The recommended TMV temperature range for domestic hot water service shall be: 80 F F (27 C 49 C).

Similar documents
endless advances for your customers WATER HEATING SOLUTIONS FOR BUILDERS

Enjoy The Value Of An Amazingly Affordable ENDLESS SUPPLY OF HOT WATER. VALUE SERIES TANKLESS WATER HEATERS

Rinnai RH180 Hybrid Tank-Tankless Water Heaters

AN EASILY ATTAINABLE LUXURY.

It won t just meet your hot water needs. It will exceed them. RH180 Hybrid Tank-Tankless Water Heater

endless opportunities TANKLESS WATER HEATING SOLUTIONS FOR DEALERS AND INSTALLERS

endless quality and support

It Won t Just Meet Your Hot Water Needs IT WILL EXCEED THEM. RH180 HYBRID TANK-TANKLESS WATER HEATER

energy-efficient Hot Water Never Looked So Good

DELIVERING AN ENDLESS SUPPLY OF HOT WATER.

EXCEED THEM. COMPREHENSIVE WATER HEATING

SE and SE+ Series Tankless Water Heaters

Rinnai The Affordable Way to Heat Water. Features and Benefits of the Value Series. Rinnai Value Series The Perfect Combination of Comfort and Value

Installation & Operation Manual Models: TSU

HOMEADVANTAGE II IMPORTANT SAFETY INFORMATION

Don't Just Meet Hot Water Needs. EXCEED THEM. COMPREHENSIVE WATER HEATING

M-SERIES. endless. quality and support. The highest standards of quality. 100 years of smart comfort. rinnai.us rinnai.ca

Direct Vent Tankless Water Heater. Operation Instructions

THE NEXT GENERATION IN CONDENSING BOILERS M-SERIES

THE RINNAI LUXURY SERIES TANKLESS WATER HEATERS ENERGY-EFFICIENT HOT WATER NEVER LOOKED SO GOOD

Non-Condensing Tankless Water Heater Service Manual

We Make An Endless Supply Of Hot Water

endless opportunities TANKLESS WATER HEATING SOLUTIONS FOR DEALERS AND INSTALLERS

PRO SERIES IMPORTANT SAFETY INFORMATION

Condensing Gas Boilers SUGGESTED LIST PRICE (U.S.)

DELIVERING AN ENDLESS SUPPLY OF HOT WATER.

IT WON T JUST MEET YOUR HOT WATER NEEDS.

Caleffi Hydronic Solutions Contact: Rex Gillespie, Director of Marketing Phone: (414)

Surround Yourself With COMFORT AND WARMTH. VENT-FREE FAN CONVECTORS

Automatic Temperature Controller (ATC)

Installation & Operation Manual Models:

ENERGYSAVER Direct Vent Wall Furnaces

The comfort of consistent warmth. The confidence of superior engineering.

The Confidence Of Superior Engineering. THE COMFORT OF CONSISTENT WARMTH. ENERGYSAVER DIRECT VENT WALL FURNACES

Rinnai. Energy Presentation

THE NEXT GENERATION IN CONDENSING BOILERS

Crown Boiler Company

GOLD Plus 30/40/60/80

Make Every Room In Your Home WARM AND COMFORTABLE With Rinnai Heating Solutions.

COMMON VENTING SYSTEM SUBMITTAL SHEET

INSTALLATION INSTRUCTIONS

WATER HAMMER something that never should occur in a steam system

HEATING SOLUTIONS. endless. heating solutions HOME HEATING SOLUTIONS

521 Series. MixCal adjustable three-way thermostatic mixing valve. Installation, commissioning and service instructions

COMMON VENT SYSTEM. Features and Benefits. Model Applicability

HEATING SOLUTIONS. endless. heating solutions HOME HEATING SOLUTIONS

Tankless Rack System (TRS) Installation Manual

TURBOMAX USE & CARE MANUAL WITH INSTALLATION INSTRUCTIONS FOR THE CONTRACTOR

5231 Series. Low Lead High Flow Thermostatic Mixing Valves. Installation, commissioning and service instructions ASSE 1017 NA10341

SECTION DOMESTIC WATER PIPING SPECIALTIES

Water Heaters. energy-efficient Hot Water Never Looked So Good #1 PRODUCT FOUR CONSECUTIVE YEARS IN BUILDER MAGAZINE S FAVORITE 50

INSTALLATION INSTRUCTIONS & HOME OWNERS MANUAL ECO 18 ECO 24 ECO 27 IMPORTANT SAFETY INFORMATION

Model TWBS.SHE Tempered Water Blending System

Q - Series Boiler. Troubleshooting Manual

ERGOMAX 7 INSTALLATION

Direct Vent Tankless Water Heater Installation and Operation Manual

Installation S HL2X2 High Capacity Manifold System. Table of Contents Rev. B; ECN Bradley Page 1 of 8 11/10/2014

Installation Manual Water Tempering Manifold

Model 9201EFE Tempered Water Blending System

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual PT-30 PT-40 PT-50 PT-60 PT-80 PT-120

AHWG Remote Mount Hot Water Generator Module

Steam System Best Practices Document No. 11

Intro to Commercial Tankless Technology

Installation Manual NPE-180A/240A WARNING. Add-on Controller Installation Kit

Customer Requirements Pre-Installation Instructions

INSTALLATION MANUAL Tankless Rack System

HYDRONIC TEMPERING VALVES. Part No. High Temp F. Part No. Low Temp F

AHWG Remote Mount Hot Water Generator Module for TTP Series Outdoor Split Unit

Tankless Water Heaters SUGGESTED LIST PRICE (U.S.)

THE HEATING BOX. Training Manual. Model KD-HBO100 & KD-HBC100. * KD-HB100 (Open-Loop System) * KD-HBC100 (Close-Loop System)

TMC Temperature Monitoring Control Temperature Range -30 to 250 F (-35 to 120 C)

endless comfort and performance TANKLESS WATER HEATING SOLUTIONS FOR THE HOME

Manifold Installation Controller MIC-180. Installation and Operation Instructions

Owner Manual Pre-Heat Appliances Single Wall Heat Exchanger

2016 Plumbing Supplemental Plan Review List

Thermostatic Mixing Valves

OPERATING AND INSTALLATION MANUAL

Thermostatic mixing valves with interchangeable cartridges

Installation Manual WARNING. Add-on Controller Installation Kit NPE-180A/210A/240A

OPERATING AND INSTALLATION MANUAL

Heat Transfer Products, Inc. 120 Braley Road East Freetown, MA The first totally integrated multiple boiler management control.

DEMAND DUO 80-GALLON HYBRID WATER HEATING SYSTEM SUBMITTAL SHEET

SECTION ELECTRIC WATER HEATERS

CodeNotes. Solar Water Heating Systems Based on the 2015 International Solar Energy Provisions. Introduction. Solar Water Heating System Designs

SuperStor Ultra Stainless Steel Storage Tank

Water Heaters. energy-efficient Hot Water Never Looked So Good #1 PRODUCT FOUR CONSECUTIVE YEARS IN BUILDER MAGAZINE S FAVORITE 50

Storage Tanks. Instruction Manual. To the Installer: Please attach these instructions next to the water heater.

Partner. Peerless. Indirect-Fired. Water Heater. Installation, Operation & Maintenance Manual

Model 9201EW Tempered Water Blending System

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Installation Keltech S19361 Heater Safety Fixture Skid Keltech S19361F Freeze Protected Heater Safety Fixture Skid

Modular Panel System for Radiant Floor Heating MICRO-BOILERS MODULAR PANEL SYSTEMS

Residential Solar Water Heater

hydronics WHAT S WRONG WITH THIS SCHEMATIC?

STORAGE TANK INSTALLATION and OPERATION MANUAL

Outdoor Reset Control Theory FULL versus PARTIAL reset

Installation. Manual. Installation. Startup Maintenance Parts NOTICE WARNING

Tankless Water Heater Kits

Product Manual. Companion Water Heater. Maintenance Parts. Installation Startup. for WM97+ Gas-Fired Boilers

Transcription:

Technical Bulletin 87 Rev B- Damping Thermal Shock Events in Combined Space and Water Heating Systems General Requirements: Requirements for achieving satisfactory installation of Rinnai s Tankless Heating Systems are not more challenging than, nor distinctively different from, those requirements for a conventional hydronic heating system. This technical bulletin offers general recommendations to address thermal shock. The final requirements for any particular installation however, shall be specified by the engineer or the designer and shall adhere to methods outlined herein and to all national and/or local codes and ordinances having jurisdiction. It is required that Tankless Water Heaters being employed in combined space and water heating systems are set at a minimum 140 F (60 C) supply water temperature; this is necessary to facilitate proper tempering of the effects of ground water temperatures (particularly when operating in cold climates). Thermostatic Mixing Valve (TMV): For reasons as stated above, all systems configured for combined space and water heating applications MUST be equipped with an approved thermostatic mixing valve (TMV) designed for anti-scald, anti-chill, and thermal shock defense. The TMV should have at least the following agency approval: ASSE 1017, CSA B125.3 and UPC (IAPMO) listed. The recommended TMV temperature range for domestic hot water service shall be: 80 F - 120 F (27 C 49 C). WARNING Water temperature above 120 F (49 C) can cause serious injury. Mixing valve temperature setting should be done by licensed contractor per local code requirement. To ensure correct temperature control, use water thermometer at faucet outlet. Cause and Effect of Thermal Shock: Thermal Shock is a term used to describe the flow, and pressure altering forces, often perceived as temperature flux, in combined space and water heating systems (Combos). The underlying cause of a thermal shock event is the changing system pressure under normal operation, which is made worse by anomalies in plumbing system designs and/or incorrect Combo system installation/commissioning. From an operating standpoint, the system pressure change occurs when a valve is abruptly closed or during the start/stop sequence of the circulating pump. This in turn affects the Hot and Cold ports (of the thermostatic mixing valve) pressure differential which is specified by most manufacturers, not to exceed 10 psi. When thermal shock occurs, a high intensity pressure wave travels back through the connecting piping, from the point of valve closure/impact, until it reaches a point of relief; such as a large diameter riser. If such a relief device does not exist, the shockwave (kinetic energy accompanied by a dangerous pressure rise in the system) will then surge back and forth between the hot side of the mixing valve and the point of impact until the energy is dissipated in the piping system. The preceding kinetic energy in turn influences the modulating response of both the tankless water heater s water flow sensor and valve, and the thermostatic mixing valve s thermostat element; thus, resulting in a temperature flux at the point of domestic hot water (DHW) use. Findings from recent lab testing also indicates that plumbing anomalies (such as undersized lines and/or incorrect piping configuration) can also cause a perceived thermal shock event. TB-87 Rev B

Therefore, to mitigate said consequential temperature flux at the point of DHW use, the following steps MUST be followed as part of all combination space and water heating installation/ commissioning. Using all three of the following steps (as outlined below) will significantly damper any thermal shock event (temperature flux) generated during normal system operation. STEP 1: A hydronic mode switch has been built into all current model tankless water heaters to facilitate combo functions. This mode must be activated when units are configured for combination space and water heating applications. To activate this mode, use the follow dip switch settings chart (Table 1). Note that Dip switch settings are model series specific. TABLE 1: COMBINATION SPACE AND WATER HEATING DIP SWITCH MODE Unit Models Dip Switch Bank Dip Switch # Dip Switch Position N O N C O N D E N S I N G S E R I E S RV53e (REU-VAM1620W-US) V53e (REU-VAM1620W-US) #1 ON V94i (REU-VC2837FFU-US) V94Xi (REU-VC2737FFU-US) V94e (REU-VC2837W-US) DIPSW-1 (Yellow/Tan) V75i (REU-VC2528FFU-US) V75e (REU-VC2528W-US) V65i (REU-VC2025FFU-US) V65e (REU-VC2025W-US) #7 ON RL94i (REU-VC2837FFUD) RLX94i (REU-VC2737FFUD-US) RL94e (REU-VC2837WD-US) RL75i (REU-VC2528FFUD-US) RL75e (REU-VC2528WD-US) C O N D E N S I N G S E R I E S C199i (REU-KBD3237FFUDC-US) RUC98i (REU-KBD3237FFUD-US) RUC90i (REU-KBD2934FFUD-US) RUC80i (REU-KBD2530FFUD-US) RUR98i (REU-KBP3237FFUD-US RUCS75i (REU-KCM2528FFU-US) RUCS65i (REU-KCM2025FFU-US) RU98i (REU-KB3237FFUD-US) RU80i (REU-KB2530FFUD-US) C199e (REU-KB3237WDC-US) RU98e (REU-KB3237WD-US) RU90e (REU-KB2934WD-US) RU80e (REU-KB2530WD-US) RUR98e (REU-KBP3237DW-US) RUS75e (REU-KCM2528W-US) RUS65e (REU-KCM2025W-US) DIPSW-1 (Yellow/Tan) #7 ON 2 TB-87 Rev B

STEP 2: Refer to attached piping configuration drawings. The hydronic furnace return water line is to be hydraulically separated from the incoming ground water and the cold side of the thermostatic mixing valve. This step is necessary to prevent flow in the hydronic circuit from interfering with flow in the domestic cold water circuit. The use of a check valve (by others) in the position shown, will achieve the required hydraulic separation between the two circuits in question. STEP 3: The third and final required step is to employ one of the following devices (Thermal Shock Damping Manifold or Water Hammer Arrester) in accordance with the specifications on the attached drawings. Piping Configuration: Refer to Drawing SK-1: Thermal Shock Damping Manifold (TSDM) Drawing SK-1 illustrates the first of two alternative methods to be used in Step 3. In this particular method a manifold (refer to detail No. 1 on drawing SK-1) is used and is placed downstream of the mixing valve (tempered water out) in the main domestic hot water supply line. The manifold is to be positioned vertically with the tempered water entering at the lowest port and exiting at the highest port. The manifold is to be a minimum twelve inches (12 ) in length with a diameter greater than or equal to twice the main hot water line size. The Thermal Shock Damping Manifold (TSDM) must be field fabricated using appropriate piping material approved for potable water. The Thermal Shock Damping Manifold (TSDM) should be insulated with minimum R-4 piping insulation to minimize heat loss to the surrounding environment. Refer to Drawing SK-2: Water Hammer Arrester Drawing SK-2 illustrates the second alternate method. In this particular method a typical (off-the-shelf) water hammer arrester (refer to detail No. 2 on drawing SK-2) is used and is placed upstream of the mixing valve on the hot side. Specifically, water hammer arrester is to be located a minimum six inches below the hydronic furnace hot water supply connecting tee off the main hot water supply line but before the thermostatic mixing valve on the hot side. The Water Hammer Arrester to be sized in accordance to the respective manufacturer s sizing guidelines. Rinnai America Corporation 103 International Drive, Peachtree City, GA 30269 Toll-Free: 1-800-621-9419 Phone: 678-829-1700 www.rinnai.us 2015 Rinnai America Corporation. Rinnai America Corporation continually updates materials, and as such, content is subject to change without notice. Local, state, provincial, federal and national fuel gas codes must be adhered to prior to and upon installation. 3 TB-87 Rev B

Check Valve Required

Check Valve Required