owner s manual & parts list

Similar documents
12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

WIDE AREA VACUUM MODEL PF2030 WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

Operator s Manual. Commercial Dryer/Air Mover. Standard Models PD350, PD500, PD750. A Tacony Company

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

PROFESSIONAL AIR MOVER OWNER S MANUAL

ATD PEDESTAL FAN INSTRUCTIONS

BEFORE OPERATING THE MACHINE: WARNING

Commercial Dryer/Air Mover

OPERATIONS MANUAL & PARTS LIST. BX2 Fastracts Extractor. IPC Eagle 3650 Dodd Rd, Eagan MN

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

Owner s Manual READ AND SAVE THESE INSTRUCTIONS

OmniDry 2.9 Amp Centrifugal Air Mover

MAXUM 5 5 Gallon Box Extractor

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

Model PF 2030 Wide Area Vacuum Cleaner

Phoenix AirMAX - Radial Air Mover

UB20 12V DC. Owner s Manual

Summer Breeze Heater Service Manual

ATD BELT DRIVE DRUM FAN INSTRUCTIONS

Aqua Dri AIR MOVER / CARPET DRIER SAFETY, OPERATION & MAINTENANCE INSTRUCTIONS

Commercial Spotter Model number PS35

LOW PROFILE AIR MOVER

2 SPEED PUMP INSTRUCTION MANUAL READ THIS MANUAL CAREFULLY BEFORE USING YOUR 2 SPEED PUMP

Workman 3, 6, & 10-Gallon Wet/Dry Vacuums. Technical Information & Safety Page 3, 4

Workman 3, 6, & 10-Gallon Wet/Dry Vacuums. Technical Information & Safety Page 3, 4

Sanitaire. Owner s Guide. 10 GALLON Box Extractor SC6088 Series IMPORTANT

AURA WIDE AREA VACUUM Parts Manual

Operating Instructions (ENG) MODEL: 115 V UL LISTING FOR 1/2 HP MODELS ONLY. Read instructions before operating the machine J 07/05/07

PACER 30 VACUUM IMPORTANT SAFETY INSTRUCTIONS READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE OPERATING OR SERVICING MACHINE

30 Professional Cooling Unit. Model Number: XC3000. Owner s Manual READ AND SAVE THESE INSTRUCTIONS

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

GALE FORCE VAF-16R. Ventilation Manual

OPERATIONS MANUAL REV A

#8 STAINLESS STEEL ELECTRIC MEAT GRINDER OWNER S MANUAL

LARGE AREA VACUUM LAV-30

8 lb Lightweight Vacuum Model CK LW 13/1

MC MC MC MC MC833130

16 OUTDOOR MISTING FAN

CV100T Dry Canister Vacuum. Technical Information & Safety Page 3, 4

GALAXY 5 Owner s Manual & Parts List

Viking Installation Guide

Owner s Manual & Safety Instructions

WAV-30 WIDE AREA VACUUM

WAILEA OWNER S MANUAL

P-200T / P-200AT / P-230AT (115V / 60Hz)

IMPORTANT SAFETY RULES

SSS Speedster 600 (Model SP-600, #56001) SSS Speedster 1000 OPERATION SERVICE PARTS CARE. SSS Speedster 1000 SSS Speedster 600

OWNER S MANUAL. Model No. B-16 STAND PET DRYER

Operator Manual - Workman Wet/Dry Vacuums IMPORTANT SAFETY INSTRUCTIONS

D14 & D18 Upright Vacuum

MODEL # PUMA G, 3-SPEED TRANSPORTABLE AIR MOVER

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

Canister Vacuums S6EVO. Operations and Parts Manual. Models: S6EVO

Operating Instructions (ENG) MODEL: AM115V. Read instructions before operating the machine. AM /24/00

Flood Pumper Plus. Water Transfer Machine. Operator and Parts Manual. Model No.: Rev. 00 (11-99)

690 Power Fishing System

IMPORTANT INSTRUCTIONS

238 Series. Industrial/Commercial Electric Unit Heater. Owner s Manual

MAXUM Gallon Box Extractor

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 183A FILE NO. SA 183A REFERENCE NO. SM Destination Australia SA-183A

Safety, Operation and Maintenance Manual with Parts List

FIBERPRO SPOTTER CARPET. 3.5 Gallon Carpet Spotter Machine. Operator and Parts Manual E

690 and Power Fishing Systems

20-GALLON MOBILE PARTS WASHER OWNER S MANUAL

3.5-GALLON PARTS WASHER OWNER S MANUAL

ANYWHERE. U.S. Patent(s) Pending INSTRUCTION MANUAL WARRANTY CERTIFICATE

CRV Clean Room Vacuum

1 HP Air Mover. Owner s Manual

Owner s Manual CMC100 Dehumidifier

COBRA -H EXTRACTOR 120V

Electronic Service Manuals

Gallery Electric Fireplaces

HOTSPOT. Two Gallon Pump Up Spotter OPERATING & MAINTENANCE

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

WAV-26 UPRIGHT WIDE AREA VACUUM

JOB EXTRACTOR OPERATIONS MANUAL REV A

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 123A FILE NO. SA 123A REFERENCE NO. SM700513

SAFETY, OPERATION AND MAINTENANCE MANUAL. DRY VACUUM CLEANER This unit is intended for commercial use. SAVE THESE INSTRUCTIONS

Operations and Parts Manual

π H-6621 INDUSTRIAL DEHUMIDIFIER WARNINGS SPECIFICATIONS uline.com WATER REMOVAL ELECTRICAL REQUIREMENTS BUILT-IN ELECTRICAL SAFETY

TIDALWAVE I/G POOL PUMP INSTRUCTION MANUAL

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

BIOCIDE ANTIMICROBIAL DRY VACUUM

SOUTHERN ENTERPRISES INC.

17" PRO BUFFERS. Operation l Care l Service. Caution! Read Safety and General Instructions carefully before using for the first time. REV.

MAXI PUMP INSTRUCTION MANUAL NE6151B /NE6171B READ THIS MANUAL CAREFULLY BEFORE USING YOUR MAXI PUMP

ATD Gallon Parts Washer Owner s Manual

E700 WIDE AREA VACUUM

Installation Instructions and Homeowner's Manual

SPOTTER CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL

ITEM NO. FA532300TX ELECTRIC FIREBOX INSERT OPERATION MANUAL

PILEJOGGER II MODELS: PJ2A PJ2AIE Operating Instructions (ENG) Read instructions before operating the machine.

Owner s Manual CMC100 Dehumidifier

POLISHERS. MODELS SeaRay 133 OPERATING & MAINTENANCE

Ceramic heater FAN. Distributed exclusively by Harbor Freight Tools Mission Oaks Blvd., Camarillo, CA 93011

EdenPURE Bladeless Tower Fan/Heater Instruction Manual

READ AND SAVE THESE INSTRUCTIONS

PUREPOWER SERIES CENTRAL VACUUM POWER UNITS PP500, PP600 & PP650

BIG BEAR VORTEX FAN MODEL #BB-2

Transcription:

AVIATOR owner s manual & parts list This equipment is intended for commercial use only. 3009AF 3009AF-W 1753 Blake Avenue Los Angeles, CA 90031 (800) 338-EDIC Or (323) 660-1635 Fax (323) 667-0144

BEFORE OPERATING THE MACHINE Read the manual carefully and completely before attempting to operate the unit. This manual has important information for the use and safe operation of the machine. Keep this manual handy at all times. This machine will assure years of satisfactory service if operated and maintained according to recommendations in this manual. If additional information is needed, please contact your local distributor or write to: EDIC 1753 Blake Avenue Los Angeles, CA 90031-1006 Electrical 115 Volt This machine is designed to operate on a standard 15 amp., 115 volt, 60 Hz, AC circuit. Voltages below 105 volts AC or above 125 volts AC could cause serious damage to the motor. Electrical 240 Volt This machine is designed to operate on a standard 10 amp., 230 volt, 50 Hz, AC circuit. IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS BEFORE USING DANGER Improper connection of the equipment s grounding conductor can result in a risk of fire, electric shock or injury to person. Check with a qualified electrician or service person if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the air mover if it will not fit the outlet. Have a proper outlet installed by a qualified electrician. WARNING This equipment is not designed to handle or use combustible/volatile substances such as gasoline or kerosene, in, on, or near the machine. The use of such materials will cause an extreme hazardous condition. Do not immerse or use this machine in standing water. Such use may cause electric shock. Disconnect the power cord from the outlet before servicing. Ensure that children do not have access to the equipment. Do not allow children to play with or near the unit or in its air flow. Do not use with damaged cord or plug. If air mover is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return it to an authorized service center. Repairs are only allowed by a qualified service center. Do not attempt to disassemble or repair the unit if you are not qualified to do so. For information about authorized repair, call EDIC at (800) 338 3342.

When using an extension cord, use only a 3-prong conductor grounding cord 12 ga. wire or heavier. Check GFCI protection before each use by pushing the test button. If operating properly the reset button will pop out. Never operate with the safety grills removed. Personal injury may result. Do not plug more than 9.0 amps total into the GFCI outlet. To avoid electric shock, do not expose the unit to rain. Store it indoors only. Do not expose machine to freezing temperatures. Do not move or carry the unit when it is turned on. Do not pull or carry by the cord, use cord as a handle, close a door on the cord, or pull cord around sharp edges or corners. Keep cord away from heated surfaces. Do not unplug by pulling on cord. To unplug the unit, grasp the plug, not the cord. Do not handle plug or air mover with wet hands. Do not put object into openings. Do not use with any opening blocked; keep free of dust, lint, hair and anything that may reduce air flow. Keep hair, loose clothing, fingers and all parts of the body away from openings and moving parts. Turn off all controls before unplugging. Connect to a properly grounded outlet only. See grounding instructions. Operate unit on level and stable surface to prevent it from falling and possibly causing injury. Do not drop or throw the unit. Treatment of this type can cause damage to the components and create a hazardous condition. To reduce the risk of fire or electric shock, do not use this air mover with any solid-state speed control devices. FAILURE TO COMPLY WITH THE ABOVE WARNING INSTRUCTION WILL VOID THE WARRANTY. GROUNDING INSTRUCTIONS: The 120 V. A/C and the 220 V. A/C models have been outfitted with the appropriate grounded connectors. Make sure the machine is connected to a grounded outlet having the same configuration as the grounded plug. No adaptor should be used with this machine. Any modification to the connectors will void the warranty.

INTENDED USE: The Aviator is designed to blow air across wet surfaces for speed drying. The high-volume airflow from the Aviator increases the rate of evaporation, helps prevent mold growth, and reduces the risk of additional moisture damage. POSITION SWITCH: The 3-position drying mode selector switch is used to select the Aviator s mode of operation. The 3 modes of operation are OFF, LOW or HIGH. GFCI Protection and the OnBoard Duplex Vac Outlet: The standard AC voltage outlet GFCI (Ground Fault Circuit Interrupter) protection promotes operator safety in wet applications. GFCI devices trip when a fault to electrical ground is sensed. It is recommended to check the GFCI protection prior to operation. To check, push the TEST button located of the GFCI duplex outlet. If operating properly, the RESET button on the GFCI will pop out. This duplex AC outlet allows the Interconnection of the other AC powered devices. The sum total amperage of all devices plugged into the receptacle must not exceed 9 amps. DAISY CHAINING: The Aviator draws 2.3 amps. The 12 amp onboard circuit breaker will allow four (4) Aviators on one circuit. Five (5) is too many for one circuit. When daisy chaining the Aviator, turn on one Aviator at a time to prevent excessive current inrush caused by four units starting at once. A ground fault in the Aviator or anywhere on the circuit will cause the Aviator s GFCI to trip. After rectifying the ground fault, reset the GFCI by pressing the reset button. OPERATING PROCEDURES: Plug the Aviator into a standard grounded outlet with correct voltage and amperage. Turn on the switch and check that the unit operates properly before leaving it unattended. Do not carry or move the Aviator when it is running. MAINTENANCE: 1. Disconnect the power cord from the outlet before performing this maintenance procedure. 2. Inspect the electrical cord and wiring for damage or discoloration. 3. Inspect for loose fasteners. 4. Clean screens on the side and front of the unit. 5. Listen for abnormal sounds. 6. Keep unit clean. 7. Motor does not require lubrication.

PERIODIC MAINTENANCE: Use compressed air or a vacuum to remove lint, etc, from the motor, screen or blower. Do not wet the motor or the wiring. Do not use a pressure washer to clean the unit. TROUBLESHOOTING MOTOR WON T RUN No power to unit Switch not turned on Switch is defective Defective power cord Capacitor is defective Fan blade jammed Intake or exhaust grill blocked Loose wiring Plug in the unit; check circuit breaker or fuse. Turn on the switch. Call you local distributor for a replacement. Turn machine off, remove material jamming blade. Turn machine off, allow to cool, remove blockage. Check wiring and tighten as needed. MOTOR RUNS BUT BLADE SCRAPES Severe jolt has caused motor mount to bend and fan blade to rub Remove motor from housing, then replace or repair bent motor mount. UNIT VIBRATES EXCESSIVELY Accumulation of soil on fan blade Fan blade has lost balance Fan blade has been bent Bent motor shaft Clean fan blade. Balance or replace fan blade. Replace fan blade. Replace motor. DOES NOT OPERATE AT ALL SPEEDS Switch is defective Capacitor is defective UNIT MAKES ABNORMAL SOUNDS Defective motor Foreign object stuck Remove material jamming blade.

1 2 3 4 5 6 7 8 9 10 11 15 12 13 14 19 18 17 16 20 21 27 22 28 29 30 23 24 25 26 31 41 40 39 38 37 36 35 34 33 32 3009AF-W 7-7-08

3009AF-W ITEM # PART # DESCRIPTION QTY 1. F-12111-1 Green Housing - Axial Fan 1 2. F00463-2 Corrugated Loom,.25 x 6 in 1 3. B13095 Bullet splice, 16-10 AWG 2 4. B00185-40 Wire, 14GA Black, UL1015, 25 in 1 5. B00185-30 Wire, 14GA White, UL1015, 015,18 in 1 6. B00190 Nylon Tie, 4 in 3 7. C13122 10-24 X.375 SHCS, SS 8 8. D12133 Bracket, Motor Mount, Fan 4 9. C13025 Hex Nut, 10-32 W-Star 8 10. D12112 Grille, Axial Fan 2 11 C13093 #8 X.75 Phil, Flat 6 12 G12117 Motor, Axial Fan, 110V 1 13 B02214 Strain Relief Nut, (O) 1 14 C00310-38 Screw, 8-32 X.375 RH Mach 2 15 B00180-10-3 Ring Terminal, #10 Center 1 16 B11720 Flag Connector (Yellow) 1 17 B10980 Flag Connector (Blue) 7 18 B02212 Strain Relief W-Nut, (O) 1 19 H11831 Label, EDIC, Black-Silver 1 20 C13090 #6 X.375 Phil Pan 6 21 B12120 Circuit Breaker, 12 AMP 1 22 D13049 Switch Plate, Axial Fan 1 23 G12129 Fan, Axial, 40 Degree 1 24 C13119 Hex Nut, 6-32 KEP 2 25 B12976 Hour Meter, 110-220V 1 26 C13118 6-32 X.375 Phil 2 27 B12914 Ground Fault Interrupter 1 28 C13120 Hex Nut, 8-32 KEP 2 29 B11751 Switch, Rocker, DPDT, Black 1 30 B11756 Indicator Light, Green 1 31 H02548-2 Label, Important 1 32 B10719 Power Cord, 25, 16-3 1 33 B11821 Strain Relief, Aqua Dri 1 34 B11832 Strain Relief Nut 1 35 H13031 Label, Electric Shock 1 36 H03545 Cover, Serial # Label 1 37 H00565-5 Label, Serial Number 1 38 K13076 Bumper, Foot, WSteel 8 39 C13092 10-24 X.75 Phil Pan Head 8 40 G13075 Socket for Swivel Caster 3 41 G13074 Caster, Swivel, 3 X.187 in 3

1753 Blake Avenue Los Angeles, CA 90031 (800) 338-EDIC Or (323) 660-1635 Fax (323) 667-0144 ZF13167