Installation Instructions VITOTRONIC 200

Similar documents
Installation Instructions VITOTRONIC 300

Operating Instructions and User s Information Manual for use by engineers and heating contractors VITOTRONIC 100 IMPORTANT

Installation and Service Instructions SM1 SOLAR CONTROL MODULE IMPORTANT. Read and save these instructions for future reference.

Installation Instructions. Replacement of Control Console, Part No , Safety and Installation Requirements

Start-up/Service Instructions for use by heating contractor. VITOCELL r 300-V VITOCELL r 300-B IMPORTANT

Technical Data Manual

Installation Instructions for use by heating contractor. VITOCELL r 300-H CAUTION IMPORTANT. Read and save these instructions for future reference.

Installation Instructions for use by heating contractor. VITOCELL r 100-B CAUTION IMPORTANT. Read and save these instructions for future reference.

Installation Instructions for use by heating contractor. VITOCELL r 100-V CAUTION IMPORTANT. Read and save these instructions for future reference.

Service Instructions for use by heating contractor

Installation, Operating and Service Instructions for use by heating contractor. VITOCELL r 300-W CAUTION IMPORTANT

Operating Instructions and User s Information Manual VITOROND 200 WARNING WARNING IMPORTANT. Read and save these instructions for future reference.

Technical Data Manual Model Nos. and pricing: see Price List

Installation and Operating Instruction Supplement Use in conjunction with the original technical literature supplied by Riello. Riello Burner WARNING

Leading Word on Lag Modules

Technical Data Manual Model Nos. and pricing: see Price List

Operating Instructions VITOCROSSAL 300 WARNING WARNING IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

Installation and Service Instructions. VITOTRONIC r 100 IMPORTANT. Read and save these instructions for future reference.

Communication. Versatronik 581 & 581D LON Communication Gateway. Technical, Installation and Configuration Information. Cautionary Statement

VITOSOL r DHW SOLAR PACK

Service Instructions for use by heating contractor VITOROND 200 IMPORTANT. Read and save these instructions for future reference.

Installation and Service Instructions for use by heating contractor. VITOTRONIC r 200 VITOTRONIC r 300-K IMPORTANT

2 PREPARE THE OPENING

Installation Instructions for use by heating contractor VITOCROSSAL 300 IMPORTANT. Read and save these instructions for future reference.

Installation Instructions for use by heating contractor. Common Venting with Flue Vent Damper IMPORTANT

Technical Data Manual Model Nos. and pricing: see Price List VITOCROSSAL 300

INSTALLATION INSTRUCTIONS

Installation, Service and Operating Instructions. Viessmann AirflowPLUS IMPORTANT. Read and save these instructions for future reference.

VIESMANN. Installation instructions VITODENS 200-W. for contractors

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Operating Instructions VITOTRONIC 200 VITOTRONIC 300-K IMPORTANT. Read and save these instructions for future reference. for use by heating contractor

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions

Installation Instructions for use by heating contractor. VITODENS r 222-F IMPORTANT. Read and save these instructions for future reference.

for use by heating contractor Vitotronic 300 Type GW2B IMPORTANT Read and save these instructions for future reference.

MULTI-TEMPERATURE LOOP CONTROL BOARD INSTRUCTIONS

Operating Instructions. VITODENS r 200 Series With Vitotronic 200 HO1B Controls WARNING WARNING IMPORTANT

Models CHB/CCB APPLICATION GUIDE WALL MOUNTED GAS BOILER

Installation Instructions for use by heating contractor. Vitodens Common Venting System IMPORTANT

Installation Instructions

Table of Contents. Important Safety Instructions. WARNING: If the instructions contained in this manual are not followed

Flow Factor ~

Installation Instructions

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

Use & Care Manual. Electric Tankless Water Heaters. With Installation Instructions for the Installer AP15447 (10/10)

Operating Instructions for use by heating contractor. VITOTRONIC r 100 VITOTRONIC r 300-K IMPORTANT

Installation GUIDE VDWU524SS VDWU524WSSS FDWU524WS FDWU524 VDWU324SS FDWU324

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 222-F

Some models are supplied with a protective film on steel and aluminium parts. This film must be removed before installing/using the appliance.

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

Installation Instructions

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

WAIWELA SERIES-TWO WATER HEATERS

BESF Box Ventilator USA CAN. Product Information. Mechanical Installation. ... Chapter 3. Electrical Installation. ... Chapter 4

Technical Data Manual Model Nos. and pricing: see Price List. VITODENS r 200-W

Installation Instructions

INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION INSTRUCCIONES DE INSTALACIÓN

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

DOUBLE DISHDRAWER TM DISHWASHER

Installation Instructions

Cedarbrook Sauna + Steam Family owned and operated since 1971

T4398A,B Precision Electric Heating Thermostat

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

Installation Instructions Induction Cooktop

SYSTEM CONTROL KIT Model: CK-41P

OPERATING AND INSTALLATION MANUAL

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

136"ElectricCooktop. nstructlons _,00, JP961, JP968, JP969, ZEU769. I Iinstallation. -&WARNING - This appliance must be properly grounded.

Installation Instructions

Service Instructions for use by heating contractor VITOCROSSAL 200 IMPORTANT. Read and save these instructions for future reference.

Low Water Cutoff (LWCO) IQ Option Card p/n , for Hot Water Boilers

ЭКСПЛУАТАЦИЯ И МОНТАЖ ПРОТОЧНЫЕ ВОДОНАГРЕВАТЕЛИ С ЭЛЕКТРОННЫМ УПРАВЛЕНИЕМ

RSIF power venter USA CAN READ AND SAVE THESE INSTRUCTIONS! Installation and operation manual. Product information Chapters 1 + 2

Installation Instructions

Service Manual Electric Cooktop

OPERATING AND INSTALLATION MANUAL

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

INSTALLATION INSTRUCTIONS and OPERATING MANUAL. *Aquastat is a registered trademark of Honeywell International, Inc.

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-214(C) Series 61 Low Water Cut-Off OPERATION

VIESMANN. Installation instructions. Extension EA1. Safety instructions. for contractors. Part no

Installation in Standard & Variable Speed Indoor Air Handlers IMPORTANT

be liable for any other loss or damage, whether direct, indirect, incidental or consequential.

Crown Boiler Company

WATER-TUBE POOL HEATERS

136"ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded.

RAB10 Series Two-pipe Fan Coil Room Thermostat with Manual Changeover

Installation and Service Instructions for use by heating contractor VITODENS 100-W IMPORTANT. Read and save these instructions for future reference.

CAUTION. Installation Manual

ignored. Denotes content that may result in bodily injury and physical damage when ignored.

Application Guide. Vitodens 100-W B1HA/B1KA Residential Boiler

Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

Installation Instructions

INSTALLATION INSTRUCTIONS FOR 6532 SERIES PACKAGE HEAT PUMP

Transcription:

Installation Instructions Please file in Service Binder Vitotronic 200 Model KW2 Weather-responsive indoor/outdoor, digital boiler control for heating systems with one or more heating circuits VITOTRONIC 200 Certified as a component part of Viessmann boilers only

Safety Instructions Safety, Installation and Warranty Requirements Please ensure that these instructions are read and understood before commencing installation and operation. Failure to comply with the instructions listed below and details printed in these instructions can cause product/property damage, severe personal injury, and/or loss of life. Ensure all requirements below are understood and fulfilled (including detailed information found in manual subsections). Licensed professional heating contractor The installation, adjustment, service, and maintenance of this equipment must be performed by a licensed professional heating contractor. Please see sections entitled Safety and Important Regulatory and Installation Requirements. Advice to owner Once the installation work is complete, the heating contractor must familiarize the system operator/ultimate owner with all equipment, as well as safety precautions/requirements, shut-down procedure, and the need for professional service annually before the heating season begins. Product documentation Read all applicable documentation before commencing installation. Store documentation near boiler in a readily accessible location for reference in the future by service personnel. Warranty Information contained in this and related product documentation must be read and followed. Failure to do so renders warranty null and void. For a listing of applicable literature, please see section entitled Safety. 2

Contents Important Precautions Safety... 4 Page Important Regulatory and Installation Requirements... 5 General Information About these Installation Instructions... 5 Heating System Types Application Example 1 System with one heating circuit without mixing valve. 6 Application Example 2 System with one heating circuit with mixing valve... 7 Application Example 3 System with one direct-connected heating circuit without mixing valve and one heating circuit with mixing valve... 8 Electrical Connections Vitotronic Connections... 9 Low water cut-off (LWCO) connections... 11 Application of Strain Reliefs to Cables... 12 Sensors... 13 Outdoor temperature sensor... 13 Boiler temperature sensor... 14 DHW tank temperature sensor... 14 Pumps (accessory)... 16 120 VAC pumps... 16 Burner Connection(s)... 17 Settings Fixed High Limit... 19 Adjustable High Limit... 21 Installation Boiler Coding Card... 21 Connecting Top Part of Control Unit... 22 Opening the Control Unit... 23 Appendix Post-Installation... 24 Checklist... 24 Start-up and adjustments... 24 Service binder... 24 Technical Data... 24 3

Important Precautions Safety Take note of all symbols and notations intended to draw attention to potential hazards or important product information. These include WARNING, CAUTION, and IMPORTANT. See page 5 for details. Approvals Viessmann boilers, burners and controls are approved for sale in North America by CSA International. Codes The installation of this unit shall be in accordance with local codes. In the absence of local codes, use: CSA C22.1 Part 1 and/or local codes in Canada National Electrical Code ANSI/NFPA 70 in the U.S. Always use latest editions of codes. Please carefully read this manual prior to attempting installation. Any warranty is null and void if these instructions are not followed. For information regarding other Viessmann System Technology componentry, please reference documentation of the respective product. We offer frequent installation and service seminars to familiarize our partners with our products. Please inquire. Working on the equipment The installation, adjustment, service, and maintenance of this product must be done by a licensed professional heating contractor who is qualified and experienced in the installation, service, and maintenance of hot water boilers. There are no user serviceable parts on the boiler, burner, or control. Ensure main power supply to equipment, the heating system, and all external controls has been deactivated. Close main oil or gas supply valve. Take precautions in both instances to avoid accidental activation of power during service work. The completeness and functionality of field supplied electrical controls and components must be verified by the heating contractor. These include low water cut-offs, flow switches (if used), staging controls, pumps, motorized valves, air vents, thermostats, etc. WARNING Turn off electric power supply before servicing. Contact with live electric components can cause shock or loss of life. Technical literature Literature applicable to all aspects of the Vitotronic 200: - Technical Data Manual - Installation Instructions - Service Instructions - Operating Instructions - Instructions of other Viessmann products utilized and installed - Installation codes mentioned in this manual Leave all literature at the installation site and advise the system operator/ultimate owner where the literature can be found. Contact Viessmann for additional copies. 4

Important Regulatory and Installation Requirements Important Precautions / General Information Power supply Install power supply in accordance with the regulations of the authorities having jurisdiction or, in the absence of such requirements, in accordance with National Codes. Viessmann recommends the installation of a disconnect switch to the 120 VAC power supply outside of the boiler room. The installer must provide maximum 15 A overcurrent protection for the 120 VAC power supply (fuse or circuit breaker). Workingwithanopencontrol No static discharge to the internal componentry must ever occur when workingwithopenedcontrol equipment. About these Installation Instructions Take note of all symbols and notations intended to draw attention to potential hazards or important product information. These include WARNING, CAUTION, and IMPORTANT. See below. WARNING Indicates an imminently hazardous situation which, if not avoided, could result in death, serious injury or substantial product/property damage. CAUTION Indicates an imminently hazardous situation which, if not avoided, may result in minor injury or product/property damage. IMPORTANT Warnings draw your attention to the presence of potential hazards or important product information. Cautions draw your attention to the presence of potential hazards or important product information. Helpful hints for installation, operation or maintenance which pertain to the product. This symbol indicates that additional, pertinent information is to be found in column three. This symbol indicates that other instructions must be referenced. 5

Heating System Types Application Example 1 System with one direct-connected heating circuit without mixing valve Boiler with Vitotronic 200 Domestic hot water storage tank Vitotrol, Switching Module-V or KM-BUS Expansion Module for the connection of several KM-BUS participants Heating circuit without mixing valve Power/Pump Module Low water cut-off (LWCO) Connections Outdoor temperature sensor Boiler temperature sensor DHW tank temperature sensor KM-BUS participant Expansion module for 2-stage/modulating burner 20-1 Heating circuit pump DHW pump (accessory) DHW recirculation pump (field supplied where required) Power supply (120 VAC, 60 Hz) Burner, 1st stage *1 Burner, 2nd stage/modulating *1 Required Equipment Description Qty Part No. Vitotronic 200 1 Z001 230 Available System Accessories Vitotrol remote control Room temperature sensor Switching Module-V for expanding the range of control functions Sensor/burner fault indication *1 Included in standard equipment KM-BUS Expansion Module Flue gas temperature sensor 6

Heating System Types Application Example 2 System with one heating circuit with mixing valve Boiler with Vitotronic 200 Domestic hot water storage tank Vitotrol, Switching Module-V or KM-BUS Expansion Module for the connection of several KM-BUS participants Heating circuit with mixing valve Power/Pump Module Low water cut-off (LWCO) Connections Outdoor temperature sensor Supply temperature sensor (accessory) Boiler temperature sensor DHW tank temperature sensor Return water temperature sensor (accessory) *2 KM-BUS participant Expansion module for 2-stage/modulating burner 20-2 Heating circuit pump mixing valve circuit DHW pump (accessory) DHW recirculation pump Power supply (120 VAC, 60 Hz) Burner, 1st stage *3 Mixing valve actuator (accessory) Burner, 2nd stage/modulating *3 Required Equipment Description Qty Part No. Vitotronic 200 1 Z001 230 Mixing Valve Actuator Accessory Kit (mixing valve actuator and supply temperature sensor) 1 7133 390 Available System Accessories Vitotrol remote control Room temperature sensor Return water temperature sensor Switching Module-V for expanding the range of control functions Sensor/burner fault indication KM-BUS Expansion Module Flue gas temperature sensor *1 Flow check valve only required if connection located at coupling. *2 In connection with underfloor heating when control measures supply and return water temperatures. *3 Included in standard equipment. 7

Heating System Types Application Example 3 System with direct-connected heating circuit without mixing valve and one heating circuit with mixing valve Boiler with Vitotronic 200 Domestic hot water storage tank Vitotrol, Switching Module-V or KM-BUS Expansion Module for the connection of several KM-BUS participants Heating circuit 2 with mixing valve Heating circuit 1 without mixing valve Power/Pump Module Low water cut-off (LWCO) Connections Outdoor temperature sensor Supply temperature sensor (accessory) Boiler temperature sensor DHW tank temperature sensor Return water temperature sensor (accessory) *2 KM-BUS participant Expansion module for 2-stage/modulating burner 20-1 Heating circuit pump 20-2 Heating circuit pump mixing valve circuit DHW pump (accessory) DHW recirculation pump Power supply (120 VAC, 60 Hz) Burner, 1st stage *3 Mixing valve actuator (accessory) Burner, 2nd stage/modulating *3 Required Equipment Description Qty Part No. Vitotronic 200 1 Z001 230 Mixing Valve Actuator Accessory Kit (mixing valve actuator and supply temperature sensor) 1 7133 390 Available System Accessories Vitotrol remote control Room temperature sensor Return water temperature sensor Switching Module-V for expanding the range of control functions Sensor/burner fault indication KM-BUS Expansion Module Flue gas temperature sensor *1 Flow check valve only required if connection located at coupling. *2 In connection with underfloor heating when control measures supply and return water temperatures. *3 Included in standard equipment. 8

Electrical Connections Vitotronic Connections The illustration below shows the bottom part of the control unit as viewed from rear. 20-2 120 VAC connectors Interconnections Power/Pump Module 20-1 Boiler circuit pump 20-2 Mixing valve pump DHW pump (accessory) DHW recirculation pump (field supplied) Power supply Mixing valve actuator (accessory) External equipment, e.g. additional safety equipment Burner connections Burner connections IMPORTANT The 120 VAC connections are interface connections to the Power/Pump Module. Do not connect any external equipment directly. Low voltage connectors Outdoor temperature sensor Supply temperature sensor (accessory) Boiler temperature sensor DHW tank temperature sensor Flue gas temperature sensor (accessory) Return water temperature sensor (accessory) KM-BUS (accessory) e.g. for the connection of Vitotrol remote control Expansion module for 2-stage or modulating burner (included in standard boiler equipment) IMPORTANT Take notice of shape and orientation of low voltage connectors when inserting into sockets at rear of control! 9

Electrical Connections Vitotronic Connections (continued) See following page for a description of all hard-wired equipment and additional information. Vitotronic boiler control (view from rear) Power/Pump Module (wall-mounted) Connections for plug-in equipment Connections for hard-wired equipment N L L N L N L N L N L N 10

Electrical Connections Vitotronic Connections (continued) Legend Power supply 120 VAC, 60 Hz, 1 Ph Provide 15 A overcurrent protection and disconnect means! Circulating pump system 1 Heating circuit without mixing valve 120 VAC, 1 Ph, 3 A max. Circulating pump for DHW tank 120 VAC, 1 Ph, 3 A max. Circulating pump for domestic hot water recirculation 120 VAC, 1 Ph, 3 A max. Circulating pump system 2 Heating circuit with mixing valve 120 VAC, 1 Ph, 3 A max. Viessmann mixing valve actuator (optional) IMPORTANT Ensure that main power supply to the Power/Pump Module contains overcurrent protection with a maximum rating of 15 A. This equipment must be grounded. Ensure that the following wires are not interchanged: L and N L: LINE N: Neutral G: Ground WARNING Low water cut-off (LWCO) connections 1. Run 3-wire cable between low water cut-off and Power/Pump Module. 2. Remove jumper on Power/Pump Module board (LWCO connection). 3. Connect wiring as shown. 4. Check LWCO function after installation is complete. Low water cut-off (typical) Contact closes on water 11

Electrical Connections Application of Strain Reliefs to Cables The strain relief clamps are supplied in the accessory pack. 1. Remove breakouts as necessary. 2. Mount lower portion of the strain relief clamp. 3. Insert the cable in the bushing and secure the wires to the plug. Insert bushing into clamp and plug into socket. 4. Fasten top portion of strain relief clamp. IMPORTANT An additional strain relief is not required for cables which incorporate a molded strain relief clamp. 12

Electrical Connections Sensors Outdoor temperature sensor IMPORTANT 1. 4. 5. 3. The outdoor temperature sensor should be mounted 6.6 to 8.2 ft./2 to 2.5 m above ground on the north or northwest wall of the building and for buildings with multiple floors, in the upper part of the second floor. The sensor must not be placed above windows, doors, air vents or immediately underneath a balcony or drainage pipes. The outdoor temperature sensor must not be plastered or painted over. If mounting on an unplastered wall, allow room for plaster or remove sensor before plastering wall. 1. Remove sensor housing. 2. 2. Secure wall-mount base to wall (cable inlet opening to the bottom). 3. Pass cabling through openings in the electrical connection section and the supplied cable bushing. IMPORTANT Do not run cable next to line voltage cables. 4. Connect cable wires to terminal. Cable: max. 115 ft./35 m long, AWG copper. 5. Mount outdoor temperature sensor housing. Outdoor temperature sensor 6. Connect the cable wires from the outdoor temperature sensor to terminals 1 and 2 on plug (the wires are interchangeable). 7. Insert plug into socket 1 and apply strain relief to the cable. 13

Electrical Connections Sensors (continued) Boiler temperature sensor The boiler temperature sensor is installed at the same time as the boiler insulation. Insert plug into socket 3 (see page 9) and insert the molded strain relief clamp. DHW tank temperature sensor Heating systems without domestic hot water heating Do not connect the DHW tank temperature sensor to the control unit. Heating systems with domestic hot water heating 1. Install the DHW tank temperature sensor. Installation Instructions for domestic hot water tank IMPORTANT When installing the DHW tank temperature sensor in tanks from other manufacturers, ensure that sensor firmly contacts the sensor well wall. IMPORTANT Ensure that the maximum permissible domestic hot water temperature is not exceeded. If necessary, install an additional safety high limit or a tempering valve of approved type. 2. Insert plug into socket 5 ; insert molded strain relief clamp. 14

Electrical Connections Sensors (continued) Sensor connections 145 15 3 5 1 191 2 17 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Mixing valve circuit A B C D E F A Flue gas temperature sensor B Boiler temperature sensor C Tank temperature sensor D Outdoor temperature sensor (wires may be interchanged) Installation point for outdoor temperature sensor North or north-western wall, 2 to 2.5 m / 6.6 to 8.2 ft above ground level; in multi-storey buildings, in the upper half of the second floor Not above windows, doors or ventilation outlets Not immediately below balcony or gutter Do not render over E Supply temperature sensor F Return temperature sensor Connection 2-wire cable with a maximum length of 35 m / 115 ft and a cross-section of 1.5 mm 2 (copper) 15

Electrical Connections Pumps (accessory) All circulation pumps can be hard-wired to the terminal strip of the Power/Pump Module. Prewired Viessmann circulation pumps can be plugged into the respective Rast-5 terminals on the Power/Pump Module. Available pump connections 20-1 Boiler circuit pump 20-2 Mixing valve pump DHW pump DHW recirculation pump See pages 6, 7 and 8. For underfloor heating system only An adjustable high limit (AHL) must be provided additionally. Install the fixed high limit in the heating supply pipe downstream of the mixing valve and the heating circuit pump. See pages 19 and 21 for installation details. 120 VAC pumps (prewired) WARNING ONLY Viessmann prewired (plug-in) circulating pumps must be used. Do not connect an additional pump to the respective hard-wired terminal if prewired pumps are used. 1. Insert supplied strain relief through Power/Pump Module breakout and fasten with nut. 2. Connect the Rast-5 connector to the respective plug-in terminal on the Power/Pump Module. 16

Electrical Connections Burner Connection(s) The burner cable is included in the standard boiler equipment. Terminal codes L Line via safety high limit Ground conductor to the burner N Neutral conductor to the burner T1, T2 Control circuit S3 Connection for burner fault B4 Connection for operating hours counter The Vitotronic 200 is prewired with the Viessmann quick-connect plug-in system. 1. Connect the Rast-5 plug-in connector to the main circuit board of the control. 2. Connect 7-pole plug to the counter plug of the burner. Or if installing a wall vent system (accessory), connect 7-pole plug to counter plug of wall vent system. Refer to technical instructions of the burner and/or wall vent system. WARNING Do not connect the 41-plug from the boiler control directly to the burner if a wall vent or flue damper / vent damper is installed. To control (Rast-5 plug-in connector) To burner or vent system ( plug-in connector) See technical instructions of the vent system. 17

Electrical Connections Burner Connection(s) (continued) Electrical connection of 2-stage or modulating burners Terminal codes T6, T7, Control circuit 2-stage T8 burner or modulation controller (via two-point controller with 2-stage operation; via three-point controller with modulating operation) 8 Signal direction: Control unit burner 7 Signal direction: Burner control unit The connection is made via the expansion module for a 2-stage/modulating burner. Installation Instructions of boiler, Installation Instructions of expansion module for a 2-stage/modulating burner To control unit To burner Enclosure with potential-free burner control output 18

Settings Fixed High Limit The fixed high limit (FHL) is factory preset to 230 ºF/110 ºC. Adjustment to 212 ºF/100 ºC 1. Remove the fuse. 2. Unclip the cover at the four snap-in clips and remove. Make: Etheco Make: EGO 3. Pull the front panel behind the cover upwardsandswingopentotherear. 4. Turn the slotted screw at rear of fixed high limit until the slot points to 212 ºF/100 ºC (once adjusted, the fixed high limit cannot be reset to 230 ºF/110 ºC). 5. Put the front cover back in place and replace fuse. 6. Check the box on page 24 of this manual to confirm that the adjustment was made. Slotted screw CAUTION If adjusted to 212 F/100 C, do not If adjusted set the adjustable to 212 ºF/100 high limit ºC, do not above 165 F/75 C. 19

Settings Fixed High Limit (contd.) Adjustment to 100 ºC (JUMO) The fixed high limit is factory preset to 230 ºF / 110 ºC. 2. 1. 5. 6. 4. 3. CAUTION If adjusted to 212 ºF / 100 ºC do not set the adjustable high limit above 167 ºF / 75 ºC. 20

Settings/Installation Adjustable High Limit The adjustable high limit (AHL) is factory preset to 165 ºF/75 ºC. Do not set the adjustable high limit above 165 ºF/75 ºC if the fixed high limit has been set to 212 ºF/100 ºC. Adjustment to 189 ºF/87 ºC 1. Using a suitable screwdriver, lever out selector knob behindthe flip-down cover. 2. Using a pair of pointed pliers, break off the respective cams on the dial. 3. Install selector knob, so that the marking is between 75 and 90. Turn selector knob fully clockwise. 4. Check the box on page 24 of this manual to confirm that the adjustment was made. IMPORTANT If the system is operated in conjunction with a domestic hot water storage tank, ensure that the maximum permissible domestic hot water temperature is not exceeded. If necessary, install an approved safety device for this purpose. Boiler Coding Card IMPORTANT Only the boiler coding card supplied with the standard equipment of the boiler may be used. The coding card is enclosed in the accessory pack of the boiler. 1. Push boiler coding card through recess in the cover and insert it into plug-inlocation X7. IMPORTANT If the boiler coding card is not installed the following fault code will be displayed on the boiler control: b7. 21

Installation Connecting Top Part of Control Unit 1.Install the rear control housing. 2. Position top of control unit on the bottom and snap together. 3. Cut through sticker, pull out hinged support bar and pull down until the lower section snaps into place. 4. Snap the end of the hinged support bar in the hold-in clip at the bottom of the control. 5. Insert the flat cable connector into plug-in location X10 and lay cable under holding clip. 6. Unlock hinged support bar by applying pressure to linkage point and bring top of control unit down, snapping into bottom of control unit. 22

Installation Opening the Control Unit 1. Open the flip-down cover. 2. Using a suitable tool, e.g. a Viessmann hexagon socket screw key, unlock the top of the control and raise until hinged support bar snaps into place. 23

Appendix Post-Installation Checklist Please check the following conditions and correct any deficiencies: Limit capillaries and sensors correctly inserted into sensor wells? Electrical connections performed correctly? All connections properly connected? Boiler coding card inserted? Fuse F2 plugged in? Outdoor temperature sensor mounted correctly and cable connected properly to outdoor temperature sensor and plug? Fixed high limit and adjustable high limit adjusted properly (if required)? Labelled fields on programming unit according to heating circuit allocation? Start-up and adjustments See Vitotronic 200 Service Instructions Service binder 1. File Installation, Operating and Service Instructions in service binder. 2. Install a protective hanging case near the boiler and store the Service Binder in this location. Technical Data Rated voltage: 120 VAC Rated frequency: 60 Hz Rated current: 6 A Power consumption: 5 W Certification: CSA certified (in conjunction with a Viessmann boiler only) Max. ambient temperature during 32 to 104 ºF operation: 0 to 40 ºC For use in living accommodation and boiler rooms (normal ambient conditions) during storage or transport: 4 to +149 ºF 20 to +65 ºC Relay outputs of Power/Pump Module 120 VAC for heating circuit pumps 20-1 3FLA *1 20-2 DHW pump : 3 FLA *1 DHW recirculation pump : 3 FLA *1 mixing valve actuator : 0.1 FLA *1 burner connection : 2 FLA connection : 2-stage: 0.5 FLA modulating: 0.05 FLA Total: 12.5 A *1 Total max. 10 A 24

25

26

27

Technical information subject to change without notice. Printed on environmentally friendly (recycled and recyclable) paper. Viessmann Manufacturing Company (U.S.) Inc. 45 Access Road Warwick, Rhode Island 02886 USA Tel. (401) 732-0667 Fax (401) 732-0590 www.viessmann-us.com mail@viessmann-us.com 28 Viessmann Manufacturing Company Inc. 750 McMurray Road Waterloo, Ontario N2V 2G5 Canada Tel. (519) 885-6300 Fax (519) 885-0887 www.viessmann.ca mail@viessmann.ca