MODEL CX -WAC/HP AIR CONDITIONERS & HEAT PUMPS

Similar documents
MODEL IX-WAC AIR CONDITIONERS FOR HAZARDOUS & HIGHLY CORROSIVE AREAS

GREEN REFRIGERANT R-410A

FX5 Series Explosion-Proof Electric Air Heaters

MERIT SERIES Up Flow / Horizontal

MERIT Series R-410A - Upflow / Horizontal

50HS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION HEAT PUMP UNITS W/OPTIONAL ELECTRIC HEAT

MERIT Series R-410A - Upflow / Horizontal

48SS018, 024, 030, 036, 042, 048 & 060 STANDARD-EFFICIENCY COMBINATION GAS HEATING/ ELECTRIC COOLING UNITS

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

ABH BASIN HEATER CONTROLS PACKAGE. engineering data and specifications

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

CX1 ProVector Explosion-Proof Heaters

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

CF1 ProVector Explosion-Proof Heaters

PURGE/PRESSURIZATION SYSTEM

Assembly COM NO NC. Wiring configuration Wiring configuration. 120 VAC power supply (supply voltages 24 VDC and 240 VAC available upon request)

Capacity: 1.5 to 6.0 Ton

Brasch Hazardous Location Unit Heaters

Capacity: 1.5 to 6.0 Ton

VAC1 Series - Division 2 / Zone 2

VACPB1 Series - 60 Hz Models

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

VAC1 Series-Division 2 / Zone 2

PACKAGE AIR CONDITIONER

BARD MANUFACTURING COMPANY, INC. W24G-W60G Gas Heat/Electric Cooling Engineering Specification Guide

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

G Series SAVE THESE INSTRUCTIONS. (Model B) Convector Heater for Hazardous Locations GENERAL! INSTALLATION

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

Stars Management JLT SUBMITTAL. EXPLOSION PROOF ELECTRIC AIR HEATER (FX Series)

Heating Capacity - 23,700 to 220,000 Btuh Nominal Add-On Cooling - 2 to 5 Tons WATER HEATING / BOILERS CBWMV. Residential Hot Water Heat Air Handler

High Heat COP. High/Low Stage

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

13 GEP A L P - 1 A

Advance Release September 2009

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

PAC SERIES - 13 SEER SINGLE PACKAGED AIR CONDITIONER (GEN 3, STYLE A)

WALL-MOUNT HEAT PUMPS - (60HZ)

RGE 13 A T - 1 A

GREEN REFRIGERANT R-410A

RTXP2 Series - Division 1 OR 2 / Zone 0, 1,OR 2

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

PAJ3. Product Specifications

PGF SERIES 7-1/2 Ton. Belt Drive CONVERTIBLE SINGLE PACKAGE GAS/ELECTRIC UNIT

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

48TM GAS HEATING/ELECTRIC COOLING UNITS

MACH N-407 Heat Pump Air-Cooled Chiller

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

This parts list is current as of the above revision date. See for the current revision.

KIC Air Curtains. Technical Guide

HEATING & COOLING SPLIT SYSTEM HEAT PUMP & AIR CONDITIONER 14 SEER INTERTHERM SERIES

50TM COMBINATION HEATING/COOLING UNITS

General Description. Operation

SECTION AIR-COOLED SPLIT SYSTEM AIR CONDITIONING UNITS

Thermal Devices Inc. Mount Airy, Maryland USA Process Air and Radiant. ADH Typical Installation.

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

Portable Vertical Air-Conditioning and Heating Systems

FLD = Furnished by Trane U.S. Inc. / Installed by Equipment Submittal Page 3 of 13

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

Commercial High-Efficiency Condensing Units

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

ULTRA-SAFE Explosion-proof Duct Heaters

BARD MANUFACTURING COMPANY, INC. WG3S-WG5S 2-Stage Cooling with Gas Heat Engineering Specification Guide

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

COMPLETE WATER SOURCE HEAT PUMPS CATALOG

DARTMOUTH COLLEGE DESIGN March 15, 2003 & CONSTRUCTION GUIDELINES

48TF GAS HEATING/ ELECTRIC COOLING UNITS

FE1 Explosion-Proof Electric Air Heaters

MERIT SERIES Upflow / Horizontal

SPLIT SYSTEM COOLING 1½ 5 TON ALLEGIANCE 14 MODELS 4A7A C/30-060B American Standard Heating & Air Conditioning

50TM TFF COMBINATION HEATING/COOLING UNITS

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

SECTION CONVECTION HEATING AND COOLING UNITS

SECTION SPLIT-SYSTEM AIR-CONDITIONERS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

CROWN. Boiler Co. Santa-Fe Series. Hydronic Air Handlers INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

Toll-Free: TPI CORPORATION Hazardous Location Fan Forced Unit Heater

Explosion Proof Hazardous Location Roof Top A/C Units

GTIP60 ISO GT Series, Inch Pounds - 60 Hz GT (iso) Spec Guide Drawings Spec Sheets Low Temp Heating P/T Charts

8+* Bulletin No November 1997

Installation and Maintenance Manual Please retain this manual for future reference.

AIR HANDLER SPECIFICATION

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

PC SERIES 50 Hertz PRODUCT SPECIFICATIONS. Self-Contained Packaged Air Conditioners. 4 and 5 Ton [14.1 kw to 17.6 kw]

HVAC REPAIR/REPLACEMENT 07/18/12 SECTION HVAC - MAJOR EQUIPMENT

ACCESSORY KIT INSTALLATION INSTRUCTIONS

MAC N-407 Air-Cooled Chiller

JCseries EVAPORATIVE CONDENSER. engineering data

A. Section includes split-system air-conditioning units consisting of separate evaporator-fan and compressor-condenser components.

ULTRA-SAFE Explosion-proof Duct Heaters

Circulation Heaters Selection Guidelines

Air Cooled Split System Condensing Unit for Rooftop Systems and Air Handlers

This parts list is current as of the above revision date. See for the current revision.

GUIDE SPECIFICATIONS AQUARIUS ii

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

GUIDE SPECIFICATIONS AQUARIUS ii

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

UP to 14.5 SEER, PACKAGE AIR CONDITIONER UNIT, 2 to 5 TONS 208/230 Volt, 1 phase, 60 Hz REFRIGERATION CIRCUIT

Commercial High-Efficiency Condensing Units

Q-TEC QC-Series Chilled Water Air Conditioner

Transcription:

1.5, 2, 2.5, 3, 3.5, 4, 5 & 6 Ton Commercial Grade Wall Mounted ir Conditioners & Heat Pumps Unit pplication ebco Model CX-WC/HP is an electrically powered hazardous location climate control unit designed to cool permanent structures. The units are available in 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 5.0 and 6.0 tonnages and most units can be factory set, at time of order, to operate on 208/230 VC single phase, 208/230 VC three phase or 460 VC three phase power supplies. The unit is designed to have an external electrical rating approved for Class I, Division 2 / Zone 2, Groups, C, & D / II, II hazardous areas. In addition, the unit is available with a choice of two interior electrical ratings. The first interior electrical rating option is designed and approved for buildings classified as nonhazardous locations as a result of Type Z pressurization in accordance with the NEC - NFP 70, rticles 500 & 501 and the NFP 496. The second interior electrical rating option is rated and approved for Div. 2 / Zone 2, Groups,C, & D / II, II hazardous (classified) locations. Description MODEL CX -WC/HP IR CONDITIONERS & HET PUMPS FOR DIVISION 2 / ZONE 2 HZRDOUS LOCTIONS ECU Division Technical ulletin CX-WC/HP-R2.0 08/12 ebco Model CX-WC/HP Commercial Grade ir Conditioners are self-contained wall mounted units with all necessary components to supply a room or building with recirculated air that is temperature controlled and humidity limited. The HVC system features two isolated sections, stacked one atop the other. The lower section, known as the condenser compartment, contains the condenser coil, condenser fan motor, condenser fan and shroud assembly, compressor, and pressure sensors which supply the unit controls with signals to activate and deactivate the compressor and condenser fan. The upper section, known as the evaporator compartment, contains the evaporator coil, optional heater elements, an evaporator blower wheel and motor assembly, electrical controls and a return air filter element. The units are contained within either a 316 14 gauge stainless steel or 20 gauge sheet metal housing that features wall surface mounting flanges, ventilation grills on the condenser compartment, and doorway drip shield flanges. The units are intended for use in outdoor locations and feature a weather resistant paint finish, which can also be refinished with white enamel, but can also be painted any custom color requested. Model CX-WC/HP units are intended for use in areas where exposure to a severely corrosive atmosphere is considered unlikely or very infrequent. The unit bottom support bracket, return air filter grille, and supply air register are shipped loose in the crate, to complete field installation. In addition, custom supply ducts with registers can be furnished upon request to distribute air evenly to multiple rooms or the entire length of a large single room. C I NTERTEK LIS TED CM US Model CX-WC/HP G2 & 22 Units 6 Ton & Div.1 Units re Not ETL Certified 6 Ton Wall Mount Heat Pumps re NOT vailable 4725 Lawndale La Marque, TX 77568 PHN: (409) 935-5743 FX: (409) 938-4189 www.okbebco.com Copyright 2012- ebco Industries, Incorporated - ll Rights Reserved

Manufacturing Process Cross Sectional View Starting with documented instructions and a full inspection and operational test of the unit, ebco begins the conversion process in the evaporator compartment, where all electrical components and the evaporator fan are carefully removed and stored for later use. ll commercial grade fiberglass insulation is then removed from the bottom section of the evaporator compartment, and is replaced with industrial grade foil back insulation. In addition, a solid steel bottom plate with mounting rails are added to seal the compartment and accommodate electrical control enclosure mounting brackets. Moving to the condenser compartment, a special wiring enclosure is then fitted to the compressor, and sealed flex conduit and form seven conduit fittings are added to ensure that all high voltage wiring is suitable for a Div. 2 / Zone 2, Group,C, & D / II, II rea. Next, the condenser coil motor and fan blade are replaced with a Div. 2 / Zone 2 UL Listed TENV motor with hermetically sealed thermal overloads and an aluminum spark free fan blade. The unit is then made suitable for either a Nonhazardous or Div. 2 / Zone 2 building interior. For Div. 2 / Zone 2 interiors, the electrical controls and barriers for a Div. 2 / Zone 2 thermostat are installed in a NEM 7 explosion proof enclosure, along with sealed flex conduit, appropriate seals and an evaporator blower, modified to contain a Div. 2 / Zone 2 UL Listed TENV Motor with hermetically sealed thermal overloads and spark free aluminum fan blades. Finally, For Nonhazardous interiors, all electrical controls are placed in a NEM 12 enclosure and the original evaporator fan is reinstalled into the unit, along with jacketed wiring systems for component interconnection. The interior of the unit is silicone sealed at every point of body panel attachment and fitted with a special flange and rear door assembly to provide a positive seal against the entrance of flammable gases or vapors. ll units are then fully inspected and operationally tested to ensure quality of the final product. "22" & "G2" Unit Ratings The most distinguishing difference between CX- WC Models, besides the obvious difference of size, is the classification of the evaporator compartment. s noted above, since the units are intended for use in a Div. 2 / Zone 2, Group, C, & D / II, II Hazardous rea, the condenser compartment components and all associated wiring are rated for Div. 2 / Zone 2 reas. ut the evaporator compartment components are only exposed to the air which is recirculated within uilding. For this reason, ebco designs units that are suitable either for a Nonhazardous interior or a Div. 2 / Zone 2 interior. The units are distinguished by a segment of the Model Number that identifies the unit's electrical rating. rating of "22" represents a unit that is suitable for a Div. 2 / Zone 2 rea both inside and outside of the building or room. rating of "G2" represents a unit that is suitable for a Div. 2 / Zone 2 rea on the exterior of the building or room, but which is only suitable for a Nonhazardous rea within the room or building. The downgraded "G2" unit is therefore, by design, only suitable for building interiors that are rated Nonhazardous, but is offered at a significantly lower price than the "22" units. Optional Fresh ir Make-up Pressurization ir Cond. ir flow Div. 2 Evaporator Compartment Climate Controlled uilding or Room Div. 2 Interior tmosphere IMPORTNT "22" "21" & "2G" UNIT NOTES "22" Units are designed and approved for use on control rooms or buildings classified as Class I, Division 2 / Zone 2, Groups,C&D / II, II and contain no internal source of ignitable concentrations of gases or vapors (analyzer rooms). "22" Units are also designed and approved for use on analyzer rooms or buildings classified as Class I, Division 2 / Zone 2, Groups,C&D / II, II, if the room or building is ventilated in accordance with NFP 496 section 8.3.1. IMPORTNT "G2" & "G1" UNIT NOTES Operation & Service Initial start-up is accomplished by ensuring that the thermostat controller for the HVC system is set to the "off " condition. Power can then be applied to a main disconnect switch for the unit after any conditions such as building pressurization have been satisfied. The HVC system's thermostat can then be set to activate heating or cooling functions. During normal operation, the HVC system will cycle on and off as needed to meet thermal control demands. Power to the HVC system must be disengaged prior to accessing the HVC system evaporator compartment. Please contact a ebco Sales ssociate or refer to the installation, operation and maintenance manual for more information regarding operation. DIVISION I PPLICTION NOTE Type Y purging will be used to protect motors, compressor and conduit system on Units rated for Class I, Division 1, Group Hazardous reas. Contact a ebco Sales ssociate for information. "G2" Units are designed for use on structures with nonhazardous interior ratings as a result of Type Z pressurization in accordance with NFP 496. The structure must contain no internal source of ignitable concentrations of gases or vapors, e.g. analyzer rooms. "G2" Units must be powered by a circuit located after or separate from a disconnect switch for the pressurization unit, in accordance with NFP 496 section 5.4.9 Discharge ir Flow IMPORTNT "11" & " 21" UNIT NOTES "11 and 21" as well as "1G, G1 and 12" Units incorporate a Type "Y" pneumatic purging system to render all or some Division 2 rated motors and conduit systems suitable for a Division 1 Group C & D Hazardous reas. User must provide a clean source of instrument air or inert gas that is essentially free of any ignitable concentration of combustible gas, and operate purging system in complete accordance with manufacturer's instructions and NFP 496. ebco Industries, Incorporated Environmental Control Units Division Model CX-WC/HP R2.0 Page 2 of 8 Discharge ir Flow Return Div 2 Condenser Compartment "22" Unit Cut way View Interior & Exterior Rated Class I, Groups C&D / II, II, Division 2 / Zone 2 Optional Fresh ir Make-up Pressurization ir arrier Cond. ir flow Sealed Evaporator Compartment Climate Controlled uilding or Room Interior tmosphere Return Condenser Compartment "G2" Unit Cut way View Interior Rated Non Hazardous Exterior Rated Class I, Groups C&D / II, II, Division 2 / Zone 2

"1 & 2" Prefix Interior View "G" Prefix Interior View Sloped Top Evaporator Coil Drain Pan ir Flow Switch Division 2 / Zone 2 Evaporator lower General Purpose Evaporator lower (Optional Div. 2) Explosion Proof NEM 4 & 7 Control Enclosure NEM 4 Control Enclosure Condenser Coil The term "Prefix" above and below refers to a Unit's Electrical Rating "1 & 2" Prefix Controls "G" Prefix Controls VC Power Terminals Compressor Contactor Evaporator Fan Motor Cap. Thermostat Repeater Relay VC Power Terminals Thermostat Terminals Compressor Contactor * uxiliary Heater Element Contactors 24 VC Transformer Evaporator Fan Motor Control Card Intrinsically Safe Isolator 24 VC Transformer Intrinsically Safe Isolator ebco Industries, Incorporated Environmental Control Units Division Model CX-WC/HP R2.0 Page 3 of 8

"22" Unit with Optional Heat Strips "G2" Unit with Optional Heat Strips For "22" Units High Limit Switch For "G2" Units Only Finned Type Heater Elements For Division 2 reas Standard 5-20 Kilowatt Heater Elements for Nonhazardous reas IMPORTNT LOW TEMPERTURE OPERTIONS NOTES Units utilizing cooling cycle at or below 65 F outside ambient require factory installed low ambient control accessory for proper operation. Consult Factory for more information. "22" & "G2" Unit Condenser Compartment Wiring Feed-Through Hub Sealed Flex Conduit Evaporator Drain Pan's Drain Tube Division 2 TENV Motor with Hermetically Sealed Thermal Overloads and luminum Fan lade Compressor Wiring Junction ox Scroll Compressor Condenser Fan Interconnection Wiring Junction ox Heresite Coating** Non-Incendive Wiring to High Pressure & Low Pressure Switch Non-Incendive Wiring to Low mbient Pressure Switch Compressor & Condenser Fan ssembly Photos above represent HVC System Condenser Compartment with Division 2 Electrical Rating ebco Industries, Incorporated Environmental Control Units Division Model CX-WC/HP R2.0 Page 4 of 8

asic Unit Wiring Requirements & Compatible ccessories UILDING EXTERIOR From Customer Power Source ebco HVC Units "GG" General Purpose Interior General Purpose Exterior "G2" General Purpose Interior Class 1, Division 2, Exterior "G1" General Purpose Interior Class 1, Division 1, Exterior Wiring From CX-WC Unit Controls General Purpose Cable UILDING INTERIOR Model PT-C-G Programmable utomatic Changeover Thermostat for General Purpose reas (Humidity Control Feature vailable) Coiled Wire Heater Elements Internally mounted & Pre-Wired See Page 8 for vailable kw Ratings From Customer Power Source ebco HVC Units "2G" Class 1, Division 2, Interior General Purpose Exterior "22" Class 2, Division 2, Interior Class 2, Division 2, Exterior "21" Class 2, Division 2, Interior Class 1, Division 1, Exterior Wiring From CX-WC Unit Controls Non-Incendive Cable Model PT-C-H Programmable utomatic Changeover Thermostat for Division 2 reas (Humidity Control Feature vailable) Finned Tube Heater Elements Internally mounted & Pre-Wired See Page 8 for vailable kw Ratings From Customer Power Source ebco HVC Units "1G" Class 1, Division 1, Interior General Purpose Exterior "12" Class 1, Division 1, Interior Class 1, Division 2, Exterior "11" Class 1, Division 1, Interior Class 1, Division 1, Exterior Wiring From CX-WC Unit Controls Intrinsically Safe Cable Model MT-C-HM Intrinsically Safe Manual Thermostat for Division 1 reas Remote Heater Units For CX-WC/HP Div. 1 Units ebco Industries, Incorporated Environmental Control Units Division Model CX-WC/HP R2.0 Page 5 of 8

Unit Specifications Overall Dimensions: see page 7 Shipping Weights (lbs): 1.5 & 2.0 Ton Units 350 2.5 & 3.0 Ton Units 435 3.5, 4.0, 5.0 & 6.0 Ton Units 560 Operating Temp Ranges: -40 F - 125 F Power Wiring Conduit Entries: 3/4" FPT Thermostat Wiring Conduit Entries: 1/2" FPT T- Code Rating T3 Operating Voltages: 208/230 VC 1Ø 60 Hz * 208/230 VC 3Ø 60 Hz * 460/480 VC 3Ø 60 Hz ** 230 VC 3 3Ø 50 Hz ** 415 VC 3 3Ø 50 Hz * Voltage not available for 1.5 ton Units ** Voltage for Oversea's pplication Terms "Suffix and "prefix" below refer to Unit's Electrical Rating Component Specifications Condenser Fan Motor: TENV Cl. I, Div. 2, Gr., C & D "G" Prefix Evaporator lower Motor: General Purpose "2" Prefix Evp. lower Motor: TENV Cl. I, Div. 2, Gr., C & D HVC System Compressor: Scroll Style w/ Sealed Contacts "G" Prefix Control Enclosure: NEM 4 "1 & 2" Prefix Control Enclosure: NEM 4 & 7 Material Specifications Unit Housing & Door: Painted 20 Ga Galv. Steel 14 Ga 316 Stainless Steel "G2" Rear ccess Door: Painted 14 Ga Galv. Steel "G2" ccess Door Fasteners: Cast Zinc ody / Zinc olt Evaporator Coil: Copper & lum. "G2" Evaporator lower Motor: Painted Steel Housing "G2" Evaporator lower Wheels: Galvanized Steel "22" Evaporator lower Motor: Painted Steel Housing "22" Evaporator lower Wheels: luminum Compressor ody: Painted Carbon Steel Condenser Fan Motor: Painted Steel Housing Condenser Fan lade: luminum Condenser Coil: Copper & lum. Unit & Device Nameplates: Reverse Print Lexan Control Enclosure: Cast luminum and/or Polycarbonate Elect. Enclosure & Fittings: Cast Zinc, lum., & Other Coating vailable Lexan is a registered trademark of the General Electric Corporation Standard Finish: ebco Finish: Custom Finish: Housing Finish Specifications ard Factory Finish 2 mil Tan Enamel on all exterior surfaces except Unit back 1 mil Wash Primer & 3 mil White Urethane coating on exterior housing surface and all exposed Interior metal brackets, parts and components per written customer specification Unit Tons 1.5 2.0 2.5 3.0 3.5 4.0 5.0 6.0 Unit Minimum Circuit mpacity Chart 208 VC/1Ø 208 VC/3Ø 460 VC/3Ø ux. Heat Kw ux. Heat Kw ux. Heat Kw 0 5 8 10 15 20 0 6 9 15 18 0 6 9 15 16 30 46 56 - - - - - - - - - - - 21 30 46 56 - - 15 22 - - - 10 12 - - 24 32 48 58 84-18 24 33 51-11 12 17 26 29 32 48 58 84-23 24 33 51-12 12 17 26 33 33-59 85 111 25-34 53 62 13-18 27 37 37-59 85 111 29-34 52 62 14-18 27 41 41-59 85 111 28-34 53 62 15-18 27 49 49-59 85 111 43-43 53-23 - 23 27 WHP Minimum Circuit mpacity Chart 208 VC/1Ø 208 VC/3Ø 460 VC/3Ø Unit ux. Heat Kw ux. Heat Kw ux. Heat Kw Tons 0 5 8 10 15 20 0 6 9 15 18 0 6 9 15 1.5 16-58 - - - - - - - - - - - - 2.0 24-65 - - - 17 35 - - - 11 21 - - 2.5 3.0 3.5 4.0 24 50-76 - - 18 36 45 - - 11 20 25 30 29 55-81 84-23 41 50 60-12 21 25 26 36 62-88 88-26 44 53 53-13 22 26 26 37 63-89 89 111 29 47 56 56 62 14-27 27 5.0 41 67-93 93 111 28-55 55 62 16-28 28 The charts above DO NOT included amp draw from a humidistat (if included). SEE UNIT MODEL IDENTIFICTION TG FOR CTUL ELECTRICL LODS Unit Mounting & Cut Out Template Note: The mounting flange is shipped mounted to the unit shipping pallet. Note: olt hole diameter is 0.375" I Template Dimensions by Tonnage Size C D SUPPLY OPENING RETURN OPENING Mounting Flange TONS C D E F G H I 1.5 & 2.0 12 5.5 34.125 20.125 8.125 20.375 12.125 28 5 2.5 & 3.0 12 5.625 39.125 28.125 8.125 17.75 14.125 28.875 5 3.5 4.0 16 2.875 43 30.125 10.125 29.75 16.125 27 1.875 * 5.0 6.0 21 3 43 30.125 10.125 29.75 16.125 37 1.875 C L E F G H * 5 Ton Wall Mount Heat Pumps re Housed In 6 Ton Housing, Refer To 6 To Dimensions For 5 Ton Heat Pumps ebco Industries, Incorporated Environmental Control Units Division Model CX-WC/HP R2.0 Page 6 of 8

Unit Housing Dimension Diagrams "22" Model CX-WC Standard Right Hand Configuration Shown (Left Hand Configuration vailable t Customers Request) E S 1.5 D M L I F H C Optional Pressurization air either side on request N G Q K O "G2" Model CX-WC Standard Right Hand Configuration Shown (Left Hand Configuration vailable t Customers Request) E S ECO 1.5 D M L R H C I Optional Pressurization air either side on request N G K O Individual Unit Dimensions by Tonnage Size TONS C D E F G H I J K L M N O P Q R S 1.5 & 2.0 7.875 19.875 11.875 17.125 34.875 18.25 25.75 70.5 20.75-28 34 4.75 12 5-35.25 44 33.2 2.5 & 3.0 7.875 27.875 13.875 17.125 39.875 18.25 25.75 70.5 18-28.75 39 4.75 12 5-35.25 44 37.875 3.5 4.0 9.875 29.875 15.875 22.5 43.875 19 31.625 84.875 30-27 43 2 16 1.875-41.25 53 42 * 5.0 6.0 9.875 29.875 15.875 22.5 43.875 19 41.625 94.875 30-37 43 2 16 1.875-42.7 58 42 * 5 Ton Wall Mount Heat Pumps re Housed In 6 Ton Housing, Refer To 6 To Dimensions For 5 Ton Heat Pumps ll Dimensions shown in inches. ll Dimensions are shown for reference purposes only and subject to change without notice. ebco Industries, Incorporated Environmental Control Units Division Model CX-WC/HP R2.0 Page 7 of 8

Coiled Wire Heater Elements "GG, G1, & G2" Rated Units Only - - - - - 60 Hz UNIT VOLTGES - - - - - UNIT - - - - - C - TONS 1Ø 208/230 VC 3Ø 208/230 VC 3Ø 460 VC 1.5 C15G2H05 > Last Two Digits "05" = Kilowatts C15G2H08 C15G2H10 2 C20G2H05 C20G2H06 C20CG2H06 C20G2H08 C20G2H09 C20CG2H09 C20G2H10 C20G2H15 C20CG2H15 2.5 C25G2H05 C25G2H06 C25CG2H06 C25G2H08 C25G2H09 C25CG2H09 C25G2H10 C25G2H15 C25CG2H15 C25G2H15 3 C30G2H05 C30G2H06 C30CG2H06 C30G2H08 C30G2H09 C30CG2H09 C30G2H10 C30G2H15 C30CG2H15 C30G2H15 3.5 C35G2H05 C35G2H09 C35CG2H09 C35G2H10 C35G2H15 C35CG2H15 C35G2H15 C35G2H18 C35G2H20 4 C40G2H05 C40G2H09 C40CG2H09 C40G2H10 C40G2H15 C40CG2H15 C40G2H15 C40G2H18 C40G2H20 5 C50G2H05 C50G2H09 C50CG2H09 C50G2H10 C50G2H15 C50CG2H15 C50G2H15 C50G2H18 C50G2H20 6 C60G2H05 C60G2H09 C60CG2H09 C60G2H10 C60G2H15 C60CG2H15 C60G2H15 C60G2H18 C60G2H20 Finned Tube Heater Elements "2G, 21, 22, 1G, 12, & 11" Rated Units Only - - - - - 60 Hz UNIT VOLTGES - - - - - UNIT - - - - - C - TONS 1Ø 208 /230 VC 3Ø 208/230 VC 3Ø 460 VC 1.5-3 F3022H03 F3022H03 3.5-6 F6022H05 F6022H05 F60C22H05 Heater Element Notes: For 50 Hz Unit Voltages, please consult factory sales agent. For isolated radiant heater units, refer to the Remote Heater Unit Specification ulletin. For information regarding duct mounted heating units and auxiliary forced air heating units, please contact factory sales agent. Unit Thermostats Model Number Intended Unit rea Classification PT-C-G "GG, G2 & G1" Units General Purpose PT-C-H "2G, 22" & 21" Units C1, D2, Gr., C & D MT-C-HM "1G, 12" & 11" Units C1, D1, Gr. C & D Notes: Thermostats with a "M" Suffix are manually operated and non-programmable. Thermostats with an "" suffix are programmable with automatic switch-over between Heating and Cooling Modes. IMPORTNT NOTES ll specifications subject to change without notice. Warranty & Liability policies available upon request. Model Number Designations Typical Model- CX-WC- -20--G2-H3-0 Model CX - Commercial Grade Style WC - Wall Mount ir Conditioner WHP - Wall Mount Heat Pump Custom Configurations * 0 - Optional Features Optional pressurization * P - Pressurization Unit Tonnage WC ** Total TU WHP ** TU Cool WHP *** TU Heat 1.5-1.5 Tons 16,400 16,400 16,000 2.0-2.0 Tons 24,000 23,600 24,000 2.5-2.5 Tons 29,400 29,800 29,000 3.0-3.0 Tons 35,400 34,600 35,000 3.5-3.5 Tons 41,000 42,000 42,000 4.0-4.0 Tons 47,000 46,000 44,000 5.0-5.0 Tons 55,000 54,000 54,000 6.0-6.0 Tons 68,000 - - Voltage ***** - Single Phase 208/230 VC 60 Hz - Three Phase 208/230 VC 60 Hz **** C - Three Phase 460 VC 60 Hz **** D - Three Phase 230 VC 50 Hz **** Class I Electrical Rating Interior Exterior G - General Purpose G - General Purpose 1 - Div. 1 GRP C & D 1 - Div. 1 GRP C & D 2 - Div. 2 GRP, C, & D 2 - Div. 2 GRP, C, & D Zone 2 GRP II+H2 T3 Zone 2 GRP II+H2 T3 Heating Equipment ***** G - General Purpose 0 - None 8-8 kw H - Hazardous 3-3 kw 9-9 kw 5-5 kw 10-10 kw 6-6 kw 15-15 kw Options 0 - No Option Standard Model Selection Notes: This symbol indicates a place holder, if data tag has no info here, then the unit is not equipped with optional equipment, accessory, or configuration. * Remove this section from model structure if not required ** TU cool rating @ 95 F outside ambient *** TU Heat rating @ 47 F outside ambient *** Note: Units utilizing cooling cycle were normal conditions are below 30 F auxiliary heat may be required or suggested. Consult Factory for more information. **** Voltage option not available for 1.5 ton Units ***** dditional sizes and voltages available. (Consult factory) 6 Ton Units re NOT ETL listed Division 1 Units are not ETL listed. Division 1 Units are self-certified in compliance UL Standards. ebco Industries, Incorporated Environmental Control Units Division Model CX-WC/HP R2.0 Page 8 of 8