EBAC MODEL GENESIS AVENGER APOLLO AIR MOVER OWNER S MANUAL

Similar documents
EBAC MODEL AD850 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD30 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL K100 DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD60 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL KOMPACT INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL BD-150 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD425 ( ) INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

DD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CD30 / CD30E DEHUMIDIFIER (FULL PRODUCT RANGE) OWNER S MANUAL

EBAC MODEL WM150 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

RM85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

FREE STAR INDUSTRIAL DEHUMIDIFIER USERS MANUAL

BD80 / BD80-XE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

NEPTUNE INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

12 VELOCITY OWNER S MANUAL OPERATING INSTRUCTIONS - MAINTENANCE - SAFETY - TROUBLESHOOTING

CS90H INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

PROFESSIONAL AIR MOVER OWNER S MANUAL

EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

EBAC MODEL CD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

CS90E INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

owner s manual & parts list

EBAC MODEL PD200 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

K100P DEHUMIDIFIER OWNER S MANUAL

LOW PROFILE AIR MOVER

ECO85 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

Phoenix AirMAX - Radial Air Mover

The POWER. In PRESENTATION PRODUCTS. Instruction Book For Professional Electrol DA-LITE SCREEN COMPANY, INC.

CD35 / CD35P INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL

GENESIS Air Conditioners. All Models INSTRUCTION MANUAL nvent Rev. K P/N

OWNER S MANUAL MULTIPURPOSE UTILITY AIR MOVER PLEASE READ AND SAVE THESE INSTRUCTIONS X-400WFK (WITH FILTER KIT) ITEM NO:

Spiral Dough Mixer. Instruction manual. Model: CP821

PAC series Portable Air-Cooled Spot Cooler

HYBRID DRYER. PDH1 - PDH2 Series. Save These Instructions

T-Series Air Conditioner T20 Model

AH-470. Flat Panel Micathermic Space Heater OWNERS MANUAL. Read and save these instructions.

e Bath Fan with Light User s Guide

OWNER S MANUAL #DC2000B #DC2000BCF

T-SERIES Air Conditioner. T50 Model INSTRUCTION MANUAL nvent Rev. F P/N

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES C

SPECTRACOOL Air Conditioner. N21 Model INSTRUCTION MANUAL nvent Rev. G P/N

DR-180 Through the Wall Exhaust Fan PRODUCT MANUAL & INSTALLATION GUIDE

T-SERIES Air Conditioner. T20 Model INSTRUCTION MANUAL nvent Rev. C P/N

READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AN

T-Series Air Conditioner T53 Model

RV Products Division INSTALLATION INSTRUCTIONS FOR SERIES PACKAGE AIR CONDITIONER

Gen-Air Air Mover. Gen-Air Air Mover. Safety, Operation and Maintenance Manual with Parts List Please read before use! 1/2 HP, 3-Speed Motor

Revised: Copyright Bridgepoint Systems, Inc

Owner s Manual. Portable Air Conditioner ARP-5008 ARP Royal Sovereign International, Inc.

HYBRID DRYER. PDH1 - PDH2 Series WARNING: OPERATOR MUST READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THIS EQUIPMENT.

T-SERIES Air Conditioner. T43 Model INSTRUCTION MANUAL nvent Rev. I P/N

V-SERIES Air Conditioner. VA08 Model INSTRUCTION MANUAL nvent Rev. F P/N

STEAM WALLPAPER STRIPPER MODEL HTW5

HEA USER MANUAL. 1 Version: 22. June 2010

REDRING POWERSTREAM UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

IMPORTANT INSTRUCTIONS - OPERATING MANUAL

PROAIR Air Conditioner. CR29 Model INSTRUCTION MANUAL nvent Rev. I P/N

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

OWNER S MANUAL #DC2000Y #DC2000YCF 2 HP, 1500 CFM DUST COLLECTOR. VERSION 1 -w/ 6 INLET PORT. Model #DC2000Y Global Rd.

Display Chiller. Instruction manual. Model Modèle Modell Modello Modelo Malli: CB507/CB509/G619/G211/DP288/DP289/ CG582. Gekoelde Vitrine Handleiding

PROAIR Air Conditioner. CR23 Model INSTRUCTION MANUAL nvent Rev. D P/N

Models A710 and A710S Grills. TOASTMASTER Models A710 and A710S Grills

BF5000NT BF5000 EF2604 SF2603 DF2603

Operation Manual SCT14B and SCT18B. Inspection. 3 General Description. 3 General Requirements. 3 Standard Features.

Model No: Little Devil II (inc ss)

Installation Instructions and Homeowner's Manual

Instruction Manual. Window AC 12000BTU. Energy- Saving Mode. Wards.com MODEL: 12000BTU Item No.: V~, 60Hz, 1060W

e Bath Fan with Light User s Guide

SELF-CONTAINED POWER MISTER

W Model 1RKU2 w/optional Wall mount. Unit Model Weight (Lbs) Kilowatts Volts- Phase Amps Fan Output Heat Output

Saturn Booster PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE AND KEEP THEM FOR FUTURE REFERENCE

Product instruction manual Easymount Wide Format Laminators

INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS

1 HP Air Mover. Owner s Manual

Operating Instructions & Parts Manual. Silent Low-Profile Ceiling Fans. Models 3DPE2A, 3DPE3A, 1UBH6B, 1UBH7B, 1UBH8A, 5AE68B, 5AE69A

The Da-Lite Difference.

INSTALLATION AND OPERATION INSTRUCTIONS FOR BI-DEEP UNITS

INSTALLATION AND OPERATION INSTRUCTIONS FOR SAFETY INFORMATION WARNING

Installation. 324 Series Built-In Dishwashers U L. Viking Range, LLC 111 Front Street Greenwood, Mississippi USA (662)

e Bath Fan with Light User s Guide

50L/D DEHUMIDIFIER. Model Number: IG9805 INSTRUCTIONS FOR USE

AquaReef Cube. Inspiring Excellence in Fish Keeping!

Summer Breeze Heater Service Manual

W-Series Portable Water-Cooled Spot Cooler

T-SERIES Air Conditioner. T29 Model INSTRUCTION MANUAL nvent Rev. I P/N

1. SAFETY RULES WARNING WARNING. 8. Avoid placing objects in the path of the blades.

18E ELECTRIC FAN HEATER

PROAIR Air Conditioner. CR43 Model INSTRUCTION MANUAL nvent Rev. H P/N

e Heater/Exhaust Fan/Light User s Guide

Operation and Maintenance Manual BLIZZARD50 CS6-50-VD 120V/60HZ

INSTALLATION AND OPERATION INSTRUCTIONS FOR

DRY 150 Quest PowerDry 1300

Transcription:

EBAC MODEL GENESIS AVENGER APOLLO AIR MOVER OWNER S MANUAL Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website www.ebacusa.com

UNPACKING Remove the top insert and your Ebac Air Mover from its packing carton, then visually inspect for any signs of transit damage. If there are any signs of damage, do not operate your unit. Call your supplier immediately for advice. Do not discard the packing for it will be useful for transporting your unit in the future. TRANSPORTATION A cord wrapping facility has been moulded into the plastic fan housing. The power cord should be wrapped around this facility during transit. Do not drop or abuse your airmover during transit for risk of damage to both the motor and housing. INTRODUCTION Ebac Air Movers are high performance, high efficiency fan systems designed to optimize air movement and minimize operating costs for drying applications. With various features and capabilities to accommodate your drying needs, The Ebac Air Mover Series consists of 3 models: GENESIS: 1/3 HP (SINGLE SPEED) AVENGER: 1/3 HP (THREE SPEED) APOLLO: 1/2 HP (THREE SPEED) Each model incorporates a double inlet, centrifugal type fan design to provide the high static pressure and airflow required to dry water damaged facilities and equipment. The Ebac Air Mover series was designed to provide you the best performance and serviceability. 25 ft. Power Cord with Moulded Cord grip Internal Thermal Circuit Breaker Aerodynamic, Rotationally Moulded Polythelne Housing. High Efficient 1/3 & 1/2 HP Motors Single & Three Speed Fan Designs 4 operating Positions (0º, 12º, 45º, & 90º) Optional Carpet Clamp Stack ability in the Vertical Plane during both Storage and Operation. Moulded Cord wrap Facility

OPERATING PROCEDURES Connect the power cord into a 15 amp grounded electrical outlet, turn the power switch to the ON position. If you have no power or hear and loud or abnormal noises, refer to the Troubleshooting part and consult the Factory Service Center. Your Ebac Air Mover is designed to operate in 4 positions to allow drying of floors, walls and ceilings. Your Ebac Air Mover comes with internal circuit protection for your safety. When working around a wet environment, we also recommend always plugging the unit into a ground fault interrupter to assure the best protection. For the drying of water damaged facilities, we recommend using an Ebac dehumidifier along with your air mover to provide you with more efficient drying. Your air mover is designed to induce evaporation or water contained within flooded surfaces or materials. Yet, without a mechanism of removing the moisture from the air, drying will not occur. It is recommended that the dehumidifier outlet is close to the air mover intake. This allows for dry air to be distributed by the air mover. WIRING: Connect the power mains cable/plug of the dehumidifier unit to a 16 Amp power supply. As follows:- Brown Blue Green/Yellow Live Neutral Earth (ground)

SPECIFICATIONS MODEL: GENESIS AVENGER APOLLO PART NUMBER: 1890100 1890200 1890300 HEIGHT: 21 21 21 WIDTH: 20 20 20 DEPTH: 19 19 19 WEIGHT: 31 lbs 32 lbs 34 lbs HORSEPOWER 1/3 1/3 1/2 POWER SUPPLY: 115V/60Hz/1ph 115V/60Hz/1ph 115V/60Hz/1ph AMPERAGE: 4.2 3.8 6.0 SPEEDS: 1 3 3

REPAIRS Your air mover was designed to minimize the amount of maintenance/repairs required by utilizing a maintenance-free motor. However, to assure the longest product life, follow the maintenance procedures listed below as often as necessary. TROUBLESHOOTING SYMPTOM Unit Inoperative/Airflow Excessive Vibration/Noise CAUSE 1. No power to unit 2. Internal circuit breaker tripped 3. Loose electrical wiring 4. Fan motor burnt out 1. Loose motor 2. Loose blower wheel 3. Damaged blower wheel REMEDY 1. Check power from main supply. Reset circuit breaker or replace fuse 2. Press internal breaker on control panel to reset circuit 3. Check wiring diagram and repair fault 4. Replace fan motor 1. Tighten motor mounting lugs 2. Balance rotor and tighten set screw with allen wrench 3. Replace blower wheel Ebac Industrial Products 704 Middle Ground Boulevard Newport News VA 23606 Telephone (757) 873-6800 FAX (757) 873-3632 Website www.ebacusa.com

GENESIS, AVENGER & APOLLO SPARE PARTS LIST PART NUMBERS DESCRIPTION QTY GENESIS AVENGER APOLLO Housing 1 2894500 2894500 2894500 Rubber Foot 4 2094501 2094501 2094501 1/3 HP (1SPD) 384110 N/A N/A Motor 1/3 HP (3SPD) 1 N/A 3841101 N/A 1/2 HP (3SPD) N/A N/A 3841102 Rotor Wheel 1 3840401 3840401 3840401 Inlet Mesh (Rotor Side) 1 2094503 2094503 2094503 Inlet Mesh (Motor Side) 1 2094504 2094504 2094504 Edging Strip (.76m) 1 3032999 3032999 3032999 Cable Gland 1 3032510 3032510 3032510 Power Cord 1 3831218 3831218 3831218 Kickdown Support 1 2094502 2094502 2094502 Kickdown Sheath 2 2094506 2094506 2094506 Outlet Grille 1 2094507 2094507 2094507 Inlet Ring 1 2094509 2094509 2094509 Controls Recess 1 2094508 2094508 2094508 Grommet 1 3832107 3832107 3832107 P-Clip 1 3832414 3832414 3832414 Machine Label 1 3870509 3870510 3870511 Control Panel 1 2094510 2094510 2094510 Control 1 SPD 3870512 N/A N/A 1 Label 3 SPD N/A 3870513 3870513 Circuit 7 AMP 3832902 3832902 N/A 1 Breaker 10 AMP N/A N/A 3832903 Switch Rocker 3035914 N/A N/A 1 Rotary N/A 3036751 3036751