AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0 CAUTION

Similar documents
Bottom Mount Refrigerator---Technical Information

JBL2088HES JBL2088HES0, JBR2088HES JBR2088HES0, JFC2089HEP JFC2089HEP0, JFC2089HES JFC2089HES0, JFC2089HPF JFC2089HPF0, JFC2089HPY JFC2089HPY0

CAUTION. No-Load Performance, Controls in Normal Position

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10%

Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator.

Bottom Mount Refrigerator Technical Information

CAUTION. No-Load Performance, Controls in Normal Position. Percent Run Time ±10% Temperature Relationship Test Chart.

FOR SERVICE TECHNICIAN S USE ONLY

FOR SERVICE TECHNICIAN S USE ONLY

CAUTION. All safety information must be followed as provided in Service Manual RS ! WARNING

ARS2304A PARS2304AB0 ARS2604A PARS2604AB0 ARS2304A PARS2304AC0 ARS2604A PARS2604AC0 ARS2304A PARS2304AW0 ARS2604A PARS2604AW0 !

FOR SERVICE TECHNICIAN S USE ONLY

Image Key Part Number Description Substitution Qty.

FOR SERVICE TECHNICIAN S USE ONLY

Image Key Part Number Description Substitution Qty.

SERVICE NOTEBOOK BUILT-IN REFRIGERATOR VCSB481 / VCSB482

Fast Track Troubleshooting

Fast Track Troubleshooting

Fast Track Troubleshooting

Fast Track Troubleshooting

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

Side-by-side combined refrigerator-freezer

T-32-TS Touchscreen Thermostat. Installation Manual

Fast Track Troubleshooting

Fast Track Troubleshooting

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

Model Number Nomemclature... 1 Specifications... 3 Refrigeration System... 4 Freezer and Refrigerator Air Circulation... 5 Display Designs...

Fast Track Troubleshooting

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to range before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing.

3. OPERATING INSTRUCTIONS & INSTALLATION

Technical Information- Dishwasher MDB8750AWB MDB8750AWQ MDB8750AWS MDB8750AWW MDB9750AWB MDB9750AWQ MDB9750AWS MDB9750AWW

INSTALLATION and OPERATING. INSTRUCTIONS for. SMZP26 Series. elf-contained Freezers

Fast Track Troubleshooting

2010 Whirlpool 26 SXS Refrigerators

CAUTION. To avoid risk of electrical shock, personal injury, or death, disconnect power to dishwasher before servicing. MDBTT50AW*

Smart Temp. ApolloP/n Installation Manual. Version 1.0

Ice Maker (Fresh Food Compartment)

Product Information and Technical Guide

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.

SERVICE MANUAL MUY-GL24NA - U1. No. OBH733. Models HFC. Revision B: REVISED EDITION-B R410A

JDB4000AWB JDB4000AWQ JDB4000AWS JDB4000AWW MDB5600AWB MDB5600AWQ MDB5600AWS MDB5600AWW

Comfort System T-21-P Touchscreen Thermostat Installation Manual

2008 DOUBLE DRAWER UNDER COUNTER REFRIGERATOR / FREEZER PRODUCTS

IMPORTANT. HOSHIZAKI provides this manual primarily to assist qualified service technicians in the service and maintenance of the icemaker.

URS-1 SERVICE AND PARTS MANUAL SERIAL NUMBERS: UP TO

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

SERVICE MANUAL. No. OBH747 REVISED EDITION-A. Models HFC

Installation Instructions

Service Manual. Commercial Series Refrigerated Kitchen Equipment Models Upright S-Series. hoshizakiamerica.com

Product Information and Technical Guide

Liebert InteleCool Warranty Inspection Check Sheet

INSTALLATION/OPERATING INSTRUCTIONS BCP-3. Hot Water Reset Control For up to 3 Boilers. How the BCP-3 operates... 1:4 1:3 1:2 1:1.

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

Prodigy Flaked and Nugget Ice Machines Technical Review

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool Remote Condensing units & Cold plates.

SERVICE MANUAL OUTDOOR UNIT MUZ-FH06NAH MUZ-FH09NAH MUZ-FH06NA MUZ-FH09NA MUZ-FH09NA - 1 MUZ-FH09NAH - 1 MUZ-FH12NA MUZ-FH12NAH

Hoshizaki America, Inc.

INSTALLATION AND TROUBLE SHOOTING MANUAL for all Models of Nova Kool AC/DC and DC only Refrigerators and Freezers.

Service Documentation

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

User Guide ems25plus. Page 1. Normal operation. Product interface

Electrical Problems. Fuse(s) blow or circuit breaker trips. Does the unit use circuit breakers or fuses? Replace with correct fuse(s)

KM-630MAH KM-630MWH KM-630MRH

Application and Installation Bulletin for Master-Bilt Refrigeration Superheat Controller Kit Assembly(A ), 120/208/240/1/60, R404A, LT/MT APPS

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

4. ALIGNMENT AND ADJUSTMENTS

REACH-IN SAFETEMP (-AAC)

Liebert Fin/Tube Condenser Warranty Inspection Check Sheet

MODEL URS-1: FACTORY RETROFIT PROGRAM

Product Information and Technical Guide

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires power.

QD-ENG-68 Controller for Thermoelectric Thermal Management

AE R1 October to 5 Ton ZPS*K6 Copeland Scroll Two-Stage Compressors

Refrigerated air dryers

SERVICE MANUAL MATRIX 18.2 CU FT TOP MOUNT REFRIGERATOR

INSTRUCTION MANUAL Portable Refrigerator Units MODEL 15-LITER Including the Standard Battery Backup System (BBS)

T170 Thermostat. Installation and Maintenance Manual. 24 VAC/ VAC 3-Speed Fan Control (Continuous or Cycling) or Staged Fan Control

Service Information. WNes 2956 appliance documentation. Service Information no. 27/2004 LHG/TKD-Fe/June SI

Super-Flo Low Profile Unit Cooler

Instruction Sheet

TECHNICAL SERVICE GUIDE

1F Non-Programmable Electronic Digital Multi-Stage Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

MANUAL. Instructions for installation use & general maintenance of your HORIZONTAL FREEZER HFF, FLORENCIA and MILAN Product Lines MAN-017-R

Fast Track Troubleshooting

User s Manual

SERVICE MANUAL MUZ-D30NA / - MUZ-D36NA / - MUY-D30NA / - MUY-D36NA / - OUTDOOR UNIT. No. OBH502. Models HFC. Revision E: REVISED EDITION-E R410A

Product Information and Technical Guide

-30 C Undercounter Plasma Freezer

MFM-9TP MFM-9TPW INSTRUCTION MANUAL. Microwave Oven TABLE OF CONTENTS

Northwest RV Supply Manual Compliments of Printed From 900 & 9100 Series

KM-61BAH KM-101BAH KM-151BAH

Portable Refrigerator

Norcold Repair Guide for Ice Maker

Motion Sensor Oscillating Heater with Digital Control

Installation Instructions

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to oven before servicing, unless testing requires it.

Transcription:

Bottom Mount Refrigerator Technical Information AFI2538AE* AFI 2538AE*0, MFI2568AE* MFI2568AE*0! CAUTION Due to a possibility of personal injury or property damage, always contact an authorized technician for service or repair of this refrigerator. All safety information must be followed as provided in Service Manual 16025629. To avoid risk of electrical shock that can cause death or severe personal injury, disconnect unit from power before servicing unless testing is required. Discharge capacitors through a 10,000 ohm resistor before handling. Wires removed during disassembly must be replaced on correct terminals to ensure proper grounding and polarization. Kw/24 hr ±0.4 No-Load Performance, Controls in Normal Position Percent Run Time ±10% Cycles/24 hr ±25% Refrigerator Center Compartment Average Food Temperature ±3 F Freezer Compartment Average Food Temperature ±3 F Ice Maker Compartment Average Temperature ±5 F Ambient F 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 70 90 110 25 cu ft 1.2 2.0 2.6 38 55 80 25 22 15 38 38 38 0 0 0 15 15 15 Evaporator Outlet ±3 F Evaporator Inlet ±3 F Temperature Relationship Test Chart Suction Line ±7 F Average Total Wattage ±10% Suction Pressure ±2 PSIG Head Pressure ± 5 PSIG Ambient F 70 90 70 90 70 90 70 90 70 90 70 90 25 cu ft -20-17 -20-17 85 105 145 150 0 0 83 135 Schematic December 2005 1 16026830

Component Specifications Component Compressor run capacitor Specifications all parts 115VAC/60HZ unless noted Volt... Capacitance... Compressor BTUH... Watt... Current Lock rotor... Current Full load... Resistance Run windings... Resistance Start windings... Electric damper control Maximum closing time... Temperature Rating... RPM... Thermistor Condenser motor Evaporator fan motor Temperature 77 F... 36 F... 0 F... Rotation (facing end opposite shaft) RPM Watt... Current... Rotation (facing end opposite shaft) RPM Watt. Note: Fan blade must be fully seated on shaft to achieve proper airflow. Overload/Relay Ult. trip amps @ 158 F (70 C)... Close temperature... Open temperature... Short time trip (seconds)... Short time trip (amps @77 F (25 C).. Thermostat (Defrost) Volt... Watt... Current... Resistance across terminals: Above 42 F ±5... Below 12 F ±7... Evaporator heater Volt... Wattage... Resistance... 220 VAC 15 µfd ± 10% 730 BTUH 60 Hz / 153 watts 19.0 amps± 15% 1.09 amps± 15% 3.33 ohms± 15% 4.28 ohms± 15% 12 seconds 20 F- 110 F 1 Resistance 10,000 ohms± 1.8% 29,500 ohms± 1.0% 86,300 ohms± 1.8% Clockwise 1120 RPM 3.4 watts±15%@115vac 0.085 amps± 15%@115VAC Clockwise 3300 RPM 4.5 ±15% watts@12 VDC 2.40 amps± 15% 142 F ±9 284 F ±9 17 seconds ±5 12 amps ±2amps 120/240 VAC 495 watts 5.8/3.75 amps 56 K ohms Open Closed 115 VAC 470 ±5% watts @ 115VAC 29 ±5% ohms Control board Volt... 120VAC, 60 HZ See Control board troubleshooting section Dual Water Valve Watts... Blue side 35w,Yellow side 20w Ice Box Fan Light switch Rotation (facing end opposite shaft) RPM Watt. Note: Fan blade must be fully seated on shaft to achieve proper airflow. Type.. Volt Current.. Clockwise 3300 RPM 4.5 ±15% watts@12 VDC SPDT NO/NC 125/250 VAC 5.0 amps 16026830 2 December 2005

Programming Mode: NOTE: The Program Code is located on the Serial Plate on this unit after the word Code. 1. Press and hold the Keypad. 2. Press and hold Freezer Temperature Down Keypad. 3. Release the Keypad and wait 3 seconds. 4. The control will display PE to indicate the programming mode. PE 5. Entry is confirmed by pressing the Freezer Temperature Down Keypad once more. 6. The control will display the current Program CODE. This value should be validated with the Program CODE printed on the unit serial plate. PE0 000 NOTE: If the Program CODE is correct, the Programming Mode is exited by pressing Keypad for 3 seconds. 7. Press the Refrigerator Temperature UP Keypad or Refrigerator Down Keypad to change the digit value with each key press. 8. The decimal point indicates the selected digit. Press the Freezer Temperature UP Keypad to select the next digit. 9. Once the desired Program CODE is entered, press and hold the Freezer Temperature DOWN Keypad until the Program CODE begins flashing indicating it has been saved. NOTE: If you attempt to enter an invalid Program CODE the control will not save the new code, but will beep. (The unit will NOT run with a Program CODE of 0000).Once the Program CODE has been saved the Programming Mode is exited by pressing any key. If the new code is incorrect this process should be repeated. The Programming mode can be exited at any time by pressing key for 3 seconds or will exit if unattended for four minutes. December 2005 3 16026830

Defrost Operation: The Control Board adapts the compressor run time between defrosts to achieve optimum defrost intervals by monitoring the length of time the defrost heater is on. After initial power up, defrost interval is 4 hours compressor run time. Defrost occurs immediately after the 4 hours. Forced Defrost Mode: The forced defrost function is performed using the Freezer display and Refrigerator keypad. Enter the Forced Defrost Mode by performing the following sequence of events: 1. Press and hold the Keypad. 2. Press and hold Refrigerator Temperature Down Keypad. 3. Release the Keypad and wait 3 seconds. Fd appears in Freezer display. Fd 4. Press the Refrigerator Down Keypad again. Sh appears in right display. 5. Press again to force defrost. Fd and Sh will flash in display indicating unit is in defrost. Service Test Mode: The service test functions are performed using the refrigerator display and keypad. Enter the Service Test Mode by performing the following sequence of events: 1. Press and hold the Keypad. 2. Press and hold Refrigerator Temperature UP Keypad. 3. Release the Keypad and wait 3 seconds. 4. The Freezer display will display SE confirming entry in the Service Mode. 5. Press the Refrigerator UP Keypad again to confirm entry in the Service Mode. 6. Display will show 101 in left display and numeric or dashes in right display. 7. Press Freezer Up Keypad and Freezer Down Keypad to toggle through Service Test numbers. Service Test 101 Defrost Heater & Defrost Circuit Press the Refrigerator Up keypad and Refrigerator Down keypad to energize or de-energize the Defrost circuit. The display will read OFF when de-energized, OP when energized with open defrost thermostat and CL when energized with closed defrost thermostat. Service Test 102 Compressor / Condenser Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Compressor/Condenser fan On and Off.. 16026830 4 December 2005

Service Test 112 Freezer Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Freezer Fan On High speed, Low speed and Off. NOTE: Freezer display will show state 0.0 for OFF, 11.0-14.0 volts for High speed or 7.75-8.25 volts for Low speed. Service Test 113 Ice Compartment Fan Press the Refrigerator Up keypad and Refrigerator Down keypad to toggle Ice compartment Fan On High speed, Low speed and Off. NOTE: Freezer display will show state 0.0 for OFF, 11.0-14.0 volts for High speed or 7.75-8.25 volts for Low speed. Service Test 121 Damper Operation Press the Refrigerator Up keypad and Down keypad to toggle Damper (OP) open and (CL) closed. NOTE: If damper is opening or closing it will not allow you to toggle damper and will beep. Display will show state CL or OP if Damper is in the process of closing or opening. Service Test 131 Mullion Heater Press the Refrigerator Up Keypad and Refrigerator Down Keypad to toggle Mullion Heater Off and On. Service Test 141 Fresh Food Thermistor Will Show Fresh Food Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 142 Freezer Thermistor Will Show Freezer Temperature or OP for open thermistor or SH for shorted thermistor. Service Test 144 Ambient Thermistor Will Show AmbientTemperature or OP open thermistor or SH shorted thermistor. Service Test 145 Ice Box Thermistor Will Show Ice BoxTemperature or OP open thermistor or SH shorted thermistor. Service Test 151 Fresh Food State Will show state of Fresh Food. OP (open) CL (closed). NOTE: By pushing either fresh food door switches you can toggle state from OP (open) to CL (closed). Service Test 152 Freezer Food State Will show state of Freezer. OP (open) CL (closed). NOTE: By pushing freezer door switch you can toggle state from OP (open) to CL (closed). Service Test 153 Disable Internal Lights Press the Refrigerator Up keypad and Down keypad to toggle Enable (En) and Disable (dis) internal. December 2005 5 16026830

Service Test 161 Cube Dispenser Display shows the state of the Ice Auger Motor (ON or OFF). NOTE: By pushing Actuator pad you can control state of the Ice Auger Motor without opening Ice Chute door. Service Test 163 Water Dispenser Display shows the state of the Water Dispenser Valve (ON or OFF). NOTE: By pushing Actuator pad or Front fill you can control state of Water Dispenser Valve. Service Test 164 External Ice Chute Display shows the state of the External Ice Chute CL (closed) or OP (open). NOTE: By pushing Actuator pad you can control state of External Ice Chute. Service Test 165 Dispenser Lamp Display shows the state of the Dispenser Lamp (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can control state of dispenser lamp. Service Test 166 Internal Ice Chute Operation Display shows the state of the Internal Ice Chute CL (closed) or OP (open). NOTE: By pushing Actuator pad you can control state of Internal Ice Chute. Service Test 167 Cavity Heater Test Display shows the state of the Cavity Heater (ON or OFF). Service Test 171 Actuator Pad Display shows the state of the Actuator Pad (ON or OFF). Service Test 172 Bottle Fill Display shows the state of the Bottle Fill (ON or OFF). Service Test 173 Ambient Light Display shows light sensor measurement (Hi or Lo). Night light will turn on when light sensor measures Lo. By changing the sensor s exposure to ambient light you can control the sensor measurement. Service Test 175 Dispenser Line Display shows the state of the Dispenser Line (ON or OFF). NOTE: By pushing Actuator pad or Bottle fill you can change state of Dispenser Line. Service Test 182 LED Indicator Operation Press the Refrigerator Up Keypad to show operation of LED Indicators. All LED Indicators will flash. Press twice and LED will stop flashing. Service Test 183 Keypad Operation Display shows a numeric or letter display indicating the last key pressed. NOTE: Refrigerator Up/Down keypads have no effect when pressed and Freezer Up/Down keypads remain operational. 16026830 6 December 2005

Service Test 192 Ice Maker State Test Display shows the status of the Ice Maker and the Heater (ON or OFF). When left Fresh Food door is open the Ice Maker cannot be energized, the test will display dr indicating an open Fresh Food door. When the Ice Maker heater is on, the test will display OnH. Service Test 201 Mullion Heater Override Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change Mullion Heater from cycling on with compressor (Off position) to 100% operation (On Position). Service Test 202 Default Defrost Operation Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change Defrost Operation from normal adaptive defrost (Off position) to minimum time between defrosts (On position). Service Test 203 Show Temperature Set points Press the Refrigerator Up Keypad or Refrigerator Down Keypad to change from showing actual temperature (Off position) to showing temperature set points only (On position). Service Test 211 Fresh Food Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Fresh Food Temperature plus or minus in 1 F increments up to ± 6 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test 212 Freezer Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Freezer Temperature plus or minus 1 F in increments up to ± 6 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test 213 Ice Compartment Temperature Adjustment Press the Refrigerator Up Keypad or Down Keypad to change calibration of Ice Compartment Temperature plus or minus 1 F in increments up to + 0 / + 8 F. NOTE: Temperature will read in Fahrenheit regardless of what current temperature scale is being used. Service Test 221 Reset Default Settings Press the Refrigerator Up Keypad and Down Keypad to force to def (default factory settings). Service Test 231 Water Filter Usage Display shows the percent water filter consumption. 100% indicates the filter should be replaced. Service Test 232 Water Filter Days In Use Display shows the number of days since the filter was installed. Service Test 241 Software Revision Main Control Board Display shows the Software revision of the Main Control Board. Service Test 244 Software Revision Display Board Display shows the Software revision of the Display Board. December 2005 7 16026830

Wiring Diagram 16026830 8 December 2005