syracuse, New York rev October 10, 2013 Copyright 2013 Carrier Corporation, All Rights Reserved Page 1 of 6

Table of Contents 1. Summary List of Enhancements in v4.80... 2 2. New Air System Features... 3 3. New Plant Features... 4 4. New Equipment Wizard Features... 4 5. Other Features... 4 6. Bug Fixes... 5 1. Summary List of Enhancements in v4.80 This document describes enhancements in the Carrier Hourly Analysis Program (HAP) v4.80, released in October, 2013. It is intended for new users and those upgrading from HAP v4.70. A summary list of enhancements is provided below. Sections 2 through 6 describe the changes in greater detail. 1. Air Systems Added two new air system types: Induction Beams (IB) and Active Chilled Beams (ACB). This includes default settings and values for all inputs. Added design calculations for IB and ACB systems, as well as associated reports. Added energy simulation calculations for IB and ACB systems. Added export of Induction Beam sizing data to Carrier Electronic Catalog for equipment selection. See section 2 for further details 2. Plants Added ability to model waterside economizer with air-cooled chiller plants. See section 3 for further details 3. Equipment Wizard Added two new air system types: Induction Beams (IB) and Active Chilled Beams (ACB). This includes default settings and values for all inputs, and intelligent defaulting when transitioning from the Wizard screens to the full HAP project. Also added new graphics for IB and ACB terminals in the air system diagram. See section 4 for further details 4. Other Features Updated Help Menu items to improve connectivity with Carrier help desk. Improved compatibility with computer configurations using dual monitors. Improved compatibility with computers having touch-screen capabilities. See section 5 for further details 5. Bug Fixes Corrected problems reported in HAP v4.70 See section 6 for further details Page 2 of 6

2. New Air System Features 1. Induction Beam Air Systems A new type of air system has been added for modeling induction beams (IB). Induction beam systems consist of a central ventilation unit (DOAS) and one or more induction beam terminals. The terminals provide hydronic cooling for sensible and latent loads, and optional hydronic heating. A number of features were added to control ventilation system behavior in unoccupied periods: ventilation air damper position, reset of DOAS supply temperature setpoints, reduction in ventilation fan airflow, and control options for the ventilation fan. These features allow system designers to tune the overall performance and energy usage. The induction beam terminal units can be individually configured. Performance is specified by setting the values of airflow ratio and coil bypass factor. 2. Active Chilled Beam Air Systems A new type of air system has been added for modeling active chilled beams (ACB). These systems consist of a central ventilation unit (DOAS) and one or more active chilled beam terminals. The terminals provide hydronic cooling for sensible loads only, and optional hydronic heating. Active chilled beams share some of the capabilities of induction beams, although because they cannot handle latent cooling loads at the air terminal (due to condensation on coil surfaces), the available options are fewer. Dehumidification settings are also of primary importance. Features available to ACB systems include unoccupied ventilation air damper position and reset of DOAS supply temperature in unoccupied periods. Individual ACB terminals are configured similar to induction beam terminals. 3. Design and Energy Simulation Calculations and Reports The new induction beam and active chilled beam air systems have been integrated into HAP's design sizing and energy simulation calculations, as well as the suite of reports available to display the results of the calculations. While most of this integration is invisible to the user, some modifications have been made to adjust the reports for these system types. For design calculations, system design reports have been customized for Induction Beam and Active Chilled Beam applications. For energy simulations, annual, monthly, and hourly results were integrated into existing reports and reporting categories. 4. Export to Carrier Electronic Catalog Equipment sizing results can be exported to Carrier Electronic Catalog (E-CAT) for use in selection of induction beam terminal equipment. This is done using the "Publish Equipment Sizing Requirements" button on the toolbar or the corresponding option on the Project Menu. This "Publish" feature also allows sizing requires for many other types of equipment to be exported to E-CAT. Page 3 of 6

3. New Plant Features 1. Waterside Economizer for Air-Cooled Chiller Plants Added the ability to model water-side economizer free cooling in chiller plants using air-cooled chillers. In such a plant a cooling tower or dry cooler turns on and operates when it can deliver cold enough water to provide 100% free cooling (non-integrated waterside economizer) or when it can deliver cold enough water to precool return water and provide partial or 100% free cooling (integrated waterside economizer). Previously this feature was limited to chiller plants containing water-cooled chillers. To use this feature: a. Create a chiller plant. b. On the Configuration tab check the box for free cooling and specify the type of free cooling. c. Also on the Configuration tab, specify that "one tower is shared by all water-cooled chillers". In a plant containing only air-cooled chillers, this will mean one tower or dry cooler is shared among the air-cooled chillers for purposes of free cooling. d. On the Schedule of Equipment tab select the cooling tower, dry cooler or geo/well source that will serve as the heat rejection system providing the free cooling. During the plant simulation, the software will evaluate hour by hour conditions. When conditions are favorable for free cooling the heat rejection system will turn on to provide partial or 100% free cooling, depending on the type of free cooling specified and the current conditions. 2. Distribution Loop Delta-T The maximum delta-t which can be specified for a distribution loop for hot water applications has been increased to 100 F (55.5 K). This exceeds the 50 F minimum requirement needed to comply with LEED 2009. This is also consistent with hot water boilers, which already allowed a maximum delta T of 100 F when specifying their flow rate in relative terms. 4. New Equipment Wizard Features 1. Induction Beam and Active Chilled Beam Air Systems Added features for modeling Induction Beams (IB) and Active Chilled Beams (ACB) in the Equipment Wizard. When one of these system types is selected, the wizard screens will display only the set of inputs which are relevant. To depict the configuration of these new system types, new graphics for IB and ACB terminals have been created for the air system diagram. These simple diagrams depict the basic functionality of the terminal units, including the induced airflow and zone recirculation as well as chilled and hot water coils. They are visually distinct from other terminal unit types in order to reinforce these concepts and ensure clarity. Page 4 of 6

5. Other New Features 1. Help Menu Options From the Help menu, the Contact Customer Support window now contains a clickable email address which will automatically launch the user s email program and pre-populate an email with the e-mail address for Carrier Software Systems as well as basic details of the version of HAP being used.. This information assists customer support personnel in diagnosing certain types of software issues. Using this functionality to initiate contact with Carrier is recommended. From the Help menu, the About window now will display basic software and system information. This will facilitate support when calling the Carrier help desk. 2. Compatibility with Dual Monitor Computer Configurations In certain situations the left-hand tree panel in HAP's main window became unresponsive. The program did not respond to clicking items in the left-hand panel. This error only occurred on computers using two monitors in which specific configuration settings were used, and HAP was running on the secondary monitor rather than the primary monitor. HAP has been upgraded so it should now run on all dual-monitor configurations. This issue was present in both v4.70 and earlier versions. 3. Compatibility with Touch Screen Computers When starting the program on a computer having touch screen capabilities the program would halt and display Windows operating system message "Hourly Analysis Program has encountered a problem and needs to close". HAP has been upgraded so it is now compatible with desktop, laptop and tablet computers having touch screen capabilities, as long as that computer is running a Windows operating system. 6. Bug Fixes This section describes problems identified in HAP v4.70 which were corrected in HAP v4.80. 1. Plant Design Calculations I In certain situations, when running plant design calculations for a Service Hot Water (SHW) plant or a Hot Water Plant or Steam Plant which served both space and SHW loads, the calculation halted and displayed an error message "Error 6 Overflow for SHW Plant Design Calculations". This problem only occurred if the SHW maximum consumption rate was defined in terms of gal/person/day (L/s/person/day) and the occupant population was larger than 1450. 2. Plant Design Calculations II When plant design calculations were run for one of the "Generic" plant types, any required air system design calculations were not automatically run first. This resulted in plant peak load being incorrect. Note that if design calculations for the air systems served by the plant had previously been run after the latest changes to the system, no error occurred. The error only occurred if air system design calculations had not previously been run at all, or if changes to the air systems had made since the design calculations were last run.. 3. Plant Design Calculations III In certain situations, when running plant design calculations for a Service Hot Water (SHW) plant or a Hot Water Plant or Steam Plant which served both space and SHW loads, the calculation would halt and display an error message "Unable to load schedule data." This problem only occurred if air systems served by the plant have one or more spaces containing zero occupants. 4. Editing Plants I In certain situations, when opening the Plant Properties window to edit data, the program halted and displayed the following error "Error 91 Object Variable or With Block Variable Not Set". This problem only occurred if one of the air systems linked to the plant had been changed to use a different source of cooling or heating. For example, this could involve a system originally Page 5 of 6

defined as a chilled water AHU which was linked to a cooling plant, and then later the system was changed into a packaged rooftop and therefore no longer contains chilled water coils. 5. Editing Plants II - For an unusual sequence of steps, the shared ground source for a hot water plant using water-to-water heat pumps was not displayed on the plant properties window or the plant input report. The required sequence involved starting with a project created in HAP v4.6 or a prior version that contained a hot water boiler plant, converting the data to HAP v4.7 format, editing the boiler plant and changing it to use water-to-water heat pumps and a shared geo source. This data is correctly saved and used in calculations. But if you later edit the plant or generate the plant input report, the shared geo source will not be displayed. 6. Editing Plants III - When running HAP with energy analysis features turned off and hidden, the program did not offer options in the plant inputs for choosing plant types "Generic SHW Plant" and "Generic Changeover Plant". 7. Editing Plants IV - When running in SI Metric units and defining a hot water plant or chilled water plant with a primary/secondary distribution system, the secondary pump design flow rate is incorrectly displayed on the Distribution tab. This value is automatically calculated from the equipment specified on the Schedule of Equipment tab. The calculated value is correct and will be correctly used in calculations. The error is only in the screen display of the data. If you generate a plant input report you will see the flow correctly displayed there. 8. Editing Plants V - When running in SI Metric units and defining a remote chilled water or remote hot water plant the secondary pump flow rate defined on the Distribution tab is incorrectly saved. This will cause simulated pump input energy to be incorrect. 9. Air Systems When a cooling-only air system was defined with dehumidification control and the dehumidification reheat source was defined as hot water or steam, HAP failed to properly record the reheat source. This prevented linking the air system to a hot water plant or steam plant. As a result, energy costs for dehumidification reheat could not be calculated in this case. This error was present in both v4.70 and earlier versions. 10. Editing Air Systems I Under certain conditions, when adding spaces to zones in an air system, some of the items in the "selected spaces" box were shown as blank lines. This was a display issue only. The selected spaces were properly saved and used in calculations. 11. Editing Air Systems II - For Rooftop, Vertical Packaged Unit and Split DX AHU VAV systems, if one of the temperature reset options was chosen for cooling capacity control, the next time the system was edited, the program changed capacity control to "cycled or staged capacity, fan on". The original reset control was saved and used in calculations. The problem only occurred if the system was later edited. 12. Program Startup - When starting the program for the first time, the program would halt and display an error message "Run time error 372. Failed to load control 'RichTextBox' from 'RICHTX32.OCX". This error only occurred on certain configurations of Windows 7 and Windows 8 computers. This error was present in both v4.70 and earlier versions. Page 6 of 6