INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT

Similar documents
INSTALLATION INSTRUCTIONS FOR 6797A737 HEAT PUMP FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR 8330*633* COOL ONLY A/C 8330*635* HEAT READY A/C 8530*63** HEAT PUMP CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 7370A736 FLUSH MOUNT CEILING PLENUM

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 8330*63**, 8530*63** CHILLGRILLE FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 8330*5511 MOUNTING KIT

INSTALLATION INSTRUCTIONS FOR 7330C740 FLUSH MOUNT CEILING ASSEMBLY

INSTALLATION INSTRUCTIONS FOR 9330F4552 FREE DELIVERY PLENUM KITS

INSTALLATION INSTRUCTIONS FOR MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY) CONTROL BOX KIT (12 VDC HEAT/COOL)

INSTALLATION INSTRUCTIONS FOR 7330*5511 OR 7330*5512 MOUNTING KIT 7330B751 CONTROL BOX KIT (12 VDC COOL ONLY)

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

INSTALLATION INSTRUCTIONS FOR SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMP

INSTALLATION INSTRUCTIONS FOR 6636 SERIES PACKAGE AIR CONDITIONER

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

INSTALLATION INSTRUCTIONS FOR 6536 SERIES TWO TON PACKAGED HEAT PUMP

SERVICE MANUAL FOR 6636A & 6636B SERIES TWO TON HIGH EFFICIENCY PACKAGED AIR CONDITIONERS

OPERATION AND MAINTENANCE INSTRUCTIONS FOR 6535 AND 6536 SERIES TWO TON PACKAGED HEAT PUMP

SERVICE MANUAL FOR ROOF TOP AIR CONDITIONERS

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz SERIES RV ROOF TOP AIR CONDITIONER/HEAT PUMP

Install Guide Customer Support: or Visit our website

SERVICE MANUAL FOR 6795B,C,D SERIES PACKAGED AIR CONDITIONERS

SERVICE MANUAL FOR 6633 SERIES PACKAGE AIR CONDITIONER

INSTALLATION INSTRUCTIONS FOR. 230/240 VAC, 1ø, 50Hz 473X3 SERIES RV ROOF TOP AIR CONDITIONER

Install Guide 8046 ENGLISH. Customer Support: or: visit our website Printed in China ON.

Install Guide Customer Support: or Visit our website

OPERATION AND MAINTENANCE INSTRUCTIONS FOR SERIES TWO TON PACKAGED HEAT PUMP

OPERATION AND MAINTENANCE INSTRUCTIONS FOR ROOF TOP HEAT PUMPS AND CEILING PLENUMS

Operator: Save these instructions for future use!

Installation Instructions

BR342 Ducted Installation Instructions Australian Version Electronic Wall Control

Single Zone LCD Thermostat Operating Instructions

Install Guide 3M-10 ENGLISH

Operator: Save these instructions for future use!

OPERATING INSTRUCTIONS

Digital Non-Programmable

ITC 2000 HEATING CONTROL CABINET. Installation & Operation Manual

Thermostats. Digital Non-Programmable. GEAppliances.com. Owner s Manual & Installation Instructions RAK148D2 RAK164D2

Operator: Save these instructions for future use!

Operator: Save these instructions for future use!

Air Conditioner

CONTENTS A FEW WORDS ABOUT YOUR NEW AIR CONDITIONING UNIT 2 ELECTRICAL DATA 2 OPERATING INSTRUCTIONS 4

Thermostats. Digital Programmable. GEAppliances.com

T-32-TS Touchscreen Thermostat. Installation Manual

1F Non-programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Install guide Customer Support: or Visit our website OFF FAN HEAT COOL AUTO ON

Operator: SaVe these instructions forfuture use

BRISK AIR 579 Series 590 Series 595 Series

Ç Consilium Consilium US, Inc. 59 Porter Rd Littleton, MA USA

CommStat 4 Controller

Schneider Electric Erie T155 Series

Operator: Save these instructions for future use!

OPERATION AND MAINTENANCE INSTRUCTIONS FOR SERIES ROOF TOP HEAT PUMPS AND CEILING PLENUMS

Safety & Installation Instructions

09/23/2013. RECORD THIS UNIT INFORMATION FOR FUTURE REFERENCE: Model Number: Serial Number: Date Purchased:

Operator: Save these instructions for future use!

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

AirV Standard-Profile RV Air Conditioning

FAST-STAT Black. Red. Gray. Purple. Orange. Orange. Black. Black. Compressor Stage 1 Heat Control. Transformer Transformer L1 L2

12.0 cu.ft., 2 way, 4-door, R.V. refrigerator with ice maker.

Install guide 8010 ENGLISH. Customer Support: or Visit our webiste Made in China

INSTALLATION & OPERATING INSTRUCTIONS. Roof Top Unit. Model. USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

LZP-2 ZONE CONTROL PANEL

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

CT2700 An Electronic Round Programmable Thermostat

Installation Requirements for Models:

Norcold Repair Guide for Ice Maker

SC Installation, Operation & Application Guide

Safety & Installation Instructions

Install guide 8035C ENGLISH Printed in China MENU PROG RESET MENU PROG RESET

Comfort System T-21-P Touchscreen Thermostat Installation Manual

MODELS , , Series

INSTALLATION MANUAL. This manual covers TopTech models: TT-S-755H. Need Help? Thermostat Applications Guide. Power Type. Table of Contents.

SERIES VAC Microprocessor-Based Hot Surface Ignition Control FEATURES APPLICATIONS SPECIFICATIONS DESCRIPTION AGENCY CERTIFICATIONS

2 THERMOSTAT DETAILS 3 REMOVING OLD THERMOSTAT

INSTALLATION MANUAL. Need Help? This manual covers the following models: T755. Power Type. Thermostat Applications Guide. Page.

Smart Temp. ApolloP/n Installation Manual. Version 1.0

CWA4 Chilled & Hot Water Fan Coil

Operator: Save these instructions for future use

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES HEAT PUMP INSTRUCTIONS D INSTALLATION DE LA POMPE À CHALEUR SÉRIE 47000

CWA2 Chilled Water Fan Coil With or Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000-60,000 BTUH

Suburban RV FURNACES SERVICE MANUAL

Indoor Air Handlers with Compressors MVS and MVW

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

Install Guide CT100. Caution. Caution

G34M Bulletin #69/ August 2003

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

Model 17A00 Expansion Enclosure

SERIES & NO. SMI SUBJECT: SAFE CONSIDERATIONS FOR AN APPLICATION OF SPECIAL ELECTRICAL SYSTEMS

PROGRAMMABLE THERMOSTAT

B SERIES ELECTRIC FURNACE

IF79 CAUTION CONTENTS YOUR THERMOSTAT REPLACES 1 PREPARATIONS. Installation Instructions for. Heating & Air Conditioning

ELECTRONIC COMMUNICATING THERMOSTAT

Construction Electrical

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Transcription:

INSTALLATION INSTRUCTIONS FOR MODEL 7330D3351 & 7330D3361 WALL THERMOSTAT APPLICATION These thermostats are designed to operate all R.V. Products ceiling assemblies, which control the air conditioner 115 VAC circuits through 12 VDC relays. Wiring is required between the thermostat and the ceiling assembly. The thermostat wiring is field installed and must be considered before wall paneling and ceiling panels are in place. Wall thermostat controlled air conditioners are normally OEM (Original Equipment Manufacturer) installed. Wall thermostat controlled air conditioners may be installed for aftermarket applications, with additional considerations given to the thermostat wire routing. The 7330D3351 thermostat may also operate any RV furnace 12 VDC control circuit not exceeding one amp. All thermostats are equipped with a replaceable 2 amp fuse located on the back of the thermostat body. INSTALLATION INSTRUCTIONS BE SURE ALL ELECTRICAL POWER HAS BEEN DISCONNECTED FROM THE AIR CONDITIONER, THE CEILING ASSEMBLY AND THE POWER SUPPLY. These instructions are provided for the proper mounting of the thermostat itself. An Operation Chart and Terminal Cross Reference Chart are provided to show thermostat capabilities. Wiring procedure is dependent upon the ceiling assembly to be matched with this component, and is provided in the ceiling assembly installation instructions. Recreation Vehicle Products suggests the thermostat wiring be minimum 18 gauge. A. THERMOSTAT LOCATION This thermostat is a sensitive instrument. For accurate temperature control and comfort, the following considerations should be taken into account: 1. Locate the thermostat on an inside wall about five feet above the floor. Pick a dry area where air circulation is good. The thermostat should be mounted within a reasonable distance from the appliance the thermostat will control. This will assure a more accurate temperature relationship between the thermostat and the appliance the thermostat will control. 2. Do not install the thermostat where there are unusual heating conditions; such as direct sunlight, heat producing appliances (television, radio, wall lamp, etc.) or a furnace or air conditioner supply register. B. ROUTING THE THERMOSTAT WIRE BUNDLE A separate wire bundle to power the 12 VDC thermostat will need to be routed between the thermostat and the power supply. Both positive and negative must be brought up to the thermostat. If a 12 VDC furnace is also to be operated, additional wiring will need to be routed and a definite furnace location defined. See Figure 1. 1. Route the wire bundle between the thermostat and the ceiling assembly. Allow an additional 6 inches of length at both the thermostat and the ceiling assembly. This will give the installer the required slack necessary for wiring. See Figure 1. 2. Route the separate 2 wire thermostat bundle between the thermostat and the power supply. Allow 6 inches of additional wiring on both ends. See Figure 1. 3. If a 12 VDC furnace is to be operated, route a wire bundle between the thermostat and the furnace. Allow an additional 6 inches at both ends. See Figure 1. 4. If stapling the wire bundle during the routing process, be careful not to pierce the thermostat wiring insulation. C. ATTACHING THE WALL THERMOSTAT 1. Separate the thermostat body from the sub-base by gently pulling at the top and bottom. See Figure 2. 2. If this thermostat is a replacement thermostat for one which has failed or no longer meets the needs of the system: note the thermostat wiring on the back of the old thermostat sub-base, and the system function each wire was operating. This will save time and trouble when rewiring the new thermostat. Before removing the thermostat wiring from the old thermostat, make sure the power supply to the thermostat is disconnected.

3. Attach the new thermostat sub-base to the wall at the desired mounting location. Mount the sub-base to the wall before wiring the thermostat. Suggested Fuse To Protect Wiring Leading To Thermostat Not Found in Cool Only Applications FIGURE 1 7330D3351 Heat/Cool Thermostat Shown 7330D3361 Cool Only Model Has No Reference To Heat On Face Of Thermostat D. WIRING THE WALL THERMOSTAT TO PREVENT POSSIBLE DAMAGE TO THE EQUIPMENT OR PERSONAL INJURY DUE TO ELECTRICAL SHOCK, BE SURE THAT ALL ELECTRICAL POWER TO THE THERMOSTAT HAS BEEN DISCONNECTED BEFORE BEGINNING WIRING PROCEDURE. 1. Strip the 12 volt supply wire ends approximately 3/8 of an inch. 2. Use the Wire Cross Reference Chart and connect the appropriate conductor to the wire which protrudes from the back of the thermostat (See Figure 3). If this is a first time installation, note the thermostat wire color for future reference in order to properly connect the thermostat wiring to the ceiling assembly. 3. Attach the negative and positive 12 volt power supply wires to the appropriate wire on the thermostat. It is important to identify the positive and negative power supply wires before connecting to insure proper thermostat operation. If this is a replacement thermostat and there is no negative 12 VDC supply at the thermostat, a negative wire from the power supply to the thermostat must be added. 4. If a furnace system is to be operated from the thermostat, strip and attach the furnace system wires. 2

5. Gently push the excess thermostat wiring back into the wall opening. Because the wall may have a different temperature inside when compared to the outside, fill the wall opening with a non-combustible insulation. Insure that wires cannot contact screws or sharp edges in the wall cavity. 6. Snap the thermostat body onto the base. 7. Turn the thermostat system switch to the OFF position. 8. After the entire system (including the ceiling assembly and roof top air conditioner) has been properly installed, restore the electrical power to the thermostat. 3

OPERATION The chart below shows the system functions with the 7330D3351 thermostat. After the entire air conditioning system (and furnace system) is installed, check each position function. Disregard references to heat functions when using the 7330D3361 Cool Only thermostat. All cooling functions controlling to setpoint have a short cycle protection time delay of 3 minutes. There will be no delay if the cycle OFF time exceeds 3 minutes. * There is no heat switch or furnace function available with the 7330D3361 Cool Only thermostat. RV Products A Division of Airxcel, Inc. P.O. Box 4020 Wichita, KS 67204

1976D190 (5-01)