Hot-air generator. Operation manual (Basis operation) TAKETSUNA MANUFACTORY CO., LTD. Please read this without fail before use.

Similar documents
Please send to the customer who is used this operation manual without fail. Operation manual Basis operation edition

Hot-air generator. Final edition of Electric hot-air generator!! Catalog No. 4 TAKETSUNA MANUFACTORY CO., LTD. Hot-air generator.

AUR300C, AUR350C. Advanced Ultraviolet Burner Controller

High pressure hot-air generator KD-series

Original instructions. Operation Manual & Cautions

KTIR AIR CONDITIONER SERIES TROUBLESHOOTING

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

WATER BATH MODEL TBS451PA OPERATION MANUAL

Advanced Ultraviolet Burner Controller

Pressure-Resistant and Explosion-Proof Electric Contact Pressure Gauges and Pressure Switches

RE-PR3-E-27 3-Phase Panel Mount 27kW

Contents. 11. Preamble. 12. For the safe use. 13. Appearance. 14. Connecting the sources of electricity. 15. Caution for use before the operation.

Customized Industrial Products

Part 3 Troubleshooting

INSTRUCTION MANUAL. Laboratory Equipment Pty Ltd Ph: Fax:

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOYG07LEC AOYG09LEC AOYG12LEC AOYG14LEC

AUR300C. Advanced Ultraviolet Burner Controller

CORONA BURNER CONTROLLER INSTRUCTION MANUAL RCF15 EXCLUSIVE FOR FLAME ROD. Corona Corporation

SYSTEM Inverter Air Conditioners

WET & DRY GARAGE VAC 20L CAPACITY WATT 1.5M MOTOR TANK STEEL HOSE KP702 ON BOARD ACCESSORY STORAGE SUCTION STAINLESS

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type) VAM150FC VAM250FC

Model:DKG610(V)/650(V) Model:DKG810(V)/850(V)

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G24LFL AO*G24LFCC AO*G30LFT

Model : CHB Series CHUNGHO C.A. CO., LTD. Head office / Factory Seowoon-Dong, Gyeyang-Gu, Incheon, Korea. com

E11 Indoor Board Failed to Receive Signal from Signal Output Board III - 65 E12 Automatic Address Setting is in Progress: Automatic Address Setting

SPLIT TYPE ROOM AIR CONDITIONER. WALL MOUNTEDtype INVERTER. Models Indoor unit Outdoor unit AOU 9RLFW1 AOU12RLFW1 ASU 9RLF1 ASU12RLF1 R410A

WiseBath WSB Shaking Water Bath Operation Manual (Version 1.4.0)

Example of Applications and Parameter Functions

Contents. 11. Preamble. 12. For the safe use. 13. Appearance (Body). 4. Before connecting sources of electricity. 15. Points of warning and caution.

R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AO*G09LTCN AO*G12LTCN AO*G14LTCN

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit AOU9RLS2H AOU12RLS2H AOU15RLS2H

Submersible Garden Pump USER'S MANUAL

Fire Extinguishing Control Panel INSTRUCTION MANUAL. Revision 8/ Instruction Manual Page 1 Revision 8/01.17 of 63

INSTRUCTIONS FOR THD-U SERIES HOT AIR MATERIAL DRYERS

Ultrasonic Humidifier TALL. Product Manual

Operation Manual (Version 1.4.4)

Instruction Manual for Dust Collector

SERVICE Manual FREE JOINT MULTI AIR CONDITIONER

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Safety Information. Functional Description. Operation. DANGER Do not touch or contact the input/output terminals because it may cause electric shock.

Mold Temperature Controller GMC (L, H, A) U. Instruction Manual

Forced Convection Constant Temperature Oven. Instruction Manual

Mobile Type Air Conditioner

NOTICE . SAFE SERVICING PRACTICES. Electric Wall Oven with Electronic Oven Control

MCLX HX. Spiral Pump(Mechanical Seal Type) Mold Temperature Controller. Summary. Performance Curve. Lift

SERVICE Manual SYSTEM AIR CONDITIONER INDOOR UNIT GH052EAM GH070EAM OUTDOOR UNIT UH052EAMT UH070EAMT. 1. Product Specifications

DRI-AIR INDUSTRIES, INC. ARID-X10C FLOOR MOUNT DRYER OPERATING MANUAL

MARUYASU INDUSTRIES CO.,LTD.

MICRO CONTROLLER S Z SERIES

ACORE Filtration Co.,Ltd provides engineering,

A/C-HEATER SYSTEM - MANUAL

INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS

DOMESTIC ICE MACHINE USER INSTRUCTION MANUAL MODEL TS-061

C. Shop Drawings: For boilers, boiler trim, and accessories. Include plans, elevations, sections, details, and attachments to other work.

Mold Temperature Controller

Water Circulator (Chiller) & Cold Trap

1. The structure and its description

CERTIFIED UNDER CANADIAN AND AMERICAN NATIONAL STANDARDS: CSA C22.2 No-46 / UL 2021 BEF33H & BEF40H ELECTRIC FIREPLACE

MODEL: SP12C7. (Portable 4 gas detector) Operating Manual

Part 5. Troubleshooting. 1. Normal Air Conditioner Phenomenon Air Conditioner Protection in Common

SYSTEM Inverter Air Conditioners

Owner s Manual CS

WALL MOUNT ELECTRIC FIREPLACE OWNERS MANUAL

Owner s Manual SPLIT-TYPE ROOM AIR CONDITIONER

Simple Self-Diagnosis by Malfunction Code

Motion Sensor Oscillating Heater with Digital Control

CAUTION. Installation Manual

H&H Asia Group Limited

TC-150 CONVEYORIZED OVEN. OPERATION AND MAINTAINANCE MANUAL Ovens with Omron PLC and Touchscreen

SX-300 SX-500 SX-700

OPERATION MANUAL. Total Heat Exchanger HRV (Heat Reclaim Ventilation) (Ceiling mounted duct type)

CERAMIC HEATER MODEL: HT-1003 READ AND SAVE THESE INSTRUCTIONS

Faster Temperature (& Humidity) Chamber

DESIGN & TECHNICAL MANUAL

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 350 SERIES CIRCULATION HEATERS

SERVICE MANUAL 42QHF009DS* 42QHF012DS* 42QHF018DS* 42QHF022DS* 38QUS009DS* 38QUS012DS* 38QUS018DS* 38QUS022DS* Indoor unit.

LA type soldering iron controller

OPERATION MANUAL. StableTemp Economy Mechanical Convection Oven. Model : ,-90,-91,-92,-93,-94

DESIGN & TECHNICAL MANUAL

Smokeless Roaster Operational Manual

Trouble Shooting Guide FAA, 3-phase (D3631)

Portable Space Ceramic Heater

INSTALLATION AND OPERATION MANUAL

TEMPERATURE CONTROLLER

AC-12200E Portable Air Conditioner

Specifications. Table of contents. 2:Specification. 3:Composition. 4:Instruments outside figure

DRI-AIR INDUSTRIES, INC. HA750B B HOT AIR DRYER OPERATING MANUAL

AFD Industrial Dehumidifier Series

FAR INFRARED RAYS HEATER

JDW Leaf Blower. EQ750 - Assembly Instructions. Please Read All Instructions Thoroughly Before Starting Assembly

TECHNICAL DATA & SERVICE MANUAL MTF94C5TAA

General safety precautions English

General safety precautions English

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Install Guide CT100. Caution. Caution

6-1 Installing Batteries 6-2 Automatic Circuit/Reset Feature 6-3 Feature Sensitivity Adjustment

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

Vacuum Cleaner. user manual. Please read the User Manual thoroughly before operating the vacuum. For indoor use only.

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

Transcription:

Please send this operation manual to the final customer without fail. Preservation Hot-air generator Operation manual (Basis operation) Please read this without fail before use. This time, thank you very much for purchasing the hot-air generator. Please confirm whether the model, type, voltage and the order article are not wrong by the name board of this machine. Basis operation method of the hot-air generator is entered to this operation manual. Please see the main operation manual about Installation, Piping, Power supply, Service terminal, Abnormal detection, and Convenient function. TSK High pressure TSK Hot-air generator hot-air generator TSK-18 TSK-22H4 TSK-23 33 TSK-32H5 TSK-42 52 52HT TSK-52H6 TSK-56 TSK-53H7 TSK-62 72 TSK-62H8 TSK-82 TSK-72H9 TSK-92 102 TSK-82H10 TSK-121 Platinum catalytic oxidation type deodorization device HJ-1.5 TAKETSUNA MANUFACTORY CO., LTD.

1.Usually operation 1 Please turn on the factory power supply (the first power supply). STOP lamp is lighted, and NFB is flickered to SV dept., OFF to PV dept. 2 Please turn on the breaker (NFB) of the this machine. Present temp. is displayed to SV dept., 0 to PV dept., and 60(Frequency) to the air volume adjustment dept. You can not operate in this condition. TSK-18 is displayed 2 by the factory power supple turns on. 2nd, before setting value is displayed to SV and air volume control. Air volume control is not displayed about TSK-H type. 3 When BLOW switch was pushed BLOW lamp (Green) is lighted and blow operation is started. Setting of air volume control (Setting of the frequency) It can change in 30Hz to 60Hz range by the up down key. Please adjust the air volume by the dumper for the air volume control about TSK-H type. (Air volume control frequency is not displayed.) But, air volume can be adjusted by frequency setting about type with the inverter. (Option) Temp. does not reach until max. temp. if air volume is set up to the minimum air volume (30Hz) when the condition of hot-air generator is non-load. This is because the minimum of the rotation speed of the motor is set up by the cooling effect of the blower motor is considered. In this case, please establish the dumper to inlet, and please squeeze the air volume by the dumper in minimum air volume seting condition. 4 When HOT-AIR switch was pushed HOT-AIR lamp (Orange) is lighted and hot-air operation is started. Setting of hot-air temp. It can change in 0 to 350 C range by the up down key. Max. setting temp. of TSK-51HT is 500 C. ON/OFF of the heater is displayed by the illumination and flickering of the heater lamp. -1-

2.Timer operation and Timer stop Please set up hot-air temp. and air volume control before the timer operation. Please set up the timer in operation stoppage condition. (Timer can not set up during blow and hot-air operation.) Timer operation (ON TIMER) 1 Please push ON TIMER switch. ON TIMER (Green) lamp is lighted, and 00.00. is flickered to timer display dept. Or the before setting time is lighted. 2 Please set up it to optional time by the up down key. Timer can be set up until 99 hours 59 minutes. After setting, please separate the hand from the up down key. Flickering changes to illumination 2 seconds later and setting value is registered. 3 Please push HOT-AIR switch. Time counting (Reduction of timer setting) is started (Dot display flickering). Hot-air operation is started when the time counting becomes 00.00. HOT-AIR lamp (Orange) is flickered during time counting, and is changed to illumination after the hot-air operation start. Timer display becomes to 00.00 after the completion of time counting. Timer operation and time counting are stoppedby pushing STOP switch. Timer stop (OFF TIMER) 1 Please push OFF TIMER switch. OFF TIMER (Green) lamp is lighted, and 00.00. is flickered to timer display dept. Or the before setting time is lighted. 2 Please set up it to optional time by the up down key. Timer can be set up until 99 hours 59 minutes. After setting, please separate the hand from the up down key. Flickering changes to illumination 2 seconds later and setting value is registered. 3 Please push HOT-AIR switch. Time counting (Reduction of timer setting) is started (Dot display flickering) and hot-air operation is started. Hot-air operation is stopped when the time counting becomes 00.00. HOT-AIR lamp (Orange) is lighted during hot-air operation, and is changed to flickering after the hot-air operation completion. Timer display becomes to 00.00 after the completion of time counting. Timer operation and time counting are stoppedby pushing STOP switch. -2-

3. In the case that Temp. alarm is set up Alarm signal can be output in the case that discharge hot-air temp. exceeded an optional regular range to setting temp. Please use if necessary. (Setting at the time of the shipment is ineffective.) 1 Please continue to push MODE switch. (About 2 seconds) A1 is displayed to PV dept., 0 to SV dept. 2 Please set up optional temp. by the up down key. After setting, please return to the display of usually operation condition by pushing the MODE switch 3 times. 3 Please start hot-air operation. TEMP. ALM lamp (Red) is lighted more than +10 C or less than -10 C of setting discharge temp. if 10 is set up, and the alarm is output from the service terminal. (Except when temp. rises at the time of the hot-air operation start.) Operation of this machine is not stopped by the temp. alarm. Temp. alarm output is ineffective when setting of temp. alarm is 0. Temp. alarm output is output of TSK-18-33 and TSK-22H4-32H5 as the unvoltage contact signal (Contact capacity AC250V 3A DC30V 3A) from the temp. alarm output terminal T and A, and TSK-41-121 and TSK-52H6-82H10 is from terminal B6. 4. In the case that External temp. control is used Hot-air generator can be controlled by the signal of the temp. controller that was established to the outside. In this case, please use as the discharge temp. upper limiter the temp. controller of this machine. 1 Please continue to push MODE switch. (About 2 seconds) A1 is displayed to PV dept., 0 to SV dept. 2 Please push the mode key 1 time once again. SSC is displayed to PV dept., OFF to SV dept. 3 Please change OFF of SV dept. to ON by the up key. After setting, please return to the display of usually operation condition by pushing the MODE switch 2 times. (OFF is ineffective.) 4 Please start hot-air operation. EXT. CNTL lamp (Orange) is lighted irrespective of the input of the external temp. control in the case that external temp. control setting was changed to ON. Please input SSR drive reverse action output (DC12-24V) to external temp. control input terminal E.C+ and E.C- about the external temp. control input of TSK-18-33 and TSK-22H4-32H5, and to terminal A4-A5 about TSK-41-121 and TSK-52H6-82H10. -3-

5. In the case that External sensor is used Temp. of the place that parted can be controlled by the external sensor. Please set up after the external sensor is connected to the external sensor input terminal of the service terminal. 1 Please continue to push MODE switch. (About 2 seconds) A1 is displayed to PV dept., 0 to SV dept. 2 Please push the mode key 2 times once again. ESN is displayed to PV dept., OFF to SV dept. 3 Please change OFF of SV dept. to ON by the up key. After setting, please return to the display of usually operation condition by pushing the MODE switch 1 time. 4 Please start hot-air operation. EXT. SENSOR lamp (Orange) is lighted in the case that external sensor setting was changed to ON. Please connect without mistaking the external sensor to external sensor input terminal E.S+ and E.S- about TSK-18-33 and TSK-22H4-32H5, and to terminal A6-A7 about TSK-41-121 and TSK-52H6-82H10. Barnout is operated and this machine can not operate in the case that the external sensor is set up in condition without the external sensor being connected. 6. In the case that external operation is used Hot-air generator can to be operated and controlled ON/OFF of the heater by the signal from the outside. 1 Please continue to push EXT. RUN switch in stoppage condition. (About 2 seconds) EXT. RUN lamp (Orange) is lighted. 2 Please operate by the external operation signal. BLOW lamp (Green) is lighted and this becomes blow operation when external operation signal is ON and enternal heater ON/OFF signal is OFF. HOT-AIR lamp (Orange) is lighted and this becomes hot-aur operation when external operation signal is ON and enternal heater ON/OFF signal is ON. Hot-air generator can not operate for 20 seconds when it is stopped by the external operation. (BLOW lamp or HOT-AIR lamp is flickering at the time of the waiting condition of operation, and it is operated once again 20 seconds later from stoppage.) Life of the relay of the inside becomes short when the external heater is turned ON/OFF frequently. So, the case, please use the external temp. control. HOT-AIR switch and BLOW switch are ineffective at the time of external operation mode. (No-control) Please push STOP switch for the reset of the external operation. And, the timer can not operate by the external operation. Please input the unvoltage contact output (terminal voltage less than DC12V 2.5mA) to external operation terminal E.R and externai heater ON/OFF terminal E.H about the external operation and external heater ON/OFF of TSK-18-33, and to terminal A1 and A2 about TSK-41-121. -4-

7. In the case that the cooling operation function is used Cooling operation function can be used in the case that the hot-air generator was selected the operation or stop by the timer. Blow operation in the optional time is conducted after the hot-air operation by the timer was conducted, and operation is Cooling operation of our hot-air generator is not necessary in order that the snapping of a wire of the heater is prevented because watt density is set up low. Please use this cooling operation function for burn prevention od piping after operation stop and cooling of the drying heating product after work. 1 Please continue to push the up key of timer while pushing the MODE switch in stoppage condition. T- 2 is displayed to PV dept., OFF to SV dept. 2 Please change SV to ON by the up key, and please push MODE switch 1 time. 00.00. is flickered to timer display dept. 3 Please set up optional cooling time by the up down key. After setting, please return to the display of usually operation condition by pushing the MODE switch 1 time. 4 Please push OFF TIMER switch and please set up hot-air operation time. 5 Please push HOT-AIR switch. T ime counting is started. (Dot display flickering) And, hot-air operation is conducted. HOT-AIR lamp (Orange) is lighted during hot-air operation. Cooling operation (Blow operation) by the timer is started after the hotair operation is ended by the timer. And, BLOW Lamp (Green) is lighted during cooling operation. Cooling operation is stopped when time counting became 00.00. And, Blow lamp is flickered. Timer operation is stopped by pushing STOP switch. (Timer setting time returns to the initial setting value.) -5-

Inquiry regarding the hot-air generator.. Homepage www.taketsuna.co.jp Or TAKETSUNA MANUFACTORY CO., LTD. Overseas dept. TEL +816-6785-6001-6-

Attention on use Please confirm without fail before use. For the hot-air generator is used without malfunctioning Important matters that demand special attention that became the cause of malfunction that occurred in the past is entered. Please inquire with the use method of your company. Please attach the demi-filter or CR-filter without fail to the suction side of the hotair generator. Please clean always the filter that is used or wire net of the hot-air generator inlet. (Standard equipment) Heater inside is overheated by the clogging of the filter and the hot-air generator may can not operate. Hot-air generator malfunctions when these adhered to the controller inside of the hot-air generator in the case that dust, mine dust, floating objects that pass electricity of carbon fiber, oil, lampblack, oil mist, moisture, and vapor is included to the atmosphere of the setting place of the hot-air generator. Hot-air generator can not use in corrosiveness of combustibility gas, inflammability gas, plating, and atmosphere. Please consult us in the advance. Please turn ON the breaker (NFB) of the hot-air generator constantly. Please do not turn ON/OFF as the operation switch. Electron devices of the inside are damaged by serge voltage. Leakage of the hot-air is occured without fail on the characteristic of the flexible hose in the case of the piping by the flexible hose to the outlet and inlet of hot-air generator. Electron devices inside the operation panel are damaged by the hot-air of the high temp. that leaked flows backward to the hot-air generator inside. So, please execute the glass tape for the air leakage prevention that was enclosed to the outlet and inlet. Input terminal A1-A10 and output terminal B8-B10 is malfunctioned by the voltage is applied. And, output terminal B1-B7 is malfunctioned by the voltage more than the rating is applied. Please do not unite or wire that was adjoined the wiring of the service terminal with the power supply line, high tone wave line. Electron devices of the inside are damaged by noise. Please do not stopped the hot-air generator with the electromagnet contact device that was established to the first side of the hot-air generator. Electron devices of the inside are damaged by serge voltage. The thunder serge that occurred by falling of a thunderbolt becomes a cause to the wrong action, damage, and fire accident of the hot-air generator. Please attach the arrester without fail and please perform the falling of a thunderbolt measure in the case that the hot-air generator is used in the place where receives the influence of falling of a thunderbolt. Please use the commercial power supply (50/60Hz) that has the sine wave-like to the power supply of the hot-air generator. Please do not use the power supply that has the distortion wave including a high tone wave from the frequency transformation device absolutely. Electron devices of the inside are damaged by high tone wave and noise. -7-