stationary dose rate measuring systems

Similar documents
Battery-operated, hand-held alarm and measuring instruments for radiation protection

PORTABLE ISOTOPE IDENTIFIER Search Tool / Sample Counting System

Radiation Measuring Equipment. for Radio-Iodine Therapy, PET-centers, Radiopharmacy, Nuclear Medicine, Radioimmune Therapy

Portable Alpha/Beta Continuous Online Air Monitor (CAM)

Operation Manual. Scinto doserate meter with scintillation detector (NaI)

ß-Aerosolmonitor FHT 59 C

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

VM-3000 Mercury Vapor Monitor

The Modular System for Radioactivity Measurements FH 40 G/GL FHT 6020

Mercury Vapor Monitor VM-3000

Radioactivity dosimeter RD01. User's Manual

A bright alpha numeric display and the simplified keypad (three buttons) allow the operation even under harsh conditions.

Aer 5200/5300. Data Sheet Aer 5200/5300. Portable Alpha/Beta Continuous Online Air Monitor (CAM) Closer to your application

requirements. Serial: USB or RSXXX Bluetooth GPS/GSM Ethernet Standard or rugged desktop or laptop PC or tablet; Android smartphone or tablet

Pressure measuring instruments

VM-3000 Mercury Vapor Monitor

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

HIGHLY SENSITIVE FOR NUCLEAR POWER PLANTS Real-Time Continuous Water Monitor

Radiation Monitoring System RMS

Operating Manual UV Monitor UVT 18

NEXT GENERATION DRINKING WATER RADIATION SAFETY MONITOR

A Continuous Air Monitoring Sampler for 125 I - RIS-125

NUCLEAR INDUSTRY STANDARD PROCESS Radiological Protection. Level 3 Information Use

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

UV - Monitor UVT 16. Use. Description

RC4000 Radiation Detection System

SEAWATER RADIATION DETECTION SYSTEM WATER PROTECTION

Continuous Gas Analyzers, extractive

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Laboratory Air circulated Refrigerator/Deep Freezer TC Two-door (2 independent temperature ranges)

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

Use this Specification Template to develop a specification to be used for requesting a quote or defining a job work description.

THX-DL Data Logger USER & INSTALLATION MANUAL V

PRESENTATION OVERVIEW OF THE DIFFERENT MODELS MONITORS

Medical Air circulated Refrigerator TC (2 independent temperature ranges), also in accordance with DIN 58345

LAUNDRY MONITORING SYSTEM Model # LIM-64S

MultiFix Central unit

Microtherm Heat Stress WBGT

Plasma Freezer with air circulation TC 516 acc. to DIN 58375

Dew point. Special features: Dew point monitoring DS 400. Technical data DS 400. Technical data FA 510

External Dimensions: B = 750 mm D = 700 mm H = 2100 mm. Internal Dimensions: B = 600 mm D = 580 mm H = 1270 mm. Temperaturerange: 2 C to 20 C


Chromatographic Air circulated Refrigerator, two-door TC 603

RIID capability in the palm of your hand

Thermo Scientific Aerosol Monitor FHT 58 S Technical Specification ZT-221E

Laboratory Refrigerator/Deep Freezer TC 802

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA

radiometric detection technologies

ADVANCED RADIATION DETECTION EQUIPMENT

Danfoss gas detection units

PHOENIX L300i New Standards in Helium Leak Testing The next Generation

Plant growth chambers

SONAPHONE E. ATEX Certificated for the Use in Areas with Risk of Explosion. Features:

PM1703MO-1A PM1703MO-1B PERSONAL COMBINED RADIATION DETECTOR/DOSIMETER. Operation Manual

On the job around the clock 24/7: Fire detection systems

Dew point set DS 400

MultiFix Central unit

Advanced Radiation Detection Equipment

Solution F2. Fire Alarm Control Panels one step ahead.

Using the GammaRAE II Responder Personal Radiation Detector and Dosimeter in One. Firmware Version 3.00 D August 2006

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

MODEL 23 AND 23-1 ELECTRONIC PERSONAL DOSIMETER. August 2017

ICH750L. Climate Chamber. Product specification

561-MB256 plus. Intruder alarm control panel. Performance features

Gas Controller Module GC-06

Dosimeters/Survey meters

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Multi-Gas-Controller MGC2

Product data sheet Palas Fidas 200 S

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Controller Specification Sheet

Remote. control unit. accessories. Leak detector SmartTest. Remote control unit for SmartTest. Remote. Vacuum analysis and measurement

Seismic Countermeasures for Environmental Radiation Monitoring System

Power Flame Incorporated

Videomatrix SIMATRIX 648

Radiation Monitoring Systems

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

ZXe INTELLIGENT MULTI PROTOCOL FIRE ALARM CONTROL PANEL

S.E.A. GmbH - Your Partner for

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Very High Sensitivity Multi-Zone Metal Detector for Law Enforcement and Correctional Facilities.

ADOS Biogas 905. Multi-channel Gas Analyser. A D O S GmbH Instrumentation and Control Trierer Str FRG

Constant climate chambers. KBF 240 (E5.2) - Constant climate chamber. Performance features and equipment:

Constant climate chambers

AIR or STACK MONITOR NOBLE GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE. Optional Alpha, Tritium, Carbon-14

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Portable Survey Instruments NISP-RP-01

LUDLUM MODEL 3276 SERIES FRISKER/AREA MONITOR USER S MANUAL. November 2017 Serial Number: and Succeeding Firmware: 49830n30 and Higher

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Tender Specifications. Supply of radiation detection equipment for EUSECTRA training centre Lot 2: Backpack for portable radiation detection system

A T L A S - SolarClimatic Test Cabinet SC 2000 MHG

AERIAL RADIATION DETECTORS

Call stations and extensions

Constant climate chambers

Constant climate chambers

RadEye B20 RadEye B20-ER Multi-Purpose Survey Meter

Dräger Polytron 8000 Stationary gas detector (EC)

E21.X.01.6C-05 Operating Manual EB2000 MC page 1. Operating manual EB2000 MC. for up to 9 sensor modules. Version 3.0

Transcription:

stationary dose rate measuring systems A L M O 1 - A L M O 3 - A L M O 6 A L M O 1 Alarm -channel, stationary dose rate measuring system with external detector Fields of application workplace and room monitoring, e.g. on hot cells system monitoring, e.g. in isotope production ward and/or patient monitoring in nuclear medicine/radiation therapy monitoring and selection in sorting boxes for radioactive waste exhaust air monitoring monitoring of test facilities in non-destructive material testing warehouse monitoring, e.g. collection sites for radioactive was Performance features μ-controller-based measurement electronics digital measurement value information on large-area, illuminated LCD display externally connectable detector (GM-counter tube, NaIdetector..) with integrated high voltage generation and electronics automatic detector identification, calibration data are read out by the measurement electronics, allowing simple replacement of the detector detector can be set up in a distance of 100 m from measurement electronics via cable 2 freely definable alarm thresholds easy-to-operate measurement system with user guidance ergonomically shaped housing, desktop or wall version various optical/acoustic alarm units connectable serial data interface for measurement data transmission and storage on external PC system software for continuous dose rate measurement, incl. data storage.

Technical data Type: Alarm Monitor ALMO 1 Electronics: μ-controller-based measurement electronics 1 detector connectable Display: LCD display (128 x 64 pixels with LED background illumination in continuous operation mode Keyboard: membrane keyboard Housing: 200 x 150 x 75 mm (L x W x H) available as wall or desktop housing Power supply: 100-240 V ~, 50-60 Hz Consumption: 15 W Alarm: optical and acoustic, external alarm unit as an option Temperature range: 0 C to +40 C Interfaces: switch output for 3-level lamp 2 switch outputs, potential-free, max. 24 V, 1 A serial interface RS 232 or RS 422 (as an alternative) Detectors The following detectors can be used as standard: Geiger-Müller counter tubes Type 18 550 DE/CE*, measurement range approx. 1 μsv/h - 20 msv/h Type 18 509 DE/CE*, measurement range approx. 50 μsv/h - 1 Sv/h Type 18 529 DE/CE*, measurement range approx. 200 μsv/h - 10 Sv/h * ambient dose equivalent H *(10) NaI-scintillation detector* NaI 1 x 1.5, measurement

A L M O 3 Monitor Multi-Channel, Stationary Dose Rate Monitoring System with External Detectors. Field of Application Workplace and room monitoring, e.g. on hot cells System monitoring, e.g. in isotope production Ward and/or patient monitoring in nuclear medicine/radiation therapy Monitoring and selection in sorting boxes for radioactive waste Exhaust air monitoring Monitoring of test facilities in non-destructive material testing Warehouse monitoring, e.g. collection sites for radioactive waste Performance Features Microcontroller-based measurement electronics Digital measurement value information on large-area, illuminated LC display Simultaneous measurement value display of all connected probes Measurement value display of the dose rate in n/μ/msv/h with auto ranging function Externally connectable detectors (GM counter tubes, Nal detectors) with integrated high voltage generation and electronics Automatic detector identification, calibration data are read out by the measurement electronics, allowing simple replacement of the detectors Mixed operation of different detectors possible Detectors can be set up in a distance of up to 100 m from the measurement electronics via cable connection 2 freely definable alarm thresholds per probe Monitoring of the service life of the counter tube (%) Easy-to-operate measurement system with user guidance Ergonomically formed housing, can be used as desktop or wall housing 2 insulated switch outputs per probe (one each per alarm threshold) Different visual/acoustic alarm signalling units can be connected Serial data interface for data transfer and storage on external PC system Software for continuous dose rate measurement, including data storage

Technical Data: Type: Alarm Monitor ALMO 3 Electronics: μ-controller-based measurement electronics connection of max. 3 detectors Display: LC display 4 x 20 characters, with LED background illumination in continuous operation mode Keyboard: Membrane keypad Housing: 302 x 272 x 101 mm (W x D x H) can be used as wall or desktop housing Power supply: 230 V, 50 Hz Consumption: max. 60 W Alarm: visual and acoustic, external alarm unit as an option Temperature range:0 C to + 50 C, 0-95% relative humidity Interfaces: 2 insulated switch outputs per detector (max. 24 V, 1 A) e.g. for 3-step signal lamp, in addition 1 sum output 1 RS 232 or RS 422 interface The following detectors can be used as standard: Geiger----Müller Counter Tubes. Type 18 550 DE, measurement range approx. 1 μsv/h - 20 msv/h Type 18 509 DE, measurement range approx. 50 μsv/h - 1 Sv/h Type 18 529 DE, measurement range approx. 200 μsv/h - 10 Sv/h Type 18 526/36 as pulse probes Nal Scintillation Detector. Nal 1 x 1.5", measurement range 40 nsv/h - 2 msv/h.

A L M O 6 Alarm Monitor 6-channel, stationary dose rate measuring system with external detectors. Fields of application. workplace and room monitoring, e.g. in hot cells system monitoring, e.g. in isotope production ward and/or patient monitoring in nuclear medicine/radiation therapy monitoring and selection in sorting boxes for radioactive waste exhaust air monitoring monitoring of test facilities in non-destructive material testing warehouse monitoring, e.g. collection sites for radioactive waste Performance features. μ-controller-based measurement electronics digital measurement value information on large-area, illuminated LC display measurement value display of dose rate in n/μ/msv/h with auto ranging function membrane keyboard with indication of the switching status of the traffic light relays externally connectable detector (GM counter tube, NaI detectors) with integrated high voltage generation and electronics automatic detector identification, calibration data are read out by the measurement electronics, allowing simple replacement of the detector detector can be set up in a distance of 100 m from measurement electronics via cable 2 freely definable alarm thresholds per probe easy-to-operate measurement system with user guidance ergonomically shaped housing, desktop or wall version optional emergency power supply 8 x 2 switch outputs, 8 x potential-free and 8 x potential-free or 24 Volt supply (can be set via menu) various visual/acoustic alarm units can be connected 2 (3) interfaces: o Interface A: USB, RS-232, RS-422 or RS-485 can be selected via menu. o Interface B: RS-232, RS-422 or RS-485 can be selected via menu. o Ethernet (in preparation) software for continuous dose rate measurement, including data storage (in preparation) 3 languages can be set via menu: German, English, French data storage of the last 100 alarms

Technical data Type: Alarm monitor ALMO 6 Electronics: μcontroller-based measuring electronics 6 detectors can be connected Display: Graphic-LCD-screen (128 x 64 pixels) with LED illumination during continuous use Keyboard: Membrane keyboard Housing: 280 x 300 x 120 mm (L x W x H) available as wall or desktop housing Power supply: 100-240 V, 47-63 Hz Power consumption: max. 60 W Alarm: optical and acoustic, optionally external alarm units, 2 thresholds for each probe, Freely definable Temperature range: 0 C till + 40 C Relays: Switching capacity: max. 24 V, 1 Ampere per channel Current for traffic light, acoustic and additional elements If not switched potential-free: 24 V, total current of all 6 channels max. 1500 ma Interfaces: A: switchable: USB, RS-232, RS-422 or RS-485 B: switchable: RS-232, RS-422 or RS-485 Detectors: The following detectors can be used as standard: Geiger----Müller counter tubes. Type 18 550 DE/CE*, measurement range approx. 1 μsv/h - 20 msv/h Type 18 509 DE/CE*, measurement range approx. 50 μsv/h - 1 Sv/h Type 18 529 DE/CE*, measurement range approx. 200 μsv/h - 10 Sv/h * ambient dose equivalent H*(10) NaI----scintillation detector*. NaI 1 x 1.5, measurement range 40 nsv/h - 200 μsv/h * max. cable length 20 m