HVAC HEATING PRODUCTS

Similar documents
HVAC HEATING PRODUCTS

Gas-Fired Heating Equipment

HVAC HEATING PRODUCTS Application Manual

GQVC-12 HVAC EQUIPMENT. GAS-FIRED INDOOR HEATING EQUIPMENT A complete line of effi cient heating solutions for large, open spaces.

SUH-8 UNIT HEATERS. High Efficiency Heating Equipment

BTUC-4 TUBULAR GAS-FIRED UNIT HEATERS

HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-22

Product Catalog Gas Heating Products: Indoor and Outdoor Units

FEATURES AND BENEFITS

Gas-Fired Indoor and Outdoor Duct Furnaces

HVAC EQUIPMENT for Residential, Industrial & Commercial Applications GACP-20

SUBMITTAL SCHEDULE & DATA

bring value to your space

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

GAS-FIRED POWER VENTED UNIT HEATERS PROPELLER & BLOWER MODELS

Refer to the Page 23 (inside back cover) for Model Nomenclature. Table of Contents

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

Installation, Operation and Maintenance

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

Gas-Fired Indoor and Outdoor Duct Furnaces

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

HIGH EFFICIENCY GAS-FIRED, UNIT HEATER LIST PRICES

GAS-FIRED UNIT HEATERS RESIDENTIAL, COMMERCIAL & INDUSTRIAL

Upflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

Indirect Gas-Fired Make-Up Air

Submittal. Date: January 8, Customer P.O. Number: Customer Project Number: CARROLLTON, TX 75006

KIC Air Curtains. Technical Guide

Gas-Fired Unit Heaters Commercial & Industrial

Downflow/Horizontal Right Induced Draft Gas Furnace

Product Data. 58EFA Horizontal Gas Furnace. 50, ,000 Btuh Input

COMPACT UNIT HEATERS Low Profile - Horizontal - 60 HZ. Steady-State Efficiency - up to 81% Input - 30,000 to 75,000 Btuh

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

ADF/ADFH 300 and 500

GARAGE / WORKSHOP INFRARED HEATERS

8+* Bulletin No November 1997

Upflow/Horizontal Condensing, Gas-Fired Furnace

TECHNICAL SPECIFICATIONS

AUGUST, High-Efficiency Condensing Gas-Fired Separated Combustion Unit Heaters

M3RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U3-SUB-1-EN. February 2016 S9V2B080U3PSAA TAG:

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

AHC-2. OUTDOOR AIR HANDLERS Application Manual

INSTALLATION INSTRUCTIONS AND PARTS LIST TUBULAR GAS FIRED PROPELLER UNIT HEATERS

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 80,000 BTUH S9V2B080U4-SUB-1-EN. February 2016 S9V2B080U4PSAA TAG:

Submittal. Upflow/ Horizontal Left/Right Two Stage Condensing Gas Fired Furnace 40,000 BTUH S9V2B040U3-SUB-1-EN. February 2016 S9V2B040U3PSAA TAG:

For More Information Click Here or Call General Supply M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

KG6RC Series TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

Upflow/Horizontal Left, Downflow/Horizontal Right Two Stage Condensing Gas-Fired Furnace

Downflow/Horizontal Condensing, Gas-Fired Furnace XB 90 PUB. NO

True performance and rugged durability. TU, LF and LD Models

RG7D 1-Stage Heat Series

FEATURES. Gas Furnace provides the efficiency customers want with 78% Annual Fuel Utilization Efficiency (AFUE).

G6RC Series TECHNICAL SPECIFICATIONS

Upflow/Horizontal 2-Stage, Communicating Variable Speed Gas Furnace Platinum SV

XV80i. Upflow/Horizontal 80% 2-Stage, Variable Speed Gas-Fired Furnace with Whole House Air Cleaner PUB. NO

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Upflow/ Horizontal Downflow/Horizontal Condensing, Direct Vent Gas-Fired Furnace

FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

TUBULAR GAS-FIRED BLOWER STYLE UNIT HEATER

MERIT SERIES Downflow

Submittal. Downflow Two Stage Condensing Gas Fired Furnace 100,000 BTUH S9V2C100D4-SUB-1-EN. March 2016 S9V2C100D4PSAA TAG:

FOR YOUR SAFETY WARNING FOR YOUR SAFETY IMPORTANT CAUTION

Model GB1AAV UPFLOW GAS FURNACE. Series G SS-GB1A-04 FEATURES

TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

Submittal Data DESCRIPTION STANDARD FEATURES. Base Unit. Cabinet. Refrigerant System. Gas Heat

Upflow/ Horizontal Left, Downflow/ Horizontal Right Two Stage Condensing Gas-Fired Furnace XL 90

RGE 13 A T - 1 A

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

Upflow/Horizontal Left Downflow/Horizontal Right Condensing, Direct Vent Gas-Fired Furnace FREEDOM 90 SINGLE STAGE

Direct Gas-Fired Make-Up Air

CATALOG: HVAC - Gas Space Unit Heating

Installation, Operation, and Maintenance

INFRARED RADIANT HEATERS

Direct Fired Heater Model AD Specification

TECHNICAL SPECIFICATIONS

Ruud Achiever Series Multi position Gas Furnaces

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

48TF GAS HEATING/ ELECTRIC COOLING UNITS

SKYPAK II, 3 Ton Series, gives you a

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

13 GEP A L P - 1 A

Upflow/Horizontal Right or Upflow/Horizontal Left Induced Draft Gas Furnace XR 80

FG6T(C,L) Series. High Efficiency / Direct Vent or Non Direct Vent 2-Stage Condensing Gas Furnace with Variable Speed Blower TECHNICAL SPECIFICATIONS

SEPARATED COMBUSTION TUBULAR GAS FIRED DIRECT SPARK PROPELLER UNIT HEATERS

U n i t H e at e r s

Gas-Fired Unit Heaters Commercial & Industrial

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

90 HIGH EFFICIENCY UPFLOW GAS FURNACES

G I E TECHNICAL GUIDE 95.5% AFUE SINGLE STAGE RESIDENTIAL GAS FURNACES MULTI-POSITION MODELS: TG9S DESCRIPTION FEATURES WARRANTY SUMMARY

FORM NO. G REV. 4 Supersedes Form No. G Rev. 3

Transcription:

GTFC-8 HVAC HEATING PRODUCTS Application Manual SF/SC Series TF/TC Series QVSD Series GAS-FIRED HEATING EQUIPMENT Tubular Unit Heaters Duct Furnaces Cabinet Blowers

Contents PAGE GENERAL INFORMATION Tubular 3 APPLICATIONS 4 GG SERIES Standard/Optional Features 5 Unit Number Description 5 Performance Data and Dimensional Data 6 Dimensional Data 7 TF/TC SERIES Standard/Optional Features 8 Unit Number Description 8 Performance and Dimensional Data TF Series 9 Performance and Dimensional Data TC Series 0 Performance Data TC Series SF/SC SERIES Standard/Optional Features 2 Unit Number Description 2 Performance and Dimensional Data SF Series 3 Performance and Dimensional Data SC Series 4 Performance Data SC Series 5 GG Series TF Series GENERAL INFORMATION Duct Furnace 6 QVED/QVES/QVSD SERIES Standard Features 7 Unit Number Description 7 Performance and Dimensional Data QVSD Series 8 Performance and Dimensional Data QVED Series 9 Performance and Dimensional Data QVES Series 9 Dimensional Data QVED/QVES Series 20 CAB SERIES Standard Features 2 Unit Number Description 2 Motor Data 2 Dimensional Data CAB Series 22 Performance Data CAB Series 23 TC Series OPTIONAL ACCESSORIES All Series 24-25 HEAT THROW DATA All Series 26-27 NOZZLE DIMENSIONS 28 TYPICAL STANDARD SPECIFICATIONS GG Series 29 TF/TC Series 29 SF/SC Series 30 QVED/QVES/QVSD Series 30 CAB Series 30 SF Series WARRANTY All Series 3 2 SC Series

Tubular Unit Heaters GG SERIES TF SERIES TC SERIES SF SERIES SC SERIES General Information STERLING TUBULAR DESIGN GAS FIRED UNIT HEATER The Sterling Tubular gas-fired unit heaters offer a highly efficient, extremely durable alternative to the traditional clam shell design. These units combine the latest tubular heat exchanger and inshot burner technology with the quality and reliability you have come to know from Sterling. HIGH EFFICIENCY Standard energy saving features like the direct spark ignition and power venting reduce standby losses and offer improved seasonal efficiencies. Tubular units certified by ETL as providing 83% thermal (combustion) efficiency. TUBULAR HEAT EXCHANGER The Sterling tubular heat exchanger has been designed to provide maximum and uniform heat transfer. The low pressure drop associated with this design enables heated air to be evenly distributed to the conditioned space. This curved, non-welded serpentine design experiences less thermally induced stress making it highly durable for significantly longer service life. All Sterling tubular heat exchangers are constructed of heavy duty 20-gauge aluminized steel. Optional 409 stainless steel heat exchangers are also available. DIRECT SPARK IGNITION SYSTEM Sterling Tubular units utilize a direct spark pilotless ignition of the burner, providing fast heat delivery. This highly reliable and efficient ignition system incorporates an integrated electronic control board to regulate the system sequence of operation, including an onboard LED indicator for simple troubleshooting. VENTING The Sterling Tubular unit heaters are ETL certified in accordance with categories I and III venting requirements. This certification allows units to be vented both vertically and horizontally using either single wall or double wall venting materials. This venting flexibility of the unit heater makes installation easier and more cost effective by allowing the installer to utilize existing venting components. CONTROL ACCESSIBILITY Designed with the service person in mind, every component of the Sterling unit heaters is easily accessible. Ignition and fan controls are located in one centrally located control panel. The access door provides control isolation as well as a pleasing exterior appearance. 0-YEAR WARRANTY Sterling warranties the heat exchanger, flue collector and burners of each unit heater to be free from defects in materials and workmanship for a period of 0 years from the date of manufacture. SEPARATED COMBUSTION - SF/SC SERIES The SF/SC series heater separates the combustion process from the environment where the unit is installed. A power venting system draws a controlled quantity of combustion air from outside the building. The same system exhausts flue products to the outside. The burners, pilot and flue system are enclosed within the unit; thus, the entire combustion process is unaffected by the atmosphere in the space where the heater is located. Separated combustion units are designed to be installed where dusty, dirty or mildly corrosive conditions exist or where high humidity or slightly negative pressure prevail. 3

Applications UNIT HEATER PLACEMENT Gas-fired unit heaters are used primarily in commercial and industrial buildings such as warehouses, manufacturing areas, garages, showrooms, lobbies, etc. Placement is typically determined by air distribution requirements. Proper distributions should have air directed toward areas of greatest heat loss. Multiple units may be used to greatest effect by positioning units around the perimeter. Several units near the center and with air discharging toward outside walls may also satisfy the heating requirements. Direct air discharge on occupants should be avoided. TYPICAL APPLICATIONS A large square area with A narrow area with four A small area with exposed walls and roof; exposed walls either with exposed walls units are blanketing all or without roof exposure. requiring one exposed surfaces. unit. HOW TO CALCULATE HEAT LOSS It is suggested that when calculating heat loss for a building, reference be made to procedures outlined in the ASHRAE Handbook. As an easy reference, however, the following abbreviated method may be used with a good degree of reliability.. Determine inside temperature to be maintained and the design outside temperature for your locality. The difference between these two figures is the design temperature difference. 2. Calculate net areas in square feet of glass, wall, floor, and roof exposed to outside temperature or unheated spaces. Calculate door as all glass. 3. Select heat-transfer coefficients from the table below (or the ASHRAE Handbook) and compute the heat-transmission loss for each area in BTU/HR by multiplying each area by the heat-transfer coefficient and the temperature difference. 4. Add 0% to the heat-loss figures for areas exposed to prevailing winds. 5. Calculate the volume of the room or area in cubic feet and multiply by the estimated number of air changes per hour due to infiltration (usually from one to two). Determine the number of cubic feet per hour of air exhausted by ventilating fans or industrial processes. Substitute the larger of these two figures in the formula to determine the heat required to raise the air from outside to room temperature BTU/HR = cubic feet per hour x temperature difference 55 6. The totals of BTU/HR losses from 3, 4 and 5 (above) will give the total BTU/HR to be supplied by unit heaters. (Note: If processes performed in the room liberate considerable amounts of heat, this may be determined as accurately as possible and subtracted from the total). "U" Building Material Factor WALLS Poured concrete 80#/cu. ft. 8-inch... 0.25 2-inch... 0.8 Concrete Block, hollow cinder aggregate 8-inch... 0.39 2-inch... 0.36 Gravel aggregate 8-inch... 0.52 2-inch... 0.47 Concrete Block, w/4-inch facebrick Gravel, 8-inch... 0.4 Cinder, 8-inch... 0.33 Metal (un-insulated)....7 w/-inch blanket insulation... 0.22 w/3-inch blanket insulation... 0.08 ROOFING Corrugated Metal (un-insulated)....50 w/-inch bolt or blanket... 0.23 w/ / 2 -inch bolt or blanket... 0.6 w/3-inch bolt or blanket... 0.08 Flat Metal w/ 3 / 8 -inch built-up roofing... 0.90 w/-inch blanket insulation under deck... 0.2 w/2-inch blanket insulation under deck... 0.2 Wood/ " / (un-insulated) w/ 3 / 8 -inch built-up roofing... 0.48 w/-inch blanket insulation... 0.7 Wood/ 2" / (un-insulated) w/ 3 / 8 -inch built-up roofing... 0.32 w/-inch blanket insulation... 0.5 Concrete slab/ 2" / (un-insulated) w/ 3 / 8 -inch built-up roofing... 0.30 w/-inch insulation board... 0.6 Concrete slab/ 3" / (un-insulated) w/ 3 / 8 -inch built-up roofing... 0.23 w/-inch insulation board... 0.4 Gypsum slab/ 2" / (un-insulated) w/ / 2 -inch gypsum board... 0.36 w/-inch insulation board... 0.20 Gypsum slab/ 3" / (Un-insulated) w/ / 2 -inch gypsum board... 0.30 w/-inch insulation board... 0.8 WINDOWS Vertical, single-glass....3 Vertical, double-glass, 3 / 6 - inch air space... 0.69 Horizontal, single-glass (sky light).40 DOORS Metal single sheet....20 Wood, -inch... 0.64 2-inch... 0.43 4

GG Series Low Profile Unit Heater RESIDENTIAL AND COMMERCIAL CERTIFICATIONS The Sterling GG Series unit heater conforms with the latest ETL certification standards. Design certified under ANSI Z83.8 for Industrial/Commercial use and the more demanding requirements of CSA 0.96 USA (2nd ed.) Unit Heaters for Residential Installation, make this low profile unit heater the ideal selection. STANDARD FEATURES 82+% Thermal Efficiency Redundant Single-Stage Gas Valve Residential Certification 20/24V Control Transformer OSHA Fan Guard OPTIONAL FEATURES 409 Stainless Steel Heat Exchanger Two-Stage Gas Control (Sizes 60-20 Only) Stainless Steel Flue Collector Unit Number Description 5//60 Fan Motor with Internal Overload Protection Direct Spark Ignition 20-Gauge Cabinet with Baked Enamel Finish 0 Year Heat Exchanger Warranty Supply Voltage (Field Mounted Transformers): 208//60 230//60 208/3/60 230/3/60 460/3/60 575/3/60 Right Hand Control Access - Field Convertible to Left Hand High Limit Switch Air Pressure Switch Natural or Propane Gas Gas Conversion Kit Included Vent Caps Totally Enclosed Motors (Sizes 60-20 Only) Pressure Regulator ( 2 psi) Single & Two- Stage Mercury Free Thermostats Field Convertible to Separated Combustion Easy Access Control Panel 32 Stainless Steel Burner Box 20-Gauge Aluminized Heat Exchanger Power Vented Line Volt Thermostat Locking Thermostat Cover 24V SPST Relay Concentric Vent Kits (For All Separated Combustion Installations) Digit G X X X 2 3 4 5 6 7 8 9 0 2 3 4 5 + Item Prefix UT CA FT FM GT AL GC SV MT DL AS (Internal use Only), 2 - Unit Type [UT] GG - Residential Low Profile Tubular Propeller Note: Field conversion to Separated Combustion requires a Combustion Air Inlet Kit. See Accessory Options X7-4 and X7-5 for proper unit selection. 3, 4, 5 - Capacity [CA] 030-30,000 BTU/HR 045-45,000 BTU/HR 060-60,000 BTU/HR 075-75,000 BTU/HR 090-90,000 BTU/HR 05-05,000 BTU/HR 20-20,000 BTU/HR 6 - Furnace Type [FT] A - Right Hand Access 7 - Furnace Material [FM]* - Standard (Aluminized) Steel 2-409 Stainless Steel *Heat exchanger tube material only. 8 - Gas Type [GT] N - Natural Gas P - Propane (LP) Gas 9 - Altitude [AL] S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Gas Control [GC] A - Single Stage (Standard) B - Two Stage (Capacities [CA] 060 through 20 only) - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Other Note: Supply Voltage [SV] 2-7 include field mounted step down transformer. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed (Capacities [CA] 060 through 20 only) 3 - Development Level [DL] C - Production Onset 4, 5+ - Accessories [AS] FACTORY INSTALLED S3 - Stainless Steel Flue Collector Z - Special All Accessories are to be entered as a separate line item using catalog number which places AS as a prefix. i.e: A7 becomes AS-A7. FIELD INSTALLED (AS- ) A7 - Pressure Regulator -2 psi G - -Stage T87K Mercury Free Thermostat w/subbase Kit G2 - -Stage T87K Mercury Free Thermostat w/tg5a Guard Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G8 - -Stage T669C Line Voltage Thermostat w/subbase G9 - -Stage T822K Mercury Free Thermostat P5-24V SPST Relay-Specify Purpose VC-4-4" Vent Cap X2-30 Degree Downturn Nozzle X7-4 - Combustion Air Inlet Kit (Capacities [CA] 030-075) X3-60 Degree Downturn Nozzle X7-5 - Combustion Air Inlet Kit (Capacities [CA] 090-20) X4-90 Degree Downturn Nozzle 5

CM GG Series Low Profile Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 30 45 60 75 90 05 20 PERFORMANCE DATA Input - BTU/Hr 30,000 45,000 60,000 75,000 90,000 05,000 20,000 (kw) (8.8) (3.2) (7.6) (22.0) (26.4) (30.8) (35.2) Output - BTU/Hr 24,900 37,350 49,800 6,500 73,800 86,00 98,400 (kw) (7.2) (0.9) (4.5) (8.0) (2.6) (25.2) (28.8) Thermal Efficiency - % 83 83 83 82 82 82 82 Free Air Delivery - CFM 370 550 740 920,00,300,475 (cu. m/s) (.75) (.260) (.349) (.434) (.59) (.64) (.696) Air Temperature Rise - F 60 60 60 60 60 60 60 ( C) (5) (5) (5) (5) (5) (5) (5) Full Load Amps at 20V 3.0 3.0 4. 4. 6.4 6.4 6.4 Maximum Circuit Ampacity 3.5 3.5 4.8 4.8 7.5 7.5 7.5 MOTOR DATA: Motor HP 0 0 /2 /2 /0 /0 /0 Motor (kw) (0.04) (0.04) (0.06) (0.06) (0.075) (0.075) (0.075) Motor Type SP SP SP SP SP SP SP RPM 650 650 050 050 050 050 050 Motor Amps @ 5V.9.9 2.6 2.6 4.2 4.2 4.2 DIMENSIONAL DATA - Inches (mm) A Jacket Height 2-3/8 2-3/8 5-7/8 5-7/8 22-5/8 22-5/8 22-5/8 (34) (34) (403) (403) (574) (574) (574) B Overall Height 3-/4 3-/4 6-3/6 6-3/6 23-9/6 23-9/6 23-9/6 (337) (337) (427) (427) (598) (598) (598) C Overall Depth 25-7/8 25-7/8 26-3/6 26-3/6 26-3/8 26-3/8 26-3/8 (632) (632) (665) (665) (670) (670) (670) D Center Line Height of Flue* 8-8- 0-3/8 0-3/8 3-5/8 3-5/8 3-5/8 (26) (26) (263) (263) (346) (346) (346) D2 Center Line Height of Air Intake 8-8- 8 8 8-5/8 8-5/8 8-5/8 (26) (26) (203) (203) (29) (29) (29) E Fan Diameter 0 0 4 4 6 6 6 (254) (254) (356) (356) (406) (406) (406) F Discharge Opening Height 0-3/6 0-3/6 4-7/6 4-7/6 2-3/6 2-3/6 2-3/6 (275) (275) (367) (367) (538) (538) (538) G Vent Connection Diameter 4 4 4 4 4 4 4 (02) (02) (02) (02) (02) (02) (02) H Center Line of Flue Connection From Side 7-/4 7-/4 7-/4 7-/4 7-7- 7- (84) (84) (84) (84) (97) (97) (97) H2 Center Line of Air Intake From Side 2-2- 2-2- 3-3- 3- (70) (70) (70) (70) (89) (89) (89) VENT SIZE REQUIREMENTS - STANDARD COMBUSTION Category III Horizontal - Inches (mm) 4 4 4 4 4 4 4 (02) (02) (02) (02) (02) (02) (02) Category I & III Vertical - Inches (mm) 4 4 4 4 4 4 4 (02) (02) (02) (02) (02) (02) (02) VENT SIZE REQUIRMENTS - SEPARATED COMBUSTION Exhaust Diameter** - Inches (mm) 4 4 4 4 5 5 5 (02) (02) (02) (02) (27) (27) (27) Intake Air Diameter - Inches (mm) 4 4 4 4 5 5 5 (02) (02) (02) (02) (27) (27) (27) Unit Weight - Lbs 60 65 80 85 95 05 0 (kgs) (27) (29) (36) (39) (43) (48) (50) Shipping Weight - Lbs 70 75 90 95 0 5 20 (kgs) (32) (34) (4) (43) (50) (52) (54) *For all installations, the flue collar is included with the unit and should be field installed per the instructions included with the unit. **4-5" reducer supplied where required. Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be field derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be field derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. See unit installation, operation and maintenance manual for deration information. 6

GG Series Low Profile Unit Heater Dimensional Data DIMENSIONS.XXX STANDARD UNITS DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS 7

TF/TC Series Tubular Unit Heater STANDARD FEATURES In-Shot Burner Main Control Design Panel 20-Gauge Steel Jacket with Baked Enamel Finish 5//60 Supply Voltage Direct Spark Ignition OPTIONAL FEATURES Stainless Steel Supply Voltages: Heat Exchanger, 208 & 230//60 Burners and/or and 230, 460, Flue Collector 575/3/60 Redundant Single-Stage Gas Valve 5/24 Volt Control Transformer Premium Efficiency Blower Motors in ODP and TE Types Individually Adjustable and Removable Louvers Power Vented Two-Stage and Various Electronic Modulation Gas Controls 5//60 Volt Motor with Internal Overload Protection Discharge Nozzles (30, 60 & 90 ) or Duct Flange Assembly 0 Year Heat Exchanger, Flue Collector and Burner Warranty 82+% Thermal Efficiency Unit Number Description TF Series Digit T X X X 2 3 4 5 6 7 8 9 0 2 3 + Item Prefix UT CA FT FM GT AL GC SV MT AS (Internal use Only) TC Series Digit T X X X 2 3 4 5 6 7 8 9 0 2 3 4 + Item Prefix UT CA FT FM GT AL GC SV MT MS AS (Internal use Only), 2 - Unit Type [UT] TF - Tubular Propeller TC - Tubular Blower 3, 4, 5 - Capacity [CA] 00-00,000 BTU/HR 25-25,000 BTU/HR 50-50,000 BTU/HR 75-75,000 BTU/HR 200-200,000 BTU/HR 250-250,000 BTU/HR 300-300,000 BTU/HR 350-350,000 BTU/HR 400-400,000 BTU/HR 6 - Furnace Type [FT] A - Right Side Access 7 - Heat Exchanger Construction Material [FM] - Standard (Aluminized) Steel 2-409 Stainless Steel 8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) 9 - Altitude [AL] S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Direct Spark Gas Control [GC] - Single Stage 2 - Two Stage 3 - Electronic Modulation w/room Sensing 4 - Electronic Modulation w/duct Sensing 5 - Electronic Modulation w/duct Sensing & Room Ovrd. Stat 6 - Electronic Modulation w/external 4-20 ma Input 7 - Electronic Modulation w/external 0-0 VDC Input - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Special Note: Supply Voltages [SV] 2-7 include step down transformer. Field mounted for propeller units, factory mounted for blower units. 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed 3 - Premium Efficiency, Open Drip Proof (Blowers only) 4 - Premium Efficiency, Totally Enclosed (Blowers only) 3 - Blower Motor Sizes [MS]** A - /4 HP w/contactor L - HP C - HP w/contactor P - HP w/magnetic Starter D - HP w/contactor R - HP w/magnetic Starter F - HP w/contactor S - HP w/magnetic Starter G - - HP w/contactor T - - HP w/magnetic Starter H - 2 HP w/contactor U - 2 HP w/magnetic Starter J - /4 HP W - /4 HP w/magnetic Starter **Notes:. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard. 2. All single phase units [SV =, 2, 3] include a contactor for units equipped with HP. motor or higher [MS =D, F, G, H] 3. [MS] options J, L only available with [SV] option (5//60). 3/4 - Accessories [AS] FACTORY INSTALLED M6 - OSHA Type Fan Guard (Propellers only) M8 - Discharge Duct Flange Assembly (Blowers only) P4 - Terminal Block Wiring P6 - Summer/Winter Switch S3-409 Stainless Steel Flue Collector S5-304L Stainless Steel Burners FIELD INSTALLED (AS- ) All Accessories are to be entered as a separate line item using catalog number which utilizes AS as a prefi x. i.e: A7 becomes AS-A7. A7 - Pressure Regulator -2 psi M2-2 - Vent Caps (5") (Unit Capacity 00-250) M2-3 - Vent Caps (6") (Unit Capacity 300-400) F - -Stage T675A Ductstat M7-2 to 4 Point Suspension Kit (Propeller Only) F2-2-Stage T678A Ductstat P5-24V SPST Relay-Specify Purpose G - -Stage T87K Mercury Free Thermostat w/subase Kit X2-30 Degree Downturn Nozzle G2 - -Stage T87K Mercury Free Thermostat X3-60 Degree Downturn Nozzle w/tg5a Guard Kit X4-90 Degree Downturn Nozzle G3 - -Stage T834N Mercury Free X5 - Vertical Louver Kit Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G8 - -Stage T669C Line Voltage Stat w/subbase G9 - -Stage T822K Mercury Free Thermostat 8

CM TF Series Tubular Propeller Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (43.9) (5.2) (58.6) (73.2) (87.8) (02.5) (7.) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 249,000 290,500 332,000 (kw) (24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.) (97.2) Thermal Efficiency - % 83 83 83 83 83 83 83 83 83 Free Air Delivery - CFM,600 2,200 2,400 2,850 3,200 3,450 5,000 5,600 5,800 (cu. m/s) (0.756) (.039) (.33) (.346) (.5) (.629) (2.36) (2.644) (2.738) Air Temperature Rise - F 47 42 47 46 47 54 45 47 5 ( C) (26) (23) (26) (26) (26) (30) (24) (26) (28) Full Load Amps at 20V 5.3 5.8 5.8 8.0 8.0 8.0.3 3.5 3.5 MOTOR DATA: Motor HP (Qty.) /0 /4 /4 /3 /3 /3 (2) /4 (2) /3 (2) /3 Motor kw (0.080) (0.9) (0.9) (0.25) (0.25) (0.25) (0.9) (0.25) (0.25) Motor Type** SP PSC PSC PSC PSC PSC PSC PSC PSC RPM,50,40,40,40,40,40,40,40,40 Amps @ 5V 4.7 4.7 4.7 5.8 5.8 5.8 9.4.6.6 DIMENSIONAL DATA - Inches (mm) A Overall Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) B Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (83) (83) (83) (289) (289) (289) C Width to CL Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) D Depth to Rear of Housing 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) E Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) F Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) G Depth to CL Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) H Discharge Opening Height 24-24- 24-24- 24-24- 24-24- 24- (622) (622) (622) (622) (622) (622) (622) (622) (622) L Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) *Vent Size Diameter - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Fan Diameter - Inches (Qty.) 6 6 6 8 8 8 (2) 6 (2) 8 (2) 8 Gas Inlet-Natural Gas (Inches) Gas Inlet- LP Gas (Inches) OR OR OR OR Approximate Unit Weight - Lbs 33 45 55 9 20 2 307 32 335 (kg) (60) (66) (70) (87) (9) (96) (39) (45) (52) Approximate Ship Weight - Lbs 73 85 95 24 25 26 367 38 395 (kg) (78) (84) (88) (09) (4) (8) (66) (73) (79) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be field derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be field derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. See unit installation, operation and maintenance manual for deration information. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SP = SHADED POLE PSC = PERMANENT SPLIT CAPACITOR -3/8" (35) (Hanging) C E (Hanging) Flue * D G -5/8" (295) (Hanging) 32-" (826) L B H (Discharge Opening) 33" A D467 DIMENSIONS.XXX STANDARD UNITS DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS D467 Electrical Control Panel Gas Valve F (Discharge Opening) Rear View Side View Front View " (25) 9

CM TC Series Tubular Blower Unit Heater Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (73.3) (87.9) (02.6) (7.2) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 246,000 290,500 332,000 (kw) (24.3) (30.4) (36.5) (42.6) (48.6) (60.8) (72.) (85.) (97.3) Thermal Efficiency - % 83 83 83 83 83 83 82 83 83 Free Air Delivery - CFM,8,476,77 2,067 2,362 2,953 3,50 4,34 4,724 (cu. m/s) (0.557) (0.697) (0.836) (0.976) (.5) (.394) (.652) (.95) (2.230) Air Temperature Rise - F 65 65 65 65 65 65 65 65 65 ( C) (36) (36) (36) (36) (36) (36) (36) (36) (36) Outlet Velocity - FPM 370 463 555 395.0 45.0 564.0 422 498 570 (m/s) (.879) (2.35) (2.89) (2.006) (2.29) (2.864) (2.43) (2.529) (2.895) Full Load Amps at 5V 7.3 9.4 9.4 4.2 4.2 5.6 5.6 20.8 20.8 Maximum Circuit Ampacity 8.6.2.2 7. 7. 8.9 8.9 25.4 25.4 MOTOR DATA Motor HP /4 - - Motor kw 0.9 0.37 0.37 0.56 0.56 0.75 0.75.. Motor Type** SPH SPH SPH SPH SPH Cap. Start Cap. Start Cap. Start Cap. Start RPM,725,725,725,725,725,725,725,725,725 Amps @ 5V 5. 7.2 7.2.6.6 3.0 3.0 8.2 8.2 DIMENSIONAL DATA - Inches (mm) "A" Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (832) (832) (832) (289) (289) (289) "C" Width to Centerline Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Front Hanger 2 2 2 2 2 2 2 2 2 (533) (533) (533) (533) (533) (533) (533) (533) (533) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Hanging Distance Depth 9 9-9- 32-32- 32-23- 32-32- (483) (495) (495) (832) (832) (832) (597) (832) (832) "G" Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) "H" Depth to Centerline Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "L" Discharge Opening Height 24-24- 24-24- 24-24- 24-24- 24- (622) (622) (622) (622) (622) (622) (622) (622) (622) "M" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) "P" Overall Unit Depth 49-49-3/8 49-3/8 56-/8 56-/8 56-/8 53-3/8 56-/8 56-/8 (264) (254) (254) (426) (426) (426) (356) (426) (426) *Vent Size Diameter - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Blower Size - Inches (Qty) 9 0 0 2 2 2 0 (2) 2 (2) 2 (2) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs 7 75 202 245 264 289 370 390 429 (kg) (78) (79) (92) () (20) (3) (68) (77) (95) Approximate Ship Weight - Lbs 256 26 289 38 400 425 520 547 595 (kg) (6) (8) (3) (73) (8) (93) (236) (248) (270) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be field derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be field derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. See unit installation, operation and maintenance manual for deration information. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SPH = SPLIT PHASE CAP. START = CAPACITOR START /8 E C Flue H F 32 D M B 33 L (Discharge Opening) A 0 D893B Electrical Control Panel Gas Valve G (Discharge P Opening) Rear View Side View Front View

TC Series Tubular Blower Unit Heater Performance Data Unit TC00 TC25 TC50 TC75 TC200 TC250 TC300 TC350 TC400 Temp.Rise F ( C) CFM (cu. m/s) External Static Pressure Inches W.C. (kpa) 0." (0.02) 0.2" (0.05) 0.3" (0.07) 0.4" (0.0) 0.5" (0.2) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) 804 860 927 989 045 50 535 (0) (0.724) (0.37) (0.37) (0.37) (0.37) (0.37) 60 279 /4 /4 /4 /4 /4 649 760 82 890 963 (5.5) (0.603) (0.9) (0.9) (0.9) (0.9) (0.9) 70 096 /4 /4 /4 /4 /4 633 700 779 858 920 (2.) (0.57) (0.9) (0.9) (0.9) (0.9) (0.9) 80 959 /4 /4 /4 /4 /4 59 665 733 80 869 (26.6) (0.452) (0.9) (0.9) (0.9) (0.9) (0.9) 50 99 703 758 80 863 98 (0) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 60 599 608 685 74 790 843 (5.5) (0.754) (0.37) (0.37) (0.37) (0.37) (0.37) 70 37 558 626 694 755 798 (2.) (0.647) (0.37) (0.37) (0.37) (0.37) (0.37) 80 99 580 597 649 720 779 (26.6) (0.565) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2303 853 927 962 988 040 (0) (.087) (0.37) (0.37) (0.37) (0.37) (0.37) 60 99 755 80 845 894 939 (5.5) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 70 645 649 726 790 836 876 (2.) (0.776) (0.37) (0.37) (0.37) (0.37) (0.37) 80 439 66 670 720 785 840 (26.6) (0.679) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2687 522 566 62 652 688 (0) (.26) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2239 468 54 564 609 654 (5.5) (.05) (0.56) (0.56) (0.56) (0.56) (0.56) 70 99 423 47 527 582 624 (2.) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 80 697 402 482 55 567 609 (26.6) (0.8) (0.56) (0.56) (0.56) (0.56) (0.56) 50 307 592 627 670 702 748 (0) (.44) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2559 526 56 597 647 688 (5.5) (.2) (0.56) (0.56) (0.56) (0.56) (0.56) 70 293 468 59 556 62 653 (2.) (.03) (0.56) (0.56) (0.56) (0.56) (0.56) 80 99 432 48 537 593 638 (26.6) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 50 3839 734 766 802 836 863 (0) (.8) (0.75) (0.75) (.) (.) (.) 60 399 626 668 700 749 780 (5.5) (.5) (0.75) (0.75) (0.75) (0.75) (0.75) 70 2742 545 593 633 680 78 (2.) (.29) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2399 494 555 590 642 680 (26.6) (.3) (0.75) (0.75) (0.75) (0.75) (0.75) 50 455 734 766 802 836 863 (0) (2.4) (0.75) (0.75) (.) (.) (.) 60 3792 626 668 700 749 780 (5.5) (.79) (0.75) (0.75) (0.75) (0.75) (0.75) 70 3259 545 593 633 680 78 (2.) (.53) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2844 494 555 590 642 680 (26.6) (.34) (0.75) (0.75) (0.75) (0.75) (0.75) 50 5374 558 598 638 676 727 (0) (2.54) (.) (.) (.) (.) (.) 60 4478 484 532 588 653 680 (5.5) (2.) (.) (.) (.) (.) (.) 70 3839 45 503 559 609 654 (2.) (.8) (.) (.) (.) (.) (.) 80 3359 408 480 536 589 62 (26.6) (.59) (.) (.) (.) (.) (.) 50 642 2 647 659 670 73 75 (0) (2.9) (.) (.) (.) (.) (.49) 60 58 553 570 68 653 697 (5.5) (2.4) (.) (.) (.) (.) (.) 70 4387 483 523 568 65 660 (2.) (2.07) (.) (.) (.) (.) (.) 80 3839 437 490 547 589 655 (26.6) (.8) (.) (.) (.) (.) (.)

SF/SC Series Separated Combustion Unit Heater STANDARD FEATURES Enclosed 5/24 Volt Combustion Control System Transformer 20-Gauge Aluminized Steel Tubular Heat Exchanger 83% Thermal Efficiency Combustion Air Pressure Switch OPTIONAL FEATURES Stainless Steel Supply Voltages: Heat Exchanger, 208 & 230//60 Burners, and/or and 208, 230, Flue Collector 460, 575/3/60 ODP Motor (with Overload Protection) Redundant Single-Stage Gas Valve Two-Stage and Various Electronic Modulation Gas Controls Unit Number Description 20-Gauge Steel Cabinetry with Baked Enamel Finish Direct Spark Ignition System 5//60 Supply Voltage Premium Efficiency Blower Motors in ODP & TE Types Digit T X X X 2 3 4 5 6 7 8 9 0 2 3 4 + Item Prefix UT CA FT FM GT AL GC SV MT MS AS (Internal use Only) Rear Burner Access Power Vented Individually Adjustable and Removable Horizontal Louvers Discharge Nozzles (30, 60 & 90 ) or Duct Flange Assembly Complete Belt /Fan Guard Main Control Panel 0 Year Heat Exchanger, Flue Collector and Burner Warranty Combustion Air Inlet Kits (allows concentric venting with horizontal or vertical termination), 2 - Unit Type [UT] SF - Separated Combustion Tubular Propeller SC - Separated Combustion Tubular Blower 3, 4, 5 - Capacity [CA] 00-00,000 BTU/HR 25-25,000 BTU/HR 50-50,000 BTU/HR 75-75,000 BTU/HR 200-200,000 BTU/HR 250-250,000 BTU/HR 300-300,000 BTU/HR 350-350,000 BTU/HR 400-400,000 BTU/HR 6 - Furnace Type [FT] A - Right Side Access 7 - Heat Exchanger Construction Material [FM] - Standard (Aluminized) Steel 2-409 Stainless Steel 8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) 9 - Altitude [AL] S - 0 4,999 ft. T - 5,000,999 ft. Note: Installations over 2,000 ft. require gas input deration in the field. Refer to unit installation instructions. 0 - Direct Spark Gas Control [GC] - Single Stage 2 - Two Stage 3 - Electronic Modulation w/room Sensing 4 - Electronic Modulation w/duct Sensing 5 - Electronic Modulation w/duct Sensing & Room Ovrd. Stat 6 - Electronic Modulation w/external 4-20 ma Input 7 - Electronic Modulation w/external 0-0 VDC Input - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Special Note: Supply Voltages [SV] 2-7 include step down transformer. Field mounted for propeller units, factory mounted for blower units. 2 2 - Motor Type [MT] - Open Drip Proof (Standard) 2 - Totally Enclosed 3 - Premium Efficiency, Open Drip Proof (Blowers Only) 4 - Premium Efficiency, Totally Enclosed (Blowers Only) 3 - Blower Motor Sizes [MS]** A - /4 HP w/contactor P - HP w/magnetic Starter C - HP w/contactor R - HP w/magnetic Starter D - HP w/contactor S - HP w/magnetic Starter F - HP w/contactor T - - HP w/magnetic Starter G - - HP w/contactor U - 2 HP w/magnetic Starter H - 2 HP w/contactor W - /4 HP w/magnetic Starter J - /4 HP 0 - None/Not Applicable L - HP **Notes:. All 3-phase units [SV = 4, 5, 6, 7] include a contactor as standard. 2. All single phase units [SV =, 2, 3] include a contactor for units equipped with HP. motor or higher [MS =D, F, G, H] 3. [MS] options J, L only available with [SV] option (5//60). 4 - Accessories [AS] FACTORY INSTALLED M6 - OSHA Type Fan Guard (Propellers Only) M8 - Discharge Duct Flange (Blowers Only) P4 - Terminal Block Wiring P6 - Summer/Winter Switch S3-409 Stainless Steel Flue Collector S5-304L Stainless Steel Burners FIELD INSTALLED (AS- ) All Accessories are to be entered as a separate line item using catalog number which utilizes AS as a prefi x. i.e: A7 becomes AS-A7. A7 - Pressure Regulator -2 psi M2-2 - Vent Caps (5") (Unit Capacity 00-250) M2-3 - Vent Caps (6") (Unit Capacity 300-400) F - -Stage T675A Ductstat (Blowers Only) M7-2 to 4 Point Suspension Kit (Propellers Only) F2-2-Stage T678A Ductstat (Blowers Only) P5-24V SPST Relay-Specify Purpose G - -Stage T87K Mercury Free Thermostat w/subase Kit X2-30 Degree Downturn Nozzle G2 - -Stage T87K Mercury Free Thermostat X3-60 Degree Downturn Nozzle w/tg5a Guard Kit X4-90 Degree Downturn Nozzle G3 - -Stage T834N Mercury Free X5 - Vertical Louver Kit Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free X7-H5 - Horiz. Combustion Air Inlet Kit, 5 inch Thermostat w/subbase (Unit Capacity 00-250) G6 - Locking Thermostat Cover X7-H6 - Horiz. Combustion Air Inlet Kit, 6 inch G8 - -Stage T669C Line Voltage Stat (Unit Capacity 300-400) w/subbase X7-V5 - Vert. Combustion Air Inlet Kit, 5 inch G9 - -Stage T822K Mercury Free (Unit Capacity 00-250) Thermostat X7-V6 - Vert. Combustion Air Inlet Kit, 6 inch (Unit Capacity 300-400)

CM SF Series Separated Combustion Propeller Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (43.9) (5.2) (58.6) (73.2) (87.8) (02.5) (7.) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 249,000 290,500 332,000 (kw) (24.3) (30.4) (36.4) (42.5) (48.6) (60.7) (72.9) (85.) (97.2) Thermal Efficiency - % 83 83 83 83 83 83 83 83 83 Free Air Delivery - CFM,600 2,200 2,400 2,850 3,200 3,450 5,000 5,600 5,800 (cu. m/s) (0.756) (.039) (.33) (.346) (.5) (.629) (2.36) (2.644) (2.738) Air Temperature Rise - F 47 42 47 46 47 54 45 47 5 ( C) (26) (23) (26) (26) (26) (30) (24) (26) (28) Full Load Amps at 20V 6.4 6.9 6.9 8.0 8.0 8.0.3 3.5 3.5 MOTOR DATA: Motor HP (Qty) /0 /4 /4 /3 /3 /3 /4 (2) /3 (2) /3 (2) Motor kw (0.080) (0.9) (0.9) (0.25) (0.25) (0.25) (0.9) (0.25) (0.25) Motor Type** SP PSC PSC PSC PSC PSC PSC PSC PSC RPM,050,40,40,40,40,40,40,40,40 Amps @ 5V 4.2 4.7 4.7 5.8 5.8 5.8 9.4.6.6 DIMENSIONAL DATA - Inches (mm) "A" Overall Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (83) (83) (83) (289) (289) (289) "C" Width to CL Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Rear of Housing 2-/4 2-/4 2-/4 (279) (279) (279) (279) (279) (279) (3) (3) (3) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) "G" Depth to CL Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "L" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) "M" Vent Size Diameter* - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs 35 47 57 94 204 24 3 325 339 (kg) (6) (67) (7) (88) (93) (97) (4) (47) (54) Approximate Ship Weight - Lbs 75 87 97 244 254 264 37 385 399 (kg) (79) (85) (89) () (5) (20) (68) (75) (8) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be field derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be field derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. See unit installation, operation and maintenance manual for deration information. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SP = SHADED POLE PSC = PERMANENT SPLIT CAPACITOR -3/8' (35mm) (Hanging) E (Hanging) C M (Flue Diameter) D G -5/8 (295mm) (Hanging) 32-' (826mm) L B 33" (838mm) 24- (622mm) (Discharge Opening) A Combustion Air Inlet Electrical Control Panel Gas Valve Connection High Limit Access F (Discharge Opening) Rear View Side View Front View " (25mm) D9067B 3

CM SC Series Separated Combustion Blower Performance and Dimensional Data INTERTEK VERIFIED ENERGY PERFORMANCE VERIFIED RENDEMENT ENERGETIQUE VERIFIE UNIT CAPACITY (MBH) 00 25 50 75 200 250 300 350 400 PERFORMANCE DATA Input - BTU/Hr 00,000 25,000 50,000 75,000 200,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (73.3) (87.9) (02.6) (7.2) Output - BTU/Hr 83,000 03,750 24,500 45,250 66,000 207,500 246,000 290,500 332,000 (kw) (24.3) (30.4) (36.5) (42.6) (48.6) (60.8) (72.) (85.) (97.3) Thermal Efficiency - % 83 83 83 83 83 83 82 83 83 Free Air Delivery - CFM,8,476,77 2,067 2,362 2,953 3,50 4,34 4,724 (cu. m/s) (0.557) (0.697) (0.836) (0.976) (.5) (.394) (.652) (.95) (2.230) Air Temperature Rise - F 65 65 65 65 65 65 65 65 65 ( C) (36) (36) (36) (36) (36) (36) (36) (36) (36) Outlet Velocity - FPM 370 463 555 395.0 45.0 564.0 422 498 570 (m/s) (.879) (2.35) (2.89) (2.006) (2.29) (2.864) (2.43) (2.529) (2.895) Full Load Amps at 5V 7.3 9.4 9.4 4.2 4.2 5.6 5.6 20.8 20.8 Maximum Circuit Ampacity 8.6.2.2 7. 7. 8.9 8.9 25.4 25.4 MOTOR DATA: Motor HP /4 - - Motor kw 0.9 0.37 0.37 0.56 0.56 0.75 0.75.. Motor Type** SPH SPH SPH SPH SPH Cap. Start Cap. Start Cap. Start Cap. Start RPM,725,725,725,725,725,725,725,725,725 Amps @ 5V 5. 7.2 7.2.6.6 3.0 3.0 8.2 8.2 DIMENSIONAL DATA - Inches (mm) "A" Height to Top of Flue 33-33- 33-33- 33-33- 34 34 34 (857) (857) (857) (857) (857) (857) (864) (864) (864) "B" Jacket Width of Unit 20-20- 20-32- 32-32- 50-50- 50- (527) (527) (527) (832) (832) (832) (289) (289) (289) "C" Width to Centerline Flue 3-3/8 3-3/8 3-3/8 9-3/8 9-3/8 9-3/8 28-3/8 28-3/8 28-3/8 (340) (340) (340) (492) (492) (492) (72) (72) (72) "D" Depth to Front Hanger 2 2 2 2 2 2 2 2 2 (533) (533) (533) (533) (533) (533) (533) (533) (533) "E" Hanging Distance Width 8-5/8 8-5/8 8-5/8 30-5/8 30-5/8 30-5/8 48-5/8 48-5/8 48-5/8 (473) (473) (473) (778) (778) (778) (235) (235) (235) "F" Hanging Distance Depth 9 9-9- 32-32- 32-23- 32-32- (483) (495) (495) (832) (832) (832) (597) (832) (832) "G" Discharge Opening Width 8-8- 8-30- 30-30- 48-48- 48- (476) (476) (476) (78) (78) (78) (238) (238) (238) "H" Depth to Centerline Flue 4-4- 4-4- 4-4- 5-/8 5-/8 5-/8 (2) (2) (2) (2) (2) (2) (30) (30) (30) "M" Overall Unit Width 25-/4 25-/4 25-/4 37-/4 37-/4 37-/4 55-/4 55-/4 55-/4 (64) (64) (64) (946) (946) (946) (403) (403) (403) "P" Overall Unit Depth 49-49-3/8 49-3/8 56-/8 56-/8 56-/8 53-3/8 56-/8 56-/8 (264) (254) (254) (426) (426) (426) (356) (426) (426) *Vent Size Diameter - Inches 5 5 5 5 5 5 6 6 6 (mm) (27) (27) (27) (27) (27) (27) (52) (52) (52) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches OR OR OR OR Approximate Unit Weight - Lbs 73 77 204 248 267 292 374 394 433 (kg) (78) (80) (92) (2) (2) (32) (70) (79) (96) Approximate Ship Weight - Lbs 258 263 29 384 403 428 524 55 599 (kg) (7) (9) (32) (74) (83) (94) (238) (250) (272) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in USA above 2,000 ft. (60m), the unit input must be field derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (NFPA No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be field derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. See unit installation, operation and maintenance manual for deration information. * Flue collar is factory supplied with unit; to be field installed per included instructions. ** LEGEND: SPH = SPLIT PHASE CAP. START = CAPACITOR START /8 (29mm) C E Flue H 32 (826mm) F D M B 33 (838mm) 24 (622mm) (Discharge Opening) A 4 D9050B Electrical Control Panel Gas Valve G (Discharge Opening) P Rear View Side View Front View

SC Series Separated Combustion Blower Performance Data Unit SC00 SC25 SC50 SC75 SC200 SC250 SC300 SC350 SC400 Temp.Rise F ( C) CFM (cu. m/s) External Static Pressure Inches W.C. (kpa) 0." (0.02) 0.2" (0.05) 0.3" (0.07) 0.4" (0.0) 0.5" (0.2) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) RPM HP (kw) 804 860 927 989 045 50 535 (0) (0.724) (0.37) (0.37) (0.37) (0.37) (0.37) 60 279 /4 /4 /4 /4 /4 649 760 82 890 963 (5.5) (0.603) (0.9) (0.9) (0.9) (0.9) (0.9) 70 096 /4 /4 /4 /4 /4 633 700 779 858 920 (2.) (0.57) (0.9) (0.9) (0.9) (0.9) (0.9) 80 959 /4 /4 /4 /4 /4 59 665 733 80 869 (26.6) (0.452) (0.9) (0.9) (0.9) (0.9) (0.9) 50 99 703 758 80 863 98 (0) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 60 599 608 685 74 790 843 (5.5) (0.754) (0.37) (0.37) (0.37) (0.37) (0.37) 70 37 558 626 694 755 798 (2.) (0.647) (0.37) (0.37) (0.37) (0.37) (0.37) 80 99 580 597 649 720 779 (26.6) (0.565) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2303 853 927 962 988 040 (0) (.087) (0.37) (0.37) (0.37) (0.37) (0.37) 60 99 755 80 845 894 939 (5.5) (0.905) (0.37) (0.37) (0.37) (0.37) (0.37) 70 645 649 726 790 836 876 (2.) (0.776) (0.37) (0.37) (0.37) (0.37) (0.37) 80 439 66 670 720 785 840 (26.6) (0.679) (0.37) (0.37) (0.37) (0.37) (0.37) 50 2687 522 566 62 652 688 (0) (.26) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2239 468 54 564 609 654 (5.5) (.05) (0.56) (0.56) (0.56) (0.56) (0.56) 70 99 423 47 527 582 624 (2.) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 80 697 402 482 55 567 609 (26.6) (0.8) (0.56) (0.56) (0.56) (0.56) (0.56) 50 307 592 627 670 702 748 (0) (.44) (0.56) (0.56) (0.56) (0.56) (0.56) 60 2559 526 56 597 647 688 (5.5) (.2) (0.56) (0.56) (0.56) (0.56) (0.56) 70 293 468 59 556 62 653 (2.) (.03) (0.56) (0.56) (0.56) (0.56) (0.56) 80 99 432 48 537 593 638 (26.6) (0.905) (0.56) (0.56) (0.56) (0.56) (0.56) 50 3839 734 766 802 836 863 (0) (.8) (0.75) (0.75) (.) (.) (.) 60 399 626 668 700 749 780 (5.5) (.5) (0.75) (0.75) (0.75) (0.75) (0.75) 70 2742 545 593 633 680 78 (2.) (.29) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2399 494 555 590 642 680 (26.6) (.3) (0.75) (0.75) (0.75) (0.75) (0.75) 50 455 734 766 802 836 863 (0) (2.4) (0.75) (0.75) (.) (.) (.) 60 3792 626 668 700 749 780 (5.5) (.79) (0.75) (0.75) (0.75) (0.75) (0.75) 70 3259 545 593 633 680 78 (2.) (.53) (0.75) (0.75) (0.75) (0.75) (0.75) 80 2844 494 555 590 642 680 (26.6) (.34) (0.75) (0.75) (0.75) (0.75) (0.75) 50 5374 558 598 638 676 727 (0) (2.54) (.) (.) (.) (.) (.) 60 4478 484 532 588 653 680 (5.5) (2.) (.) (.) (.) (.) (.) 70 3839 45 503 559 609 654 (2.) (.8) (.) (.) (.) (.) (.) 80 3359 408 480 536 589 62 (26.6) (.59) (.) (.) (.) (.) (.) 50 642 2 647 659 670 73 75 (0) (2.9) (.) (.) (.) (.) (.49) 60 58 553 570 68 653 697 (5.5) (2.4) (.) (.) (.) (.) (.) 70 4387 483 523 568 65 660 (2.) (2.07) (.) (.) (.) (.) (.) 80 3839 437 490 547 589 655 (26.6) (.8) (.) (.) (.) (.) (.) 5

Duct Furnaces QVED SERIES QVES SERIES QVSD SERIES Indoor Duct Furnace Sterling HVAC s line of high efficient indoor duct furnaces are designed for ducted air applications. Indoor duct furnaces are designed for use with existing systems for heating, heating / cooling or make-up air systems. Sterling s indoor duct furnaces are available in 0 sizes (00 400 MBH) and equipped with electronic spark ignition (00% safety shutoff on LP models), 5 volt power, vent system pressure switch, high limit switch and 24 volt control transformer. QVED/QVES Series All duct furnaces are ETL certified for installation upstream or downstream from cooling coils (stainless steel heat exchangers are recommended). Sterling HVAC s products are proudly manufactured in the USA. HEAT EXCHANGERS All heat exchangers feature 20-gauge tubes and 8-gauge headers and are available in 3 types of steel: Aluminized Steel (Standard) 409 Grade Stainless Steel (Optional) 32 Grade Stainless Steel (Optional) Stainless steel heat exchangers recommended for applications where entering air is below 40 F (4.4 C) and/or duct furnaces are located downstream from cooling coils. QVSD Series APPLICATIONS Sterling s duct furnaces are available in variable configurations to meet all application needs. QVED (bottom burner access) and QVES (side burner access) models offer integral power venting through a concentric vent for both outside combustion air and flue gas exhaust. The QVSD (separated combustion) is designed to be installed in dusty, dirty or mildly corrosive environments, or where high humidity or slightly negative pressures exist. All critical components including the burners, pilot and flue systems are fully enclosed within the unit and protected from the elements insuring clean and efficient combustion. QVSD units are perfect for manufacturing and automotive facilities and greenhouse applications. 6

QVED/QVES Series Power Vented Duct Furnace QVSD Seperated Combustion Duct Furnace STANDARD FEATURES QVED Bottom Access Panel QVES Side Access Panel, Right Side QVSD Separated Combustion 80% Thermal Efficiency Aluminized Steel Heat Exchanger 20-gauge Aluminized Steel Burners with Stainless Burner Shade Port Protector For Natural and Propane Gases Aluminized Steel Flue Collector 5//60 Supply Voltage Spark Ignited Intermittent Pilot with Electronic Flame Supervision Power Venter Redundant Single Stage Combustion Gas Valve High Limit Switch Control Transformer, 5/24V Combustion Air Pressure Switch Adjustable Burner Air Shutters Four Point Suspension QVSD Enclosed Combustion System 20-Gauge Steel Cabinet with Baked Enamel Finish QVSD Combustion Air/ Flue Connections (see Vent Caps; Two Required per Unit) Unit Number Description Digit X X X X 2 3 4 5 6 7 8 9 0 2 3 4 5 + Item Prefix UT CA FT FM GT IC AL GC SV MT MS AS (Internal use Only) Digit #, 2 - Unit Type [UT] QVED (D2) - Power Vented Duct Furnace QVSD (D3) - Separated Combustion Duct Furnace QVES (D6) - Side Service Power Vented Duct Furnace Digit #3, 4, 5 - Capacity [CA] 00-00,000 BTU/HR 225-225,000 BTU/HR 25-25,000 BTU/HR 250-250,000 BTU/HR 50-50,000 BTU/HR 300-300,000 BTU/HR 75-75,000 BTU/HR 350-350,000 BTU/HR 200-200,000 BTU/HR 400-400,000 BTU/HR Digit #6 - Furnace Type [FT] A - Right Side Access (Standard) B - Left Side Access Digit #7 - Heat Exchanger Construction Material [FM] - Aluminized Steel 2-409 Stainless Steel 3-32 Stainless Steel Digit #8 - Gas Type [GT] N - Natural Gas P - Propane Gas (LP) K - Natural Gas w/00% Shutoff Digit #9 - Ignition Control [IC] 2 - Spark Ignition Digit #0 - Altitude [AL] A - 0-,999 ft. J - 8,000-8,999 ft. B - 2,000-2,999 ft. K - 9,000-9,999 ft. C - 3,000-3,999 ft. L - 0,000-0,999 ft. D - 4,000-4,999 ft. M -,000-,999 ft. F - 5,000-5,999 ft. N - Local Gas Supplier Derate G - 6,000-6,999 ft. P - Canadian High Altitude 2,000-4,500 ft. H - 7,000-7,999 ft. Digit # - Gas Control [GC] A - Single Stage B - Two Stage H - Electronic Modulation w/room Sensing J - Electronic Modulation w/duct Sensing K - Electronic Modulation w/duct Sensing & Room Ovrd. Stat L - Electronic Modulation w/external 4-20 ma Input N - Electronic Modulation w/external 0-0 VDC Input Digit #2 - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Special Note: Supply Voltages [SV] 2-7 include field mounted step down transformer. Digit #3 - Motor Type [MT] 0 - None/Not Applicable Digit #4 - Motor Sizes [MS] 0 - None/Not Applicable Digit #5 - Accessories [AS] FACTORY INSTALLED A8 - Input Derate K4 - Fan Time Delay K5 - Air Flow Prove Switch P4 - Terminal Block Wiring P6 - Summer/Winter Switch S - 409 Stainless Steel Burners S3-409 Stainless Steel Flue Collector FIELD INSTALLED (AS- ) Accessories are not included in the Unit Number. All Accessories are entered as a separate line item using the catalog number which utilizes AS as a prefix. i.e: A7 becomes AS-A7. A7 - Pressure Regulator -2 psi M2- - Vent Caps (4") (Unit Capacity 00-75) F - -Stage T675A Ductstat M2-2 - Vent Caps (5") F2-2-Stage T678A Ductstat (Unit Capacity 200-250 M2-3 - Vent Caps (6") G - -Stage T87K (Unit Capacity 300-400) Mercury Free Thermostat M3- - Adaptors (5"-4") w/subbase Kit (Unit Capacity 00-75) G2 - -Stage T87K M4 - Vertical Combustion Air Mercury Free Thermostat Inlet Kit w/tg5a Guard Kit M5 - Horizontal Combustion Air G3 - -Stage T834N Mercury Free Inlet Kit Thermostat w/fan Switch G6 - Locking Thermostat Cover P2 - Adjustable G8 - -Stage T669C High Limit Switch Line Voltage Stat w/subbase P3 - Adjustable Fan Switch G9 - -Stage T822K P5-24V SPST Relay- Mercury Free Thermostat Specify Purpose H5 - Low Ambient Control Q7 - Horizontal/Vertical Louvers S4-409 Stainless Drip Pan (Only available on QVED and QVES) 7

QVSD Series Separated Combustion Duct Furnace Performance and Dimensional Data UNIT CAPACITY (MBH) 00 25 50 75 200 225 250 300 350 400 PERFORMANCE DATA Input (Maximum) - BTU/Hr. 00,000 25,000 50,000 75,000 200,000 225,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (65.9) (73.3) (87.9) (02.6) (7.2) Input (Minimum) - BTU/Hr. 50,000 62,500 75,000 87,500 00,000 2,500 25,000 50,000 75,000 200,000 (kw) (4.6) (8.3) (22.0) (25.6) (29.3) (33.0) (36.6) (44.0) (5.3) (58.6) Output - BTU/Hr. 80,000 00,000 20,000 40,000 60,000 80,000 200,000 240,000 280,000 320,000 (kw) (23.4) (29.3) (35.) (4.0) (46.9) (52.7) (58.6) (70.3) (82.0) (93.7) Thermal Efficiency - % 80 80 80 80 80 80 80 80 80 80 Free Air Delivery (Minimum) - CFM 822,028,233,439,645,850 2,056 2,467 2,878 3,289 (cu. m/s) (0.388) (0.485) (0.582) (0.679) (0.776) (0.873) (0.970) (.64) (.358) (.552) Air Temperature Rise - F 90 90 90 90 90 90 90 90 90 90 ( C) (50) (50) (50) (50) (50) (50) (50) (50) (50) (50) Pressure Drop - Inches W.C. 0.0 0.09 0.09 0.09 0.09 0.09 0.09 0.0 0.0 0.0 (kpa) (0.02) (0.02) (0.02) (0.02) (0.02) (0.02) (0.02) (0.02) (0.02) (0.02) Free Air Delivery (Maximum) - CFM 3,700 4,625 5,550 6,475 7,40 8,326 9,25,0 2,95 4,80 (cu. m/s) (.746) (2.83) (2.620) (3.056) (3.493) (3.930) (4.366) (5.240) (6.3) (6.986) Air Temperature Rise - F 20 20 20 20 20 20 20 20 20 20 ( C) () () () () () () () () () () Pressure Drop - Inches W.C. 2.03.92.8.86.90.93.96 2.00 2.02 2.05 (kpa) (0.5) (0.48) (0.45) (0.46) (0.47) (0.48) (0.49) (0.50) (0.50) (0.5) DIMENSIONAL DATA - Inches (mm) "A" Overall Unit Width 7-7/8 20-5/8 20-5/8 23-3/8 26-/8 28-7/8 3-5/8 37-/8 42-5/8 48-/8 (454) (524) (524) (594) (664) (733) (803) (943) (083) (222) "B" Discharge Opening 5-8-/4 8-/4 2 23-26- 29-/4 34-40-/4 45- (394) (464) (464) (533) (603) (673) (743) (883) (022) (62) "C" Hanging Distance Width 7-/8 9-7/8 9-7/8 22-5/8 25-3/8 28-/8 30-7/8 36-3/8 4-7/8 47-3/8 (435) (505) (505) (575) (645) (74) (784) (924) (064) (203) "D" Flue Opening Diameter* 4 4 4 4 5 5 5 6 6 6 (02) (02) (02) (02) (27) (27) (27) (52) (52) (52) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches Approximate Ship Weight - lb 6 80 88 207 227 246 266 305 344 383 (kg) (73) (82) (85) (93) (03) (6) (2) (38) (56) (74) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in U.S.A. above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (N.F.P.A. No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. QVSD Separated Combustion Duct Furnace Bottom Service Access Only DIMENSIONS XXX STANDARD UNITS DIMENSIONS IN PARENTHESIS (XXX) MILLIMETERS 8

QVED/QVES Series Power Vented Duct Furnace Performance and Dimensional Data UNIT CAPACITY (MBH) 00 25 50 75 200 225 250 300 350 400 PERFORMANCE DATA Input (Maximum) - BTU/Hr. 00,000 25,000 50,000 75,000 200,000 225,000 250,000 300,000 350,000 400,000 (kw) (29.3) (36.6) (44.0) (5.3) (58.6) (65.9) (73.3) (87.9) (02.6) (7.2) Input (Minimum) - BTU/Hr. 50,000 62,500 75,000 87,500 00,000 2,500 25,000 50,000 75,000 200,000 (kw) (4.6) (8.3) (22.0) (25.6) (29.3) (33.0) (36.6) (44.0) (5.3) (58.6) Output - BTU/Hr. 80,000 00,000 20,000 40,000 60,000 80,000 200,000 240,000 280,000 320,000 (kw) (23.4) (29.3) (35.) (4.0) (46.9) (52.7) (58.6) (70.3) (82.0) (93.7) Thermal Efficiency - % 80 80 80 80 80 80 80 80 80 80 Free Air Delivery (Minimum) - CFM 929,57,389,620,852 2,083 2,35 2,778 3,24 3,704 (cu. m/s) (0.438) (0.546) (0.656) (0.765) (0.874) (0.983) (.093) (.3) (.530) (.748) Air Temperature Rise - F 80 80 80 80 80 80 80 80 80 80 ( C) (44) (44) (44) (44) (44) (44) (44) (44) (44) (44) Pressure Drop - Inches W.C. 0.2 0.3 0.5 0.4 0.4 0.4 0.4 0.3 0.3 0.4 (kpa) (0.03) (0.03) (0.04) (0.03) (0.03) (0.03) (0.03) (0.03) (0.03) (0.03) Free Air Delivery (Maximum) - CFM 2,469 3,086 3,704 4,32 4,938 5,556 6,73 7,407 8,642 9,877 (cu. m/s) (.65) (.457) (.748) (2.040) (2.33) (2.622) (2.94) (3.496) (4.079) (4.662) Air Temperature Rise - F 30 30 30 30 30 30 30 30 30 30 ( C) (7) (7) (7) (7) (7) (7) (7) (7) (7) (7) Pressure Drop - Inches W.C. 0.90 0.80 0.75 0.75 0.75 0.75 0.80 0.90 0.90 0.90 (kpa) (0.22) (0.20) (0.9) (0.9) (0.9) (0.9) (0.20) (0.22) (0.22) (0.22) DIMENSIONAL DATA - Inches (mm) "A" Overall Unit Width 7-7/8 20-5/8 20-5/8 23-3/8 26-/8 28-7/8 3-5/8 37-/8 42-5/8 48-/8 (454) (524) (524) (594) (664) (733) (803) (943) (083) (222) "B" Discharge Opening 5-8-/4 8-/4 2 23-26- 29-/4 34-40-/4 45- (394) (464) (464) (533) (603) (673) (743) (883) (022) (62) "C" Hanging Distance Width 7-/8 9-7/8 9-7/8 22-5/8 25-3/8 28-/8 30-7/8 36-3/8 4-7/8 47-3/8 (435) (505) (505) (575) (645) (74) (784) (924) (064) (203) "D" Flue Opening Diameter* 4 4 4 4 5 5 5 6 6 6 (02) (02) (02) (02) (27) (27) (27) (52) (52) (52) "F" Clearance for Burner Drawer 23-7/8 25-5/8 26-5/8 29-3/8 32-/8 34-7/8 37-5/8 43-/8 48-5/8 54-/8 Access (Side Access Type Only) (606) (65) (676) (746) (86) (886) (956) (095) (235) (375) Gas Inlet, Natural Gas - Inches Gas Inlet, LP Gas - Inches Approximate Ship Weight - lb 73 86 97 26 232 254 263 32 389 403 (kg) (78) (84) (89) (98) (05) (5) (9) (42) (76) (83) Ratings shown are for unit installations at elevations between 0 and 2,000 ft (0 to 60m). For unit installations in U.S.A. above 2,000 ft. (60m), the unit input must be derated 4% for each,000 ft. (305m) above sea level; refer to local codes, or in absence of local codes, refer to the latest edition of the National Fuel Gas Code, ANSI Standard Z223. (N.F.P.A. No. 54). For installations in Canada, any reference to deration at altitudes in excess of 2,000 ft. (60m) are to be ignored. At altitudes of 2,000 ft. to 4,500 ft. (60 to 372m), the unit must be derated to 90% of the normal altitude rating, and be so marked in accordance with the ETL certification. * Flue collar is factory supplied with unit; to be field installed per included instructions. Temperature Rise and Pressure Drop Graph 9

QVED/QVED Series Power Vented Duct Furnace Dimensional Data QVED Power Vented Duct Furnace Bottom Service Acccess QVES Power Vented Duct Furnace Side Service Access Detail G 20

CAB Series Cabinet Blower STANDARD FEATURES Sterling Cabinet Blowers have been especially designed for use with Sterling Duct Furnaces. Duct Flange at rear to facilitate attaching Ductwork. Side panels removable for inspection, servicing and motor maintenance. Specify Unit Number of both Cabinet Blower and Duct Furnace on Order, thus CAB2 50 indicates CAB2 Blower with 50,000 BTU Duct Furnace. Four sizes provide CFM capacities ranging from,250 to 8,000 CFM (0.59 to 3.78 m 3 /s). Sheet metal duct pieces for connecting Cabinet Blower to Duct Furnace are furnished only with Sterling Cabinet Blower-Duct Furnace combinations. Cabinet finished in baked enamel. Unit Number Description Digit C X X X 2 3 4 5 6 7 8 9 0 + Item Prefix UT CA SV MT MS AS (Internal use Only), 2, 3, 4 - Unit Type [UT] CAB - Cabinet Blower Size CAB2 - Cabinet Blower Size 2 CAB3 - Cabinet Blower Size 3Propeller CAB4 - Cabinet Blower Size 4 5, 6, 7 - Furnace Capacity [CA]* 00-00,000 BTU/HRBTU/HR 25-25,000 BTU/HR 50-50,000 BTU/HR 75-75,000 BTU/HR 200-200,000 BTU/HR 225-225,000 BTU/HRBTU/HR 250-250,000 BTU/HRBTU/HR 300-300,000 BTU/HRBTU/HR 350-350,000 BTU/HRBTU/HR 400-400,000 BTU/HRBTU/HR 000 - No Transition Required * Indicates transition duct size needed for corresponding QVED or QVES Duct Furnace. Refer to Compatible Duct Furnace Capacity indicated in the table on page 22. 8 - Supply Voltage [SV] - 5//60 5-230/3/60 2-208//60 6-460/3/60 3-230//60 7-575/3/60 4-208/3/60 Z - Other 9 - Motor Type [MT] - Open Drip Proof 2 - Totally Enclosed 3 - Premium Efficiency, Open Drip Proof 4 - Premium Efficiency, Totally Enclosed - Accessories [AS] All Accessories are to be entered as a separate line item using the catalog number which utilizes AS as a prefix. i.e: F becomes AS-F. FACTORY INSTALLED B - in. Washable Filters B6 - in. Throwaway Filters K4 - Fan Time Delay P4 - Terminal Block Wiring Y5 - Cabinet Insulation Y6 - Transition Insulation FIELD INSTALLED (AS- ) F - -Stage T675A Ductstat F2-2-Stage T678A Ductstat G - -Stage T87K Mercury Free Thermostat w/subbase G2 - -Stage T87K Mercury Free Thermostat w/tg5a Guard Kit G3 - -Stage T834N Mercury Free Thermostat/Fan Switch G5-2-Stage TH5220D Mercury Free Thermostat w/subbase G6 - Locking Thermostat Cover G8 - -Stage T669C Line Voltage Stat w/subbase G9 - -Stage T822K Mercury Free Thermostat 0 - Blower Motor Sizes [MS] B - /3 HP. w /Contactor P - HP w/magnetic Starter C - HP. w/contactor R - HP w/magnetic Starter D - HP. w/contactor S - HP w/magnetic Starter F - HP. w/contactor T - - HP w/magnetic Starter G - - HP. w/contactor U - 2 HP w/magnetic Starter H - 2 HP. w/contactor W - 3 HP w/magnetic Starter J - 3 HP. w/contactor Y - /3 HP w/magnetic Starter K - /3 HP. L - HP. M - HP. N - HP. Motor Data CURRENT /3 H.P. H.P. H.P. H.P. - H.P. 2 H.P. 3 H.P. CHARACTERISTICS R.P.M. AMPS R.P.M. AMPS R.P.M. AMPS R.P.M. AMPS R.P.M. AMPS R.P.M. AMPS R.P.M. AMPS 5--60 725 5.9 725 7.2 5.4 6.4 26 5/230--60 725 5.5 725 7.7 725 8.2 725 3 Approx. Ship Wt. 6# 2# 25# 3# 4# 44# 28 2.6 3.2 4.3 5.8 9.5 208/230/460-3-60 725.4 725.3 725.6 725 2.2 725 2.9 725 4.8 Approx. Ship Wt. MOTOR FRAME MUST NOT EXCEED NEMA SIZE 56. 25# 28# 3# 4# 4# 43# 2

CAB Series Cabinet Blower Dimensional Data A B C D E F G APPR. SHIP WT. MODEL in. in. in. in. in. in. in. FILTER DATA FILTER LESS MOTOR NO. * (mm) (mm) (mm) (mm) (mm) (mm) (mm) SIZE ** REQ D. LB (KG) CAB-/00 65-26 0 8 2-/4 5-5-5/8 25 X 25 X 35 (664) (660) (254) (457) (540) (400) (397) (6) CAB-/25 65-26 0 8 2-/4 5-8-3/8 25 X 25 X 35 (664) (660) (254) (457) (540) (400) (467) (6) CAB-2/50 65-26 0 8 2-/4 5-8-3/8 25 X 25 X 55 (664) (660) (254) (457) (540) (400) (467) (70) CAB-2/75 65-26 0 8 2-/4 5-2-/8 25 X 25 X 55 (664) (660) (254) (457) (540) (400) (537) (70) CAB-3/200 65-40- 0 8 35-30-3/8 23-7/8 25 X 20 X 2 200 (664) (029) (254) (457) (908) (772) (606) (9) CAB-3/225 65-40- 0 8 35-30-3/8 26-5/8 25 X 20 X 2 200 (664) (029) (254) (457) (908) (772) (676) (9) CAB-3/250 65-40- 0 8 35-30-3/8 29-3/8 25 X 20 X 2 200 (664) (029) (254) (457) (908) (772) (746) (9) CAB-4/300 65-60- 0 8 55-50-3/8 34-7/8 25 X 20 X 3 296 (664) (537) (254) (457) (46) (280) (886) (34) CAB-4/350 69-60- 4 22 55-50-3/8 40-3/8 25 X 20 X 3 296 (765) (537) (356) (559) (46) (280) (026) (34) CAB-4/400 69-60- 4 22 55-50-3/8 45-7/8 25 X 20 X 3 296 (765) (537) (356) (559) (46) (280) (65) (34) *Never use a single cabinet blower to handle more than one duct furnace. CAB-4 has two blowers driven by one motor. **Standard filters are '' thick throw away type. Side panels removable for inspection, servicing and motor maintenance. Cabinet painted gray enamel. Sterling reserves the right to change specifications without incurring obligations. Cabinet blower units are not certified by ETL. 22

CAB Series Cabinet Blower Performance Data Total Static Pressure * in. of W.C. 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 DUCT FURNACE SECTIONS (kpa) (0.05) (0.07) (0.0) (0.2) (0.5) (0.7) (0.20) (0.22) PRESSURE DROP MODEL CFM RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP RPM HP SIZE in. W.C. SIZE in. W.C. (cu. m/s) (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kw) (kpa) (kpa),250 525 /3 650 /3 680 /3 760 /3 780 /3 840 /3........ 00 0.6.... (0.590) (0.25) (0.25) (0.25) (0.25) (0.25) (0.25) (0.04),250 525 /3 650 /3 680 /3 760 /3 780 /3 840 /3........ 25 0.0.... CAB (0.590) (0.25) (0.25) (0.25) (0.25) (0.25) (0.25) (0.02) 0",500 600 /3 680 /3 75 /3 790 /3 80 860 895 970 25 0.5.... BLOWER (0.708) (0.25) (0.25) (0.25) (0.25) (0.37) (0.37) (0.37) (0.37) (0.04),750 650 /3 70 /3 750 805 850 890 940 990 25 0.8.... (0.826) (0.25) (0.25) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.04) 2,000 700 760 800 850 890 925 980,00 25 0.24.... (0.944) (0.37) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.56) (0.06),500 425 /3 500 /3 550 /3 630 /3................ 50 0.09 75 0.07 (0.708) (0.25) (0.25) (0.25) (0.25) (0.02) (0.02),750 450 /3 55 /3 560 /3 635 680 725........ 50 0.5 75 0. (0.826) (0.25) (0.25) (0.25) (0.37) (0.37) (0.37) (0.04) (0.03) CAB 2 2,000 475 /3 530 /3 590 640 690 740 785 80 50 0.20 75 0.4 2" (0.944) (0.25) (0.25) (0.37) (0.37) (0.37) (0.37) (0.37) (0.56) (0.05) (0.03) BLOWER 2,250 55 560 60 650 700 750 790 85 75 0.8.... (.062) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.04) 2,500 540 590 625 670 70 760 795 820 75 0.22.... (.80) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.05) 2,750 575 65 650 690 730 780 800 830 75 0.27.... (.298) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.56) (0.75) (0.07),750 450 /3 50 /3 560 /3 630 /3 675 720........ 200 0.09.... (0.826) (0.25) (0.25) (0.25) (0.25) (0.37) (0.37) (0.02) 2,000 475 /3 525 /3 590 635 680 735 785 80 200 0. 225 0.09 (0.944) (0.25) (0.25) (0.37) (0.37) (0.37) (0.37) (0.37) (0.56) (0.03) (0.02) 2,250 500 550 600 645 685 740 785 80 200 0.4 225 0. (.062) (0.37) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.56) (0.03) (0.03) 2,500 525 580 65 665 700 750 790 85 200 0.7 225 0.3 (.80) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.04) (0.03) 2,750 560 605 640 685 75 775 805 825 200 0.20 225 0.4 CAB 3 (.298) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.56) (0.75) (0.05) (0.03) 2" 3,000 60 640 660 70 750 790 85 845 200 0.22 225 0.75 BLOWER (.46) (0.37) (0.56) (0.56) (0.56) (0.75) (0.75) (0.75) (0.75) (0.05) (0.04) 2,250 500 550 590 645 675 735 780 805 250 0.09.... (.062) (0.37) (0.37) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.02) 2,500 520 580 60 665 700 745 800 80 250 0..... (.80) (0.37) (0.37) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.03) 2,750 550 605 640 680 70 770 80 820 250 0.2.... (.298) (0.37) (0.37) (0.56) (0.56) (0.56) (0.56) (0.56) (0.56) (0.03) 3,000 600 640 670 705 730 785 820 840 250 0.4.... (.46) (0.56) (0.56) (0.56) (0.56) (0.56) (0.75) (0.75) (0.75) (0.03) 3,250 630 675 700 735 750 790 830 860 250 0.6.... (.534) (0.56) (0.56) (0.75) (0.75) (0.75) (0.75) (0.75) (0.75) (0.04) 3,500 675 700 725 775 800 840-875 - 890-250 0.20.... (.652) (0.56) (0.75) (0.75) (0.75) (0.75) (.2) (.2) (.2) (0.05) 2,750 400 450 50.................... 300 0.09.... (.298) (0.56) (0.56) (0.56) (0.02) 3,000 425 475 550 600 650............ 300 0.0.... (.46) (0.56) (0.56) (0.56) (0.56) (0.56) (0.02) 3,500 430 480 560 60 660 700 730.... 300 0.4 350 0. (.652) (0.56) (0.56) (0.56) (0.56) (0.56) (0.75) (0.75) (0.03) (0.02) 4,000 450 500 565 65 670 70 740 790 300 0.8 350 0.3 (.888) (0.56) (0.56) (0.56) (0.56) (0.75) (0.75) (0.75) (0.75) (0.04) (0.03) 4,500 475 525 575 620 680 75 750 800-350 0.6 400 0.4 (2.24) (0.56) (0.56) (0.56) (0.75) (0.75) (0.75) (0.75) (.2) (0.04) (0.03) 5,000 500 540 600 630 690 720-760 - 80-350 0.20 400 0.7 (2.360) (0.56) (0.56) (0.75) (0.75) (0.75) (.2) (.2) (.2) (0.05) (0.04) 5,500 530 575 65 650-700 - 700-730 - 820-350 0.23 400 0.2 CAB 4 (2.596) (0.75) (0.75) (0.75) (.2) (.2) (.2) (.2) (.2) (0.06) (0.05) (2) 2" 6,000 575-65 - 660-690 - 75-760 2 800 2 830 2 350 0.26 400 0.23 BLOWERS (2.832) (.2) (.2) (.2) (.2) (.2) (.49) (.49) (.49) (0.06) (0.06) 6,500 60-660 2 70 2 750 2 800 2 840 2 890 3 930 3 350 0.30 400 0.26 (3.068) (.2) (.49) (.49) (.49) (.49) (.49) (2.24) (2.24) (0.07) (0.06) 7,000 720-790 2 830 2 860 2 90 3 940 3 960 3 NA 400 0.28.... (3.304) (.2) (.49) (.49) (.49) (2.24) (2.24) (2.24) (0.07) 7,500 800 2 860 2 900 3 930 3 960 3 NA NA NA 400 0.30.... (3.540) (.49) (.49) (2.24) (2.24) (2.24) (0.07) 8,000 860 2 930 3 960 3 NA NA NA NA NA 400 0.3.... (3.776) (.49) (2.24) (2.24) (0.08) *External static pressure in inches of W.C. Add the pressure drop of the duct furnace and the pressure drop of the ductwork to determine the total external static pressure. 23

Accessories [AC] FACTORY INSTALLED A8 - INPUT DERATE Series QVED, QVES, QVSD Factory Installed Unit is derated up to 50% for specific applications. K4 - FAN TIME DELAY Series QVED, QVES, QVSD Thermal bi metalic type time delay is standard on all units except duct furnaces. Provides a 60 delay on and 45 second delay off for blower operation. K5 - AIR FLOW PROVE SWITCH Series QVED, QVES and QVSD Factory Installed A Dwyer 90-0 pressure switch with an operating range of 0.5-0.5" WC. M6 - OSHA TYPE FAN GUARD Series TF, SF Factory installed available on series TF and SF only, standard on series GG. Required for installations that must conform to OSHA standards. Also known as fingerproof fan guards. M8 - DISCHARGE DUCT FLANGE ASSEMBLY Series TC, SC Factory Installed (Specify No Charge) Used in lieu of louvers on blower units for incorporating field duct work. P4 - TERMINAL BLOCK WIRING Series TF, TC, SF, SC, QVED, QVES, QVSD Factory Installed Provides specific terminal designation for field wiring. P6 - SUMMER/WINTER SWITCH Series TF, TC, SF, SC, QVED, QVES, QVSD Factory Installed Allows operation of fan or blower for ventilating purposes during hot summer months (manually operated). S - 409 STAINLESS STEEL BURNERS Series QVED, QVES, QVSD Factory Installed 409 stainless steel burners in lieu of the standard aluminized steel burners. S3 - STAINLESS STEEL FLUE COLLECTOR All Series and Sizes Factory Installed 409 Stainless steel flue collector in lieu of standard aluminized steel collector. S5 - STAINLESS STEEL BURNERS Series TF, TC, SF, SC Factory Installed 304L Stainless steel in-shot burners in lieu of the standard aluminized steel in-shot burners. FIELD INSTALLED A7 - PRESSURE REGULATOR -2 PSI All Series & Sizes Required where main line pressure exceeds 4" WC ( psig), must specify incoming pressure when ordered. One regulator per unit required, shipped separately. F - ONE STAGE DUCTSTAT Series TC, SC, QVED, QVES, QVSD Single pole, double throw. 55-75 F setpoint range. [2" W x 5-5/8" H x 2-7/6" D] F2 - TWO STAGE DUCTSTAT Series TC, SC, QVED, QVES, QVSD Single pole, double throw. 55-75 F setpoint range. [2" W x 5-5/8" H x 2-7/6" D] G - ONE STAGE T87K (MERCURY-FREE) THERMOSTAT WITH SUBBASE All Series and Sizes Single stage heating thermostat with subbase. Includes fan switching relay. Standard round styling suitable for any decor. 40-90 F range. G2 - ONE STAGE T87K (MERCURY-FREE) THERMOSTAT WITH TG5A GUARD All Series and Sizes Same features as G except a tamper proof guard is included. G3 - ONE STAGE T834N (MERCURY-FREE) THERMOSTAT WITH FAN SWITCH All Series and Sizes Single stage heating thermostat with fan switch. Manufactured exclusively for Sterling with a Sterling logo face plate. 50-90 F range. [2-3/8" W x 4-" H x -" D] G5 - TWO STAGE TH5220D (MERCURY-FREE) THERMOSTAT WITH SUBBASE All Series and Sizes Two stage heating and two stage cooling with system and fan switching and built in 0 F heating/cooling differential. Includes fan relay. Heating 40-90 F range, Cooling 50-99 F. [5-3/6" W x 3-9/6" H x -" D] G6 - LOCKING THERMOSTAT COVER All Series and Sizes Universal locking thermostat cover for use with all thermostats listed. G8 - ONE STAGE T669C LINE VOLTAGE STAT WITH SUBBASE All Series and Sizes Single stage heating only thermostat. 5 volt operation. 44-86 F range [4-" W x 4-5/8" H x -7/8" D] G9 - ONE STAGE T822K (MERCURY-FREE) THERMOSTAT All Series and Sizes Single stage heating only thermostat with subbase. 24 volt operation. 50-90 F range. [2-7/8" W x 4-" H x -" D] H5 - LOW AMBIENT CONTROL Series QVED, QVES and QVSD Disengages duct furnace(s) from firing in times of mild ambient temperatures. M2 -, 2, 3 - VENT CAP Series TF, TC, SF, SC, QVED, QVES, QVSD 4 (QVED, QVES, QVSD only), 5 or 6 inch vent cap for use with series TF, TC, SF, SC, QVED, QVES, QVSD. Must indicate unit size when ordered. M3- - ADAPTOR Series QVED, QVES and QVSD 4 to 5" flue vent adaptor for use with 00 through 75 MBH power vented units. Power vented unit capacities 300, 350 and 400 require 5 to 6" flue vent adaptor which is supplied with the unit as standard equipment. M4 - VERTICAL CONCENTRIC FLUE KIT Series QVSD Allows for one 8 inch vent/combustion air vertical penetration through a structure. Kit includes collection box, 5" flue gas vent cap and 8" combustion air inlet cap. M5- HORIZONTAL CONCENTRIC FLUE KIT Series QVSD Allows for one 8 inch vent/combustion air horizontal penetration through a structure. Kit includes collection box, 5" flue gas vent cap and 8" combustion air inlet cap. M7-2 to 4 POINT SUSPENSION KIT Series TF, SF Kit converts 2 point unit heater suspension to 4 point. P2 - ADJUSTABLE HIGH LIMIT SWITCH Series QVED, QVES and QVSD Adjustable switch used in conjunction with the standard header mounted high limit switch. 24

Accessories [AC] P3 - ADJUSTABLE FAN SWITCH Series QVED, QVES, QVES and QVSD Adjustable switch used to cycle a separate blower. P5-24 VOLT RELAY All Series and Sizes Specify purpose. 24 volt SPST relay. Q7 - HORIZONTAL AND VERTICAL LOUVERS Series QVED, QVES and QVSD For four way deflection on duct. S4-409 STAINLESS STEEL DRAIN PAN Series QVED, QVES Condensate drain pan typically used when cooling coils are installed upstream of duct. VC - 4 VENT CAP Series GG 4" vent cap for use with series GG. X2-30 NOZZLE Series GG, TF, TC, SF, SC Directs the discharge air at a 30 angle. Air can be directed up to 60 by adjusting the horizontal louvers. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X3-60 NOZZLE Series GG, TF, TC, SF, SC Directs the discharge air at a 60 angle. Air can be directed up to 90 by adjusting the horizontal louvers. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X4-90 NOZZLE Series GG, TF, TC, SF, SC Directs the discharge air at a 90 angle. Louvers are supplied with the unit heater and must be reinstalled in the nozzle discharge. Must indicate unit size when ordered. X5 - VERTICAL LOUVER KIT Series TF, TC, SF, SC Vertical Louvers to provide 4 way air deflection. Must indicate unit size when ordered. X7-4, 5 COMBUSTION AIR INLET KIT Series GG Allows for one 6 or 8" vent/combustion air opening through a structure. One kit permits for either horizontal or vertical applications. Kit required for converting a series GG to separated combustion. X7 - H5, H6 HORIZONTAL COMBUSTION AIR INLET KIT Series SF, SC Allows for one 8 or 0" horizontal vent/ combustion air opening through a structure. Must indicate unit size when ordered. X7 - V5, V6 VERTICAL COMBUSTION AIR INLET KIT Series SF, SC Allows for one 8 or 0" vertical vent/ combustion air opening through a structure. Must indicate unit size when ordered. 25

Heat Throw Data NOTES:. All throw data shown below is for tubular unit heaters only excludes Series QVED, QVES, QVSD and CAB. 2. All throw data figures are approximations. Allowances should be made for optimum performance, altitude, etc. 3. NR - Units not recommended at these mounting heights. 4. 30, 60 and 90 nozzles are shipped unassembled. STANDARD UNIT HEATER APPLICATIONS 30 NOZZLE Distance From Floor to Bottom of Unit H Approximate Distance of Heat Throw - Feet (Meters) UNIT SIZE BTU/HR (kw) Ft. 30,000 45,000 60,000 75,000 (m) (8.8) (3.2) (7.6) (22.0) 8 33 33 33 40 (2.4) (0.) (0.) (0.) (2.2) 0 28 28 28 35 (3.0) (8.5) (8.5) (8.5) (0.7) 2 (3.7) NR NR NR NR 5 (4.6) NR NR NR NR 20 (6.) NR NR NR NR UNIT SIZE BTU/HR (kw) 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 40 60 60 65 (2.4) (2.2) (8.3) (8.3) (9.8) 0 35 54 54 56 (3.0) (0.7) (6.5) (6.5) (7.) 2 44 44 46 NR (3.7) (3.4) (3.4) (4.0) 5 (4.6) NR NR NR NR 20 (6.) NR NR NR NR UNIT SIZE BTU/HR (kw) 25,000 50,000 75,000 200,000 (36.6) (43.9) (5.2) (58.6) 8 65 70 75 80 (2.4) (9.8) (2.3) (22.9) (24.4) 0 56 60 64 68 (3.0) (7.) (8.3) (9.5) (20.7) 2 46 49 57 6 (3.7) (4.0) (4.9) (7.4) (8.6) 5 45 49 52 NR (4.6) (3.7) (4.9) (5.8) 20 46 NR NR NR (6.) (4.0) UNIT SIZE BTU/HR (kw) 250,000 300,000 350,000 400,000 (73.2) (87.8) (02.5) (7.) 8 90 05 0 20 (2.4) (27.4) (32.0) (33.5) (36.6) 0 78 90 95 00 (3.0) (23.8) (27.4) (29.0) (30.5) 2 68 80 84 90 (3.7) (20.7) (24.4) (25.6) (27.4) 5 60 70 74 80 (4.6) (8.3) (2.3) (22.6) (24.4) 20 54 63 66 70 (6.) (6.5) (9.2) (20.) (2.3) Distance From Floor to Bottom of Unit H Ft. (m) 8 (2.4) 0 (3.0) 2 (3.7) 5 (4.6) 20 (6.) Approximate Distance of Heat Throw - Feet (Meters) UNIT SIZE BTU/HR (kw) 30,000 45,000 60,000 75,000 (8.8) (3.2) (7.6) (22.0) Data Not Available Data Not Available Data Not Available Data Not Available Data Not Available UNIT SIZE BTU/HR (kw) 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 Data Not 65 Data Not Data Not (2.4) Available (9.8) Available Available 0 Data Not 57 Data Not Data Not (3.0) Available (7.4) Available Available 2 Data Not 50 Data Not Data Not (3.7) Available (5.2) Available Available 5 Data Not Data Not Data Not NR (4.6) Available Available Available 20 Data Not Data Not Data Not NR (6.) Available Available Available UNIT SIZE BTU/HR (kw) 25,000 50,000 75,000 200,000 (36.6) (43.9) (5.2) (58.6) 8 70 75 80 85 (2.4) (2.3) (22.9) (24.4) (25.9) 0 60 64 68 72 (3.0) (8.3) (9.5) (20.7) (2.9) 2 54 57 60 64 (3.7) (6.5) (7.4) (8.3) (9.5) 5 45 48 50 53 (4.6) (3.7) (4.6) (5.2) (6.2) 20 44 47 NR NR (6.) (3.4) (4.3) UNIT SIZE BTU/HR (kw) 250,000 300,000 350,000 400,000 (73.2) (87.8) (02.5) (7.) 8 95 5 20 25 (2.4) (29.0) (35.) (36.6) (38.) 0 86 99 05 0 (3.0) (26.2) (30.2) (32.0) (33.5) 2 77 88 94 00 (3.7) (23.5) (26.8) (28.7) (30.5) 5 64 74 79 84 (4.6) (9.5) (22.6) (24.) (25.6) 20 58 66 7 75 (6.) (7.7) (20.) (2.6) (22.9) 26

Heat Throw Data Distance From Floor to Bottom of Unit H Ft. (m) 8 (2.4) 0 (3.0) 2 (3.7) 5 (4.6) 20 (6.) 60 NOZZLE Approximate Distance of Heat Throw (Feet) Approximate Distance of Heat Throw - Feet (Meters) UNIT SIZE BTU/HR (kw) 30,000 45,000 60,000 75,000 (8.8) (3.2) (7.6) (22.0) Data Not Available Data Not Available Data Not Available Data Not Available Data Not Available UNIT SIZE BTU/HR (kw) 90,000 00,000 05,000 20,000 (26.4) (29.3) (30.8) (34.2) 8 Data Not 75 Data Not Data Not (2.4) Available (22.9) Available Available 0 Data Not 65 Data Not Data Not (3.0) Available (9.8) Available Available 2 Data Not 60 Data Not Data Not (3.7) Available (8.3) Available Available 5 Data Not 50 Data Not Data Not (4.6) Available (5.2) Available Available 20 Data Not Data Not Data Not NR (6.) Available Available Available UNIT SIZE BTU/HR (kw) 25,000 50,000 75,000 200,000 (36.6) (43.9) (5.2) (58.6) 8 80 85 90 95 (2.4) (24.4) (25.9) (27.4) (29.0) 0 70 75 79 83 (3.0) (2.3) (22.9) (24.) (25.3) 2 64 68 72 76 (3.7) (9.5) (20.7) (2.9) (23.2) 5 54 56 6 65 (4.6) (6.5) (7.) (8.6) (9.8) 20 49 52 55 59 (6.) (4.9) (5.8) (6.8) (8.0) UNIT SIZE BTU/HR (kw) 250,000 300,000 350,000 400,000 (73.2) (87.8) (02.5) (7.) 8 0 25 30 38 (2.4) (33.5) (38.) (39.6) (42.) 0 95 09 5 20 (3.0) (29.0) (33.2) (35.) (36.6) 2 84 00 03 08 (3.7) (25.6) (30.5) (3.4) (32.9) 5 7 85 88 94 (4.6) (2.6) (25.9) (26.8) (28.7) 20 65 77 8 85 (6.) (9.8) (23.5) (24.7) (25.9) Distance From Floor to Bottom of Unit H Ft. (m) 0 90 NOZZLE* Approximate Distance of Heat Throw - Feet (Meters) UNIT SIZE BTU/HR (kw) 00,000 25,000 50,000 (29.3) (36.6) (43.9) NR NR NR (3.0) 5 30 25 35 30 40 35 (4.6) (9.) x (7.6) (0.7) x (9.) (2.2) x (0.7) 20 (6.) NR NR NR 25 (7.6) NR NR NR 30 (9.) NR NR NR UNIT SIZE BTU/HR (kw) 75,000 200,000 250,000 (5.2) (58.6) (73.2) 0 (3.0) NR NR NR 5 45 40 50 40 60 45 (4.6) (3.7) x (2.2) (5.2) x (2.2) (8.3) x (3.7) 20 40 35 56 40 NR (6.) (2.2) x (0.7) (7.) x (2.2) 25 50 35 NR NR (7.6) (5.2) x (0.7) 30 (9.) NR NR NR UNIT SIZE BTU/HR (kw) 300,000 350,000 400,000 (87.8) (02.5) (7.) 0 NR NR NR (3.0) 5 70 45 80 50 00 50 (4.6) (2.3) x (3.7) (24.4) x (5.2) (30.5) x (5.2) 20 65 40 70 45 80 45 (6.) (9.8) x (2.2) (2.3) x (3.7) (24.4) x (3.7) 25 60 35 65 40 75 40 (7.6) (8.3) x (0.7) (9.8) x (2.2) (22.9) x (2.2) 30 55 35 60 35 65 40 (9.) (6.8) x (0.7) (8.3) x (0.7) (9.8) x (2.2) *It is not recommended to mount a unit with a 90 nozzle at 0 feet or less. Heat Throw data for GG Series units with a 90 nozzle installed is not currently available. 27

Nozzle Dimensions* A C A C B D B 30 NOZZLE 60 NOZZLE A C D B 28 90 NOZZLE *Nozzles are field assembled. NOZZLE DIMENSIONAL DATA CHART DIMENSION NOZZLE TYPE 30, 45 60, 75 90, 05, 20 00, 25, 50 75, 200, 250 300, 350, 400 9-5/8 9-5/8 9-5/8 20-32- 50-30 WIDTH (498) (498) (498) (527) (832) (289) A 9-5/8 9-5/8 9-5/8 20-32- 50-60 In. (498) (498) (498) (527) (832) (289) (mm) 9-5/8 9-5/8 9-5/8 20-32- 50-90 (498) (498) (498) (527) (832) (289) 2-/6 5-5/8 22-3/8 3-3- 3-30 HEIGHT (306) (397) (568) (800) (800) (800) B 2-/6 5-5/8 22-3/8 3-3- 3-60 In. (306) (397) (568) (800) (800) (800) (mm) 2-/6 5-5/8 22-3/8 3-3- 3-90 (306) (397) (568) (800) (800) (800) 3-/8 3-/8 3-/8 5 5 5 FURTHEST 30 (333) (333) (333) (38) (38) (38) DEPTH 22-3/6 22-3/6 22-3/6 25-25- 25- C 60 (564) (564) (564) (648) (648) (648) In. (mm) 25-9/6 25-9/6 25-9/6 28-/4 28-/4 28-/4 90 (694) (694) (694) (78) (78) (78) HEIGHT WITH OVERHANG D In. (mm) 30 N/A 60 90 3-5/6 6-7/8 23-5/8 30 30 30 (338) (429) (600) (762) (762) (762) 5-/4 8-3/6 25-9/6 34 34 34 (387) (478) (649) (864) (864) (864)